THERMOVAC INDUSTRIES CORP

port $2.50,. 3A. " port $2.90. Send for complete information. Dept. AC-5. THERMOVAC INDUSTRIES corp. 41 Decker Street, Copiague, L. I., New York. Circ...
0 downloads 7 Views 373KB Size
NEW PRODUCTS

Tubing Clamps and Plugs are for the birds

the new

13 VAC-VALVES are for Freeze Drying

BEL-ART

The diffractometer shown has an x-ray powder diffraction furnace (Model HX) mounted in position. The x-ray diffraction system including an x-ray generator and control, diffractometer, slit system, detector, and recorder has been designed to provide a simple, compact, versatile, but low-cost instrument. The x-ray generator has output voltage continuously variable from 10 to 45 kv. and output current continuously variable from 0 to 50 ma. The detection system consists of a GeigerMueller argon halogen quenched tube and the recorder is a strip chart potentiometer which is portable. Tem-Pres Research, Inc., William St., State College, Pa. 426

Calorimeter Temperature Controller

vacuum valves that you twist and push to close... twist and pull to open •

Lets you work your system while on vacuum • Lets you connect or disconnect vessels or instruments while on vacuum • Eliminates need for clamps or plugs to open and close vacuum • Is absolutely leak proof and made of natural nonporous rubber

Two sizes: Vi " port $ 2 . 5 0 , %" port $ 2 . 9 0 . Send for complete information.

t5

Dept. A C - 5

T H E R M O V A C INDUSTRIES CORP.

4 1 Decker Street, Copiague, L. I., New York Circle No. 85 on Readers' Service Card

A new Series 2600 automatic temperature control unit is available for bomb calorimeters. This is a complete, thermistor-actuated system consisting of the necessary power supply, bridge circuit, amplifiers, relays, electric water heater and valves for the automatic addition of hot and cold water to adjust and control calorimeter jacket temperatures. Temperature differences as small as 0.001° C. actuate the system to restore the balance. The temperature control unit can be used with Parr adiabatic calorimeters in either new or old installations. Parr Instrument Co., 211 Fifty-third St., Moline, 111. 427

Liquid Chromatograph The Model R-4 is a liquid chromatography assembly consisting of a strip chart recorder, high sensitivity differential refractometer, column mounting bar, and thermostatically controlled water bath all in one integral unit. In addition to its use as a column monitor, the system may be used as a laboratory refractometer for quality control, purity analysis, and blending. Waters Associates, Framingham, Mass. 428

POLYETHYLENE LAB WARE Micro-porous polyethylene now is available in a complete line of filtering apparatus including funnels, extraction thimbles, crucibles, tubes, immersion filters, discs, sheets or special shapes made to order. Manufactured of high density polyethylene, it can be subjected to temperatures up to 250°F. without harm to the porous media. Excellent for use with all bases, acids and salts with the exception of strong oxidizing agents at elevated temperatures. NO solvent will dissolve LABPOR at room temperature. Filtration with LABPOR ware can be done directly on the porous media or by using filter-aid precoat or with paper. See your laboratory supply house. ®Porex Materials Corp.

Described in our new cafalog supplement . . . just off the press! Write Dept. AS for your FREE copy

BEL-ART PRODUCTS PEQUANNOCK, N. J., 07440 OXbow 4-0500

The MOST COMPLETE line of Plastic Laboratory W a r e available from ONE source Circle No. 105 on Readers' Service Card

134 A

·