Analysis of Heterocyclic Amines in Meat by the Quick, Easy, Cheap

Oct 3, 2017 - Analysis of Heterocyclic Amines in Meat by the Quick, Easy, Cheap, Effective, Rugged, and Safe Method Coupled with LC-DAD-MS-MS...
0 downloads 0 Views 1MB Size
Subscriber access provided by UNIV OF ESSEX

Article

A quick method for analysis of heterocyclic amines in meat by QuEChERS coupled with LC-DAD-MS-MS Han-Yin Hsiao, Bing Huei Chen, and Tsai Hua Kao J. Agric. Food Chem., Just Accepted Manuscript • DOI: 10.1021/acs.jafc.7b03739 • Publication Date (Web): 03 Oct 2017 Downloaded from http://pubs.acs.org on October 4, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Journal of Agricultural and Food Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 33

Journal of Agricultural and Food Chemistry

A quick method for analysis of heterocyclic amines in meat by QuEChERS coupled with LC-DAD-MS-MS

Han-Yin Hsiao, Bing-Huei Chen and Tsai-Hua Kao* Department of Food Science, Fu Jen University, Taipei, Taiwan 242 * To whom correspondence should be addressed E-mail: [email protected]; PH: 886-2-29053629; Fax:886-2-29051215

1

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

1

Page 2 of 33

ABSTRACT

2

The traditional way to analyze heterocyclic amines (HAs) is time-consuming and uses large

3

amounts of solvents. The objective of this study is to develop a quick and simultaneous analysis

4

method for multiple types of HAs contained in meat products. Results showed that 20 HAs and 1

5

internal standard (4,7,8-TriMeIQx) can be separated within 30 min using an Inspire C18 column and a

6

gradient solvent system containing a 10-mM ammonium acetate (pH 2.9) and acetonitrile. This process

7

resulted in a high degree of separation. Using acetonitrile with 1% acetic acid as extraction solvent,

8

followed PSA, MgSO4, and C18EC as purified reagent, is highly suitable for extracting HAs using

9

QuEChERS. Tandem mass spectrometry with selected reaction monitoring mode were used for

10

analysis, which indicated reasonable recovery (58.9-117.4%) for all 20 types of HAs along with limits

11

of detection and quantification in the range of 0.003–0.05 ng/g and 0.01–0.05 ng/g, respectively.

12

13

Keyword: heterocyclic amines, QuEChERS, LC-DAD-MS-MS, meat

2

ACS Paragon Plus Environment

Page 3 of 33

14

Journal of Agricultural and Food Chemistry

INTRODUCTION

15

Heterocyclic amines (HAs) are formed by C, H, and N atoms and are cluster compounds with a

16

heterocyclic structure. They are commonly found in heat-treated high-protein food products such as

17

seafood and meat products. Related literature shows that HAs have mutagenic and carcinogenic

18

properties.1 The International Agency for Research on Cancer has listed 12 types of HAs as possible

19

human carcinogens (class 2B) and IQ as a probable human carcinogen (class 2A).2

20

Since the concentration of HAs in food products is low and the food matrix is complicated, most

21

studies have used solvent extraction and solid phase extraction for analysis, wherein, generally,

22

diatomaceous earth is used to absorb large particles and then solvents are employed to extract the

23

HAs.3-5 The most commonly used solvents are ethyl acetate and dichromathane. A propylsulphonic

24

acid silica gel cartridge is then used for weak cation exchange, or a mixed-mode cation exchange

25

adsorbent (Oasis MCX type, from Waters Co.) is used for purification, where MeOH/0.1 M HCl

26

(40/60, v/v)-based propylsulphonic acid silica gel is used to elute relatively nonpolar HAs. Then, a

27

0.5-M ammonium acetate solution (pH 8.0) is used to elute relatively polar HAs. The two solvents are

28

then eluted separately using methanol and ammonia (9:1 v/v) in C18 solid phase extraction tubes,3

29

whereas MeOH/25% ammonia (19:1 v/v) is used to elute HAs using the Oasis MCX cartridge.4,5 3

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

Page 4 of 33

30

However, the aforementioned traditional method of extraction is extremely time-consuming and

31

generally provides a low recovery. Hence, there is a need to develop a faster and more convenient

32

method of analysis.

33

HAs are generally analyzed using gas chromatography-mass spectrometry (GC-MS) and

34

liquid-chromatography-mass spectrometry (LC-MS). GC-MS has high sensitivity, but it induces mild

35

pyrolysis in the benzene ring of HAs therefore the derivatization process is necessary for GC analysis.

36

However, the derivatization treatment is time-consuming and not all HAs can be derivatized

37

appropriately.6 LC has a relatively high sensitivity and can be used with photodiode array,7

38

fluorescence,8 and MS9 detectors for the analysis of HAs. Apart from the difference between LC and

39

GC systems, the types of columns and mobile phases also affect HAs significantly. The columns used

40

for HAs analysis include TSKgel ODS-80, Shim-pack XR-ODS, Acclaim™ 120 C18, and BDS

41

Hypersil C18,3,4,10-12 of which TSKgel ODS-80 can separate the most number of HAs (total of 15

42

types). This study aimed to develop an effective LC-MS-MS method for separation of HAs

43

simultaneously as well as apply the QuEChERS for quick HAs extraction.

44

MATERIALS AND METHODS

45

Materials 4

ACS Paragon Plus Environment

Page 5 of 33

Journal of Agricultural and Food Chemistry

46

Roasted duck was purchased from local market. Pork fiber was self-fried, where 6 kg of pork

47

hind leg was cooked in 5 kg of water for 1 h until the meat was soft. After being cooled, the pork was

48

beaten into fibrous meat and added with flavoring (30% broth, 20% sugar, 14% lard, 8% soy sauce,

49

1.6% salt, 1% MSG). A pork fiber machine was then used to fry the meat fiber (150°C, 40 min). After

50

being cooled, the pork fiber was vacuum-packaged and stored at -20°C.

51

Chemicals and Reagents

52

Twenty HAs standards including 2-amino-1,6-dimethylimidazo[4,5-b]-Pyridine (DMIP),

53

2-aminodipyrido-[1,2-a:3',2'-d]imidazole

54

(iso-IQ),

55

2-amino-3-methyl-imidazo[4,5-f]-quinoline (IQ), 2-amino-6-methyldipyrido-[1,2-a:3',2'-d]imidazole

56

(Glu-P-1),

57

2-amino-3,8-dimethyl-imidazo[4,5-f]-quinoxaline

(8-MeIQx),

58

2-amino-1-methyl-imidazo[4,5-b]-quinoline

(IQ[4,5-b]),

59

2-amino-1,6-dimethyl-furo[3,2-e]imidazo[4,5-b]-pyridine

60

2-amino-3,7,8-trimethyl-imidazo[4,5-f]-quinoxaline

61

2-amino-3,4,8-trimethyl-imidazo[4,5-f]-quinoxaline

(Glu-P-2),

2-amino-1-methyl-imidazo[4,5-f]-quinoline

2-amino-3-methyl-imidazo[4,5-f]-quinoxaline

2-amino-3,4-dimethyl-imidazo[4,5-f]-quinoline

(IQx),

(MeIQ),

(IFP),

(7,8-DiMeIQx),

(4,8-DiMeIQx),

5

ACS Paragon Plus Environment

9H-pyrido[3,4-b]indole

Journal of Agricultural and Food Chemistry

Page 6 of 33

62

(Norharman), 1-methyl-9H-pyrido[3,4-b]indole (Harman), 2-amino-5-phenylpyridine (Phe-P-1),

63

3-amino-1-methyl-5H-pyrido[4,3-b]indole

64

2-amino-1-methyl-6-pheny-limidazo[4,5-b]-pyridine

65

3-amino-1,4-dimethyl-5H-pyrido[4,3-b]indole (Trp-P-1), 2-amino-9H-pyrido[2,3-b]indole (AαC),

66

2-amino-3-methyl-9H-pyrido[2,3-b]indole

67

2-amino-3,4,7,8-tetramethyl-imidazo[4,5-f]-quinoxaline

68

Research Chemicals Co. (Downsview, Ontario, Canada). Deionized water was produced using the

69

Milli-Q water purification system manufactured by Millipore (Bedford, MA, USA). Acetic acid and

70

ammonium acetate was purchased from Sigma-Aldrich (St, Louis, MO, USA). The QuEChERS

71

extraction set, purchased from Uni-Onward Corp. (Taipei, Taiwan), included extraction powder

72

(product number UR-EX), purification powder (product number UR-CLEAN-II), ceramic

73

homogenizers, and centrifuge tubes. The extraction powder contained 4 g of anhydrous magnesium

74

sulfate (MgSO4) and 1 g of anhydrous sodium acetate (NaOAc). The purification powder contained

75

300 mg of PSA (primary and secondary amine), 900 mg of MgSO4, and 300 mg of C18EC.

76

Instrumentation

77

(Trp-P-2),

(MeAαC),

(PhIP),

as

well

as

(4,7,8-TriMeIQx)

1

internal

were

from

standard

Toronto

Inspire C18 and TSKgel ODS-80 (250 mm × 4.6 mm I.D., 5 µm) columns were from Dikma 6

ACS Paragon Plus Environment

Page 7 of 33

Journal of Agricultural and Food Chemistry

78

Technologies (Lake Forest, CA, USA) and TOSOH (Tokyo, Japan), respectively. Gourd columns

79

EasyGuardTM and security guard C18 were from Dikma Technologies and Phenomenex (Torrance,

80

CA, USA). HPLC-DAD system with PU2089 Plus pump and MD-2010 diode array detector were

81

from Jasco (Tokyo, Japan). Dionex UltiMate 3000 Open Sample XRS System UPLC, and TSQ

82

Quantiva triple quadrupole tandem mass spectrometer were from Thermo Fisher Scientific (San Jose,

83

CA, USA).

84

Evaluation of Simultaneous Separation Conditions by LC

85

The optimal separation condition was evaluated by using different columns (Inspire C18 and

86

TSKgel ODS-80), flow rates (0.6–1 mL/min), and a mobile phase comprising 10 and 50 mM

87

ammonium acetate buffer solutions with pH 2.8–3.6.

88

Development of the QuEChERS Method for HAs Extraction

89

Two gram of homogeneous roasted duck meat and 10 mL of deionized water were placed into a

90

50-mL centrifuge tube. After shaken for 10 min, 10 mL of different extraction solvents (methanol,

91

ethyl acetate, acetone, and acetonitrile, which contains 1% formic acid and 1% acetic acid acetonitrile)

92

was added. After the mixture was shaken for 10 min, a ceramic homogenizer and a packet of extraction

93

powder were added, which were vigorously shaken manually for 1 min before being centrifuged at 7

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

Page 8 of 33

94

3200 g and 4°C for 5 min. Then, 6 mL of supernatant was collected and transferred into a 15-mL

95

centrifuge tube along with the purification powder. After vigorous manual shaking for 1 min, the

96

mixture was centrifuged (3200 g, 4°C, 5 min), 1 mL of supernatant was collected and solvent was

97

removed by dryness with nitrogen. Finally, 200 µL methanol contained 1 ppb of internal standard was

98

used to dissolve the extract and then filtered using a 0.22-µm PVDF syringe filter prior to LC analyses.

99

Identification of HAs

100

The UV–Vis spectra, retention time, and MS-MS spectra of the samples were compared with

101

those of the standards. The MS-MS spectra were detected with electrospray ionization in positive

102

mode with the following condition: 3000 V spray voltage for ion source, sweep gas flow rate 2

103

arbitrary units, sheath gas flow rate 50 arbitrary units, auxiliary gas flow rate 20 arbitrary units, ion

104

transfer tube temperature 368°C, and vaporizer temperature 315°C.

105

Method Validation

106

Precision

107

HAs extract with 20 HA standards (0.2 ng/mL) and internal standard (1 ng/mL) was prepared

108

and injected five times on the same day, with the relative standard deviation (RSD%) being calculated

109

to obtain the intra-day variability. Similarly, the HAs extract containing standards and internal standard 8

ACS Paragon Plus Environment

Page 9 of 33

Journal of Agricultural and Food Chemistry

110

was injected three times on three non-continuous days, and the inter-day variability was measured

111

based on RSD%.

112

Limits of Detection and Quantification

113

The confirmation ion signal (Sc) and quantitation product ion signal (Sq) of 20 HAs were

114

detected by LC-MS-MS. The detection limit (LOD) was determined based on Sc/N ≥ 3 and Sq/N ≥ 3.

115

The limit of quantification (LOQ) of harman and norharman was obtained by multiplying the LOD

116

with 3.3. The LOQ for the other HAs was measured based on Sc/N ≥ 3 and Sq/N ≥ 10.

117

Recovery

118

Two levels of HAs standards including 10 ng/g and 1 ng/g of DMIP, Glu-P-2, iso-IQ, IQ, IQx,

119

MeIQ, Glu-P-1, 8-MeIQx, IQ[4,5-b], IFP, 7,8-DiMeIQx, 4,8-DiMeIQx, Phe-P-1, Trp-P-2, PhIP,

120

Trp-P-1, AαC, MeAαC; 20 ng/g and 40 ng/g of norharman, and 400 ng/g and 800 ng/g of Harman,

121

were mixed with 2 g of fried pork fiber. Following extraction by QuEChERS and HPLC analysis, the

122

recovery of each HAs was obtained based on the following formula:

123

Recovery (%) = [(spiked amount plus original amount) - (original amount)] / spiked amount

124

Matrix Effect

125

The 20 HAs standards were separately dissolved in methanol (sample solvent) and fried pork 9

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

Page 10 of 33

126

fiber extract (matrix) to prepare solutions with 0.05, 0.1, 0.5, 1, 2, 2.5, and 10 ng/mL concentrations.

127

These were then analyzed using LC-MS-MS to obtain standard calibration curves (SCC) and matrix

128

matched calibration curves (MCC). The matrix effect was obtained using the following formula:

matrix effect =

129

(slope of MCC − slope of SCC) × 100% slope of SCC

Quantification of HAs

130

HAs standards were mixed and prepared in fried pork fiber extract with concentration of 0.05,

131

0.1, 0.5, 1, 2 and 2.5 ng/mL. Then each standard solution was mixed with internal standard with a

132

fixed concentration at 1 ng /mL. After analyzing by LC-MS-MS based on selective reaction

133

monitoring (SRM), each standard curve was prepared by plotting concentration ratio (standard vs

134

internal standard) against its area ratio, and the regression equation and correlation coefficient (r2) were

135

automatically obtained. Each HA was quantified using the following formula:

136

Concentration of HAs (ng/g) =

137

{[(A/RRF)/Ai] x Ci x volume of extract x dilution factor /recovery} / weight of sample (g)

138

where A is the area of each HAs; RRF is relative response factor = (A/Ai) / (C/Ci); Ai is the area of

139

internal standard; Ci is the concentration of the internal standard.

140

Statistical Analysis 10

ACS Paragon Plus Environment

Page 11 of 33

141

Journal of Agricultural and Food Chemistry

Both LC analysis and QuEChERS were performed twice. The data were analyzed by ANOVA

142

and Duncan’s multiple rang test for significant difference (P