Sustainable water reclamation from different feed streams by Forward Osmosis Process Using Deep Eutectic Solvents as Reusable Draw Solution Ashesh Mahto, Dibyendu Mondal, Veerababu Polisetti, Jitkumar Bhatt, Nidhi M. R., Kamalesh Prasad, and Nataraj Sanna Kotrappanavar Ind. Eng. Chem. Res., Just Accepted Manuscript • DOI: 10.1021/acs.iecr.7b03046 • Publication Date (Web): 17 Nov 2017 Downloaded from http://pubs.acs.org on November 18, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Industrial & Engineering Chemistry Research is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

1

Sustainable water reclamation from different feed streams by Forward

2

Osmosis Process Using Deep Eutectic Solvents as Reusable Draw

3

Solution

4 5

Ashesh Mahto,a,d Dibyendu Mondal,a Veerababu Polisetti,c Jitkumar Bhatt,b,d Nidhi M. R., Kamalesh Prasadb,d* and S.K. Nataraja*

6 7 8

a

Sustainable Energy Materials and Processes group, Centre for Nano and Material Science, Jain University, JGI Global Campus, Kanakapura Road, Ramanagaram, Bangalore 562 112, India

9 10

b

11 12

c

Reverse Osmosis Membrane Division, CSIR-Central Salt and Marine Chemicals Research Institute (CSIR-CSMCRI), G. B. Marg, Bhavnagar 364 002, India.

13 14

d

Academy of Scientific and Innovative Research (AcSIR), Central Salt and Marine Chemicals Research Institute, G.B. Marg, Bhavnagar 364 002, India.

15 16 17 18

*Correspondence:

Natural Products and Green Chemistry Division, CSIR-Central Salt and Marine Chemicals Research Institute (CSIR-CSMCRI), G. B. Marg, Bhavnagar 364 002, India

Dr. S. K. Nataraj ([email protected]; [email protected]) and Dr. Kamalesh Prasad ([email protected]/[email protected]) Tel: +91-278-2567563

19 20

ABSTRACT: Sustainable and low-cost reusable water recovery process from industrial

21

wastewater may have potential positive impact towards potable water crisis in several

22

industrial processes. Quite a number of approaches such as chemical processes, biological

23

treatment and high-pressure membrane based processes have been developed to address this

24

crucial issue but most of them are suffered from several discrepancies. Due to the suitability

25

of deep eutectic solvents (DESs) as promising draw solution (DS) for forward osmosis (FO)

26

processes, herein the potential of DESs for the recovery of reusable water from seawater, dye

27

contaminated wastewater and tannery wastewater by continuous FO process is demonstrated.

28

Under optimized process conditions, > 90% reusable water was recovered from different feed

29

solutions with an average water flux of 5 L.m-1.h-1. Due to the high freezing point (Tf)

1 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

30

difference between water & DES, phase separation of the DES and water mixture obtained at

31

the end of the process was achieved at a temperature ca. -5 °C and DSs thus recovered were

32

reused in subsequent batch experiments (three cycles), where minimal loss of water flux was

33

observed. The recovered water was found to have low contamination making it suitable for

34

different purposes.

35

Key Words: Forward Osmosis; Tannery Wastewater, Draw Solution, Recovery; Deep

36

Eutectic Solvent; Recycle

37

INTRODUCTION

38

Resource recovery from waste is a challenging task which has often been in focus for greater

39

importance ahead of simply being one of the principles of ‘reduce, reuses or recycle’. Today,

40

the world is facing serious problem due to declining sources for fresh water and the

41

commitment to reclaim potable and/or reusable water from wastewater is the call of the day.

42

As of today, reverse osmosis (RO) holds the largest share of market for sea water desalination

43

[1] with well-defined and projected economical parameters, challenges and future prospects

44

for the process [2,3]. On the other hand, nanofiltration (NF) and ultrafiltration (UF) processes

45

have found widespread applications in waste water treatment, standalone [4,5] or sometimes

46

in combination with other processes like membrane bioreactor (MBR) [6,7] and membrane

47

distillation (MD)[8]. Microfiltration (MF) and UF processes are also employed as a

48

pretreatment step for other membrane-based processes like RO and MBR [7,9,10].

49

The market for forward osmosis is growing rapidly owing to the extraordinary

50

progress being made in the fields of membrane development [11-14], draw solution[15-18]

51

and process design[19, 20]. Albeit a high number of publications and patents being filed in

52

the niche of FO, there are only a limited number of reports which deals with the overall

53

process, i.e., recovery and the quality of final potable/reusable water [18, 19, 21]. With robust 2 ACS Paragon Plus Environment

Page 2 of 33

Page 3 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

54

FO membranes developed by HTI, Albany, US being utilized in most of the FO research

55

works and pilot plants [19, 20, 22]. Furher with the pioneering work by Modern Waters &

56

Oasys Water Inc. in developing the process and technology at commercial scale [19], FO is

57

now competing with other technologies in both sea water desalination and waste water

58

treatment [23].

59

Even though there are inherent advantages associated with FO, such as requirements of no

60

or low-pressure for operation, low fouling propensity of membranes which in turn reduces

61

the cleaning & replacement cost, high water flux and recovery rate[24, 25], it still face some

62

challenges due to the need for a regeneration step to recover the draw solution (DS) or draw

63

agent at the end of the operation [26]. There are many instances where FO process is

64

integrated with another membrane based process viz. RO[27, 28], NF[16, 29] and MD[30,

65

31]or other external stimuli like magnetic field [32, 33] or heat [19, 34] to recover the DS and

66

product water. Recent research endeavours being carried out in this area suggest that the

67

specific energy consumption for hybrid FO-NF cannot be lower than that of RO desalination

68

[35] even with a membrane having infinite permeability and 100% rejection. Another report

69

invariably points out the regeneration of DS as the most energetically unfavorable step

70

compared to direct desalination [36] and for FO to be able to compete, the regeneration

71

process must be significantly more efficient than RO.

72

Following several estimations and assessments[25] it is projected that for FO to be

73

economically viable, it should be employed for applications where RO fails, for example

74

high-quality water recovery from highly contaminated wastewater. The FO process is viable

75

where potential fouling risk for RO membranes are very high and pretreatment cost adds up,

76

such as oil & gas, coal tailing wastewaters etc.[37, 38]. The FO process can be economically

77

advantageous in applications where DS recovery is not essential such as intermediate process

78

of dewatering [24, 39]. 3 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

79

DESs are new class of solvents which have similar physicochemical properties to that

80

of ionic liquids (ILs) but are more advantageous over the later due to their cost-effective

81

preparation, complete atom efficiency during syntheses etc., and their sourcing from various

82

bio-based resources make them bio-degradable as well as bio-compatible in number of

83

instances [40], [41]. DES is generally prepared by the combination of a hydrogen bond

84

acceptor (generally quaternary ammonium salts) and a hydrogen bond donor species, which

85

may include glycols like ethylene glycol (EG) and glycerol (Gly), organic acids, amino acids

86

and sugars [42]. In one of the reports, crude glycerol was used as a DS for FO application

87

[43]. Apart from this there are no other reports available on the application of DES as DS for

88

FO applications except our previous attempt to show the potential of DES as DS for delicate

89

applications like concentration of DNA and protein by FO process [17]. However, there

90

certain DESs are being used in separation and purification for different biomolecules by

91

chromatographic technique and other solid-liquid extraction methods [44].

92

The present work focuses on the utilization of potentials of DESs as DS for the

93

recovery of fresh water from brackish water, seawater, dye contaminated wastewater and

94

tannery wastewater while regenerating and reusing DS for successive runs. Unlike previous

95

study [17], here emphasis has also been given on quality water recovery from highly

96

contaminated feed streams.

97

EXPERIMENTAL SECTION

98

Materials: Choline chloride, Glycerol & Ethylene Glycol were purchased from SD Fine

99

Chemicals, Mumbai. Polysulfone (MW=77,000-80,000) was purchased from Solvay. TMC,

100

MPD and Reactive Black-5 dye were procured from Sigma Aldrich, USA. Sea water was

101

collected from seashore (Ghogha beach 21.68˚N 72.27˚E), Gujarat, brackish water from a

102

local bore well in Bhavnagar, Gujarat, India. Tannery effluent and its concentrated solutes

4 ACS Paragon Plus Environment

Page 4 of 33

Page 5 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

103

were obtained as gift from CSIR-CLRI, Chennai, India. Further, concentrated solutes like

104

polyphenol, phenol-HCHO, Red brown dye and NaCl (SD Fine Chemicals) were used to

105

prepare simulated tannery wastewater. RO water was used for all control experiments and

106

washing purpose.

107

Preparation of Deep eutectic solvent (DES): The DESs were prepared following the

108

method as described in the earlier report [17]. In a typical reaction, both the hydrogen bond

109

acceptor (HBA) i.e., choline chloride (CC) and hydrogen bond donor (HBD) i.e., ethylene

110

glycol (EG) or glycerol (Gly) were mixed in 1:2 molar ratio followed by heating at 80 °C

111

with continuous stirring for 2 h until a clear homogenous liquid was formed(CC–EG 1:2 &

112

CC-Gly 1:2 respectively) (Figure 1).

113 114

Figure 1: Structure of two deep eutectic solvents used as draw solution in the present study.

115

Membrane fabrication: Indigenous thin-film composite polyamide (TFC-PA) membrane

116

comprised of an ultrafiltration (UF) support (polysulfone 15% w/w in DMF) layer on

117

polyester fabric (~30+100µm), with the thin polyamide selective layer (~200 nm) prepared on

118

UF-support by interfacial polymerization between trimesoyl chloride (TMC, 0.125 w/v% in

119

hexane) and m-phenylenediamine (MPD, 5 w/v% in water) monomers. The resultant

120

membrane was used as the semi-permeable barrier in all FO experiments. Post-treatments of 5 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

121

the TFC membranes were carried out by treating with citric acid (2%) and deionized water,

122

followed by glycerol coating (20%) [45,46]. Before using membranes in FO process,

123

membrane was washed with deionized water to regenerate the original surface and the

124

membrane was immersed in isopropyl alcohol (IPA) for 60-120 seconds and repeatedly

125

washed with deionized water.

126

Experimental Setup: FO experiments were carried out in lab-scale FO cells with an

127

effective membrane area of 0.0057 m2 and 0.006325 m2. Both FS and DS were circulated at a

128

flow rate of 1.8 L/min. In all experiments, the active layer of the membrane was facing the

129

FS. All the experiments were carried out for at least 6 hours after 1 hour of stabilization to

130

achieve steady state at 28±2°C. The reverse draw flux was estimated by conductivity meter

131

and total organic carbon (TOC) analyzer using Ultra-Pure water as FS. For every experiment

132

using recovered DS, fresh TFC-PA membrane was used.

133

Feed and Draw Solutions (FS & DS): For pure water flux, deionized water was used as a

134

feed and initial membrane characterization for flux and salt rejection were done using 2000

135

ppm NaCl and 2000 ppm MgSO4 as model FS. Tannery waste effluent (TDS- 60,600 ppm),

136

sea & brackish water, RB-5 dye in deionized water with different concentrations were used as

137

FS. Detailed characterization of feed streams is provided in subsequent sections. All the

138

experiments were carried with an initial FS:DS ratio of 10:1.

139

Methods:

140

Density was measured using Density & Sound Velocity Meter model DSA 500 M (Anton

141

Paar). The osmotic pressure was measured using Vapro® vapor pressure Osmometer (Model

142

5600 ELI Tech France). The viscosity was recorded on a Brookfield DV-II + Pro Viscometer

143

at 25 °C employing spindle No 18 at 10 rpm. All the experiments were performed at different

144

volume fraction of DES so as to replicate the dilution process during FO application. The 6 ACS Paragon Plus Environment

Page 6 of 33

Page 7 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

145

morphology of the membrane surface was recorded using scanning electron microscopy

146

(SEM, LEO 1430VP), UV-Visible Spectroscopy was used for estimating the concentration of

147

color and organic contaminants (Varian CARY 500), ATR-FT-IR (Perkin Elmer Spectrum

148

GX, FT-IR system, USA) spectra was employed for membrane surface characterization. The

149

elemental quantification was carried out for both FS and DS using inductively coupled

150

plasma- optical emission spectroscopy ICP-OES (ICP, Perkin Elmer, Optima 2000). Total

151

dissolved salts (TDS) and conductivity analysis were done using CON700, EUTECH

152

instrument. Further, the morphology of the membrane surface was studied using atomic force

153

microscope (AFM), Ntegra Aura, Model: nt-mdt (Russia). Total organic carbon (TOC) of

154

feed solution was measured using Elementar, Liqui TOC.

155

Membrane characterization:

156

Flux & rejection: As prepared TFC-PA membranes were tested for their performance in both

157

RO and FO modes. Average flux (Jv), solute back diffusion flux (Jb) and percentage rejection

158

were calculated by the following equations (1-3), respectively;

159

   = 

  

..………………………………..(1)





160

Jb = ∆TOC X

161

%  =

162

Where,  = Volumetric flux, Vt0 and Vtn are the volume levels of feed solution at time t0 and

163

tn respectively. Jb= Solute back diffusion rate, ∆TOC is the change in total organic carbon on

164

feed side in time “t”, A is the active membrane surface area and c is the concentration of

165

draw solution. Percentage rejection (% R) as the ratio of difference in concentration of feed

166

(Cf) and permeate (Cp) to the initial feed concentration.

..

………………………………..

∁ ∁! x100 ∁"

(2)

……………………………… (3)

7 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

167

RESULTS AND DISCUSSION

168

Properties of DES as draw solution (DS)

169

In the present study CC was used as HBA for the preparation of the DESs with EG and Gly.

170

This HBA is inexpensive as well as nontoxic and is produced in the megaton scale [47]. On

171

the other hand, Gly and EG are industrially important chemicals [48-51]. When HBD (Gly or

172

EG) is mixed in 2:1 molar ratio with CC (HBA), it effectively results formation of a solvent

173

with very low water activity (aw) [42]. The properties of DES with addition of water were

174

studied by monitoring changes in the thermodynamic (density variation, Figure 2a),

175

colligative property (osmotic pressure, Figure 2b) and physicochemical properties (viscosity,

176

Figure 2c) of CC-EG and water system at different ratios. Viability of a DS depends on many

177

factors, out of which effective regeneration process of DS is of utmost importance as it

178

directly influences the energy input. Evaluation of low concentration and low temperature

179

(~5-10°C) phase separation studies will give significant information in designing an

180

integrated FO system for simultaneous DS and water recovery. Understanding the variation

181

in density data at different dilution with water will provide valuable insight into the behavior

182

of DES components in aqueous mixtures and their effective recovery at low temperature.

183

Figure 2a shows the variation in the density of CC-EG-water binary mixture. The density

184

increased with the weight ratio of DES in the binary mixture owing to the higher density of

185

DES as compared to water. The density also increases with the hydrogen bond acidity

186

resulting in higher values for CC-Gly system as compared to CC-EG (Figure S1) [52].

187

Osmolality is the most important property of a draw solution for osmotic gradient driven FO

188

process. It is expected that dilution of DS for some extent may result in the dissipation of

189

osmotic energy, which can be minimized by monitoring the required dilution level without

190

comprising the osmotic gradient to maintain similar water flux. Therefore, it is important to

191

know the effect of osmolality of DES at different dilution levels with H2O. Osmolality 8 ACS Paragon Plus Environment

Page 8 of 33

Page 9 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

192

variation (Figure 2b) follows the same trend of a decay function as observed for density

193

(Figure 2a). The highlighted portion corresponds to the variation in the ratio of DES: water

194

from 1:2.6 to 1:5 (v/v). A steep drop in osmolality can be observed between 1:3.4 and 1:3.8

195

(CC-EG:Water) which looks more like an exponential decay function. Chilling (-5˚C) a DES-

196

water mixture at this composition did not result into segregation of ice (water) and DES

197

(liquid) layers while on the other hand, 1:8, 1:9 and 1:10 ratio mixtures showed visible

198

separation of ice and liquid DES. Although it might be a good option to stop the FO

199

experiment at 1:4 dilutions in terms of osmotic pressure drop, a ̴10 dilution showed best

200

results in terms of separation of DES from water. On the other hand, a highly viscous solution

201

is a nightmare to run FO process through the recirculation mode wherein cost will add-up to

202

run the pumps. Therefore, it is also important to know the change in viscosity of DES-water

203

mixture when employed as DS. This is one of the bottlenecks to use CC-Gly (viscosity 222

204

cP) as a DS in FO application [17]. CC-EG on the other hand is less viscous compared to CC-

205

Gly and interestingly, a 1:1 CC-EG:water mixture showed viscosity of almost the same

206

magnitude as that of water (Figure 2c). This resulted in ease of circulation and will also have

207

a profound effect on the pump life.

9 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

208 209

Figure 2: (a) Density (ρ) (inset- speed of sound in DES-Water mixture), (b) Osmolality

210

(inset: zoomed-in region of exponential decay like trend in osmolality with increase in water

211

concentration), and (c) Viscosity as a function of volumetric ratio of CC-EG and water at

212

different ratio.

213

Properties of the membrane used for FO process

214

Firstly, TFC membrane used in this study has an asymmetric structure consisting of polyester

215

fabric, ultrafiltration (UF) microporous support layer and polyamide selective layer as

216

depicted in the schematic (Figure 3(a)).The membrane was prepared following previous

217

procedure [45]. Figure 3(b) shows SEM image of the dense polyamide selective layer. The

218

ATR FT-IR spectrum in Figure 3(c) corresponds to polyamide layer formation as on the

219

asymmetric support. The characteristic Amide-I stretching can be seen at ~1650 cm-1 (C=O)

220

which partially overlaps with the N-H bending vibration (amide-II) and can be seen around

221

1545 cm-1 with the peak at 1250 cm-1 corresponding to N–C stretch. All membranes were

10 ACS Paragon Plus Environment

Page 10 of 33

Page 11 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

222

conditioned and characterized for salt rejection experiments under applied pressure prior to

223

use in FO.

224

225 226

Figure 3: (a) Schematics depicting across-sectional view of asymmetric TFC-PA membrane,

227

(b) Surface FE-SEM image of selective polyamide layer (top view). (c) ATR FT-IR spectra

228

correspond to thin-film composite polyamide on polysulfone UF support, (d-f) AFM surface

229

morphology and 3D images of pristine polyamide layer, height profile corresponding to the

230

green horizontal line in (d), and (g&h) AFM image of IPA treated polyamide membrane with

231

(i) height profile corresponding green line in (g).

232

Before testing, each membrane was treated with isopropyl alcohol (IPA) to condition the

233

selective layer. Figure 3(d & h) shows the AFM images of surface topography of pristine

234

TFC membrane in 2D and 3D format. The average roughness value noted to be 16.708 nm.

235

Polyamide thin film (~160 nm) selective layer results in a “splash” like finish during

236

interfacial polymerization. On the other hand, IPA treated TFC shows an average roughness

11 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

237

of 37.744 nm. Interfacial polymerization in case of TFC membrane preparation is optimized

238

to be quick and imperfect so as to retain minimum thickness. Thus, the higher roughness of

239

TFC membrane obtained after IPA treatment may be due to the removal of unreacted

240

monomers of amine leftover during interfacial polymerization. Increase in roughness may

241

also be due to removal of low molecular weight polymer chains from the selective layer

242

during IPA washing. It can be concluded that IPA contact with polyamide layer results in

243

membrane swelling and washing off the IPA removes unreacted monomers, debris and by-

244

products resulting in a more open membrane surface [53, 54]. The physical swelling of

245

aromatic polyamide chains in the presence of IPA can be attributed to similar Hildebrand

246

solubility parameters (δ) which is 23.6 MPa1/2 for IPA and 23 MPa1/2 for the polyamide

247

active layer[55]. Higher roughness in the IPA treated TFC membrane may cause fouling

248

problem, however the fouling propensity increases with roughness (although not linearly)

249

mostly in RO processes, wherein the composition of feed and applied pressure plays a major

250

role in fouling. Whereas in FO, as there is no applied pressure the extent of fouling will be

251

less.

252

Further, membranes were characterized by measuring the flux and standard salt (NaCl and

253

MgSO4) rejection at different applied pressure. At 4 bar and 26 bar NaCl rejection was >94%

254

whereas MgSO4 rejection was >99%. In both the cases, specific flux varied between 1.3 L.m-

255

2

256

characterized with pure water feed followed by 2000 ppm NaCl and MgSO4 simulated

257

solutions as FS and the two DESs as DS. In all cases, a feed tank carrying 1L FS and draw

258

tank having 100 mL of DES (CC-EG or CC-Gly) were connected to circulating pumps. The

259

volume of FS in the feed tank was observed to be decreasing gradually and permeate flux was

260

volumetrically measured every hour for each feed solution. Once the experimental conditions

261

were optimized, ~2000 ppm NaCl and ~2000 MgSO4 solutions were subjected to dewatering

.h-1.bar-1 and 1.8 L.m-2.h-1.bar-1. The membrane flux performance in FO mode was first

12 ACS Paragon Plus Environment

Page 12 of 33

Page 13 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

262

process through TFC membrane. For a 10-hour FO run with pure water as FS and CC-EG as

263

DS, an average flux of 3.6 L.m-2.h-1 (Figure S2). The FO performance of home-made TFC

264

membrane using 3M NaCl as DS and DI water as feed solution has also been carried out. The

265

results shows an average flux of 2.8 L.m-2.h-1, which is 28.5 % lower than the flux obtained

266

with CC-EG (1:2 mol ratio) as DS.. To know the solute transport from DS to FS during FO

267

process, an experiement was conducted using tap water as feed solution (Initial TOC = 31.89

268

mg.L-1) and CC-EG as DS. After 10h of continous FO run the TOC value of the FS was

269

58.93 mg.L-1 which results a reverse solute flux of 0.098 g.m-2.h-1.

270

Recovery of reusable water from Seawater and brackish water using DES as Draw solution

271

Initially, desalination experiments were conducted to evaluate the DESs (for their osmotic

272

dewatering efficiency from feed solutions of MgSO4 and NaCl (~2000 ppm). With time, the

273

volume of FS in the feed tank was observed to be decreasing gradually. All experiments were

274

concluded after every 10 hours FO run to quantify FS and DS for their concentrations.

275

Pristine DES solution CC-EG produced 5.2 L.m-2.h-1 fluxes for NaCl feed with ~42 % water

276

recovery. On the other hand, CC-Gly osmotically dewatered at a rate of 7.54 L.m-2.h-1 and 4.5

277

L.m-2.h-1 for NaCl and MgSO4 feeds with 33.33 % and 20.5 % water recovery, respectively

278

(Figure 4(a-d)). For both DESs, NaCl concentration varied from 20-40% whereas for MgSO4

279

feed, 30-60% concentration was achieved during the FO run. Interestingly, in seawater

280

desalination, CC-Gly showed marginally higher initial fluxes compared to CC-EG. However,

281

compared to pure water and simulated salt feed solutions, seawater and brackish water

282

desalination flux was marginally higher, which according to the osmolality difference

283

between the FS and DS seems improbable. Experiments were repeated thrice to corroborate

284

the findings. One possible reason may be the presence of high concentration of electrolytes in

285

the seawater which results in preferential adsorption and transport of water molecules through

286

the polymeric membrane, nevertheless more detailed analysis need to be carried out to claim

13 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

287

such possibility. Brackish water was desalinated at a higher rate compared to seawater

288

(Figure 4c & d), CC-EG produced higher fluxes for brackish water while for seawater, CC-

289

Gly exhibited higher flux. After about 5 hours of FO run, the flux data obtained by CC-EG

290

and CC-Gly for brackish water desalination coincided at about 7 LMH but in case of

291

seawater desalination, CC-Gly continued to produce higher fluxes than CC-EG. Although

292

higher flux was obtained using CC-Gly as DS as compared to CC-EG, the later was

293

considered as an optimum DS than former due to the higher viscosity of CC-Gly (222 cP, at

294

25 ˚C) for which continuous circulation will require more energy input when compared to

295

CC-EG (viscosity, 33 cP 25 ˚C). Another reason for employing CC-EG as DS for all the

296

experiments below is the ease of separation by chilling (discussed below).

297

Further, exploiting the colligative property of diluted draw solution, theoretical freezing point

298

depression of water upon dilution was calculated. Calculated Tf

299

mixing (Figure S3) shows that phase separation of water can be achieved from diluted DES at

300

-5 to -10 °C, assuming homogenous interactions between water and DES moiety throughout

301

the sample. A typical photograph of diluted CC-EG after freezing step for the recovery of

302

product water and draw solution is shown in Figure 4(e). There is a clear separation of

303

concentrated draw solution and icy product water, however close analysis through TOC and

304

conductivity measurements showed some trapped CC at the interfacial ice layer.

14 ACS Paragon Plus Environment

of water upon CC-EG

Page 14 of 33

Page 15 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

305

306 307

Figure 4: (a&b) Water flux using CC-EG & CC-Gly as DS and simulated standard MgSO4

308

and NaCl (2000 ppm) solutions as FS, respectively and (c&d) give flux data for seawater

309

(collected form Gujarat coast) and locally sourced brackish water, respectively. (e)

310

Photograph of phase separated water and DES portion when chilled post FO brackish water

311

desalination and concentration of their constituents. (Pristine CC-EG 1:2 mol ratio was used

312

as DS)

313 314

Overall estimation of contaminants in feed, diluted draw solution, and recovered product

315

water shows good water quality. In-sets in Figure 4e and Table 1 shows the concentration of

316

various ions in feed and recovered product water from diluted CC-EG. Higher concentration

317

of chloride ions is attributed to entrapped CC in the segregated ice. The product water

318

recovered (after FO process using seawater as feed solution) from diluted draw solution

319

shows higher TDS making it unsuitable for drinking purpose. Hence, generating drinking

320

water from seawater by FO process may be not a viable option keeping in mind the high

15 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 33

321

energy input. However, production of industrial grade water and irrigation water are the

322

feasible options in the desalination process of seaweed using FO.

323

Table 1. The composition of initial feed brackish water (BW) and sea water (SW) and final

324

desalinated product water recovered from draw solution (CC-EG) upon chilling. Feed Solution (mg/L)

Recovered Water from DS (mg/L)

Constituent +

Na K+ Mg2+ Ca2+ Cl-

Brackish Water 1179 31 477 903 5650

Sea Water 11800 900 1103 600 19600

Product water-BW 18 4.0 2.5 4.1 1843

Product water-SW 800 ND 100 50 10600

325 326

Recovery of reusable water from Tannery wastewater and dye contaminated water using

327

DES as Draw solution

328

Simulated dye wastewater comprising of 20 ppm RB5 was employed as a model feed

329

solution to test the efficiency of CC-EG as DS. The results indicated stable flux of ~ 5 LMH

330

upto 12 hours under no external pressure stimuli. The concentration of dye was quantified

331

with respect to the run-time of FO experiment and shows an almost linear increase till 10 h

332

(Figure 5a). Water recovery of ca. 80% was achieved and the diluted DS was chilled to -5ºC

333

to phase separate waster and recovered DES (Figure 5d). The as recovered DES was

334

subjected to another FO run with the same feed solution and showed similar flux results

335

(Figure 5b). It can be noticed that during the second run, the flux became identical in value to

336

that of first cycle after 5 hours of operation. It is safe to say that the recovered DES has some

337

level of water as impurity and is not as effective as pristine DES in terms of water activity

338

which in turn affects the dewatering capacity of recovered DES.

16 ACS Paragon Plus Environment

Page 17 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

339

340 341

Figure 5: (a) Flux and concentration profiles with simulated dye solution as FS and CC-EG

342

as DS (inset is the UV spectra for initial FS, final FS and diluted DS), (b) Flux recovery in

343

the second cycle with regenerated DS, (c) Picture showing initial and final FS and DS, (d)

344

Phase separation of water (ice) and DES (liquid) on cooling. (Pristine CC-EG 1:2 mol ratio

345

was used as DS)

346

Further, DES (CC-EG) was used as effective draw agent in FO for recovering high-

347

quality reusable water and simultaneously concentrating high-value products in tannery

348

wastewater. Generally, tannery wastewater can be termed as ‘dirtiest water’ because of the

349

nature of contaminants involved. Pressure-driven membrane processes have shown limited

350

potential to treat tannery wastewater so far. Moreover, pre-treatment is an unavoidable step to

351

protect the membrane from potential and drastic fouling under pressure. Unlike conventional

352

pressure-driven separation processes, FO offers greater benefits towards achieving zero waste

353

disposal and high-quality reusable product water. To the best of our knowledge, the FO study

354

presented herein is first of its kind effort towards obtaining high-quality reusable water and

355

achieving zero liquid disposals from real tannery wastewater. Direct concentration of tannery

356

feed wastewater may significantly contribute to the handling of toughest wastewater related 17 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

357

issues. In this direction, tannery effluent was circulated on the active layer of TFC membrane

358

against draw solution (CC-EG). Two types of effluents were employed in the current study,

359

(1) pre-treated, organics-free liquid discharge with TDS as high as 60,000 ppm and (2)

360

simulated tannery wastewater comprising of concentrated powder extracts of real tannery

361

effluents namely polyphenol, phenol-HCHO, red brown dye and ~2000 ppm NaCl in 1000

362

mL water.

363

Figure 6(a1-a4&b) shows photographs of lab scale FO experiment depicting one complete

364

cycle of high-quality water recovery from simulated tannery wastewater. CC-EG dewatered

365

>90% reusable water at a rate of ~3.2 -1.8 L.m-2.h-1 from simulated tannery wastewater over

366

a period of 12 hours (Figure S4), leaving behind concentrated contaminants. In addition to

367

this, DES was recovered following similar protocol (Figure 6b) and was tested against

368

simulated tannery feed for the second cycle. The flux trend coincides with the first cycle’s

369

flux values after 6 h of FO run (Figure S4), corroborating the flux variations observed for dye

370

wastewater runs. Further, Figure 6(c) shows osmotic flux trend recorded for liquid tannery

371

wastewater feed and CC-EG as draw solution, in this case an average osmotic flux of~1.5

372

L.m-2.h-1 was recorded for all the runs with recycled DES (2nd- 4th runs). The initial flux

373

trend (1st run) for pristine DES varied between ~ 2 - 1.25 L.m-2.h-1 over a period of 12 h of

374

FO run showing that the recovered DES has the capacity to regenerate its water

375

activity/osmotic pressure for continuous FO cycles. A water recovery of ca. 50% was

376

achieved and the constituents of initial and final solutions were quantified using ICP-OES

377

(Figure 6d). It can be concluded from the results that apart from Cl-, none of the cationic

378

species showed any significant crossover to the draw side. It should also be emphasized that

379

the ionic contaminants in the diluted DS tends to partition in the DES phase rather than the

380

icy water after phase separation. This can be seen in the distribution of contaminants in

381

recovered water and recovered DES. In case of simulated effluent, after ~90% dewatering,

18 ACS Paragon Plus Environment

Page 18 of 33

Page 19 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

382

concentrated feed and diluted draw were analyzed for concentration and possible crossover.

383

Figure 6e-f shows concentration distribution of different constituent in initial feed,

384

concentrated feed, recovered water and regenerated draw solution. The UV-visible spectral

385

trend near 275 nm and ~460 nm clearly indicates colorless diluted draw solution, whereas

386

estimation of recovered product water reveals insignificant crossover of NaCl. The feed

387

concentration of NaCl increased from 786 mg.mL-1 initial to 2732 mg.L-1 and diluted DS

388

showed~270 mg.L-1. But in all cases, no color was detected in diluted draw solution and

389

product water.

390

391

392 393

Figure 6: (a1-a4) Photographs of FO experiments of tannery wastewater treatment showing

394

initial feed, intermediate FO operation and product water recovery and concentrated draw

395

(CC-EG) recovery, respectively, (b) shows frozen diluted draw solution with separation

396

specifications, (c) flux trend using pristine CC-EG and performance of recovered draw

397

solution for three repeated fresh feed experiments. (d) The concentration of feed before and 19 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

398

after reusable water recovery. (b) UV-Vis spectra of initial feed, concentrated feed, product

399

water and recycled CC-EG layer, and (f) overall performance from experiments using real

400

tannery waste constituents. (Pristine CC-EG 1:2 mol ratio was used as DS)

401

DES recovery after FO and role of excess thermodynamic functions

402

The colligative property of a solution depends on the number of solvent molecules accessible

403

in that solution. The properties of DESs with addition of water were studied by monitoring

404

changes in the thermodynamic and physicochemical properties of CC-EG-water and CC-Gly-

405

water mixtures as a result of dilution (Figure 2). Here we demonstrated potential applications

406

with case studies that DES can be used effectively and efficiently for dewatering and

407

concentration of waste purposes. In both desalination and wastewater treatment cases, we try

408

to demonstrate a viable recovery method following solid-liquid phase separation of diluted

409

draw solution by freezing. Energy benefits from freezing diluted DES to recover product

410

water and reusable DS compared to pressure driven processes and other FO systems are very

411

significant. Generally, diluted draw solutions are being heat treated to recover draw solute

412

and collect product water or to condense pure water [26]. Freezing 1 Kg of water around -5°C

413

takes ~0.8 MJ which is 3 times less than evaporating the same (See supporting information

414

for details). Freezing may thus be considered as an energy less step for recovery of draw

415

solution with additional benefit of no loss in product water due to undesirable evaporation, a

416

common problem where DS recovery is brought about by elevated temperatures [56]. With

417

appropriate process design and better membranes, DESs can be an economically viable draw

418

solution. As the solid-liquid phase separation on freezing DES-water mixtures have not been

419

reported earlier and bring many questions to counter regarding the change in thermodynamic

420

properties at lower temperatures. These thermodynamic understandings may well be the basis

421

for designing effective draw recovery system. Isobaric thermal expansion coefficients, the

422

fractional change in volume that accompanies a rise in temperature (αp) for CC-EG is

423

reported to vary from ~0.525*103/K-1-0.550*103/K-1 as the temperature is decreased from 20 ACS Paragon Plus Environment

Page 20 of 33

Page 21 of 33

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Industrial & Engineering Chemistry Research

424

298.15K to 250 K and for CC-Gly it is even lower, ~0.450*103K-1[52]. A small value of αp

425

means that the volume of the sample responds weakly to changes in temperature. To the best

426

of our knowledge, there are no reported values of ρ and αp of DES at low temperatures. So,

427

we extrapolated these results (they all show linear dependency) to low temperature values to

428

understand the phase separation mechanism (Figure S5) [57-59]. At temperatures around -

429

7°C, the density of pure water is 0.998899 g.mL-1[61] and that of pure DES will be around

430

1.13 g.mL-1& 1.2 g.mL-1 for CC-EG and CC-Gly respectively [58-59]. When the diluted DES

431

(DS) was kept in a freezer at -7°C there is a sudden change in the surrounding temperature

432

(drop from 298 K to 266K) which results in entrapment of DES molecules in the ice crystal

433

structure. Gradual cooling was also attempted by first keeping the diluted DS at ~3-5 °C in a

434

normal refrigerator for 1 hour and then transferring it to deep freeze at -7 °C for 3 hours. The

435

final product water in later case was characterized by lower chloride ion concentration (500

436

ppm to 1000 ppm). A shift of negative excess functions to positive values for DES- Water

437

mixtures can be observed as the temperature decreases, which points towards a diminished

438

DES-Water interaction which facilitates the phase separation at sub-zero temperature [52].

439

Density difference is not the only property responsible for this separation; change in excess

440

molar volumes of the mixture also plays an important role. DES synthesis using HBD and

441

HBA dissolved in aqueous phase has been reported where freeze drying technique was

442

employed to remove water and obtain pure DES [62]. Although this study confirms the

443

possibility of extracting DES from aqueous systems, much work needs to be done in this

444

direction to minimize the loss of DS and production of high quality water from difficult FS.

445

In addition to regenerating potentials, CC-EG and CC-Gly solutions exhibit low toxicity and

446

effective multiple recovery cycles over other tested ionic liquids. Table 2 shows list of ionic

447

liquids used as draw solution in FO process in comparison to the present study. Retaining

448

high osmotic pressure which is evident from repeated cycle test are added advantages. 21 ACS Paragon Plus Environment

Industrial & Engineering Chemistry Research

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 33

449

However, energy efficiency in recycling diluted draw solution and cost comparison to present

450

competitive process, RO requires an extended technology evaluation. Nevertheless,

451

observation in this study highlights potentials of eutectic solvents as easily recyclable and

452

reusable draw solution for wide range of FO applications.

453

Table 2. Comparison with already reported Ionic Liquid Draw Solutions for FO applications Draw Solution

Properties

Flux

Recovery Experimental Membran Refn

(LMH) 3.2 M protonated betaine bis(trifluoromethylsulfon yl)imide ([Hbet][Tf2N]) in water

UCST-type IL immiscible with water at room temperature 1) Tetrabutylphosphoniu LCSTm 2,4immiscible dimethylbenzenesulfon with water ate (P4444DMBS) at elevated 2) Tetrabutylphosphoniu temperatures m mesitylenesulfonate (P4444TMBS) 3) Tributyloctylphosphonium bromide (P4448Br) 1) Choline ChlorideEthylene Glycol 2) Choline ChlorideGlycerol

Miscible with water in all ratios (25°C) Phase separation (ice and liquid DES) at ~-7°C

Conditions

0.50LMH with Cooling the Experiments were 0.6 M NaCl as diluted DS carried out at 60feed (sea water to 23 °C 80 °C concentration)

Feed-= 0.6 M NaCl solution P4444DMBS: