Subscriber access provided by Yale University Library
Article
The combined effect of ultrasound and ozone on bacteria in water Amna Mohammed Al-hashimi, Timothy J. Mason, and Eadaoin Maria Joyce Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/es5045437 • Publication Date (Web): 16 May 2015 Downloaded from http://pubs.acs.org on May 18, 2015
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 25
1 2
Environmental Science & Technology
The combined effect of ultrasound and ozone on bacteria in water
3
Amna M. Al-Hashimi, Timothy J. Mason and Eadaoin M. Joyce*
4 5
The Sonochemistry Centre, Coventry University, Faculty of Health and Life Sciences, Priory Street, Coventry, UK
6 7
Tel: +44 2476888075; Fax: +44 2476 888173; *Corresponding author email:
[email protected] 8
Keyword: Ozone,ultrasound,water treatment, flow cytometry, Escherichia coli
9
*Corresponding author e-mail:
[email protected] 10
Abstract ........................................................................................................................................... 2
11
Introduction ..................................................................................................................................... 3
12
Material and methods ...................................................................................................................... 5
13
Preparation and viability assessment of bacterial suspensions ................................................... 5
14
Ultrasound and ozone system (USO3) ........................................................................................ 6
15
Transmission electron microscopy ............................................................................................. 7
16
Results ........................................................................................................................................... 10
17
Measurement of dissolved ozone in water ................................................................................ 10
18
Effect of ultrasound on the viability of Escherichia coliusing theUSO3 system. ..................... 11
19
Effect of ozone on 75L Escherichia coli treated with the USO3 system for 16 minutes ......... 13
20 21
Combined effect of ultrasound and ozone on the viability of Escherichia coli treated using the USO3 system ............................................................................................................................. 14
22
Discussion ..................................................................................................................................... 16
23
Acknowledgment .......................................................................................................................... 21
24
References ..................................................................................................................................... 21
25 26
ACS Paragon Plus Environment
1
Environmental Science & Technology
Page 2 of 25
27 28
Abstract
29
the biological disinfection of water on a large-scale application using viable plate counts and
30
flow cytometry.
31
Methods and results: Escherichia coli B bacteria in saline suspension was treated using a
32
commercially available combined ultrasound and ozone system (USO3 - USS, Ultrasonic
33
Systems Gmbh, Germany) for 16 minutes. Two analytical methods were used to assess the
34
results in terms of live and dead cells in the bulk liquid: standard viable plate counting recorded
35
in terms of Colony Forming Units (CFU) per ml and flow cytometry (FCM). In the latter case 1
36
ml bacterial suspension was stained simultaneously with the fluorescent stains SYTO9 and
37
Propidium Iodide (PI). Transmission electron microscopy was used to generate images
38
identifying the biological effects of different treatments using ultrasound and ozone on bacterial
39
cell walls. Results demonstrated that treatment with ozone alone (1mg/l) resulted in a significant
40
reduction (93%) in the number of live cells after 16 minutes treatment whereas ultrasound alone
41
showed only a small reduction (24%). However a combination of ozone and ultrasound showed a
42
synergistic effect and enhanced the inactivation to 99%after 4 minutes.
43
Conclusion: A combined ultrasound and ozone treatment of bacterial suspensions using a
44
commercial system (USS, Ultrasonic Systems Gmbh) affords a promising method for water
45
disinfection that is better than treatment using either method alone. Standard viable plate count
46
analysis is normally used to assess the effectiveness of disinfection treatments; however flow
47
cytometry proved to be a more sensitive method to determine the actual effects in terms of not
48
only live and dead cells but also damaged cells. This type of analysis (cell damage) is difficult if
49
not impossible to achieve using traditional plate counting methodology.
Aim of the study: To assess the synergetic effect of combined ultrasound and ozone treatment on
ACS Paragon Plus Environment
2
Page 3 of 25
Environmental Science & Technology
50 51
Introduction
52
replacement for chlorination in that it reduces disinfection by-products [1]. It is an unstable tri-
53
oxygen molecule which easily releases oxygen atoms in aqueous solutions which subsequently
54
reacts with hydrogen ions in water leading to increased levels of hydroxyl radicals (OH●) in the
55
medium [2]. Joret showed that ozone had lethal effects on a wide range of microbes, such as
56
bacteria, viruses, parasites, Candida, polio virus and Mycobacterium through oxidizing the cell
57
membrane resulting in cell disruption [3]. Disinfection by ozone is strongly dependent on water
58
characteristics such as dissolved organic carbon (DOC), pH, temperature and bromide
59
concentrations [4][5].
Ozone is an important disinfection gas for drinking water treatment and is a suitable
60
Over the last 20 years researchers and engineers have found that a combination of two or more
61
disinfection methods involving oxidation (Advanced Oxidation Processes - AOPs) is very
62
effective in water purification. AOPs help to improve water quality and reduce treatment costs
63
[6]. Combinations of ultrasound with other oxidants such as ozone, chlorine and hydrogen
64
peroxide (H2O2) have been investigated [4]. These studies concluded that employing a
65
combination of ozone and ultrasound treatments in the secondary stage of wastewater treatment
66
resulted in reductions in the required contact time to inactivate microorganisms.
67
The collapse of acoustic cavitation bubbles generated during the application of ultrasound to
68
aqueous systems affords several routes to disinfection [7][8]. Cavitation bubble collapse creates
69
a “hot spot” where extremely high temperatures, pressures and free radicals form [9]. The
70
possible effects of sonication on microorganisms are:
71 72 73
High temperatures in and around the collapsing bubble resulting in enzyme denaturation
ACS Paragon Plus Environment
3
Environmental Science & Technology
74
75 76 77
Page 4 of 25
High hydro-mechanical pressures generated on bubble collapse resulting in shear forces and liquid jets which lyse cells
Production of a highly oxidative species of OH● and H2O2from the hot spots which can attack and weaken cell membranes by attacking their chemical structure [10] [11].
78
The impact of ultrasound on bacteria has been reported in previous studies that focus on cell
79
inactivation, the release of cell contents and the production of a temporary permeability of cell
80
walls. In addition, the effect of ultrasound on inactivation of microorganisms using varying
81
treatment times for many pure cultures of different bacteria, yeast, fungi and viruses has been
82
reported [12][13].
83
Microorganism inactivation has also been investigated using a combination of ultrasound with
84
ozone or UV radiation [14][15][16][17], high pressures and temperatures, or different ultrasonic
85
parameters [18][19].
86
Previous investigations of combined treatments with ozone and ultrasound have indicated that
87
the synergistic effect of sonication and ozone significantly increases bacterial inactivation rates.
88
Jyoti and Pandit indicated that microbial damage resulting from hydro-mechanical forces is
89
greater than sonochemical effects [20]. It was reported that the combination of hydrodynamic
90
acoustic cavitation and ozone reduced power consumption, in addition to reducing the formation
91
of disinfection by-products (DBP) during treatment [21].
92 93
Jyoti and Pandit used the viable plate count (VPC) analysis method to assess the effect of
94
acoustic cavitation and ozone on microbial disruption [22]. However, culture based methods are
95
time consuming and do not identify sub-lethally damaged cells. Such cells retain some metabolic
96
activity but are unable to produce a viable colony on solid growth media (agar). This can occur
ACS Paragon Plus Environment
4
Page 5 of 25
Environmental Science & Technology
97
when bacteria undergo stress but are not completely inactivated or killed by water treatment
98
methods such as chlorination. However, if sufficient numbers of these organisms are ingested
99
they have the potential to cause illness [23]. Therefore, there is an increasing interest in finding
100
an analytical technique which can yield more information on the physiological status of bacteria
101
than can be deduced from standard culture methods. Additionally, different environmental
102
conditions can affect the viable counting method [24]. Various characteristics must be
103
considered when evaluating microbial viability which includes membrane integrity, cell growth
104
and metabolic activity; however membrane integrity has received the majority of research [25].
105
Flow cytometry (FCM) is capable of quantifying features of cells primarily by visual means.
106
FCM records measurements from individual cells but can process thousands of cells (10,000
107
events) in seconds. In conjunction with fluorescent staining it can provide information relating to
108
the estimation and discrimination of different physiological characteristics of cells [24].The aim
109
of this study was to evaluate the application of FCM with dual staining for a rapid, accurate and
110
reliable assessment of cell viability after ultrasound, ozone and combined treatments using the
111
USS system. The results were compared with those obtained using a traditional CFU culture
112
method.
113 114
Material and methods Preparation and viability assessment of bacterial suspensions
115
A stock suspension of Escherichia coli was prepared according to [26]. 1 ml of bacterial
116
suspension was taken after 0, 2, 4, 8 and 16 minutes treatment and added to 9 ml of 0.9% saline
117
(9 g/L sigma Aldrich Ltd.) containing sodium thiosulfate Na2S2O3 (2 g/l) to neutralise any
118
residual ozone in the sample. Samples were serially diluted to obtain 2g/l [14]. Each dilution was
ACS Paragon Plus Environment
5
Environmental Science & Technology
Page 6 of 25
119
cultured on nutrient agar plates in triplicates and incubated at 37°C for 24 hours. The results
120
from plate counts were converted into CFU/ml:
121 122
CFU’s/ml = No. of colonies * volume of cultured sample * dilution of sample
123 124
Ultrasound and ozone system (USO 3 )
125
A large-scale water treatment device from Ultrasonic Systems Gmbh, Germany, was employed
126
to deliver ultrasound and ozone for water treatment using a technology known as USO3. The
127
system consisted of an ozone generator, 20 ultrasonic transducers at maximum power setting
128
(100 Watt each/612 kHz), a mixer and external pump that was capable of treating up to a
129
maximum capacity of 4 m3/h = 66.67 L/min. Internally, the system consisted of long steel tubes
130
with a diameter of 108.3 mm, L = 3.02 m, V = 28 L = 0.028 m3), retention time: 0.8 min. The
131
bacterial suspension was pumped into the USO3 kit using an external pump (flow rate 35 L/min).
132
Experiments were performed at a constant flow rate of 35 L/min, delivering a constant ozone
133
supply capable of generating a concentration which accumulated to 1 mg/L. The aqueous
134
suspension of the bacteria was treated at this flow rate in a recycling system for 16 minutes with
135
pulsed ultrasonic treatment on for 5 seconds and off for 5 seconds. The ozone concentration was
136
measured using the indigo colorimetric method [27].
137 138
Transmission electron microscopy
139
A transmission electron microscope TEM was used to provide high resolution images, (2010F,
140
JEOL Ltd., Japan). The instrument used a 200kV field emission gun instrument in cryo-
141
conditions and was fitted with a GatanUltraScan™ 4000 camera which provided the spatial
ACS Paragon Plus Environment
6
Page 7 of 25
Environmental Science & Technology
142
resolution necessary for detailed biological structural analysis and very high magnification of
143
samples down to 0.5nm with three dimensional imaging.
144 145
Experiment design
146
75 L of Escherichia coli bacterial suspension (OD 0.01, 2x105 cell/ml) was treated with
147
ultrasound alone, ozone alone (1mg/l, power 160 W, 10% gas flow) and a combination of
148
ultrasound and ozone for 16 minutes. Samples were taken after 0, 2, 4, 8 and 16 minutes
149
treatment and the residual ozone in sample was neutralised using 2% sodium thiosulfate (Sigma
150
Aldrich Ltd.) in sterile saline (0.9% NaCl Sigma Aldrich Ltd.). An in-built cooling system was
151
used to maintain sample temperature below 25ºC. Samples were analysed by viable plate counts
152
to measure CFU/ml and flow cytometry. All data was analysed using ANOVA test.
153 154
Bacterial staining and flow cytometry
155
The use of double staining techniques involving nucleic acid stains (SYTO9) (green
156
fluorescence) and Propidium Iodide (PI) (red fluorescence) provide a valuable method for the
157
estimation of bacteria viability [185]. The fluorescent probes/stains and counting kit for flow
158
cytometry were purchased from Invitrogen (LIVE/DEAD® BaclightTM bacterial viability and
159
counting kit) which consisted of two stains SYTO9 (nucleic acid stain) at a dose of 200 µl (3.34
160
mM in DMSO) specific for live cells, Propidium Iodide (PI) at a dose of 200 µl (20 mM in
161
DMSO) for dead cells. The calibration beads were microsphere standard beads 6.0 µm diameter
162
with a concentration of 1×108 beads/ml in deionised water (10ml) containing 2 mM sodium
163
azide.
164 165
Flow cytometry measures several parameters at the same time for each cell:
ACS Paragon Plus Environment
7
Environmental Science & Technology
Page 8 of 25
166
Low angle forward scatter intensity (FSC) is proportional to cell diameter.
167
Orthogonal (90º) scatter intensity (SSC) relates to the quantity of granular structures within the
168
cell. Fluorescence intensities at several wavelengths can be observed using different fluorescence
169
channels.
170
Estimation of cell integrity or viability using flow cytometry
171
500 µl bacterial suspensions were collected in an Eppendorf tube (1.5 ml). Samples were
172
simultaneously stained with SYTO9 and Propidium Iodide (PI). Fluorochromes were added
173
according to the manufacturer’s instructions. Dyes were purchased as a BaclightTM bacterial
174
viability and counting kit from Invitrogen Ltd. 1.5 µl of fluorescent stain was added to each
175
sample, vortexed and analysed after 10-30 minutes incubation at room temperature. Excitation of
176
SYTO9 emitted green fluorescence at 525-550 nm and excitation of PI at 536nm produced red
177
fluorescence at 600nm. Viable cells (with intact membranes) are only permeable to SYTO9 but
178
not PI; hence viable cells emit green fluorescence. In contrast, dead cells (with permeabilised
179
membranes) were stained with PI and emit red fluorescence. BD FACS Calibur flow cytometry
180
was optimised by FACS COMP standard fluorescence beads (2 µm) to verify the instrument
181
performance. Bacterial populations were positioned so that they were all located in scale on a
182
FSC V’s SSC plot. For fluorescence measurements, FL1, FL2 and FL3 voltages were adjusted to
183
place the unstained populations in the lower left quadrant of two parameter plots. Flow
184
cytometry instruments settings were as follows: threshold (FSC), FSC (E02), PMT 4.75
185
(logarithmic amplification (LA), SSC-597 V (LA), FL1 617/550 V (LA), FL2 531 V (LA) and
186
FL3 623 V (LA). 10,000 cells were acquired per acquisition and bacterial populations were gated
187
using a combination of FSC, SSC, live/dead cells and discriminated using FL1 V’s FL3. Live (3
188
hour bacterial culture) and dead (heating bacterial cells to 75°C for 30 minutes) controls were
ACS Paragon Plus Environment
8
Page 9 of 25
Environmental Science & Technology
189
also undertaken to calibrate results. To ensure continuity of results all experiments were run for a
190
total of 16 minutes.
191 192 193
Effect of ultrasound and ozone separately a nd in combination on the biological structure of bacterial cell walls using CRYO TEM analysis
194
Escherichia coli bacterial suspension was placed in a suitable container and treated with
195
ultrasound alone ozone alone and a combination of ultrasound and ozone for 16 minutes using
196
the USO3 system. Samples were taken at 0, 2, 4, 8 and 16 minutes and analysed using TEM
197
microscopy. To determine the percentage inactivation by TEM, a protocol was followed where
198
intact cells were considered to be robust and cells displaying a loss of cell integrity were
199
considered dead. For each TEM calculation 100 cells within a grid were observed following each
200
treatment. Cells which appear to show damage were then converted to a percentage.
201 202
Supporting Information
203
Figure 1 Schematic diagram of the USO3 system taken from the manual provided by USS, (20
204
ultrasonic transducers at maximum power setting (100 Watt each/612 kHz)
Output
Input
205 Ultrasonic transducer
Opti-mixer
ACS Paragon Plus Environment
9
Environmental Science & Technology
Page 10 of 25
206 207 208
Measurement of dissolved ozone in water
209
NaCl (0.9 g/l) was added to 75 L of fresh water to convert the water to saline which was
210
circulated through the ultrasound and ozone (USO3) system for 16 minutes. 50ml of sample was
211
collected and analysed using the UV-Vis spectrophotometer (Shimadzu, UK 5030). Results
212
illustrate that the absorbance of water samples at 254 nm increased over 16 minutes treatment,
213
which is due to the accumulation of ozone in water over 16 minutes treatment (Figure 2).
214 215
Figure 2 Accumulation of residual ozone in 75 L water using the ultrasound and ozone system
216
over 16 minutes analysed using UV-Vis spectrophotometry
Control
Ozone (ppm)
Abs.
Time [min]
217 218 219
Results
220
Effect of ultrasound on the viability of Escherichia coliusing theUSO 3 system.
221
A single bacterial suspension of Escherichia coli was treated with ultrasound for 16 minutes.
222
Results illustrate a small inactivation effect of 24% on the number of live cells over 16 minutes
223
treatment compared to controls (Figure 3). This is in accord with other results obtained at a
ACS Paragon Plus Environment
10
Page 11 of 25
Environmental Science & Technology
224
laboratory scale using higher frequencies [26] [28]. 512 kHz was used to treat different types of
225
bacteria for 15 and 60 minutes which achieved less than 1 log reduction at the end of the
226
treatment time.
227 228
Figure 3 Effect of ultrasound on the viability of Escherichia coli, (OD 0.01, 2x105 cell/ml) using
229
the USO3 system for 16 minutes analysed using viable plate counts Control
CFU/ml
US
230 231
Time [min]
232
The bacteria were also analysed by flow cytometry using the Invitrogen BaclightTM bacterial
233
viability and counting kit. The dot plots illustrated in Figure 4 represent bacterial populations
234
that are divided into two populations; live cells appearing in the lower right (LR) quadrant and
235
dead cells in the lower left (LL) quadrant. Flow cytometry data illustrates small reductions of
236
26% in the number of live cells after 16 minutes treatment. Flow cytometry data supports viable
237
plate count results, but some cells were observed in the live cells position after treatment.
238
Although there were still some cells observed in the position expected for live cells the majority
239
of cellular material after treatment appeared in an intermediate position between that for live
ACS Paragon Plus Environment
11
Environmental Science & Technology
Page 12 of 25
240
cells and that for dead cells. This is where one would normally find viable but non culturable
241
(VBNC) cells. Cell wall fragments may up take some of the background fluorescent stain.
242 243 244
Figure 4 Effect of ultrasound on the viability of Escherichia coli treated with the USO3 system
245
for 16 minutes analysed using flow cytometry
246 247
Control
16 min
248 249 250
ACS Paragon Plus Environment
12
Page 13 of 25
Environmental Science & Technology
251 252
Effect of ozone on 75L Escherichia coli treated with theUSO 3 system for 16 minutes
253
A single bacterial suspension of Escherichia coli was treated with ozone using the USO3
254
system for 16 minutes. Results demonstrate a 93% reduction in number of live E. coli cells over
255
16 minutes treatment time (Figure 5). The results obtained for reductions in E. coli are in accord
256
with those of other researchers who achieved 1 log reduction for E. coli [30].
257 258
Figure 5 Effect of ozone on Escherichia coli using the USO3 system for 16 minutes analysed
259
using viable plate counts
Control
CFU/ml
O3
Time [min]
260 261 262
Escherichia coli were also analysed using flow cytometry as outlined above. The data illustrates
263
a significant reduction of 85% (ANOVA P value 0.01) in the number of live cells within 16
264
minutes of treatment. However, some cells still remained in the lower right (LR) quadrant of the
265
graph after treatment. The appearance of live bacterial cells is due to fragments or parts of cell
266
walls that can uptake fluorescent stains specific for live cells (SYTO9) and so appear in live cell
267
position.
ACS Paragon Plus Environment
13
Environmental Science & Technology
Page 14 of 25
268
Figure 6 Effect of ozone on Escherichia coli treated with the USO3 system for 16 minutes
269
analysed using flow cytometry
270
Control
16 min
271 272 273 274
Combined effect of ultrasound and ozone on the viability of Escherichia coli treated using the USO 3 system
275
A single bacterial suspension of Escherichia coli was simultaneously treated with ultrasound and
276
ozone for 16 minutes. Results illustrate a significant inactivation effect of 99% occurred after 4
277
minutes treatment (Figure 7).
ACS Paragon Plus Environment
14
Page 15 of 25
Environmental Science & Technology
278
Figure 7 Effect of ultrasound and ozone on the viability of Escherichia coli using the USO3
279
system for 16 minutes analysed using viable plate counts Control
CFU/ml
USO3
Time [min]
280 281 282 283 284
Complete inactivation was achieved within 4 minutes, which can be ascribed to a synergistic effect of ultrasound and ozone.
285
Flow cytometry data showed a significant reduction of 99% (ANOVA P value 0.01) in the
286
number of live cells along with an increase in number of dead cells over 16 minutes treatment
287
with ultrasound and ozone (Figure 8). However, a small number of cells (0.6%) appeared to
288
remain in the lower right quadrant following treatment.
289 290
Figure 8 Effect of ultrasound and ozone on the viability of Escherichia coli using the USO3
291
system for 16 minutes analysed using FCM
292 293
Control
16 min
ACS Paragon Plus Environment
15
Environmental Science & Technology
Page 16 of 25
294 295 296 297
Discussion Effect of ultrasound alone on Escherichia coli treated with the USO3 system for 16 minutes
298
Bacterial cells treated with ultrasound alone using the USO3 system demonstrated a small
299
inactivation effect 24% according to VPC and 26% according to FCM (ANOVA P value 0.05)
300
after 16 minutes treatment. This is in accord with previous findings at 512 kHz in that higher
301
frequencies at low power have low inactivation effects [26].FCM illustrated a good correlation
302
with VPC results supporting this evidence of poor inactivation rates [30] [32].
303 304
Effect of ozone alone on Escherichia coli treated with the USO3system for 16 minutes
305
Ozone treatment clearly demonstrated a significant reduction (93% according to VPC and 85%
306
according to FCM) (ANOVA P value 0.01) in bacterial cells following 16 minutes treatment.
307
Flow cytometry data showed a significant reduction in the number of live cells along with
308
increases in the number of dead cells. A study by Sharma reported a promising technique to
309
oxidize bacteria in the food and water industry, resulting in more than a 3.5 log reduction in
310
viable cells after treatment with 1 ppm ozone for 60 minutes using a selection of bacterial strains
311
including the spore forming bacteria Bacillus subtilis [31].
312
ACS Paragon Plus Environment
16
Page 17 of 25
313 314 315 316
Environmental Science & Technology
Effect of combined treatment ultrasound and ozone on Escherichia coli treated with the USO3system for 16 minutes Ultrasound can enhance the effect of ozone on bacteria through a number of processes:
317 318
De-clumping of bacterial clusters to disperse bacteria as single cells which are more susceptible to oxidation by ozone
319
Formation and collapse of cavitation bubbles leads to weakening of the bacterial cells due to breaking chemical bonds in the cell membrane
320
Sonication enhances ozone decomposition rates in water during treatment
321
Sonication increases the level of free radicals and hydrogen peroxide (H2O2) in the
322
medium which has bactericidal effects on various microorganisms [25]. Combined
323
treatment using the USO3 system produced complete inactivation (99% according to
324
VPC and 99% according to FCM) in bacterial cells within 4 minutes treatment.
325
Ultrasound clearly enhanced the effect of ozone on bacterial inactivation (ANOVA P
326
value 0.01).
327
It is clear that the application of (USO3) could significantly contribute in water treatment
328
plants. The combination of ozone and ultrasound provides synergetic effects which can
329
substantially reduce the cost of treatment and improves health and safety issues associated with
330
ozone production. In addition, by employing combined techniques (USO3) can rapidly achieve a
331
reliable and safe quality of water for consumers.
332
(TEM) evidence of the effect of ultrasound alone for 16 minutes on the biological structure of
333
Escherichia coli treated with the USO3system
334
TEM imaging was used to show any structural changes on the cells when a Escherichia coli
335
bacterial suspension was treated with ultrasound alone. Results showed cell shrinkage and cracks
ACS Paragon Plus Environment
17
Environmental Science & Technology
Page 18 of 25
336
in some cell walls and in some cases destruction of the entire cell. Overall approximately 24% of
337
bacterial cells had an irregular shape after treatment. An example of a normal and damaged cell
338
is shown in (Figure 9).
339 340
Figure 9 (TEM) images showing the effect of ultrasound on the biological structure of
341
Escherichia coli treated with the USO3 system (A) control (untreated 24 hour culture, bacterial
342
cell with intact cell wall) (B) 16 minutes ultrasound treatment (bacterial cell wall with irregular
343
surface and holes due to sonication treatment)
344 345
(A) Control
(B) 16 min treatment
346 347 348 349 350
(TEM) evidence of the effect of ozone alone (1mg/L) on the biological structure of Escherichia coli treated with the USO3 system
351
Escherichia coli bacterial suspension was treated with ozone alone to determine the effect of
352
ozone on the biological structure of bacterial cells. Results show that ozone produces holes in the
353
cell walls as a result of oxidation effects. Overall approximately 86% of bacterial cells had such
354
holes in their cell wall and some of the cells had lost their entire cell wall after treatment (Figure
355
10).These results are in accord with those of Sharma who demonstrated bactericidal effects of
ACS Paragon Plus Environment
18
Page 19 of 25
Environmental Science & Technology
356
ozone result from the disruption of envelope integrity through peroxidation of phospholipids and
357
lipoproteins [31].Overall approximately 86% of bacterial cells lost their cell wall after treatment
358
(Figure 10).
359 360
Figure 10 (TEM) images showing the effect of ozone alone on the biological structure of
361
Escherichia coli treated with the USO3 system (A) control (B) 16 minutes ozone treatment
362
(A) Control
(B) 16 min treatment
363 364 365
Transmission Electron Microscopy (TEM) evidence of the effect of combined treatments of
366
ultrasound and ozone on the biological structure of Escherichia coli treated with the USO3
367
system. Escherichia coli were subjected to combined treatment with ultrasound and ozone for 16
368
minutes using the USO3system. Results illustrate that combined treatment with ultrasound and
369
ozone had a significantly greater inactivation effect than separate treatment. TEM images show
370
that 95% of the bacteria lost the entire cell walls after treatment, which may be due to the
371
synergistic effect of ultrasound and ozone over 16 minutes treatment (Figure 11).
372 373
ACS Paragon Plus Environment
19
Environmental Science & Technology
Page 20 of 25
374
Figure 11 (TEM) images showing the effect of ultrasound and ozone on the biological structure
375
of Escherichia coli treated with the USO3 system (A) control (B) 16 minutes treatment with
376
ultrasound and ozone
377 378
(A) Control
(B) 16 min treatment
379 380 381 382
From the above TEM images it is clear that ultrasound combined with ozone had a great
383
impact on the biological structure of Escherichia coli bacteria. Ozone alone has a significant
384
effect on the bacterial cells but ultrasound enhanced this effect resulting in cell shrinkage due to
385
cell wall removal and the subsequent release of cell contents. This may be due to the combined
386
ultrasonic effects (hydro-mechanical pressures resulting in shear forces and liquid jets which lyse
387
cells, high temperatures and chemical effects due to the production of highly oxidative species of
388
OH● and H2O2), which have a strong anti-microbial action on cells [26].Summary of the (TEM)
389
results for bacterial inactivation. The percentage inactivation by TEM was determined using the
390
protocol outlined in the material and methods section and the results are shown (Table 1).
391 392
ACS Paragon Plus Environment
20
Page 21 of 25
Environmental Science & Technology
393
Table 1 Percentage inactivation in E. coli bacteria 1011 cell/ml treated using the USO3 system for
394
16 minutes analysed by TEM
395 Bacterial Ultrasound Strain (612 kHz) E. coli E. coli YES E. coli YES
Ozone (0.5 mg/l) YES YES
Treatment time(min) 16 16 16
% inactivation 86 24 95
396 397 398
Acknowledgment
399
The authors would like to thank the Iraqi Ministry of Higher Education who supported this
400
research, Dr. Afthab Hussain at Coventry University for assistance with flow cytometry and Mr.
401
Ian Portman director of the imaging suite at Warwick University for support in TEM data
402
analysis.
403 404
References 1. Von Gunten, U. ‘Ozonation of Drinking Water: Part II. ‘Disinfection and by-Product
405
Formation in Presence of Bromide, Iodide or Chlorine'. Water Research. 2009, 37 (7), 1469-
406
1487
407
2. Pascual, A.;Liorca I.;Canut, A. ‘Use of Ozone in Food Industries for Reducing the
408
Environmental Impact of Cleaning and Disinfection Activities'. Food Sciences and Technology.
409
2009, 18, S29-S35.
410
3. Joret, J.; Mennecart, V.; Robert, C.; Compagnon, B.; Cervantes, P. ‘Inactivation of
411
Indigenous Bacteria in Water by Ozone and Chlorine'. Water Science and Technology. 1975, 35
412
(11-12), 81-86.
ACS Paragon Plus Environment
21
Environmental Science & Technology
413 414 415 416
Page 22 of 25
4. Burleson, G.; Murray, T.; Pollard, M. ‘Inactivation of Viruses and Bacteria by Ozone, with and without Sonication'. Journal of Applied Microbiology’. 1975, 29 (3), 340-344. 5. Hunt, N.; Mariñas, B. ‘Kinetics of Escherichia coli Inactivation with Ozone'. Water Research. 1997, 31 (6), 1355-1362.
417
6. Mezule, L.; Tsyfansky, S.; Yakushevich, V.; Juhna, T. ‘A Simple Technique for Water
418
Disinfection with Hydrodynamic Cavitation: Effect on Survival of Escherichia coli'.
419
Desalination. 2009, 248 (1-3), 152-159.
420
7. Joyce, E.M.; Mason, T.M. ‘Sonication used as a biocide, A review: Ultrasound a greener
421
alternative to chemical biocides?’, Chemistry Today, 2008, 26(6).
422 423 424 425 426 427
8. Wu, X.; Joyce, E.M.; Mason, T.J. ‘The effects of ultrasound on cyanobacteria Harmful Algae’, 2011, 10 (6), 738-743, 9. Mason, T.; Joyce, E.; Phull, S.; Lorimer, J. ‘Potential Uses of Ultrasound in the Biological Decontamination of Water’. Ultrasonic Sonochemistry. 2003, 10 (6), 319-23. 10. Mason, T.; Lorimer, P.‘Applied Sonochemistry the Uses of Power Ultrasound in Chemistry and Processing’. Verlage GmbH -Weinheim: Wiley- VCH. 2001
428
11. Mason, T. Sonochemistry. 1st Ed. New York: Oxford University Primes.,1999.
429
12. Hua, J.;Thompson, J. ‘Inactivation of E. coli by Sonication at Discrete Ultrasonic
430 431 432
Frequencies’. Water Research. 2000, 34 (15), 3888-3893. 13. Mahvi, H.A. ‘Application of Ultrasonic Technology for Water and Wastewater Treatment’. Iranian Journal of Public Health. 2009, 38(12). 1-17.
ACS Paragon Plus Environment
22
Page 23 of 25
433
Environmental Science & Technology
14. Kruithof, J.; Kamp, P.; Martijn, B.;Belosevic, M.; Williams, G. Proceedings of the Third
434
International
435
http://iuva.org/sites/default/files/member/news/IUVA_news/Vol08/Issue2/MohseniArticle.pdf
436 437
Congress
on
Ultraviolet
Technologies:
Vancouver,
BC,
Canada.2005;
15. Blume, T.; Neis, U. ‘Improved Wastewater Disinfection by Ultrasonic Pre-Treatment’. UltrasonicsSonochemistry. 2004, 11 (5), 333-336.
438
16. Rashmi, C.; David, H.; Bremnera, C.; Namkungb, P.;Colliera, J.; Parag, R. ‘Water
439
Disinfection using the Novel Approach of Ozone and a Liquid Whistle Reactor’. Biochemical
440
Engineering Journal. 2007, 53 (3), 357-364.
441
17. Drakopoulou, S.; Terzakis, S.;Fountoulakis, M. S.; Mantzavinos, D.; Manios, T.
442
‘Ultrasound-Induced Inactivation of Gram-Negative and Gram-Positive Bacteria in Secondary
443
Treated Municipal Wastewater’. UltrasonicsSonochemistry. 2009, 16 (5), 629-634.
444 445
18. Berlan, J.; Mason, T. Advances in Sonochemistry.' 6th Ed. Horwood publishing limitted, West Sussex England, 1996.
446
19. Joyce, E.M.; Wu, X.; Mason, T.J. 'Effect of ultrasonic frequency and power on algae
447
suspensions'. Journal of Environmental Science and Health. A, Tox/Hazard Subst Environ Eng.
448
2010, 45 (7), 863-866.
449 450
20. Jyoti, K.; Pandit, A. ‘Effect of Cavitation on Chemical Disinfection Efficiency'. Water Research. 2004, 38 (9), 2249-2258.
451
21. Noci, F.; Walkling-Ribeiro, M.; Cronin, D.; Morgan, D.; Lyng, J. ‘Effect of
452
Thermosonication, Pulsed Electric Field and their Combination on Inactivation of
453
Listeriainnocua in Milk’. International Dairy Journal. 2009, 19 (1), 30-35.
ACS Paragon Plus Environment
23
Environmental Science & Technology
Page 24 of 25
454
22. Papadimitriou, K.; Pratsinis, H.; Nebe-von-Caron, G.; Kletsas, D.; Tsakalidou, E ‘Rapid
455
Assessment of the Physiological Status of Streptococcus macedonicus by Flow Cytometry and
456
Fluorescence Probes’. International Journal of Food Microbiology. 2006, 111 (3), 197-205.
457
23. Gunasekera, T.; Veal, D.;Attfield, P. ‘Potential for Broad Applications of Flow Cytometry
458
and Fluorescence Techniques in Microbiological and Somatic Cell Analyses of Milk’.
459
International Journal of Food Microbiology. 2003, 85 (3), 269-279.
460 461 462 463
24. Ramaiah, S.; Yew- Hoong Gin, Y.; Chit, Laa, P. 'Monitoring of Active but Non-Culturable Bacterial Cells by Flow Cytometry’. Biotechnology and Bioengineering. 2004, 89 (1), 24-31. 25. Bader, H. and Hoigene, J. 'Determination of ozone in water by the indigo method’. Water Research. 1981, 15, 449.
464
26. Joyce, E.; Phull, S.; Lorimer, P.; Mason, T. ‘The Development and Evaluation of
465
Ultrasound for the Treatment of Bacterial Suspensions. A Study of Frequency, Power and
466
Sonication Time on Cultured Bacillus Species’. UltrasonicsSonochemistry. 2007, 10 (6), 315-
467
318.
468
27. Joyce, E.; Al-Hashimi, A. and Mason, T.J. ‘Assessing the effect of different ultrasonic
469
frequencies on bacterial viability using flow cytometry’. 2011, Journal of Applied Microbiology,
470
110 (4).862–870
471
28. Joyce, E.M.; Mason, T.J.; Lorimer, J.P. ‘Application of UV radiation or electrochemistry in
472
conjunction with power ultrasound for the disinfection of water. Photo Electrochemical
473
Treatment of Water and Waste Water’. Journal of Environment and Pollution. 2007, 27 (1/2/3),
474
222-230
ACS Paragon Plus Environment
24
Page 25 of 25
Environmental Science & Technology
475
29. Foladori, P.; Laura, B.; Gianni, A.; Giuliano, Z. ‘Effects of Sonication on Bacteria
476
Viability in Wastewater Treatment Plants Evaluated by Flow Cytometry-Fecal Indicators,
477
Wastewater and Activated Sludge’. Water Research. 2007, 41 (1), 235-243.
478
30. Akbas, M. and Ozdemir, M. ‘Application of Gaseous Ozone to Control Populations of
479
Escherichia coli, Bacillus cereus and Bacillus cereus Spores in Dried Figs’.Food Microbiology.
480
2008, 25 (2), 386-391.31. Sharma,V. G.; Grahamb ,J.D. ‘Oxidation of Amino Acids, Peptides
481
and Proteins by Ozone: A Review., ozone’. Science & Engineering: The Journal of the
482
International Ozone Association. 2010, 32 (2). 81-90.
483 484
32. Jyoti, K. and Pandit, A. ‘Ozone and cavitation for water disinfection’. Biochemical Engineering Journal. 2004, 18(1), 9-19.
ACS Paragon Plus Environment
25