Comments on “Stoichiometry of Cr (VI) Immobilization Using

Stoichiometry of Cr(VI) Immobilization Using Nanoscale Zerovalent Iron (nZVI): A Study with High-Resolution X-Ray Photoelectron Spectroscopy (HR-XPS)...
0 downloads 0 Views 34KB Size
Ind. Eng. Chem. Res. 2009, 48, 2297

2297

CORRESPONDENCE Comments on “Stoichiometry of Cr(VI) Immobilization Using Nanoscale Zerovalent Iron (nZVI): A Study with High-Resolution X-Ray Photoelectron Spectroscopy (HR-XPS)” C. Noubactep* Centre of Geosciences, UniVersity of Go¨ttingen, Goldschmidtstrasse 3, D-37077 Go¨ttingen, Germany Li et al.1 have collected valuable data on the process of Cr(VI) removal in Fe0-H2O systems. They evaluated Cr(VI) reductive precipitation via nanoscale zerovalent iron (nZVI), using highresolution X-ray photoelectron spectroscopy (HR-XPS) and concluded that nZVI “mainly acts as a reductant” for Cr(VI) removal. The study of Li et al.1 is very informative to researchers interested in the field of iron technology. However, the given discussion should be regarded as a further propagation of a misconception for two major reasons. First: irrespective of the size of Fe0 material used (nanometer, micrometer, or millimeter scale), any Fe0-H2O system is a system that generates Fe(II) and Fe(III) species. Depending on the solution chemistry, both species may precipitate. During the course of precipitation, the available foreign species will be entrapped in their structure (coprecipitation). Contaminant coprecipitation should be primarily regarded as a nonspecific process. The relative proportion of foreign species in the coprecipitates depends on (i) the contaminant initial concentration, (ii) the initial Fe0 loading, and (iii) the reactivity of the Fe0 material used. If the contaminant is a metal (e.g., chromium) that is initially present at concentrations above the solubility limit (up to 2000 mg/L, or 38.5 mM in the Li et al.1 work (see ref 2 for the Cr(III) solubility limit)), the initial stage of the reaction will be characterized by the precipitation of contaminant, iron has been coprecipitated as the foreign species. The use of oversaturated metal concentrations is not justified because (i) oversaturation is rare in nature and (ii) in real-world systems, Fe0 is covered by a more or less thick layer of corrosion products (oxide film) before contaminant inflow occurs. Because Li et al.1 have not properly addressed these points, the relevance of their discussion for practical systems is yet to be demonstrated. In particular, there is no reason why Cr(VI) should be reduced to Cr(III) before precipitation. One should recall that an aqueous reduction of Cr(VI) by dissolved Fe(II) is favorable. On the other hand, coprecipitated Cr(VI) can be further reduced and adsorbed Fe(II) is a stronger reductant than dissolved Fe(II).3 A more coherent approach, which considers contaminant adsorption onto and/or contaminant coprecipitation with iron corrosion products to be a fundamental mechanism of contaminant removal in the Fe0-H2O system, has recently been introduced4,5 and is currently discussed in the literature.6,7 Second: Li et al.1 have shaken their reaction bottles at an intensity as high as 300 rpm. This operation has been proven disturbing for investigations of natural relevance.4,5,8 In fact, under such strong mixing regimes, the formation of an oxide film on Fe0 is disturbed (delayed or avoided). However, the aqueous reactivity of any metal (M0) is determined, in large part, by the transport properties of the corrosion product layer (oxide film) at its surface. Both ionic and electronic transport are important. The reactive metal substrate (M0) is seldom, if * To whom correspondence should be addressed. Tel.: +49 551 39 3191. Fax: +49 551 399379. E-mail address: [email protected].

ever, in direct contact with the electrolyte; instead, an oxide film separates the metal and the aqueous phase. If the oxide film is a barrier to transport (e.g., the oxide film on Al0), the corrosion rate is low and the metal is categorized as passive under the exposure conditions. If the oxide film is not a barrier (e.g., the oxide film on Fe0), corrosion proceeds.9 Therefore, for continued corrosion, an oxide film that is capable of high ionic transport is required at the M0 surface. The electronic transport properties will affect the spatial distribution of reduction reactions in the corroding system. With sufficient electronic conductivity, reduction reactions can proceed at the outer surface of the oxide film (i.e., the corrosion product can act as an electrode for electrochemical reactions).9 However, for Fe0, this electrochemical reaction path competes with indirect reduction through Fe(II), which may be more favorable.4,5 The aforementioned discussion demonstrates that the chemistry of the Fe0-Cr(VI)/H2O system was not properly considered by Li et al.1 The most important question for Fe0-H2O systems for Cr(VI) removal is (i) how long will Cr(VI) removal be successful? or (ii) what is the impact of Cr(VI) on the ionic and electronic transport properties of oxide films on Fe0 material? Answering this question for situations pertinent to natural systems is a challenge to the scientific community. In this effort, the use of ill-defined notion as “Fe0 removal capacity” should be avoided. Fe0 removal efficiency depends on the reactivity of Fe0, the flux of contaminant, and the water chemistry. Literature Cited (1) Li, X.-q.; Cao, J.; Zhang, W.-x. Stoichiometry of Cr(VI) Immobilization Using Nanoscale Zerovalent Iron (nZVI): A Study with High-Resolution X-Ray Photoelectron Spectroscopy (HR-XPS). Ind. Eng. Chem. Res. 2008, 47, 2131–2139. (2) Rai, D.; Eary, L. E.; Zachara, J. M. Environmental chemistry of chromium. Sci. Total EnViron. 1989, 86, 15–23. (3) White, A. F.; Peterson, M. L. Reduction of aqueous transition metal species on the surfaces of Fe(II)-containing oxides. Geochim. Cosmochim. Acta 1996, 60, 3799–3814. (4) Noubactep, C. Processes of contaminant removal in “Fe0-H2O” systems revisited. The importance of co-precipitation. Open EnViron. J. 2007, 1, 9–13. (5) Noubactep, C. A critical review on the mechanism of contaminant removal in Fe0-H2O systems. EnViron. Technol. 2008, 29, 909–920. (6) Ghauch, A.; Tuqan, A. Catalytic degradation of chlorothalonil in water using bimetallic iron-based systems. Chemosphere 2008, 73, 751– 759. (7) Simon, F. G.; Biermann, V.; Peplinski, B. Uranium removal from groundwater using hydroxyapatite. Appl. Geochem. 2008, 23, 2137–2145. (8) Grimm, R. D.; West, A. C.; Landolt, D. AC Impedance study of anodically formed salt films on iron in chloride solution. J. Electrochem. Soc. 1992, 139, 1622–1629. (9) Payer, J. H.; Ball, G.; Rickett, B. I.; Kim, H. S. Role of transport properties in corrosion product growth. Mater. Sci. Eng. A 1995, A198, 91–102.

IE801493U

10.1021/ie801493u CCC: $40.75  2009 American Chemical Society Published on Web 01/26/2009