Bioinspired, Highly Stretchable, and Conductive Dry Adhesives Based

Mar 17, 2016 - Here we propose a concept of conductive dry adhesives (CDA) combining a gecko-inspired hierarchical structure and an elastomeric carbon...
0 downloads 16 Views 3MB Size
Subscriber access provided by University of Cincinnati Libraries

Article

Bio-Inspired, Highly Stretchable and Conductive Dry Adhesives based on 1D-2D Hybrid Carbon Nanocomposites for All-in-One ECG Electrodes Taehoon Kim, Junyong Park, Jongmoo Sohn, Donghwi Cho, and Seokwoo Jeon ACS Nano, Just Accepted Manuscript • DOI: 10.1021/acsnano.6b01355 • Publication Date (Web): 17 Mar 2016 Downloaded from http://pubs.acs.org on March 22, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

ACS Nano is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Bio-Inspired, Highly Stretchable and Conductive Dry Adhesives based on 1D-2D Hybrid Carbon Nanocomposites for All-in-One ECG Electrodes Taehoon Kim, † Junyong Park, †,¶ Jongmoo Sohn, ‡ Donghwi Cho,† and Seokwoo Jeon*,† †

Department of Materials Science and Engineering, KAIST Institute for The Nanocentury,

KAIST, Daejeon 34141, Republic of Korea ¶

Present address: Department of Chemical Engineering, Massachusetts Institute of Technology,

Cambridge, MA 02139, USA ‡

Wearable Computing Research Team, ETRI, Daejeon 34129, Republic of Korea

*

Correspondence should be addressed to S.J. (email: [email protected])

Keywords: Biomimetics, Stretchable conductors, Nanocomposites, Conductive dry adhesives, ECG electrodes

ACS Paragon Plus Environment

1

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 29

ABSTRACT: Here we propose a concept of conductive dry adhesives (CDA) combining a gecko-inspired hierarchical structure and an elastomeric carbon nanocomposite. To complement the poor electrical percolation of 1D carbon nanotube (CNT) networks in an elastomeric matrix at a low filler content (~1 wt%), a higher dimensional carbon material (i.e., carbon black, nano graphite, and graphene nanopowder) is added into the mixture as an aid filler. The co-doped graphene and CNT in the composite show the lowest volume resistance (~100 Ohm·cm) at an optimized filler ratio (1 : 9, total filler content: 1 wt%) through a synergetic effect in electrical percolation. With an optimized conductive elastomer, gecko-inspired high-aspect-ratio (>3) microstructures over large-area (~4 in2) are successfully replicated from intaglio patterned molds without collapse. The resultant CDA pad shows high normal adhesion force (~1.3 N/cm2) even on rough human-skin and excellent cyclic property for repeatable use over 30 times without degradation of adhesion force, which cannot be achieved by commercial wet adhesives. The body-attachable CDA can be used as a metal-free, all-in-one component for measuring biosignals under daily activity conditions (i.e., underwater, movements) because of its superior conformality and water-repellent characteristic.

ACS Paragon Plus Environment

2

Page 3 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Due to the great advances in flexible and stretchable materials, they have been extensively explored to realize smart, skin-like electronics for various ubiquitous applications, such as wearable energy modules,1-3 artificial tactile sensors,4-10 and epidermal medical patches.11-13 Such body-attachable electronic systems, in general, are made of two major components: a durable skin-adhesive and a stretchable circuit. For the latter part, researchers have focused on the development of highly stretchable and conductive electrodes composed of emerging architectures (serpentine or mesh) or elastomeric nanocomposites.11-14 However, the challenges for developing highly durable and non-irritable adhesives for human-skin and integrating those adhesives into skin-patch devices have limited the development due to the difficulty in the modification of wet adhesive chemistry. Recently, gecko-inspired structures consisting of hierarchically-structured, high-aspect-ratio micro- and nano-pillars have been proven to repeatedly adhere and detach from the rough surface of human-skin by collective van der Waals interaction.15,16 With optimization of the material and design, the adhesion force of geckoinspired dry adhesives on human-skin reaches ~1.8 N/cm2, comparable to that of commercial wet adhesives. A remaining issue for dry adhesive-based technologies is the relatively poor bonding at the interface between an elastomeric adhesive part and a metallic conductive part, which is essentially required for electrical interconnection with the upper circuit in device architectures. The metallic part in the integrated systems also strongly restricts the usability of dry adhesives for flexible and stretchable electronics, which should satisfy mechanical compliance: generally at least 30% deformation for human motion in daily life.17 Despite the significance of developing a united, multi-functional component endowing both adhesivity and conductivity, even in the bending and stretching states for practical applications, the current research and development

ACS Paragon Plus Environment

3

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 29

trend for dry adhesives have only focused on a mimicking strategy for gecko-like structures and their adhesion properties.18-21 Here, we first propose a single, stretchable and conductive dry adhesive (CDA) based on gecko-inspired architectures and nanocomposites. Unlike the existing dry adhesives that are generally made of insulating elastomer,18-21 the CDA developed here employs conductive elastomer composed of carbon nanofillers and poly(dimethylsiloxane) (PDMS). Two different forms of carbon nanomaterials, consisting of a one-dimensional (1D) carbon nanotube (CNT) and a two-dimensional (2D) graphene nanopowder, are simultaneously incorporated into an elastomeric matrix for a synergetic effect in electric percolation. Through the optimization of the ratio between the major and aid fillers, relatively high conductivity of the elastomer nanocomposites (~0.01 S/cm), which is enough to obtain bio-signals from human-skin,22 is achieved, even at a low-filler content (~1.0 wt%). A large-area CDA pad (~4 in2), which is attached to various conductive substrates with surface roughness ranging from 0.45 to 39.6 nm as electrical interconnection, successfully operates a light-emitting diode (LED) while bearing the heavy weight (~1 kg). The mechanical compliance of the CDA pad enables its utilization as a metal-free, all-in-one electrocardiogram (ECG) electrode with the integrated function of adhesion on human-skin. Highly-accurate ECG signals providing sufficient information to predict cardiovascular problems can be stably collected through the CDA pad, even in extreme moving states and underwater environments because of its superior conformality and waterrepellent characteristic, which cannot be achieved by conventional wet adhesive and metal electrode-based ECG systems.

RESULT AND DISCUSSION

ACS Paragon Plus Environment

4

Page 5 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Concept and Strategy for Realizing Conductive Dry Adhesives. Figure 1 describes the overall concept of this study. The fabrication procedure of the CDA pad begins with the design and preparation of gecko-inspired Si microstructures. The geometric parameter of gecko-inspired structures is one of the key factors determining the bulk adhesion of the resultant CDA pad. The shape and area of a spatula tip and the aspect-ratio of the supporting micropillars simultaneously influence on the contact area with a target substrate.23 To enhance the adhesion between the CDA pad and the rough surface of human-skin (RMS ~0.47 µm), a higher pillar with a wider spatula tip is required.15,16 Intaglio Si platforms containing square arrays of mushroom-shaped holes with aspect-ratios from 2 to 4 are prepared by photolithography and deep reactive ion etching (DRIE) processes using silicon-on-insulator (SOI) wafers (Figure S1).24 A wider spatula tip (~7 µm) at the bottom end of the holes compared to the diameter (~5 µm) of the holes can be achieved by excessive etching of SOI wafers during the DRIE process, which we refer to as a footing effect.25 The viscous PDMS prepolymer embedding 1D-2D hybrid carbon nanofillers with a low loading rate (~1 wt%) is dispensed on the Si platform and filled into high-aspect-ratio holes by vacuum-assisted capillary filling (Figure 1a). After optimal heat treatment to cure the prepolymer (~120 °C for 2 hours), which is a relatively harsh condition compared to that for curing normal PDMS because fillers generally act as crosslinking inhibitors,26 the CDA pad with mushroom-shaped micropillar arrays is inversely replicated from the Si platform. The resultant product can be directly applied to skin-attachable electronic systems, especially for ECG monitoring, as a metal-free single component because of its integrated functions of conductivity and adhesivity. The diffraction colors from the Si platform and the CDA pad and microstructures prove the successful fabrication with large-area uniformity (~4 in2) (Figure 1b). The large-area CDA pad can be wrapped on various curved surfaces of the human body due to its superior

ACS Paragon Plus Environment

5

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 29

flexibility and conformality (Figure 1c). The CDA pad almost preserves the intrinsic stretchability and bendability of the elastomer because minimized loading (~1.0 wt%) the conductive fillers in the composite is achieved through the synergetic percolation of 1D-2D hybrid carbon nanomaterials (Figure 1d and Figure S2). The successful LED operation using the CDA pad as an electrical interconnection with the bearing weight (~1 kg) experimentally supports that it can be potentially used for simplified skin-patch electronic systems as an integrated component, which plays two different roles of an electrode and an adhesive simultaneously (Figure 1e). Effect of Structural Factors of Conductive Dry Adhesives on Bulk Adhesion. Figure 2 addresses the relationship between the structural integrity of the high-aspect-ratio structures in the CDA pad and the bulk adhesivity. The mechanical compliance of micropillars on the CDA pad against the target surface is determined by functions of the elastic modulus of the materials and the aspect-ratio of the pillars. In general, high-aspect-ratio micropillars are desired to maximize the contact area and adhesion force between the CDA pad and the rough skin surface. However, the achievable aspect-ratio of the micropillars is limited by the intrinsic elastic modulus of constructing soft materials, which should overcome the critical elastic modulus at given geometrical conditions (i.e., height, radius, density and spacing) to prevent the lateral collapse of micropillars.27,28 The theoretical maximum height of micropillars without lateral collapse can be expressed by,



 =   

  

 



×

  (⁄ ) 

 



(1)

ACS Paragon Plus Environment

6

Page 7 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

where Eeff is the effective elastic modulus, R is the radius of the pillars, W is the period between neighboring pillars, and γs and ν are the surface energy and the Poisson’s ratio of the material, respectively. From Equation (1), the required elastic modulus of the construction materials for defect-free replication of micropillars can be extracted (Figure 2a). Two types of conductive elastomer with different moduli (~1.5 and ~3.5 MPa) are prepared by optimizing the amounts of the filler and the crosslinking agent to validate the theoretical prediction (Figure 2b). The diameter of the pillars is fixed at 5 µm, and the height of the pillars is varied from 10 to 20 µm. When the pillar height is 10 µm (i.e., the aspect-ratio is 2), the softer PDMS of ~1.5 MPa can support the structure without any lateral collapse. When the pillar height increases to ~15 µm, lateral collapse occurs in the case of softer PDMS, whereas defect-free replication is achieved using harder PDMS (~3.5 MPa). For taller pillars of ~20 µm, the PDMS cannot maintain the structural integrity, as expected by calculation. However, the harder PDMS shows a lower degree of lateral collapse per unit area compared to softer PDMS (Figure S3). The structural integrity of the CDA pads can also be visualized using 3D confocal microscopy because PDMS emits green photoluminescence (~560 nm) under 488 nm excitation (Figure 2c).29 The defect structures (i.e., lateral collapse and missing pillars) are sufficiently observable through the high-resolution confocal imaging (Figure 2d). This method is more advantageous for non-destructive inspection of structures compared to SEM imaging, which sometimes causes unwanted distortion of highaspect-ratio micropillars by an electron charging effect30 and essentially requires thin metal coating on polymeric surfaces. Through microstructure inspection, the relationship between the structural integrity and the bulk adhesion properties of the CDA pad are systematically analyzed as a function of the aspect-ratio of the micropillars. The average adhesion force of the CDA pads

ACS Paragon Plus Environment

7

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 29

is measured by a normal pulling test with a replicated skin surface as a target substrate (Figure 2e). The RMS value of the skin surface and the elastic modulus of the conductive PDMS used here are ~0.47 µm and 2.3 MPa, respectively. CDA pads with aspect-ratios ranging from 2 to 4 are repeatedly attached to and detached from the skin replica over 30 times with a preload ~0.5 N/cm2. During the cyclic measurement, cleaning of adhesives is performed by gentle-tapping with 3 M tape or DI water every 6 cycles (Figure 2f). As the aspect-ratio increases to 3 (identical to a pillar height of 15 µm), the adhesion force gradually improves to ~1.3 N/cm2, which is slightly higher than the average adhesion force (~1.1 N/cm2) of commercial wet adhesives (3 M) used 30 times. However, when the aspect-ratio of the pillars reaches ~4, the average adhesion force decreases due to lateral collapse between neighboring micropillars. Although the initial adhesion of the CDA pad with an aspect-ratio of ~4 is slightly stronger than that of the CDA pad with an aspect-ratio of ~3, the degradation of structural integrity is severe for the former case during repetitive compressive contact (Figure 2 g). The cyclic performance proves that the CDA pads perfectly recover their adhesive capability after surface cleaning, indicating that the pads are semi-permanently reusable, whereas the commercial wet adhesives rapidly lose their adhesion properties and cannot be restored even after cleaning. Electrical Properties of Conductive Dry Adhesives. Figure 3 shows the electrical characteristics of the CDA composed of 1D-2D hybrid carbon nanofillers and PDMS. First, the high-aspect-ratio (~1,000), multi-walled CNTs (M95, Carbon Nano-material Tech. Ltd.) are physically dispersed in PDMS prepolymer without chemical planetary mixing.31 After the crosslinking of the prepolymer by heat treatment, the solid film has a volume resistivity of ~12,000 Ohm·cm at a CNT content of 0.4 wt%. Although the resistivity can be reduced by ~150 Ohm·cm at a CNT content of 1.0 wt% (Figure S4), this value is still not sufficient for use in

ACS Paragon Plus Environment

8

Page 9 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

electronic devices; at least ~100 Ohm·cm is required to obtain meaningful bio-signals (P,QRS, and T curves) from ECG monitoring.22 PDMS prepolymer incorporated with CNTs over 1.0 wt% is difficult to use for capillary filling into micron-sized, deep-hole structures because the viscosity of prepolymer is too high due to the non-dispersed, entangled CNT clusters in the elastomeric matrix.32 A higher level of electrical properties while maintaining the low loading rate of the fillers in an insulating matrix requires the use of a co-doping system composed of 1D and 2D carbon nanofillers. With the CNTs as the main filler, which can form a major electrical path in the composite, wide and flat 2D carbon materials, including carbon black (CB), nanostructured graphite (NanoG), and graphene nanopowder (GNP) (Figure S5), are tested as a secondary aid-filler to enhance the electrical percolation. Except for the case of CB, which is apt to form aggregated clusters due to an extremely small average size (~15 nm) of particles, a small amount of GNP and NanoG in CNT-based composites with the optimized mixing ratio of 9:1 (CNTs: aid fillers) helps to reduce the volume resistivity below ~100 Ohm·cm, which represents ~ 33% enhanced conductivity compared to the composite containing only CNTs at the identical loading rate (Figure 3a).33 Among tested aid fillers, GNP shows the best material compatibility with CNT from the perspective of conductivity enhancement. Fixing the total filler content of GNP and CNTs at 1wt% in the CDA pad, the resistance change (∆/ ) is measured to evaluate the dynamic electrical behavior of CDA under stretching and bending. Although the resistance of the CDA pad is linearly increased before fracture (~100%), which is similar to the electrical behavior from other heterogeneous composite systems,34 the electrical performance at 30% elongation, represented as a stretching rate for human motion in daily living, is not significantly deteriorated (~14% decreased conductivity). The CDA pad has enormous merit in bending circumstances because a bending angle up to ~70 degrees does not affect the electrical properties

ACS Paragon Plus Environment

9

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 10 of 29

of the CDA (Figure 3b). From the morphology of the fractured surfaces, we can analogize the distribution of carbon nanofillers in the matrix and electrical paths (Figure 3c and d). A small amount of wide and flat 2D carbon fillers, such as graphene and graphite, plays a key role as an activator to revive the partially “dead” percolation region where the conductive path is disconnected.35,36 However, as the ratio of secondary 2D carbon fillers to CNTs increases in the composite film, the major electrical path is confused due to the exponentially increased areal coverage of 2D carbon fillers compared to CNTs, and the electrical synergetic effect between 1D and 2D carbon fillers disappears (Figure S6 and S7). The CB (~15 nm) is not large enough to connect the uncoupled percolation branches of CNTs but forms clusters around the already formed CNT networks. The LED arrays, electrically supplied by the attached CDA pad to various conductive substrates as an interconnecting layer withstanding the weight (~1 kg), demonstrate the useful conductivity of the 1D-2D carbon hybrid nanocomposite (Figure 3e). Au, ITO, FTO, and single-layer graphene are used as the top layer for conductive glass substrates with different surface roughness (Figure 3f). Although the light-emitting power of an LED is varied by the intrinsic resistance of the conductive substrates, the CDA pad successfully operates the LED arrays by strongly attaching to the conductive substrates, ignoring surface roughness (Figure 3g). Multifunctional Single Component for ECG Measurement. Figure 4 and 5 demonstrates the practical application of the CDA pad to ECG monitoring systems. One of the valuable properties of the CDA pad that distinguishes it from conventional ECG electrodes is the self-cleaning capability. The high-aspect-ratio micropillars with spatula tips greatly increase the contact angle between various types of liquid droplets (diethylene glycol, propylene carbonate, and DI water) and the CDA pad’s surface (Figure 4a and 4b).37 The contact angle between DI water and the

ACS Paragon Plus Environment

10

Page 11 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

CDA pad with a pillar aspect-ratio of ~3 reaches ~151° and other liquids droplets (i.e., diethylene glycol and propylene carbonate) are also show the similar large contact angle of ~ 140° (Figure 4c). This superhydrophobicity makes the CDA pad semi-permanently reusable by simply washing out the dust on its surface without pattern damages (Figure 4d and Movie S1) and enables the CDA pad to operate under immersed conditions by avoiding water-permeation. The multi-functionality (i.e., adhesivity, conductivity, and super-hydrophobicity) of the CDA pad is practically demonstrated through the ECG application. The CDA pad is directly connected to a wave simulator with the aid of an electric wire and is attached to three different positions (i.e., chest and left and right wrists) to obtain bio-signals from a heat rate. All measured ECG signals are filtered by an 8th-order low pass filter with a cutoff frequency of 40 Hz, followed by 60 Hz notch filtering. The heartbeat wave obtained from the CDA pad in a normal environment provides meaningful results with distinctly separated P, QRS, and T curves, which provide medical information about cardiovascular problems, with negligible fluctuation (Figure 5a). The recorded waveform is similar to that obtained from commercial ECG electrode systems (3 M). The CDA pad collects the long-term, intact bio-signals while maintaining conformal contact between the pad and human skin, even in an underwater environment, whereas wet adhesivebased commercial electrodes are immediately detached from the body and lose bio-signals within 5 sec due to water infusion at the edge of the adhesive (Figure 5b and Movie S2). Although the amplitude of signals measured under immersed conditions using the CDA pad is reduced by 25.6% compared to that measured under dry conditions, the recorded waveform accurately reflects the P, QRS, and T curves due to its superior conformality and water-repellent characteristic.38 The conformality of the CDA pad is also well-maintained during light and

ACS Paragon Plus Environment

11

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 29

extreme human motions (e.g., wrist curl, squat, and writing), facilitating real-time tracing of high-risk vascular diseases (e.g., arrhythmia and myocardial infarction) in daily life (Figure 5c).

CONCLUSIONS In this work, we demonstrate a new type of dry adhesives based on gecko-inspired microstructures and conductive elastomeric nanocomposites. The defect-free, replicated CDA pad with mushroom-like micropillars shows good cyclic adhesion (~30 times) with a normal adhesion force of ~1.3 N/cm2 on human skin, which is comparable to that of commercial wet adhesives. The 1D-2D carbon hybrid filler system is introduced to enhance the electrical percolation and to maximize the conductivity in the elastomer matrix at low concentration (~1 wt%) of fillers with an optimized mixing ratio of 9 : 1 (CNTs : Graphene). The composite film with optimized conditions possesses superior stretchability of over ~100% and electrical conductivity (~100 Ohm·cm) that is sufficient to operate LEDs. The CDA developed here has super-hydrophobic surfaces that have a self-cleaning capability, and it can be potentially applicable to ECG monitoring systems as a cost-effective and reusable all-in-one type electrode.

ACS Paragon Plus Environment

12

Page 13 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

MATERIALS AND METHODS Preparation of mushroom-shaped hole patterns. A mold containing mushroom-shaped hole arrays was fabricated by conventional photolithography and etching techniques. SOI wafers (Winwin Tech. Ltd.) composed of 3 layers (top bare silicon layer, BOX insulating layer (acting as an etching stop layer), and handle layer) were prepared. A top, bare silicon layer with three different thicknesses was used to fabricate three different pillar heights from 10 to 20 µm thickness with a step of 5 µm. In the first step, a negative photoresist (SU-8, MicroChem) was coated on the top bare silicon layer by spin-coating. Hole-patterns were made on the photoresist by conventional photolithography with a pre-patterned chrome mask with a square array of holes of 5 µm in diameter, followed by a developing process to remove uncured photoresist. Deep reactive-ion-etching was successively performed to create vertical holes in top layer until the exposure of the BOX layer. Under the equal etching condition, the top bare silicon layer was further etched in the lateral direction to fabricate mushroom-shaped pillars with tips. The tip width and thickness were controlled by the etching time. After the process, the micro-hole patterned SOI mold was treated with self-assembled-monolayer (SAM) solution. Preparation of conductive elastomers. The PDMS base (Sylgard 184, Dow Corning) and carbon nanofillers were first dispersed by hand using a spatula and were then mixed in a planetary mixer (ARE-310, Thinky) for 5 min at 2000 rpm and degassed for 1 min at 2200 rpm. Then, PDMS curing agent was added (10:1 ratio between the base and curing agent) and incorporated into the mixture by stirring manually before mixing again for 5 min at 2000 rpm and degassing for 1 s at 2200 rpm.

ACS Paragon Plus Environment

13

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 29

Fabrication of conductive dry adhesives. The prepared mixture composed of CNT, 2nd filler (CB, NanoG, or GNP), and PDMS was poured onto the micro-hole patterned SOI mold. Subsequently, a thin, flat backing layer of conductive dry adhesive was achieved through the spin-coating process (1000 rpm, 60 s). To degas bubbles in the composite mixture, the SOI mold with flat conductive elastomer was placed in a vacuum chamber for 1 hr, followed by curing at 120 ˚C for 2 hr. The cured conductive dry adhesives were carefully peeled off of the SOI mold. Bulk adhesion test of the conductive dry adhesives. Adhesion measurements were conducted with a pulling force sensor (FGJN-5B, Shimpo). To quantify the adhesion properties of the adhesives with skin, a skin replica was fabricated as follows. First, thermal-curable soft silicone resin (Ecoflex 0050, Smooth-on) was cast onto a volunteer’s arm and was cured for 30 min. The cured inverse-skin surface was peeled from the arm, and PUA (MINS-ERM, Minuta Tech.) was poured on the inverse-skin surface. After full-curing for 1 hr under a UV lamp (150 mW/cm2), the PUA skin replica was peeled off from the ecoflex mold. Sequentially, conductive dry adhesives were to the skin replica under a 0.5 N/cm2 preload. The adhesion force was measured by raising the sensor until adhesion failure. The adhesion test was conducted 30 times for each sample under the same conditions. The durability test of the conductive dry adhesives was also conducted for 30 repeating cycles, and each sample was cleaned every 6 cycles by scotch tape and a DI water wash. Electrical conductivity measurement of conductive dry adhesives. The top-bottom electrical conductivity of the micro-pillar arrays was calculated as: !=

" $ #%

ACS Paragon Plus Environment

14

Page 15 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

where I is the measured current, V is the applied voltage, t is the sample thickness measured by SEM and A is the sample/electrode contact area. The applied voltage and measured current were obtained using linear scan voltammetry in an electrochemical scanning system. The electrical robustness test was conducted using the same methods under stretching up to ~ 100% and bending up to a bending angle of 70 degrees. ECG signal measurement. Three identical conductive dry adhesives were prepared to acquire an ECG signal. The conductive dry adhesives for the medical skin patches were attached onto the volunteer’s forearm and left leg and the ECG module (ADS1x9x ECG-FE, Texas Instruments). Characterization. The micropillar structures and fracture surfaces of the co-doping composite were visualized via field-emission scanning electron microscopy (FESEM) (S-4800, Hitachi) at an accelerating voltage of 5-10 kV. The non-destructive surface profiles were directly captured using a confocal microscope (LV100POL, Nikon). The surface properties were analyzed using a contact angle goniometer (Phoenix 300, SEO).

ACS Paragon Plus Environment

15

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 29

Figure 1. Concept and strategy for realizing conductive dry adhesives. (a) A schematic illustration of the fabrication procedure for conductive dry adhesives and their application to ECG electrodes. (b) Digital images of a large-area silicon mold with gecko-inspired micropatterns and a replicated conductive dry adhesive (~ 4 in2). (c) Digital images of conductive dry adhesives conformally attached on human skin (i: wrist, ii: stomach, iii: ankle). (d) Digital images of the stretched and banded conductive dry adhesives. (e) A digital image of LED operation with a conductive dry adhesive as an interconnection.

ACS Paragon Plus Environment

16

Page 17 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Figure 2. Relationship between the structural integrity of high-aspect-ratio, gecko-inspired micropatterns and adhesivity. (a) A calculated optimal elastic modulus for preventing lateral collapse of micropatterns as a function of the aspect-ratio (AR). (b) Cross-sectional SEM images of the replicated micropatterns as a function of AR and the elastic modulus of the replicating

ACS Paragon Plus Environment

17

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 29

materials. (c) Non-destructive structural imaging via confocal microscopy (lower) and confirmation of its validity by SEM (upper). (d) Images indicating different types of defects, such as lateral collapse and missing. (e) Measured normal adhesion force on a skin replica as a function of pillar height (inset: a top-view SEM image of the skin replica). (f) Cyclic adhesion property of the conductive dry adhesives compared to a commercial 3 M wet adhesive. (g) SEM images of the micropatterns according to the cyclic use to demonstrate the degradation of structural integrity.

ACS Paragon Plus Environment

18

Page 19 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Figure 3. Electrical properties of the conductive dry adhesives. (a) Measured volume resistivity of the conductive dry adhesives consisting of 1D-2D hybrid carbon fillers with different composition ratios (main filler: CNT, total amount of filler: 1 wt%) (b) Resistance change of the

ACS Paragon Plus Environment

19

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 29

conductive dry adhesives under tensile stretching and bending. (c) SEM images of the fractured surfaces of conductive dry adhesives with various filler composition. (d) Schematic illustrations of the distribution of the fillers and electrical percolation in conductive dry adhesives matched with (c). (e) Digital images of the LED operation with conductive dry adhesives as interconnection attached on various conductive substrates (weight: 1 kg). (f) Surface profiles of various conductive substrates. (g) Relationship between the contact resistance and LED output.

ACS Paragon Plus Environment

20

Page 21 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Figure 4. Surface characteristics and washability of gecko-inspired, conductive dry adhesive (CDA) pads. (a) Cross-sectional images of liquid droplets (i.e., diethylene glycol, propylene carbonate, and DI water) on surfaces of gecko-inspired CDA and flat conductive pads. (b) Digital image of liquid droplets on the gecko-inspired CDA pad. (c) Comparison of contact angles between gecko-inspired CDA and flat conductive pads for various liquid droplets. (d) Demonstration of washability and reusability of the CDA pad (yellow arrows: dusts).

ACS Paragon Plus Environment

21

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 29

Figure 5. ECG measurement under various conditions. (a) Comparison of the ECG signals using conductive dry adhesives (CDA) and commercial electrodes with 3M adhesives under normal conditions (inset in the red box: a magnified view of the measured ECG wave indicating the P, QRS, and T waves). (b) Comparison of ECG signals using CDA and commercial electrodes with 3M adhesives under an immersed condition (inset in the lower graph: a magnified view of the detached commercial electrode due to water-intrusion). (c) Series of ECG signals using conductive dry adhesives under various movement conditions (i.e., wrist curl, squat, and writing).

ACS Paragon Plus Environment

22

Page 23 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

ASSOCIATED CONTENT Supporting Information. Additional figures and captions for schematic illustration of preparation steps for deep etched Si mold and the loss of the electrical synergetic effect in 1D-2D hybrid carbon nanocomposites with increasing the aid-filler ratio, mechanical properties (tensile elastic modulus) of 1D-2D hybrid carbon nanocomposites, SEM images for structural integrity of the mushroom-shaped micropillar arrays and fractured surface of hybrid carbon nanocomposites, TEM images for carbon nanomaterials used here in detail. This material is available free of charge via the Internet at http://pubs.acs.org. AUTHOR INFORMATION Corresponding Author *E-mail: [email protected]

Present address: Department of Chemical Engineering, Massachusetts Institute of Technology,

Cambridge, MA 02139, USA Notes The authors declare no competing financial interest.

ACS Paragon Plus Environment

23

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 24 of 29

ACKNOWLEDGMENT This work was supported by the ICT R&D program of MSIP/IITP. [B0101-15-0239, Human Friendly Devices (Skin Patch, Multi-modal Surface) and Device Social Framework Technology] and the Global Frontier Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (2014 M3A6B3063708).

REFERENCES 1.

Zhang, K.; Wang, X.; Yang, Y.; Wang, Z. L. Hybridized Electromagnetic–Triboelectric

Nanogenerator for Scavenging Biomechanical Energy for Sustainably Powering Wearable Electronics. ACS Nano 2015, 9, 3521-3529. 2.

Kim, S. L.; Choi, K.; Tazebay, A.; Yu, C. Flexible Power Fabrics Made of Carbon

Nanotubes for Harvesting Thermoelectricity. ACS Nano 2014, 8, 2377-2386. 3.

Kim, S. J.; We, J. H.; Cho, B. J. A Wearable Thermoelectric Generator Fabricated on a

Glass Fabric. Energy Environ. Sci. 2014, 7, 1959-1965. 4.

Park, J.; Lee, Y.; Hong, J.; Ha, M.; Jung, Y.-D.; Lim, H.; Kim, S. Y.; Ko, H. Giant

Tunneling Piezoresistance of Composite Elastomers with Interlocked Microdome Arrays for Ultrasensitive and Multimodal Electronic Skins. ACS Nano 2014, 8, 4689-4697. 5.

Park, H.; Jeong, Y. R.; Yun, J.; Hong, S. Y.; Jin, S.; Lee, S.-J.; Zi, G.; Ha, J. S.

Stretchable Array of Highly Sensitive Pressure Sensors Consisting of Polyaniline Nanofibers and Au-Coated Polydimethylsiloxane Micropillars. ACS Nano 2015, 9, 9974-9985. 6.

Amjadi, M.; Pichitpajongkit, A.; Lee, S.; Ryu, S.; Park, I. Highly Stretchable and

Sensitive Strain Sensor Based on Silver Nanowire–Elastomer Nanocomposite. ACS Nano 2014, 8, 5154-5163.

ACS Paragon Plus Environment

24

Page 25 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

7.

Hwang, B.-U.; Lee, J.-H.; Trung, T. Q.; Roh, E.; Kim, D.-I.; Kim, S.-W.; Lee, N.-E.

Transparent Stretchable Self-Powered Patchable Sensor Platform with Ultrasensitive Recognition of Human Activities. ACS Nano 2015, 9, 8801-8810. 8.

Ryu, S.; Lee, P.; Chou, J. B.; Xu, R.; Zhao, R.; Hart, A. J.; Kim, S.-G. Extremely Elastic

Wearable Carbon Nanotube Fiber Strain Sensor for Monitoring of Human Motion. ACS Nano 2015, 9, 5929-5936. 9.

Park, J.; Lee, Y.; Hong, J.; Lee, Y.; Ha, M.; Jung, Y.; Lim, H.; Kim, S. Y.; Ko, H.

Tactile-Direction-Sensitive and Stretchable Electronic Skins Based on Human-Skin-Inspired Interlocked Microstructures. ACS Nano 2014, 8, 12020-12029. 10.

Roh, E.; Hwang, B.-U.; Kim, D.; Kim, B.-Y.; Lee, N.-E. Stretchable, Transparent,

Ultrasensitive, and Patchable Strain Sensor for Human–Machine Interfaces Comprising a Nanohybrid of Carbon Nanotubes and Conductive Elastomers. ACS Nano 2015, 9, 6252-6261. 11.

Hwang, S.-W.; Lee, C. H.; Cheng, H.; Jeong, J.-W.; Kang, S.-K.; Kim, J.-H.; Shin, J.;

Yang, J.; Liu, Z.; Ameer, G. A.; Huang, Y.; Rogers, J. A. Biodegradable Elastomers and Silicon Nanomembranes/Nanoribbons for Stretchable, Transient Electronics, and Biosensors. Nano Lett. 2015, 15, 2801-2808. 12.

Yeo, W.-H.; Kim, Y.-S.; Lee, J.; Ameen, A.; Shi, L.; Li, M.; Wang, S.; Ma, R.; Jin, S. H.;

Kang, Z.; Huang, Y.; Rogers, J. A. Multifunctional Epidermal Electronics Printed Directly onto the Skin. Adv. Mater. 2013, 25, 2773-2778. 13.

Son, D.; Lee, J.; Qiao, S.; Ghaffari, R.; Kim, J.; Lee, J. E.; Song, C.; Kim, S. J.; Lee, D.

J.; Jun, S. W.; Yang, S.; Park, M.; Shin, J.; Do, K.; Lee, M.; Kang, K.; Hwang, C. S.; Lu, N.; Hyeon, T.; Kim, D.-H. Multifunctional Wearable Devices for Diagnosis and Therapy of Movement Disorders. Nat. Nanotechnol. 2014, 9, 397-404.

ACS Paragon Plus Environment

25

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

14.

Page 26 of 29

Park, J.; Wang, S.; Li, M.; Ahn, C.; Hyun, J. K.; Kim, D. S.; Kim, D. K.; Rogers, J. A.;

Huang, Y.; Jeon, S. Three-Dimensional Nanonetworks for Giant Stretchability in Dielectrics and Conductors. Nat. Commun. 2012, 3, 916. 15.

Ho, A. Y. Y.; Yeo, L. P.; Lam, Y. C.; Rodríguez, I. Fabrication and Analysis of Gecko-

Inspired Hierarchical Polymer Nanosetae. ACS Nano 2011, 5, 1897-1906. 16.

Kwak, M. K.; Jeong, H.-E.; Suh, K. Y. Rational Design and Enhanced Biocompatibility

of a Dry Adhesive Medical Skin Patch. Adv. Mater. 2011, 23, 3949-3953. 17.

Yamada, T.; Hayamizu, Y.; Yamamoto, Y.; Yomogida, Y.; Izadi-Najafabadi, A.; Futaba,

D. N.; Hata, K. A Stretchable Carbon Nanotube Strain Sensor for Human-Motion Detection. Nat. Nanotechnol. 2011, 6, 296-301. 18.

Jeong, H. E.; Suh, K. Y. Nanohairs and Nanotubes: Efficient Structural Elements for

Gecko-Inspired Artificial Dry Adhesives. Nano Today 2009, 4, 335-346. 19.

Hawkes, E. W.; Eason, E. V.; Christensen, D. L.; Cutkosky, M. R. Human Climbing with

Efficiently Scaled Gecko-Inspired Dry Adhesives. J. R. Soc., Interface 2014, 12. 20.

Lee, D. Y.; Lee, D. H.; Lee, S. G.; Cho, K. Hierarchical Gecko-Inspired Nanohairs with a

High Aspect Ratio Induced by Nanoyielding. Soft Matter 2012, 8, 4905-4910. 21.

Im, H. S.; Kwon, K. Y.; Kim, J. U.; Kim, K. S.; Yi, H.; Yoo, P. J.; Pang, C.; Jeong, H. E.;

Kim, T.-I. Highly Durable and Unidirectionally Stooped Polymeric Nanohairs for Gecko-like Dry Adhesive. Nanotechnology 2015, 26, 415301. 22.

Jung, H.-C.; Moon, J.-H.; Baek, D.-H.; Lee, J.-H.; Choi, Y.-Y.; Hong, J.-S.; Lee, S.-H.

CNT/PDMS Composite Flexible Dry Electrodes for Long-Term ECG Monitoring. IEEE Trans. Biomed. Eng. 2012, 59, 1472-1479.

ACS Paragon Plus Environment

26

Page 27 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

23.

Greiner, C.; del Campo, A.; Arzt, E. Adhesion of Bioinspired Micropatterned Surfaces:

Effects of Pillar Radius, Aspect Ratio, and Preload. Langmuir 2007, 23, 3495-3502. 24.

Jang, H.-I.; Ko, S.; Park, J.; Lee, D.-E.; Jeon, S.; Ahn, C. W.; Yoo, K. S.; Park, J. H.

Reversible Creation of Nanostructures Between Identical or Different Species of Materials. Appl. Phys. A: Mater. Sci. Process. 2012, 108, 41-52. 25.

Yisong, W.; Yunxia, G.; Haixia, Z. In Modeling and Simulation of Footing Effect in

DRIE Process, Nanotechnology, 2007. IEEE-NANO 2007. 7th IEEE Conference on 2007, 11351138. 26.

Li, Z.; Moon, K.-s.; Lin, Z.; Yao, Y.; Wilkins, S.; Wong, C. P. Carbon Nanotubes Inhibit

the Free-Radical Cross-Linking of Siloxane Polymers. J. Appl. Polym. Sci. 2014, 131. 27.

Zhang, Y.; Lo, C.-W.; Taylor, J. A.; Yang, S. Replica Molding of High-Aspect-Ratio

Polymeric Nanopillar Arrays with High Fidelity. Langmuir 2006, 22, 8595-8601. 28.

Park, J.; Park, J. H.; Kim, E.; Ahn, C. W.; Jang, H. I.; Rogers, J. A.; Jeon, S.

Conformable Solid-Index Phase Masks Composed of High-Aspect-Ratio Micropillar Arrays and Their Application to 3D Nanopatterning. Adv. Mater. 2011, 23, 860-864. 29.

Cesaro-Tadic, S.; Dernick, G.; Juncker, D.; Buurman, G.; Kropshofer, H.; Michel, B.;

Fattinger, C.; Delamarche, E. High-Sensitivity Miniaturized Immunoassays for Tumor Necrosis Factor α Using Microfluidic Systems. Lab on a Chip 2004, 4, 563-569. 30.

Kim, T.-I.; Jeong, H. E.; Suh, K. Y.; Lee, H. H. Stooped Nanohairs: Geometry-

Controllable, Unidirectional, Reversible, and Robust Gecko-like Dry Adhesive. Adv. Mater. 2009, 21, 2276-2281. 31.

Larmagnac, A.; Eggenberger, S.; Janossy, H.; Voros, J. Stretchable Electronics based on

Ag-PDMS Composites. Scientific Reports 2014, 4, 7254.

ACS Paragon Plus Environment

27

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

32.

Page 28 of 29

Suh, K. Y.; Kim, Y. S.; Lee, H. H. Capillary Force Lithography. Adv. Mater. 2001, 13,

1386-1389. 33.

Tang, Y.; Gou, J. Synergistic Effect on Electrical Conductivity of Few-Layer

Graphene/Multi-Walled Carbon Nanotube Paper. Materials Letters 2010, 64, 2513-2516. 34.

Chun, K.-Y.; Oh, Y.; Rho, J.; Ahn, J.-H.; Kim, Y.-J.; Choi, H. R.; Baik, S. Highly

Conductive, Printable and Stretchable Composite Films of Carbon Nanotubes and Silver. Nat. Nanotechnol. 2010, 5, 853-857. 35.

Sumfleth, J.; Adroher, X. C.; Schulte, K. Synergistic Effects in Network Formation and

Electrical Properties of Hybrid Epoxy Nanocomposites Containing Multi-Wall Carbon Nanotubes and Carbon Black. J. Mater. Sci. 2009, 44, 3241-3247. 36.

Ma, P.-C.; Liu, M.-Y.; Zhang, H.; Wang, S.-Q.; Wang, R.; Wang, K.; Wong, Y.-K.;

Tang, B.-Z.; Hong, S.-H.; Paik, K.-W.; Kim, J.-K. Enhanced Electrical Conductivity of Nanocomposites Containing Hybrid Fillers of Carbon Nanotubes and Carbon Black. ACS Appl. Mater. Interfaces 2009, 1, 1090-1096. 37.

Kim, J. H.; Shim, T. S.; Kim, S.-H. Lithographic Design of Overhanging Microdisk

Arrays Toward Omniphobic Surfaces. Adv. Mater. 2016, 28, 291-298. 38.

Reyes, B. A.; Posada-Quintero, H. F.; Bales, J. R.; Clement, A. L.; Pins, G. D.; Swiston,

A.; Riistama, J.; Florian, J. P.; Shykoff, B.; Qin, M.; Chon, K. H. Novel Electrodes for Underwater ECG Monitoring. IEEE Trans. Biomed. Eng. 2014, 61, 1863-1876.

ACS Paragon Plus Environment

28

Page 29 of 29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Insert Table of Contents Graphic and Synopsis:

A bio-inspired, conductive dry adhesive (CDA) is proposed to achieve single, integrated component electrodes and adhesives for measuring ECG signals on human-skin. The relationship between the structural integrity of high-aspect-ratio, gecko-like micropatterns and the adhesivity of CDA is systematically analyzed via theoretical prediction and experimental demonstration. Through the maximization of the electrical conductivity of CDA by incorporating 1D-2D hybrid carbon nanofillers into an elastomer matrix, even at a low filler content (~1 wt%), the CDA pad provides intact ECG signals comparable to commercial electrode systems. Overcoming the weaknesses of wet adhesives, various concepts, such as washability, reusability, and working capability in underwater conditions, are successfully demonstrated using CDA.

ACS Paragon Plus Environment

29