Electrochemical Ion Exchange Regeneration and Fluidized Bed Crystallization for Zero Liquid Discharge Water Softening Yingying Chen, Jake R Davis, Chi Huynh Nguyen, James Claude Baygents, and James Farrell Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.5b05606 • Publication Date (Web): 10 May 2016 Downloaded from http://pubs.acs.org on May 10, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 27
Environmental Science & Technology
1
Electrochemical Ion Exchange Regeneration and Fluidized Bed
2
Crystallization for Zero Liquid Discharge Water Softening
3 4 5 6 7 8 9
Yingying Chen, Jake R. Davis, Chi H. Nguyen, James C. Baygents and James Farrell*
10
Department of Chemical and Environmental Engineering
11
University of Arizona, Tucson, AZ 85721
12 13 14 15 16 17 18 19 20 21 22
Keywords: bipolar membrane electrodialysis, ion exchange regeneration, water softening, fluidized bed crystallization, zero liquid discharge, brine disposal, Tokuyama BP1, Fumasep FBM
23 24 25 26
*corresponding author:
[email protected]; 520 940-0487
27 28
ACS Paragon Plus Environment
1
Environmental Science & Technology
29
Page 2 of 27
Abstract
30
This research investigated the use of an electrochemical system for regenerating ion
31
exchange media and for promoting crystallization of hardness minerals in a fluidized bed
32
crystallization reactor (FBCR). The closed-loop process eliminates the creation of waste brine
33
solutions that are normally produced when regenerating ion exchange media.
34
membrane electrodialysis stack was used to generate acids and bases from 100 mM salt solutions.
35
The acid was used to regenerate weak acid cation (WAC) ion exchange media used for water
36
softening. The base solutions were used to absorb CO2 gas, and to provide a source of alkalinity
37
for removing noncarbonate hardness by WAC media operated in H+ form. The base solutions
38
were also used to promote crystallization of CaCO3 and Mg(OH)2 in a FBCR. The overall
39
process removes hardness ions from the water being softened and replaces them with H+ ions,
40
slightly decreasing the pH value of the softened water. The current utilization efficiency for acid
41
and base production was ~75% over the operational range of interest, and the energy costs for
42
producing acids and bases were an order of magnitude lower than the costs for purchasing acid
43
and base in bulk quantities. Ion balances indicate that the closed-loop system will accumulate
44
SO42-, Cl- and alkali metal ions. Acid and base balances indicate that for a typical water, small
45
amounts of base will be accumulated.
A bipolar
46
ACS Paragon Plus Environment
2
Page 3 of 27
47
Environmental Science & Technology
Introduction
48
Many industrial and domestic uses of water require water softening in order to avoid scale
49
formation on heat transfer surfaces. Examples of this include, water used in boilers for electric
50
power generation and water used in evaporative cooling systems. The most common method of
51
industrial and domestic water softening is ion exchange. The regeneration of ion exchange
52
media produces large quantities of brine. A single regeneration cycle produces several cubic
53
meters of brine solution per cubic meter of ion exchange media.1 Brine disposal methods include
54
metered discharge to the sewer system, ocean discharge, evaporation ponds and thermal
55
crystallization. 2 Metered discharge to sewer systems can result in toxicity to biomass and
56
inhibition of settling in clarifiers used in secondary wastewater treatment.2 Inland areas do not
57
have the option of ocean discharge, and thermal crystallization is very expensive. Evaporation
58
ponds are also problematic in that they require large land areas and become nuisances due to
59
algal growth, attraction of brine flies, and anaerobic microbial growth that results in production
60
of a variety of foul smelling and toxic gases (e.g., H2S).
61
In most cases, ion exchange brines are sent to the sanitary sewer system for disposal. This
62
practice contributes to increasing salinification of public water supplies. The problem of water
63
salinification is particularly acute in the desert southwest of the United States. For example, the
64
water supplying the Phoenix, Arizona metropolitan area brings in 1.46 million tons of salt each
65
year into the local watershed. Only 0.36 million tons of salt flow out of the watershed each
66
year.3 This leaves a net of 1.1 million tons of salt accumulation per year, 40% of which ends up
67
in the groundwater and 22% in the vadose zone.3 This accumulation does not even include salts
68
added to the water as a result of water softening, which is responsible for an estimated 26% of
69
the total salt content of wastewater discharged into sanitary sewer systems.3
ACS Paragon Plus Environment
The high
3
Environmental Science & Technology
Page 4 of 27
70
contribution of water softening to water salinification has prompted many communities to ban
71
water softeners that use salts or acids for regeneration.4
72
Bipolar Membrane Electrodialysis
73
The problems and costs associated with brine disposal can be eliminated if the acids and
74
bases used for ion exchange media regeneration could be reused in a zero liquid discharge,
75
closed-loop process. Bipolar membrane electrodialysis (BMED) has been used to produce acids
76
and bases from concentrated salt solutions, from reverse osmosis concentrates, and from brine
77
solutions resulting from spent acids and bases.5,6,7,8 The repeating unit cell in a BMED stack
78
consists of an anion exchange membrane, a bipolar membrane, and a cation exchange membrane,
79
as illustrated in Figure S1 in the Supporting Information. BMED stacks can contain up to 300 of
80
these unit cells. Bipolar membranes consist of three layers: a strong acid cation exchange layer
81
(CEL), a strong base anion exchange layer (AEL), and a very thin intermediate layer containing
82
a catalyst. The catalyst layer promotes water dissociation into H+ and OH- ions via the second
83
Wien effect.9 Application of a reverse biased electric field across the bipolar membrane results
84
in electromigration of H+ ions towards the cathode and OH- ion towards the anode. An anion
85
exchange membrane (AEM) traps acid in the acid chamber, as illustrated in Figure S1. Likewise,
86
a cation exchange membrane (CEM) traps OH- ions created by water splitting in the base
87
chamber. Electromigration of anions from the feed solution through the AEM into the acid
88
chambers maintains electroneutrality of the acid.
89
through the CEM maintains the charge balance in the base chamber.
90
Fluidized Bed Crystallization
Cation migration from the feed solution
91
Fluidized bed crystallization reactors (FBCR) have been used to promote crystallization of
92
minerals on seed crystals or sand grains suspended in an upflow reactor.10,11,12 In water softening
ACS Paragon Plus Environment
4
Page 5 of 27
Environmental Science & Technology
93
applications this process is known as pellet softening, and garnet sand is often used as the seed
94
material to promote heterogeneous crystallization. In pellet softening, water containing hardness
95
ions are fed into a FBCR along with a stream of Na2CO3, or if the water has sufficient
96
bicarbonate alkalinity, a stream of NaOH.
97
heterogeneous crystallization of hardness minerals in the reactor, forming pellets. Once the
98
crystals grow to ~2-5 mm in diameter, the pellets are flushed out of the bottom of the reactor.
99
Due to the large size of the pellets, they are easily dewatered via gravity drainage. Pellet
100
softening has been used in the Netherlands for softening at municipal water treatment plants
101
since the early 1980s.12 Currently, pellet softening is used at 25 water treatment plants in Europe,
102
Asia and Australia, but at only three locations in the United States.13
The seed material and high pH promote
103
Two issues have prevented wide adoption of FBCR softening. These are: 1) the need to
104
add pH adjusting chemicals, such as NaOH or Na2CO3, and 2) the need for tall reactors, up to 12
105
m in height.14 The addition of pH adjusting chemicals is costly and adds to the TDS load of the
106
water. Although the softening processes proceeds quite rapidly, with 90% of the hardness
107
removal occurring after about 30 seconds of contact time, tall reactors are needed in order to
108
ensure sufficient hydraulic detention time that the water exiting the top of the reactor is only
109
marginally supersaturated with respect to calcite.11,15 If the saturation index of the water exiting
110
the top of the reactor is too high, acid must be added to reduce the degree of supersaturation.
111
Acid addition is undesirable because of its cost and the associated increase in treated water
112
salinity. For these reasons, acid is not generally added in FBCR softening, and tall reactors are
113
employed.10 Even with reactors as tall as 5 m, the level of hardness removal is typically
114
~50%.12,14,16
ACS Paragon Plus Environment
5
Environmental Science & Technology
Page 6 of 27
115
The goal of this research was to investigate the feasibility of regenerating ion exchange
116
media in a closed-loop system that produces no liquid waste products. A BMED stack was used
117
to generate acid and base streams using 100 mM Na2SO4 or NaCl solutions. The acid and base
118
were used to regenerate ion exchange media. Base generated by the BMED stack was also used
119
to produce a high pH stream containing dissolved carbonate ions.
120
crystallize CaCO3 and Mg(OH)2 minerals on garnet sand grains. Ion balances and acid/base
121
balances indicate that the process is technically feasible. Electrical energy costs for generating
122
the acids and bases were low compared to the costs for purchasing acid and base in bulk
123
quantities.
124
Material and Methods
125
Acid and Base Generation
A FBCR was used to
126
Acid and base solutions were generated using feed solutions consisting of 100 mM Na2SO4
127
or 100 mM NaCl. Solutions were prepared in 18 MΩ cm ultrapure water (UPW) using ACS
128
grade reagents obtained from Fisher Scientific.
129
continuously stirred 55-gallon high density polyethylene (HDPE) drum. The feed solutions were
130
fed into a BMED stack containing 8 unit cells, each consisting of a bipolar membrane, anion
131
exchange membrane and cation exchange membrane. The BMED stack was housed in a PC-Cell
132
EDQ380 electrodialysis unit (PC-Cell GmbH, Heusweiler, Germany), and had 380 cm2 of active
133
area per membrane. Polypropylene mesh spacers with built-in silicone gasketing were placed
134
between each membrane pair forming 195 mm x 195 mm x 0.5 mm flow channels. The spacing
135
between the electrodes and the cation exchange membranes terminating each end of the stack
136
was approximately 2 mm. A 200 mm by 200 mm expanded stainless steel mesh was used as the
137
cathode. The anode was the same size and consisted of an expanded titanium mesh with a
The feed solutions were contained in a
ACS Paragon Plus Environment
6
Page 7 of 27
Environmental Science & Technology
138
platinum-iridium oxide coating. The AEM (Neosepta ACM) was 0.17 mm thick and had an
139
exchange capacity of 1.4-1.7 mequiv g-1. The CEM (Neosepta CMX) was 0.18 mm thick and
140
had an exchange capacity of 1.5-1.8 mequiv g-1.
141
Fumasep FBM, PEEK reinforced membrane and a Neosepta BM-1.
Two bipolar membranes were tested, a
142
Two centrifugal pumps placed in series were used to feed the salt solutions to the BMED
143
stack. A volumetric flow rate of 0.5 L min-1 was used for the diluate and flow rates of 0.25 L
144
min-1 were used for the acid and base streams. The electrode rinse solution passed through both
145
anode and cathode chambers at 1.5 L min-1, and was recirculated to the feed drum after passing
146
through a custom degasser and a 10-inch long block carbon filter. The block carbon filter served
147
to remove hypochlorite or peroxodisulfate formed via oxidation of Cl- or SO42- at the anode. In
148
practice, the electrode wash solutions are normally in a separate loop using a NaOH electrolyte
149
that avoids hypochlorite or peroxodisulfate production. The use of the same electrolyte in all cell
150
compartments was done to simplify the experimental setup. The BMED cell was operated
151
galvanostatically using a Xantrex XRT 40-21 power supply.
152
Fluidized Bed Crystallization Reactor
153
The FBCR reactor consisted of a 280 cm tall by 6.35 cm diameter clear PVC tubing
154
containing a 115 cm long bed of 40-60 mesh garnet sand.
155
heterogeneous nucleation sites for hardness mineral crystallization. During the crystallization
156
experiments, water was recirculated through the reactor at a flow rate of 0.46 L min-1 using a
157
peristaltic pump, as illustrated in Figure 1. This resulted in fluidization of the bed and expansion
158
by 15-20%.
159
hardness ions or carbonate ions into the base of the reactor, each at flow rate of 0.25 L min-1.
The garnet sand served as
Crystallization experiments were performed by feeding solutions containing
ACS Paragon Plus Environment
7
Environmental Science & Technology
Page 8 of 27
160
Solutions exiting the FBCR were first passed through a 6.35 cm diameter by 25 cm long
161
Doulton ceramic microfilter contained in standard filter housing. Effluent from the filter was
162
passed through the weak acid cation (WAC) ion exchange media in H+ form. This served to
163
remove residual hardness ions, lower the pH of the effluent solution to ~5.5, and to convert
164
CO32- and HCO3- ions into H2CO3. A second membrane contactor (membrane contactor #2) was
165
operated as a liquid-liquid contactor with the effluent from the FBCR passing through the tube
166
side. Base solutions with pH values ranging from 11 to 12.5 were passed through the lumen side
167
of the contactor. Dissolved CO2 gas from solutions exiting WAC #3 were absorbed by the high
168
pH solution. This process was used to reduce the carbonate content of the water that was cycled
169
back into feed solution for the BMED stack.
170
171 172 173 174 175 176
Figure 1. Schematic diagram of closed-loop system for regenerating ion exchange media and crystallizing hardness minerals in a fluidized bed crystallization reactor (FBCR). A modified version of this figure that contains the composition of each stream is included as Figure S2 in the Supporting Information. Recirculation loops for the BMED cell and FBCR are noted with bold lines.
177 178
Regeneration Experiments
ACS Paragon Plus Environment
8
Page 9 of 27
Environmental Science & Technology
179
Weak acid cation ion exchange media (Purolite C104) loaded with hardness ions was
180
regenerated at a flow rate of 0.125 L min-1 using acid produced by the BMED stack. The WAC
181
media was contained in 6.35 cm diameter by 25 cm long cartridges in standard filter housing.
182
Effluent from the WAC cartridges was fed into the FBCR, as illustrated in Figure 1. A lead-lag
183
configuration was used to minimize acid addition to the FBCR. WAC#3 can also be regenerated
184
in a lead-lag process.
185
Base produced by the BMED stack was used to absorb CO2 gas and to regenerate weak
186
base anion (WBA) ion exchange media. A fraction of the base solution from the BMED stack
187
was passed through the tube side of a Liqui-cel model G420 hollow fiber membrane contactor
188
(Membrane Contactor #1), as illustrated in Figure 1. The contactor was 6.7 cm in diameter by 28
189
cm long and contained polypropylene fibers with a total external surface area of 1.4 m2. The
190
membrane contactor was operated as a gas-liquid contactor and had its lumen side connected to a
191
tank of CO2 gas. The effluent fitting on the lumen side was capped and the CO2 pressure inside
192
the contactor was fixed at 104±4 kPa. Effluent solution from the gas-liquid contactor was then
193
used to regenerate WBA media into HCO3- form. Effluent from the WBA media was combined
194
with a base stream that bypassed the contactor. A series of 10 regeneration experiments were
195
performed to assess how the fraction of the base stream that was fed through the membrane
196
contactor affected the pH and carbonate content of the feed stream to the FBCR.
197
Water Softening
198
Water softening experiments were performed to determine ion balances between softening
199
and regeneration cycles.
200
synthetic tap water prepared in UPW with pH=7, containing: 6.4 meq/L Na+, 2.8 meq/L Ca2+,
201
1.66 meq/L Mg2+, 4.73 meq/L Cl-, 3.46 meq/L SO42-, 2.67 meq/L HCO3-, 0.002 meq/L CO32- and
The ion exchange media was loaded with hardness ions using a
ACS Paragon Plus Environment
9
Environmental Science & Technology
Page 10 of 27
202
0.53 mM H2CO3. This water composition contains the three most predominant cations and the
203
four most predominant anions.17 Other cations typically found in water, such as K+, Cu2+, and
204
Zn2+ are normally present at much lower concentrations, and are not considered here. The water
205
composition was selected to be representative of a very hard water with a level of noncarbonate
206
(permanent) hardness of 40%. This level of permanent hardness represents the high end of
207
values that may be found in real waters, which typically have noncarbonate hardness
208
concentrations that are 0 to 25% of the total hardness.18,19
209
Because the WAC media was operated in H+ form, a column of WBA media in the HCO3-
210
form was needed to provide additional bicarbonate to remove permanent hardness, as illustrated
211
in Figure S3 in the Supporting Information. The water softening system consisted of a column
212
of Purolite A103 WBA media loaded with sulfate and bicarbonate followed by a column of
213
Purolite C104 media operated in the H+ form. The WBA media had a manufacturer’s reported
214
exchange capacity of 1.6 eq/L and the WAC media had a capacity of 4.0 eq/L. Because of its
215
lower exchange capacity, the volume of WBA media (16.3 mL) was 2.5 times greater than the
216
volume of WAC media (6.5 mL). The media were packed in glass columns with diameters of 1
217
cm and were operated at flow rate of 0.7 mL/min, corresponding to an empty bed contact time of
218
9.4 minutes for the WAC column. Two Gilson FC204 fraction collectors were used to collect
219
effluent samples from each column every 60 minutes.
220
Solution Analyses
221
An Agilent model 5100 Synchronous vertical dual view inductively coupled plasma optical
222
emission spectrophotometer (ICP-OES) was used to determine the concentration of sodium,
223
calcium, magnesium, and sulfate in aqueous samples. Prior to analysis, samples were filtered
224
with 0.45 µm syringe filters and acidified using HCl. Alkalinity was measured colorimetrically
ACS Paragon Plus Environment
10
Page 11 of 27
Environmental Science & Technology
225
using the methyl orange method. 20 Solution pH values were measured using an AquaPro
226
9156APWP epoxy body pH probe and a Symphony model SB90M5 multimeter.
227
coefficients and saturation indices were calculated using the PHREEQC modeling package from
228
the U.S. Geological Survey.21 The PHREEQC package calculates activity coefficients using the
229
Davies or the extended WATEQ Debye-Huckel equation.22
230
Results and Discussion
Activity
231
The voltages required for acid and base generation were found to depend strongly on the
232
pH of the feed solution. Figure 2 shows the voltage drop per unit cell for an 8 cell BMED stack
233
using Tokuyama BP-1 bipolar membranes. Increasing pH values for the feed solution resulted in
234
increasing voltage drops per unit cell for both NaCl and Na2SO4 solutions. This effect has not
235
been previously reported in the BMED literature, and cannot be attributed to higher ionic
236
conductivities of the lower pH solutions. As shown in a previous publication, >90% of the
237
voltage drop for acid and base generation by this membrane in 100 mM salt solutions can be
238
attributed to the water splitting reaction inside the bipolar membrane.23 Thus, the feed solution
239
pH greatly affected the resistance for the water splitting reaction. Figure S4 in the Supporting
240
Information shows a similar effect for the Fumasep FBM membrane, which performed similarly
241
to the Tokuyama membrane for acid and base production. This effect of feed solution pH values
242
on the voltage requirement for water splitting cannot be explained by current theories on BMED.
243
This issue notwithstanding, to minimize the voltage for operating the cell, all regeneration
244
experiments were performed with a feed solution pH value of ~2.
245
Two different flow configurations were used to generate acids and bases. In the first
246
configuration, the same 100 mM salt solution was fed into all chambers of the BMED stack.
247
This configuration resulted in SO42- concentrations in the acid chamber of ~200 mM. When
ACS Paragon Plus Environment
11
Environmental Science & Technology
Page 12 of 27
248
sulfuric acid is used to regenerate ion exchange media, acid concentrations less than 200 mM are
249
recommended in order to avoid CaSO4 precipitation in the ion exchange media.24 To minimize
250
SO42- concentrations in the acid, a second configuration was investigated wherein the diluate
251
solution was fed into the acid and base chambers, as illustrated in Figure 1. This resulted in
252
SO42- levels in the acid that remained below 200 mM, even for the most concentrated acids that
253
were generated, as illustrated in Figure S5 in the Supporting information.
254
255 256 257 258
Figure 2. Voltage drop per unit cell (Δ Ψ ) as a function of current density (i) for an 8 cell stack of Tokuyama BP-1 membranes operated over a range in feed pH values using 100 mM Na2SO4 or NaCl solutions.
259 260
The acid or base concentration that could be generated was a function of both the
261
volumetric flow rate (Q), current density (i), area per BMED membrane (A), number of cells (n)
262
and current utilization ( ), as given by:
263
(1)
264
Figure 3 illustrates the current utilization for acid and base production, and the acid and base
265
concentrations, as a function of the current density. The acid concentrations were 20-25 mM
ACS Paragon Plus Environment
12
Page 13 of 27
Environmental Science & Technology
266
higher than the base concentrations due to the ~10 meq/L acid concentration in the feed solutions.
267
Current utilizations less than 1 resulted from acid and base leakage into the diluate compartments
268
of the cell. Lower current utilizations for acid production at current densities below 20 mA/cm2
269
can be attributed to greater acid than base leakage.
270
271 272 273 274
Figure 3. Current utilization ( ) as a function of current density for 8 cell stack of Fumasep BPM operated with a pH=2 feed solution of 100 mM Na2SO4 to all chambers. Also shown is the acid and base concentration as function of current density.
275 276 277
Ion Exchange Regeneration The WAC ion exchange media was regenerated using acid with pH values ranging from 0.8
278
to 1 in either 100 mM Na2SO4 or NaCl electrolyte solutions.
279
experiments were performed using the same ion exchange cartridges, but varying the fraction of
280
the base stream that was fed through membrane contactor #1.
281
carbonate content of the feed stream to the FBCR, and also affected the amount of Ca2+ removal,
282
as shown in Table S1 in the Supporting Information.
283
concentrations from the WAC media are shown in Figure S6 in the supporting information. By
ACS Paragon Plus Environment
A total of 10 regeneration
This affected the pH and
Typical effluent hardness ion
13
Environmental Science & Technology
Page 14 of 27
284
160 minutes elapsed, both Ca2+ and Mg2+ had been completely removed from WAC#1, while 99%
285
of the Mg2+ and 53% of the Ca2+ had been removed from WAC#2.
286
The regeneration stream was continuously fed into the FBCR along with a base stream
287
containing dissolved carbon dioxide. Adding CO2 converts alkalinity due to hydroxide ions into
288
carbonate alkalinity.
289
calculated from the change in hydroxide ion concentration ([OH-]), according to:
290 291
292
293
Therefore, the final H2CO3, HCO3- and CO32- concentrations can be
[OH-]i - [OH-]f = [HCO3-]f + 2[CO32-]f
(2)
and the mass action expressions for the reactions: {
}{
}
{
(3)
}
{
}{ {
} }
(4)
294 295
The activity coefficients and final concentrations of the carbonate species exiting the membrane
296
contactor are shown in Table S2 for a range of operating conditions using the NaCl electrolyte.
297
Figure 4 shows the concentrations of hardness ions in the FCBR for the regeneration data
298
shown in Figure S6. In this experiment, 33% of the base stream was passed through membrane
299
contactor #1 and the pH of the carbonate solution fed into the reactor was 12.5. The pH remains
300
stable because the rate of OH- ion addition is equal to the equivalents of acidic protons in HCO3-
301
and H2CO3 that are also entering the reactor. Bicarbonate and carbonic acid will react with OH-
302
to form water and CO32- ions. Throughout the course of the regeneration process, hardness ion
303
concentrations in the FBCR remained below 0.07 mM. Based on the aqueous concentrations in
304
the FBCR, 99.7% of the Ca2+ and 95.8% of the Mg2+ removed from the WAC crystallized in the
305
reactor. Effluent from the FBCR was passed through a ceramic microfilter and sampled. The
ACS Paragon Plus Environment
14
Page 15 of 27
Environmental Science & Technology
306
concentration of Ca2+ ions in the filtered effluent were 0.01 to 0.05 mM lower than in the reactor,
307
indicating the presence of CaCO3 crystals not associated with the garnet sand.
308
Mg2+ concentrations in the filtered effluent ranged from 0.03 to 0.07 mM lower than in the
309
reactor. This also suggests the presence of suspended Mg(OH)2 crystals smaller than the ~0.1
310
µm filter cutoff. The near zero Mg2+ concentrations in the filtered effluent suggest that the filter
311
was more effective at filtering suspended Mg(OH)2 crystals than suspended CaCO3 crystals.
The
312
313 314 315 316 317 318
Figure 4. Hardness ion concentrations in the FBCR operated at a pH of 12.5 using 100 mM Na2SO4 as the electrolyte. Also shown are hardness ion concentrations after passing through a ceramic microfilter and after passing through WAC #3 ion exchange media. Influent hardness ion concentrations ranged from 0.1 to 30 mM and are shown in Figure S6 in the Supporting Information.
319 320 321 322
Saturation indices, defined as: (
)
(5)
323
where: IAP is the ion activity product, and Ksp is the mineral solubility product, were calculated
324
for the conditions as the end of the regeneration experiment, as shown in Table S3 in the
325
Supporting Information. Based on the measured ion concentrations in the reactor, the saturation
326
indices for CaCO3 (SI=3.62) and Mg(OH)2 (SI=74.1) were significantly greater than 1,
ACS Paragon Plus Environment
15
Environmental Science & Technology
Page 16 of 27
327
indicating very high supersaturation of these species.
328
concentration measurements may have been impacted by crystals that were not removed by the
329
0.45 µm syringe filters. Thus, the hardness ion concentrations reported in Table S3 may be
330
greater than the dissolved hardness ion concentrations. Operating crystallization reactors at very
331
high saturation indices is undesirable and may promote homogeneous nucleation.10,11,12, 25 , 26
332
Furthermore, high levels of supersaturation are not needed to promote rapid crystallization.10,12,25
333
This indicates that the pH and total carbonate concentrations in the FBCR can likely be reduced
334
without adversely impacting its performance.
335
operating with NaCl electrolyte solutions, as shown in Figure S7 in the supporting information.
This suggests that hardness ion
Similar results were observed for systems
336
The filtered effluent from the FBCR was passed through WAC#3 media in the H+ form in
337
order to remove any residual hardness ions and to lower the pH of the effluent solution. This
338
process resulted in removal of less than 0.01 mM Ca2+ and less than 0.005 mM Mg2+. The small
339
amount of removal may be attributed to the low concentrations of hardness ions and the high
340
concentration of Na+ ions (200 mM), and to the presence of nanoparticulates passing through the
341
0.1 µm ceramic filter. Any nanoparticulates exiting WAC#3 would dissolve in the pH=2 feed
342
solution to the BMED stack. The low concentration of Mg2+ ions going back into the BMED
343
stack is not likely to cause a membrane fouling problem. For example, based on a base chamber
344
pH of 12.2, a Mg2+ concentration of 6.0 x 10-5 mM is required to reach saturation of Mg(OH)2 in
345
the base chamber. This is greater than the Mg2+ concentration of 4.5 x10-5 mM in WAC#3
346
effluent.
347
precipitation in the base chamber if carbonate concentrations in the feed stream are sufficiently
348
high. For example, based on a Ca2+ concentration in WAC#3 effluent of 6.8 x 10-3 mM, a CO32-
349
concentration greater than 0.67 mM in the base chamber would lead to supersaturation of CaCO3,
In contrast, the Ca2+ in the feed stream to the BMED stack may cause CaCO3
ACS Paragon Plus Environment
16
Page 17 of 27
Environmental Science & Technology
350
assuming the Ca2+ concentration in the feed is the same as that in the base chamber. This is a
351
reasonable assumption given that cation electromigration into the base chamber will be
352
dominated by Na+ ions, since they are at a concentration that is ~8000 times greater than Ca2+
353
ions in WAC#3 effluent.
354
The CO32- and HCO3- concentrations being returned to the feed solution can be minimized
355
by acidifying the effluent from the FBCR and stripping the resultant CO2 into a high pH stream,
356
as illustrated in Figure 1. For the data in Figure 4, the pH of the solution entering WAC#3 was
357
12.5 and the carbonate alkalinity was 6.10 meq/L. The effluent from WAC#3 was at a pH value
358
of 5.4 and was fed into the tube side of membrane contactor #2, while a pH=12.2 solution was
359
fed into the lumen side of the contactor. This process reduced the carbonate alkalinity from 6.1
360
to 2.6 meq/L. Carbonate remaining in solution as H2CO3 was stripped out as CO2 gas after
361
entering the well-stirred feed tank with a pH=2. However, in order to prevent any CaCO3
362
precipitation in the base chamber with a feed Ca2+ concentration of 0.025 mM, H2CO3 levels in
363
the feed solution must remain below 0.67 mM.
364
Ion Balance
365
Operation of a closed-loop process using a fixed amount of regenerant solution requires
366
that ions are not lost from the system during the water softening step. Thus, the WAC media
367
must be operated in H+ form, rather than in Na+ form. WAC media in H+ form will only remove
368
temporary (i.e., carbonate) hardness, since HCO3- is necessary to react with the H+ released by
369
the media. In a typical water, the bicarbonate concentration in equivalent units represents from
370
75 to 100% of the total hardness.18 Thus, in most waters there is insufficient bicarbonate for
371
operating the WAC media in H+ form, and the alkalinity of the water will need to be augmented
372
by HCO3-.
ACS Paragon Plus Environment
17
Environmental Science & Technology
Page 18 of 27
373
Figure 5 shows the performance of the softening system where a WBA column containing
374
HCO3- preceded the WAC softening column, as illustrated in Figure S3. Adding alkalinity to the
375
water via the WBA column was able to remove the permanent hardness. For the first 300 empty
376
bed volumes, more than 99.9% of the Mg2+ and more than 98.2% of the Ca2+ were removed.
377
This shows that the WBA regeneration process was able to put sufficient HCO3- on the WBA
378
media, despite the 5 times higher concentration of SO42- (100 mM), as compared to HCO3- (20
379
mM) in the regenerant solution. This result was not expected given that divalent ions are
380
normally preferred over monovalent ions on WBA media.27 The higher than expected uptake of
381
HCO3-can likely be attributed to a loss in ionic selectivity due to the high salt concentration in
382
the regenerant solutions.28 The effluent pH values from the WAC media were almost always
383
within ±1 pH unit of the neutral pH feed solution. Operating the WAC in H+ form with HCO3- in
384
the feed solution resulted in production of H2CO3 and slight acidification of the effluent solution.
385
Variation in the effluent pH values shown in Figure 5 can be attributed to loss of carbonic acid
386
via degassing CO2 from the samples before analysis.
387
Breakthrough experiments were also run without the WBA column preceding the WAC
388
media. These experiments showed immediate breakthrough of Ca2+ and Mg2+, and had effluent
389
pH values from the WAC media ranging from 2.5 to 5.7, as shown in Figure S8 in the
390
Supporting Information. Over the course of 800 empty bed volumes, the total hardness ion
391
removal was equivalent to 87% of the carbonate hardness. Thus, without the WAC loaded with
392
HCO3-, removal of hardness ions was less than the equivalents of HCO3- in the feed stream. This
393
can be attributed to removal of Na+ ions by the media that was equivalent to ~25% of the
394
hardness ions removed. Experiments were also performed with a column of WBA media in the
395
free base form preceding the WAC media. This was not effective, and the WAC media had
ACS Paragon Plus Environment
18
Page 19 of 27
Environmental Science & Technology
396
immediate breakthrough of both Ca2+ and Mg2+, and effluent pH values ranging from 2.4 to 3.6,
397
as shown in Figure S9.
398 399
400 401 402
Figure 5. Effluent hardness ion concentrations and effluent pH values for ion exchange system consisting of WBA media in HCO3-/SO42- form, and WAC media operated in H+ form.
403 404
Removal of Na+ ions (here, a stand-in for all alkali metal ions) during the softening cycle
405
will lead to the accumulation of Na+ ions in the closed-loop regeneration system. Regenerating
406
the WAC using acid with a pH=1 completely removes all Na+ ions and releases them into the
407
regenerant solution. This increase in Na+ concentration will be accompanied by an equivalent
408
loss of H+ ions from the regeneration brine when the media is used again for water softening.
409
In addition to accumulating Na+ ions, SO42- and Cl- ions will also accumulate in the
410
regenerant solution. When the WBA media is regenerated as shown in Figure 1, 11% of the
411
media capacity is occupied by HCO3- and 89% by SO42-. When the WBA media is placed into
412
service, the HCO3- gets replaced by SO42- and Cl- from the feed stream. When the WBA media
413
is regenerated, these SO42- and Cl- ions are added to the regenerant solution. Balancing this
ACS Paragon Plus Environment
19
Environmental Science & Technology
Page 20 of 27
414
increase in SO42- and Cl- concentrations is a loss of HCO3- from the regenerant solution when the
415
media is put back into service. The accumulation of Na+, SO42- and Cl- in the regenerant solution
416
will eventually require dilution of the regenerant solution in order to avoid CaSO4 precipitation
417
in the WAC media during regeneration. In addition, disposal of some of the regenerant solution
418
will be required. The simplest disposal option would be to add it to the softened water. This will
419
not increase the total dissolved solids load of the water as compared to the feed, since the Na+,
420
Cl- and SO42- ions were originally present in the feed water.
421
In addition to accumulating salt, the closed-loop system may also accumulate acid or base.
422
The BMED cell produces identical amounts of acid and base, and thus the performance of the
423
ion exchange media will determine acid or base accumulation in the regenerant solution.
424
Removal of one mole of Ca2+ ionsand precipitating it as CaCO3 (using CO2 gas as the source of
425
carbonate), consumes 2 equivalents of acid for ion exchange regeneration and consumes 2
426
equivalents of base for converting dissolved H2CO3 into CO32-. Similarly, removal one mole of
427
Mg2+ and precipitatitng it as Mg(OH)2, consumes 2 equivalents of acid and 2 equivalents of base.
428
However, to remove one mole of Na+ from the WAC and replace it with H+ consumes one
429
equivalent of acid and zero equivalents of base. Thus, more acid is consumed than base for ion
430
exchange sites occupied by Na+ ions during the softening step. However, for feed water with
431
noncarbonate hardness, base will be lost from the closed-loop system in order to provide
432
alkalinity for hardness removal. The main determining factor whether acid or base accumulates
433
is the difference between the fraction of the total hardness that is noncarbonate hardness, and the
434
fraction of the ion exchange sites on the WAC media that become occupied by Na+ ions during
435
the softening step.
436
equivalents of hardness removed can be expressed as:
For one regeneration cycle, the equivalents of acid accumulated per
ACS Paragon Plus Environment
20
Page 21 of 27
Environmental Science & Technology
437
(6)
438 439
where V is the volume of water softened at hardness ion breakthrough, and the qi are the
440
equivalent concentrations for species i on the WAC media at breakthrough. In instances where
441
there is no noncarbonate hardness, the term:
442
equation (5), and the base accumulation will be equal to
, will be zero in .
443
In many practical circumstances, the accumulation of acid or base will be small. For
444
example, noncarbonate hardness values typically range from 0 to 25% of the total hardness.19
445
The relative loading of Na+ ions to hardness ions on WAC media can be determined from the
446
separation factor (
), defined as:28 [
]
[
]
447
(7)
448
and the aqueous equivalent concentrations of Na+, Ca2+ and Mg2+ ions in the water that is being
449
softened. The
450
recent national survey of major ion concentrations in drinking water reported equivalent
451
concentrations of Na+=1.65 meq/L, K+=0.13 meq/L, Ca2+=1.5 meq/L, and Mg2+=0.74 meq/L.17
452
Using these values, the ratio of alkali metal equivalents to hardness ion equivalents is 0.79. Thus,
453
a typical value for the fraction of the ion exchange media occupied by alkali metal ions can be
454
calculated as:
for the Purolite C104 media used here was determined to be 0.30. A
455
(8)
456
Using a noncarbonate hardness fraction of 0.12, that is in the middle of the typical range, and
457
alkali metal ion removal equal to 24% of the total hardness removal, equation 7 indicates base
458
accumulation in the system equivalent to 12% of the hardness removed. Slight accumulation of
ACS Paragon Plus Environment
21
Environmental Science & Technology
Page 22 of 27
459
base may be beneficial, since excess base could be added to the softened water that was acidified
460
by the softening process. Alternatively, if acid accumulates and is added back into the softened
461
water, degassing of the water may be desirable to raise the pH.
462
Small amounts of water will also be lost from the system due to water splitting inside the
463
bipolar membrane. For water with 5 meq/L of hardness ions, ~5 meq of acid and base will be
464
needed per liter of water treated. In this case, producing acid and base via the splitting of water
465
represents a fractional water loss of 9.0 x10-5.
466
Energy Requirements
467
The practicality of the closed-loop regeneration process will depend on the energy required
468
for electrochemically producing the acid and base streams.
469
Information shows the required voltage per unit cell ( ) as a function of current density for
470
operating the BMED stack using 100 mM Na2SO4 as the feed solution. When the cell is
471
operated at a current density of 35 mA/cm2, the current utilization ( ) is the same for both acid
472
and base production, and is 75%. Thus, the energy required for producing 1 mole of acid or 1
473
mole of base can be calculated from the ratio of the applied power (
474
rate of acid or base (
Figure S10 in the Supporting
) to the molar production
), as given by:
475
(9)
476
where I is the applied current, n is the number of unit cells in the BMED stack, and F is
477
Faraday’s constant. Since they are produced simultaneously, equation 8 ascribes half the energy
478
for acid production and half for base production. For operating the cell at a current density of 35
479
mA/cm2, the applied voltage per unit cell is 4 V, and the energy required per mole of acid or base
480
is 0.071 kWh. Assuming an electrical energy cost of $0.07/kWh29, the cost for 1 mole of acid
ACS Paragon Plus Environment
22
Page 23 of 27
Environmental Science & Technology
481
plus 1 mole of base is $0.010. This is more than 15 times lower than the total cost of $0.155 for
482
purchasing acid and base from a local supplier in 180 lb containers (Hill Brothers Chemical Co.,
483
Tucson), where the cost per mole of 35% HCl is $0.069 and 99% NaOH is $0.086. In addition
484
to the energy cost to operate the cell, energy will be required for pumping the solutions through
485
the cell. Past experience shows that the energy required for this is similar to the energy required
486
to operate the BMED stack.5 Thus, even when these costs are included, the energy costs for
487
producing the acids and bases are approximately an order of magnitude smaller than those for
488
purchasing acids and bases.
489
Scalability
490
The membrane area needed per volume of water softened can be estimated from data in this
491
study. The stoichiometric amount of acid and base required for treating 1000 m3/d of water with
492
5 meq/L of hardness is 5000 eq/d for removing hardness minerals from the WAC. In addition,
493
the WAC will remove alkali metal ions equal to ~25% of the hardness ions removed. Thus, the
494
amount of acid and base required will be ~6250 eq/d. A BMED cell with 1 m2 of membrane area
495
operating at 35 mA/cm2 with
496
m2 of BMED membrane area is required to produce 6250 eq of acid and base per day. This can
497
be accommodated in one stack with 107 unit cells with membranes that are 50 cm by 50 cm in
498
dimension. This is within the range of commercial stacks that may have up to 300 unit cells.5
= 0.75 produces 235 eq of acid and base per day. Therefore, 26.7
499
Acid and base wastage in the system will increase the required membrane area over the
500
stoichiometric amount. In order to operate the system as a closed loop, acid is required to reduce
501
the pH of the solutions exiting the FBCR. If the FBCR is operated at a pH of 11, and the
502
concentration of the carbonate species are each 1 mM, 14 meq/L of acid is required to remove
503
CO32- and HCO3- (as CO2), and to acidify the solution to a pH value of 2. For a system operating
ACS Paragon Plus Environment
23
Environmental Science & Technology
Page 24 of 27
504
at 35 mA/cm2, the acid generation rate is 225 meq/L when operated at the flow rates used here
505
(Figure 3). Thus, continuous acid and base consumption of 14 meq/L associated with removing
506
carbonate and acidifying the FBCR effluent would only increase the required acid and
507
production by 6.2% over the stoichiometric amount needed for ion exchange regeneration.
508 509
Acknowledgements
510
The National Science Foundation (CBET-1235596) provided funding for this work
511 512
Conflict of Interest Disclosure
513
The authors declare no competing financial interest.
514 515
Supporting Information
516
Figures illustrating: the experimental apparatus, the configuration of the water softening system,
517
a bipolar membrane unit cell, the voltage drop per unit cell, sulfate concentrations in acid stream
518
as a function of current density, hardness ion concentrations in WAC effluent and in FBCR
519
versus elapsed regeneration time, effluent hardness ion concentrations and pH for WAC media
520
operated in H+ form, effluent hardness ion concentrations and pH for WAC media operated in H+
521
form with preceding WBA media operated in free base form, voltage drop per unit cell versus
522
current density, and Tables illustrating membrane contactor performance and levels of hardness
523
ion removal and hardness ion concentrations in the FBCR are provided in the Supporting
524
Information. This material is available free of charge via the Internet at http://pubs.acs.org.
525
ACS Paragon Plus Environment
24
Page 25 of 27
TOC Art
X-
-
OH
M+
Acid + + + + + + + + + + + + + + + + +
-
+
H
DI + + + + + + + + + + + + + + + + +
+
M
X-
Base -
-
OH
Acid + + + + + + + + + + + + + + + + +
-
+
H
X-
+ + + + + + + + + + + + + + + + +
M+
Cathode
Anode
M
-
Water Splitting Catalyst Layer
Base +
Water Splitting Catalyst Layer
526
Environmental Science & Technology
X-
Salt Solution
527 528
ACS Paragon Plus Environment
25
Environmental Science & Technology
529
Page 26 of 27
References
(1) Water Quality and Treatment: a Handbook of Community Water supplies, 5th ed.; McGraw Hill: New York, 1999. (2) Management of water treatment plant residuals; American Water Works Association: Denver, CO, 1996. (3) Central Arizona Salinity Study, Phase II, Final Report; U.S. Bureau of Reclamation, 2006. (4) Santa Clara River Chloride Reduction Ordinance of 2008; Santa Clarita Valley Sanitation District of Los Angeles County, 2008. (5) Strathmann, H. Ion-Exchange Membrane Separation Processes; Elsevier: Amsterdam, 2004. (6) Badruzzaman, M.; Oppenheimer, J.; Adham, S.; Kumar, M. Innovative beneficial reuse of reverse osmosis concentrate using bipolar membrane electrodialysis and electrochlorination processes. J. Memb. Sci. 2009, 326, 392–399. (7) Chiao, Y. C.; Chlanda, F. P.; Mani, K. N. Bipolar membranes for purification of acids and bases. J. Memb. Sci. 1991, 61, 239–252. (8) Mani, K. N.; Chlanda, F. P.; Byszewski, C. H. Aquatech membrane technology for recovery of acid/base values for salt streams. Desalination 1988, 68, 149–166. (9) Onsager, L. Deviations from Ohm’s law in weak electrolytes. J. Chem. Phys. 1934, 2, 599615. (10) Graveland, A.; van Dijk, J. C.; de Moel, P. J.; Oomen, J. H. C. M. Developments in water softening by means of pellet reactors. J. Am. Water Works Assoc. 1983, 75 (12), 619-625. (11) Harms, W. D.; Robinson, R. B. Softening by fluidized bed crystallizers. J. Env. Eng. 1992, 118, 513–529. (12) Van der Veen, C.; Graveland, A. Central softening by crystallization in a fluidized bed process. J. Am. Water Works Assoc. 1988, 80 (6), 51-58. (13) Stanford, B.D.; Leising, J.F.; Bond, R.G.; Snyder, S.A. Inland desalination: Current practices, environmental implications, and case studies in Las Vegas, NV. Sustainability Sci. Eng. 2010, 2, 327-350. (14) Mahvi, A. H.; Shafiee, F.; Naddafi, K. Feasibility study of crystallization process for water softening in a pellet reactor. Int. J. Environ. Sci. Technol. 2005, 1 (4), 301-304. (15) van Schagen, K.M.; Rietveld, L.C.; Babuska, R.; Kramer, O.J. Model-based operational constraints for fluidised bed crystallisation. Water Res. 2008, 42, 327–337. (16) Giesen, A.; Erwee, H.; Wilson, R.; Botha, M.; Fourie, S. Experience with crystallization as sustainable, zero-waste technology for treatment of wastewater. In Proceedings of the International Mine Water Conference; Pretoria, S Africa, Oct 19-23, 2009; ISBN 978-009802623-5-3.
ACS Paragon Plus Environment
26
Page 27 of 27
Environmental Science & Technology
(17) Patterson, K.Y.; Pehrsson, P.R.; Perry, C.R. The mineral content of tap water in United States Households. J. Food Compost. Anal. 2013, 31 (1), 46-50. (18) Davis, M. Water and Wastewater Engineering; McGraw-Hill: New York, 2010. (19) Mechenich, C.; Andrews, E. Home Water Safety: Interpreting Drinking Water Test Results; University of Wisconsin Cooperative Extension Publication G3558-4, 2004 (20) Methods for the Chemical Analysis of Water and Wastes (MCAWW) (EPA/600/4-79/020) (21) Parkhurst, D.L.; Appelo, C.A.J. Description of input and examples for PHREEQC version 3: a computer program for speciation, batch-reaction, one-dimensional transport, and inverse geochemical calculations. U.S. Geol. Surv. 2013, No. 6-A43. (22) Parkhurst, D.L.; Appelo. C.A.J. User's guide to PHREEQC (Version 2): A computer program for speciation, batch-reaction, one-dimensional transport, and inverse geochemical calculations. U.S. Geol. Surv. 1999. (23) Davis, J.R.; Chen, Y.; Baygents, J.C.; Farrell, J. Production of acids and bases for ion exchange regeneration from dilute salt solutions using bipolar membrane electrodialysis. ACS Sustainable Chem. Eng. 2015, 3 (9), 2337-2342. (24) Bornak, W. Ion Exchange Deionization for Industrial Users; Tall Oaks Publishing: Littleton, CO, 2003. (25) Tai, C.Y.; Chien, W.C.; Chen, C.Y. Crystal growth kinetics of calcite in a dense fluidizedbed crystallizer. A.I.Ch.E.J. 1999, 45, 1605–1614. (26) van Schagen, K.M.; Rietveld, L.C.; Babuska, R.; Kramer, O.J. Model-based operational constraints for fluidised bed crystallisation. Water Res. 2008, 42, 327–337. (27) Clifford, D.; Weber, W. J. The determinants of divalent/monovalent selectivity in anion exchangers. React. Polym. 1983, 1, 77-89. (28) Clifford, D. Ion Exchange and Inorganic Adsorption in Water Quality and Treatment, 5th ed.; R. D. Letterman ed.; American Water Works Association, McGraw-Hill: New York, 1999; pp 9.1-9.91. (29) Eia. gov., Electricity Data Browser; http://www.eia.gov/electricity/data/browser/#/topic/7?agg=2,0,1&geo=g&freq=M (accessed Dec. 5, 2014).
ACS Paragon Plus Environment
27