Accurate Determination of Dew Point - American Chemical Society

Accurate Determination of Dew Point. ARTHUR W. HIXSON AND G. EDWIN WHITE,1 Columbia University, New York, N. Y. The apparatus features sensitive ...
0 downloads 0 Views 821KB Size
ANALYTICAL EDITION

MAY 15, 1938

solved succinic acid; and three 50-ml. portions of cold water. At no time is the funnel that forms the reductor inlet permitted to become entirely empty, and the reductor when idle should always be kept full of distilled water to above the top of the zinc. The solution is cooled to room temperature by addition of several ice cubes prepared from distilled water, transferred to an 800-ml. beaker, and titrated with 0.05 N potassium permanganate solution (1 ml. is equivalent to 0.002323 gram of columbium or 0.002395 gram of titanium) that has been standardized against sodium oxalate from the Bureau of Standards. A "blank" on the reagents and reductor is made by fusing a 0.0500-gram portion of pure titanium dioxide with 2 to 3 grams of potassium pyrosulfate (the same amount used in the analysis), dksolving the melt, and pawing it through the Jones reductor, all as described in the third and fourth paragraphs. The solution is cooled to room temperature and titrated with 0.05 N potassium permanganate. The total volume of standard 0.05 AT potassium permanganate solution required, less the "blank" (including 0.0500 gram of titanium dioxide) is multiplied by 0.002323 and divided by the weight of sample taken to give the per cent of columbium. The weight of columbium found is multiplied by 1.43 to give the corresponding weight of columbium pentoxide. The weight of the total oxides of columbium and tantalum obtained as described in the second paragraph, less the weight of columbium pentoxide found, gives the weight of tantalum pentoxide, which, multiplied by 81.91 and divided by the weight of sample taken, gives the percentage of tantalum in the steel. A modification of this method is necessary for steels containing molybdenum and tungsten. When titanium is present in amounts greater than 0.10 per cent, it is necessary to use the cupferron method described above. If desired, the ignited and weighed precipitate of columbium

235

and tantalum pentoxides, obtained as described in the second paragraph, may be fused with potassium pyrosulfate without any titanium dioxide addition, the melt dissolved as described in the third paragraph, and the solution passed through the reductor, cooled, and titrated, all as described in the fourth and fifth paragraphs of the method. A "blank" in this case is run on the reductor by dissolving 2 to 3 grams of potassium pyrosulfate in 100 ml. of 20 per cent sulfuric acid containing the same amounts of succinic acid and hydrogen peroxide that were used in the analysis, and putting the solution through the reductor as described, cooling, and titrating. It is very difficult to obtain complete reduction of columbium b y means of a Jones reductor (unless titanium is added) but, if the directions given are closely followed, the reduction is so nearly complete that the error thus introduced is not significant when dealing with the amount of columbium usually found in a sample of steel.

Literature Cited (1)

Lundell, Hoffman, and Bright, "Chemical Analysis of Iron and

Steel," New York, John Wiley & Sons, 1931. (2) Schoeller and Powell, Analyst, 53, 264 (19223). (3) Silverman, IND.E m . CHEX, Anal. Ed., 6, 287 (1934). (4) Weiss and Landecker, Chern. News, 101, 2, 13, 25 (1910). RECEIYEDFebruary 4, 1938. Presented in part before the Division of Phyeical and Inorganic Chemistry, American Chemical Society. Second Annual Symposium on t h e Less Familiar Elements. Cleveland, Ohio, December 27 t o 29, 1937.

Accurate Determination of Dew Point ARTHLX W. HIXSON

AND

G . EDWIN WHITE,' Columbia University, New York, N. Y.

The apparatus features sensitive instrumental observation of dew, combined with minimization of systematic errors in the measurement of the temperature at the gas-liquid interface. The technic is such as to eliminate the marked hysteresis error characteristic of methods involving continuous temperature change. An accuracy of kO.0lo C. is reached. A double gaseous film adjacent to the liquid phase is hypothesized in explanation of observed phenomena.

D

I R E C T dew-point determination affords a sensitive means of determining vapor concentrations. The formation of dew has been utilized as a criterion in the investigation of phase equilibria with reference to motor fuels (2, 6, 12) and hydrocarbon systems under pressure (8, 9). Improvement in the accuracy of dew-point indication should increme its usefulness as a research tool. Reviews of hygrometric methods (IO,11) indicate that the meacs of dew-point determination used in 1916 offered little advantage in dependability over the ether-cooled silver thimble of Regnault ( 7 ) . The accuracy of preferred forms of apparatus varied from 0.2" t o 2" C. with decrease in relative humidity. I

Present address, College of the City of New York, New York, N. Y.

It appears that these errors were due largely to the unmeasured temperature gradient between the gas-liquid interface and the temperature-recording device. This temperature gradient has two components: (1) the drop across the dew itself, and (2) the drop within the apparatus. Griffiths (1) reduced the second component by inserting the thermometer in a metal block upon whose surface the dew deposited. Readings at appearance and disappearance of dew differed by 0.1" t o 2.2" C. Holtzmann (5)accomplished virtual elimination of the second component by use of a thermocouple mounted close to the metal deposition surface. An ingenious technic of observation yielded a precision (reproducibility) of some 0.03" C., dependent upon the experience and skill of the observer. Accuracy was not established, results differing from psychrometer readings b y the equivalent of some 0.1 " C. variation in dew point. It is to be noted especially that this method must be classified among those depending upon the presence at the dew point of sufficient dew to be detected with certainty b y visual means. This would cause error in determinations on confined systems, through coincident decrease of vapor concentration in the sample whose composition is sought. Dew indication through alteration in surface resistance was investigated by Johnstone (4) and Tchang ( I S ) . The ease of visual observation of dew deposit was improved by the use of a platinum-blacked surface b y Stevenson and Babor ( l a ) , who applied their method to the study of the volatility of gasoline. Sage and Lacey (8, 9) applied a modification of the dew-point method to the investigation of phase equilibria in hydrocarbon mixtures. In t.hiscase dew was detected through thermal effects caused by the formation of a single hanging droplet 0.1 111111. in diameter. It is again noted that formation

INDUSTRIAL AND ENGINEERING CHEMISTRY

236

VOL. 10, NO. 5

DEW-MIRROR TEMPERATURE. The temperature of the dew mirror is controlled by circulation of water from thermostat B through pump Q and insulated lines 7'. Temperature of thermostat B is measured by a thermometer similar to that used in the large bath. For easier and more reliable readings of temperature intervals, a Beckman graduated to 0.01" C. is also employed. Rapid chilling of mirror for initial dew deposition is effected by use of cock E and water-cooled coils F. Figure 2 shows the submerged dew chamber, in n-hich is the mirror, M, of diameter 1.27 em. (0.5 inch). The flow of the sample is directcd horizontally across and immediately adjacent to this mirror. The mirror is integral vith the brass billet, C, which is thermally insulated by means of Bakelite disks B and plastic insulation I . Two holes were drilled through the billet at X,and countersunk. The enameled thermocouple wires, W , were brought up through these holes and fastened by filling FIGURE 1. APPARATUSFOR INVESTIGATION OF DEW DEPOSITION the countersinks with solder. Surface .M was then polished and chromium-plated in order to assist the deposition of dew in the form of many discrete droplets. of such an amount of liquid occasions change in the composiThe actual thermocouple junction is 0.8 mm. (0.03 inch) below tion of the gaseous phase. Tomlinson (14) made use of a mirror M . The temperature difference between these two points photoeIectric method for detection only, an arbitrarily seis calculated to be less than 0.01" C. when the mirror is 50" C. below the temperature of the gas body. lected quantity of dew deposit causing actuation, through The copper-constantan thermocouple wire, specially drawn, amplifier and relay, of a signal lamp. was tested for inhomogeneity, insulated with fine rubber tube, None of these methods succeeded in producing a satisfacand enclosed in a flexible waterproof metal conduit, which formed tory reduction of the first component of the temperature part of the interconnected equipotential shield protecting the entire measuring circuit from leakage currents. The cold junction gradient error previously mentioned. This might be accomis in thermostat B. The couple thus serves to measure merely plished by a method in which the amount of dew approached the temperature drop along the water-circulating system, and is zero at the dew point. Such a method could be applied to directly connected through an all-copper circuit with a sensitive confined systems without introducing further error through depletion of vapor in the gaseous phase. Requirements include extreme sensitivity coupled with a technic of continuous quantitative estimation of variation in dew quantity in the temperature range near the dew point. The apparatus described below was designed to meet these requirements.

pJcl

Method Accurate direct det,ermination of the dew point of confined samples is accomplished through a sensitive photoelectric means of dew observation, combined with a technic of intermittent temperature rise calculated to minimize the quantity of dew present at the time the deposition surface reaches the dew-point temperature.

Apparatus Figure 1 is a diagrammatic representation of the apparatus, whose design included provision for operation above atmospheric pressure. In thermostat A is the dew chamber, D, through which a periodically reversed circulation of the gas body is maintained by the 10.2-em. (4-inch) stroke of a brass piston 12.7 cm. (5 inches) in diameter moving in a steel cylinder, C. The connecting coils, L, each composed of 0.9 meter (3 feet) of tubing 1.3 cm. (0.5 inch) in diameter, provide added surface for the maintenance of constant and uniform temperavure of the gas. The Bourdon pressure gage, G, is connected with chamber D through an oil- and mercuryfilled loop to minimize dead-end space. Bath temperature is measured by a calibrated thermometer graduated in 0.1' c. For introduction of a sample, gas is passed through Milligan saturators S,cotton-packed spray catcher R, heated vapor line H , valve J, chamber D, coils L, and cylinder C to outlet valve K , the iston being in operation during the process. ~ A G N E T I C A L L YOPERATED PISTON.The circulating piston is raised by the fan-cooled solenoid, M , contained in the thermally insulated brass can, U. The brass cylinder extension, -V, is bathed in water circulated from thermostat A by gear pump P through an insulated pipe. The rate of rise of the piston is controlled by an attached auxiliary piston working in mercury well W , displacement of mercury occurring through channels controlled by needle valves situated within the apparatus. Rise of piston was set to about 1 minute, fall requiring 2 minutes. A motor-driven mercury switch controls the solenoid operating cycle, which totals 3.6 minutes.

FIGURE2. DEW CHAMBER galvanometer. Before the billet, C, was bolted into place, the thermocouple and galvanometer set-up was calibrated directly against carefully compared Beckman thermometers, yielding a mean value 0.023' C. per mm. of scale deflection. From the temperature of bath B, the mirror temperature can thus be calculated. OPTICALSYSTEM.The source of light is a concentrated filament storage battery lamp. The parallel beam produced by a

ANALYTICAL EDITION

MAY 15, 1938 collimating system passes through an infrared filter and is reflected down along one side of pipe P through window G to a small total reflecting prism. From this prism the beam reaches the mirror at an angle of some 10" to its surface, and thence, by means of a second reflecting prism, is made to travel back up the other side of pipe P to be reflected to a sensitive photoelectric cell. Owing to the small angle between the incident beam and the mirror surface, the large number of discrete dew droplete intercept and disperse a large fraction of the light, increasing the sensitivity of dew detection. AMPLIFIER.The photoelectric cell controls the grid circuit of a three-element vacuum-tube amplifier. To attain satisfactory constancy of operating conditions, heavy-duty B-batteries are used in conjunction with a storage Abattery. Plate current is read to 0.02 ma. Drift is determined before and after each run.

Results A series of preliminary investigations indicated that a gradual decrease in light

237

II

w

k 0.

transmission occurs with decrease in mirror temperature, even when the latter remains well above the dew point. KO such effect was noted when the apparatus was evacuated, nor when i t was filled with dried air. It appears that the apparatus is sufficiently sensitive to register the presence of gaseous films adjacent to the mirror, of composi29.0 29.1 29.2 29.3 29.4 29.5 29.6 tion differing somewhat from the body of gas due to localized cooling a t nearly conTEMPERATURE IN DEGREE3 CENT. stant pressure. FIGURE 3. COMPARISON OF TECHNICS OF D~TERMINATION CONTINUOUSTEMPERATURE CHANGE. For slow cooling, the plot of plate current versus mirror temperature showed no sharp break, but current change) each series of observations a t a given temchanged direction gradually over a range of several tenths of perature. Plots 2 and 3, Figure 3, drawn from the extrapoa degree. Determination on falling temperature was dislated values, also agree within 0.02" C. Moreover, no carded in favor of a slow temperature rise following prereadable difference in dew point resulted, in either case, from liminary deposition of dew. use of extrapolated instead of final readings. It appears that Plot 1, Figure 3, illustrates the form of graph obtained the work of extrapolation may be omitted. through runs by the latter method. There are two breaks, COMPARISON OF TECHNICS. Determinations represented in the less distinct lower break, L,and the sharp upper break Figure 3 were all on the same sample, of about 90 per cent which no doubt vould be the only one observable by direct relative humidity. It now seems clear that the break, L,of visual means. However, in runs on the same sample at a plot 1is to be identified with the true dew point, as determined heating rate of about 0.004' C. per minute, the lower breaks by plots 2 and 3. checked one another within 0.01 " C., while the upper breaks The intermittent rise method presents advantages of imdiffered by over 0.1" C. Varying the heating rate from proved sensitivity and superior convenience. Its success de0.004' C. per minute in one run to 0.014' C. per minute in anpends upon the use of sensitive instrumental observation, other, the discrepancy between upper breaks increased to such as the photoelectric system herein described. 0.2' C., while the lower breaks again checked each other. I t SATURATED SAMPLES. The means leading to precision of appears that the lower break, not the upper one, corresponds dew-point determination having been investigated, it was deto the true dew point. Unfortunately, the lower break is sired to discover if the accuracy attainable was of comparable poorly defined. degree. It was found impossible to introduce into the apINTERMITTEST TEMPERATURE CHANGE. T o eliminate the paratus a prepared partially saturated sample without change lag of dew evaporation with rising temperature, further runs in composition far greater than the precision of the determinawere conducted in a stepwise manner. After preliminary tion. It was accordingly decided to work with saturated deposition of dew, the rise was accomplished by rapid heating samples, prepared by introduction of water directly into the through suitable small temperature intervals, in each case tubes connecting cylinder with dew chamber. maintaining temperature a t the new level until plate current The continuous rise method produced in this case no defibecame constant, the criterion of the latter being in most nite break in the plotted results, but the intermittent rise casea a maximum change of about 0.04 milliampere per cycle technic yielded the plots of Figure 4. Letters D indicate the (3.6 minutes). The final reading of plate current, in each dew points of the respective samples, caIculated to the temseries, w&s plotted against temperature. perature scale plotted by consideration of thermometer correcFour such determinations checked within an extreme tions and reading of the differential galvanometer. Letters B range of 0.02' C., the plots consisting of two well-defined indicate the observed breaks. B and D differ in each case by intersecting straight lines. I n two of these runs the point some 0.04' C. There is uncertainty as to the exact point of nearest the intersection fell off the lines. This defect was intersection, occasioned by the relatively great angle between remedied by extrapolating to infinite time (aero rate of plate the component sections of each plot. It is thus to be expected

INDUSTRIAL AND ENGINEERIKG CHEMISTRT

238

that a corresponding divergence from absolute values would be noted. While sensitivity, precision, and accuracy do not here measure u p to the precision noted on unsaturated samples, these runs do serve definitely to indicate that the break in question corresponds to the true dew point.

23.T

2Sb 231 258 TEMPERATURE m MC.CENT.

FIGURE4.

23.9

DETERMINATIONS ON SATURATED AIR

VARIATIONS IN TECHNIC. The objection might be advanced that absorption of infrared rays by the dew could have affected the observations. The infrared filter first used was simply a water cell. Replacement of the water by a 2 per cent solution of cupric chloride produced no apparent change in the final results. I n some runs, the light beam was blocked completely, except during periods of observation, without noticeable change in indications. KO improvement resulted from coating the mirror with platinum black (12), suspending gas circulation, or varying the rate of transition between test temperatures. Discussion The data give rise to a number of questions concerning the mechanism through which occurs the interchange between liquid and gaseous phases. Chief among these are:

VOL. 10,NO. 5

is advanced. This concept is in accord with accepted physical laws governing behavior of gases and vapors. Figure 5 presents temperature and vapor concentration gradients in the thin films immediately adjacent to the surface of the deposited liquid. The precise form of the plots, between the lettered points, is not material t o the development of the concept. Consider a general case, wherein a liquid surface is at a temperature T' below the dew point of a body of vapor-gas of temperature Tg and vapor concentration A , less than saturation. The temperature gradient causes a corresponding density gradient, producing a stratification in the gas phase immediately adjacent to the liquid. This will be most marked when the liquid surface is horizontal and there is but little circulation in the gas phase, but will probably exist t o lesser degree in absence of either of these condit,ions. In the diagram, the range above Tg and A is that wherein circulation maintains approximate uniformity in composition and temperature of the gas phase. rlpproaching the liquid-gas interface, the temperature declines. The first effect of this, indicated b s section A B of the concentration line, is to increase vapor concentraZ4e0 tion, since this localized cooling is at essentially constant pressure. The film so produced is still unsaturated, until with decreasing temperature and increasing vapor concentration, saturation is reached at concentration B and temperature T. This temperature T is the true dew point. The liquid surface is at a still lower temperature, T', and the gas in direct contact with it has a vapor concentration C, which is loxer than B , owing to condensation of liquid from the gas phase. Thus there must exist between points B and C a saturated film, across which there is a concentration gradient as well as a temperature gradient. Keevil and Lewis (5) discussed a comparable condition in connection with the dehumidification of air, but omitted consideration of the unsaturated film AB. In the present instance, a steady state exists at each test temperature, without transfer of vapor across the double film. If the system reached this state by prior lowering of the liquid surface from a higher temperature, the saturated film may contain, suspended in it, a fog of liquid droplets, whose source was the condensation above mentioned. Were the original vapor-gas mixture saturated, there would be no unsaturated film. The temperature gradient, TgT,and the concentration gradient', A B , would become zero. The character of the saturated film would remain as indicated in the diagram.

1. Equilibrium when mirror is below the dew point. During

CORRELATIOK KITH THE DATA. From the standpoint of the concept above developed, the major questions raised by

I n correlating these ideas, it should be borne in mind that the m o u n t of light transmitted to the photocell is affected by changes in the gaseous phase as well as in the liquid phase. Such changes may include convection currents or the formation of films of varying thickness and vapor content. They may partially deflect the light beam from its normal course through mirror and aperture system, or alter its intensity by absorption. It is also to be remembered that the temperature gradient, between the dew mirror and the body of the gaseous phase, will be largely across the gas film rather than the liquid. To coordinate the observed DOUBLE-FILM HYPOTEESIS. qualitative and quantitative data the doublefilm hypothesis

1. Equilibrium when mirror is below the dew point. The above concept makes it clear that the liquid surface is in equilibrium with a gas carrying vapor concentration C, Figure 5. This concentration may be less than that in the body of the gas, owing to prior condensation within the saturated film. Hence for each mirror temperature, an equilibrium condition may be established, even though the mirror is below the dew point. 2. Breakinplot for unsaturatedsamples, intermittent rise runs. Referring again to Figure 5, if the temperature of the liquid surface be raised through a small interval, and held at the new level, a readjustment of both films may be expected to occur. Changes will involve temperature gradients, concentration gradients, and thicknesses, the general relationships remaining as before, so long as T' is still below the true dew point T . Changes in light reflection between temperature levels are repreEented by the left seetion of, for example, plot 2, Figure 3. These changes are affected also by alterations in amount of dew on the mirror. When T' is raised to coincide with T, there is no longer a saturated film, nor will the liquid phase persist above this temperature. Further temperature increase causes variations in the remaining single unsaturated film, represented by the right section of plot 2, Figure 3. The abrupt change of slope is a consequence of the abrupt change in physical nature of the entities affecting the transmission of the light. Another break might be expected if T' were raised high enough to coincide with Tg,the temperature of the gaseous body, at which point the unsaturated film would in turn disappear. 3. Break in plot for saturated samples, intermittent rise runs. In this case there is at no point an unsaturated film. The cause of the breaks in the plots, Figure 4, is entirely different from that discussed in the preceding paragraph in connection with un-

intermittent rise runs it w a observed, ~ at each temperature level, that the light transmission became greater than that a t the preceding level, but slowly approached constancy. From usual considerations, it would be expected that dew would deposit on, rather than evaporate from, a surface remaining at a temperature below the dew point. 2. Break in plot for unsaturated samples, intermittent rise runs. An explanation is needed for the abrupt change in slope. Note that since these were equilibrium readings, no rates of evaporation or diffusion are involved. 3. Break in plot for saturated samples, intermittent rise runs. Why is the change in slope less than in the case of unsaturated samples? 4. Breaks in plots for unsaturated samples, continuous rise runs. Why is the lower break lacking in sharpness? What is the significance of the upper break, and why does its position vary widely in runs under different conditions of dew and heating rate?

the experimental data can now be answered.

MAY 15, 1938

ANALYTICAL EDITION

saturated samples. In saturated samples, the transition is from a condition wherein there is present a saturated fdm of varying thickness, to one wherein there is no film of this character. When T' becomes greater than Tg slight convection currents may be set up, whose disturbance of light transmission is, in part, the cause of the negative slopes of the right sections of the plots in Figure 4. Definite indication of the existence and effect of such convection currents has been noted. With rapid continuous heating of the mirror, in the absence of dew, sudden drops in light transmission occurred when mirror temperature exceeded the temperature of the gas body by some 0.1" C. 4. Breaks in plots for unsaturated samples, continuous rise runs. The lack of sharpness in the lower break of, for example, plot I, Figure 4, may be attributed to disturbances arising from irregular convection currents. Such currents are caused by the relatively rapid and continuous rise of the temperature of the dew surface. Temperature gradients set during such a rise are the reverse of those existing in the double film a t equilibrium, and, time being insufficient to allow their dissipation through conduction or readjustment of the film, a convection overturn occurs. The upper break is thought to arise from a still different source from those previously discussed, in this case corresponding to the completion of the processes which, were it not for the hysteresis introduced by the continual variation in temperature, would have been completed at the lower break. The wide divergence in upper breaks in different runs reflects different values of this hysteresis, brought about by variation in amounts of dew originally deposited, and by variation in the heating rates.

DETERMINATION AT OTHERHUMIDITIES. I n determinations of dew point b y usual means, error increases with lowered humidity. This is due primarily to the augmented temperature gradient between the body of vapor-gas and the temperature-measuring device. As set forth in the discussion of design of apparatus, this causes error in two ways.

-- -

MPOR WCENTWITWN

TEMPERATURE

'

I

I

I

I

I \ \

I T'/

BODY OF VAPOR-GM

I UNSCITUWTED FILM

3ATURCITED FILM

c/ VAPOR CONcENTRflTION ENPER6lTURE

-

1

e

FIGURE5. MECHANISM OF PHASECHANGE I n the present apparatus, error due to temperature gradient between thermocouple and mirror surface has been reduced to a n estimated 0.01" C. for a 50" differential between temperatures of sample and dew-point mirror. Error due t o temperature gradient across the dew film is eliminated b y two means. First, a n exceedingly sensitive instrumental method of detection is employed, which reveals the presence of very small amounts of dew, thus permitting temperature observation a t a time when error is very small. Second, and

239

of greatest importance, each dew-point determination is derived graphically from a continuous series of observations which plot as two intersecting straight lines. Observations fixing one of these lines are made in absence of the liquid. In observations fixing the other straight line, quantity of dew (and hence temperature gradient' error) decreases to zero a t the intersection. Thus there appears no reason to suspect that precision or accuracy of this apparatus should fall off materially upon application to samples of lower vapor content. As a matter of fact, precision a t 90 per cent humidity was markedly superior to that at 100 per cent humidity.

Application

It is indicated that fundamental obstacles to dew-point d e termination of high precision and accuracy, exclusive of instrumental and observat'ional errors, are: 1. The inherent sloivness of diffusional processes. This leads to hysteresis in determinations involving continuous temperature change. Methods involving control of amount of dew deposited and of heating rate might succeed in standardizing this hysteresis. Result,s would then show precision (sensitivity and reproducibility) but not absolute accuracy. Reduct ion of hysteresis, through slow heating, increases the time of a determination beyond that desirable. 2. With the elimination of hysteresis by adoption of the intermittent rise technic, there is indication of the presence of a double gaseous film adjacent to the liquid, of which the upper or unsaturated film is still present at temperatures above the dew point. This film appears to produce an effect, at, least with regard to light transmission, similar in nature to a persistence of the dew itself. This effect affords explanation of the difficulty of obtaining concordant indications of dew point where reliance is placed upon visual observation.

The apparent way to obtain still sharper indications of dew point, and simultaneously to realize a short,er period of determination, is to cause the sample to move a t high velocity across the surface on which dew is deposited. The object is to minimize film thicknesses, and also to increase diffusion rates. Correction for pressure changes would be necessary. Such a n application, in combination with photoelectric or other instrumental means of dew observation, would appear to be a useful research tool, as, for example, in the determination of pressure-phase relationships in complex hydrocarbon mixtures a t constant temperature. Sensitive control of vapor mixtures in industrial processes presents another possibility. The accuracy of dew-point determination which has been developed opens the way to possible new applications. For example, the measurement of very low concentrations of a vapor in a gas is rendered practicable by the combination of such accurate determination mith the following suggested principle of operation: A reference mixture is first prepared, consisting of gas partially saturated with a selected vapor, and the dew point (with respect to that vapor) is determined. The sample, of unknown vapor concentration, is now pumped into the space occupied by the reference mixture, and the new dew point is determined. The difference in dew points is a sensitive measure of the added rapor concentration carried in by the unknovn sample. Multiplied sensitivity could be attained by continuing to pump in the unknown sample until a total pressure of sereral atmospheres had been reached. I n the latter case the effects of dissolved gas, and of increased pressure, upon the vapor pressure of the liquid phase should be considered.

Summary and Conclusions An apparatus has been designed which minimizes the known instrumental and observational errors in the determination of dew point.

INDUSTRIAL AND ENGINEERING CHEMISTRY

240

The technic of applying this apparatus to the elucidation of the inherent difficulties of dew point determination has been developed. R i d e discrepancies are introduced by hysteresis in denevaporation. These have been investigated and their extent has been indicated. A technic for eliminating hysteresis, at the expense of time consumption, has been evolved. It has been shown possihle to obtain a precision of about +0.01" C. a t 90 per cent humidity, and *0.05" C. a t 100 per cent humidity. Observations on the saturated samples checked absolute values within the stated limits of precision (reproducibility). A hypothesis has been advanced with regard to the structure of gaseous films adjacent to the liquid phase. From this hypothesis has been formulated a concept of the mechanism of dew formation and evaporation, which affords explanation of the difficulty in obtaining concordant dew point indications by visual means. A means of increasing further the sharpness of dew indication, simultaneously decreasing the time required for a determination, has been outlined. Application of accurate dew-point determination as a research tool has beeE considered.

VOL. 10, NO. 5

Acknowledgment is made to Daniel C. Lindsay, formerly of the Carrier Engineering Corporation, for suggestions concerning apparatus, to the General Electric Company for gifts of equipment, and to James Reid for his precision machine work.

Literature Cited Griffiths, E., Proc. P h y s . SOC.London, 34, 8 4 9 , esp. 25 (1922). Gruse. \Jr. 8 . ,I N D . EKG.&EM., 15, 796 (1923). Holtzmann, E., P h y s i k . Z., 25, 443 (1924). Johnstone, H. F., Univ. Illinois, Circ. 20 (1929). Keevil, C. S.,and Lewis, W. K., IXD.ENG.CHEM., 20, 1058 (1928).

Kennedy, R . J., Bur. Standards, Sci. Paper 500 (1924). Regnaulc, V., -4nn. chirn. phys., [3] 15, 129 (1845). Sage, B. H., and Lacey, W. N., IXD. ENG.CHEM., 26, 103 (1934). Sage, B. H., Schaafsma, J. G . , and Lacey, W. N., Ibid., 26, 1218 (1934).

Shaw, A. N., Trans. Roy. SOC.Canada, [3] 10, Section 111, 85 (1916).

Shaw, W. N., Trans. Roy. SOC.London, Series A, 179, 73-149, esp. 74, 112 (1888). Stevenson, R., and Babor, J. A., IND.ENQ.CHmf., 19, 1361 (1927).

Tchang Te-Lou, Rev. univ. mines, [8] 5, 161 (1931). Tomlinson, M. C. W., U. S. Patent 1,883,116 (Oct. 18, 1932) RECEIVED February 7, 1938. Presented before the Division of Industrial and Engineering Chemistry, Symposium on Drying and Air Conditioning, American Chemical Society. Philadelphia, Pa., December 27 and 28, 1937.

Determination of Sugar in Curing Pickles and Dry-Curing Mixtures A Polarimetric Method A. D. RICH AND J. J. VOLLERTSEN, Armour and Company, Chicago, Ill.

0

NE important phase of packing-house laboratory control

over plant operations is the analysis of curing pickles both new and used, and dry-curing mixtures. The former are solutions of sodium chloride containing sucrose in the form of raw or granulated sugar and the regular curing ingredients, sodium nitrite and sodium nitrate, either singly or together. The concentration of sodium chloride varies from about 15 per cent t o saturation, while the sugar range is from zero to about 5 per cent. Sodium nitrite and nitrate are present in considerably less amount, seldom exceeding 0.5 per cent for the nitrate and 0.2 per cent for the nitrite. Drycuring mixtures differ from pickles in that they contain these ingredients in the dry state. The sugar determination (by any of the recognized gravimetric or volumetric methods) consumes the most time and is the least accurate of the ingredient tests, and a quick and reasonably accurate method would greatly facilitate pickle and dry-cure control and save much time and labor in the laboratory.

Cse of Polariscope The polariscope in the field of sugar chemistry is employed ordinarily on solutions containing sugars with no inorganic substances present. On account of its dependability and production of uniform results, particularly on sucrose, the instrument was considered suitable for this study, despite the corrections that necessarily would have to be applied with its use.

CORRECTION FOR SODIUM CHLORIDECONCENTRATION. The literature contains numerous articles which demonstrate the depression of optical rotation of both sucrose and invert sugar towards the negative side in the presence of this salt. Unfortunately the data presented are scattered and entirely insufficient to develop the necessary curves for the methods desired. Moreover, few or no data are presented which show the effect of the higher concentrations of sodium chloride that are found in curing pickles. It was necessary, therefore, t o develop the correction by several experiments. CORRECTION FOR INORGANIC IMPURITIES I N SODIUllr CHLORIDE. Ordinary curing salt contains these impurities (cal-

cium sulfate, calcium chloride, magnesium chloride, etc.) in very small quantities, and the literature indicates that there is no great difference between their influence and the influence of sodium chloride upon the optical activity of sucrose. It was decided, because of this obviously negligible effect, not t o consider them.

CORRECTION FOR SODIUM NITRITEAND SODIUMNITRATE. As only scattered data are available, i t became necessary t o develop this by experimentation. CORRECTION FOR PRESENCE OF INVERT S U G a R I N SUCROSE.

This factor possesses some significance. It would be possible to invert the solution containing the sucrose and calculate total sugar as invert, but this would add another step of considerable length. A study of numerous analyses of raw and granulated sugar disclosed that the invert content was fairly constant in both types. For all practical purposes a n assumption could be made that there is 1.5 per cent of invert