Evaluating a tap water contamination incident attributed to oil contamination by non-targeted screening strategies Beili Wang, Yi Wan, Guomao Zheng, and Jianying Hu Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.5b05755 • Publication Date (Web): 10 Feb 2016 Downloaded from http://pubs.acs.org on February 13, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 29
Environmental Science & Technology
1
Evaluating a tap water contamination incident attributed to oil contamination by
2
non-targeted screening strategies
3
Beili Wang, Yi Wan*, Guomao Zheng, Jianying Hu
4 5 6 7
1
Laboratory for Earth Surface Processes, College of Urban and Environmental Sciences,
Peking University, Beijing 100871, China (Received
)
*Address for Correspondence:
8 9 10 11 12 13 14 15
Address for Correspondence
16
Dr. Yi WAN
17
College of Urban and Environmental Sciences
18
Peking University
19
Beijing 100871, China
20
TEL & FAX: 86-10-62759126
21
Email:
[email protected] 22
1
ACS Paragon Plus Environment
Environmental Science & Technology
23
ABSTRACT
24
The present study applied non-targeted screening techniques as a novel approach to
25
evaluate the tap water samples collected during the “4.11” tap water pollution incident
26
occurred on April 11, 2014 in Lanzhou in west China. Multivariate analysis (PCA and
27
OPLS-DA) of about 3000 chemical features obtained in extracts of tap water samples by
28
ultrahigh-pressure liquid chromatography quadrupole time-of-flight mass spectrometry
29
(UPLC-QTOF-MS) analysis showed significantly different chemical profiles in tap water
30
from pollution regions versus reference regions during the event. These different chemical
31
profiles in samples from different regions were not observed in samples collected during the
32
non-pollution period. The compounds responsible for the differences in profiles between
33
regions were identified as naphthenic acids (NAs) and oxidized NAs (oxy-NAs) after the
34
sample extracts underwent bromination to explore saturations, dansylation to identify
35
hydroxylations and corresponding MS/MS mode analysis. A consistent finding was further
36
observed in the targeted analysis of NA mixtures, demonstrating that the Lanzhou “4.11” tap
37
water pollution incident could be attributed to oil spill pollution, and NA mixtures would be a
38
marker for oil contamination. Such evaluations can help to rapidly discriminate pollution
39
sources in accidental pollution events and contribute to regular water monitoring management
40
of water safety issues.
41
Keywords: Water safety, tap water, accidental pollution events, metabolomics, naphthenic
42
acids
2
ACS Paragon Plus Environment
Page 2 of 29
Page 3 of 29
43
Environmental Science & Technology
Introduction
44
Recent decades have witnessed a rise in the environmental awareness of water safety,
45
which is one of the national issues holding the greatest socio-economic threats to national
46
security.1-3 The accidental release of pollutants into the environment can result in the loss of
47
life and property and severely affect the safety of water, especially in countries undergoing
48
rapid industrial and urban development.1, 4, 5 The number of water pollution accidents was
49
reported to be 6677 from 2000 to 2008 in China according to the Ministry of Environmental
50
Protection (MEP), and many of these events have threatened the public health of local
51
communities.6-7 It is therefore urgent to strengthen the capabilities to monitor and properly
52
judge events of accidental pollution.
53
Target screening is currently the main strategy to identify and quantify pollutants for
54
which standards are available.8-10 To provide maximum selectivity and sensitivity, only
55
characteristic ions or ion transitions of targeted analytes are monitored in target ion
56
monitoring.3, 11-13 However, no preliminary information concerning responsible pollutants was
57
known when the accidents occurred in most pollution events.6-7 The target screening methods
58
were specifically developed for a certain group of substances, and would miss the compounds
59
that are not selected at the start of the analyses. For example, unusual odors were reported in
60
river water and tap water on May 10, 2014 in Jingjiang city, China, and the city had to stop
61
the supply of tap water for seven hours, but the causes of the accident were still not clear even
62
the Chinese MEP continuously monitored the water samples in 62 locations along the river
63
for 32 hours. In contrast, the tentative non-targeted techniques are superior for screening of
64
unknown compounds.14-16 The non-targeted screening is substantially harmonized by 3
ACS Paragon Plus Environment
Environmental Science & Technology
65
researchers from 18 institutes from 12 European countries recently due to its ability for
66
identification of a wider range of compounds in water samples.17 However, identifying the
67
major functional groups of unknown compounds based on the high resolution data combined
68
with limit fragmentations is a major challenge for clarifying the structures of the non-targeted
69
mass.15,
70
derivatization regents would specifically react with different functional groups, for example,
71
dansyl chloride could selectively react with hydroxyl groups and generate a collisional
72
fragmentation of dansyl moiety.18-20 Thus derivatizations combined with MS/MS analysis
73
could help identify the structure of responsible pollutants in the sample extracts.
17
More suitable for this purpose is chemical derivatizations, since some
74
To test the hypothesis about the advantage of non-targeted screening in water analysis,
75
the proposed non-targeted techniques were applied to evaluate a tap water contamination
76
incident. On April 11, 2014, the so-called “4.11” tap water pollution incident occurred in
77
Lanzhou, Gansu province, China, during which the concentrations of benzene (up to 200 µg/L)
78
in the city’s tap water rose to 20 times above the national limit according to the city’s
79
environmental protection office. More than 800 metric tons of polluted water were supplied
80
before the source was found. We screened all the non-targeted mass in tap water samples
81
collected during the events and a non-pollution period. The chemical profiles were obtained
82
from sufficiently accurate mass measurements, and thousands of resulting chemical formulae
83
underwent multivariate analysis to identify the responsible pollutants. Chemical
84
derivatizations including bromination and dansylation were applied to identify the saturation
85
or hydroxylation of the responsible pollutants. The structures of the identified pollutants were
86
finally clarified together with a targeted analysis to reveal the pollution sources in the event. 4
ACS Paragon Plus Environment
Page 4 of 29
Page 5 of 29
Environmental Science & Technology
87
Materials and methods
88
Sample collection
89
On April 11, 2014, concentrations of benzene were reported to be more than 20 times
90
above the national limits after comprehensive target screening of the water samples following
91
the national guidelines for drinking water quality by the local environmental protection office.
92
During the “4.11” tap water pollution incident, Xigu (XG) and Anning (AN) districts were
93
reported to the worst-hit areas according to the city’s environmental protection office, and
94
Honggu (HG), Qilihe (QLH) and Chengguan (CG) districts were the less affected area
95
possibly due to different distances to the location of the pollution sources. On the same day of
96
the accident, 14 tap water samples were collected from the heavily contaminated XG and AN
97
districts, respectively, and 15 tap water samples were taken from three other districts of
98
Lanzhou city including HG, QLH and CG districts (Figure 1). Six months after the accident
99
(October 10, 2014), tap water samples were collected again from the same locations to allow
100
comparisons of the pollutants in the water samples collected at the time of the accident with
101
those in the non-pollution period. Water samples were collected from the kitchen tap and
102
allowed to flow from the tap without an aerator for about 3 min prior to completely filling the
103
sample bottle with no headspace. All water samples were collected in 500 mL amber glass
104
bottles, which were washed by methanol and pure water before use.
105
Sample preparation
106
Water samples were stored with ice during transportation and extracted within 6 h in the
107
local laboratory after being filtered by a glass microfiber filter GF/C 1.2 µm (Whatman,
108
Maidstone, UK). The details of chemicals and reagents are provided in the Supplementary 5
ACS Paragon Plus Environment
Environmental Science & Technology
109
Data. 500 mL of water spiked with 0.1 µg of surrogate standards (12-oxochenodeoxycholic
110
acid and 1-pyrenebutyric acid) was extracted on a SPE MAX cartridge (Oasis MAX, 6 mL,
111
150 mg, Waters, USA), of which the sorbent is synthesized from the reversed-phase Oasis
112
HLB copolymer and features two retention mechanisms: anion exchange and reversed phase.
113
This makes the cartridge suitable for extractions of both neutral and charged compounds in
114
water samples. The cartridges were preconditioned by 6 mL of methanol and 6 mL of pure
115
water, and then rinsed with 6 mL of 5% ammonia. After dried under a flow of nitrogen, the
116
MAX cartridge was eluted with 12 mL ethyl acetate saturated with hydrochloric acid (2M
117
HCl:ethyl acetate =1:10, v/v). The elute was washed with pure water for three times and
118
reconstituted with 100 µL of methanol for analysis by an ultrahigh-pressure liquid
119
chromatography (UPLC) coupled to a quadrupole time-of-flight mass spectrometer
120
(QTOF-MS) with electrospray ionization in negative ionization mode (ESI-).
121
Non-targeted UPLC-QTOF-MS analysis
122
Non-targeted chemical profiling LC-MS analysis was carried out on a Waters ACQUITY
123
UPLC coupled to a Xevo QTOF-MS (G2, Waters). An ACQUITY UPLC BEH C18 column
124
(2.1×100 mm, 1.7 µm particle size) and a mobile phase consisting of (A) ultrapure water
125
containing 10 mM ammonium acetate and (B) methanol were used for chromatographic
126
separation, with a flow rate of 0.2 mL min-1, to obtain the abundant responses of all the
127
potential chemicals in water samples. The column was maintained at 40°C, and the injection
128
volume was 3 µL. Mass spectra were collected in full-scan from m/z 80 to 1000. Spectral
129
peaks were deconvoluted and aligned using Waters MarkerLynx (version 4., Waters
130
Corporation, Milford, MA) with the following parameters: data collection parameters were set 6
ACS Paragon Plus Environment
Page 6 of 29
Page 7 of 29
Environmental Science & Technology
131
as intensity threshold 500 counts, mass window level at 50-1000 Da, retention time window
132
of 16 min, and noise elimination level at 6.00. The data sets (spectral peak areas of compound
133
divided by sum area of two surrogate standards’ spectral peak) were normalized to total
134
spectral area for each sample, and exported to SIMCA-P+ (ver. 13.0; Umetrics) for
135
multivariate statistical analysis.
136
Markers identification (non-targeted analysis)
137
The identities of discriminatory chemicals were determined by their accurate mass
138
composition and from fragmentation data, which were obtained from collision-induced
139
dissociation (CID) using QTOF-MS/MS analysis with electrospray ionization in negative
140
ionization mode (ESI-). MS/MS mode was applied to acquire fragmentation data by manually
141
setting the m/z values of precursor ions, which are used to derive the structural information
142
about these molecules in combination of precursor m/z and retention time. To eliminate
143
compounds with carbon-carbon double bonds, the residues were redissolved in 2 mL of CCl4
144
and reacted with 8 mL of 1% (v/v) bromine in CCl4.21-22 Excess bromine was removed by
145
reacting with 100 µL of 2-pentene, and redissolved in 100 µL of acetonitrile after drying by a
146
gentle nitrogen. The extracts were further derivatized with dansyl chloride (DNS) to identify
147
the chemical nature of alcohol group according to the procedure reported previously (2013).23
148
Briefly, the extract were added with 0.2 mL pyridine and a mixture (0.2 mL) of 30 mg/mL
149
DNS and 30 mg/mL catalyst (4-dimethylamiopryidine) dissolved in DCM. The mixture was
150
shaken with a vortex device for 1 min and incubated at 65°C for 60 min. The residuals were
151
blown to dryness and then dissolved with 0.1 mL of acetonitrile for UPLC-QTOF-MS/MS
152
analysis. UPLC-QTOF-MS/MS analysis was used to characterize the fragmentation pattern of 7
ACS Paragon Plus Environment
Environmental Science & Technology
153
each maker feature of interest (as determined by univariate and multivariate techniques)
154
according to the fragmentation ions reported in our previous study.23-24 MS/MS was carried
155
out on the Waters QTOF system described above with a 10 - 30V collision energy ramp and a
156
50 - 1000 Da mass range.
157
Targeted analysis
158
To identify and quantify the groups of identified markers, water samples were measured
159
using the same LC-MS method with that in non-targeted analysis. To correct for variation
160
between batches in the targeted analysis, quality assurance and quality control (QA/QC) was
161
applied to each chemical concentration value. Briefly, all equipment were rinsed with acetone
162
and hexane to avoid sample contamination. A procedural blank was incorporated in the
163
analytical procedures for every batch of 10 samples, and the total amount of NAs and
164
oxy-NAs in field blank samples were less than 3.5±0.4 µg. The efficiencies of the sample
165
preparation procedure was assessed by analyzing water samples collected from each district
166
spiked with standard solutions of model NAs and oxy-NAs, of which the detail information
167
was provided in SI Table S1. The absolute recoveries of model NA and oxy-NA compounds
168
were 90±25%, 92±19%, 82±18%, 88±24% and 99±29% in spiked water samples collected
169
from XG, CG, QLH, AN and HG, respectively (n=15), of which the recoveries (82-99%)
170
were in the acceptable range for semi-quantifications of NA mixtures and the relatively high
171
deviations were possible due to the poor quantification of TOFMS. Surrogate standards
172
(1-pyrenebutyric acid and 12-oxochenodeoxycholic acid) were spiked to samples prior to
173
extraction to compensate for the loss of target compounds during the extraction process and
174
correct the variation of instrument response and matrix effect. The efficiencies of the sample 8
ACS Paragon Plus Environment
Page 8 of 29
Page 9 of 29
Environmental Science & Technology
175
preparation procedure were assessed by analyzing water samples collected from each district
176
spiked with surrogate standard solutions. Recoveries of 1-pyrenebutyric acid and
177
12-oxochenodeoxycholic acid were 70±25% and 75±29% (n=29) in all analyzed water
178
samples, respectively. The MDLs were 1.2-27 ng/L and 0.05-0.35 ng/L for NAs and oxy-NAs
179
in water samples, respectively. The detail analytical information about targeted analysis of
180
PAHs and alkyl-PAHs were provided in Supporting Information (SI).
181
Statistical analysis
182
Normalized peak area matrices were exported to SIMCA-P 13.0 (Umetrics, Umea,
183
Sweden) for multivariate statistical analysis. Spectral regions containing blank water and
184
methanol signals were excluded from the analysis. Clustering of the samples was assessed
185
using principal component analysis (PCA) to reveal the differences among sampling districts.
186
Orthogonal partial least-squares-discriminant analysis (OPLS-DA) was carried out to generate
187
the maximum separation between the classes of reference regions versus pollution regions.
188
Each OPLS-DA model was evaluated by both the internal permutation test and external
189
validation test. Unpaired Student's t-tests were employed to ensure that the polluted markers
190
extracted with holistic OPLS-DA analysis were significantly differentially expressed between
191
the polluted and control groups. P value threshold of 0.05 was used to define the significance.
192 193
Results and discussion
194
Changes in chemical profiles of the tap water
195
The evolution of HRMS coupled with ultrahigh-pressure liquid chromatography (UPLC)
196
with superior sensitivity and selectivity has opened up new windows of opportunity for 9
ACS Paragon Plus Environment
Environmental Science & Technology
and
identifying
the
compounds.25-29
unknown
Page 10 of 29
197
profiling
Using
the
non-targeted
198
UPLC-QTOF-MS method, 3391 chemical features were extracted for each water sample.
199
PCA score plots were used to determine whether the chemical profile in the water samples
200
from each district were sufficiently unique to distinguish the different polluted regions. As
201
shown in Figure 2a, clear separations were observed between the districts of XG and AN and
202
those of HG, CG and QLH. This is consistent with the report by the city’s environmental
203
protection office that XG and AN districts were the most polluted areas in the “4.11”
204
incident.30 In comparison, the PCA score plots illustrated no significant differences among the
205
five districts for the water samples collected during the non-pollution period (Figure 2b),
206
suggesting that the chemical profiles of the tap water of the five districts in Lanzhou were
207
generally similar. The results demonstrated that the unknown pollution sources caused
208
significantly different chemical profiles in the tap water from XG and AN districts compared
209
with the other districts during this event, and the profile would provide important information
210
for clarifying the potential pollution sources.
211
Non-targeted analysis of PCA of the five districts showed significant differences
212
between the XG and AN districts and the QLH, CG and HG districts during the pollution
213
period. Therefore, we considered XG and AN as the pollution region and QLH, CG and HG
214
districts as the reference region. To investigate the key pollutants in tap water from the
215
polluted region, the variances of chemical profiles between the pollution region and reference
216
region were examined by supervised multivariate OPLS-DA. The OPLS-DA scatter plots
217
showed obvious clustering of tap water samples from the two regions during the event (R2
218
(cum) = 0.993, Q2 (cum) = 0.943, Figure 2c), whereas the OPLS-DA model for samples 10
ACS Paragon Plus Environment
Page 11 of 29
Environmental Science & Technology
219
collected in the non-polluted period showed poor predictive ability (R2 (cum) = 0.789, Q2
220
(cum) = -0.327, Figure 2d). This is consistent with the PCA results that samples from the
221
pollution and reference regions can only be separated during the “4.11” tap water pollution
222
incident. The quality of the OPLS-DA model was further evaluated by a permutation test
223
(with 100 iterations) performed in the corresponding PLS-DA model. The Q2 and R2 values in
224
the permutation test for the modeling of samples collected during the event were higher than
225
the original points, and the regression of the Q2 points intersected the vertical axis below zero
226
(SI Figure S1), strongly indicating that the OPLS-DA model was statistically valid. However,
227
the permutation test for the modeling of samples collected during the non-pollution period
228
showed that the OPLS-DA model was not valid (SI Figure S1), which is consistent with the
229
poor predictive ability of the model. To select statistically significant chemicals related to the
230
differences between regions during the event, an S-plot was constructed on the basis of the
231
validated OPLS-DA model (SI Figure S2). Variables that are at the edges of the sigmoidal
232
curve can be considered as suitable targets for investigation as markers of exposure, and about
233
78 peaks responsible for the separation were considered as potential markers for clarifying the
234
pollution sources of the accident.
235
The non-targeted screening via high resolution MS has gained increasing importance for
236
monitoring unknown organic trace substances in water resources.31 Generally, significantly
237
different chemical profiles were observed among different types of water such as drinking
238
water, ground water, wastewater etc.15, 31 In the present study, distinct chemical profiles were
239
firstly observed in tap water samples from different regions in the water pollution incident,
240
and the difference disappeared during the non-pollution period. In most pollution events, no 11
ACS Paragon Plus Environment
Environmental Science & Technology
241
preliminary information concerning responsible pollutants was known when the accidents
242
occurred. The traditional target analytical methods were specifically developed for a certain
243
group of substances, and would miss the compounds that are not selected at the start of the
244
analyses. In comparison, the non-targeted screening technique could screen all possible
245
chemicals in the sample extracts and identify the responsible pollutants based on comparisons
246
between polluted and reference samples. For examples, a suite of polar petroleum makers
247
were identified for indicating the oil spill source based on the PCA analysis of elemental
248
composition data in oils of fuel tanks and environmental field samples.32 In the present study,
249
the non-targeted screening strategies is based on the assumption that no preliminary
250
information concerning the pollution sources was known, and the method provided a new
251
comprehensive monitoring approach of organic trace substances for source clarifications
252
and/or early warning in accidental pollution events.
253
Identification of potential markers
254
The identification of the responsible pollutants for the regional differences is a great
255
challenge due to the lack of comprehensive spectral libraries for soft ionization techniques in
256
contrast with the standards or public databases of metabolites such as Metlin, HMDB, and
257
KEGG.15, 17 The structures of the non-targeted mass could not be confirmed only based on the
258
high resolution data combined with results of compound database queries (e.g., ChemSpider),
259
and identifying the major functional groups of unknown compounds is even more difficult. In
260
the present study, potential markers were identified mainly through MS fragmentations and
261
chemical derivatization of the compounds. The molecular formula of the compounds can be
262
roughly determined by the accurate molecular weight by HRMS and MS/MS spectra, and 12
ACS Paragon Plus Environment
Page 12 of 29
Page 13 of 29
Environmental Science & Technology
263
chemical derivatizations including bromination and dansylation were applied to explore the
264
saturation or hydroxylation of the pollutants.
265
The 78 ions of interest were firstly lessened to about 52 ions by Student’s t-test and then
266
identified from their accurate mass composition and elemental composition. Many structures
267
were present in electrospray ionization (ESI) as the [M−H]- ion, and a number of the ions
268
were found to be compounds with the molecular formula of CnH2n+ZOx (e.g. C16H32O2,
269
C18H36O2, C12H24O2, C18H34O2, C13H20O4 C15H22O4, C14H20O5 and C15H22O5), of which the
270
intensities in samples from the pollution region were, on average, 29-fold higher than those in
271
samples from the reference region in the event. Bromination was first conducted to eliminate
272
compounds with carbon-carbon double bonds, and the variations of peak intensities of the
273
CnH2n+ZOx ions between non-brominated and brominated samples ranged from -5.2% to 1.8%,
274
suggesting that these compounds contained cyclic structures. The brominated extracts were
275
further characterized in the QTOF-MS/MS analysis to investigate their ESI mass spectral
276
fragmentation pathways. As shown in Figure 3 and Table 1, molecular ions ([M−H]−) and
277
[M−H−H2O]− were observed for C16H32O2, C18H36O2, C12H24O2 and C18H34O2, suggesting that
278
these compounds were saturated acids or ring-containing acids (naphthenic acids (NAs)). Two
279
more fragment ions of [M−H−CO2]− and [M−H−H2O−CO2]− were found for the ions of the
280
C13H20O4, C15H22O4, C14H20O5 and C15H22O5 species (Figure 3 and Table 1). As shown in SI
281
Figure S4, neutral loss of CO2 and H2O moieties were the characteristic mass fragmentations
282
for mono-oxidized acids (12-oxochenodeoxycholic acid and 12-hydroxystearic acid), and four
283
diagnostic fragments were generated by the loss of more H2O or both CO2 and H2O moieties
284
for 12-oxochenodeoxycholic acid. Thus, neutral losses of the CO2 and H2O moieties were the 13
ACS Paragon Plus Environment
Environmental Science & Technology
285
characteristic mass fragmentations for oxidized NAs (oxy-NAs), which is similar to the
286
fragmentation ions of commercial NAs by ESI--MS/MS analysis reported previously.24, 33-36
287
The loss of H2O, CO2 and H2CO3 moieties in CnH2n+ZO4 and CnH2n+ZO5 indicated that these
288
compounds were hydroxylated NAs or ketonic NAs, not compounds with ester or di-acid
289
groups. Moreover, the retention times of C13H20O4, C15H22O4, C14H20O5 and C15H22O5 were
290
earlier than those of the non-oxidized acids (Table 1), which is consistent with the elution
291
sequence of the oxidized acid and non-oxidized acids reported previously.23-24 The above
292
results indicated that these ions were possibly NAs and/or oxy-NAs, both soluble components
293
of petroleum.
294
To further identify the chemical nature of the oxy-NAs (hydroxyl or ketone) in the
295
extracts, a derivatization method with DNS was applied. DNS is only reactive with hydroxyl
296
groups in optimized derivatization conditions, and derivatized compounds were analyzed in
297
positive ion mode, which excluded the interferences of acids in the sample extracts. As shown
298
in SI Figure S5, ionization and fragmentation of the dansyl derivatives of hydroxylated NA
299
standards resulted in protonated molecular ions [M+H]+ and produced product ions at m/z
300
252.0694 and m/z 171.1048. The ion m/z 252.0694 is the protonated molecular ion of DNS,
301
and the ion m/z 171.1048 originates from a cleavage of a C-S bond in the dansyl portion of
302
the molecule (SI Figure S5). Figure 3 and Table 1 show the MS/MS fragment ions of dansyl
303
derivatives from the corresponding oxy-NAs in the extracts of tap water from the pollution
304
region in the event. The major dansyl derivative parent and product ions, not observed before
305
derivatization, were similar to the fragmentation pattern of hydroxylated NA standards. While
306
the reference standards were not commercially available for these identified compounds, the 14
ACS Paragon Plus Environment
Page 14 of 29
Page 15 of 29
Environmental Science & Technology
307
fragmentation patterns of the compounds were same with those of standards of model
308
oxy-NAs before or after the derivatization. The results demonstrated that the C13H20O4,
309
C15H22O4, C14H20O5 and C15H22O5 detected in the sample extracts were mainly composed of
310
hydroxylated NAs. This study suggests that saturated fatty acids, NAs and hydroxylated NAs
311
would be the key pollutants for regional discrimination in the event.
312
Targeted analysis of naphthenic acids
313
NA mixtures are a group of chemicals with formula of CnH2n+ZOx (x=3, 4, 5), where “n”
314
is the carbon number and “Z” refers to the cylinder number. “Z” is zero or a negative, even
315
integer that specifies the hydrogen deficiency resulting from ring formation.37-39 NA mixtures
316
are the primary toxic components in oil sands process-affected waters produced at the oil
317
sands extraction plants in northeastern Alberta, Canada.40 Previous studies have shown that
318
NA mixtures are potential indicators for oil contamination in the aquatic environment because
319
that they are polar and soluble components of petroleum and persist in the environment.41 The
320
detection of NA mixtures in the polluted tap water is consistent with the suspected cause of
321
the event, i.e., that an oil pipeline near the water plant leaked, which led to the concentration
322
of benzene exceeding the standard. The concentrations of the NA mixtures were generally
323
semi-quantified based on integration of the hump peak of the NA congeners assuming that the
324
responses for individual NA isomers in the hump peaks were similar because the separation
325
method and standards for all of the individual NAs were not available.42-45 The peak intensity
326
of the NAs and oxy-NAs could not be automatically integrated by MakerLynx due to the
327
characteristic “humps” of the NA mixtures. Therefore, about 150 NA congeners were
15
ACS Paragon Plus Environment
Environmental Science & Technology
328
manually integrated and semi-quantified with the method reported previously for further
329
multivariate statistical analysis.23
330
A consistent finding was observed in the non-targeted and targeted analysis. In the
331
OPLS-DA score plots, tap water samples collected from the pollution region during the event
332
could be clearly separated from those collected from the reference regions (R2 (cum) = 0.89,
333
Q2 (cum) = 0.508), but no obvious separation was observed for samples collected during the
334
non-pollution period (R2 (cum) = 0.584, Q2 (cum) = 0.0871) (SI Figure S6). The permutation
335
test also showed that only the OPLS-DA model for samples collected during the event was
336
statistically valid (SI Figure S7). These results demonstrated that the NA mixture profile from
337
the UPLC-QTOF-MS analysis consistently produced clearly defined groupings and a highly
338
valid model in OPLS-DA analysis for tap water samples collected during the event. Figure 4
339
shows the boxplots of the concentrations of detected NAs and oxy-NAs in tap water samples
340
from the pollution and reference regions during the event. Concentrations of CnH2n+ZOx with
341
Z values of -8 to 0 and x of 2 to 5 in water samples from the pollution region were statistically
342
significantly higher than those in samples from the reference region. Especially for ions of
343
267.2324 and 281.2481 (one ring) and 219.139, 401.342, 171.1021 and 183.1021 (four rings
344
and one hydroxyl), concentrations were below detection limits in samples from the reference
345
regions but relatively high in samples from the pollution region (Figure 4). The results
346
together with the non-targeted OPLS-DA analysis confirmed that the “4.11” tap water
347
pollution incident in Lanzhou could be attributed to oil spill pollution. A previous study also
348
screened elemental compositions of thousands features by high resolution FT-ICR MS in two
349
tanks of heavy fuel oils and field oil from a rocky shoreline along San Francisco Bay 16
ACS Paragon Plus Environment
Page 16 of 29
Page 17 of 29
Environmental Science & Technology
350
following the M/V Cosco Busan oil spil.32 While O2 species (possible NAs) were identified
351
without any structure information and oxygenated species of NAs (possible oxy-NAs) would
352
have to be removed by solid phase extraction prior to instrument analysis, the abundance
353
variations of NAs suggested that future studies should investigate the use of NA mixtures as a
354
potential source-specific fingerprint for identification purpose. The present study identify O2
355
species and oxygenated products as the responsible pollutants for the differences in profiles
356
between regions during the “4.11” tap water pollution incident in Lanzhou, and clarified these
357
feature to be NAs and oxy-NAs based on the chemical derivatization and MS/MS analysis.
358
The results is consistent with the hypothesis of Corilo’s study,32 and demonstrated that NA
359
mixtures would be a source-specific marker for oil contamination.
360
Numerous studies have shown that NA mixtures were toxic to aquatic organisms such as
361
yellow perch embryos, Japanese Medaka, larval amphibian etc, limited studies is available
362
about effects of NAs on mammalian health and development.46-47 Hepatotoxicity as an acute
363
effect was observed in the rat feed with aqueous solutions containing 550.8 mg/L NAs.47 And
364
expression of cardiac specific markers were significantly up-regulated in mouse embryonic
365
stem cells exposed to NAs at concentrations of 25 µg/L.46 The total concentrations of detected
366
NA isomers ranged from 0.08 to 0.7 µg/L in tap water samples from polluted regions in
367
Lanzhou (Figure 4), which were much less than the effect concentrations of NAs in either rat
368
or mouse stem cells, suggesting the low risks of dietary uptake of the contaminants in the
369
accidental pollution event.
370
Targeted analysis of PAHs and alkyl-PAHs were conducted in the water samples, since
371
residues of PAH mixtures are common proxies to detect oil pollution, oil weathering, and 17
ACS Paragon Plus Environment
Environmental Science & Technology
372
source identification at the oil spill impacted areas.48-51 As showed in SI Table S2, the total
373
concentrations of detected PAHs and alkyl-PAHs were in the range of 10.6-28.7 ng/L and
374
2.8-15.7 ng/L in water samples collected during the pollution and non-pollution periods,
375
respectively. Significantly high concentrations of PAH mixtures observed in water samples in
376
the pollution events compared with those collected during the non-pollution period suggested
377
that oil contamination might be the cause, which is consistent with the results of NA
378
investigations. However, no significant spatial differences could be found for PAH mixtures
379
during the events, and this could be due to that PAH mixtures have many other sources such
380
as forest fires, agricultural burning, coal, and bacteria biosynthesis etc. Thus, compared with
381
suspected target analysis, non-targeted screening would help found the responsible pollutants,
382
which is specifically related to the pollution sources, and contribute to rapidly discriminate
383
pollution sources in accidental pollution events.
384
While benzene is a natural part of crude oil, the presences of benzene in environment is
385
mostly related to the effluent discharges of chemistry industrial, since the greatest use of
386
benzene is as a building block for making plastics, rubber, resins and synthetic fabrics.52 Thus
387
the pollution sources were not clear when benzene, one of the regular monitoring chemicals in
388
tap water, was detected with concentrations about 20 times above the national limit in
389
Lanzhou. It took a long time for the local agency to find an oil leaking site close to the
390
drinking water pipe, but no direct evidences between water samples and pollution sources can
391
be provided based on the government report. In the present study, the detection of NA
392
mixtures, identified by a non-targeted analytical strategy and chemical derivatization,
393
demonstrated the an oil leaking as the major cause of the event because NAs have unique 18
ACS Paragon Plus Environment
Page 18 of 29
Page 19 of 29
Environmental Science & Technology
394
sources for oil contamination, providing direct evidence between water samples and pollution
395
sources. The non-targeted screening by high-resolution MS could potentially help to rapidly
396
discriminate the regional difference between pollution and reference areas and determine the
397
actual pollutants responsible for pollution accidents.
398 399 400 401
Acknowledgments The research is supported by National Natural Science Foundation of China (21177003, 21422701), and National Basic Research Program of China (2015CB458900).
402 403 404
Supplementary Data Text, figures, and tables addressing (1) chemicals and reagents; (2) sample analysis of
405
PAH mixtures; (3) validation plots from permutation tests for non-targeted OPLS-DA analysis;
406
(4) S-plots of OPLS-DA of water samples from polluted and reference regions during the
407
event; (5) Proposed structures of some oxy-NAs; (6) MS/MS spectra of oxy-NAs; (7) MS/MS
408
spectra of oxy-NAs derivartized with DNS; (8) the scores plots of OPLS-DA model for
409
targeted analysis of NAs in water samples during the events and non-pollution period; (9)
410
validation plots obtained from permutation tests for targeted OPLS-DA analysis; (10)
411
structure information of model NA compounds; (11) levels of PAHs and alkyl-PAHs detected
412
in all water samples.
19
ACS Paragon Plus Environment
Environmental Science & Technology
413
REFERENCES
414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455
1. Zhang, X. J.; Chen, C.; Lin, P. F.; Hou, A. X.; Niu, Z. B.; Wang, J. Emergency drinking
2.
3.
4. 5.
6. 7. 8.
9. 10.
11.
12.
13.
14.
15.
water treatment during source water pollution accidents in China: Origin analysis, framework and technologies. Environ. Sci. Technol. 2011, 45, 161−167. Elad, T.; Almog, R.; Yagur-Kroll, S.; Levkov, K.; Melamed, S.; Shacham-Diamand, Y.; Belkin, S. Online monitoring of water toxicity by use of bioluminescent reporter bacterial biochips. Environ. Sci. Technol. 2011, 45, 8536−8544. Lewellyn, G. T.; Dorman, F.; Westland, J. L.; Yoxtheimer, D.; Grieve, P.; Sowers, T.; Humston-Fulmer, E.; Brantley, S. L. Evaluating a groundwater supply contamination incident attributed to Marcellus Shale gas development. Proc. Natl. Acad. Sci. U. S. A. 2015, 112, 6325−6330. Bridges, O. Double trouble: health risks of accidental sewage release. Chemosphere. 2003, 52, 1373−1379. Liu, R. Z.; Borthwick, A. G. L.; Lan, D. D.; Zeng, W. H. Environmental risk mapping of accidental pollution and its zonal prevention in a city. Process Saf. Environ. Protect. 2013, 91, 397−404. China statistic yearbook 2007. China Statistics Press: Beijing, China, 2008. China statistic yearbook 2008. China Statistics Press: Beijing, China, 2009. Pang, L. P.; Wang, W.; Qu, H. Q.; Hu, T.; Zhang, Y. Approach to identifying a sudden continuous emission pollutant source based on single sensor with noise. Indoor Built Environ. 2014, 23, 955−970. Bode, H.; Nusch, E. A. Advanced river quality monitoring in the RUHR basin. Water Sci. Technol. 1999, 140, 145−152. Ren, Z.; Wang, Z. The differences in the behavior characteristics between Daphnia magna and Japanese Madaka in an on-line biomonitoring system. J. Environ. Sci. 2010, 22, 703−708. Guitart, C.; Frickers, P.; Horrillo-Caraballo, J.; Law, R. J.; Readman, J. W. Characterization of sea surface chemical contamination after shipping accidents. Environ. Sci. Technol. 2008, 42, 2275−2282. Martin Peinado, F. J.; Romero-Freire, A.; Garcia Fernandez, I.; Sierra Aragon, M.; Ortiz-Bernad, I.; Simon Torres, M. Long-term contamination in a recovered area affected by a mining spill. Sci. Total Environ. 2015, 514, 219−223. Chandru, K.; Pauzi Zakaia, M.; Anita, S.; Shahbazi, A.; Sakari, M.; Bahry, P. S.; Mohamed, C. A. R. Characterization of alkanes, hopanes, and polycyclic aromatic hydrocarbons (PAHs) in tar-balls collected from the East Coast of Peninsular Malaysia. Mar. Pollut. Bull. 2008, 56, 950−962. Al-Salhi, R. Abdul-Sada, A. Lange, A. Tyler, C. R. Hill, E. M. The xenometabolome and novel contaminant markers in fish exposed to a wastewater treatment works effluent. Environ. Sci. Technol. 2012, 46, 9080−9088. Schymanski, E. L.; Singer, H. P.; Longree, P.; Loos, M.; Ruff, M.; Stravs, M. A.; Vidal, C. R.; Hollender, J. Strategies to characterize polar organic contamination in wastewater: Exploring the capability of high resolution mass spectrometry. Environ. Sci. Technol. 2014, 48, 1811-1818. 20
ACS Paragon Plus Environment
Page 20 of 29
Page 21 of 29
Environmental Science & Technology
456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495
16. Peng, H.; Chen, C.; Saunders, D. M. V.; Sun, J. X.; Tang, S.; Codling, G.; Hecker, M.;
496
27.
497 498 499
17.
18.
19.
20.
21.
22. 23.
24.
25.
26.
Wiseman, S.; Jones, P. D.; Li, A.; Rockne, K. J.; Giesy, J. P. Untargeted identification of oragno-bromine compounds in lake sediments by ultrahigh-resolution mass spectrometry with the data-independent precursor isolation and characteristic fragment method. Anal. Chem. 2015, 87, 10237-10246. Schymanski, E. L.; Singer, H. P.; Slobodnik, J.; Ipolyi, I. M.; Oswald, P.; Krauss, M.; Schulze, T.; Haglund, P.; Letzel, T.; Grosse, S.; Thomaidis, N. S.; Bletsou, A.; Zwiener, C.; Ibanez, M.; Portoles, T.; de Boer, R.; Reid, M. J.; Onghena, M.; Kunkel, U.; Schulz, W.; Guillon, A.; Noyon, N.; Leroy, G.; Bados, P.; Bogialli, S.; Stipanicev, D.; Rostkowski, P.; Hollender, J. Non-target screening with high-resolution mass spectrometry: critical review using a collaborative trial on water analysis. Anal. Bioanal. Chem. 2015, 407, 6237-6255. Xu, X.; Roman, J. M.; Issaq, H. J.; Keefer, L. K.; Veenstra, T. D.; Ziegler, R. G. Quantitative measurement of endogenous estrogens and estrogen metabolites in human serum by liquid chromatography-tandem mass spectrometry. Anal. Chem. 2007, 79; 7813-7821. Chang, H.; Wan, Y.; Naile, J.; Zhang, X. W.; Wiseman, S.; Hecker, M.; Lam, M. H. W.; Giesy, J. P.; Jones, P. D. Simultaneous quantification of multiple classes of phenolic compounds in blood plasma by liquid chromatography-electrospray tandem mass spectrometry. J Chromat. A. 2010, 1217, 506-513. Peng, H.; Hu, K. J.; Zhao, F. R.; Hu, J. Y. Derivatization method for sensitive determination of fluorotelomer alcohols in sediment by liquid chromatography-electrospray tandem mass spectrometry, J Chromat. A. 2013, 1288, 48-53. Hardas, N. R. Adam, R. Uden, P. C. Alkene determination by bromination and gas chromatography with element-selective atomic plasma spectroscopic detection. J. Chromatogr. A. 1999, 844, 249−258. Merlin, M. Guigard, S. E. Fedorak, P. M. Detecting naphthenic acids in waters by gas chromatography-mass spectrometry. J. Chromatogr. A. 2007, 1140, 225−229. Wang, B. L.; Wan, Y.; Gao, Y. X.; Yang, M.; Hu, J. Y. Determination and Characterization of Oxy-Naphthenic Acids in Oilfield Wastewater. Environ. Sci. Technol. 2013, 47, 9545−9554. Wan, Y.; Wang, B. L.; Khim, J. S.; Hong, S.; Shim, W. J.; Hu, J. Y. Naphthenic acids in costal sediments after the Hebei spirit oil spill: a potential indicator for oil contamination. Environ. Sci. Technol. 2014, 48, 4153-4162. Ibanez, M.; Sancho, J. V.; McMillan, D.; Rao, R.; Hernandez, F. Rapid non-target screening of organic pollutants in water by ultraperformance liquid chromatography coupled to time-of-light mass spectrometry. Trac-Trends Anal. Chem. 2008, 27, 481−489. Garcia-Reyes, J. F.; Hernando, M. D.; Molina-Diaz, A.; Fernandez-Alba, A. R.; Comprehensive screening of target, non-target and unknown pesticides in food by LC-TOF-MS. Trac-Trends Anal. Chem. 2008, 26, 828−841. Chen, Y.; Zhang, N.; Ma, J.; Zhu, Y.; Wang, M.; Wang, X. M.; Zhang, Peng. A Platelet/CMC coupled with offline UPLC-QTOF-MS/MS for screening antiplatelet activity components from aqueous extract of Danshen. J. Pharm. Biomed. Anal.. 2016, 117, 178-183. 21
ACS Paragon Plus Environment
Environmental Science & Technology
500
28. Tang Y. N.; Pang, Y. X.; He, X. C.; Zhang, Y. Z.; Zhang, J. Y.; Zhao, Z. Z.; Yi, T.; Chen,
501
H. B. UPLC-QTOF-MS identification of metabolites in rat biosamples after oral administration of Dioscorea saponins: A comparative study. J. Ethnopharmacol. 2015, 165, 127-140. Zhang, H. M.; Li, S. L.; Zhang, H.; Wang, Y.; Zhao, Z. L.; Chen, S. L.; Xu, H. X. Holistic quality evaluation of commercial white and red ginseng using a UPLC-QTOF-MS/MS-based metabolomics approach. J. Pharm. Biomed. Anal. 2012, 62, 258-273. Guo, W. Between preventive supervision and relief supervision: from the perspective of water benzene pollution event in Lanzhou city. Environ. Prot. 2014, 13, 26−29. Mueller, A.; Schulz, W.; Ruck, W. K. L.; Weber, W. H. A new approach to data evaluation in the non-target screening of organic trace substances in water analysis. Chemosphere. 2011, 85, 1211-1219. Corilo, Y. E.; Podgorski, D. C.; McKenna, A. M.; Lemkau, K. I.; Reddy, C. M.; Mashall, A. G.; Rodgers, R. P. Oil spill source identification by principal component analysis of electrospray ionization fourier transform ion cyclotron resonance mass spectra. Anal.Chem. 2013, 85, 9064-9069. Wang, X.; Kasperki, K. L. Analysis of naphthenic acids in aqueous solution using HPLC-MS/MS. Anal. Methods. 2010, 2, 1715-1722. Hindle, R.; Noetheden, M.; Peru, K.; Headley, J. Quantitative analysis of naphthenic acids in water by liquid chromatography-accurate mass time-of-flight spectrometry. J. Chromatogr. A. 2013, 1286, 166-174. Shang, D.; Kim, M.; Haberl, M.; Legadins, A. Development of a rapid liquid chromatography tandem mass spectrometry method for screening of trace naphthenic acids in aqueous environments. J. Chromatogr. A. 2013, 1278, 98-107. Rudzinski, W. E.; Oehlers, L.; Zhang, Y. Tandem mass spectrometric characterization of commercial naphthenic acids and a Maya crude oil. Energy & Fuels.2002, 16, 1178-1185. Han, X. M.; Mackinnon, M. D.; Martin, J. W. Estimating the in situ biodegradation of naphthenic acids in oil sands process waters by HPLC/HRMS. Chemosphere. 2009, 76, 63−70. Barrow, M. P.; Headley, J. V.; Peru, K. M; Derrivk, P. J. Data visualization for the characterization of naphthenic acids within petroleum samples. Energy Fuels. 2009, 23, 2592−2599. Grewer, D. M.; Young, R. F.; Whittal, R. M.; Fedorak, P. M. Naphthenic acids and other acid-extractables in water samples from Alberta: what is being measured? Sci. Total Environ. 2010, 408, 5997−6010. Scott, A. C.; Young, R. F.; Fedorak, P. M. Comparison of GC-MS and FTIR methods for quantifying naphthenic acids in water samples. Chemosphere. 2008, 73, 1258-1264. Watson, J. S.; Jones, D. M.; Swannell, R. P. J.; van Duin, A. C. T. Formation of carboxylic acids during aerobic biodegradation of crude oil and evidence of microbial oxidation of hopanes. Org. Geochem. 2002, 33, 1153-1169. Bataineh, M.; Scott, A. C.; Fedorak, P. M.; Martin, J. W. Capillary HPLC/QTOF-MS for characterizing complex naphthenic acid mixtures and their microbial transformation. Anal.
502 503 504
29.
505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542
30. 31.
32.
33. 34.
35.
36. 37.
38.
39.
40. 41.
42.
22
ACS Paragon Plus Environment
Page 22 of 29
Page 23 of 29
543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576
Environmental Science & Technology
43.
44.
45.
46.
47.
48. 49.
50.
51.
52.
Chem. 2006, 78, 8354−8361. Holowenko, F. M.; Mackinnon, M. D.; Fedorak, P. M. Characterization of naphthenic acids in oil sands waste waters by gas chromatography-mass spectrometry. Water Res. 2002, 36, 2843−2855. Martin, J. W; Han, X. M.; Peru, K. M; Headley, J. V. Comparison of high- and low-resolution electrospray ionization mass spectrometry for the analysis of naphthenic acid mixtures in oil sands process water. Rapid Commun. Mass Spectrom. 2008, 22, 1919−1924. Clemente, J. S.; Prasad, N. G. N.; Mackinnon, M. D.; Fedorak, P. M. A statistical comparison of naphthenic acids characterized by gas chromatography-mass spectrometry. Chemosphere. 2003, 50, 1265−1274. Mohseni, P.; Hahn, N. A.; Frank, R. A.; Hewitt, L. M.; Hajibabaei, M.; Van Der Kraak, G. Naphthenic acid mixtures from oil sands process-affected water enhance differentiation of mouse embryonic stem cells and affect development of the heart. Environ. Sci. Technol. 2015, 49, 10165-10172. Rogers, V. V.; Wickstrom, M.; Liber, K.; MacKinnon, M. D. Acute and subchronic mammalian toxicity of naphthenic acids from oil sands tailings. Toxicol. Sci. 2002, 66, 347-355. Wang, Z. D.; Fingas, M.; Page, D. S. Oil Spill identification. J Chromat. A. 1999, 843, 369-411. Douglas, G. S.; Bence, A. E.; Prince, R. C.; McMillen, S. J.; Butler, E. L. Environmental stability of selected petroleum hydrocarbon source and weathering ratios. Environ. Sci. Technol. 1996, 30, 2332-2339. Boehm, P. D.; Douglas, G. S.; Burns, W. A.; Mankiewicz, P. J.; Page, D. S.; Bence, A. E. Application of petroleum hydrocarbon chemical fingerprinting and allocation techniques after the Exxon Valdez oil spill. Mar. Pollut. Bull. 1997, 34, 599-613. Hong, S.; Khim, J. S.; Ryu, J.; Park, J.; Song, S. J.; Kwon, B. –O.; Choi, K.; Ji, K.; Seo, J.; Lee, S.; Park, J.; Lee, W.; Choi, Y.; Lee, L. T.; Kim, C. -K.; Shim, W. J.; Naile, J. E.; Giesy, J. P. Two years after the Hebei Spirit oil spill: residual crude-derived hydrocarbons and potential AhR-mediated activities in coastal sediments. Environ. Sci. Technol. 2012, 46, 1406-1414. Health Canada. Guidelines for Canadian drinking water quality, guideline technical document benzene, 2009.
577 578 579 580
23
ACS Paragon Plus Environment
Environmental Science & Technology
Page 24 of 29
Table 1. Precursors and MS/MS fragment ions of NAs, and oxy-NAs and their corresponding derivatives with dansyl chloride generated in MS/MS mode of QTOF-MS in extracts of tap water, and the MS/MS spectra with precursor ions of 255, 239 and 281 as shown in Figure 3. MS/MS Compounds
Precursor ion
RT (min)
C18H34O2
281
13.00
C18H36O2
283
13.54
C16H32O2
255
11.20
C12H24O2
199
10.01
C13H20O4
239
4.38
C15H22O4
265
4.57
C14H20O5
267
4.38
C15H22O5
281
4.44
NAs
Oxy-N As
MS/MS of dansyl chloride derivatives
Mass fragment ions
Mass fragment ions
[M-H-CO2]-
[M-H-H2 O-CO2]-
[M+DNS+ H]+
[C12H14NO3S]+
[C12H13N]+
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
221.1188
195.139
177.1283
474.1981
252.0676
171.1044
(-2.1 ppm)
(4.5 ppm)
(2.6 ppm)
(2.3 ppm)
(6.5 ppm)
(-7.1 ppm)
(-2.3 ppm)
265.1437
247.1329
221.1539
203.1432
500.2127
252.0698
171.1039
(-1.1 ppm)
(-2.0 ppm)
(-1.3 ppm)
(-2.0 ppm)
(4.0 ppm)
(1.6 ppm)
(-5.3 ppm)
267.1218
249.1114
223.1316
205.1231
502.1918
252.0684
171.1045
(-5.2 ppm)
(-5.2 ppm)
(-8.1 ppm)
(1.0 ppm)
(3.8 ppm)
(-4.0 ppm)
(-1.8 ppm)
281.1388
263.1289
237.1481
219.1398
516.2032
252.0691
171.104
(-0.4 ppm)
(2.8 ppm)
(-4.2 ppm)
(5.9 ppm)
(-4.6 ppm)
(-1.2 ppm)
(-4.7 ppm)
[M-H]-
[M-H-H2O]-
281.2479
263.2384
(-0.7 ppm)
(3.4 ppm)
283.2635
265.2526
(-0.7 ppm)
(-1.9 ppm)
255.2332
237.222
(3.1 ppm)
(0.8 ppm)
199.1694
181.16
(-2.0 ppm)
(4.4 ppm)
239.1278
Mass errors of fragmentation ions higher than 5 ppm are possible due to the low abundance of the compounds.
24
ACS Paragon Plus Environment
Page 25 of 29
Environmental Science & Technology
581 582
Figure 1.Sampling sites of tap water collected in Lanzhou, China.
583 584
25
ACS Paragon Plus Environment
Environmental Science & Technology
585 586 587 588 589
Figure 2. Multivariate analysis of untargeted profiling of tap water extracts. Classes of PCA score plots and OPLS-DA score plots are from the polluted period (a, c) and the non-pollution period (b, d), respectively.
590
26
ACS Paragon Plus Environment
Page 26 of 29
Page 27 of 29
591 592 593 594 595 596
Environmental Science & Technology
Figure 3. MS/MS spectra of NAs with precursor ions of 255 (a) and 281 (b), oxy-NAs with precursor ions of 239 (c) and 281 (d) and corresponding oxy-NAs derivatives with precursor ions of 474 (e) and 516 (f) in the extracts of tap water. The proposed structures of e and f were shown in SI Figure S3.
597
27
ACS Paragon Plus Environment
Environmental Science & Technology
598 599 600 601 602 603
Figure 4. Boxplots of typical identified markers (CnH2n+ZOx with Z of -8 to 0 and x of 2 to 5) in the tap water from the reference region (R) and polluted region (P) during the events. All of the compounds exhibited statistically significantly higher levels in water samples from the polluted region (p