PBA Copolymers by Combined SEC

Sep 16, 1999 - of two random copolymers, poly(methyl methacrylate)/polybutyl acrylate (PMMA/PBA) obtained at high and low conversions, respectively, w...
0 downloads 0 Views 273KB Size
Macromolecules 1999, 32, 7015-7022

7015

Bivariate Distribution in PMMA/PBA Copolymers by Combined SEC/NMR and SEC/MALDI Measurements Maurizio S. Montaudo Istituto per la Chimica e la Tecnologia dei Materiali, Polimerici, Consiglio Nazionale delle Ricerche, Viale A. Doria, 6-95125 Catania, Italy

Giorgio Montaudo* Dipartimento di Scienze Chimiche, Universita´ di Catania, Viale A. Doria, 6-95125 Catania, Italy Received March 2, 1999; Revised Manuscript Received June 21, 1999

ABSTRACT: High conversion copolymers may experience a strong variation in composition as a function of monomer conversion, and since the compositional heterogeneity of copolymers varies as the size of the chains grows, this poses a problem in determining the bivariate distribution of masses and composition in copolymers. Although several methods have been proposed to determine bivariate distributions, relatively little data are available on this important aspect of copolymer characterization, perhaps because of the complexity of the methods available up to the present time. We propose here a generally applicable method to determine bivariate distribution of masses and composition in copolymers. SEC fractionation of two random copolymers, poly(methyl methacrylate)/polybutyl acrylate (PMMA/PBA) obtained at high and low conversions, respectively, was used to collect nearly monodisperse fractions that allowed the computation of the corresponding molar masses (by matrix-assisted laser desorption ionization mass spectrometry, MALDI, measurements) and of compositions (by NMR measurements) for the two copolymers. Bivariate distribution maps were derived by combining SEC/NMR and SEC/MALDI data with Stockmayer’s theoretical distribution to estimate the composition distribution of each fraction.

Introduction The structural and molecular analysis of copolymers is a difficult problem that often cannot be easily dealt with by analyzing the intact copolymer, and therefore much effort has been put into the task of converting the SEC traces into molar masses (MM) of copolymers.1-7 Multiple detectors and SEC/light-scattering techniques may provide a solution to the problem, but difficulties remain.2,3,5 In fact, the multiple detector approach requires calibration of the detectors and of the column set for each homopolymer. The use of a light-scattering detector for copolymers encounters difficulties connected with its low sensitivity for low molar mass molecules and with the determination of the copolymer concentration in non homogeneous materials, where the chain dimensions of copolymers may not depend on the molar mass in a linear way.2,3 Being able to discriminate among different masses and possessing a remarkably high sensitivity, the matrix-assisted laser desorption ionization mass spectrometry (MALDI) detector does not suffer these limitations8-10 and, coupled with analytical size exclusion chromatography (SEC), MALDI was found to give mass spectra with average MM values in excellent agreement with those obtained by conventional techniques.8-10 When MALDI was used as the detector in the SEC fractionation of polydisperse copolymer samples, it became possible to determine the molar mass distributions and the hydrodynamic interactions in copolymers,11 and this method might also lead to an estimate of the molecular dimensions in copolymers. Furthermore, the composition of copolymers varies as the size of the chains grows, and this poses the problem

to determine the so-called “bivariate distribution” with respect to masses and composition.12-15 Information on the bivariate distribution is particularly important in high conversion copolymers, which may experience a strong variation in composition as a function of monomers conversion. Various methods have been proposed to determine their compositional heterogeneity. One possibility is to use a multiple detectors SEC apparatus,6 modifying the classical SEC configuration by adding, for instance, an UV detector in series after the standard refractive index (RI) detector. Thus, it has been shown that it is possible to measure the variation of composition in styrene/butadiene copolymers.6 However, this method cannot be applied when both components possess UV absorption (or both do not absorb in the UV). Another method uses a “chromatographic cross fractionation” apparatus,16-20 where macromolecules having different composition are separated in a first chromatographic column, and a second column elutes, at different times, macromolecules having different sizes.16-20 Using an FTIR detector coupled to the SEC apparatus, it has been possible to measure the variation of composition in ethylene/vinyl acetate copolymers.17 However, scant data on bivariate distributions are available in the literature,20,21 most likely because the protocols developed to this purpose are rather complex. More recently SEC/NMR, for which an ample literature exists,22-24 has been used to gain information on size and composition for low MM copolymers.25 Even more attractive (since both NMR and MS instruments are nowdays widely available) is the present attempt to combine data from SEC/NMR and from SEC/

10.1021/ma9903097 CCC: $18.00 © 1999 American Chemical Society Published on Web 09/16/1999

7016

Montaudo and Montaudo

MALDI, leading to a direct measure of the bivariate distribution in copolymers. NMR is always able to determine the composition of a copolymer fraction, independent from its molar mass value, but it provides reliable molar mass estimates only up to 10 000-20 000 Da. On the other side, MALDI mass spectra enable to measure molar masses up to very high values (106 Da), but lose resolution above 30 000-50 000 Da, and therefore, the composition of high molar mass copolymers cannot be determined. Therefore, if NMR and mass spectrometry (MS) are separately coupled to SEC to analyze copolymer fractions, they reveal some intrinsic limitations. Instead, if they are used in parallel to determine the composition (NMR) and molar mass (MALDI) of the SEC fractions of a copolymer, the determination of the bivariate distribution becomes possible. Two random poly(methyl methacrylate)/polybutyl acrylate (PMMA/PBA) copolyesters obtained at high and low conversions, respectively, were investigated here. SEC/NMR data allowed the computation of the fractional composition, whereas SEC/MALDI data provided the molar mass estimates, respectively. From the knowledge of mass and composition of the copolymer fractions, combined with Stockmayer’s theoretical distribution to estimate the composition distribution of each fraction, bivariate distribution maps were derived. Experimental Section Materials. Copolymer samples S1 and S2 are PMMA/PBA copolymers. Sample S1 was polymeryzed in ethyl acetate using azobisdiethyl isobutyrate as an initiator. The monomers conversion amounts to about 4%, and the average molar fraction of MMA in the copolymer is 0.25, as measured by NMR. Sample S2 was polymerized in ethyl acetate using tertbutyl perpivalate as initiator. The monomer conversion amounts to about 100% and the average molar fraction of MMA in the copolymer is 0.41, as measured by NMR. SEC Fractionation. The analyses were performed on a Polymer Lab apparatus, equipped with four UltraStyragel Waters columns (in the order 1000, 500, 10000, and 100 Å pore size) attached in series, using a Polymer Lab differential refractometer. A 60 µL aliquot of polymeric solution (15 mg/ mL in THF) was injected. The flow rate was 1 mL/min, and 50-60 fractions of 0.24 mL were collected. NMR. NMR analyses were performed on a Varian Unity Inova 500 spectrometer at room temperature using CDCl3 as a solvent and tetramethylsilane as internal standard. The 1H NMR spectra were acquired with the following acquisition parameters: spectral width of 4722.3 Hz, 131 072 data points, 700 accumulations, and an acquisition time of 3.47 s. The copolymer composition of each fraction was determined by taking the ratio between the area in the region 4.16-3.92 ppm, corresponding to MMA units, and the area in the region 3.66-3.51 ppm, corresponding to butyl acrylate units. The results are reported in Table 1. The signal-to noise ratio (S/ N) for fraction 61 of sample S2 (the least abundant of the fractions analyzed) was about 170:1. MALDI Sample Preparation. A 0.02 mL aliquot of the chromatographic eluate in each fraction was added to 0.02 mL of a 0.7 M solution of 2-(4-hydroxyphenylazo)benzoic acid (HABA) matrix. Probe tips were loaded with 10-3 mL of the resulting solution, and the solvent was slowly evaporated off. MALDI-TOF Mass Spectra. A Bruker REFLEX mass spectrometer was used to obtain the matrix-assisted laser desorption/ionization time-of-flight mass spectra. The spectrometer is equipped with a nitrogen laser (337 nm., 5 ns), a flash ADC (time base of 4 ns), and a HIMAS detector. The laser irradiance was slightly above threshold (ca. 106 W/cm2). Ions below m/z 350 were removed with pulsed deflection, and

Macromolecules, Vol. 32, No. 21, 1999 Table 1. SEC/MALDI and SEC/NMR Data for Copolymers S1a and S2b sample fraction S1

S2

38 41 47 51 53 57 61 30 31 36 40 41 42 43 44 45 46 47 48 49 50 51 54 56 58 61 62 65

Vec, 28.36 29.02 30.34 31.22 31.66 32.54 33.42 27.75 28.25 29.11 30.01 30.25 30.52 30.75 31.01 31.25 31.52 31.75 32.01 32.25 32.51 32.75 33.51 34.01 34.51 35.25 35.51 36.25

CMMAd 0.25 0.25 0.25 0.39 0.35

0.42

0.42 0.65 0.78

Mne

Mwf

Dg

90000 92000 1.02 63000 64000 1.01 35000 36000 1.03 20000 21000 1.05 18000 19000 1.06 11000 11550 1.05 7000 7700 1.10 173000 175000 1.01 133000 135000 1.03 89000 90000 1.01 72000 73500 1.02 64000 67000 1.04 55000 57000 1.04 50000 51500 1.03 45000 47700 1.06 39000 41400 1.06 34000 35400 1.04 31000 32860 1.06 28000 29400 1.05 25000 26000 1.04 23000 23920 1.04 21000 21840 1.04 17000 17900 1.05 13500 13800 1.02 11000 11400 1.03 7200 7800 1.08 6700 7250 1.08 5000 5400 1.08

weighth 0.174 0.239 0.318 0.265 0.212 0.118 0.066 0.157 0.234 0.282 0.298 0.291 0.274 0.252 0.223 0.194 0.164 0.139 0.107 0.099 0.084 0.073 0.046 0.036 0.031 0.024 0.022 0.018

a For sample S1 the average molar fraction of MMA in the copolymer is 0.25, the average Mn is 22 000, and the average Mw is 38 000. b For sample S2 the average molar fraction of MMA in the copolymer is 0.41, the average Mn is 43 000, and the average Mw is 91 000. c SEC elution volume (mL). d Molar fraction of MMA in the copolymer fraction (as determined by NMR). e Mn of the SEC fraction as determined by MALDI. f Mw of the SEC fraction as determined by MALDI. g Mw/Mn ratio of the SEC fraction as determined by MALDI. h Weight fraction, as derived from the SEC trace.

Figure 1. SEC trace for sample S1 (lower trace) and for sample S2 (upper trace). The insets display the MALDI mass spectra of selected SEC fractions of sample S2. 100 transients were summed. The MALDI mass spectra of the SEC fractions were processed with the XMASS program from Bruker. The program uses mass spectral intensities to compute the quantities known as most-probable molar mass, numberaverage molar mass, weight-average molar mass, and polydispersity index (denoted as Mp, Mn, Mw, and D, respectively) of each selected fraction. Calculations. The SEC traces (see Figure 1) show the weight fraction of copolymer, W, as a function of Ve, the elution volume. W is simply the RI detector response, since it was assumed that the refractive index increments (dn/dc) for MMA and BA in chloroform are the same (it is known26 that in

Macromolecules, Vol. 32, No. 21, 1999

Bivariate Distribution in PMMA/PBA Copolymers 7017 Each mass value corresponds to a single average copolymer composition, as measured by NMR spectra. This average value would be satisfactory in the case of a narrow composition distribution in the SEC fraction. However, for heterogeneous copolymers, such as high conversion samples, copolymers having different compositions may be eluted at the same SEC volumes.1,2 To cope with this problem, we estimated the weight of macromolecular chains that possess a composition, CMMA, which may be different from the average value, Cav. More specifically, we computed the weight of macromolecular chains in which CMMA takes all the values between 0 and 1 by assuming that the composition spread, β, is given by Stockmayer’s theoretical distribution:12,13

β ) exp(-0.5(Cav - CMMA)2/(0.001σ2)) Figure 2. Mass calibrated SEC lines for sample S1 (circles) and for sample S2 (squares): the graph reports MALDI-TOF molar masses vs elution volume for each SEC fraction acetone the dn/dc value for MMA and for BA are 0.112 and 0.113 mL/g, respectively, and thus the difference in sensitivity is lower than 1%). SEC calibration lines in Figure 2 were used to convert eluted volumes in molar masses. Authentic GPC calibration plots for samples S1 and S2 were obtained by the correlation of log Mw, obtained by MALDI spectra, of each fraction with the corresponding eluted volume (Figure 2). The calibrated SEC traces were used to compute average molar mass and dispersion of the unfractionated copolymers using the Caliber software distributed by Polymer Lab. The type of calibration selected by us was “narrow standards”; the calibration function was “polynomial of order 1”, and the calculation method was “area based”, since the distributor claims that the cited calculation method yields more accurate results than the “height based” method. The results were as follows: sample S1, (Mw ) 38 000, Mn ) 22 000, D ) 1.7; sample S2, Mw ) 91 000, Mn ) 43 000, D ) 2.1. Data in columns 4, 5, and 8 of Table 1 and the SEC traces in Figure 1 were used to compute the bivariate distribution of chain composition and sizes for samples S1 and S2. These figures were grouped in triplets, reporting the weight fraction of macromolecular chains having mass M and an average copolymer composition (Cav).

(1)

where σ2 is the variance and it is given by Cav(1 - Cav)/s, where s is the number of repeating units in the chain. Using the above equation, we generated the compositional distribution for sample S1 and for sample S2, which were used to produce the 3D-mesh plots in Figures 4-6. In the case of the mass spectra of high conversion PMMA/ PBA copolymer samples taken from Nuwaysir et al.,27 the composition spread was measured directly from the spectra. The formula28-30 which relates the spread to experimental MS intensities is

σ2 ) 1000

∑ ∑ (C

s

- m2Iexp)2δs

(2)

where Iexp is the intensity of mass spectral peak corresponding to the oligomer AmBn, Cs is the average molar fraction of MMA in chains which possess s of repeating units, δs is equal to 1/s when m + n ) s and is zero otherwise and where the summations are extended to all nonnegative values of n and m.

Results and Discussion SEC fractionation was used to obtain a series of fractions from two high molar mass, random, polymethyl methacrylate/polybutyl acrylate (PMMA/PBA) copolymers produced by radical initiation.

Figure 3. 500 MHz 1H NMR spectrum of fraction 41 of sample S1.

7018

Montaudo and Montaudo

Macromolecules, Vol. 32, No. 21, 1999

Figure 4. (a) Bivariate distribution of chain sizes and compositions for sample S1. (b) Contour map of the bivariate distribution of chain sizes and compositions for sample S1.

One copolymer sample (S1) is a low conversion (4%) and the other (S2) is a high conversion (100%) copolymer. Figures 1a and 1b show the SEC traces for samples S1 and S2, respectively. The trace corresponding to S2 displays a broader peak than the trace corresponding to S1. Samples S1 and S2 were separately injected into the SEC apparatus, and about 50 fractions were collected

from each eluate. Several SEC fractions were then subjected to off-line MALDI and NMR analysis, respectively (Table 1). The SEC fractions analyzed by MALDI-TOF yielded excellent spectra with narrow distributions up to high molar masses (170 000 Da, Figure 2), and the mass spectra of these nearly monodisperse samples allowed the computation of reliable values of the molar masses corresponding to the fractions.8-10

Macromolecules, Vol. 32, No. 21, 1999

Bivariate Distribution in PMMA/PBA Copolymers 7019

Figure 5. (a) Bivariate distribution of chain sizes and compositions for sample S2. (b) Contour map of the bivariate distribution of chain sizes and compositions for sample S2.

In Figure 1 (insets) are shown some MALDI spectra corresponding to selected fractions of copolymer sample S2, taken at different elution times. The log MM values of the fractions showed a linear correlation with the elution volume of each fraction and allowed the calibration of the SEC traces for samples S1 and S2 against MM (Figure 2), and the calibrated SEC trace could then be used to compute average molar mass and dispersion of the unfractionated copolymer

sample S1 (Mw ) 38 000, Mn ) 22 000, D ) 1.7) and S2 (Mw ) 91 000 Mn ) 43 000, D ) 2.1). Table 1 reports also the composition of the S1 and S2 fractions analyzed by 500 MHz 1H NMR. The copolymer composition of each fraction was determined by taking the ratio between the area in the region 4.16-3.92 ppm, corresponding to MMA units, and the area in the region 3.66-3.51 ppm, corresponding to butyl acrylate units. (Figure 3).

7020

Montaudo and Montaudo

Macromolecules, Vol. 32, No. 21, 1999

Figure 6. (a) Bivariate distribution of chain sizes and compositions for sample S3. (b) Contour map of the bivariate distribution of chain sizes and compositions for sample S3.

From data in Table 1, it can be seen that the for the low conversion copolymer S1 the composition is constant throughout the sample (PMMA/PBA 24/76). Instead, for sample S2 the composition varies, and the fractions taken in the SEC region close to the peak elution volumes possess compositional values close to the average ones (PMMA/PBA 41/59). At higher masses the composition takes values up to 65% BA. At low masses,

instead, the macromolecular chains are rich in MMA (about 78%, Table 1). The NMR spectra yield exclusively the average copolymer composition of a fraction, but do not give information on its composition spread. We assumed here that the spread takes its theoretical value (see Experimental Section).

Macromolecules, Vol. 32, No. 21, 1999

Using the above assumption, we computed the bivariate distribution of chain sizes and compositions. Figure 4a shows the bivariate distribution for the low conversion sample S1, displaying the weight fraction of macromolecules as a function of size and MMA/BA ratio. In Figure 4b is shown a contour map, showing further details of the bivariate distribution corresponding to sample S1. The distribution is symmetric with respect to the molar fraction of comonomers and nicely shows the theoretically predicted12,13 broadening of composition at low masses for low conversion copolymers. In Figure 5a is shown the bivariate distribution for the high conversion sample S2, displaying the weight fraction of macromolecules as a function of size and MMA/BA ratio. It appears clearly that this high conversion sample, having an average MMA/BA composition of 41/59, has instead a sensible composition heterogeneity, as can be noted also from the inspection of the contour map reported in Figure 5b. It could be argued that for low conversion polymers, such as sample S1, eq 1 (Stockmayer’s theoretical distribution12,13), may be acceptable, but in general the present method cannot be applied to high conversion copolymers, since conversion affects the composition distribution. Actually, we have performed some controls in order to test the validity of the method in the case of high conversion copolymers, and we estimate that eventual distortions introduced by our modeling into the 3D mesh plots of high conversion copolymers are minor. Let us recall that bivariate distributions12 can be obtained directly from mass spectra of copolymers, provided that these copolymers have low molar masses. In fact, at low masses the mass spectra show mass resolved peaks, and therefore both mass and composition distribution can be extracted from such mass spectral data.28-30 The composition distribution is directly measured in this experiment, and is not merely an average value, so that no assumptions need to be made to estimate the sample composition distribution. The experimental variance of the Gaussian distribution corresponding to each discrete chain size can be then obtained and compared with that calculated by Stockmayer’s theoretical distribution used in our modeling. In a paper particularly relevant to the present one, Nuwaysir et al.27 reported the analysis of three high conversion PMMA/PBA copolymer samples, by laser desorption fourier transform mass spectrometry (LD/ FTMS). We considered the LD/FTMS mass spectrum of the PMMA/PBA sample, which possesses an average composition27 of 78.5/21.5, which we refer to as sample S3, a sample which possesses an average composition27 of 83/17, which we refer to as sample S4, and a sample which possesses an average composition27 of 88/12, which we refer to as sample S5. The experimental mass spectral intensities for samples S3, S4, and S5 were inserted in eq 2 to yield the experimental variances. The variances (Table 2, columns 2, 4, and 6) decrease strongly with increasing size going from values of 23 to 2 for sample S3 and from 28 to 1 for sample S5. Table 2, columns 3, 5, and 7, also reports the theoretical variances for samples S3, S4, and S5 computed applying Stockmayer’s theoretical distribution (eq 1).

Bivariate Distribution in PMMA/PBA Copolymers 7021 Table 2. Comparison between Experimental and Calculated Variance of the Gaussian Compositional Distribution for PMMA/PBA Copolymer Samples S3, S4, and S5 sample S3

sample S4

sample S5

oligomer size measda calcdb measdc calcdd measde calcdf 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27

23 23 25 29 30 21 26 25 19 21 21 21 27 27 22 27 22 20 10 13 5 2

33 28 25 22 20 18 16 15 14 13 12 11 11 10 10 9 9 9 8 8 8 7

18 16 14 12 11 9 12 11 10 10 10 10 10 9 7 6 4

26 22 19 17 15 14 13 12 11 10 10 9 9 8 8 7 7

28 15 24 25 13 16 15 10 6 7 5 12 8 8 2 5 3 2 1

21 17 15 13 12 11 10 9 8 7 7 6 6 6 5 5 5 5 4

a Variance measured using eq 2 from the mass spectrum for sample S3.27 b Variance calculated using eq 1 for sample S3. c Variance measured using eq 2 from the mass spectrum for sample S4.27 d Variance calculated using eq 1 for sample S4. e Variance measured using eq 2 from the mass spectrum for sample S5.27 f Variance calculated using eq 1 for sample S5.

The experimental variance values and those calculated applying Stockmayer’s distribution are of the same order of magnitude as the theoretical ones (Table 2), and the ageement is fair enough to encourage using eq 1 for high conversion samples, as we have done in the present method. In Figure 6a is reported the bivariate distribution for sample S3, and in Figure 6b is shown the corresponding contour map. Although the molar masses in Figure 6 reach only values of about 4000 Da (as compared to 300 000 Da in Figures 4 and 5), the compositional heterogeneity is detectable also for this sample. Conclusions Although several methods have been proposed to determine bivariate distributions, relatively little data20,21 are available on this important aspect of copolymer characterization, perhaps because of the complexity of the methods available to the present. We propose here a generally applicable method to determine bivariate distribution of masses and composition in copolymers. SEC fractionation of two random copolyesters polymethyl methacrylate/ polybutyl acrylate (PMMA/PBA) obtained at high and low conversion, respectively, was used to collect nearly monodisperse fractions that allowed the computation of the corresponding molar masses (by MALDI measurements) and of compositions (by NMR measurements) for the two copolymers. Bivariate distribution maps were derived by combining SEC/NMR and SEC/MALDI data. Acknowledgment. Partial financial support from the Italian Ministry for University and for Scientific and Technological Research (MURST), from Progetto Final-

7022

Montaudo and Montaudo

izzato MATERIALI Speciali per Tecnologie Avanzate II (CNR, Rome), and from the National Council of Research (CNR, Rome) is gratefully acknowledged. References and Notes (1) Netopilik, M.; Bohdanecky, M.; Kratochvil, P. Macromolecules 1996, 29, 6023. (2) Radke, W.; Simon, P. F. W.; Muller, A. H. E. Macromolecules 1996, 29, 4926. (3) Stockmayer, W. H.; Moore, L. D.; Fixman, M.; Epstein, B. N. J. Polym. Sci. 1955, 16, 517. (4) Kotaka, T.; Tanaka, T.; Ohnuma, H.; Murakami, Y.; Inagaki, H. Polym. J. 1970, 1, 245. (5) Zammit, M. D.; Davis, T. P. Polymer 1997, 38, 4455. (6) Runyon, J. R.; Barnes, D. E.; Rudd, J. F.; Tung, L. H. J. Appl. Polym. Sci. 1969, 13, 2359. (7) Trathnigg, B.; Yan, X. Chromatographia 1992, 33, 467. (8) Montaudo, G.; Garozzo, D.; Montaudo, M. S.; Puglisi, C.; Samperi, F. Macromolecules 1995, 28, 7983. (9) Montaudo, G.; Montaudo, M. S.; Puglisi, C.; Samperi, F. Rapid Commun. Mass Spectrom. 1995, 9, 1158. (10) Montaudo, G.; Montaudo, M. S.; Puglisi, C.; Samperi, F. Int. J. Polym. Anal., Charact. 1997, 3, 177. (11) Montaudo, M. S.; Puglisi, C.; Samperi, F.; Montaudo, G. Macromolecules 1998, 31, 3839. (12) Stockmayer, W. H. J. Chem. Phys. 1945, 13, 199. (13) Allen, G., Beington, J., Eds. Comprehensive Polymer Science; Pergamon: Oxford, England, 1989; Vol. 3, Chapter 2. (14) Dumelow, T.; Holding, S. R.; Maisey, L. J.; Dawkins, J. V. Polymer 1986, 27, 1170. (15) Schunk, T. C. J. Chromatogr. A 1994, 661, 215.

Macromolecules, Vol. 32, No. 21, 1999 (16) Pasch, H.; Trathnigg, B. HPLC of Polymers; Springer: Berlin, 1998. (17) Willis, J. N.; Wheeler, L. In Chromatographic Characterization of Polymers; American Chemical Society: Washington, DC, 1995; Chapter 19. (18) Glockner, G. Polymer Characterization by Liquid Chromatography; Elsevier: Amsterdam, 1987. (19) Allen, G., Beington. J., Eds. Comprehensive Polymer Science; Pergamon: Oxford, England, 1989; Vol. 1, Chapter 16. (20) Mori, S. Anal. Chem. 1988, 60, 1125. (21) Servaty, S.; Kohler, W.; Meyer, W. H.; Rosenhauer, C.; Spickermann, J.; Rader, H. J.; Wegner, G.; Weier, A. Macromolecules 1998, 31, 2468. (22) Albert, K. J. Chromatogr. A 703, 123, 1995. (23) Korhammer, S.; Bernreuther, A. Fresenius J. Anal. Chem. 1996, 354, 131. (24) Ute, K.; Niimi, R.; Hongo, H.; Hatada, K. Polym. J. 1998, 30, 439. (25) Hatada, K.; Ute, K.; Kitayama, T.; Yamamoto, M.; Nisimura, T.; Kashiyama, M. Polym. Bull. 1989, 21, 489. (26) Brandrup, J.; Immergut, E. H. “Polymer Handbook” Wiley: NY, 1989. (27) Nuwasir, L. M.; Wilkins, C. L.; Simonsick, W. J. J. Am. Soc. Mass Spectrom. 1990, 1, 66. (28) Montaudo, M. S.; Montaudo, G. Macromolecules 1992, 25, 4264. (29) Montaudo, M. S.; Puglisi, C.; Samperi, F.; Montaudo, G. Macromolecules 1998, 31, 8666. (30) Montaudo, M. S.; Puglisi, C.; Samperi, F.; Montaudo, G. Rapid Commun. Mass Spectrom. 1998, 12, 519.

MA9903097