Subscriber access provided by Queen Mary, University of London
Ecotoxicology and Human Environmental Health
High-throughput Effect-Directed Analysis using downscaled in vitro reporter gene assays to identify endocrine disruptors in surface water Nick Zwart, Shan Li Nio, Corine J Houtman, Jacob De Boer, Jeroen Kool, Timo Hamers, and Marja H. Lamoree Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b06604 • Publication Date (Web): 16 Mar 2018 Downloaded from http://pubs.acs.org on March 20, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 31
Environmental Science & Technology
1
1
High-throughput Effect-Directed Analysis using downscaled in vitro reporter
2
gene assays to identify endocrine disruptors in surface water
3 4
1
1
2
1
3
1
Nick Zwart , Shan Li Nio , Corine J. Houtman , Jacob de Boer , Jeroen Kool , Timo Hamers , Marja H. Lamoree
1
5 6
1
Department Environment & Health, VU University, Amsterdam, The Netherlands 2
7 8
The Water Laboratory, Haarlem, The Netherlands
3
Biomolecular Analysis group, VU University, The Netherlands
9 10
E-mail contact:
[email protected] 11 12
Effect-Directed Analysis (EDA) is a commonly used approach for effect-based identification of endocrine
13
disruptive chemicals in complex (environmental) mixtures. For routine toxicity assessment of e.g. water
14
samples however, current EDA approaches are considered time consuming and laborious. We achieved
15
faster EDA and identification, by downscaling of sensitive cell-based hormone reporter gene assays and
16
increasing fractionation resolution to allow testing of smaller fractions with reduced complexity. The
17
high-resolution EDA approach is demonstrated by analysis of four environmental passive sampler
18
extracts. Downscaling of the assays to 384-well format allowed analysis of 64 fractions in triplicate (or
19
192 fractions without technical replicates) without affecting sensitivity compared to the standard 96-
20
well format. Through a parallel exposure method, agonistic and antagonistic androgen- and estrogen
21
receptor activity could be measured in a single experiment following a single fractionation. From sixteen
22
selected candidate compounds, identified through non-targeted analysis, thirteen could be confirmed
23
chemically and ten were found biologically active of which the most potent non-steroidal estrogens
24
were identified as oxybenzone and piperine. The increased fractionation resolution and the higher
ACS Paragon Plus Environment
Environmental Science & Technology
2 25
throughput that downscaling provides, allows for future application in routine high-resolution screening
26
of large numbers of samples in order to accelerate identification of (emerging) endocrine disruptors.
27 28
Introduction
29
Endocrine disruption is an important endpoint in toxicological and environmental screening as well as
30
the water quality control of the drinking water production process. Endocrine disruptive chemicals
31
(EDCs) like estrogens1 and androgens2 have been detected in the aquatic environment as pollutants. A
32
large portion of EDCs are emitted into the aquatic environment through urban (steroid hormones, flame
33
retardants, plasticizers) or industrial wastewater,3 agricultural runoff4 or deposition after combustion
34
(PAHs).5 Subsequent exposure can lead to disrupted signaling of endogenous hormones. Further liver
35
metabolism can enhance receptor binding potency of (inactive) pollutants and increase the risk of
36
endocrine disruption.6 While well characterized potent EDCs are actively monitored, unknown
37
compounds with endocrine disruptive potency, including their metabolites, transformation products and
38
degradation products, remain to be discovered. The ability to detect and identify relevant and yet
39
unknown EDCs is essential to efforts aimed at reducing their presence in the aquatic environment and
40
reducing human exposure.
41
Cell-based reporter gene assays have been used in Effect-Directed Analysis (EDA) for the identification of
42
(emerging) EDCs in environmental samples.7–9 Via EDA, compounds not analyzed by routine (chemical)
43
analysis are identified based on their biological activity in reporter bioassays. Activity measured by the
ACS Paragon Plus Environment
Page 2 of 31
Page 3 of 31
Environmental Science & Technology
3 44
reporter gene assays in particular fractions collected during chromatographic separation can be
45
correlated to mass spectrometry data. A response in one or more fractions can direct efforts to identify
46
the compound responsible for the observed activity to a limited number of corresponding masses on the
47
mass chromatogram.
48
Reducing fraction complexity through high-resolution fractionation decreases the number of
49
compounds and masses to be identified per fraction, but increases the total number of fractions.
50
Luciferase reporter gene cell lines, while showing high sensitive towards their respective (ant)agonists,
51
are usually performed in a 96-well plate format which limits the number of samples or fractions that can
52
be analyzed simultaneously.
53
This study focused on improvement of the current EDA approach by increasing throughput and
54
resolution to allow for faster identification as a step forward to a more routine application of EDA in
55
future (surface) water quality assessment.
56
Firstly, for high-resolution EDA of endocrine disruptive chemicals, an androgen receptor (AR) (AR-
57
EcoScreen),
58
EcoScreen GR-KO),11 aryl hydrocarbon receptor (AhR) receptor (DR-Luc)12 and estrogen receptor (ER)
59
(VM7Luc4E2, formerly known as BG1Luc4E2; further referred to as ER-Luc)13 reporter gene assay were
60
downscaled from 96- to 384-well plate format. Throughput is further improved by introducing a method
61
for parallel exposure of multiple endpoints with samples or fractions from a single source plate. In
62
addition, a metabolic system was incorporated in the downscaled assays, to allow for formation and
63
detection of active metabolites from inactive or less active pollutants.
64
Secondly, downscaled assays, using the parallel exposure method, were applied in an EDA approach to
65
analyze four passive sampler extracts which were separated by UPLC and collected as either 64 or 192
66
fractions. The mass spectra (recorded in parallel) were analyzed at retention times that correlated with
10
a recently developed AR-EcoScreen glucocorticoid receptor (GR) knockout mutant (AR-
ACS Paragon Plus Environment
Environmental Science & Technology
4 67
active fractions to select masses for identification. A qualitative non-targeted screening was performed
68
and selected candidates were confirmed chemically and biologically.
69
Materials and methods
70
Materials
71
Dulbecco's Modified Eagle Medium/Nutrient Mixture F-12 (DMEM/F12) medium with glutamax, phenol-
72
free DMEM/F12 medium with L-glutamine, low glucose phenol-free DMEM medium, and fetal bovine
73
serum were obtained from Gibco (Eggenstein, Germany), penicillin/streptomycin, G418, hygromycin,
74
zeocin, ATP, co-enzyme A, formic acid, acetonitrile (HPLC grade) and methanol (Chromasolv) from Sigma
75
(Zwijndrecht, The Netherlands), luciferin from Promega (Fitchburg, WI, USA), DTT (dithiothreitol) from
76
Duchefa (Haarlem, The Netherlands) and Aroclor 1254 induced rat liver S9 fraction was obtained from
77
MP Biomedicals (Santa Ana, USA). Water was purified on a Milli-Q Reference A+ purification system
78
(Millipore, Bedford, MA, USA). Reference compounds used for validation of the downscaled test
79
methods and candidate compounds for confirmation of hits were obtained from various suppliers (see
80
Supporting Information Table S1) and were dissolved in DMSO (Acros, Geel, Belgium).
81
Cell culture conditions
82
AR-EcoScreen (CHO-K1), exhibiting residual GR sensitivity, and AR-EcoScreen GR-KO (CHO-K1) cells, with
83
exclusive AR sensitivity, were maintained as described by Satoh et al.10 ER-Luc (MCF7 human breast
84
carcinoma) cells were maintained as described by Rogers and Denison.13 Briefly, cells were cultured at
85
37 °C with 5% CO2 in DMEM/F12 medium (with 10% fetal bovine serum and 1% penicillin/streptomycin),
86
further referred to as culture medium, and sub-cultured twice weekly. DR-Luc cells were maintained and
87
exposed as described in Supporting Information, Section S1.1.
88
Reporter gene assay protocols
ACS Paragon Plus Environment
Page 4 of 31
Page 5 of 31
Environmental Science & Technology
5 89
Reporter gene assays were performed in transparent polystyrene CellStar 96-well plates (655160)
90
(Greiner Bio-One, Alphen aan den Rijn, The Netherlands) (as the standard format to compare against the
91
downscaled format) or in white µclear polystyrene CellStar 384-well plates (781098) (Greiner Bio-One,
92
Alphen aan den Rijn, The Netherlands) (downscaled format) using the same cell lines. To maintain the
93
cell-to-surface-area ratio during seeding and compensate for smaller well size, reaction volumes used in
94
the downscaled format were approximately 3-fold lower compared to the standard format (see
95
Supporting Information Table S2). Potential effects of medium evaporation on the measurement were
96
reduced by filling the outer ring with 100 µL (96-well plates) or two outer rings with 34 µL (384-well
97
plates) sterile milliQ water which resulted in 60 or 240 wells available for measurements, respectively.
98
Prior to exposure, trypsinated cells were resuspended in phenol-free DMEM/F12 L-glutamine (AR-
99
EcoScreen and AR-EcoScreen GR-KO), low glucose phenol-free DMEM (ER-Luc) medium (with 5%
100
charcoal stripped fetal bovine serum), further referred to as AR-EcoScreen or ER-Luc assay medium,
101
respectively, and seeded at 200.000 cells/mL in 100 µL (96-well plates) or 34 µL aliquots (384-well
102
plates). Plates were incubated for 24 hours at 37 °C and 5% CO2. In each experiment (n=1), seeded cells
103
were exposed at t=0 in triplicate to compounds dissolved in 100 µL (96-well plates) or 34 µL assay
104
medium (384-well plates), at a final DMSO concentration of 1 or 5 µL/mL for the AR-EcoScreen (and GR-
105
KO) or ER-Luc cells, respectively, using a single (96-well plates) or 8-channel (384-well plates) manual
106
pipette. Reference compound dilution series were prepared in DMSO and, prior to exposure, diluted to
107
exposure concentrations (see Supporting Information Table S1) in the respective assay medium for each
108
cell type at a final DMSO concentration of 1 or 5 µL/mL for the AR-EcoScreen (and GR-KO) or ER-Luc
109
cells, respectively. In antagonism experiments, cells were additionally exposed to compounds or
110
fractions in the presence of 200 pM DHT in AR-EcoScreen (and GR-KO) or 4 pM 17β-estradiol (E2) in ER-
111
Luc by spiking assay medium with 5 µM DHT and 0.1 µM E2 in DMSO, respectively. Cytotoxicity was
112
measured in the exposed cells by adding resazurin dissolved in PBS at t=22 h leading to a final
ACS Paragon Plus Environment
Environmental Science & Technology
6 113
concentration of 21 nM and measuring fluorescence (λex=530 nm; λem=590 nm) immediately after
114
addition and at t=24 h. Conversion rate of resazurin into resorufin in cells exposed to test substances
115
was compared to the conversion rate in cells exposed to vehicle (DMSO) only. At t=24 h, medium was
116
aspirated and cells were lysed for 10 minutes on an orbital shaker at 700 rpm with 50 µL (96-well plates)
117
or 17 µL lysis mix (25 mM TRIS (pH 7.8), 2 mM DDT, 2 mM 1,2-cyclohexylenedinitrilotetraacetic acid
118
(CDTA), 10% Glycerol and 1% Triton-X100) (384-well plates). Luminescence was measured on a
119
Varioskan luminometer (Thermo Fisher Scientific, Waltham, MA, USA) for one second after injection of
120
100 µL or 34 µL of glow-mix (2 mM Trycin, 1.07 mM C4H2Mg5O14, 2.67 mM MgSO4, 0.1 mM EDTA, 33.3
121
mM DTT, 270 mM Co-enzyme A, 470 mM Luciferin, and 530 mM ATP) followed by quenching of the
122
reaction with 100 µL (96-well plates) or 34 µL 0.1 M NaOH (384-well plates).
123
Biotransformation
124
Prior to exposure of cells seeded on a 384-well plate in the downscaled format, compounds or fractions
125
were incubated for 90 minutes at 37 °C in 50 µL DMEM phenol-free low glucose medium (with a final
126
volume of 3.6% DMSO (v:v) to ensure solubility of the concentrated compounds during metabolism) in
127
96-well plates, with or, as a control, without addition of 1.7 µL S9-mix (300 µL rat liver S9 fraction per
128
mL, 33 mM KCl, 8mM MgCl2∙6H2O, 6.5 mM glucose-6-phosphate, 4 mM NADP, 100 mM sodium
129
phosphate buffer pH 7.4), to the 50 µL reaction volume at a final concentration of 33 µL S9-mix per mL
130
reaction volume (0.2 mg protein per mL reaction mixture), for generation of metabolites. Incubations
131
were performed on single compounds at concentrations from 1.81 to 109 µM (BPA), 0.181 to 181 µM
132
(flutamide) or 1.81 to 181 µM (tamoxifen). After incubation, 216 µL DMEM phenol-free low glucose
133
medium was added to the reactions, reducing DMSO concentrations to 0.7% and S9-mix concentrations
134
to 6.4 µL/mL. Cells seeded on 384-well plates were prepared for exposure by adding 24 µL of their
135
respective assay medium to the aspirated cells. In each experiment (n=1) 10 µL of diluted
136
biotransformation reaction mixtures were added to the cells in triplicate to reach the final volume of 34
ACS Paragon Plus Environment
Page 6 of 31
Page 7 of 31
Environmental Science & Technology
7 137
µL with a maximum DMSO concentration of 0.2% and an S9-mix concentration of 1.9 µL per mL
138
exposure medium.
139
Sample preparation
140
Adsorption-based Speedisk (SD) and partitioning-based silicone rubber (SR) passive samplers were
141
deployed for a period of six weeks between August and October 2014 in the river Meuse at Eijsden and
142
in the effluent stream of an ultra-low loaded activated sludge municipal wastewater treatment plant
143
(WWTP) with 25% industrial contribution serving a population equivalent of approximately 300.000, in
144
the Netherlands. Briefly, sample preparation consisted of dichloromethane extraction of SD and hexane
145
extraction of SR samplers. SD and SR extracts were solvent-exchanged from dichloromethane and
146
hexane, respectively, by evaporation under a flow of nitrogen at room temperature and redissolving the
147
samples in 1:2:3 (v:v:v) MeOH:ACN:H2O to 8.4 SD/mL and 60 g SR/mL, respectively.
148
LC-MS analysis and fractionation
149
Fractionation of SD and SR sample extracts was performed on a Kinetex C18 (100 x 2.1 mm, 1.7 µm
150
particle size) column using an Agilent Infinity 1290 UPLC pump and autosampler. Extracts were injected
151
(10 µL) at a flowrate of 250 µL/min in 80% mobile phase A (100% H2O + 0.1% formic acid) and 20%
152
mobile phase B (100% ACN + 0.1% formic acid). The solvent gradient increased to 80% mobile phase B
153
over 15 minutes and was subsequently kept as such for 13 minutes. Post-column, the flow was split in a
154
9:1 ratio on a Quicksplit adjustable flow splitter (ASI, Richmond, CA, USA) with 9 parts being diverted to
155
a nanofraction collector and 1 part to a microTOF II time-of-flight mass spectrometer (Bruker Daltonics,
156
Billerica, MA, USA). The MS was equipped with an ESI source set to positive mode and scanned masses
157
from 50 m/z to 3000 m/z at 10 Hz. Corona and capillary voltages were set to 500 and 4500 V
158
respectively. Nebulizer pressure was kept at 2 bar and nitrogen drying gas flow was kept at 6 L/min.
159
Exposure of fractionated extracts
ACS Paragon Plus Environment
Environmental Science & Technology
8 160
In each experiment (n=1), sample fractions were collected in either 96 (64 fractions collected at 26
161
second intervals) or 384-well plates (192 fractions collected at 9 second intervals) filled with 10 µL or 4
162
µL 10% DMSO in milliQ water, respectively, as keeper to increase recoveries.14 Collected fractions were
163
dried in a Centrivap concentrator (Labconco Corp., Kansas City, MO, USA) for 5 hours at 25°C and
164
redissolved in 50 µL or 12 µL ER-Luc assay medium supplemented with 3.6% DMSO added to improve
165
solubility of compounds, in 96- or 384-well plates respectively, for 10 minutes at 700 rpm. Redissolved
166
fractions were diluted with 216 µL or 50 µL ER-Luc assay medium, lowering the DMSO concentration to
167
0.7% (considering potential residual DMSO used as keeper negligible), in 96- or 384-well plates
168
respectively. Cells seeded on 384 well plates in the downscaled format were prepared for exposure to
169
fractions by aspirating the medium and adding 24 µL AR-EcoScreen assay medium to AR-EcoScreen (and
170
GR-KO) cells or 24 µL ER-Luc assay medium with 0.43% DMSO to ER-Luc cells. Cells were exposed to a
171
single concentration by adding 10 µL of the redissolved fraction to prepared cells, in triplicate for
172
measuring 64 fractions or in a single well for measuring 192 fractions, using a digital stepper- or manual
173
8-channel pipette. This resulted in a final DMSO concentration of 0.2% (2 µL/mL) in AR-EcoScreen (and
174
GR-KO) and 0.5% (5 µL/mL) in ER-Luc cells during exposure compared to 0.1% and 0.5% DMSO during
175
exposure, respectively, described in in the reporter gene assay protocol. As a result from the addition of
176
10 µL dissolved fraction in ER-Luc assay medium to 24 µL AR-EcoScreen assay medium, AR-EcoScreen
177
(and GR-KO) cells were exposed in 29.4% ER-Luc and 70.6% AR-EcoScreen assay medium. From each
178
fraction plate, multiple seeded 384-well plates were exposed to measure different endpoints in parallel.
179
Reference compound dilution series prepared in DMSO were diluted in the same assay medium
180
composition and at the same DMSO concentration at which cells were exposed to fractions. Cells were
181
exposed, in triplicate, to reference compounds by adding 34 µL of the diluted compounds to aspirated
182
cells.
183
Data analysis
ACS Paragon Plus Environment
Page 8 of 31
Page 9 of 31
Environmental Science & Technology
9 184
Bioassay results were analyzed in Prism 5.04 (Graphpad Software Inc, San Diego, CA). For each serial
185
dilution data set, D'Agostino-Pearson test was used to test data normality, and Levene’s test to test
186
homogeneity of variance (significance P < 0.05). Dose response curves of reference compounds and
187
candidate compounds were fitted with a four parametric logistic function [Y=A+(B-A)/(1+(x/C)^D)],
188
where A and B denote minimal and maximal response respectively, C is the EC50 or IC50, D is the
189
hillslope and x represents the tested concentration. Significant differences (P