Analytical chemistry and consumerism in the automobile industry

Sep 1, 1974 - Analytical chemistry and consumerism in the automobile industry. Lynn L. Lewis. Anal. Chem. , 1974, 46 (11), pp 866A–879a. DOI: 10.102...
0 downloads 0 Views 16MB Size
Lynn L. Lewis Research Laboratories General Motors Technical Center Warren, Mich. 48090

ANALYTICAL CHEMISTRY AND CONSUMERISM To the consumer, the automotive industry may appear to be like a duck on water-calm, unruffled, and moving forward serenely. But I assure you that there is furious paddling beneath the surface! Amidst all of this vigorous activity, analytical chemistry has vital contributions to make on efforts to conserve materials, solve environmental problems, and ensure product quality. All of these activities require the analysis of chemical systems. Thus, the analytical chemist-a consumer-has direct responsibility in these matters. Today, 9% of personal income in the United States is spent on the automobile (Figure 1).Over two-thirds of all passenger car trips are related to earning a living and family business, and less than one-third is for religious, social, recreational, and other activities ( I ) . On the other side of the coin, some 13 million jobs-one in every six-are created directly or indirectly by this consumerism. An estimated 50,000 firms supply materials, parts, components, and services to motor vehicle manufacturers. Materials Usage. The automobile 866A

industry is properly regarded as a nonchemical industry, but chemistry is here to stay in an industry so heavily dependent on the properties of materials. This is illustrated by the fact that other industries annually produce over $13 billion in automotive parts, with an equally impressive employment (Figure 2). As another measure of materials usage, the average car contains about 15,000 parts. Relationship with Suppliers. When we think of “consumerism” and this industry, we tend to think offhand of the products of personal interest that we see on the highway. This industry is also a consumer, however, with nearly 50% of all revenue going to suppliers of materials and services. Thus, the companies have specifications and test methods for materials purchased and used in their products; in scope, these test methods may range from “ABS Plastics” to “Zinc Plating”. In addition, as a consumer the industry has direct interest in a t least 39 of the 47 parts of the “1974 Annual Book of ASTM Standards” of the American Society for Testing and Materials.

ANALYTICAL CHEMISTRY, V O l 46, NO. 11, SEPTEMBER 1974

With regard to consumer interest in reliable, high-quality products, 35,000 people will spend some 70 million man-hours this year on quality and reliability control in one automotive company alone (2).As an example of the benefit of this effort, the probability of a new car starting on demand is about 0.9995. (This is higher than the reliability of some parts on Apollo missions.) These facts and figures are suitably impressive, but my point in presenting them is to illustrate the fact that analytical chemistry contributions to this industry must include those stemming from all other industries that provide raw materials and parts. Because of the breadth of this subject, most of my references will now be limited to these activities within the automotive industry. Past Efforts Analytical Instrumentation. Analytical instrumentation has a long history of development and application in the automotive industry. For example,’in the late 1920’s all three physicists in the General Motors Research

Report

IN THE AUTOMOBILE INDUSTRY Laboratories had their PhD degrees in atomic or molecular spectroscopy ( 3 ) . At that time techniques for purifying hydrocarbons were certainly inadequate, and identification was limited mostly to melting point, boiling point, and refractive index. Thus, one of their early projects was on the development of infrared spectroscopy for the analysis of hydrocarbon mixtures for fuel-engine studies on the knocking characteristics of various gasolines. They also made important contributions to optical emission spectroscopy in the early 1930’s;a broad patent ( 4 ) was issued that was subsequently licensed to a number of companies without charge, but with a provision for exchange of ideas on method improvements. One of the earliest installations of spectrographic equipment for routine materials analysis was set up in 1934 in an automotive company ( 5 ) . The dramatic growth of analytical instrumentation in this industry is illustrated by Figure 3. As shown, the use of infrared spectrometers has grown steadily, and they outnumber any other type of analytical instru-

ment. Not shown is the fact that they were outnumbered in the past by optical emission spectrographs, many of which have been replaced by direct reading instruments. Newer techniques, such as atomic absorption spectroscopy and scanning electron microscopy, also have impressive growth curves. In fewer numbers (not shown) are mass, nuclear magnetic resonance, and electron spectrometers. For a complete account of instrumentation used for the analysis of automotive materials, those used by suppliers should be added to those shown in Figure 3. I have no way of estimating the number of all of these instruments, but they surely represent an investment of many millions of dollars. With regard to the purchase and use o’f these instruments, consumerism (again) has two facets. First, the end use of the instruments is to support efforts on providing products that are satisfactory t o the customer. Second, consumerism comes to mind when we purchase an instrument after compar ing competitive instruments on the basis of resolution, sensitivity, versa-

tility, cost, and the like. Perhaps the best tribute to the manufacturers of analytical instrumentation is seen in the widespread and growing use of their equipment in so many areas important to all consumers. Growth of Infrared Spectroscopy. Let us continue by focusing on infrared spectroscopy, one of many analytical techniques used daily in automotive manufacturing plants for receiving inspection. One material inspected is engine oil, which contains antiwear agents, detergent-dispersants, oxidation inhibitors, rust and corrosion inhibitors, viscosity index improvers, and foam inhibitors. To ensure that a “factory fill” oil received from a supplier is the same as that approved after extensive tests in engines and cars, infrared spectra are obtained on shipments to detect deviations in the base oil and additive content. As a matter of direct consumer interest, the recommended interval for oil change has increased from 2,000 miles in 1950,’to two months (or 4,000 miles) in 1962, and to four months (or 6,000 miles) today. A fascinating account (3)of infrared

ANALYTICAL CHEMISTRY, VOL. 46, NO. 11, SEPTEMBER 1974

867A

IldlC"

aprGn"uc"yy

IVI

'LJ"'"C"'"""

analysis became apparent (6).Later, the first procedures were described for analyzing multicomponent liquid mixtures with concentrations of any of the components varying from 0 to 100%(7). Although all conscionable researchers keep societal benefits of their work in mind, the magnitude of these benefits may only become apparent much later. For example, in 1934 Max D. Liston, an electrical engineer in an automotive research laboratory, worked on the development of thermopiles and breaker-type de amplifiers for use in infrared detection systems 13). He later joined the Perkin-Elmer Corp. and designed a new double-heam recording spectrometer (8).Suhsequently, he formed his own company and developed an infrared nondispersive analyzer for monitoring automotive emissions. This instrument, manufactured by Beckman Instruments, Inc., is now widely used for determining whether exhaust emissions from a car are within prescribed emission limits. Present Applications T o single out a major difference between past and present activities, a major portion of today's effort is placed on examining samples with techniques so sensitive that many of the substances of interest can he found almost anywhere. This is also true elsewhere and applies, for exam868A

*

Figure 3. Growth of analytical instrumentation in automotive industry

ple, to traces of bismuth in steel, mercury in fish, phthalates in plastics, and impurities in semiconductors. Common to all of these examples is the need for complete regard for sampling and the analytical "blank". In some instances, unfortunately, analytical incompetence and premature conclusions have led to undue concern in matters of public interest, and scientific effort has been diverted from genuine problems. In other words, some irresponsible actions remind me of a remark said to have been made by one of the passengers on that famous hydrogen-filled zeppelin that was soon to hurst into flames, "I guess we're allowed to smoke." Just as we see today, there was action and reaction!

ANALYTICAL CHEMISTRY, VOL. 46, NU. 11. S t P T E M B t R 1 Y 1 4

Diverse Analytical Competences.

A list of the analyticalcompetences required in the industry would he quite extensive. Instead, shown in Table I is a list of research activities that depend on analytical chemistry services. T o help the industry respond to the demands of a rapidly advancing society, the dimensions and directions of research programs in these groups change continually. For example, analytical chemistry activities are closely associated today with increased emphasis on environmental science (sources, dispersal, and effects of pollutants), physical chemistry (catalysis), and polymers (aging effects and recycling).

Thinkof it as a clock -

in your day.

C:ompared with tl1Z leadiiig competitive analyzer, the- Beckman AMA 40 Automated Materials Analyzer-whose discrete chemistry table you see here-is an exceptional time saver. You don't use a lot of time preparing samples. for instance. AMA 40 prepares them for you. Then its assay rate is twice as fast as the other system, whatever the analysis, including even liquidliquid extractions. Moreover. you change from one analysis to another in 10 to 15 minutes. No cartridges to switch, and no need for many separate

dedicated systems. And with AMA 40 you can assay all the components in a single samplethat's true discrete analysis. Save big on reagents. too. AMA 40 uses about 1 liter per hour compared with 12 to 15 liters per hour in the competitive system. Which means you're not handcuffed by limited allocations of organic solvents. AMA 40's versatility also means savings. Use the instrument with virtually any analytical method, leading to most common analytical tools (IR. UV. GC, etc.).

and add new procedures at any time without added cost. Don't take our word alone, however. On request. we'll give you complete data plus references: the names of satisfied users in major laboratories who'll tell you why they prefer the Beckman AMA 40. Contact Jim Miller at (714) 833-0571, ext. 2207. or write to Scientific Instruments Division. P.O. Box D-W. Irvine, Calif. 92664.

AMA 40 Automated Materials Analyzer. CIRCLE 2 6 ON READER SERVICE CARD

ANALYTICAL CHEMISTRY, V O L . 46, NO. 11, SEPTEMBER 1974

869A

.. Table I. Research GroupsThat Require Analytical Chemistry Services Bionwwcil screr ce t.lcctrucncn~istiy Elect onics En issions research Cn.ironinenta science rdels imn lubricants Me!sll-ri/ Pci/s cal chemistry Pn,sics

Polymers

Oil Consumption Measurements of Engines. Requirements for materials, parts, and components are set forth in specifications to be met by suppliers. These separate specifications alone, however, do not guarantee the overall quality of the manufactured unit. Thus, reliable methods that test product performance are continually being developed and applied. As an example, product quality was improved by detecting and correcting the cause bf excessive oil consumption in some automotive engines on the assembly line. Although oil consumption has been measured by using a calibrated dipstick and a drain-and-weigh method, neither one is fast or accurate enough for in-plant measurements. A radiometric method (9) was developed that requires only a few minutes of engine running time to obtain an accurate measurement. In this method (Figure 4 ) oil containing a small amount of a radioactive bromine compound is added to the engine crankcase fill. As crankcase oil enters the combustion chamber during engine operation, the radioactive tracer is converted to hydrogen bromide and carried out with the exhaust gases. The exhaust gases are passed through canisters where the bromide is captured on porous pellets saturated with a sodium hydroxide solution. The amount of radioactivity collected in to the the canisters is DroDortional . . rate of engine oil consumption. Fifteen microcuries of bromine (an exemDt quantity pursuant to AEC regulations) are used, which provides the sensitivity for detecting the consumption of 1 quart of oil in 60,000 miles of vehicle operation. As another benefit, known defects (such as installing a compression ring upside down) can be introduced to measure their effect on oil consumption. Particle Size Measurements. The particle size analysis of colloidal or particulate matter is important in sev870A

Figure 4. Construction and location of canister (insert)used to trap radioactive bromine in measuring oil consumption of engines (9)

Figure 5. Optical system of laser light-scattering photometer ( 14

era1 areas of interest: paints and Dig.. ments, reinforcing fillers for elastomers and plastics, synthetic and natural latex, and pollution studies. Lowangle light scattering (forward lobe) is a particularly useful technique for these particle size analyses in the size range of about 0.05-50 fim. TOtake full advantage of this technique, an instrument was designed that features the use of lasers for high angular resolution, a single photon-counting system for providing precise digital data,

ANALYTICAL CHEMISTRY, VOL 46, NO 11. SEPTEMBER 1974

and an automated data collection and treatment system (10). A schematic of the optical system is shown in Figure 5 . Measurements in situ are provided, thus avoiding some of the inherent problems of measurements by microscopy. The method is independent of concentration over a wide range, rather insensitive to particle shape differences, and largely independent of refractive index. In one application the instrument was applied to latex ruhher matura-

Get higher productivity ratings with Thomas Spectroanalytical Systems. Productivity is the measure of success in the modern analytical laboratory. The number of laboratory samples processed per day regulates the quality of service which your hospital, your manufacturing plant, or your research facility can offer. Thomas Spectroanalytical Systems won’t measure productivity. Their job is to increase it.. .without a lot of personnel retraining and without heavy budget strain. A Thomas Spectro System can be built around your present spectrophotometer. Sampling modules to increase rate of sample throughput; direct concentration readouts to eliminate meter readings and conversion calculations; printout modules to provide a record of serial data without transcription errors; a peak detector to print maxima and minima automatically (no yards of curves to scan). If a new spectrophotometer seems indicated, we’ve got many models to choose from. 4 We can tailor the instrumentation package to meet your current needs, with built-in provision for extending capability, module-by-module, as future needs dictate. 4 Best of all, you increase productivity at no sacrifice of accuracy, preferred methodology, or ability to analyze the single stray sample that comes along. Let a Thomas Spectro Specialist show you the spectro accessories we’ve devised to boost analytical productivity. Arthur H. Thomas Company, Vine Street at Third, Philadelphia, Pa. 19105.

ARTHUR H m

THOMAS COMPANY

CIRCLE 125 ON READER SERVICE CARD

tion studies (11).Basic information was provided on the relationship hetween processing variables and the physical-chemical changes occurring during the precure stage. Elemental Analysis of Atmospheric Aerosols. Measurement of daily variations of individual elements in the atmosphere can be used to determine the sources of pollution. Filters of small pore size (