Collection of Ammonia for High Time-Resolved Nitrogen Isotopic Characterization Utilizing an Acid-Coated Honeycomb Denuder Wendell W. Walters, and Meredith G. Hastings Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.8b01007 • Publication Date (Web): 12 Jun 2018 Downloaded from http://pubs.acs.org on June 13, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
Collection of Ammonia for High Time-Resolved Nitrogen Isotopic Characterization Utilizing an Acid-
2
Coated Honeycomb Denuder
3
Wendell W. Walters*†,‡ and Meredith G. Hastings†,‡
4
†
5
Providence, RI 02912.
6
‡
7
02912
Department of Earth, Environmental, and Planetary Sciences, Brown University, 324 Brook Street,
Institute at Brown for Environment and Society, Brown University 85 Waterman Street, Providence, RI
8
9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25
*Corresponding author:
[email protected] 26 1 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 2 of 27
27
Abstract.
28
Nitrogen stable isotope analysis (δ15N) of ammonia (NH3) has shown potential to be a useful tool for
29
characterizing emission sources and sink processes. However, to properly evaluate NH3 emission sources
30
and sink processes under ambient conditions it is necessary to collect and characterize the chemical
31
speciation between NH3 and particulate ammonium (p-NH4+), together referred to as NHx. Current NH3
32
collection methods have not been verified for their ability to accurately characterize δ15N-NH3 and/or
33
provide necessary chemical speciation (i.e., δ15N-NH3 and δ15N-NH4+). Here, we report on the suitability
34
of an established collection device that can provide NHx speciation, an acid-coated (2% citric acid (w/v) +
35
1% glycerol (w/v) in 80:20 methanol to water solution) honeycomb denuder (HCD) with a downstream
36
filter pack housed in the ChemComb Speciation CartridgeTM (CCSC), for characterizing δ15N-NH3 under
37
a variety of laboratory-controlled conditions and field collections. The collection method was tested under
38
varying NH3 concentration, relative humidity, temperature, and collection time at a flow rate of 10 liters
39
per minute (LPM). The acid-coated HCD collection device and subsequent chemical processing for δ15N-
40
NH3 analysis is found to have excellent accuracy and precision of ±1.6‰ (2σ), with an operative capacity
41
of ~400 µg of collected NH3 for concentrations ≤207 ppbv. This work presents the first laboratory
42
verified method for δ15N-NH3 analysis and will be useful in future air quality studies.
43 44 45 46 47 48 49 50 51 52
2 DRAFT
ACS Paragon Plus Environment
Page 3 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
53
Introduction
54
Ammonia (NH3) is the primary alkaline molecule in the atmosphere and plays a key role in numerous
55
atmospheric processes that have important implications for human health and climate via new particle
56
nucleation1,2. Understanding NH3 emission sources and sink processes, especially in urban areas, is a
57
challenging task due to the coexistence of many locally produced sources including emissions from local
58
traffic3–6, fuel combustion, industrial processes, humans7–11, and transport of agricultural NH312–14.
59
Analysis of the stable isotope composition of trace gases is an established tool for quantifying emission
60
sources,15 as various surface sources and sink processes often exhibit characteristic isotopic compositions
61
(“fingerprints”).16 This tool allows for an understanding of emission sources as well as means to track the
62
chemical and physical processes responsible for removal of trace gases at a process level. Previous
63
researchers have used this technique to evaluate contributions of various sources and sink processes of
64
numerous relatively-long lived trace gases including methane (CH4),17,18 carbon dioxide (CO2),19,20 carbon
65
monoxide (CO),21,22 and nitrous oxide (N2O).23,24 Applying this tool to relatively-short lived NH3 might
66
also enable an evaluation of its emission sources and sink processes, providing distinct information
67
amidst large spatial and temporal variabilities. Previous measurements of the nitrogen (N) stable isotope
68
composition of NH3 (δ15N-NH3)1 emission sources have reported large NH3 source δ15N variability and
69
suggest considerable overlap between various emission sources (Fig. 1)25–31. However, some of these
70
observations also include NH3 process driven δ15N effects, such as NH3 volatilization resulting in a
71
gradual increase in δ15N. Thus, there is a need to better diagnose δ15N values associated with emissions
72
sources, while also constraining chemical or physical process effects.
73 74
1
δ15N(‰) = [(15Rsample)/(15Rreference) – 1] × 1000, where 15R is the ratio of 15N/14N and air N2 is the N isotopic reference.
3 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 4 of 27
75 76 77
Fig. 1. Previously reported δ15N-NH3 values of NH3 source emissions and NH3 volatilization (e.g.
78
fertilizer and animal waste)25–31.
79
techniques (legend), and many sources and process driven effects (NH3 volatilization) show large
80
variations in δ15N-NH3. Coal-fired power plants are indicated as CFPP.
Prior measurements have used a wide variety of NH3 collection
81 82
Numerous collection techniques have been used to collect NH3 as NH4+ for off-line N isotopic analysis
83
including wet scrubbers25–27, passive diffusion samplers31,34, an acidic absorbing solution contained within
84
an evacuated gas sampling bulb28, and active sampling using acid impregnated filters29,30 (Fig. 1). While
85
these methods have been designed to accurately reflect NH3 concentrations, they have not been
86
laboratory-verified for their suitability for δ15N-NH3 analysis; therefore, the δ15N accuracy and/or
87
precision of these collection devices are uncertain. The potential for collection methods to impact δ15N-
88
NH3 was highlighted in Skinner et al., (2006), in which a comparison between several active and passive
89
NH3 collection devices including gas-scrubbing bubbler, moss bag, shuttle sampler, and diffusion tube
90
revealed significantly different δ15N-NH3 values and variances even when sampling the same emission 4 DRAFT
ACS Paragon Plus Environment
Page 5 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
91
source (field fumigation site). This result, and the contrasting reported environmental values, questions
92
the accuracy of previously reported δ15N-NH3 values.
93 94
An additional complication when sampling ambient air for δ15N-NH3 analysis is that NH3 exists in
95
thermodynamic equilibrium with nitric acid (HNO3), hydrochloric acid (HCl), and their neutralized
96
condensed phases including ammonium nitrate (NH4NO3) and ammonium chloride (NH4Cl)35–40. NH3
97
will also neutralize sulfuric acid (H2SO4), but due to the low vapor pressure of its product ammonium
98
sulfate ((NH4)2SO4), it resides nearly completely in the condensed phase40. The coexistence of NH3 and
99
NH4+, together referred as NHx, makes it possible that N isotopic equilibrium between NH3 and NH4+
100
could occur25,29, which will scramble the 14N and 15N isotopes between NH3 and NH4+ based on statistical
101
mechanics41:
102
+ ⇌
+
(R1)
103
The theoretical equilibrium constant (K) or isotopic fractionation factor (α) for R1 is 1.034 ± 0.002 at
104
298.1 K41, indicating that isotopic equilibrium will favor the partitioning of 15N into p-NH4+, resulting in
105
higher δ15N values in p-NH4+ than in NH3 (Eq. 1).
106
. = . =
= 1.034 ± 0.002
(Eq. 1)
107
Additionally, unidirectional neutralization reactions involving NH3 and H2SO4 have been suggested to
108
result in a kinetic isotope effect leading to the initial δ15N of p-NH4+ to be -28‰ relative to ambient NH3
109
based on relative diffusion rates of 14NH3 and 15NH342. Therefore, speciated δ15N measurements of NHx
110
could provide valuable information about NH3 gas to particle conversion and new particle formation,
111
indicating whether p-NH4+ is formed under either kinetic or equilibrium controlled processes. Due to the
112
potential for δ15N of ambient NH3 to be altered during particle formation, it is critical that under ambient
113
air sampling conditions the collection technique must allow for the speciation of NHx to evaluate the
5 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 6 of 27
114
impact of NH3 neutralization reactions/thermodynamic equilibrium on δ15N-NH3. The denuder-filter
115
combination is an established NH3 sampling technique that will effectively speciate NHx43–49. In this
116
system, NH3 is first removed from the sampled air stream on an acid-coated glass denuder followed by
117
collection of p-NH4+ on a downstream filter pack. These methods have been in use for decades using
118
several denuder geometries including a simple boroscillate tube43, honeycomb denuder44,45, and annular
119
denuder46,50 geometries to measure NHx concentrations12,48,51–53.
120 121
Here we present a new application of the denuder-filter sampling technique for characterizing δ15N-NH3.
122
We have extensively tested a commercially available honeycomb denuder coated with an acid solution
123
and housed in a ChemComb Speciation CartridgeTM, which has been well-characterized for its ability to
124
speciate gas and particulate matter components44,45, for its suitability for δ15N-NH3 analysis under a
125
variety of simulated environmental conditions and field collections. This work is a crucial step in
126
developing a record of reliable δ15N-NH3 measurements. Ultimately, a field deployable method suitable
127
for δ15N-NH3 analysis and capable of achieving high time-resolved measurements will help make
128
considerable progress on evaluating spatial and temporal variability in environmental NH3 emission
129
sources and sink processes.
130 131
Experimental Section
132
NH3 Collection Using an Acid-Coated Honeycomb Denuder. NH3 is collected on a honeycomb
133
denuder (HCD) coated with a 2% citric acid (w/v) 1% glycerol (w/v) in an 80:20 methanol to ultra-high
134
purity water (18.2 MΩ, Milli-Q (MQ)) solution and housed in a ChemComb Speciation CartridgeTM
135
(CCSC). We note that a range of acid coating solutions may be used to capture NH3 including phosphoric
136
acid and oxalic acid50; however, we have limited our tests to citric acid due to its low [NH4+] blanks
137
compared to other acids43, making it more suitable for environmental research and the need for high-time 6 DRAFT
ACS Paragon Plus Environment
Page 7 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
138
resolved measurements. The employed sampling system has been extensively described and characterized
139
in previous works44,45. Briefly, the CCSC contains a polytetrafluoroethylene (PTFE) coated inlet to limit
140
NH3 loss (previous work has found this inlet to have an NH3 transmission efficiency greater than 97.3%
141
utilizing this PTFE coating54) and a PTFE coated stainless steel PM2.5 impactor that removes particulate
142
matter larger than 2.5 µm and facilitates an evenly distributed flow through the 212 hexagonal channels of
143
the HCD at a flow rate of 10 liters per minute (LPM). The indented circular reservoir of the impactor
144
plate was evenly covered with PTFE grease (Chemours Krytox GPL 207) to prevent particle bounce and
145
to limit NH3 absorption. Within the CCSC, a borosilicate transition piece allows laminar flow to be
146
achieved followed by two acid-coated HCDs in series that are separated by a PTFE spacer. The first
147
“capture” HCD is used to remove NH3 from the sampled airstream, and the second HCD is used as
148
control to check for possible NH3 breakthrough in our control tests. After the HCD, there is an available
149
filter pack within the CCSC to collect particulate matter on a filter, though this was not used during our
150
control tests of NH3 collection. An image of the sampling apparatus is provided in the Supporting
151
Information (Fig. S1).
152 153
NH3 Collection Experiments. The laboratory NH3 collection set-up is depicted in Fig. 2. Briefly, a 20.7
154
(±1%) ppmv flow of NH3 in N2 tank (Praxair) was controlled using a mass-flow controller. This tank was
155
diluted to achieve variable [NH3] using the laboratory N2 compressed gas line that was further purified
156
using Molecular Sieve 5Å and Silica Gel. NH3 was not detectable in the purified N2 gas line. The N2
157
compressed gas line was divided using a 3-way union fitting made from PTFE with one of the lines
158
passing through a gas-washing bottle containing MQ water and then through a water trap, allowing for
159
separate N2 lines containing “wet” N2 and “dry” N2. The flow rates of wet N2 and dry N2 were controlled
160
using separate rotameters. Altering the relative flow rate of wet N2 to dry N2 allowed for testing various
161
levels of relative humidity (RH). The flow of wet N2 and dry N2 were combined using a PTFE 3-way
162
union fitting. The total N2 flow was then combined with the flow from the NH3 tank using another 3-way 7 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 27
163
PTFE union fitting that was also connected to the inlet of the CCSC. The outlet of the CCSC was
164
connected to a rotameter to ensure that “in-flow” was approximately equal to the “out-flow”, and
165
temperature(±0.5°C) and RH(±3%) were monitored in the excess out-flow (Elitech GSP-6). Due to the
166
reactiveness or “stickiness” of NH3 with surfaces, all tubing in our setup was composed of polyvinylidene
167
fluoride (PVDF), which has been shown to be chemically inert to NH355.
168 169
Fig. 2. Schematic diagram of the experimental setup for the evaluation of NH3 collection using an acid-
170
coated honeycomb denuder housed in the ChemComb Speciation CartridgeTM. The sample lines were
171
made of polyvinylidene fluoride, and the three-way union connectors were made from PTFE to limit the
172
absorption of NH3.
173 174
The sampling cartridge is designed for an optimal flow rate of 10 LPM44, so all experiments were
175
conducted at this flow rate. Variable “target” NH3 concentrations ([NH3]) were tested including 31.3,
176
107, 207, and 2070 ppbv; however, we note the possibility that the [NH3] in the gas tank may not be as
177
accurate as reported, and that NH3 loss in the sampling line may lower the actual flowed [NH3]. The
178
targeted [NH3] encompass a range somewhat typical of what is expected for a range of environmental
179
sampling conditions, including near emission sources and ambient air. Ambient conditions will likely
8 DRAFT
ACS Paragon Plus Environment
Page 9 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
180
have [NH3] lower than 31.3 ppbv (e.g. near single ppbv levels)51, but this was the lowest concentration we
181
could achieve given a mass flow controller minimum flow rate of 0.015 LPM. However, this should not
182
limit our evaluation of the applicability of this collection technique because denuders are limited by high
183
concentrations of the gases to be denuded44, such that lower concentrations should be denuded as
184
efficiently as the higher tested concentrations. NH3 flow tests were also conducted over a variety of
185
temperatures by placing the sampling cartridge and inlet in an ice bath and heating the sample line and
186
cartridge using heat tape to test the NH3 collection efficiency under a variety of environmentally-relevant
187
temperatures. After NH3 collection, the HCD and single-channel denuder tube were extracted using 30
188
mL of MQ water. NH4+ blanks in the extraction solution were always found to be less than 0.3 µM-NH4+
189
(n = 12), near our analytical detection limit (see below).
190 191
Due to NH3 reactiveness with surfaces, we also evaluated the CCSC as a source of NH3 loss (e.g. PTFE
192
coated inlet and PTFE coated impactor plate) and a potential source for δ15N-NH3 fractionation. This was
193
tested by collecting NH3 using a perfluoroalkoxy (PFA) gas-scrubbing impinger containing 30 mL of a
194
2% citric acid solution connected in series with a second PFA impinger to check for breakthrough. These
195
control tests were conducted at an [NH3] of 2070 ppbv, a flow rate of 1 LPM, and for a collection time of
196
5 minutes. An impinger with an acidic scrubbing solution is an established efficient collector of NH3 (e.g.
197
U.S. EPA Method 17), but does not adequately provide the speciation of NHx that suits our needs for
198
δ15N-NH3 determination in ambient air. After NH3 collection the solution contained within the gas
199
scrubbing impinger were transferred to a 50-mL centrifuge tube and stored in a refrigerator until future
200
concentration and isotope analysis.
201 202
[NH4+] Concentration and δ15N Isotopic Analysis. All collected NH4+ samples were analyzed for their
203
concentration using colorimetric analysis based on the indophenol blue method56 that was automated
9 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 10 of 27
204
using a discrete UV-Vis analyzer (Westco SmartChem 2.0). Reproducibility calculated from replicate
205
measurements was ±0.5 µM-NH4+. The determination of δ15N-NH4+ follows previously described
206
methods57. Briefly, samples are diluted to at least 10 µM-NH4+ using MQ water to a volume of 10 mL in
207
50 mL vials that are acid-washed, triple-rinsed with MQ water, and ashed at 500 °C for 4 hours. The
208
samples are then oxidized to nitrite (NO2-) using hypobromite (BrO-) in an alkaline solution, which was
209
synthesized as previously described in Zhang et al., (2007). Since accurate isotopic measurements are
210
sensitive to the conversion of NH4+ to NO2- (i.e. incomplete conversion would lead to undesirable δ15N
211
fractionation)57, reaction conditions including volume of the oxidation solution and reaction time were
212
optimized for our sample matrix. [NO2-] oxidation yields were measured using a standard colorimetric
213
absorption technique (e.g. US EPA Method 353.2) automated using a discrete UV-Vis analyzer (Westco
214
SmartChem 2.0). Reproducibility based upon replicate measurements of samples and quality control
215
standards was found to be ±0.3 µM-NO2-. Next, 0.4 mL of 0.4 M sodium arsenite (NaAsO2) was added to
216
the samples to remove remaining BrO-.
217 218
Once the NH4+ samples are converted to NO2-, they can be routinely analyzed for their N isotopic
219
composition using previously established chemical methods that convert NO2- to N2O57,58. Briefly, 20
220
nmol of NO2- samples are transferred to 20 mL vials that were acid-washed, triple-rinsed with MQ water,
221
and ashed at 500 °C for 4 hours. Vials are crimp capped with PTFE/butyl septa and flushed with helium
222
(He) for 10 minutes. NO2- is subsequently reduced to N2O using 2 mL of 1M sodium azide buffered in
223
30% acetic acid solution58. Subsequently, the solutions are neutralized using 6M NaOH with a 0.1%
224
phenolphthalein solution to indicate when the solutions reached pH > 8.2, which is done to limit the
225
possibility of toxic hydrazoic acid (HN3) from escaping into the laboratory. Samples are then analyzed
226
for their δ15N-N2O composition using an automated N2O extraction system coupled to a continuous flow
227
Isotope Ratio Mass Spectrometer for m/z 44, 45, and 46 measurements59. In each sample batch,
228
unknowns are calibrated with respect to two internationally recognized NH4+ isotopic reference materials, 10 DRAFT
ACS Paragon Plus Environment
Page 11 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
229
IAEA-N2 and USGS25, with δ15N values of 20.3‰, and -30.3‰, respectively60,61, that are run between
230
approximately every 10 unknowns. The isotopic standards undergo the exact same chemical processing
231
as the unknowns and are used to correct for isotopic fractionation resulting from the chemical conversion
232
of NH4+ to N2O. For each batch sample analysis, replicates of two NO2- standards with known isotope
233
values (RSIL-N7373 and RSIL-N10219 with δ15N = -79.6‰ and 2.8‰, respectively)62 are run as a
234
quality control to monitor the conversion of NO2- to N2O and system stability. Corrections to determine
235
δ15N-NH4+ are performed by accounting for isobaric influences, blank effects, and calibrating the
236
unknowns to the internationally recognized δ15N-NH4+ standards.
237 238
Results and Discussion
239
The evaluation of the performance of a collection method for the isotopic analysis of a reactive gas should
240
involve a check of the following parameters (adapted from Perrino et al., 1990):
241
1. Matrix suitable for isotopic analysis. The matrix of the collection reagent must be suitable for
242
the processing associated with converting the collected reaction product to an appropriate form
243
for isotopic analysis.
244 245 246
2. Collection efficiency. The collection method must be shown to be a quantitative sink for the target analyte to limit an isotopic bias. 3. Selectivity of the collection method. The collection method should only retain the target analyte
247
and no other compounds should yield the same reaction product. This is expected to be a trivial
248
requirement for NH3 since it is the primary inorganic alkaline gas50.
249
4. Known operative capacity. The operative capacity (defined as the amount of target analyte that
250
can be collected while maintaining a collection efficiency >95%)63 must be known for the
251
intended sample collection duration.
11 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
252 253 254
5. Stability of reaction product. The collected reaction product should not be released or compromised once collected. 6. Comparison to other collection devices. Generally, there are no internationally recognized
255
isotopic standards for reactive gases. Therefore, the potential bias of the collection device,
256
primarily inlet loss, needs to be evaluated. For example, by comparison with other collection
257
devices in which this bias is expected to be low.
258 259
Page 12 of 27
7. Field applicability. Field applicability of the collection method should be demonstrated for the intended sample collection times with collection performed in replicates.
260 261
Matrix effect on NH4+ oxidation. The limiting step in δ15N-NH4+ analysis utilizing methods described in
262
Zhang et al., 2007 is the oxidation of NH4+ to NO2-. Thus, we evaluated the impact of our sample matrix,
263
2% citric acid + 1% glyercol coating solution extracted in 30 mL of MQ, on the conversion of NH4+ to
264
NO2- for a variety of reaction parameters including variable BrO- amounts and reaction times. Solutions
265
containing 10 mL of 10 μM-NH4+ were created using either the sample matrix or MQ water and were
266
oxidized using either 1 or 2 mL of the alkaline BrO- solution. Triplicates were performed for each unique
267
matrix and BrO- volume combination. Fig. 3 displays the NO2- oxidation yields that were measured as a
268
function of time ranging from 0.2 to 31.5 hours. Quantitative NH4+ to NO2- oxidation is found in our
269
sample matrix for both 1 and 2 mL additions of the alkaline BrO- solution, and complete oxidation is
270
achieved in as early as 20 minutes (Fig. 3). Additionally, quantitative conversion was found to be
271
maintained for up to 31.5 hours, indicating [NO2-] stability in the oxidation solution (Fig. 3). Therefore, it
272
is our recommendation that 1 mL of the alkaline BrO- solution is enough to ensure complete NH4+
273
oxidation to NO2- for a 20-minute reaction time in a 10-mL solution containing 10-µM of NH4+. Since
274
incomplete NH4+ to NO2- oxidation would result in an undesirable isotope effect, it is also our
275
recommendation that oxidation yields should be checked for each sample. Once converted to NO2-,
276
samples can be readily reduced to N2O using azide in an acetic acid buffer as previously described57,58. 12 DRAFT
ACS Paragon Plus Environment
Page 13 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
277
We find δ15N-NH4+ for isotopic standards in the sample matrix to have a standard deviation of 0.6‰ and
278
0.7‰ (1σ) for IAEAN2 (n = 29) and USGS25 (n = 27), respectively, resulting in an overall pooled
279
standard deviation of 0.7‰. Overall, these results demonstrate the sample matrix to be suitable for δ15N-
280
NH4+ analysis.
281 282
Fig. 3. Effect of reaction time, BrO- volume addition, and sample matrix on the oxidation of NH4+ to
283
NO2- and stability of the NO2- reaction product. Quantitative oxidation is achieved within 20 minutes for
284
both 1 and 2 mL additions of BrO-, and the NO2- product is stable for at least 31.5 hours.
285 286 287
NH3 Collection Performance. The collection efficiency of the 2% citric acid + 1% glycerol coated HCD
288
for NH3 capture for varying sampling conditions is displayed in Fig. 4. Collection efficiency (E; Eq. 2)
289
and total recovery (Q; Eq. 3) were calculated according to:
290
! = 100"1 # $ ⁄$ &
(Eq. 2)
291
$'(' = $ + $
(Eq. 3) 13
DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 14 of 27
292 293
Where 1 and 2 refer to the capture and breakthrough denuder, respectively. Overall, NH3 collection
294
efficiency was found to be higher than the 95% threshold63 under most sampling conditions for a
295
collection amount up to 388.8 µg of NH3, except for the flow tests at an extremely elevated [NH3] of 2070
296
ppbv (Fig. 4). At this elevated [NH3], collection efficiency was observed to quickly diminish after an NH3
297
collection amount of 14.8 µg. This result is consistent with Koutrakis et al. 1993, that found the acid
298
coated HCD to be best suited for an [NH3] lower than 200 ppbv. Our results indicate excellent NH3
299
collection efficiency between 1.3 to 388.8 µg-NH3 for a collection time up to 24 hours (Table S1). Since
300
we found collection efficiency to deteriorate for NH3 collection amounts greater than 388.8 µg of NH3
301
(Fig. 4), we suggest this amount as the operative capacity of the collection system.
302 303
The measured δ15N-NH3 for the NH3 capture tests are also shown in Fig. 4. When collection efficiency is
304
found to be >95%, we find reproducible δ15N-NH3 values with a 2σ of ±1.6‰ (n = 75). Interestingly, the
305
measured 2σ is very close reproducibility of our NH4+ isotopic standards of 1.4‰ (2σ), suggesting that
306
the limiting factor in our analysis is the off-line processing for δ15N analysis rather than NH3 collection.
307
When collection efficiency is less than 95%, we observe an undesirable δ15N-NH3 isotope effect (Fig. 4);
308
thus, it is critical to stay within the operative capacity of the tested NH3 collection device. Based on
309
ANOVA single factor analysis, we find no statistical differences in δ15N-NH3 for any of the simulated
310
conditions when collection efficiency is >95% (p-value is 0.97), suggesting that the tested collection
311
technique is suitable for a variety of environmental conditions (i.e. temperature and relative humidity)
312
except for elevated [NH3] (e.g. >2000 ppbv). We note that we do not know the absolute δ15N-NH3 value
313
of our NH3 tank, but comparison with other collection devices can indicate any potential sampling
314
artifacts that might bias our δ15N-NH3 values such as NH3 loss on the sampling cartridge inlet (see
315
below).
14 DRAFT
ACS Paragon Plus Environment
Page 15 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
316 317 318
Fig. 4. Summary of NH3 capture data utilizing a 2% citric acid + 1% glycerol coated honeycomb denuder
319
(HCD) and a gas scrubbing impinger containing a 2% citric acid solution (GSI) including (a) NH3
320
collection efficiency (%) as a function of amount of collected ammonia (µg) from laboratory flow tests
321
for a range of [NH3] and (b) measured δ15N-NH3 as a function of collection efficiency for the laboratory
322
flow tests. Collection efficiency of 95% (minimum target) is indicated as the solid black line. When NH3
323
collection efficiency was found to be >95%, the measured δ15N-NH3 was found to be (x̄±2σ) -2.5±1.6‰
324
(n=75) and -2.4±2.0‰ (n=5) for the HCD and GSI, respectively.
15 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 16 of 27
325 326
Stability of Collected NH4+. Previous work utilizing a 1% citric acid coating solution found significant
327
NH3 desorption as high as 41% after 12 hours, which could severely limit its use for atmospheric
328
sampling for extended periods of time50. We tested for this possibility in our tested sampling system by
329
loading approximately the same amount of NH3 on several denuders and immediately extracted the NH4+
330
reaction product as well as waited 24 and 72 hours before extraction. This test was conducted in
331
triplicates for each extraction time, and the extracted [NH4+], δ15N-NH3, and calculated desorption loss are
332
displayed in Table 1. Based on the average of the three replicates for each test condition, we estimate a
333
desorption of 1.8% and 3.6% for 24-hr and 72-hr, respectively. However, we find no statistical
334
differences between QTOT, E(%), or δ15N-NH3 between the immediately extracted samples and those that
335
were extracted after 24 and 72 hr. This suggests that NH3 desorption in our sampling system and coating
336
solution is minimal for a period up to 72 hours. Both our flow tests and Koutrakis et al., 1993 found an
337
NH3 collection efficiency of >99.5% for 24-hour flow times, further suggesting that the 2% citric acid +
338
1% glycerol coating solution on a HCD should be sufficient for extending sampling periods (up to at least
339
24 hours). While we can only speculate on differences in NH3 desorption between our work and Perrino
340
and Gherardi, 1999, we can point out that we have tested a HCD coated with a 2% citric acid + 1%
341
glycerol solution while Perrino and Gherardi, 1999 performed their testing using an annular denuder
342
coated with a 1% citric acid solution.
343 344 345 346
16 DRAFT
ACS Paragon Plus Environment
Page 17 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
347
Table 1. Summary of the results of NH3 desorption following capture on a 2% citric acid +1% glyercol
348
coated HCD. Values are displayed as averages (±1σ) for triplicates and indicate the amount of collected
349
NH3 (QTOT), collection efficiency (E), δ15N-NH3, and calculated percentage of desorbed NH3.
350
Elapsed QTOT (µg) E(%) Time (hr) 11.2 ± 1.2 98.5 ± 0.1 0 11.0 ± 0.8 97.8 ± 0.3 24 10.8 ± 0.7 98.0 ± 0.7 72 * calculated as 100"1 # $)*)"+ ,- . /-& $)*)"0 /-& )
δ15NNH3(‰) -2.9 ± 0.5 -2.7 ± 0.6 -2.3 ± 0.3
Desorbed amount (%)* -1.8 3.6
351 352
Comparison to other NH3 Collection Devices. Collection efficiencies and δ15N-NH3 for the gas-
353
scrubbing impinger (GSI) are also displayed in Fig. 4. Overall, collection efficiency was always found to
354
be greater than 99.2% and δ15N-NH3 were found to be -2.4±2‰ (±2σ), respectively, for 5 trials (Table
355
S2). The measured δ15N-NH3 are found to be in statistical agreement with the measured δ15N-NH3 from
356
the acid-coated HCD housed in a CCSC (-2.7±1.6‰) when collection efficiency was >95% (Fig 2). This
357
comparison indicates that similar δ15N-NH3 values were achieved for the various NH3 collection devices,
358
suggesting that the CCSC housing is not a significant source of NH3 loss and does not impart a δ15N-NH3
359
bias compared to other collection devices in which inlet loss is assumed to be negligible.
360 361
Field Applicability. Ambient urban air in Providence, RI, USA was sampled in replicates (side-by-side
362
collections) for varying times including 1 (n=3), 24 (n=5), and 48 (n=4) hours by flow-controlling an air
363
sampling pump attached to the outlet of the CCSC to 10 LPM (Table S3). Collection efficiency was
364
found to be >98% for each sampled time interval (Fig. 4), further indicating minimal NH3 desorption for
365
sampling periods up to 48 hours utilizing our collection approach. The collected NH3 amount ranged
366
from 1.7 to 66.9 µg of NH3, which is well-within the tested operative capacity (~400 µg of NH3) of the
367
collection device (Fig. 4). Average reproducibility, calculated as the average of absolute differences 17 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 18 of 27
368
between the collected replicate samples for NH3 and δ15N-NH3, is 0.010 ± 0.008 µmol/m3 and 0.9±0.7‰,
369
respectively. Additionally, the average percent error between replicate concentration measurements is
370
found to be 16.9 ± 9.3%. The observed average reproducibility in δ15N-NH3 is close to our recommended
371
2σ error for this method of ±1.6‰ based on our laboratory control tests. The interpretation of the
372
measured δ15N-NH3 is beyond the scope of this work; however, these samples show that the tested
373
method allows for high-time resolution (on order of an hour) and reliable δ15N-NH3 measurements for
374
sampling periods up to 48 hours. We note that the collection time resolution of this method is dependent
375
upon achieving a minimum needed for isotopic analysis. For this study, 20 nmol samples were processed,
376
therefore requiring a minimum of 0.34 µg of NH3 for field collections.
377 378
Conclusion
379
We have critically evaluated a 2% citric acid + 1% glycerol coated HCD for its suitability for δ15N-NH3
380
analysis that has included a careful consideration of reagent blanks, matrix effects, collection efficiency,
381
selectivity, operative capacity, reaction product stability, and isotopic bias. Our results indicate the tested
382
method to be appropriate for δ15N-NH3 determination with a precision of ±1.6‰ (2σ; n = 75), for an
383
operative capacity (collection efficiency > 95%) of ~400 µg of collected NH3. Our field tests indicate
384
that the collection method is suitable for δ15N-NH3 characterization of ambient air with δ15N-NH3
385
resolution on the order of an hour. The high time resolution and excellent δ15N-NH3 precision of this
386
method will be applied in future work to improve our understanding of NH3 emission sources, sink
387
processes, and diurnal patterns of NH3. Additionally, the denuder-filter pack combo collection technique
388
has the potential to be extended for isotopic analysis of other gaseous compounds such as sulfur dioxide
389
(SO2), nitric acid (HNO3), and nitrogen dioxide (NO2) using an appropriate HCD coating for quantitative
390
gas collection. Utilizing the acid-coated HCD for NH3 collection, a carbonate-coated HCD for acidic gas
391
collection (e.g. HNO3 and SO2), and an appropriate filter for PM2.5 collection could enable the
18 DRAFT
ACS Paragon Plus Environment
Page 19 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
392
simultaneous determination of δ15N-NH3 and δ15N-NH4+(p) and a new tool for investigating the
393
atmospheric dynamics of NHx.
394 395 396 397
Acknowledgements. W.W.W. acknowledges support from an Atmospheric and Geospace Sciences
398
National Science Foundation Postdoctoral Fellow (Grant # 1624618) during the course of this study. This
399
research was also supported by funding to M.G.H. from the National Oceanic and Atmospheric
400
Administration (AC4 Award NA16OAR4310098) and the National Science Foundation (AGS 1351932).
401
We thank Ruby Ho and Nadia Colombi for laboratory assistance.
402 403
Supporting Information. Sampling apparatus image (Fig. S1). Summary of honeycomb denuder
404
control tests (Table S1). Summary of gas scrubbing impinger control tests (Table S2). Summary of
405
ambient air replicate samples (Table S3).
406 407
References
408 409 410 411 412 413 414 415 416 417 418 419
(1) (2)
(3) (4)
(5)
Asman, W. A.; Sutton, M. A.; Schjørring, J. K. Ammonia: Emission, Atmospheric Transport and Deposition. New Phytol. 1998, 139 (1), 27–48. Ianniello, A.; Spataro, F.; Esposito, G.; Allegrini, I.; Rantica, E.; Ancora, M. P.; Hu, M.; Zhu, T. Occurrence of Gas Phase Ammonia in the Area of Beijing (China). Atmospheric Chem. Phys. 2010, 10 (19), 9487–9503. Matthew Fraser; Cass, G. Detection of Excess Ammonia Emissions from in-Use Vehicles and the Implications for Fine Particle Control. Environ. Sci. Technol. 1998, 32 (8), 1053–1057. Sun, K.; Tao, L.; Miller, D. J.; Khan, M. A.; Zondlo, M. A. On-Road Ammonia Emissions Characterized by Mobile, Open-Path Measurements. Environ. Sci. Technol. 2014, 48 (7), 3943– 3950. Kean, A. J.; Harley, R. A.; Littlejohn, D.; Kendall, G. R. On-Road Measurement of Ammonia and Other Motor Vehicle Exhaust Emissions. Environ. Sci. Technol. 2000, 34 (17), 3535–3539.
19 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468
(6) (7) (8) (9)
(10) (11) (12)
(13)
(14)
(15) (16)
(17) (18)
(19) (20) (21)
(22) (23) (24) (25) (26)
Page 20 of 27
Kean, A. J.; Littlejohn, D.; Ban-Weiss, G. A.; Harley, R. A.; Kirchstetter, T. W.; Lunden, M. M. Trends in on-Road Vehicle Emissions of Ammonia. Atmos. Environ. 2009, 43 (8), 1565–1570. Healy, T. V.; McKay, H. A. C.; Pilbeam, A.; Scargill, D. Ammonia and Ammonium Sulfate in the Troposphere over the United Kingdom. J. Geophys. Res. 1970, 75 (12), 2317–2321. Lee, D. S.; Dollard, G. J. Uncertainties in Current Estimates of Emissions of Ammonia in the United Kingdom. Environ. Pollut. 1994, 86 (3), 267–277. Bouwman, A. F.; Lee, D. S.; Asman, W. A. H.; Dentener, F. J.; Van Der Hoek, K. W.; Olivier, J. G. J. A Global High-Resolution Emission Inventory for Ammonia. Glob. Biogeochem. Cycles 1997, 11 (4), 561–587. Sutton, M. A.; Dragosits, U.; Tang, Y. S.; Fowler, D. Ammonia Emissions from Non-Agricultural Sources in the UK. Atmos. Environ. 2000, 34 (6), 855–869. Battye, W.; Aneja, V. P.; Roelle, P. A. Evaluation and Improvement of Ammonia Emissions Inventories. Atmos. Environ. 2003, 37 (27), 3873–3883. Walker, J. T.; Whitall, D. R.; Robarge, W.; Paerl, H. W. Ambient Ammonia and Ammonium Aerosol across a Region of Variable Ammonia Emission Density. Atmos. Environ. 2004, 38 (9), 1235–1246. Saylor, R. D.; Edgerton, E. S.; Hartsell, B. E.; Baumann, K.; Hansen, D. A. Continuous Gaseous and Total Ammonia Measurements from the Southeastern Aerosol Research and Characterization (SEARCH) Study. Atmos. Environ. 2010, 44 (38), 4994–5004. Whitehead, J. D.; Longley, I. D.; Gallagher, M. W. Seasonal and Diurnal Variation in Atmospheric Ammonia in an Urban Environment Measured Using a Quantum Cascade Laser Absorption Spectrometer. Water. Air. Soil Pollut. 2007, 183 (1–4), 317–329. Brenninkmeijer, C. A. M. Applications of Stable Isotope Analysis to Atmospheric Trace Gas Budgets. In EPJ Web of Conferences; EDP Sciences, 2009; Vol. 1, pp 137–148. Brenninkmeijer, C. A. M.; Janssen, C.; Kaiser, J.; Röckmann, T.; Rhee, T. S.; Assonov, S. S. Isotope Effects in the Chemistry of Atmospheric Trace Compounds. Chem. Rev. 2003, 103 (12), 5125–5162. Whiticar, M. J. Carbon and Hydrogen Isotope Systematics of Bacterial Formation and Oxidation of Methane. Chem. Geol. 1999, 161 (1), 291–314. Stevens, C. M.; Engelkemeir, A. Stable Carbon Isotopic Composition of Methane from Some Natural and Anthropogenic Sources. J. Geophys. Res. Atmospheres 1984–2012 1988, 93 (D1), 725–733. Keeling, C. D. The Concentration and Isotopic Abundances of Carbon Dioxide in the Atmosphere. Tellus 1960, 12 (2), 200–203. Keeling, C. D.; Whorf, T. P.; Wahlen, M.; Plicht, J. van der. Interannual Extremes in the Rate of Rise of Atmospheric Carbon Dioxide since 1980. Nature 1995, 375 (6533), 666–670. Brenninkmeijer, C. A. M.; Röckmann, T.; Bräunlich, M.; Jöckel, P.; Bergamaschi, P. Review of Progress in Isotope Studies of Atmospheric Carbon Monoxide. Chemosphere - Glob. Change Sci. 1999, 1 (1–3), 33–52. Stevens, C. M.; Krout, L.; Walling, D.; Venters, A.; Engelkemeir, A.; Ross, L. E. The Isotopic Composition of Atmospheric Carbon Monoxide. Earth Planet. Sci. Lett. 1972, 16 (2), 147–165. Kim, K.-R.; Craig, H. Nitrogen-15 and Oxygen-18 Characteristics of Nitrous Oxide: A Global Perspective. Science 1993, 262 (5141), 1855–1857. Rahn, T.; Wahlen, M. Stable Isotope Enrichment in Stratospheric Nitrous Oxide. Science 1997, 278 (5344), 1776–1778. Freyer, H. D. Seasonal Trends of NH4+ and NO3- Nitrogen Isotope Composition in Rain Collected at Jülich, Germany. Tellus 1978, 30 (1), 83–92. Heaton, T. H. E. 15N14N Ratios of Nitrate and Ammonium in Rain at Pretoria, South Africa. Atmospheric Environ. 1967 1987, 21 (4), 843–852.
20 DRAFT
ACS Paragon Plus Environment
Page 21 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518
Analytical Chemistry
(27)
(28)
(29)
(30)
(31)
(32)
(33) (34)
(35)
(36)
(37) (38)
(39) (40) (41) (42)
(43)
(44)
Hristov, A. N.; Zaman, S.; Vander Pol, M.; Ndegwa, P.; Campbell, L.; Silva, S. Nitrogen Losses from Dairy Manure Estimated through Nitrogen Mass Balance and Chemical Markers. J. Environ. Qual. 2009, 38 (6), 2438–2448. Felix, J.D.; Elliott, E. M.; Gish, T. J.; McConnell, L. L.; Shaw, S. L. Characterizing the Isotopic Composition of Atmospheric Ammonia Emission Sources Using Passive Samplers and a Combined Oxidation-Bacterial Denitrifier Approach. Rapid Commun. Mass Spectrom. 2013, 27 (20), 2239–2246. Savard, M. M.; Cole, A.; Smirnoff, A.; Vet, R. δ15N Values of Atmospheric N Species Simultaneously Collected Using Sector-Based Samplers Distant from Sources – Isotopic Inheritance and Fractionation. Atmos. Environ. 2017, 162, 11–22. Smirnoff, A.; Savard, M. M.; Vet, R.; Simard, M.-C. Nitrogen and Triple Oxygen Isotopes in nearRoad Air Samples Using Chemical Conversion and Thermal Decomposition. Rapid Commun. Mass Spectrom. 2012, 26 (23), 2791–2804. Chang, Y.; Liu, X.; Deng, C.; Dore, A. J.; Zhuang, G. Source Apportionment of Atmospheric Ammonia Before, During, and after the 2014 APEC Summit in Beijing Using Stable Nitrogen Isotope Signatures. Atmospheric Chem. Phys. 2016, 16 (18), 11635–11647. Skinner, R. A.; Ineson, P.; Jones, H.; Sleep, D.; Rank, R. Using δ15N Values to Characterise the Nitrogen Nutrient Pathways from Intensive Animal Units. Rapid Commun. Mass Spectrom. 2006, 20 (19), 2858–2864. Schulz, H.; Gehre, M.; Hofmann, D.; Jung, K. Nitrogen Isotope Ratios in Pine Bark as an Indicator of N Emissions from Anthropogenic Sources. Environ. Monit. Assess. 2001, 69 (3), 283–297. Felix, J. D.; Elliott, E. M.; Gish, T.; Maghirang, R.; Cambal, L.; Clougherty, J. Examining the Transport of Ammonia Emissions across Landscapes Using Nitrogen Isotope Ratios. Atmos. Environ. 2014, 95, 563–570. Stelson, A. W.; Friedlander, S. K.; Seinfeld, J. H. A Note on the Equilibrium Relationship between Ammonia and Nitric Acid and Particulate Ammonium Nitrate. Atmospheric Environ. 1967 1979, 13 (3), 369–371. Stelson, A. W.; Seinfeld, J. H. Relative Humidity and pH Dependence of the Vapor Pressure of Ammonium Nitrate-Nitric Acid Solutions at 25 C. Atmospheric Environ. 1967 1982, 16 (5), 993– 1000. Stelson, A. W.; Seinfeld, J. H. Relative Humidity and Temperature Dependence of the Ammonium Nitrate Dissociation Constant. Atmospheric Environ. 1967 1982, 16 (5), 983–992. Kim, Y. P.; Seinfeld, J. H.; Saxena, P. Atmospheric Gas-Aerosol Equilibrium II. Analysis of Common Approximations and Activity Coefficient Calculation Methods. Aerosol Sci. Technol. 1993, 19 (2), 182–198. Kim, Y. P.; Seinfeld, J. H.; Saxena, P. Atmospheric Gas-Aerosol Equilibrium I. Thermodynamic Model. Aerosol Sci. Technol. 1993, 19 (2), 157–181. Nenes, A.; Pandis, S. N.; Pilinis, C. ISORROPIA: A New Thermodynamic Equilibrium Model for Multiphase Multicomponent Inorganic Aerosols. Aquat. Geochem. 1998, 4 (1), 123–152. Urey, H. C. The Thermodynamic Properties of Isotopic Substances. J Chem Soc 1947, 7, 562–581. Pan, Y.; Tian, S.; Liu, D.; Fang, Y.; Zhu, X.; Zhang, Q.; Zheng, B.; Michalski, G.; Wang, Y. Fossil Fuel Combustion-Related Emissions Dominate Atmospheric Ammonia Sources during Severe Haze Episodes: Evidence from 15N-Stable Isotope in Size-Resolved Aerosol Ammonium. Environ. Sci. Technol. 2016, 50 (15), 8049–8056. Sutton, M. A.; Tang, Y. S.; Miners, B.; Fowler, D. A New Diffusion Denuder System for LongTerm, Regional Monitoring of Atmospheric Ammonia and Ammonium. Water Air Soil Pollut. Focus 2001, 1 (5), 145–156. Koutrakis, P.; Sioutas, C.; Ferguson, S. T.; Wolfson, J. M.; Mulik, J. D.; Burton, R. M. Development and Evaluation of a Glass Honeycomb Denuder/filter Pack System to Collect Atmospheric Gases and Particles. Environ. Sci. Technol. 1993, 27 (12), 2497–2501.
21 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569
(45)
(46)
(47)
(48)
(49)
(50) (51)
(52)
(53)
(54)
(55) (56) (57)
(58)
(59)
(60) (61)
(62) (63)
Page 22 of 27
Koutrakis, P.; Wolfson, J. M.; Spengler, J. D. An Improved Method for Measuring Aerosol Strong Acidity: Results from a Nine-Month Study in St Louis, Missouri and Kingston, Tennessee. Atmospheric Environ. 1967 1988, 22 (1), 157–162. Allegrini, I.; De Santis, F.; Di Palo, V.; Febo, A.; Perrino, C.; Possanzini, M.; Liberti, A. Annular Denuder Method for Sampling Reactive Gases and Aerosols in the Atmosphere. Sci. Total Environ. 1987, 67 (1), 1–16. Li, Y.; Schwandner, F. M.; Sewell, H. J.; Zivkovich, A.; Tigges, M.; Raja, S.; Holcomb, S.; Molenar, J. V.; Sherman, L.; Archuleta, C.; et al. Observations of Ammonia, Nitric Acid, and Fine Particles in a Rural Gas Production Region. Atmos. Environ. 2014, 83, 80–89. Day, D. E.; Chen, X.; Gebhart, K. A.; Carrico, C. M.; Schwandner, F. M.; Benedict, K. B.; Schichtel, B. A.; Collett, J. L. Spatial and Temporal Variability of Ammonia and Other Inorganic Aerosol Species. Atmos. Environ. 2012, 61 (Supplement C), 490–498. Perrino, C.; De Santis, F.; Febo, A. Criteria for the Choice of a Denuder Sampling Technique Devoted to the Measurement of Atmospheric Nirous and Nitric Acids. Atmospheric Environ. Part Gen. Top. 1990, 24 (3), 617–626. Perrino, C.; Gherardi, M. Optimization of the Coating Layer for the Measurement of Ammonia by Diffusion Denuders. Atmos. Environ. 1999, 33 (28), 4579–4587. Hu, Q.; Zhang, L.; Evans, G. J.; Yao, X. Variability of Atmospheric Ammonia Related to Potential Emission Sources in Downtown Toronto, Canada. Atmos. Environ. 2014, 99 (Supplement C), 365– 373. Robarge, W. P.; Walker, J. T.; McCulloch, R. B.; Murray, G. Atmospheric Concentrations of Ammonia and Ammonium at an Agricultural Site in the Southeast United States. Atmos. Environ. 2002, 36 (10), 1661–1674. McCulloch, R. B.; Few, G. S.; Murray, G. C.; Aneja, V. P. Analysis of Ammonia, Ammonium Aerosols and Acid Gases in the Atmosphere at a Commercial Hog Farm in Eastern North Carolina, USA. Environ. Pollut. 1998, 102 (1), 263–268. Brauer, M.; Koutrakis, P.; Wolfson, J. M.; Spengler, J. D. Evaluation of the Gas Collection of an Annular Denuder System under Simulated Atmospheric Conditions. Atmospheric Environ. 1967 1989, 23 (9), 1981–1986. Vaittinen, O.; Metsälä, M.; Persijn, S.; Vainio, M.; Halonen, L. Adsorption of Ammonia on Treated Stainless Steel and Polymer Surfaces. Appl. Phys. B 2014, 115 (2), 185–196. Bolleter, W. T.; Bushman, C. J.; Tidwell, P. W. Spectrophotometric Determination of Ammonia as Indophenol. Anal. Chem. 1961, 33 (4), 592–594. Zhang, L.; Altabet, M. A.; Wu, T.; Hadas, O. Sensitive Measurement of NH4+ 15N/14N (δ15NH4+) at Natural Abundance Levels in Fresh and Saltwaters. Anal. Chem. 2007, 79 (14), 5297–5303. McIlvin, M. R.; Altabet, M. A. Chemical Conversion of Nitrate and Nitrite to Nitrous Oxide for Nitrogen and Oxygen Isotopic Analysis in Freshwater and Seawater. Anal. Chem. 2005, 77 (17), 5589–5595. Sigman, D. M.; Casciotti, K. L.; Andreani, M.; Barford, C.; Galanter, M.; Böhlke, J. K. A Bacterial Method for the Nitrogen Isotopic Analysis of Nitrate in Seawater and Freshwater. Anal. Chem. 2001, 73 (17), 4145–4153. Bohlke, J. k.; Gwinn, C. j.; Coplen, T. b. New Reference Materials for Nitrogen-Isotope-Ratio Measurements. Geostand. Newsl. 1993, 17 (1), 159–164. Böhlke, J. K.; Coplen, T. B. Reference and Intercomparison Materials for Stable Isotopes of Light Elements. In Proceedings of the IAEA-TECDOC-825 Consultants Meeting Held in Vienna, Vienna, Austria; 1993; Vol. 13. Böhlke, J. K.; Smith, R. L.; Hannon, J. E. Isotopic Analysis of N and O in Nitrite and Nitrate by Sequential Selective Bacterial Reduction to N2O. Anal. Chem. 2007, 79 (15), 5888–5895. Febo, A.; De Santis, F.; Perrino, C.; Giusto, M. Evaluation of Laboratory and Field Performance of Denuder Tubes: A Theoretical Approach. Atmospheric Environ. 1967 1989, 23 (7), 1517–1530. 22 DRAFT
ACS Paragon Plus Environment
Page 23 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
570
Analytical Chemistry
for TOC only:
571 572 573
23 DRAFT
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
84x75mm (300 x 300 DPI)
ACS Paragon Plus Environment
Page 24 of 27
Page 25 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
169x67mm (300 x 300 DPI)
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
84x71mm (300 x 300 DPI)
ACS Paragon Plus Environment
Page 26 of 27
Page 27 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
84x141mm (300 x 300 DPI)
ACS Paragon Plus Environment