WATER POLLUTION

a platinum resistance thermometer that's portable, accurate, easy to use. ... 0,1°F/digit reading resolution. • optional ... Circle No. 80 on Reade...
4 downloads 0 Views 134KB Size
Report for Analytical Chemists

WHEN IS A "METTLËR" NOT A BALANCE? When it's the Mettler digital thermometer . . . a platinum resistance thermometer that's portable, accurate, easy to use. With features like . . . • all-digital readout from - 4 to + 5 7 5 ° F ( - 2 0 to + 3 0 0 ° C ) , continuous, without range switching • 1 mV/°F recorder output with ± 0 . 1 5 % linearity and full range zero suppression • interchangeable matched platinum resistance sensors • absolute accuracy (including sensor intercharigeability error) from ± 0 . 3 ° F at 32°F to ± . 5 4 ° F at +575°F, ± 0 . 0 5 ° F reproducibility • 0,1°F/digit reading resolution • optional selector switch for six sensors For additional information, write Mettler Instrument Corporation, 20 Nassau Street, Princeton, N.J. 08540

Figure 4. Two types of apparatus for titration utilizing kryptonate as end-point indicator: (a) after Tôlgyessy et al. ( I l ) , (b) after Chleck (17) 1. 2. 3. 4. 5.

Nitrogen supply Regulator and valve Geiger-Muller tube Reaction vessel Buret

6. 7. 8. 9.

Counting cell Proper countsrate meter Flowmeter Magnetic stirrer

other kryptonate chosen. Radioactive kryptonates commonly used in volumetric analysis are listed in Table III.

Mettler Circle No. 80 on Readers' Service Card

Detect, Analyze and Measure

WATER POLLUTION WITH P0LAR0GRAPHY



Table III. Radioactive Kryptonated Indicators Radioactive kryptonate of

Substance, detd.

Titrant soin.

Mg

NaOH

HCI

Zn

NaOH;F"

HCI; Th(N03)4

Ag

Ba2+

K 2 Cr 2 0 7

Agi

Nis+

KCN

Agl03

C a 2 + , Mg 2 +, Sr2+

EDTA

Y2(CA)3

Fe 3 +

EDTA

Glass

2+

2

C a , Cd + T h 4 + , H 2 SOi HCI, HNO3

NaF NaOH

Two types of experimental apparatus for radiometric titrations with radioactive kryptonates as end-point indicators are shown in Figure 4.

®

RIVER SAMPLE NO. 1

SAMPLE

specimen groups

to determine presence or absence of anions such as nitrite, nitrates, sulphate and others.

Polarograph of river water showinq copper, nickel and iron concentration at PPM

I D E T L C T a l m o s t every element in the periodic table — singly, or in multiples. RtVER SAMPLE NO. 2 Anodic -— Stripping polarograph showing zinc, lead, a n t i m o n y and copper at concentrations of less than 100 ΡΡΘ.

Send for booklet:

• M E A S U R E quantités to parts-per-million, or even partsper-billion, with anodic stripping.

free

CHEMTRIX, INC.

POLLUTION & POLAROGRAPHY

Instrument for Science P O BCK 725

Bcaverton, Oregon 9/00·)

(b03l 648 1434

Circle No. 20 on Readers' Service Card

ANALYTICAL CHEMISTRY, VOL. 42, NO. 9, AUGUST 1970 ·

21 A