(46) J. Bouche and M. Verzele, J. Gas Chromatogr., 6, 501 (1968). (47) E. L. Ilkova and E. A. Mistryukov, J. Chromatogr. Sci., 9, 569 (1971). (48) J. Novak, V. Vasak, and J. Janak, Anal. Chem., 37, 660 (1965). (49) M. J. Hartigan, J. E. Purcell, M. Novotny, M. L. McConnell, and M. L. Lee, J. Chromatogr., 99, 339 (1974). (50) M. Novotny, M. P. Maskarinec, A.T.G. Steverink, and R. Farlow, Anal. Chem., 48,468(1976). (51) M. L. McConnell and M. Novotny, J. Chromatogr., 112,559(1975). (52) M. Hrivnac, W. Frischknecht, and M. Cechova, Anal. Chem., 48, 937 (1976). (53) B. Brechbuehler, L. Gay, and H. Jae ger, Chromatographia, 10, 478 (1977). (54) H. H. Hausdorff, J. Chromatogr., 134, 131 (1977). (55) S. Weinstein, B. Feibush, and E. GilAv, ibid., 126, 97 (1976). (56) G. M. Janini, G. M. Muschik, J. A. Schroer, and M. L. Zielinski, Jr., Anal. Chem., 48,1879 (1976). (57) W. A. Koenig and G. J. Nicholson, ibid., 47,951(1975). (58) M. Novotny, R. Segura, and A. Zlatkis, ibid., 44,9(1972). (59) M. Novotny, M. L. Lee, and K. D. Bartle, J. Chromatogr. Sci., 12, 606 (1974). (60) M. L. Lee, K. D. Bartle, and M. No votny, Anal. Chem., 47, 540 (1975). (61) M. L. Lee, M. Novotny, and K. D. Bartle, ibid., 48, 405 (1976). (62) M. L. Lee, M. Novotny, and K. D. Bartle, ibid., ρ 1566. (63) M. Novotny and M. L. Lee, Experientia, 29,1038(1973).
(64) W. Bertsch, R. C. Chang, and A. Zlatkis, J. Chromatogr. Sci., 12,175 (1974). (65) E. R. Adlard, L. F. Creaser, and P.H.D. Mathews, Anal. Chem., 44, 64 (1972). (66) J. J. Franken and G.A.F.M. Rutten, in "Gas Chromatography 1972", S. G. Perry, Ed., p 75, Applied Science, Bark ing, England, 1973. (67) J. J. Franken and H. L. Vader, Chro matographia, 6, 22 (1973). (68) B. Dowty, D. Carlisle, J. L. Laseter, and J. Storer, Science, 187, 75 (1975). (69) K. Grob, Chromatographia, 8, 423 (1975). (70) K. Grob, J. Chromatogr., 84, 255 (1973). (71) K. Grob and G. Grob, ibid., 90, 303 (1974). (72) K. Grob, K. Grob, Jr., and G. Grob, ibid., 106, 299 (1975). (73) M. Novotny, in "Advances in Analyti cal Chemistry", D.F.S. Natusch, Ed., in press. (74) M. Novotny and A. Zlatkis, Chroma togr. Rev., 14,1 (1971). (75) M. Novotny and A. Zlatkis, J. Chro matogr. Sci., 8, 346 (1970). (76) J. A.Voellmin and H.-Ch. Curtius, Z. Klin. Chem. Klin. Biochem., 9, 43 (1971). (77) C. D. Pfaffenberger and E. C. Horn ing,./. Chromatogr., 112,581 (1975). (78) H. Jaeger, H. U. Kloer, and H. Ditschuneit, J. Lipid Res.. 17.185 (1976). (79) K. Tesarik, S. Ghyczy, and V. S. Pansare, Chromatographia, 4, 396 (1971). (80) C. D. Pfaffenberger, J. Szafranek, and E. C. Horning, J. Chromatogr., 126, 535 (1976).
TOTAL GLASS CAPILLARY COLUMN SYSTEM
(81) A. Zlatkis, W. Bertsch, H. A. Lichtenstein, A. Tishbee, F. Shunbo, H. Liebich, A. Coscia, and N. Fleischer, Anal. Chem., 45, 763 (1973). (82) M. Novotny, M. L. McConnell, M. L. Lee, and R. Farlow, Clin. Chem., 20, 1105(1974). (83) C. Jacobs, E. Solem, J. Ek, K. Halvorsen, and E. Jellum, J. Chromatogr., 143, 31 (1977). (84) E. Jellum, P. Storseth, J. Alexander, P. Helland, O. Stokke, and E. Teig, ibid., 126,487 (1976). (85) M. P. Maskarinec, G. Shipley, M. No votny, D. J. Brown, and R. B. Forney, Experientia, in press. (86) M. P. Maskarinec, G. Shipley, M. No votny, D. J. Brown, and R. B. Forney, submitted for publication. (87) E. C. Horning and M. G. Horning, J. Chromatogr. Sci., 9, 129 (1971). (88) C. C. Sweeley, N. D. Young, J. F. Hol land, and S. C. Gates, J. Chromatogr., 99, 507 (1974). (89) E. Jellum, P. Helland, L. Eldjarn, U. Markwardt, and J. Marhoefer, ibid., 112, 573 (1975) (90) M. L. McConnell, G. Rhodes, U. Wat son, and M. Novotny, submitted for pub lication. (91) K. D. Bartle, M. L. Lee, and M. No votny, Int. J. Environ. Anal. Chem., 3, 349 (1974). (92) M. Novotny, M. L. Lee, C.-E. Low, and A. Raymond, Anal. Chem., 48, 24 (1976). (93) F. Mueller and M. Oreans, Chromato graphia, 10, 473 (1977). (94) J. C. Giddings, Anal. Chem., 36, 1890 (1964). (95) M.J.E. Golay, Chromatographia, 6, 242 (1973). (96) T. Tsuda and M. Novotny, Anal. Chem., in press. (97) T. Tsuda and M. Novotny, submitted for publication. Presented at the Division of Analytical Chemis try, 174th Meeting, ACS, Chicago, 111., August 28-September 2,1977.
GLASS DRAWING MACHINE GDM-1: A wide selection for drawing conditions allows customized glass capillary tubings. Hard and soft glass tubing up to 8 mm O.D. can be drawn to a range of 0.1 mm. I.D. size.
COLUMN COATING UNIT MCT-1A: Utilized to CLEAN, DRY and COAT stationary phases uniformly on columns.
COLUMN HOLDERS CLH SERIES: A convenient way to protect, store, change and operate columns. The column holder incorporates built-in split ter/make-up gas systems.
ONLY SHIMADZU OFFERS THE TOTAL GLASS CAPILLARY COLUMN SYSTEMS
SHIMADZU SCIENTIFIC INSTRUMENTS, INC.
θ
Columbia, Maryland 21045 SHIMADZU SEISAKUSHO, LTD. Kyoto, Japan CIRCLE 195 O N READER SERVICE CARD
32 A · ANALYTICAL CHEMISTRY, VOL. 50, NO. 1, JANUARY 1978
M i l o s N o v o t n y is c u r r e n t l y a n asso ciate professor of c h e m i s t r y a t I n d i a n a University. His research i n t e r e s t s in clude gas c h r o m a t o g r a p h y , gas chro m a t o g r a p h y / m a s s s p e c t r o m e t r y , highp e r f o r m a n c e liquid c h r o m a t o g r a p h y , a n d applications of t h e s e m e t h o d s to biomedical a n d e n v i r o n m e n t a l p r o b lems.