Visualization of Electrochemical Reactions in Battery Materials with X

Mar 21, 2017 - Many recent insights into battery materials have been achieved through the ...... mirroring coin cell conditions.37,39 Even more sophis...
0 downloads 0 Views 9MB Size
Subscriber access provided by University of Florida | Smathers Libraries

Perspective

Visualization of electrochemical reactions in battery materials with X-ray microscopy and mapping Mark Wolf, Brian M. May, and Jordi Cabana Chem. Mater., Just Accepted Manuscript • Publication Date (Web): 21 Mar 2017 Downloaded from http://pubs.acs.org on March 21, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Chemistry of Materials is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

Visualization of Electrochemical Reactions in Battery Materials with X-ray Microscopy and Mapping Mark Wolf, Brian M. May, and Jordi Cabana∗ Department of Chemistry, University of Illinois at Chicago, Chicago IL E-mail: [email protected]

Abstract Unlocking the full performance capabilities of battery materials will require a thorough understanding of the underlying electrochemical mechanisms at a variety of length scales. A broad arsenal of X-ray microscopy and mapping techniques is now available to probe these processes down to the nano-scale. The tunable nature of X-ray sources allows for the extraction of chemical states through spectromicroscopy. The addition of phase contrast imaging can retrieve the complex-valued refraction of the material, giving an even more nuanced chemical picture. Tomography and coherent Bragg diffraction imaging provide a reconstructed three-dimensional volume of the specimen, as well as internal strain information from the latter. Many recent insights into battery materials have been achieved through the creative use of these, and similar, methods. Experiments performed while the battery is being actively cycled reveal behavior that differs significantly from what is observed at equilibrium and meta-stable conditions. Planned improvements to X-ray source brightness and coherence will extend these techniques by alleviating the current trade-off in time, chemical and spatial resolution.

1

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Introduction Beyond the visible consumer electronics applications, energy storage plays a critical role in areas such as manufacturing, transportation and electricity generation. By some estimates, US industries lose $80 billion each year due to power interruptions, while annual electric vehicle sales are seeing large and consistent increases. 1 Additionally, if renewables are to become the main source of energy production, we will need storage solutions to deal with their intermittent nature. Even with coal and natural gas, fluctuations in demand require that more expensive “peaker plants” be brought online, which could be alleviated if energy from base-load plants can be stored when demand is low. The cheapest energy storage methods, pumped-hydro and compressed-air, are severely limited by the availability of suitable locations. Currently, batteries hold much promise as portable energy storage systems. Batteries contain two electrodes, sites where oxidation and reduction reactions (redox) take place. 2 The fundamental redox chemistry within batteries is non-trivial and governs the practical aspects that are felt by the consumer, such as capacity, cycle life, and power, among others. Therefore, advances in battery technology that yield cheaper, more reliable and better performing systems will result in large economic, environmental and geopolitical benefits. A key requirement for achieving this goal is a better understanding of the chemistry underlying these materials, in order to operate as close as possible to their theoretical limits. Measuring chemical properties with spatial resolution provides a view of the underlying mechanisms that is not available by looking at bulk properties. Electrodes generally adopt a hierarchical structure wherein single crystallites of a redox-active material combine to form agglomerate particles, which are then combined with conductive additives and flexible polymeric binders into a thick (ideally, above 100 µm), porous electrode architecture (figure 1) where different distributions of components and particle sizes are likely to exist throughout the electrode, demonstrated in figure 2. In addition, the thickness of the electrode introduces asymmetries in the transport of ions (from the electrolyte) and electrons (from the current collector, figure 2), which are both required in order for the redox reaction to proceed. As a 2

ACS Paragon Plus Environment

Page 2 of 50

Page 3 of 50

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Page 4 of 50

Page 5 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

X-rays are able to probe various length scales using a variety of contrast mechanisms. Compared to electron microscopy, another common tool for achieving spatially resolved information from cathode materials, X-rays are significantly less damaging to the material under most circumstances. Additionally, transmission electron microscopy (TEM) in particular has stringent requirements for sample thickness, often below 100 nm. In contrast, the ability to tune the X-ray energies offers flexibility in terms of the ability to measure large objects. This Perspective focuses on the use of X-ray techniques as a means to collect chemical information over various time and length scales. It is biased toward techniques that have already seen applicability in battery science. In other words, it is not meant to be an exhaustive review of all X-ray imaging and mapping techniques that may be available. Readers interested in such reviews are referred to several papers in the peer-reviewed literature. 6–9

Foreword: Definition of Resolution Before exploring in detail the different techniques of interest, it is important to define a framework which guides the design of any imaging experiment. This framework is based on the fact that the objective of any chemical imaging experiment is to achieve the maximum resolution along three parameters: space, chemistry and time (as illustrated in figure 3). Because advances in spatial resolution are desirable in order to achieve the ultimate objective of visualizing atomic structures, this parameter tends to be the focus of the attention of researchers developing these techniques. However, as will become apparent throughout this perspective, the deepest level of insight into the electrochemical reactions that determine battery function requires a thorough detection of different chemical states that may often present similar signals, all while operating under an electrochemical stimulus. The latter necessarily implies the importance of temporal resolution so as to acquire multiple data points along the reaction pathway, which may be as fast as seconds. Advances are still needed that push the three parameters forward at the same time. Instead, the current

5

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Page 6 of 50

Page 7 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

The X-ray Imaging Experiment X-ray Sources X-ray generation is possible by two different means: laboratory sources and synchrotron facilities. The general concept of the lab source is based on tubes under vacuum, containing a cathode that is biased so as to generate and accelerate electrons. These electrons collide with the metallic anode, generating X-rays over a narrow range of wavelengths. The specific wavelengths of the resultant X-rays are dependent on the metal used for the anode. Common laboratory X-ray sources include the sealed X-ray tube and rotating anode generator, which differ on the level of vacuum, seal and the arrangement of the metallic anode. 11 Synchrotron radiation is also generated from accelerating charged particles, but provides higher intensity and better coherence than is currently possible with laboratory sources. Unlike laboratory sources, which are broadly available, synchrotrons require very large areal footprints and, thus, are part of central facilities that are open to users worldwide through a competitive proposal system. The particles, typically electrons, are first accelerated to relativistic speeds, at which point they enter the storage ring of the synchrotron. Beamlines are built tangential to the storage ring so as to utilize X-ray radiation generated when the particles are subjected to centripetal acceleration, either through bending magnets or insertion devices, such as wigglers and undulators. Bending magnets serve two purposes. First, they are placed in such a way that the charged particles in the storage ring are redirected to maintain a proper pathway. Second, each redirection generates X-rays, which are then used in experimental stations. Insertion devices are specialized for generating X-rays and differ from bending magnets in that they are straight sections of the ring that have alternating magnetic fields. Charged particles oscillate through the device, with each oscillation essentially equivalent to a single bending magnet. Therefore, the generated photons can reach higher energies than those generated by bending magnets. 12 An important distinction between laboratory X-ray sources and synchrotron sources is the

7

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

nature of the X-rays produced. Synchrotron light sources can generate X-rays at much higher intensity than laboratory sources. Another major difference between laboratory sources and synchrotron sources is that the optics within a synchrotron create a tunable polychromatic X-ray beam, which can subsequently be set to a narrow energy range through the use of monochromators upstream from the end station. In contrast, laboratory sources only produce a limited range of X-ray energies, which is non-trivial to tune. While some techniques fully utilize the white beam, 13 it is more common to select a single desired wavelength and change it during the experiment. Different energy regimes are defined in the X-ray community. Typically, X-rays with energies below ∼2000 eV are termed “soft”, whereas beamlines operating in the “hard” X-ray regime achieve values above ∼4000 eV. The intermediate regime between “soft” and “hard” is often termed “tender”. The high intensity, brightness and tunability render synchrotrons as the preferred light sources for chemical imaging.

Methods of X-ray Microscopy There are two general modes of X-ray microscopy: full-field and scanning (as illustrated in figure 4). The operation of a full-field X-ray microscope is similar to a conventional visible light microscope. In a full-field microscope, the X-ray beam is first focused down to a few microns. This microbeam illuminates the sample, generating a large field of view. The resulting photons are magnified by a second set of optics before reaching the detector. In this mode, the limit in spatial resolution is set by the detector pixel size and any aberrations in the optics. This method results in large images with fine resolution in a single shot. In contrast, a scanning microscope is based on focusing the beam prior to illuminating the sample. In order to collect frames of view that are larger than the illuminated spot, the beam is subsequently rastered over the region of interest in the sample. In this case, the spatial resolution is determined by the combination of beam and scanning step size. Given the different methods of operation, it can easily be concluded that full-field imaging offers higher image throughput than scanning imaging at the highest possible setting. On the 8

ACS Paragon Plus Environment

Page 8 of 50

Page 9 of 50

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

of these images to a three-dimensional volume. This technique is agnostic regarding the contrast mechanism by which the two-dimensional projections were created, meaning it can be combined with any X-ray microscopy contrast mechanism discussed here. Provided the methodology involves the measurement of transmitted photons, tomography allows for the effects of sample thickness to be removed so that the intensity of each voxel is dependent only on material composition. Since the sample is rotating, precise alignment of the rotation axis is necessary to keep the sample in view.

X-ray Optics All the techniques discussed here require at least some level of focusing of the X-ray beam prior to, and, in some cases, also after, interaction with the sample. The ability to obtain images at increasing spatial resolution is dependent on the type, sophistication and quality of the focusing optics. Compound refractive lenses (CRL) use several lenses in series to focus an X-ray beam. CRLs are made of low atomic number materials to reduce X-ray absorption. 14 Reflective optics are used as well for X-ray focusing. First proposed by Kirkpatrick and Baez in 1948, one common setup is the use of two grazing incidence reflective mirrors that are orthogonal to one another (KB mirrors). This setup allows for the incoming X-ray beam to be focused in both dimensions. Both CRLs and KB mirrors are typically used for hard X-rays. 15 Diffractive optics are an alternative option. They are predominant in the soft X-ray regime, but are also compatible with hard X-ray radiation. Fresnel zone plates (FZP) utilize several concentric rings of alternating opaque and transparent zones, decreasing in width as a function of distance from the center. In this way, the diffracted X-rays from the transparent sections of the optic will undergo constructive interference, focusing to a point. The maximum amount that the beam can be focused is inversely related to the width of the outermost ring. Multi-layer Laue lenses (MLL) are similar to FZPs, in that they use zones to achieve focusing. However, MLLs use one-dimensional zones rather than rings. Because of 10

ACS Paragon Plus Environment

Page 10 of 50

Page 11 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

this, they can be synthesized using thin film deposition, which allows for smaller thicknesses than current lithographic techniques. 12,16 Modern focusing optics typically limit the spatial resolution of the measurement to roughly 10 nm, with MLLs. 17 Focusing optics have an inherent disadvantage that the resultant spatial resolution is dependent on the optic itself. Lensless techniques remove this restriction. Coherent diffraction patterns may be collected and processed using an iterative reconstruction method to produce an image. Thus, the ultimate limit resides in the wavelength of the incoming radiation, also known as the diffraction limit, meaning that spatial resolutions can be achieved that are smaller than the size of the beam on the sample and the nominal resolution of the optics. Techniques derived from this approach are further discussed below.

Detectors In full-field microscopy, the magnified X-ray image strikes a scintillator where it is converted to visible light. The total energy of this conversion must be conserved, so one high-energy X-ray photon results in hundreds of low-energy visible light photons. This light is then magnified using visible-light microscopy optics onto a detector, usually a charge-coupled device (CCD). Any defects in the scintillator are clearly visible in the resulting intensity images so it is important to collect a reference frame to remove these features. For scanning microscopy, no post-sample optics are required. Instead, a detector measures the transmitted intensity at each raster position. Photomultiplier tubes (PMTs) have a large collection area, low noise and high gain, making them ideal for this application. In some specific scanning microscopy methods, a two-dimensional interference pattern is needed at each raster position, so a CCD detector is used instead. The dynamic range of the detector is an important factor to consider. CCDs work by exposing a photo-active layer to radiation, which then results in charge accumulation in the underlying structure, to be read out after some time interval. If a single CCD pixel becomes 11

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

saturated before being read, the area will have artificially low values in the resulting optical depth image. Shortening exposure time can solve this problem, however the resulting data will have a lower signal-to-noise ratio. A simple solution is to keep the exposure time short and then collect and average multiple frames. In the specific case of imaging techniques relying on diffracted X-rays (see below), 2dimensional area detectors are common. These detectors capture a two-dimensional segment of the full 3D pattern (also known as the Ewald diffraction sphere). Any crystallites whose orientation produces diffraction vectors landing within this segment will be detected. The exact range depends on the geometry of the experimental setup and the wavelength of radiation used; high energy X-rays cause more diffraction conditions to be detectable in a given area. A 1-dimensional pattern can then be obtained by integrating around the resulting diffraction rings.

Mechanisms of Chemical Contrast Spectromicroscopy X-ray microscopy utilizes a multitude of contrast mechanisms. Absorption contrast relies on the intensity of the X-rays that penetrate through the material being imaged. From the physical perspective, it involves detecting changes in the amplitude of the incoming Xray wave after interacting with the sample, most commonly after transmission. Thickness and composition of the material are two major contributing factors to the X-ray absorption. Therefore, through the collection of one signal, both morphological and chemical information can be generated. Since X-ray absorbance depends on interaction with electrons, elements with higher atomic numbers have a higher absorbance. Once the X-ray energy exceeds that needed to promote a core electron in an element present in the sample, a sharp increase in X-ray absorbance is seen, known as an “edge”. Therefore, the specific energy value of the transition is indicative of the element and its chemical state (eg. formal valence state). Each 12

ACS Paragon Plus Environment

Page 12 of 50

Page 13 of 50

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

the energy is scanned below and through the edge, fluorescence detectors can also be used to produce X-ray absorption spectra, in a manner that is compatible with spectromicroscopy. This approach was recently demonstrated in battery materials. 19 Phase contrast imaging is an alternative to absorbance: the changes of the observed phase of X-ray waves, as opposed to their amplitude, are monitored. These changes are observed as the thickness/density of the sample changes. In order to resolve the differences in the phase shift, δ, the detector is generally placed far behind the sample. Phase contrast imaging is advantageous as it is more sensitive than absorption contrast, and can therefore utilize lower X-ray intensities. For this reason, phase contrast is often used to study materials that do not absorb strongly or that are sensitive to radiation damage. A drawback for some, phase contrast imaging heavily relies upon a highly coherent X-ray source, as well as a sophisticated detector. A complex-valued refraction spectrum can be acquired using phase contrast by collecting data over a range of energy points. This information will also be dependent on the electronic structure of the sample, but, due to its complexity, this method of spectromicroscopy remains under development. 20 In spectromicroscopy, whether full-field or scanning, the same field-of-view is imaged repeatedly while the energy of the incident beam is changed over an absorption edge of the element(s) of interest. The resulting frame-stack provides a full absorbance and/or phase spectrum at each pixel. These spectra are then processed into a scientifically meaningful quantity to generate chemical maps of the field-of-view. In order for pixel-wise spectroscopic conclusions to be valid, it is critical that the images be properly aligned with one another, which is rarely the case with raw data-sets. The next step in the analysis involves normalization of the spectra relative to the background optical depth. As X-ray energy increases, the transmission of all materials increases as well. Correcting for this effect improves the reliability of analysis methods that involve decomposing the spectra into components of known materials. 21 Conversion of the resulting absorbance spectra to some figure of scientific merit depends

14

ACS Paragon Plus Environment

Page 14 of 50

Page 15 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

in large part on the question being addressed by the experiment. A common goal is to map the distribution of certain elements. This goal can be accomplished by collecting two frames per element: one above and one below the absorption K-edge. By comparing these “edgejump” values for the elements in question, their relative concentrations can be calculated. 22 Alternatively, generating spectroscopic maps involves reshaping the data to give an array of spectra, each one corresponding to a pixel in the final map. This outcome is accomplished by “looking through” a frame-set along the energy dimension and flattening along the image dimensions, as illustrated in figure 5. In theory, any analysis that is performed on a bulk spectrum can be done on a single-pixel spectrum. In practice, there are generally a lot of spectra to be analyzed; a set of 1024 × 1024 frames contains over 1 million spectra to be processed. This situation means that analysis cannot rely on human intervention. If prior knowledge of the presence and distinct spectra of multiple phases in the data-set is available, their signals can be decomposed. 10,23,24 If the component spectra are not known, which is often the case, a variety of signal processing techniques, such as independent components analysis (ICA) 25 or Bayesian methods, 26 can be used to approximate them and extract the relative proportions of each component. 27,28 Care must be taken, however, since many of these methods assume properties of the data that are not necessarily true. Principal components analysis is a common alternative to ICA that has seen application in spectromicroscopy of battery materials. 10,29 Another approach involves the use of numerical methods to directly map some property of the spectrum. This approach is most effective if an argument can be made that the directly calculated value correlates strongly with some change in the properties or state of the material. For example, the oxidation state of nickel in several layered battery cathode materials is accompanied by a shift in the edge and whiteline positions of the corresponding K-edge spectrum to higher energies; 30 extracting and mapping the whiteline position for each pixel’s spectrum can provide a map that approximates the oxidation state of the metal and consequently the state-of-charge of the material. Care must be taken to account for small variations in absorbance across the two or three largest absorbance points which are

15

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

not due to the sample, but background or spurious signals.

Bragg Diffraction Microscopy Bragg X-ray diffraction (XRD) provides complementary information to spectroscopy. Rather than observing electronic transitions, it provides a measurement of the distance between crystalline planes (d-space) within a material. This crystallographic information means that unit cell parameters, atomic defects, strain and microstructural information of the coherent domains are available. Of particular interest in the context of this discussion is the ability to interpret the unit cell dimensions as a given chemical composition if prior knowledge of the system exists. In order to observe diffraction from a material, the Bragg condition must be satisfied, in which a particular X-ray wavelength, crystal spacing, and orientation must be met. A conventional XRD experiment holds the X-ray wavelength constant, while altering the incident and detected beam angles. In contrast, energy dispersive X-ray diffraction (EDXRD) holds the orientation constant and varies the wavelength. As a result, no goniometer is required and the variation in wavelength can be used to profile the depth of the sample, but extracting physical quantities from the resulting data is less straightforward. 31,32 Once a diffraction pattern is obtained, crystallographic parameters can be extracted and used for mapping. The data generated in Bragg diffraction microscopy experiments can be treated very similarly to those collected during spectromicroscopy. Each mapping position is equivalent to a pixel in an X-ray micrograph and a series of frames are collected at different scattering vectors, q. Generally, the spatial dimensions are the slowest-changing in diffraction mapping, whereas they are the fastest (or even simultaneous) in microscopy; this distinction does not change the structure of the data in a significant way. However, it does obviate the need to align each image. Rather than a full absorbance spectrum at each location, these experiments generate a diffractogram at each position. Theoretically, a researcher can analyze the two-dimensional diffraction pattern at each position; often, the 2D patterns are integrated to form the more traditional 1D diffractograms. From here, a refinement can 16

ACS Paragon Plus Environment

Page 16 of 50

Page 17 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

retrieve crystallographic parameters, such as unit-cell dimensions, strain or phase ratios.

The Ultimate Frontier: The Lensless Microscope Phase contrast and Bragg diffraction are combined in coherent diffractive imaging (CDI). A single particle fulfilling the Bragg condition is illuminated by a coherent X-ray beam that is larger than the particle. The detector is placed far away from the sample, so that it can collect fringes of the diffracted beam. An iterative algorithm is used to reconstruct an image from the phase information in the fringes of a three-dimensional diffraction pattern. 33 This methodology decouples spatial resolution from the characteristics of any focusing optics used. In other words, as a lensless technique, the process of generation of images does not suffer from lens aberration and thus allows for very high spatial resolution approaching the diffraction limit, under 10 nm in some cases. Ptychography is another lensless technique which also relies on collecting the full diffraction pattern using coherent diffraction. Unlike CDI, this is a scanning technique; small spots are collected in such a fashion that they spatially overlap on the sample. Similar to CDI, ptychography utilizes an iterative algorithm to reconstruct an image from the diffraction patterns. As a result, the ultimate spatial resolution is, to a large extent, independent from the size of the beam used to collect the overlapping patterns. Artifacts from the reconstruction process sometimes manifest as high frequency bands alongside sharp edges in the specimen. Since this technique is driven by an interference pattern, the best reconstructions are obtained from strongly scattering materials. Ptychography has also been performed in tomographic mode, 34 but this methodological area is still in its infancy. As an added bonus, the reconstruction produces both the real and imaginary components of the object image. By comparison to an area with no material, the fully complex refractive index can be calculated. Exploiting the complex-valued nature of this technique is a relatively unexplored area.

17

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Page 18 of 50

Page 19 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

Visualization and Colormaps Turning a large data-set into a two-dimensional image is a task of increasing difficulty as the number of dimensions increases. For applications with two spatial dimensions, images are generated by data-reduction as described in the preceding sections. The relationship between values and colors is known as a “colormap” or “lookup table”. The choice of colormap can have subtle effects on how the data are interpreted. In general, human vision associates the brightness of a color with the value it represents, regardless of its hue. Therefore, an effective colormap translates high values to high-brightness colors and low values to lowbrightness colors. Rainbow colormaps, such as jet, do not meet this criterion and should be avoided for representing sequential data. Jet contains bands of high and low brightness that are perceived as sharp gradients in the data that do not actually exist. Perceptually uniform colormaps, such as viridis for Matplotlib and parula for Matlab, are designed to avoid this problem. Additionally, viridis was tested against color blindness and ensures that data display properly to people in this category. Projecting data with three spatial dimensions onto a two-dimensional canvas can be done with any one of several visualization tools. Typically, certain features in the data are of interest, such as internal fractures within particles or the distribution of certain elements. Successful visualization usually requires additional analysis steps that identify and highlight these features while making the surrounding material partially transparent. Avizo (FEI) is a popular commercial software package specifically designed to work with tomography data: it contains a number of filters that allow the data analysis to be performed within one piece of software. An additional Avizo package can be purchased that allows it to handle data-sets that do not fit entirely into main memory, which is often the case for tomography. An alternative is Paraview (Kitware Inc. and Los Alamos National Lab), a general purpose visualization platform that is highly extensible, allowing python plugins to be run from within the application. Paraview has the additional benefit of being free and open source. For quick inspection of tomographic slices, ImageJ provides the Volume Viewer plugin (included in the 19

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

FIJI distribution), which is more straight-forward to use than either Avizo or Paraview, but has fewer features.

Ex situ versus operando To a large extent, electrochemistry is most interesting when away from equilibrium. As electrochemical devices, batteries are useful during operation, which is inherently under kinetic control. While the kinetic states are determined by the thermodynamics of the system, metastability is more prominent under electrochemical conditions than in other classical chemical environments, such as high temperatures. This prominence also implies that the probability of producing kinetic states that are only weakly metastable is high. In fact, the problem of self-discharge, common in certain batteries, is precisely the product of equilibration of a metastable charged state. As a consequence of the pervasive kinetic control, ex situ measurements, which rely on harvesting samples from a cell at a desired chemical state, introduce uncertainty when the goal is to describe relevant states under working conditions. Nonetheless, if caution is applied, and due to their simplicity, these measurements can still provide valuable guidance, 24 mainly because they do not critically suffer from constraints in measurement time and, thus, can result in the highest data quality. Ultimately, operando measurements of battery reactions are preferred because of the growing body of evidence showing that there are many cases where the state within an operating battery is different from what is observed once the cell is disassembled, 35,36 especially when high rates are employed. For this reason, researchers developing novel methods of imaging should have motivation to enter a path that results in means to operando analysis. At this point, given certain confusion in the field, it is worth clarifying that we consider operando measurements to be a small subset of in situ science. The condition sine qua non for an operando experiment is that the cell is not stopped to collect data unless the goal is specifically to measure equilibration phenomena.

20

ACS Paragon Plus Environment

Page 20 of 50

Page 21 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

While operando measurements are preferred and should be pursued, they can present several challenges of varying degrees of difficulty. The setup must allow photons to pass through both the sample and apparatus with very little disturbance to the signal from the apparatus itself. First and foremost, X-ray absorbing materials have to be minimized in order to ensure sufficient signal reaches the detector. Ideally, supporting materials containing heavier elements should be removed, or made sufficiently thin so as to minimize their effects. Another challenge is avoiding X-ray induced damage to supporting materials, such as the polymer binder often used in the construction of cathodes. Maintaining adequate stack pressure may also be important, depending on the nature of the experiment. 37 Additionally, the possibility of deleterious effects of X-ray exposure on the behavior of cathode materials is not completely understood. One possibility is to use very high energy X-rays, which can penetrate the casing material 38 and are less damaging. This strategy is valid for some diffraction experiments, but cannot be applied to spectroscopic imaging since specific energies at which the X-ray beam is absorbed are required. In situations where high-energy X-rays are not possible, a transparent window is necessary. Beryllium is a typical choice, but its use introduces stringent handling requirements due to its high toxicity, especially in the dispersible form that is generated, for instance, during machining. It also oxidizes relatively easily, making it unsuitable for high-voltage battery applications. Silicon nitride is an appealing option since it can be purchased commercially in prefabricated windows down to tens of nanometers in thickness. At these thicknesses, it also does not have any noticeable morphological features, making it suitable for X-ray microscopy techniques. However, they are very fragile due to their thickness. Polyimide (Kapton) film has found widespread use in operando diffraction experiments, despite the fact that it also introduces an amorphous contribution to diffraction patterns. It has relatively high transmissivity, is easy to fabricate and is chemically inert. Unfortunately, it cannot ensure a complete seal and, like many other plastics, it often contains filler particles which are heavy enough to become visible in a microscopy experiment, interfering with

21

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

observations and, thus, rendering it unsuitable. Amorphous carbon can also be used. A large advantage here is its electrical conductivity, which eliminates issues of electrochemical inactivity of the material behind the window. Since it is made entirely of carbon, it also interacts only very weakly with X-rays, so it induces minimal signal attenuation. However, it is difficult to fabricate, and can react under certain conditions, such as at very high potentials or against lithium metal. The AMPIX electrochemical cell, developed by Argonne National Laboratory, is an example of a cell with amorphous carbon windows that fits the requirements of an operando X-ray experiment. The cell design ensures good stack pressure as well as electrical conductivity, closely mirroring coin cell conditions. 37,39 Even more sophisticated cells are needed when using low energy, soft X-rays, where the sample volume must be small to avoid excessive absorption of the signal by the sample. In this case, designs that rely on microfabrication have recently been demonstrated. 36 Operando measurements create the most severe challenges to an imaging experiment when considering the three scales of resolution above, namely spatial, chemical and temporal. Many battery reactions span several hours, but the need to build a reaction pathway means that it is desirable to collect at least 5 data points during the reaction. This goal imposes restrictions on the time available to complete an image containing the desired chemical information, at the desired level of spatial resolution. Unfortunately, all modes of chemical contrast require collecting multiple frames for the same reaction state to reconstruct a map of the species present in the field view. Using XANES microscopy as an example, chemical resolution is achieved by collecting frames at a large number of energies, with the limit being set by the precision of the upstream optics. In the particular case of scanning techniques, spatial resolution requires the use of the smallest possible step size to raster the field of view, meaning that a similar trade-off emerges in that the acquisition time is directly affected by this parameter. Additionally, increasing the collection time for each frame will improve the signal-to-noise ratio and improve the accuracy of the data, again at the expense of longer acquisition times for a full frame-set. In practice, the most common choice is to minimize

22

ACS Paragon Plus Environment

Page 22 of 50

Page 23 of 50

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

the number of points to obtain some level of chemical resolution in the individual frameset, whether scanning energy (spectroscopy) or a beam-sample-detector angle (diffraction). This approach strongly relies on prior knowledge of the chemical species involved during the reaction, so that energies or angles are chosen at which signals between these species differ the most. Such prior knowledge is typically acquired through XAS or XRD measurements of the bulk average, as opposed to spatially resolved regions. In the case of the spectroscopy of transition metal species, a change of one unit in the formal oxidation state translates into a displacement of the signals of a few electron-volts, which renders the method viable. Challenges arise when the changes between species are small, for instance, when compounds exist at redox states intermediate between end members. The strategy also inherently lends itself to misinterpretation if previously unknown or unexpected states form in the measurement, especially if they are related to the known, expected species. The local character of an imaging measurement means that the limit of detection of minority species increases with respect to a data set gathered from the bulk average, especially if they accumulated in specific regions of the image. All in all, it is important to be aware of the compromises made to avoid over-analyzing data. Since the field of X-ray imaging is vibrant and constantly pushing the boundaries in resolution, it is likely that these limitations will be alleviated with time, creating exciting opportunities for rich insight into battery operating conditions.

Applications of X-Ray Imaging to Problems in Battery Research In this section, we describe representative case studies that serve to highlight the power and versatility of X-ray imaging to elucidate phenomena occurring in battery materials. This section is not meant to be exhaustive, mostly focusing on examples of materials for Li-ion battery electrodes, with an emphasis on those containing transition metals. The reason for the choice of Li-ion devices is that they are the most pervasive battery systems in the research 24

ACS Paragon Plus Environment

Page 24 of 50

Page 25 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

literature (aside from being the most commercially relevant), with examples available that fully exploit the current capabilities in X-ray imaging. These capabilities are not dependent on the device, and, thus can be applied to many other battery problems. Indeed, studies of other battery systems with these techniques exist in the literature, exploiting the same features discussed below. For the sake of conciseness, only the chemical identity and a brief mention of the insight gained by the imaging of each electrode material will be presented. For an extensive discussion of the current body of knowledge of electrochemical reactions in the battery materials discussed here, the reader is referred again to reviews available in the peer-reviewed literature. 40,41 Selected applications are grouped by contrast mechanism. X-ray imaging at one or two energies close to an absorption edge can be used to elucidate morphology or elemental distribution respectively. While these approaches can provide highly valuable information, chemical imaging generally provides increased insight.

Morphology Absorption imaging at a single X-ray energy provides a direct look at the internal morphology of the material. The short acquisition times and relatively straightforward technical requirements mean that high temporal resolutions can be achieved. For instance, full-field X-ray microscopy has been used to visualize the fate of the components of a battery during thermal runaway with a time resolution of 800 µs. 42 The result was a high frame-rate movie, with no chemical contrast, showing the initial distortion of electrode layers followed by gas formation and finally the catastrophic structural failure of the cell. Tomography solves a common problem where interpretation of two dimensional imaging data is confounded by the fact that the measured intensity at each position is a projection through the entire specimen. Tomographic imaging of batteries can even be achieved with laboratory X-ray microscopes. 43 The imaging of electrode morphology can reveal useful information regarding electrode performance. For example, the novel use of a heat-transfer model to extract tortuosity and porosity data from three dimensional electrode volumes re25

ACS Paragon Plus Environment

Chemistry of Materials

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

vealed significant anisotropy and heterogeneity in the pore structure, generating unique new inputs for continuum models with the goal to explain and predict electrode behavior. 44 Even when no direct chemical information is obtained, this technique can still illuminate details of the underlying mechanism of electrochemical reaction. In conversion reactions, mixtures of relatively heavy metallic particles and Li2 O are formed. 45 Since the differences in attenuation coefficients of the different species are quite large, quantification of changes in contrast in the image can be used to create pseudo-chemical maps. This approach is relatively fast, since data collection still occurs at only one X-ray energy. The idea was first exploited by Ebner et al. to study the reduction of tin oxide to tin with microscale spatial resolution. A core-shell mechanism was observed, combined with insight into crack initiation and growth. They also compared particle-level volume changes and their relationship to the expansion of the electrode as a whole. They found that the particles expand beyond the tolerance of the supporting matrix, which has implications for the reversibility of the reaction. 46 A similar approach was applied to nanoscale imaging of individual tin oxide particles, generating new details on particle fracturing and pulverization. 47 This single-energy approach to acquiring chemical contrast is only valid for three-dimensional imaging, since, in two-dimensions, the intensity of a given pixel is heavily influenced by the thickness of the sample at that point. Another limitation is that the majority of reactions of interest in batteries involve compounds that do not show significant differences in attenuation coefficient. In these cases, tomographic techniques with chemical contrast are needed.

Elemental Distribution Several experiments highlight the ability of X-ray imaging to track the distributions of specific elements in battery materials. Migration of transition metals after one cycle was seen by X-ray absorption tomography. 48 Specifically, the authors discovered depletion of the transition metals at the surface of the particle, accompanied by manganese segregation. Another example used this technique to track transition metal distribution across multiple cycles in 26

ACS Paragon Plus Environment

Page 26 of 50

Page 27 of 50

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Chemistry of Materials

a particle of mixed transition metal oxide LiNi0.4 Mn0.4 Co0.2 O2 . 49 The authors associated improvements in cycling performance with the existence of an excess of manganese and a depletion of cobalt and nickel at the surface of the particles. The improvement was rationalized through a lower extent of irreversible conversion of nickel-containing layered oxide domains to a reduced rock-salt phase, which is known to be detrimental to charge transfer at the surfaces in these materials. 50

Spectromicroscopy Many of the materials used for battery cathode materials do not show significant changes in absorbance between the various states encountered during operation, limiting the scope of the morphological and elemental-distribution techniques. X-ray absorbance spectroscopy provides a direct measure of the chemical state of individual elements. Therefore, it can be used to track the oxidation state of the electrochemically active species. This approach is not limited to a specific technique: it has proven insightful using hard and soft X-rays, K and L absorbance edges, full-field and scanning microscopes, and in two-dimensional and tomographic imaging modes. Hard X-ray full-field microscopy has seen rather broad applicability to questions in battery research. As an example, it has effectively been demonstrated to locate delithiation domains in olivine-type LiFePO4 microcrystals, and subsequent morphological events, such as fracture, were identified. 29 However, the spatial resolution of a hard TXM, ∼30 nm, did not allow for a specific correlation between chemical domains and fracture points. To achieve this knowledge, soft X-ray absorption spectroscopy coupled with ptychographic microscopy was required in order to gather information at the highest spatial resolution possible today. Yu et al. investigated how crystal size impacts the transformation of LiFePO4 to FePO4 . 24 Chemical maps were successfully produced for particles ranging from