Subscriber access provided by READING UNIV
Article
Capture and Reductive Transformation of Halogenated Pesticides by an Activated Carbon-Based Electrolysis System for Treatment of Runoff Yuanqing Li, and William A. Mitch Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b05259 • Publication Date (Web): 27 Dec 2017 Downloaded from http://pubs.acs.org on December 30, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 34
Environmental Science & Technology
1
Capture and Reductive Transformation of Halogenated Pesticides by
2
an Activated Carbon-Based Electrolysis System for Treatment of
3
Runoff
4 5
Yuanqing Li1 and William A. Mitch1, *
6 7 8 9 10 11 12 13 14 15
1
Department of Civil and Environmental Engineering, Stanford University, 473 Via Ortega, Stanford, California 94305, United States
*Corresponding author: email:
[email protected], Phone: 650-725-9298, Fax: 650-723-7058
16 17 18 19 20 21
1
ACS Paragon Plus Environment
Environmental Science & Technology
22
Abstract
23
This study evaluates an electrochemical system to treat the halogenated pesticides,
24
fipronil, permethrin and bifenthrin, in urban runoff. Compared to the poor sorption
25
capacity of metal-based electrodes, granular activated carbon (GAC)-based electrodes
26
could sorb halogenated pesticides, permitting electrochemical degradation to occur
27
over longer timescales than reactor hydraulic residence times. In a dual-cell
28
configuration, a cathode constructed of loose GAC containing sorbed pesticides was
29
separated from the anode by an ion exchange membrane to prevent chloride transport
30
and oxidation to chlorine at the anode. When -1 V was applied to the cathode, fipronil
31
concentrations declined by 92% over 15 h, releasing molar equivalents of chloride (2)
32
and fluoride (6) suggesting complete dehalogenation of fipronil. An electrode
33
constructed of crushed GAC particles attached to a carbon cloth current distributor
34
achieved >90% degradation of fipronil, permethrin and bifenthrin within 2 h under the
35
same conditions. To evaluate a simpler single-cell configuration suitable for scale-up,
36
two of the carbon cloth-based electrodes were placed in parallel without an ion
37
exchange membrane. For -1 V applied to the cathode, fipronil degradation was >95%
38
over 2 h, and energy consumption declined with closer electrode spacing. However,
39
chloride oxidation at the anode produced chlorine, and the anode degraded. Application
40
of an alternating potential (-1 to +1 V at 0.0125 Hz) to the parallel-plate electrodes
41
achieved >90% degradation of fipronil, bifenthrin and permethrin over 4 h, releasing
42
chloride at 50-70% of that expected for complete dechlorination. No loss of
43
performance or formation of chlorine or halogenated byproducts was observed over 5 2
ACS Paragon Plus Environment
Page 2 of 34
Page 3 of 34
Environmental Science & Technology
44
cycles of treating fipronil-spiked surface water.
45
3
ACS Paragon Plus Environment
Environmental Science & Technology
46
Introduction
47
The halogenated phenylpyrazole pesticide, fipronil, and the pyrethroid
48
insecticides, bifenthrin and permethrin, are widely used to control termites, ants,
49
cockroaches, and wasps around houses, and to repel ticks on pets.1 Their use has
50
raised concerns about potential adverse impacts on non-target insects, such as
51
honeybees,2 and on organisms in surface waters impacted by urban runoff.3 For
52
example, although the activity of fipronil is somewhat selective for insects over
53
vertebrates,4,5 fipronil exhibits toxicity to many fish, birds and mammals.6-11 Previous
54
research has demonstrated the biotransformation of fipronil to fipronil sulfide under
55
reducing conditions or fipronil sulfone under oxidative conditions.12-15 However, these
56
metabolites exhibit toxicity similar to fipronil.5,10,11,16
57
Fipronil and its degradation products, fipronil sulfone and fipronyl desulfinyl,
58
were detected with frequencies of 49%, 43% and 33%, respectively, in a California
59
statewide survey of >500 urban surface water samples.17 For 46% of the samples,
60
fipronil concentrations exceeded the 11 ng/L associated with chronic toxicity to aquatic
61
life. Fipronil loadings frequently were associated with stormwater runoff. However,
62
at one site fipronil loadings were higher during the dry season, suggesting mobilization
63
of fipronil applied at homes by household irrigation systems17. Similarly, the toxicity
64
measured in samples of residential runoff and two urban creeks in California to aquatic
65
amphipods was attributed to pyrethroids, including bifenthrin.3
66
Capturing and degrading these halogenated pesticides in stormwater runoff before
67
they reach surface waters could permit their continued use while avoiding these adverse 4
ACS Paragon Plus Environment
Page 4 of 34
Page 5 of 34
Environmental Science & Technology
68
impacts. Treatment systems for this type of non-point source contamination should be
69
cheap, and require minimal maintenance. Activated carbon could be used to capture
70
pesticides from stormwater, but the carbon would need to be periodically replaced to
71
prevent contaminant breakthrough. To eliminate the cost of activated carbon
72
replacement and disposal, it would be desirable to treat the activated carbon in situ to
73
destroy the sorbed pesticides. Previously, we demonstrated the capture on granular
74
activated carbon (GAC) of halogenated disinfection byproducts (DBPs) from reverse
75
osmosis permeate associated with the advanced treatment for the potable reuse of
76
municipal wastewater.18 The GAC was periodically converted into a cathode within
77
an electrochemical cell to achieve reductive electrolytic dehalogenation of the sorbed
78
DBPs, achieving >90% dehalogenation of 13 DBPs after 6 hours of treatment at -1 V
79
vs. Standard Hydrogen Electrode (S.H.E.). The GAC was reused over multiple cycles
80
of DBP capture and regeneration without loss of degradation efficiency. Similarly, we
81
demonstrated the ability of the GAC-based electrolysis system to capture gas phase
82
methyl bromide effluents relevant to post-harvest fumigation scenarios19,20. The GAC
83
bed was regenerated by submerging it in water and applying a negative potential to the
84
carbon to achieve ~80% reductive debromination of methyl bromide over 30 hours at
85
-1 V vs. S.H.E.
86
For these initial applications, the loose GAC particles in the cathode were wrapped
87
with sheet graphite to distribute the current. Recognizing that resistance between the
88
loose GAC particles within the bed might limit the efficiency of reductive
89
dehalogenation, we developed an improved electrode consisting of finely-ground GAC 5
ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 34
90
particles coated onto carbon cloth as a current distributor.
The 3.3-fold lower
91
resistance of this cathode increased the efficiency of methyl bromide debromination to
92
~80% over 2 hours at -1 V vs. S.H.E20.
93
A long-term goal is to develop an electrolysis system to capture and degrade
94
pesticides in urban runoff using GAC-based electrodes. Preparatory to developing a
95
pilot-scale system, the objective of this work was to characterize a GAC-based
96
electrolysis system capable of achieving reductive dehalogenation of sorbed
97
halogenated pesticides without generating undesirable halogen-based oxidants as
98
byproducts. The first objective was to demonstrate the degradation of fipronil,
99
bifenthrin and permethrin using a cathode constructed of either loose GAC particles
100
wrapped in sheet graphite or GAC particles bound to carbon cloth within a two-cell
101
electrochemical configuration (Figure S1B). This configuration encompassed the
102
GAC-based cathodes and a platinum wire anode in different cells separated by a cation
103
exchange membrane to prevent the passage of halides released from the cathode to the
104
anode, where oxidation could generate undesirable oxidants such as chlorine. This
105
configuration was used to demonstrate the quantitative yield of halides via reductive
106
dehalogenation of the 2 chlorine and 6 fluorine functional groups in fipronil. Halogens
107
are common functional groups in pesticides and are frequently associated with toxicity
108
across a range of environmental contaminants (e.g., DBPs, perfluorinated compounds).
109
The second objective of the current study was to evaluate modifications to simplify the
110
electrode configuration and render it suitable for pilot-scale systems.
111
GAC/carbon cloth electrodes were placed in a close, parallel-plate configuration within 6
ACS Paragon Plus Environment
Two
Page 7 of 34
Environmental Science & Technology
112
a single cell (Figure S1C) to reduce the full-cell voltage and avoid the cost of the
113
platinum anode. The system was operated in a direct current (DC) configuration
114
wherein electrochemical reductive dehalogenation was targeted on the cathode by
115
application of a constant potential. The third objective was to assess the use of
116
alternating current (AC) electrolysis, where the polarity of the electrodes is periodically
117
reversed, within the parallel-plate electrode configuration (Figure S1C).
118
environmental applications of electrolysis systems have focused on DC systems21,
119
wherein only one electrode could participate in reductive dehalogenation. In addition
120
to permitting both GAC-based electrodes to participate in reductive dehalogenation, we
121
demonstrate that AC electrolysis may avoid the need for the cation exchange
122
membrane if the frequency is sufficient to avoid transport and oxidation of halides
123
between the electrodes.
124
Materials and Methods
Most
125
Electrode preparation: GAC particles were ground and sieved to 40-60 mesh size,
126
and then rinsed three times with deionized water and oven-dried overnight before
127
further use. In this study, two different GAC-based working electrodes were
128
constructed. For preparation of a working electrode consisting of loose GAC particles
129
wrapped in sheet graphite (GAC/graphite electrodes), 0.8 g of Norit GAC was stirred
130
with 12.5 mg/L fipronil in 24 mL deionized water. While this fipronil concentration
131
exceeded its solubility, >99% of fipronil partitioned to the GAC within 20 min, as
132
verified by measurement of the aqueous phase. The GAC was filtered and split into
133
eight equal portions (0.1 g dry carbon equivalent). Two of the portions were extracted 7
ACS Paragon Plus Environment
Environmental Science & Technology
134
with 4 mL acetonitrile (80% extraction efficiency) to validate the sorbed fipronil
135
concentration (375 µg/g or 0.86 µmol/g). Another two of the portions were transferred
136
into sheet graphite tubes (~ 0.5 cm × 1 cm) and submerged in 40 mL of deionized water
137
buffered at pH 7 with 0.1 M phosphate buffer to serve as controls. The remaining four
138
portions of GAC (containing 0.34 µmol fipronil) were transferred into a similar sheet
139
graphite tube (~ 0.5 cm × 2 cm) and submerged in 150 mL phosphate buffer at pH 7 to
140
serve as the working electrode for electrolysis.
141
The GAC/carbon cloth-based electrodes were fabricated using the method
142
described by Xie et al.22 Briefly, Norit GAC particles were ground into smaller particles
143
via ball milling (planetary ball mill, Nanjing T-Bota Scietech Instruments & Equipment
144
Co., Ltd., Nanjing, China, 400 rpm for 10 h). An ink was made by mixing fine GAC
145
particles (92% dry weight) and PVDF (8% dry weight) in NMP solvent in a weight
146
ratio of 1:5 for GAC/PVDF to NMP and stirring overnight. A piece of carbon cloth (6
147
cm × 2 cm × 0.38 mm) was used as the current distributor and coated with the GAC ink
148
(Figure S1A). A titanium wire was attached to the carbon cloth to convey current to the
149
electrode. The electrodes were dried in a vacuum overnight, resulting in a total GAC
150
mass loading of ∼0.2 g/electrode (17 mg/cm2). The electrodes were pre-treated by
151
electrolysis at -1.0 V vs S.H.E. for 15 h (see below for electrolysis details) to remove
152
surface-associated chloride. The electrode was oven-dried for 4 h at 100°C and then
153
stored under vacuum.
154
Dual cell DC electrolysis: Electrolysis within a conventional dual cell laboratory
155
configuration was conducted similarly to our previous studies (Figure S1B).20,22 The
156
system consisted of two 150 mL chambers separated by a cation exchange membrane
157
(Ultrex CMI-7000, Membranes International, Ringwood, NJ). For the GAC/carbon 8
ACS Paragon Plus Environment
Page 8 of 34
Page 9 of 34
Environmental Science & Technology
158
cloth electrode, fipronil was sorbed to the electrode by submerging in deionized water
159
containing 1 mg/L (23 µM or 3.5 µmol) fipronil and 1-100 mM phosphate buffer (pH 7)
160
or 1 mM chloride within the cathodic chamber; this pH and the lower range of salt
161
concentrations approximate those in the freshwaters characteristic of stormwater (see
162
Lake Lagunita water characteristics below). After stirring for 2 h, 91% of the fipronil
163
(3.2 µmol) was sorbed to the electrode. In a separate experiment, a mixture of 150 µg
164
each of fipronil, bifenthrin and permethrin were sorbed from a stirred 100 mM
165
phosphate buffer (pH 7) to the GAC/carbon cloth electrode. A Ag/AgCl reference
166
electrode (CHI111, porous Teflon tip, CH Instruments, Austin, TX, USA) was placed
167
in the cathode chamber within 1 cm of either the GAC/carbon cloth cathode or the
168
GAC/graphite cathode (pre-loaded with fipronil), and a platinum wire (CH
169
Instruments) was placed in the anode chamber as the counter electrode. A CH-600D
170
potentiostat (CH Instruments, Austin, TX) applied constant potentials ranging from
171
-0.2 to -1.0 V vs S.H.E. to the cathode via a titanium wire. The cathode solution was
172
stirred with a Teflon-coated magnetic stir bar.
173
Single cell DC or AC electrolysis: Two planar GAC/carbon cloth electrodes (5 cm
174
× 10 cm) were fashioned as described above. For DC electrolysis, one electrode was
175
spiked directly by distributing 50 µL of a 10 g/L fipronil stock in acetonitrile (500 µg)
176
over the electrode; this electrode served as the cathode. The second electrode served
177
as the anode. The cathode and anode were held in plastic frames in a parallel
178
configuration using 4 ceramic insulating spacers to maintain specific separation
179
distances (1.5-3.0 cm; Figure S1C). The electrodes were placed in 500 mL of 0.1 M
180
phosphate-buffered deionized water at pH 7 (corresponding to 1 mg/L fipronil if
181
dissolved in the water) within a plastic box. Solutions were stirred with a
182
Teflon-coated magnetic stir bar. Controls without the GAC/carbon cloth electrode 9
ACS Paragon Plus Environment
Environmental Science & Technology
Page 10 of 34
183
indicated no significant sorption of fipronil to the plastic box or frames. Electrolysis
184
was conducted by applying a constant voltage of -1 V vs. S.H.E. to the cathode. The
185
current delivered to the cathode were measured by the potentiostat.
186
voltage was determined by measuring the potential difference between the cathode
187
and anode using a multimeter.
The full-cell
188
For AC electrolysis, each electrode was spiked with 500 µg of either fipronil,
189
bifenthrin or permethrin and the electrodes were assembled in a parallel-plate
190
configuration separated by 2.2 cm (Figure S1C). Alternating current with a triangular
191
waveform was applied using the cyclic voltammetry scan function of the potentiostat.
192
The voltage was scanned between -1 V and 1 V vs. S.H.E. at scan rates ranging from
193
0.01-0.1 V/s (i.e., 0.0025-0.025 Hz). To investigate chlorine evolution, similar
194
experiments were conducted in the presence of 1 mM chloride; aliquots withdrawn
195
periodically from the aqueous phase were measured for total chlorine residual by the
196
DPD colorimetric method.23
197
For an initial assessment of the impact of natural water constituents on the
198
long-term performance of AC electrolysis, 5 cycles of electrolysis were performed
199
using a filtered sample collected from Lake Lagunita (pH 7.0, 12.7 mg/L dissolved
200
organic carbon, 11.4 mg/L chloride and 65 µg/L bromide), a seasonal lake on the
201
Stanford University campus. The single cell AC electrolysis apparatus was loaded
202
with Lake Lagunita water (500 mL) spiked with 1 mg fipronil and stirred for 4 h
203
without electrolysis, permitting competition for sorption between fipronil and other
204
constituents (e.g., organic matter). AC electrolysis was then conducted (0.05 V/s or
205
0.0125 Hz) for 4 h.
206
fipronil and potential byproducts (e.g., fipronil sulfide) over the 8 h cycle. The
207
electrodes were then extracted for analysis of residual fipronil and byproducts. In a
Aqueous samples were periodically withdrawn for analysis of
10
ACS Paragon Plus Environment
Page 11 of 34
Environmental Science & Technology
208
separate experiment, this process was repeated, but after the 4 h electrolysis, the
209
electrodes were not extracted, and the solution was immediately replaced with a fresh,
210
fipronil-spiked aliquot of Lake Lagunita water to commence another cycle of sorption
211
and electrolysis.
212
residual fipronil and byproducts.
213
1 and 5 cycles of sorption/electrolysis to detect performance degradation resulting
214
from exposure to natural water constituents.
After 5 such cycles, the electrodes were extracted to measure The electrode performance was compared between
215 216
Results and Discussion
217
Text S1 provides materials sources and analytical methods.
218
Dual-cell DC electrolysis: Initial experiments compared the performance of the
219
GAC/graphite and GAC/carbon cloth cathodes using 100 mM phosphate buffer at pH 7
220
within a conventional dual cell laboratory electrolysis configuration, in which the
221
cathodes were separated from a platinum wire anode by a cation exchange membrane
222
(Figure S1B). For treatment of fipronil with the GAC/graphite electrode, fipronil was
223
not measureable in the aqueous phase of the cathode cell throughout the experiment,
224
reflecting its strong sorption to the GAC. After application of a constant -1 V vs.
225
S.H.E. potential to the cathode for 15 h, the sorbed fipronil declined by 92% from 0.34
226
µmol to 0.03 µmol. Fipronil sulfide, a reduction product of fipronil, was not detected,
227
but 0.71 µmol chloride (206% molar yield) and 1.97 µmol fluoride (572% molar yield)
228
were measured in the aqueous phase, indicating nearly complete dehalogenation of the
229
2 chlorine and 6 fluorine substituents in fipronil (Figure 1A). Fipronil loss and
230
formation of fipronil sulfide, fluoride and chloride were not observed for the 11
ACS Paragon Plus Environment
Environmental Science & Technology
231
GAC/graphite cathode control to which no potential was applied.
232
Upon application of a constant -1 V vs. S.H.E. potential to the GAC/carbon cloth
233
cathode at pH 7, the 3.2 µmol of fipronil initially sorbed to the cathode declined 78%
234
within 1 h, 95% within 2 h and 99% within 15 h (Figure 1B). Low levels of the
235
reduction product, fipronil sulfide (which retains the 2 chlorine and 6 fluorine
236
substituents), were measured on the cathode, reaching 14% yield after 2 h, but declined
237
to permethrin > bifenthrin (Figure 1D). At
266
-0.2 V, 90%. The reductive dechlorination of permethrin and bifenthrin are
268
discussed later in the context of AC electrolysis experiments. All further experiments
269
were conducted at -1 V vs. S.H.E. to ensure efficient pesticide degradation.
270
Single-cell DC electrolysis: It was hypothesized that a single-cell, parallel-plate
271
configuration of the GAC/carbon cloth electrodes would increase the degradation
272
efficiency by decreasing the resistance; the rationale for this hypothesis is discussed
273
below. This configuration may also be simpler for pilot-scale treatment of a water
274
stream. Two planar GAC/carbon cloth electrodes were configured in parallel, and 13
ACS Paragon Plus Environment
Environmental Science & Technology
275
separated by 1.5, 2.2 or 3.0 cm without an intervening cation exchange membrane
276
(Figure S1C); the electrode serving as the cathode had previously been spiked with 500
277
µg fipronil. When -1 V vs. S.H.E. was applied to the cathode at pH 7 (100 mM
278
phosphate buffer), fipronil loss after 2 h was >95% and comparable for all three
279
electrode spacings (i.e., 97%, 95% and 95% removal for the 1.5, 2.2 and 3.0 cm
280
spacings, respectively). The release of chloride was somewhat higher for the closest
281
spacing of the electrodes, but in all cases reached at least 50% of the molar yield
282
expected for complete dechlorination within 2 h (Figure 2A). No significant chloride
283
release was detected in the control to which no potential was applied.
284
However, there were two significant problems with the single-cell DC
285
configuration. First, GAC particles were observed to shed from the anode, likely
286
reflecting the instability of the PVDF binding agent when high potentials were applied
287
to the anode; towards the beginning of the electrolysis, the anode potential often
288
exceeded +2 V vs. S.H.E. To restore the activity of the electrode, it was re-coated with
289
the carbon-based ink after every 5 experiments. Second, when the reaction was
290
conducted using 1 mM NaCl, a concentration relevant to freshwater (35 mg/L),
291
production of free chlorine was observed (Figure 3) resulting from chloride oxidation at
292
the anode (equation 1); based on the full-cell voltage (Figure 2B), the anode potential
293
after ~20 min was ~1-2V vs. S.H.E. depending on the electrode spacing. Although
294
similar, free chlorine formation was somewhat faster during the initial stages of the
295
electrolysis when the 1 mM NaCl was buffered with 100 mM phosphate (Figure S2)
296
than when unbuffered (Figure 3). In the dual-cell configuration, the cation exchange 14
ACS Paragon Plus Environment
Page 14 of 34
Page 15 of 34
Environmental Science & Technology
297
membrane avoids free chlorine production at the anode by preventing the transport of
298
chloride from the water sample to the anode. While the absence of the cation exchange
299
membrane simplifies the single-cell configuration, release of free chlorine produced at
300
the anode into the effluent water would present a risk to organisms in receiving waters
301
and would generate undesirable byproducts of free chlorine reactions with organic
302
matter.
303
Cl- + H2O → HOCl + 2 e- + H+
[1]
304
Single-cell AC electrolysis: The performance of AC electrolysis was evaluated in the
305
parallel-plate (2.2 cm spacing) single-cell configuration (Figure S1C) with each of the
306
GAC/carbon cloth electrodes spiked with 500 µg (1.15 µmol) fipronil (i.e., 1 mg total).
307
The potential applied to one electrode (as measured using an adjacent reference
308
electrode) was varied using a triangular waveform from -1 to +1 V vs. S.H.E. at scan
309
rates of 0.01, 0.05, and 0.1 V/s (i.e., frequencies of 0.0025-0.025 Hz). The residual
310
fipronil on the electrodes measured after 4 h of electrolysis indicated 98%, 96% and 93%
311
removal for frequencies of 0.0025-0.025 Hz, respectively. The electrolysis treatment
312
time was twice as long as for the single-cell DC experiments, in recognition of the fact
313
that the electrodes were experiencing a negative potential only half of the time.
314
For all three frequencies, ~60% dechlorination (i.e., chloride liberation relative to
315
the total chlorine in fipronil) was achieved after 4 h (Figure 4), comparable to the
316
dechlorination observed after 2 h of DC electrolysis (Figure 2A). However, the chloride
317
yield rate was slower during the first 90 min for the highest frequency (0.025 Hz). One
15
ACS Paragon Plus Environment
Environmental Science & Technology
318
potential explanation for the slower release of chloride at higher frequency is that the
319
shorter duration during which the electrodes were held at negative potentials within
320
each cycle hindered the reduction reaction.
321
When 1 mg of either bifenthrin or permethrin was treated by AC electrolysis (-1 V
322
to 1 V vs. S.H.E. at 0.025 Hz), 91% of bifenthrin and 92% of permethrin were degraded
323
after 4 h of treatment, similar to the percent of fipronil removed; no significant decay of
324
bifenthrin or permethrin were observed in the absence of applied voltage. The percent
325
dechlorination was even higher than for fipronil, reaching ~70% for both compounds
326
after 4 h (Figure S3). These results suggest that AC electrolysis could be used as a
327
non-selective technique for the treatment of halogenated pesticides in water.
328
Free chlorine formation from 1 mM chloride solutions was near 4 µM (0.3 mg/L as
329
Cl2) for all cases except the lowest frequency (0.0025 Hz) in the presence of 100 mM
330
phosphate buffer (Figures 3 and S2); chlorate and perchlorate were never observed.
331
These results suggest that the lowest frequency permits a sufficient duration at a
332
positive potential for chloride oxidation to occur. When the AC electrolysis was
333
conducted with 1 mM chloride, but without 100 mM phosphate buffer, a scenario
334
relevant to freshwater ionic strength, significant free chlorine accumulation was not
335
observed (Figure 3). The significant reduction in free chlorine production without the
336
use of an ion exchange membrane is a major advantage to the use of AC electrolysis
337
over DC electrolysis. However, the intermediate frequency (0.0125 Hz) may represent
338
a compromise between high dechlorination rates for fipronil and minimizing free
339
chlorine production. 16
ACS Paragon Plus Environment
Page 16 of 34
Page 17 of 34
Environmental Science & Technology
340
Another advantage for AC electrolysis is that no significant electrode
341
decomposition was observed during AC electrolysis, perhaps due to the limited
342
duration during which the electrodes were subjected to anodic potentials during each
343
cycle. To further explore the stability of electrode performance, 500 mL of an authentic
344
surface water (Lake Lagunita at Stanford University) spiked with 1 mg (2.3 µmol)
345
fipronil was treated by AC electrolysis. First, the solution was stirred for 4 h and the
346
aqueous concentration of fipronil was measured to monitor sorption of fipronil to the
347
electrodes in competition with other solution components (e.g., 12.7 mg/L DOC). The
348
aqueous fipronil concentration declined by 80% after 4 h (Figures 5 and S4). Then AC
349
electrolysis (2.2 cm electrode spacing and 0.0125 Hz with the applied voltage ranging
350
from -1 to +1 V) was conducted for 4 h, after which the aqueous fipronil concentration
351
had declined to 1% of its initial value (Figure S4). Due to the background chloride
352
concentration in the water sample, we were not able to measure the chloride yield from
353
the electrolytic degradation of fipronil. The residual fipronil extracted from the two
354
electrodes accounted for 3.0 ± 0.5 % and 3.0 ± 0.3% of the initial fipronil mass,
355
indicating a total removal of 92.9% ± 0.8 % of the initial fipronil mass during the 8 h
356
sorption and AC electrolysis cycle.
357
This treatment was then repeated over 5 cycles of sorption and AC electrolysis
358
treatment of spiked 500 mL water samples, but the electrodes were extracted to
359
measure residual fipronil only after the final treatment cycle (Figure 5). The fipronil
360
removal profile was similar across all five cycles, with only 2% of the initial fipronil
361
mass measured in the aqueous phase after AC electrolysis during the fifth cycle. The 17
ACS Paragon Plus Environment
Environmental Science & Technology
362
residual fipronil extracted from the two electrodes after the fifth cycle represented 5.0 ±
363
0.4 % and 5.0 ± 1.1 % of the initial fipronil mass added during the fifth cycle.
364
Comparing the residual aqueous fipronil concentrations measured after each cycle and
365
the residual fipronil extracted from the electrodes after the fifth cycle to the total
366
fipronil mass added over all 5 cycles indicates a total removal rate over 5 cycles of 95.9
367
± 0.5%. These results suggest that the performance of the electrode did not decline over
368
time despite the potential for blockage of sorption sites by other matrix constituents,
369
including NOM. The slight increase in residual fipronil sorbed to the electrodes over
370
several cycles likely could be degraded by prolonging the electrolysis duration. The
371
only halogenated DBP measured in the aqueous phase after AC electrolysis treatment
372
of Lake Lagunita water was 0.2 µg/L of 1,1,1-trichloropropanone, indicating that AC
373
electrolysis can mitigate the production of halogenated byproducts.
374
To further test the importance of NOM blockage of GAC pore sites, the two
375
GAC/carbon cloth electrodes were exposed to 100 mg/L of Aldrich humic acid for 72 h.
376
The electrodes were then used to treat 500 mL Lake Lagunita water spiked with 1 mg
377
fipronil over one cycle of AC electrolysis as described above. After the 4 h of sorption
378
and 4 h of AC electrolysis, the overall decay of fipronil retrieved from both the aqueous
379
phase (Figure S5) and the GAC/carbon cloth electrodes was 98%, comparable to that
380
observed without prior exposure to humic acid.
381
Comparison of energy consumption: For the single-cell DC electrolysis configuration,
382
the cathodic current declined rapidly at first and then leveled out (Figure 2C). The
383
initial rapid decline was likely due to the initial electrode polarization driven by 18
ACS Paragon Plus Environment
Page 18 of 34
Page 19 of 34
Environmental Science & Technology
384
reduction of functional groups on the carbon surface. This behavior was observed with
385
or without a target contaminant (e.g., fipronil), and has been observed in previous
386
studies of carbon-based electrodes.24 The current profiles and the currents after the first
387
1 h of treatment were fairly similar for the three electrode spacings because the current
388
delivered to the cathode is controlled by the constant applied potential (-1 V vs. S.H.E.)
389
and the prevalence of reducible groups on the cathode, which were similar for the three
390
electrode spacings. However, the decline in current was somewhat slower for the
391
closest spacing of electrodes, concurring with the somewhat greater yield of chloride
392
within the first ~15 min. The higher current likely reflects the decrease in solution
393
resistance with closer spacing of the electrodes, as discussed below.
394
The full-cell voltage also declined over time, but more slowly for the widest
395
spacing of the electrodes (Figure 2B). The full-cell voltage (Vcell) is provided by
396
equation 2.25
397
Vୡୣ୪୪ = V + ηୟ + ηୡ + iR
[2]
398
where V0 (V vs. S.H.E.) is the equilibrium potential for the reduction reaction, and ηୟ
399
and ηୡ are the overpotentials on the anode and cathode, respectively. The
400
overpotentials are determined by the nature of the electrode and electrolytes. In these
401
experiments, V0, ηa and ηc were the same for the three different electrode spacings. The
402
last term iR represents the solution resistance, where i is the current (A) and R is the
403
ohmic resistance (Ω) of the solution. The magnitude of ohmic resistance largely
404
depends on the electrolyte concentration and the geometry of the electrolysis cell
19
ACS Paragon Plus Environment
Environmental Science & Technology
405
406
(equation 3):
R = ρ
[3]
407
where l is the distance between electrodes (cm), A is the planar area of one of the
408
parallel electrodes (cm2), and ρ is the ionic resistivity (Ω cm) of the electrolytes, which
409
depends on the electrolyte type and concentration. Since the fipronil reaction,
410
electrodes and electrolyte solution were the same for the three electrode spacings, the
411
full-cell voltage should depend predominantly on the current and the spacing between
412
the electrodes via the solution resistance term. By decreasing the spacing between the
413
anode and cathode, and increasing the interfacial area of the electrodes, the
414
parallel-plate configuration was hypothesized to decrease the ohmic resistance
415
compared to the dual-cell configuration. The slower decline in voltage for the widest
416
electrode spacing (Figure 2B) indicates that the increase in ohmic resistance driven by
417
the wider spacing outstrips the decrease in current.
418
Figure 2D provides the full-cell resistance, calculated by dividing the full-cell
419
voltage by the current. The resistance increased initially and then leveled out after
420
~0.5 h, indicating that the current declined to a greater extent than the full-cell voltage.
421
The average resistance measured between 0.5-2 h (2.7-7.7 Ω) was positively related to
422
the electrode spacing (Figure 2E). The total energy consumption (kWh), calculated by
423
integrating the power (P = IV) over the first 2 h, increased with distance between the
424
electrodes from 2.7 x 10-4 kWh to 7.7 x 10-4 kWh (Figure 2F).
425
For the dual-cell configuration with the GAC/carbon cloth electrode, the average 20
ACS Paragon Plus Environment
Page 20 of 34
Page 21 of 34
Environmental Science & Technology
426
resistance measured over 0.5-2 h was 248 Ω, more than an order of magnitude higher
427
than for the single-cell parallel-plate configuration. The total energy consumption for
428
the dual-cell configuration over the first 2 h was 5.3 x 10-4 kWh, calculated using the
429
same procedure described for the single-cell DC configuration. Although the full-cell
430
resistance of the dual-cell configuration was significantly higher, its current was lower,
431
resulting in a similar energy consumption compared to the single-cell DC electrolysis.
432
For AC electrolysis (-1 V to +1 V vs. S.H.E.) at 0.0125 Hz with a 2.2 cm electrode
433
spacing, Figure S6 provides current and power profiles, as measured by the potentiostat.
434
Given the fluctuation in the applied voltage, it was not feasible to use a multimeter to
435
measure an average full-cell voltage or resistance. The energy consumed over 4 h of
436
AC electrolysis was 2.12×10-4 kWh, 52% lower than the energy consumption for 2 h of
437
DC electrolysis using the same electrode spacing. At this frequency, 93% removal of
438
fipronil was observed over 4 h, such that the electrical energy required per log order of
439
fipronil removal (i.e., the EEO) was 1.84×10-4 kWh. The lower energy consumption
440
for AC electrolysis likely reflects the fact that the time during which the applied voltage
441
was held at the extreme values (i.e., -1 V or +1 V) was short.
442
Environmental implications: While electrochemical treatment of contaminants has
443
been evaluated at laboratory-scale, there are very few instances where these
444
technologies are applied at full-scale.21 Two factors hindering implementation of
445
electrochemical technologies at full-scale include drawbacks associated with electrode
446
materials and the complexity of electrochemical treatment configurations. For
447
treatment of stormwater flows, residence times of water within the electrochemical 21
ACS Paragon Plus Environment
Environmental Science & Technology
448
reactor likely would be ~10 min. Due to their poor sorptive properties, electrochemical
449
treatment of organic contaminants in stormwater using the metal-based electrodes
450
favored in many laboratory-scale studies would require that contaminant degradation
451
occur during these short hydraulic residence times, which may not be possible. For
452
certain organic contaminants that can sorb to GAC, sorption of the organic
453
contaminants to the GAC-based electrodes may be feasible over these short hydraulic
454
residence times. Degradation of the sorbed fipronil could then occur over longer
455
timescales that are more feasible.
456
contaminants and electrode regeneration need be only intermittent; daily regeneration
457
could be powered by solar panels, an attractive feature for remote stormwater locations.
458
Although it is difficult to compare the energy requirements between GAC-based
459
electrodes and conventional metal-based electrodes due to differences in electrode
460
configurations, the longer timescales permitted for degradation of sorbed contaminants
461
by GAC-based electrodes renders treatment of flowing stormwater feasible.
Indeed, degradation of accumulated organic
462
Laboratory-scale electrochemical treatment configurations, such as our dual-cell
463
system with an intervening ion exchange membrane and platinum wire anode, are
464
difficult to scale up. We envision a full-scale system capable of treating a continuous
465
stormwater flow to consist of a series of parallel plates of GAC-based electrodes
466
operated in an AC configuration without an intervening ion exchange membrane
467
(Figure S1D). Organic contaminants in the stormwater would sorb to the GAC-based
468
electrodes during passage of the stormwater through the electrochemical treatment unit.
469
Application of AC electrolysis, potentially intermittently, would achieve reductive 22
ACS Paragon Plus Environment
Page 22 of 34
Page 23 of 34
Environmental Science & Technology
470
dehalogenation of sorbed contaminants, permitting long-term operation of the system.
471
Formation of free chlorine, chlorate, and perchlorate by oxidation of chloride has
472
been observed in previous electrochemical studies involving DC electrolysis with
473
metal-based electrodes.26 An ion exchange membrane would prevent the formation of
474
these undesirable byproducts, but would require the development of a series of
475
alternating cathode and anode chambers, with a separate water supply to the anode
476
chambers. Elimination of the ion exchange membrane would simplify the configuration
477
by permitting the water stream to flow in channels between the anodes and cathodes.
478
Indeed, one of the few instances where full-scale electrochemical treatment is applied
479
involves the in situ generation of free chlorine by oxidation of chloride at the anode,
480
and so does not require the ion exchange membrane. Most laboratory-scale studies of
481
electrochemical treatment focus on DC electrolysis. Our results indicate that free
482
chlorine, chlorate and perchlorate generation can be avoided even without an ion
483
exchange membrane by using AC electrolysis. The frequency was low enough to
484
enable the reductive dehalogenation of sorbed pesticides, but high enough to avoid the
485
transport and oxidation of halides at the anode. AC electrolysis also avoided oxidative
486
degradation of the GAC-based electrode and reduced the energy consumption. It is
487
conceivable that the alternating potential could achieve reductive dehalogenation and
488
then oxidative mineralization of the carbon backbone of sorbed contaminants, but
489
further research would be needed to verify the fate of specific contaminants.
490
Many additional factors need to be evaluated to enable the development of a
491
pilot-scale electrochemical treatment system for stormwater runoff. Some of the most 23
ACS Paragon Plus Environment
Environmental Science & Technology
492
important include the following. First, the experiments with Lake Lagunita water
493
suggest that sorption of fipronil occurs over long time-scales (~4 h). However, these
494
experiments involved the submergence of closely-spaced parallel plate electrodes
495
within a larger (500 mL) chamber. In ongoing research, we are developing a
496
flow-through reactor configuration in which the water would pass only within narrow
497
channels between the electrodes. This configuration would enable a more accurate
498
evaluation of the ability of the GAC-based electrodes to sorb organic contaminants
499
within hydraulic residence times relevant to stormwater treatment units. The design of
500
such a system will need to consider the effects of an applied potential on the sorption of
501
contaminants, particularly charged contaminants such as fipronil (which features a
502
primary amine functional group), and the potential for clogging by particles in
503
stormwater. Second, research is needed regarding alternative current distributors,
504
including metals, that can bind activated carbon particles but maintain a homogeneous
505
potential over larger electrodes.
506
non-homogenous distribution of potential at larger scales. Third, our AC electrolysis
507
experiments with Lake Lagunita water did not indicate significant degradation of
508
electrode performance over 5 cycles of sorption and electrolysis. However, to be
509
cost-effective, pilot-scale research is needed to demonstrate the performance of this
510
system over many more cycles. Issues of concern include abrasion of GAC particles
511
and reduced performance resulting from sorption of natural organic matter.
512
Acknowledgements: This research was supported by funding from the California
513
Department of Pesticide Regulation under Contract 15-C0087. We thank Dr. Susan
Carbon cloth is expensive, and may exhibit
24
ACS Paragon Plus Environment
Page 24 of 34
Page 25 of 34
Environmental Science & Technology
514
Richardson and Joshua Allen of the University of South Carolina Department of
515
Chemistry for help with product identification.
516
SUPPORTING INFORMATION AVAILABLE
517
The Supporting Information is available free of charge on the ACS
518
Publications website at DOI:
519
Alternating current electrolysis current and power profiles.
520
References
521
1.
522
http://npic.orst.edu/factsheets/fiptech.pdf
523
2.
524
S.; Malaspina, O., Effects of Sublethal Dose of Fipronil on Neuron Metabolic Activity
525
of Africanized Honeybees. Arch Environ Con Tox 2013, 64, (3), 456-466.
526
3.
527
insecticides to the Sacramento-San Joaquin Delta of California. Environ. Sci. Technol.
528
2010, 44, 1833-1840.
529
4.
530
desulfinylation with retention of neurotoxicity. P Natl Acad Sci USA 1996, 93, (23),
531
12764-12767.
532
5.
533
Fipronil Insecticide and Its Sulfone Metabolite and Desulfinyl Photoproduct. Chem.
534
Res, Toxicol. 1998, 11, (12), 1529-1535.
535
6.
536
Neurotoxicity resulting from coexposure to pyridostigmine bromide, DEET, and
537
permethrin: Implications of Gulf War chemical exposures. J Toxicol Env Health 1996,
538
48, (1), 35-56.
539
7.
540
aspects of reproduction in Atlantic salmon (Salmo salar L.). Aquatic Toxicology 2001,
National Pesticide Information Center Fipronil technical fact sheet.
Roat, T. C.; Carvalho, S. M.; Nocelli, R. C. F.; Silva-Zacarin, E. C. M.; Palma, M.
Weston, D.P.; Lydy, M.J. Urban and agricultural sources of pyrethroid
Hainzl, D.; Casida, J. E., Fipronil insecticide: Novel photochemical
Hainzl, D.; Cole, L. M.; Casida, J. E., Mechanisms for Selective Toxicity of
AbouDonia, M. B.; Wilmarth, K. R.; Jensen, K. F.; Oehme, F. W.; Kurt, T. L.,
Moore, A.; Waring, C. P., The effects of a synthetic pyrethroid pesticide on some 25
ACS Paragon Plus Environment
Environmental Science & Technology
541
52, (1), 1-12.
542
8.
543
synthetic pyrethroid insecticide cis-bifenthrin. J. Environ. Sci. 2009, 21, (12),
544
1710-1715.
545
9.
546
of neonicotinoids and fipronil on vertebrate wildlife. Environ Sci Pollut R 2015, 22,
547
(1), 103-118.
548
10. Tingle, C. C. D.; Rother, J. A.; Dewhurst, C. F.; Lauer, S.; King, W. J., Fipronil:
549
Environmental fate, ecotoxicology, and human health concerns. Rev Environ Contam
550
Toxicol. 2003, 176, 1-66.
551
11. Australian Pesticides and Veterinary Medicines Authority. Fipronil Part 1. Safety
552
of Fipronil in Dogs and Cats: a review of literature. https://apvma.gov.au/node/15191
553
(retrieved October 7, 2017).
554
12. Jones, W. J.; Mazur, C. S.; Kenneke, J. F.; Garrison, A. W., Enantioselective
555
microbial transformation of the phenylpyrazole insecticide fipronil in anoxic
556
sediments. Environ. Sci. Technol. 2007, 41, (24), 8301-8307.
557
13. Konwick, B. J.; Garrison, A. W.; Black, M. C.; Avants, J. K.; Fisk, A. T.,
558
Bioaccumulation, biotransformation, and metabolite formation of fipronil and chiral
559
legacy pesticides in rainbow trout. Environ. Sci. Technol. 2006, 40, (9), 2930-2936.
560
14. Zhu, G. N.; Wu, H. M.; Guo, J. F.; Kimaro, F. M. E., Microbial degradation of
561
fipronil in clay loam soil. Water Air Soil Poll 2004, 153, (1-4), 35-44.
562
15. Lin, K.; Haver, D.; Oki, L.; Gan, J., Transformation and sorption of fipronil in
563
urban stream sediments. J Agr Food Chem 2008, 56, (18), 8594-8600.
564
16. Zhao, X. L.; Yeh, J. Z.; Salgado, V. L.; Narahashi, T., Sulfone metabolite of
565
fipronil blocks gamma-aminobutyric acid- and glutamate-activated chloride channels
566
in mammalian and insect neurons. J Pharmacol Exp Ther 2005, 314, (1), 363-373.
567
17. Budd, R.; Ensminger, M.; Wang, D.; Goh, K. S., Monitoring Fipronil and
568
Degradates in California Surface Waters, 2008–2013. J Environ Qual 2015, 44, (4),
569
1233-1240.
570
18. Li, Y.; Kemper, J. M.; Datuin, G.; Akey, A.; Mitch, W. A.; Luthy, R. G., Reductive
Wang, C.; Chen, F.; Zhang, Q.; Fang, Z., Chronic toxicity and cytotoxicity of
Gibbons, D.; Morrissey, C.; Mineau, P., A review of the direct and indirect effects
26
ACS Paragon Plus Environment
Page 26 of 34
Page 27 of 34
Environmental Science & Technology
571
dehalogenation of disinfection byproducts by an activated carbon-based electrode
572
system. Water Res 2016, 98, 354-362.
573
19. Yang, Y.; Li, Y.; Walse, S. S.; Mitch, W. A., Destruction of Methyl Bromide
574
Sorbed to Activated Carbon by Thiosulfate or Electrolysis. Environ. Sci. Technol.
575
2015, 49, (7), 4515-4521.
576
20. Li, Y.; Liu, C.; Cui, Y.; Walse, S. S.; Olver, R.; Zilberman, D.; Mitch, W. A.,
577
Development of an Activated Carbon-Based Electrode for the Capture and Rapid
578
Electrolytic Reductive Debromination of Methyl Bromide from Postharvest
579
Fumigations. Environ. Sci. Technol. 2016, 50, (20), 11200-11208.
580
21. Radjenovic, J.; Sedlak, D. L., Challenges and Opportunities for Electrochemical
581
Processes as Next-Generation Technologies for the Treatment of Contaminated Water.
582
Environ. Sci. Technol. 2015, 49, (19), 11292-11302.
583
22. Xie, X.; Ye, M.; Liu, C.; Hsu, P.-C.; Criddle, C. S.; Cui, Y., Use of low cost and
584
easily regenerated Prussian Blue cathodes for efficient electrical energy recovery in a
585
microbial battery. Energy & Environmental Science 2015, 8, (2), 546-551.
586
23. Clesceri, L. S.; Greenberg, A. E.; Eaton, A. D., Standard Methods for the
587
Examination of Water and Wastewater, 20th ed. American Public Health Association,
588
American Water Works Association, Water Environment Federation: Washington, DC,
589
1998.
590
24. Sun. M.; Reible, D.D.; Lowry, G.V.; Gregory, K.B. Effect of applied voltage,
591
initial concentration, and natural organic matter on sequential reduction/oxidation of
592
nitrobenzene by graphite electrodes. Environ. Sci. Technol. 2012, 46, 6174-6181.
593
25. Hamann, C. H.; Hamnett, A.; Vielstich, W., Electrochemistry. Wiley-VCH:
594
Weinheim, Germany, 2007.
595
26. Jasper, J.T.; Yang, Y.; Hoffmann, M.R. Toxic byproduct formation during
596
electrochemical treatment of latrine wastewater. Environ. Sci. Technol. 2017, 51,
597
7111-7119.
598
27
ACS Paragon Plus Environment
Environmental Science & Technology
Page 28 of 34
599
Figure 1. Dual cell electrolysis experiments. A) Electrolytic degradation of 0.34 µmol
600
fipronil by DC electrolysis (-1 V vs. S.H.E.) using the GAC/graphite electrode after 15
601
h treatment. B) Degradation by DC electrolysis (-1 V vs. S.H.E.) using the GAC/carbon
602
cloth electrode of 3.2 µmol fipronil, formation of fipronil sulfide and C) chloride
603
release. Dechlorination percent was calculated by dividing the mass of chloride in the
604
aqueous phase by the initial mass of chlorine in the fipronil. D) Electrolytic degradation
605
after 2 h of 150 µg each of a mixture of fipronil, bifenthrin and permethrin using the
606
GAC/carbon cloth electrode as a function of applied potential vs. S.H.E. Error bars
607
represent the range of experimental duplicates. Some errors are smaller than the
608
symbols. A)
B)
% 0 0 6
Fipronil Fipronil sulfide
% 0 2
% 0 0 1
C/C0
% 0 3
% 0 0 2
C/C0
% 0 0 1
% 0 0 4
Aqueous Fipronil Sorbed Fipronil ClFFipronil sulfide
% 0 1
% 0 5
% 0
% 0
5 1
2
Control
1
0
Initial
Electrolysis
Time (h)
C)
D) % 0 0 1
Fipronil % 0 6
4
Permethrin
15
Applied potential
Time (h)
609 610 611
28
ACS Paragon Plus Environment
V 2 . 0 -
V 4 . 0 -
V 6 . 0 -
V 8 . 0 -
10
C/C0 % 0
5
% 0 2
% 0
0 0
% 0 4
% 0 5
Dechlorination
2
[Cl-] (µM)
Bifenthrin
Page 29 of 34
Environmental Science & Technology
612
Figure 2. Single-cell DC electrolysis (-1 V vs. S.H.E.) of 500 µg (1.15 µmol) fipronil at
613
pH 7.0 with 100 mM phosphate buffer. A) Chloride yield (dechlorination is calculated
614
by dividing the aqueous mass of chloride by the initial mass of chlorine in the fipronil),
615
B) full-cell voltage, C) current, D) full-cell resistance, E) average resistance (0.5 – 2 h)
616
and F) energy consumption for different electrode spacings. Error bars represent the
617
range of experimental duplicates. Some errors are smaller than the symbols.
29
ACS Paragon Plus Environment
Environmental Science & Technology
618 619
30
ACS Paragon Plus Environment
Page 30 of 34
Page 31 of 34
Environmental Science & Technology
620
Figure 3. Free chlorine formation during single-cell electrolysis using direct current
621
(-1 V vs. S.H.E.) and alternating current (-1 V to +1 V vs. S.H.E. at 0.0025, 0.0125
622
and 0.025 Hz) for a 1 mM chloride solution. Error bars represent the range of
623
experimental duplicates. Some errors are smaller than the symbols.
624 625 626 627
31
ACS Paragon Plus Environment
Environmental Science & Technology
628
Figure 4. Chloride yield during AC electrolysis of 1 mg (2.3 µmol) fipronil using a
629
triangular waveform from -1 V to +1 V vs. S.H.E. at different scan rates at pH 7.0 using
630
100 mM phosphate buffer. Dechlorination is calculated by dividing the aqueous mass
631
of chloride by the initial mass of chlorine in the fipronil. Error bars represent the range
632
of experimental duplicates. Some errors are smaller than the symbols. B) 1 mg of
633
permethrin and bifenthrin using a triangular waveform from -1 V to +1 V vs. S.H.E. at
634
0.025 Hz.
635 636
32
ACS Paragon Plus Environment
Page 32 of 34
Page 33 of 34
Environmental Science & Technology
637
Figure 5. Aqueous fipronil concentration during the AC electrolysis of Lake Lagunita
638
water spiked with 1 mg (2.3 µmol) fipronil using a triangular waveform from -1 V to +1
639
V vs. S.H.E. at 0.0125 Hz during 5 cycles of 4 h sorption and 4 h AC electrolysis each.
640
Error bars represent the range of experimental duplicates. Some errors are smaller than
641
the symbols. % 0 0 1 % 0 6
AC applied AC applied
AC applied
AC applied
% 0 4
Caq/C0
% 0 8
AC applied
% 0 2 % 0
644 645
33
ACS Paragon Plus Environment
0 4
643
0 3
0 2
0 1
0
Time (h)
642
Environmental Science & Technology
646
TOC Art
647 648 649
34
ACS Paragon Plus Environment