Subscriber access provided by CORNELL UNIVERSITY LIBRARY
Article
Analysis of measurement errors in passive sampling of porewater PCB concentrations under static and periodically vibrated conditions Mehregan Jalalizadeh, and Upal Ghosh Environ. Sci. Technol., Just Accepted Manuscript • Publication Date (Web): 24 May 2017 Downloaded from http://pubs.acs.org on May 27, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 24
1 2 3
Environmental Science & Technology
Analysis of measurement errors in passive sampling of porewater PCB concentrations under static and periodically vibrated conditions
4 5 6 7 8 9 10
Mehregan Jalalizadeh and Upal Ghosh*
11
Department of Chemical, Biochemical, and Environmental Engineering
12
University of Maryland Baltimore County
13
Baltimore, MD 21250
14 15 16 17 18 19 20 21 22 23 24 25
*
Corresponding author:
[email protected]; 410-455-8665; Fax: 410-455-6500
26 27
ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 24
28
ABSTRACT
29
Although the field of passive sampling to measure freely dissolved concentrations in sediment
30
porewater has been sufficiently advanced for organic compounds in the low- to mid-range of
31
hydrophobicity, in situ passive sampling of strongly hydrophobic polychlorinated biphenyls
32
(PCBs) is still challenged by slow approach to equilibrium. Periodic vibration of polyethylene
33
(PE) passive samplers during exposure has been previously shown to enhance the mass transfer
34
of polycyclic aromatic hydrocarbons (PAHs) from sediment into PE. Herein, we used a new
35
vibrating platform, developed based on our earlier platform design, to demonstrate the
36
effectiveness of periodic vibration for large molecular weight PCBs such as hexa-, hepta-, and
37
octachloro-PCBs. Uptake of PCBs in PE after 7, 14, 28, and 56 days under different vibration
38
modes was compared to that under static and mixed laboratory deployments. All PCBs reached
39
within 95 – 100% of equilibrium after 56 days of deployment in the system vibrated briefly
40
every 2 min, while none of the congeners achieved more than 50% of equilibrium in static
41
deployment for the same period. Periodic vibration also increased the dissipation rate of four
42
performance reference compounds (PRCs) from passive samplers. Higher fractional loss of
43
PRCs and closer approach to equilibrium in the vibrated deployment resulted in estimation of
44
corrected porewater concentrations that were statistically indistinguishable from the true
45
equilibrium values even after a short 7-day deployment. Porewater concentrations of the strongly
46
hydrophobic PCB congeners were overestimated by up to an order of magnitude in the static
47
passive sampler after the same deployment time.
48 49 50 51 52 53 54 55 2
ACS Paragon Plus Environment
Page 3 of 24
Environmental Science & Technology
56
INTRODUCTION
57
Reliable bioavailability measurements of hydrophobic organic compounds (HOCs) such as
58
polychlorinated biphenyls (PCBs), and polychorinated dibenzo-p-dioxins/dibenzofurans
59
(PCDD/Fs) are needed for improved sediment risk assessments, proper selection of remedy, and
60
post-remediation monitoring. Several studies have shown that freely dissolved concentrations
61
(Cfree) of organics in sediment porewater can be related to toxicity and bioaccumulation.1,2
62
Passive sampling for the measurement of Cfree of organic pollutants in sediment porewater has
63
emerged as a very promising approach, but in situ measurements are challenged by slow mass
64
transfer of strongly hydrophobic compounds. The slow mass transfer results in under-
65
equilibrated passive sampler measurements that need to be corrected for determining Cfree. For a
66
passive sampler deployed in stagnant sediment, mass transfer of the contaminants is controlled
67
by transport through the polymer and/or sediment phase, depending on the sediment sorption
68
characteristics and diffusivity of the pollutants in sediment porewater and polymer.3 For HOCs,
69
the overall kinetics is often controlled by transport through the sediment phase.3-5Under this
70
condition, correction for non-equilibrium requires estimation of site specific sorption
71
characteristics (e.g., retarded diffusion). The previously developed methods determined site-
72
specific sorption characteristics from the loss kinetics of selected performance reference
73
compounds (PRCs) and calculated corrected Cfree from non-equilibrium polymer
74
concentrations.3,6 However, even with these methods, estimating Cfree of strongly hydrophobic
75
compounds is prone to errors. Extrapolations based on the loss kinetics of strongly hydrophobic
76
PRCs is challenging, since long exposure times are required to measure PRC levels that are with
77
statistical significance different from the initially spiked PRC levels.6 For example, Choi et al.4
78
observed only 20% reduction in concentration of PCB 192 from 17 µm PE after 265 days of
79
deployment in sediment. Also, high imprecisions involved in the measurement of fractional loss
80
of PCB 192, caused a wide confidence interval for the estimated sediment sorption
81
characteristics for this congener. In addition to the mentioned challenges with using the PRC-
82
correction methods, it is not clear yet whether the retardation factor for HOCs that diffuse from
83
sediment into the passive sampler is identical to the retardation factor for the PRCs that diffuse
84
out of the passive sampler and into the sediment. Apell and Gschwend5 argued that PCBs exhibit
85
the same retardation factor through the sediment when diffusing into and out of PE passive
86
samplers. However, anisotropic exchange kinetics of PCBs and DDTs has been observed for PE 3
ACS Paragon Plus Environment
Environmental Science & Technology
Page 4 of 24
87
and PDMS passive samplers in more recent studies.4,7 The mechanisms involved in anisotropic
88
exchange kinetics are not well understood, but possibly depend on the sediment properties.4
89
Enhancing the overall kinetics by reducing the mass transfer resistance in sediment overcomes
90
the mentioned shortcomings of PRC-correction methods. This assumption is tested further in the
91
present study.
92
In our previous work,8 we addressed the challenge of mass transfer limitation by using a
93
vibrating platform for the deployment of passive sampling devices in sediments. We
94
demonstrated through laboratory measurements and numerical modeling that the platform can
95
greatly enhance the rate of mass transfer of 16 PAHs (3.4