Anomalous Pull-Off Forces between Surfactant-Free Emulsion Drops

Faculty of Life and Social Sciences, Swinburne University of Technology, Hawthorn, VIC 3122, Australia ...... Henry , C. L.; Craig , V. S. J. Phys. Ch...
0 downloads 0 Views 2MB Size
Article pubs.acs.org/Langmuir

Anomalous Pull-Off Forces between Surfactant-Free Emulsion Drops in Different Aqueous Electrolytes Hannah Lockie,†,§ Rogerio Manica,‡ Rico F. Tabor,†,§ Geoffrey W. Stevens,† Franz Grieser,§ Derek Y. C. Chan,∥,⊥ and Raymond R. Dagastine*,†,# †

Department of Chemical and Biomolecular Engineering and the Particulate Fluids Processing Centre, §School of Chemistry and the Particulate Fluids Processing Centre, and ∥Department of Mathematics and Statistics and the Particulate Fluids Processing Centre, The University of Melbourne, Parkville, VIC 3010, Australia ‡ Institute of High Performance Computing, 1 Fusionopolis Way, 138632, Singapore ⊥ Faculty of Life and Social Sciences, Swinburne University of Technology, Hawthorn, VIC 3122, Australia # Melbourne Centre for Nanofabrication, 151, Wellington Road, Clayton, Victoria 3168, Australia ABSTRACT: A systematic study of collisions between surfactant-free organic drops in aqueous electrolyte solutions reveals the threshold at which continuum models provide a complete description of thin-film interactions. For collision velocities above ∼1 μm/s, continuum models of hydrodynamics and surface forces provide a complete description of the interaction, despite the absence of surfactant. This includes accurate prediction of coalescence at high salt concentration (500 mM). In electrolyte solutions at intermediate salt concentration (50 mM), drop−drop collisions at lower velocity (99% (Sigma Aldrich) and column purified twice using Florosil 100−200 mesh (Sigma Aldrich). Salts of >99.9% purity (Sigma Aldrich) were baked at 50 °C below their respective melting points for a minimum of 7 h to remove any organic contamination and used immediately. Solutions were prepared with Milli-Q purified water (resistivity of 18.2 MΩ cm). All glassware was carefully cleaned with Ajax soaking, nitric acid soaking, and thorough rinsing with Milli-Q purified water. 2.3. Interfacial Tension. Interfacial tension was obtained ex situ from the pendant drop geometry measured using a Dataphysics OCA 20 tensiometer. For all tetradecane drops in pure water, or aqueous electrolyte solutions of 2−100 mM concentration (with a range of monovalent salts), an interfacial tension of 54 ± 2 mN/m was measured, indicating purity of the oil−water system. Changes in interfacial tension due to ion-type or concentration were not observed, possibly due to the limited precision of the measurement technique. The interfacial tension of tetradecane drops in electrolyte (50 mM NaNO3) solutions with 30% and 40% sucrose was measured as 40 ± 2 and 37 ± 2 mN/m, respectively, indicating some degree of interfacial activity of the sucrose species. Interfacial tensions of hexadecane and 3:1 mixtures of hexadecane and tetradecane showed no deviation from tetradecane interfacial tension (within experimental resolution), with values of 54 ± 2 mN/m also measured in water and 50 mM NaNO3, also indicating purity. Octyl acetate drops in water and a range of electrolyte solutions and concentrations (