CONOSTAN - Analytical Chemistry (ACS Publications)

May 24, 2012 - Chem. , 1976, 48 (14), pp 1175A–1175A. DOI: 10.1021/ac50008a757. Publication Date: December 1976. ACS Legacy Archive. Note: In lieu o...
0 downloads 0 Views 977KB Size
New Products

Models SF 770 continuously variable wavelength absorption monitor and FS 970 fluorescence detector are now available in one package. Confirmation of spectral characteristics of a compound can be accurately achieved by connecting the two units in series and carefully monitoring the results. Both units employ a high-energy, low stray light monochromator and offer a selection of light sources (deuterium and tungsten). Both have solid-state, miniaturized modular design and occupy a minimum of space. SF 770 priced at $4158 and FS 970 at $5200. Schoeffel Instrument Corp. 402

Atomic Absorption

Atomic Absorption

Spectrophotometer

Spectrophotometer

Model 370A features digital readout, automatic gain control, integrated readings, peak reader, easy concentration settings, 50X scale expansion, twostep curvature correction, and automatic zero. It is optimized for both flame and flameless sampling. The Model 370A is identical in its performance capability to the Model 370 but uses a different burner system and gas controls. Perkin-Elmer Corp. 417

Model SP2900 double-beam AA spectrophotometer features both peak height and peak area measurement. Timing for peak height measurement is from 0 to 99.9 s in 100-ms steps, and peak area integration is over a 4- or 10-s period. The instrument has 7-bar, bipolar illuminated digits. The range is - 0 . 0 5 to 1.999 A with a switchable decimal point and double over-range indication. Readout is in absorbance, concentration, or emission units, and digital update is 2.5X every second. It also features calibrated scale expansion from 0.2X to 50X and a background correction accessory. Patented burners are available in titanium jaw and stainless steel. Accessories available include the Model SP-01 gas control unit, SP450 automatic sample changer, and the SP9-01 digital flameless atomizer. Pye Unicam Ltd., York St., Cambridge, England

Glass Capillary C o l u m n s for GC The LKB 2101 capillary columns are wall-coated, narrow bore glass. The internal surface of the glass tubing is both physically and chemically treated to increase the adhesion of the stationary phase to the walls of the column. The columns are available in two grades, normal and high performance, with the following stationary phases available: polar-FFAP (SP1000), PPE2 1 , OV-225, Carbowax 20 m, OV-17 and nonpolar SE-30, and OV101 and AmAc (stationary phase for amino acid analysis). LKB Instruments, Inc. 412

For more information on listed items, circle the appropriate numbers on one of our Readers' Service Cards

M i c r o T L C S e p a r a t i o n s Kit Kit includes three micro developing tanks, a box of prescored TLC plates, precalibrated disposable micropipets, adsorbent scraper, and a Sprayon jet pack power kit for visualization. The kit can be used in the clinical laboratory, for teaching, and in a wide variety of industrial laboratories for quality control, pollution monitoring, etc. $59.95. Analtech, Inc. 420

Building Blocks for Spectrochemical Analysis.·· C0N0STAN standards are designed for metals in oil analysis by emission, atomic absorption, or X-ray fluorescence spectrometry. These standards are recognized for their high degree of compatability and stability. There are 29 elements as individual standards at 5000 ppm in light mineral oil for atomic absorption analysis. Mercury and arsenic are available at 100 ppm in light oil. C0N0STAIM blends of 12 or 20 metals in a heavy oil are widely accepted reference standards for wear metal analysis in lubricating oil. A blend containing Ca at 5 times the wear metal level is also available at the 20 metal level.

CONOSTAN CON0STAN DIVISION · Continental Oil Company P.O. Box 1267 · Ponca City, Oklahoma 74601

ANALYTICAL CHEMISTRY, VOL. 48, NO. 14, DECEMBER 1976 ·

1175 A