WILKS CORPORATION - Analytical Chemistry (ACS Publications)

May 23, 2012 - WILKS CORPORATION. Anal. Chem. , 1970, 42 (02), pp 161A–161A. DOI: 10.1021/ac60284a840. Publication Date: February 1970...
0 downloads 0 Views 233KB Size
COME SEE US

IN BOOTHS 933-934 935-936 PITTSBURGH CONFERENCE

QUALITY AT LOW COST! THE MOST ATTRACTIVE

Model H-1200 Hilger & Watts Infragraph

BUY IN INFRARED

SPECTROSCOPY

BEST PRICED IR SPECTROPHOTOMETER The new Hilger & Watts H-1200 Infrared Spectrophotometer, distributed exclusively in the United States by Wilks Scientific is not only the lowest priced instrument of its type available but offers versatility and performance provided only by much higher priced instruments. FASTEST PRODUCTION OF SPECTRA The Infragraph’s outstanding capability of recording complete spectra with excellent resolution and low noise in less than 2 minutes, multiplies the output of useful data. One instrument does the work of several and saves investment for additional equipment. 1 Vz min. polystyrene scan shows spectral quality at high speed comparable to expensive high-performance instruments

BROADER ACCESSORY CAPABILITY Separated sample and reference beam compartments in the Infragraph’s unique optical arrangement increase doublebeam accessory adaptability. The application-oriented and budget-minded investigator will welcome the Infragraph’s accommodation of Wilks Scientific's complete line of standard and special IR accessories. RUGGED AND RELIABLE Rugged construction using quality components and solidstate electronics have produced excellent reliability records for the many instruments already installed in Europe. Service personnel and stocks of spare parts or supplies are available at Wilks Scientific to ensure uninterrupted operation.

Sample- and reference-beam “corner design” offers enhanced freedom of accessory selection

INFRAGRAPH SPECIFICATIONS: Spectral range: 4000 to 650 cm*1 (21/2 to 15.4 microns) Resolution: Better than 5 cm 1 at 1000 cirr1 Abscissa Accuracy: 5 cm 1 from 2000 to 650 crrr1 Repeatability: 2 crrr1 Photometric Accuracy: 2% T Repeatability: 1% T Scanning Speeds: 11/2 to 20 min. continuously variable Pen Response: 1 sec. full scale (noise level less than 1%) Recording System: Flat bed, flow and single charts Chart Presentation: Linear cm1, 9" and 18" abscissa Time Drive: Transmittance recording at constant wavelength Dimensions: 27’/2 x 1711 x 8I/2 inches. Weight: 81 pounds

INFRARED

OUR BUSINESS

IS

XAZ11 IX. Q d WV I I— If Fold-back

covers

and maintenance

permit “fingertip” accessibility for instruction

SOUTH NORWALK TELEPHONE

·

·

SCIENTIFIC CORPORATION

CONNECTICUT (203)638-4537

06856

Circle No. 166 on Readers’ Service Card

ANALYTICAL CHEMISTRY, VOL. 42, NO. 2, FEBRUARY 1970

·

161 A