Online Corrosion Monitoring in a Postcombustion CO2 Capture Pilot

Apr 20, 2015 - real-time corrosion monitoring, SmartCET, is presented and compared with ... tests, the use of an online corrosion monitoring tool will...
1 downloads 0 Views 4MB Size
Subscriber access provided by NEW YORK UNIV

Article

Online Corrosion Monitoring in a Postcombustion CO2 Capture Pilot Plant and its Relation to Solvent Degradation and Ammonia Emissions. Purvil Khakharia, Jan Mertens, Arjen Huizinga, Severine De Vroey, Eva Sanchez Fernandez, Sridhar Srinivasan, Thijs J. H. Vlugt, and Earl Goetheer Ind. Eng. Chem. Res., Just Accepted Manuscript • DOI: 10.1021/acs.iecr.5b00729 • Publication Date (Web): 20 Apr 2015 Downloaded from http://pubs.acs.org on April 25, 2015

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Industrial & Engineering Chemistry Research is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

Online Corrosion Monitoring in a Postcombustion CO2 Capture Pilot Plant and its Relation to Solvent Degradation and Ammonia Emissions. Purvil Khakharia a*, Jan Mertens b, Arjen Huizinga a, Séverine De Vroey b, Eva Sanchez Fernandez a, Sridhar Srinivasan d, Thijs J.H. Vlugt c, Earl Goetheer a a

TNO, Leeghwaterstraat 46, 2628CA, Delft, The Netherlands b

Laborelec, Rodestraat 125, 1630 Linkebeek, Belgium

c

TU Delft Process & Energy Department, Leeghwaterstraat 39, 2628CB, Delft, The Netherlands

d

Honeywell Process Solutions, 11201 Greens Crossing #700, Houston, Texas 77067, USA * Corresponding author: Tel.: +31 888664543, E-mail address: [email protected]

KEYWORDS: Corrosion, Online Real-Time Monitoring, Ammonia emission, metals, Postcombustion CO2 capture pilot plant, Solvent Degradation

ACS Paragon Plus Environment

1

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 35

ABSTRACT: Corrosion in amine treating plants is known to cause integrity failures, plant shutdown, costly repairs, etc. The use of an amine treatment system for Postcombustion CO2 Capture brings additional challenges in terms of the flue gas quality, flue gas composition, operating conditions, scale of operation, etc. These differences are expected to have a significant impact on the overall well-being of the plant and the maintenance strategy over its lifetime. The degradation of solvent, by oxidative and thermal degradation pathways, leads to the formation of various degradation products which are known to be corrosive. The oxidative degradation of amine leads to the formation of ammonia which can be emitted to the atmosphere in the treated flue gas stream. This study aims at verifying the inter-relation between: (1) solvent degradation, (2) corrosion, and (3) NH3 emissions, based on two test campaigns of over 1500 operating hours, in a CO2 capture pilot plant. An on-line tool for real-time corrosion monitoring, SmartCET, is presented and compared with offline corrosion coupon. The different process and operating conditions such as the change in the flue gas composition, start-up and shutdown, and solvent replacement were correlated with the variations in the corrosion parameters (general corrosion rate, pitting factor and corrosion mechanism indicator (CMI)), for both campaigns. The three parameters showed only a small increase for most part of both the campaigns (> 75 days), and followed a similar trend. However, during both the campaigns, a rapid increase of all the three parameters was observed. In one of the campaigns, the three parameters increased by about two orders of magnitude in a time period of about only 20 days, which points towards an autocatalytic out of control solvent chemistry. The common characteristic before the onset of autocatalytic solvent chemistry, is the restart-up of the pilot plant after an extended period of shutdown. Based on these tests, the use of an online corrosion monitoring tool will enable longterm steady state operation of a full scale Postcombustion CO2 capture plant.

ACS Paragon Plus Environment

2

Page 3 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1. INTRODUCTION CO2 capture and storage from flue gas is a promising technique to reduce the total world CO2 emissions and thus help mitigate climate change.

1,2

An absorption-desorption based process for

acid gas removal has been widely used in applications such as natural gas treatment, refineries, etc.

3

Typically, alkanolamines such as monoethanolamine (MEA), diethanolamine (DEA),

methyldiethanolamine (MDEA), 2-amino-2-methyl-1-proponal (AMP), and other amines such as piperazine and their blends are used for acid gas removal. 3,4 A reactive absorption based process is considered to be the first choice for a Postcombustion CO2 Capture (PCCC) plant.

2,5–7

The

application of amine treatment in a PCCC plant needs further attention due to the following differences as compared to previous applications, namely: (1) CO2 partial pressure in the range of 0.03-0.15 bar as compared to 8-80 bar, (2) presence of oxygen (6-10 vol. %) as compared to almost no O2 (< 0.5 vol. %), and c) higher CO2 content in the lean stream leaving the stripper (e.g. 0.2 as compared to 0.1 mol CO2/mol amine).

6,8

These differences can potentially lead to

increased corrosion. Corrosion of amine plants has been widely reported based on field studies. 9 The different types of corrosion observed in CO2 capture applications are general corrosion, stress corrosion cracking, hydrogen damage, crevice corrosion, pitting corrosion, erosion-corrosion, etc.

10,11

Monoethanolamine (MEA), 30 wt. % aq., is one of the most widely used amine for CO2 capture and therefore, the focus of this study. MEA, like other amines, is not an intrinsically corrosive solvent, however, when it absorbs acid gases such as CO2 and H2S it can become corrosive.

11

The presence of oxygen and flue gas impurities such as fly ash, SOx, and NOx can degrade the amine and form degradation products which are corrosive. 12–16 Solvent degradation can occur by two routes, namely: (1) oxidative degradation, caused by the dissolved oxygen in the solvent,

ACS Paragon Plus Environment

3

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 35

and (2) thermal degradation, caused by the high temperature in the stripper in the presence of CO2.

3,17

The different parameters that have been studied for their impact on the extent and rate

of solvent degradation are oxygen partial pressures, temperature, CO2 loading, concentration of amines, presence of metals, etc. 15,18–24 Oxidative degradation of the solvent forms products such as oxalic, glycolic, formic, and acetic acid, which are in a salt form. These salts cannot be regenerated thermally and are thus, called Heat Stable Salts (HSS).

25

Oxidative degradation of

MEA produces ammonia (amongst other degradation products) and it is well understood from lab scale experiments and has also been observed in pilot plant studies. 17,18,26–29 Being extremely volatile, ammonia is emitted into the atmosphere in the treated flue gas stream. Many of the degradation products of amines are known to be corrosive. 22,30,31 Several corrosion studies have been performed at laboratory and pilot plant scale with different solvents and materials. The laboratory scale studies used electrochemical measurements at different temperatures, CO2 loadings, oxygen content, gas phase impurities such as SO2 and NO2.

32–35

12,36–38

The

Corrosion has been evaluated at several pilot plants using MEA and other solvents.

process equipment that are typically vulnerable to corrosion include columns (absorber and stripper), amine heat exchanger, regenerator and reclaimer. 13 Typically, coupons are installed at different locations in the pilot plant and their weight loss is translated into corrosion rate as per standard norms, such as ISO 8407 and ASTM G1-03. The different materials that are used in a process equipment include carbon steel, stainless steel 304L, stainless steel 316L, polymers such as polypropylene, polyvinyldiene fluoride (PVDF), ethylene propylene diene monomer (EPDM) rubbers and composites such as fibre reinforced polymers (FRP). These materials are tested for their susceptibility to corrosion. Corrosion of equipment can lead to downtime, cost of repair and

ACS Paragon Plus Environment

4

Page 5 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

maintenance, structural modifications, etc. Therefore, corrosion should be kept to a minimum to keep the plant in stable operation for long periods of time. An inter-dependence between solvent degradation, corrosion and NH3 emissions is expected as shown in Figure 1. However, no information is available in the literature about the existence and nature of this inter-dependence. There exists a direct relation between solvent degradation and ammonia emissions, as well as, solvent degradation and corrosion. Although intuitive, no experimental evidence exists for a direct correlation of corrosion with ammonia emissions. Recently, an auto-catalytic behaviour of solvent in terms of the ammonia emission and solvent metal content has been pointed out from long term operation of a pilot plant using 30 wt. % MEA as the amine solvent without a reclaimer.

39

This behaviour can be expected based on the

chemistry but, has never been observed in any lab scale experiments. This implies, either the lab scale experiments are not representative enough of a typical PCCC process or the duration of experiments were too short to observe this effect. Moreover, based on classical corrosion coupon technique, the corrosion behaviour is known only towards the end of a test and no information exists about the corrosion behaviour during operation. The objective of this study was to verify the inter-relation between the three parameters; solvent degradation, corrosion and NH3 emissions from pilot plant tests. Furthermore, an on-line tool for corrosion monitoring is presented. The results presented here are part of 2 pilot plant campaigns conducted over successive years: 2011 (Campaign 1) and 2012 (Campaign 2). For both the pilot plant campaigns, MEA (30 wt. %) was used as the CO2 capture solvent. In section 2, the details on the pilot plant and the on-line monitoring tool are mentioned. In section 3, firstly the major events, overview of process conditions and the duration of the two campaigns, is presented. During both the campaigns, the correlation of the three parameters was verified. A period of very

ACS Paragon Plus Environment

5

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 35

high ammonia emissions, severe corrosion and solvent degradation was observed. This was attributed to auto-catalytic degradation mechanism occurring in the solvent.

NH3

Corrosion

Solvent Degradation

Figure 1. Inter-relation of corrosion, solvent degradation and ammonia emission. Solid lines indicate proven correlation. Solvent degradation causes corrosion which leads to further degradation of the solvent. Therefore, they are linked by a double-headed arrow. Solvent degradation leads to the formation of ammonia, and not vice-versa. Therefore, their relation is linked by a single-headed one-directional arrow. The dashed line between corrosion and ammonia indicate no experimental evidence of a direct relation.

ACS Paragon Plus Environment

6

Page 7 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

2. TEST EQUIPMENT AND METHODOLOGY 2.1 CO2 Capture Pilot Plant The tests were performed at TNO’s Postcombustion CO2 capture pilot plant at Maasvlakte, The Netherlands. It receives part of the flue gas stream from E.ON’s coal fired power plant. The pilot plant can handle a maximum of 1210 m3 STP/h (STP; 0°C and 101.325 kPa) flue gas and captures a maximum of 6 tons CO2 per day. A schematic representation of the pilot plant is shown in Figure 2.

Figure 2. Schematic diagram of the CO2 capture pilot plant indicating the measurement locations of the FTIR analyser for the on-line monitoring of NH3 and the online corrosion monitoring probe. The water wash section is within the absorber tower but, shown as a separate unit for

ACS Paragon Plus Environment

7

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 35

better visualisation. The capture plant is a typical absorber-desorber system and has been described in literature. 28,29

The flue gas undergoes pre-treatment to remove SOx from the flue gas stream by scrubbing the gas with soda (aqueous sodium carbonate) and is also cooled to about 40 °C. After pre-treatment, the flue gas enters the CO2 absorption tower which has a total height of 23 m and a diameter of 0.65 m and includes (1) four absorption beds (each 2 m high) with random packing of IMTP 50, (2) water wash section (2 m) with structured packing of Mellapak 250 Y, and (3) demister to remove entrained droplets bigger than 10 µm. The stripper tower is about 15 m high, with two beds each of 4 m with random packing of IMTP 50. In the desorber, the reboiler heats up the absorption liquid to strip CO2 typically at a temperature of 120 °C and a pressure of 1.9 bar. It is important to note that there was no reclaiming section in the pilot plant. The total solvent inventory during operation was ca. 2500 L and varies according to the water balance in the system. The water balance was maintained in the pilot plant, by varying the temperature of the treated flue gas leaving the water wash and addition of demineralised water in the stripper sump. Typically, pure MEA was added periodically to achieve the required solvent strength. However, no solvent bleed was performed. The principal materials of the pilot plant are austenitic stainless steel (304L and 316L). The total surface area of the pilot plant in contact with liquid is ca. 1255 m2, mainly from the packing surface.

ACS Paragon Plus Environment

8

Page 9 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

2.2 Corrosion Monitoring 2.2.1 Online Corrosion Monitoring Real-time online corrosion monitoring was achieved through Honeywell’s SmartCET® realtime measurement system.

40

SmartCET uses electrochemical measurements in order to

characterize the corrosion behaviour. Electrochemical methods provide a sensitive and rapid means of assessing corrosion behaviour of metallic materials.

41

The corrosion rate is obtained

from electrochemical measurements designed to evaluate the corrosion current originating from the oxidation of the metal. The nature of the measurements requires an ionically conducting medium such as water or a molten salt, between the electrodes. SmartCET is designed to operate with three identical electrodes as the electrochemical sensor array. These three electrodes can be of various geometries and sizes depending on the particular application. They are incorporated into a corrosion “probe”, which performs the functions of providing mechanical support, electrically insulates the electrodes from each other and the probe body, and allows access into process fluids which may be at elevated temperatures and pressures. The electrodes perform different functions, and are designated as the Working, Reference and Auxiliary electrode. A finger probe type SmartCET sensor configuration as shown in Figure 3 was used in the test.

ACS Paragon Plus Environment

9

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 10 of 35

Figure 3. Finger probe configuration of the SmartCET sensor used in the test. (Honeywell Smart CET 5000). Depending on the type of the probe, its length can be in the range of 15-30 cm. The current flow is measured and analysed using several different techniques: linear polarisation resistance, electrochemical noise, and superficial capacitance measurements. This yields the following four output variables: - General corrosion rate (µm/year) of the electrode material in the tested conditions - B-value or Stern Geary Constant, measured in mV - Pitting factor; a dimensionless quantity indicating the occurrence of localized corrosion and the overall stability of the corrosion process. 42 - Corrosion Mechanism Indicator (µF/cm2); a qualitative indicator to identify the presence and type of surface films. One of the most susceptible part to corrosion is the hot lean zones which is the outlet of the stripper and thus, the coupon and the probe were installed at the outlet of the stripper prior to the start of the campaign (see Figure 1). 9,13 The material of the probe was SS 316L and SS 304L in campaign 1 and 2, respectively.

ACS Paragon Plus Environment

10

Page 11 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

2.2.2 Offline Corrosion Monitoring During both test campaigns, a corrosion coupon was installed in parallel to the on-line corrosion monitoring at the same location to validate the results of online corrosion monitoring. The corrosion rate and mechanisms were evaluated by visual examination and by weight loss measurements (according to ISO 8407 and ASTM G1-03).

2.3 FTIR A FTIR analyser (GASMET CX 4000) was used to analyse gas phase components. A trace heated line at 180 °C is used to sample the gas. Further detailed information on the FTIR and its application in PCCC plants can be found in literature. 27,28,43,44

2.4 ICP-MS ICP-MS (Inductively Coupled Plasma Mass Spectrometry) was used for determining the solvent metal content of elements such as Fe, Ni, Cr, and Mn. 45

ACS Paragon Plus Environment

11

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 35

3. RESULTS AND DISCUSSION The main events and process parameters are discussed for both campaigns. The trends in online corrosion monitoring i.e. general corrosion rate, CMI and pitting factor and their relation to specific events are discussed for Campaign 1 and 2. The online corrosion monitoring is then compared with the offline corrosion coupons results. Finally, the inter-dependence of corrosion, solvent degradation and ammonia emissions is presented.

3.1 Overview of Campaigns In order to understand the state of the solvent in the pilot plant, it is important to have an overview of the operating conditions and events during the two campaigns. In this section, the events during the campaigns are discussed in detail and will aid in the discussion of the results. The operating hours are defined as the time during which there was flow of both flue gas and the solvent. 3.1.1 Campaign 1 The duration of pilot plant campaign 1 was about 149 days and a total of ca. 2200 operating hours as shown in Figure 4. Several tests were carried out and the entire campaign can be divided into four continuous operation runs; Period 1 from day 0 to day 57, Period 2 from day 79 to day 94, Period 3 from day 108 to day 128, and Period 4 from day 135 to day 149. The pilot plant was not in operation in between the continuous operation periods. During shutdowns, the solvent was stored in the pilot plant itself (absorber and stripper sump) in absence of any additional inert gas blanketing. During the 1st, 3rd, and 4th operational period, the CO2 and O2 content in the flue gas were about 13 vol.% and 7 vol. %, respectively. The flue gas contained 4 vol. % and 17 vol. % of

ACS Paragon Plus Environment

12

Page 13 of 35

CO2 and O2, during period 2. The flue gas composition was altered in order to mimic natural gas combustion derived flue gas by mixing the flue gas with ambient air. It is important to note that the resulting gas would be under saturated with water. Corrosion monitoring was performed for period 3 and 4. The same solvent was used from day 0 until day 128 after which, the entire solvent inventory was completely replaced.

2500

2000

Operation hours

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1500

1000

Period 3

Period 2

Period 1

Period 4

500

0 0

10

20

30

40

50

60

70

80

90

100 110 120 130 140 150

Day Figure 4. Operation hours during campaign 1 indicating the four periods of continuous operation. Typical conditions in the lean solvent stream are shown in Table 1. The conditions were changed either based on a pre-decided test plan or to counter act upset conditions of the flue gas flow rate, composition, amine strength, etc. Typical values indicate the conditions most commonly used during the campaign.

ACS Paragon Plus Environment

13

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 35

Table 1. Operating conditions as measured in the lean solvent stream. The temperature of the stream is measured at the location of the online monitoring probe, while the remaining parameters are located downstream after the lean solvent cooler. Parameter

Typical (Range)

Solvent flow rate

3 (2.5-6.5) ton/h

pH

10.0 (9.5-10.5)

Temperature

120 (114-121) (°C)

CO2 loading

0.56 (0.21-1.44) (mol CO2/L)

3.1.2 Campaign 2 The duration of Campaign 2 was for ca. 140 days and a total of about 1700 operation hours as shown in Figure 5. Several tests were carried out and the entire campaign can be divided into 3 operational periods; Period 1 from day 0 to day 50, Period 2 from day 65 to day 80 and Period 3 from day 85 to day 140. During period 1, the pilot plant was operated intermittently. This was followed by a shutdown of 2 weeks. The solvent was stored in the pilot plant during the intermittent operation period and shutdown. The pilot plant was in continuous operation for 2 weeks during period 2. The solvent was completely replaced thereafter, and from day 85 onwards, during period 3, the pilot plant was in continuous operation till the end of the campaign. The typical CO2 and O2 content in the flue gas was ca. 13 vol. % and 7 vol. %. Corrosion monitoring was performed for the entire time period of the campaign.

ACS Paragon Plus Environment

14

Page 15 of 35

1800 1600 1400

Operation hours

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1200 1000

Period 2 Continous operation

Period 1 Intermittent operation

800

Period 3 Solvent replacement and continuous operation

600 400 200 0 0

10

20

30

40

50

60

70

80

90

100 110 120 130 140

Day Figure 5. Operation hours during campaign 2 indicating the three periods of operation and its nature. Typical conditions in the lean solvent stream are shown in Table 2. The lean CO2 loadings were higher than for campaign 1 due to slightly different operating conditions of the stripper.

Table 2. Operating conditions as measured in the lean solvent stream. The temperature of the stream is measured at the location of the online monitoring probe, while the remaining parameters are located downstream after the lean solvent cooler.

ACS Paragon Plus Environment

15

Industrial & Engineering Chemistry Research

Parameter

Typical value (Range)

Solvent flow rate

3.2 (3.2-6) ton/h

pH

8.9 (8.5-10.8)

Temperature

120 (118-121) (°C)

CO2 loading

1.3 (0.72-1.72) mol CO2/L

3.2 General Trends in Online Corrosion Measurements 3.2.1 Campaign 1

1600 1400

General Corrosion rate/ [µm/y]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 35

1200 Day 115:Solvent make-up

1000 800

Day 128:Complete solvent replacement

600 Day 108:Start of operation

400 200 0 100

105

110

115

120

125

130

135

140

145

150

Days

ACS Paragon Plus Environment

16

Page 17 of 35

Figure 6. Corrosion rate during the pilot plant Campaign 1, specifically period 3 and 4. The solid line represents the trend in the measurements.

2.5

Day 115:Solvent make-up

2.0

CMI / [µF/cm2]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1.5 Day 108:Start of operation

Day 128:Complete solvent replacement

1.0

0.5

0.0 100

105

110

115

120

125

130

135

140

145

150

Days

Figure 7. CMI during the pilot plant Campaign 1, specifically period 3 and 4. The solid line represents the trend in the measurements.

ACS Paragon Plus Environment

17

Industrial & Engineering Chemistry Research

0.8

0.6

Pitting factor

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 35

Day 128:Complete solvent replacement Day 108:Start of operation

0.4 Day 115:Solvent make-up 0.2

0.0 100

105

110

115

120

125

130

135

140

145

150

Days Figure 8. Pitting factor during the pilot plant Campaign 1, specifically period 3 and 4. The pitting factor is lower when the pilot plant is in operation.

The measured general corrosion rate, CMI and pitting factor during period 3 and 4 of campaign 1 are as shown in Figures 6,7, and 8, respectively. During days 94 to 108, stagnant used solvent from previous operation periods (1 and 2) was in the plant. The low corrosion rate and CMI factor during this period indicate the characteristics of a “passive” system as shown in Figure 6 and Figure 7. The corrosion rate increases as the operation of the pilot plant is started on day 108. This gives rise to an increase in the CMI to values larger than 0.02µF/cm². On day 110, on

ACS Paragon Plus Environment

18

Page 19 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

further operation the corrosion rate and CMI increases rapidly and reaches a maximum value of ca. 800 µm/y and 1µF/cm², respectively. On day 115, about 400 L of pure MEA is added in to the pilot plant which temporarily reduces the corrosion rate and CMI. This effect is expected as the total volume increases which leads to dilution of the corrosive products by about 16 %. However, in order to maintain the total solvent inventory, water is made to evaporate from the plant, leading to further concentration of the corrosive products and increase in the corrosion rate and CMI. The average corrosion rate reaches a maximum of 600 µm/y, while the maximum average CMI value is 0.7µF/cm². The pilot plant was cleaned and replaced with fresh solvent on day 128. Thereafter, the corrosion rate then reduces back to the initial values to below 20 µm/y, with temporary peaks on few days. However, the CMI value remains in the range of 0.3-0.5 µF/cm². The pitting factor remains low when the pilot plant is in operation and increases when the pilot plant is not in operation. The corrosion mechanism is expected to be general corrosion. The average corrosion rate measured during Campaign 1 was ca. 0.13 mm/y. The associated corrosion resistance belongs to the “good” category (i.e. 0.1-0.5 mm/y).

42

The corrosion

resistance after solvent replacement (~day 123) belongs to the “outstanding” category (i.e. < 25 µm/y).

42

The corrosion coupon placed at the hot lean solvent stream was lost and thus, the

corrosion rate could not be calculated. This is likely due to the improper installation of the coupon holder.

ACS Paragon Plus Environment

19

Industrial & Engineering Chemistry Research

3.2.2 Campaign 2

30 Period 3 Continuous operation

Period 1 Intermittent operation

General Corrosion rate / [µm/y]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 35

25

20

15

Day 85:Complete solvent replacement

10

5

0 0

10

20

30

40

50

60

70

80

90

100 110 120 130 140

Days Figure 9. Corrosion rate during the pilot plant Campaign 2. The pilot plant was operated intermittently in period 1, while it was operated continuously during period 3.

ACS Paragon Plus Environment

20

Page 21 of 35

2.0 Period 3 Continuous operation

Period 1 Intermittent operation

1.5

CMI / [µF/cm2]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

Day 85:Complete solvent replacement

1.0

0.5

0.0 0

10

20

30

40

50

60

70

80

90 100 110 120 130 140

Days Figure 10. CMI during the pilot plant Campaign 2. The pilot plant was operated intermittently in period 1, while it was operated continuously during period 3.

ACS Paragon Plus Environment

21

Industrial & Engineering Chemistry Research

1.4 Period 1 Intermittent operation

1.2

Period 3 Continuous operation

1.0

Pitting factor

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 35

Day 85:Complete solvent replacement

0.8

0.6

0.4

0.2

0.0 0

10

20

30

40

50

60

70

80

90

100 110 120 130 140

Days Figure 11. Pitting factor during the pilot plant Campaign 2. The pilot plant was operated intermittently in period 1, while it was operated continuously during period 3.

Figures 9, 10, and 11 shows the measured general corrosion rate, CMI and pitting factor, respectively during campaign 2. The corrosion rate and CMI increases when the pilot plant is in operation during the intermittent operation of period 1. The corrosion rate is in the range of 1025 µm/y, while the CMI is in the range of 1.3-1.5 µF/cm2. When the pilot plant is started on day 65 for continuous operation period 2, a peak in both the corrosion rate and CMI is observed and continues to decrease in time until day 74. From day 74 till day 80, when the pilot plant is

ACS Paragon Plus Environment

22

Page 23 of 35

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

stopped, both parameters show a rapid increase. Once the solvent is replaced, both parameters continue to decrease in time on continuous operation until the end of the campaign. The change in corrosion mode could not be clearly explained but, it is probably due to solvent state modifications associated with intermittent operation and/or solvent/demin water additions. The general corrosion rate and the pitting factor are globally stable and constant during the entire campaign, with the exception of intermittent start and stop of the pilot plant. During those stops, the corrosion rate is lower than the normal operation while the pitting factor is higher (the pitting factor is by definition inversely proportional to the general corrosion rate). The measured general corrosion rate is ca. 4 µm/y which corresponds to an outstanding corrosion resistance (