Subscriber access provided by UNIVERSITY OF CONNECTICUT
Article
Effects of H2O on NO emission during oxy-coal combustion with wet recycle Zhijun Sun, Sheng Su, Jun Xu, Kai Xu, Song Hu, Yi Wang, Long Jiang, Ningning Si, Yingbiao Zhou, Syed Shatir A. Syed-Hassan, Anchao Zhang, and Jun Xiang Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.7b00897 • Publication Date (Web): 05 Jul 2017 Downloaded from http://pubs.acs.org on July 6, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
1
Effects
of
H2O
on
NO
Emission
during
Oxy-coal
2
Combustion with Wet Recycle
3
Zhijun Suna, b, Sheng Sua*, Jun Xua, Kai Xua, Song Hua, Yi Wanga, Long Jianga,
4
Ningning Sia, Yingbiao Zhoua, Syed Shatir A. Syed-Hassana, c, Anchao Zhangb, Jun
5
Xianga*
6
a. State Key Laboratory of Coal Combustion,School of Energy and Power
7
Engineering, Huazhong University of Science and Technology, Wuhan 430074,
8
China;
9
b. School of Mechanical and Power Engineering,Henan Polytechnic University,
10
Jiaozuo 454001, China
11
c. Faculty of Chemical Engineering, Universiti Teknologi MARA, 40450 Shah Alam,
12
Selangor, Malaysia
13
14
*Corresponding author: Jun Xiang, Sheng Su
15
Tel.: +86-27-87542417, Fax: +86-27-87545526
16
E-mail address:
[email protected] 17
[email protected] 18
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
19
ABSTRACT
20
This study investigated the characteristics of NO emissions during oxy-coal
21
combustion with wet-recycle, especially in the presence of high H2O concentrations.
22
The oxy-combustion was carried out using two types of coal, namely Leiyang (LY)
23
anthracite and Zhundong (ZD) bituminous coals, inside a 24kW drop tube furnace
24
under different O2/CO2/H2O atmosphere. The results showed that the NO conversion
25
increased with decreasing CO2 concentration from 70% to 30% and decreased with
26
increasing H2O concentration from 10% to 40%. Under the experimental conditions
27
employed in this study, the fuel-N conversion for both LY and ZD coals under the
28
oxy-coal wet recycled combustion was lower than that under the oxy-coal dry
29
recycled combustion. The results indicated that H2O and CO2 showed a competitive
30
effect on NO emissions though both of them have positive effect on NO reduction. In
31
order to investigate the effects of H2O/CO2 on recycled NO, oxy-coal combustion
32
experiments were also performed with the initial addition of NO concentrations of
33
900 ppmv. The results showed that NO reduction ratio in O2/CO2 was lower than that
34
in O2/CO2/H2O for both coals under our experimental conditions. It is believed that
35
the results of this study can provide some fundamental information on the effect of
36
H2O/CO2 on the characteristics of NO emissions during oxy-coal combustion with
37
wet-recycle.
38
Keywords:
39
Oxy-coal Combustion, NO, O2/ CO2/ H2O, Reburn, Drop Tube Furnace
40
ACS Paragon Plus Environment
Page 2 of 36
Page 3 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
41
1. INTRODUCTION
42
Coal-fired power plants are among the major producers of CO2 emissions, a
43
primary cause of global warming 1. Coal is expected to be the dominant source of heat
44
and power production in the foreseeable future in many countries, especially China,
45
India, and Australia
46
CO2 from coal combustion activities. Unfortunately, the removal of CO2 in the
47
traditional coal combustion process is ineffective and costly because of the low CO2
48
concentration (10%–15%) in flue gas
49
been proposed as an alternative because the flue gas mainly comprising CO2 and
50
steam is recycled, and a high concentration of CO2 can be attained. Many studies
51
9-15
52
to capture CO2.
53
2, 3
. Many efforts have been done to minimize the emission of
4-8
. Oxy-coal (O2/CO2 recycle) combustion has
3, 6,
have demonstrated that oxy-coal combustion is one of the most efficient methods
Given that coal-fired power plants are major producers of pollutants, especially 16
54
the NOx
, the NOx emission characteristics should also be clarified in oxy-coal
55
combustion before this technology can be applied industrially 17, 18. Many studies have
56
investigated the NOx emissions under simulative oxy-coal combustion conditions in
57
O2/CO2 atmospheres. Buhre et al.3, Chungen and Jinyue19, Normann et al. 14, Wall et
58
al. 9, 13, 20, MacDowell et al. 21, Scheffknecht et al. 22, and Stanger et al. 11 all reported
59
that a larger amount of NOx emissions could be reduced in the O2/CO2 atmospheres
60
than in that the traditional air combustion atmosphere, due to the thermal NOx was
61
reduced greatly for N2 was replace by CO2. Our previous studies 23, 24 have also come
62
to the same conclusions. However, most of these studies were mainly performed in
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
63
Page 4 of 36
O2/CO2 atmospheres without considering the effects of H2O. It is known that the oxy-coal combustion can be classified into wet recycle and
64 65
dry recycle according to the position of the recycle for the flue gas4,
25
66
researchers suggested that wet recycle with a higher energy efficiency is more
67
appropriate for oxy-fuel combustion26, 27. In oxy-coal combustion with wet recycle,
68
some studies showed that the steam volume concentration reaching up to 37 vol. % 28,
69
29
70
and it will be a major atmosphere in the combustion. Thus, the effects of the steam on
71
the NO emission in oxy-coal combustion with wet recycle should not be ignored.
. Some
. And Jiang et al.’s 30 studies showed that steam concentration can be as high as 45%
72
Moro et al. 31 studied the replacement of CO2 with 10% H2O in an entrained flow
73
reactor, and found that the emissions of NOx were lower than that in the air
74
combustion and oxy-coal combustion with dry recycle. Stadler et al.
75
H2O could inhibit the oxidation of intermediates to form NO during oxy-coal
76
combustion. Stewart et al.
77
oxy-fired 100 kW circulating fluidized bed combustor and found that the addition of
78
8% vol. H2O decreased the NOx emissions by up to 44%. Álvarez et al. 34 showed that
79
the NOx concentration was reduced by replacing CO2 with 5%, 10 % and 20% of H2O
80
in the oxy-coal combustion atmosphere, but found no relevant differences for the NOx
81
emissions at different steam concentrations. All these studies indicate that the steam
82
can also affect the NO emission remarkably, however the steam concentration in these
83
studies was mainly lower than 20% and the effects of the high concentration steam on
84
the NO emission is still unclear. Moreover, with the changing of steam concentration
33
32
showed that
studied the effects of steam on NOx formation in an
ACS Paragon Plus Environment
Page 5 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
85
in the wide range (0 - 45%), the H2O/CO2 mole ratio in the oxy-coal combustion
86
would change from about 0 to 1, or even more, and the effects of H2O and CO2 on
87
oxy-coal combustion respectively would change significantly. The major factor that
88
affects the NO emission may be various in a wide range of H2O/CO2 mole ratio. In
89
addition, it has been found that there are complex interactions between H2O and CO2
90
on the char structures under oxy-coal combustion conditions in our previous studies35,
91
36
92
the NO emission is still unclear. Therefore, the co-effects of steam and CO2 on the NO
93
emission in oxy-coal combustion with wet recycle should be further clarified
94
especially in a wide range of H2O/CO2 mole ratio.
, but whether there are interactions or not between the effects of H2O and CO2 on
95
This study estimates the characteristics of NO emissions under oxy-coal
96
combustion with wet recycle in a wide range of H2O/CO2 mole ratio in a drop tube
97
furnace (DTF). The NO emissions from coal combustion in air, O2/CO2, O2/CO2/Ar
98
and O2/CO2/H2O were investigated at 1573 K. To examine the effects of H2O/CO2 on
99
NO reburning process, the experiments were performed under NO initial
100
concentration of 900 ppmv (part-permillion by volume) in an O2/CO2/H2O
101
atmosphere with different H2O/CO2 molar ratios.
102
2. EXPERIMENTS AND METHODS
103
2.1. Fuel Samples
104
Two Chinese coals with different ranks, namely, anthracite coal from Leiyang,
105
Hunan Province (LY) and highly volatile bituminous coal from Zhundong, Xinjiang
106
Province (ZD), were used in this study. The coal samples were crushed and sieved
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
107
into particles with sizes of 74 µm to 105 µm. Table 1 analyzes the coal samples.
108
2.2 Test Facility
109
Figure 1 presents a schematic diagram of the experimental system, which mainly
110
includes a 24 kW drop tube furnace (DTF), a steam generator system, a coal and gas
111
supply system, and a flue gas monitoring system.
112
The DTF is a vertical tube furnace with the temperature range between 1100 K to
113
1700 K and heating rates of 104 K/s to 105 K/s. An alumina tube with a 2.2 m length
114
and 55 mm inner diameter was used as the DTF reactor. A U-tube manometer with a 6
115
mm inside diameter was used to monitor the inside pressure of the reactor. The
116
temperature in the furnace was measured using three alumina sheathed R-type
117
thermocouples inserted into the wall. Moreover, the temperature profile in the reactor
118
was calibrated before experiment. A 1.5-meter-long type S thermocouple (a steel
119
bushing with water-cooling) was used to calibrate the inside temperature profile of the
120
reactor. The thermocouple was inserted into the DTF reactor from its two ends
121
respectively. Nitrogen gas with two liters per minute (at room temperature) was used
122
during the calibration process. Figure 2 shows the steady temperature distributions
123
along the central axis of the reactor, demonstrating a good constant temperature zone
124
can be obtained in this experimental system.
125
The steam generation systems used in our previous works36 included a furnace
126
and a syringe pump. Deionized water was injected into the steam generator using a
127
syringe pump. The gasified steam was supplied into the DTF reactor by the carrier gas
128
(in the secondary oxidation stream). To convert all water into steam, the carrier gas
ACS Paragon Plus Environment
Page 6 of 36
Page 7 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
129
was heated to 673 K by the pre-heat furnace. To prevent the steam from condensing,
130
the gas pipeline was all coated with a heating jacket.
131
The flow rates of the gas during the experiments were controlled by mass flow
132
controllers, the gas was mixed before being fed into the furnace. A spiral feeder was
133
used to control the coal feeding. Table 2 shows the feeder rate error.
134
A flue gas analyzer (Nova plus, MRU Instruments Inc., Germany) was used to
135
measure the concentrations of NO (Chemiluminescent Detector), CO (Non-Dispersive
136
Infra-Red), and O2 (Chemiluminescent Detector). A paramagnetic oxygen analyzer
137
(BA4000, MRU Instruments Inc., Germany) was used for the conditions with high
138
concentration of O2. Table 2 shows the accuracy of the gas analyzer. To compare the
139
NO emissions between the oxy-coal combustion with wet recycle and dry recycle,
140
high-purity Argon was used as the balance gas in the outlet of the DTF to compensate
141
for the condensed steam under the wet oxy-coal conditions.
142
2.3 Experimental Conditions
143 144 145
Excess oxygen ratio ( α ) is an important factor that affects NO emissions. This factor is computed as following: α = O2 ar /O2 tr
(1)
146
where O2 ar and O2tr denote the actual and theoretical requirements of oxygen,
147
respectively. The oxygen concentration varies from 21 vol. % to 30 vol. %.
148
Coal burnout is another important factor to the credibility of experimental data.
149
In this study, the fly ash was collected from the exhaust gases by a quartz fiber filter
150
and the coal burnout rate was computed by ash tracer method37. The major types of
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 36
151
NOx are thermal and fuel NOx during coal combustion. However, generally, the
152
formation of thermal NOx is more than 1500℃38. Therefore, NO is mainly derived
153
from fuel-N for the experimental conditions. The conversion ratio from fuel-N to NO
154
can be calculated as follows 18:
155
CR = [C (NO)× V × P /(RT)] / [ M(fuel)× Y(N, fuel)/ M(N)] × 100%
(2)
156
where CR is the conversion ratio of fuel-N to NO, %; C(NO) is the concentration of
157
NO in the flue gas when that in the carrier gas is zero, ppmv; V is the volumetric flow
158
rate of gases, m3/min; P is the system pressure, Pa; R is the ideal gas constant,
159
J/(mol•K); T is the absolute temperature of flue gas, K; M(fuel) is the mass flow rate of
160
fuel, g/min; Y (N, fuel) is the mass fraction of nitrogen in the fuel; and M(N) is the
161
atomic weight of nitrogen.
162
To investigate the effect of CO2/H2O on NO reburning process during the coal
163
combustion, several experiments were also performed with a concentration of 900
164
ppmv NO in O2/CO2/H2O atmospheres. After addition of NO to the inlet gas, the NO
165
will be partly reduced by reburning with coal18. The reduction ratio of NO to N2
166
without NO addition, with NO addition and recycled NO can be computed by Eq. (3a),
167
Eq. (3b) and Eq. (3c), respectively.
168
RR1=1-CR
(3a)
169
RR2=1-NOC3/ (NOC1+ NOC2)×100%
(3b)
170
RR3=(NOC1+NOC2-NOC3)/ NOC1×100%
(3c)
171
where RR1,RR2,RR3,denote the NO reduction ratio without NO addition, with NO
172
addition and recycled NO, respectively; NOC1 denotes the initial NO concentration
ACS Paragon Plus Environment
Page 9 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
173
added to the inlet gas, NOC2 denotes the NO concentration in the exhaust gas without
174
NO addition to the inlet gas; and NOC3 denotes the NO concentration in the exhaust
175
gas when the initial NO is 900 ppmv.
176
To minimize experimental error, a continuous online measurement was
177
performed thrice for each condition. The calculated NO concentration is the average
178
of thrice measurements. The calculated NO concentration is the average of three
179
measurements, the error bar shows the maximum different from the average value.
180
The experiments were operated at a constant temperature of 1573 K. Table 3 shows
181
the experimental conditions. In this table, H2O/CO2 was the ratio of initial
182
concentration for H2O and CO2, and it was just used as a reference condition to
183
express the effect of H2O on NO emission more exactly. For each run in drop tube
184
furnace, coal was entrained by 0.6 L/min primary gas and was fed at a rate of range
185
0.24 to 0.64 g/min according to the variety of excess oxygen ratio and coal type. The
186
secondary gas was introduced at a flow rate 1.4L/min that was heated and mixed in
187
the steam generator. The average residence time of coal particle in the reactor is about
188
0.8s.
189
3 RESULTS AND DISCUSSION
190
3.1 Effects of Excess Oxygen Ratios on NO Emissions
191
Figure 3 shows the changes in the conversion ratio from fuel-N to NO (CR) for
192
the LY and ZD coals under the oxy-coal conditions with increasing the excess oxygen
193
ratio (α). The burnout rate for ZD coal is more than 95% and for LY coal is between
194
85% to 90%. The value is similar for each coal in all experimental conditions. It can
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
195
be found that the CR under the air condition is higher than that under the oxy-coal
196
conditions for both coals. Moreover, under the oxy-coal conditions, the CR for both
197
coals increases along with α though the CR under these conditions is lower than that
198
under the air condition at the same α (1.3).
199
It can be also seen from Figure 3 that the ZD coal has a lower CR than the LY
200
coal under lower excess oxygen ratio conditions (α=1.1), and more fuel-N convert to
201
NO for ZD coal than LY coal. This may be due to the ZD coal has a much higher
202
volatile releasing than the LY coal, and most NO can be reduced by the homogenous
203
reduction for the ZD coal. However, as α increase, the NO emission shows the
204
opposite trend compared with the lower α condition for both coals, and the CR for the
205
ZD coal is higher than that for the LY coal. Moreover, with the increasing of α, the
206
volatile releasing for the ZD coal is much faster than that for the LY coal, and more
207
fuel-N is released and oxidized to NO under a rich oxygen atmosphere.
208
3.2 Effects of CO2 on NO Emissions
209
Figure 4 shows the effect of CO2 on CR for the LY and ZD coals. The burnout
210
rates for both coals are similar with that in section 3.1 conditions. The NO conversion
211
decreases along with the increasing mole fraction of CO2 for both coals. According to
212
our previous studies36, an increase in CO2 concentration can significantly enhance the
213
gasification reaction of CO2 with char to form more carbon monoxides and a large
214
amount of hydrocarbons are released at the beginning of coal combustion, all of these
215
will accelerate NO reduction. The possible NO reduction mechanism under high CO2
216
concentrations may include the following 39, 40:
ACS Paragon Plus Environment
Page 10 of 36
Page 11 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
217
CO2+H→CO+OH
(R1)
218
CO2+CH→CO+HCO
(R2)
219
NO + CO→1/2N2+CO2
(R3)
220
2NO+4H→N2+2H2O
(R4)
221
NO+CHi→XN (HCN & NH3) +CO+CO2
(R5)
222
C+NO→N2+CO2 or CO
(R6)
223
According to the above reactions, the homogeneous reduction of NO was mainly
224
induced by R1 to R5 at the beginning of the combustion, while the heterogeneous
225
reduction of NO was induced by R6 where NO was reduced at the char surface after
226
the devolatilization of coal.
227
Figure 4 shows that the CO2 concentration has a significantly different effect on
228
the CR for both coals. Increasing the CO2 molar fraction from 30% to 70% decreased
229
the CR for the LY and ZD coals by 6% and 20%, respectively. The pyrolysis and
230
gasification rates of the higher rank coal were slower than those of the lower rank
231
coal41. And the ZD coal also has a higher hydrogen content than the LY coal. More H,
232
CHi radical groups, and CO will be produced for NO reduction according to R2 to
233
R5.
234
3.3 Effects of H2O and H2O/CO2 on the NO Emissions
235
Increasing the H2O concentration will decrease the CO2 concentration in the H2O
236
and CO2 mixture when the total volume of the mixed gases remains unchanged. The
237
analyses in the section 3.2 reveal that decreasing the CO2 content will increase the CR.
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 12 of 36
238
In the experimental conditions, the coal burnout rate is similar to the value mentioned
239
in the previous sections. Figure 5 shows the decrease in CR with different additions of
240
H2O. Increasing the H2O mole fraction will further decrease the CR for both coals.
241
Apart from the gasification reactions, the addition of H2O to the diluent gas produces
242
the following reactions 40:
243
O+H2→H+OH
(R7)
244
H2O→H+OH
(R8)
245
OH+CO→CO2+H
(R9)
246
OH+H2→H2O+ H
(R10)
247
NO+H→HNO
(R11)
248
CO+HNO→CO2+NH
(R12)
249
HNO+NH→N2+H2O
(R13)
250
R7 to R10 show that more OH and H groups will be produced as the H2O mole
251
fraction increases, but the OH groups will be consumed by the gasification of coal.
252
The NO will be reduced by R11 to R13.
253
Based on CO2 as diluent gas condition, Figure 6 shows the comparison of the
254
effects of the increase of H2O and the decrease of CO2 on the change of CR. As the
255
percentage of CO2 in the gas mixture decreases, the change of CR decreases for the
256
two types of coal. At different CO2 concentrations, the change of CR showed higher
257
values for the ZD coal type while the values of LY coal type are less. Regarding the
258
effect of water vapor, it is clear that the change of CR is directly proportional to the
259
water vapor concentration. In addition, ZD coal type showed high values of CR
ACS Paragon Plus Environment
Page 13 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
260
change at different CO2 concentrations compared to LY coal type.
261
Figure 7 shows the combined effect of H2O and CO2 on CR under different
262
H2O/CO2 molar ratios. The CR for each type of coal significantly differs as the
263
H2O/CO2 molar ratio increases. The CR in the O2/H2O/CO2 condition is lower than
264
that in the O2/CO2 condition for both coals. Under the O2/H2O/CO2 condition, the CR
265
for the LY coal decreased as the H2O/CO2 molar ratio changed from 0:70 to 30:40,
266
and then increased as the H2O/CO2 molar ratio increased to 40:30. Meanwhile, the CR
267
for the ZD coal reached its lowest level at a H2O/CO2 molar ratio of 10:60, and then
268
gradually increased along with the H2O/CO2 molar ratio.
269
According to our previous study36, H2O and CO2 show a competitive relationship
270
with coal char during their co-gasification. The formation of NO from fuel-N can be
271
reduced by the carbon hydrogen radicals. For the LY coal, as Arenillas et al.
272
reported that the fuel type NOx was mainly derived from coal char-N for a high order
273
coal. Increasing the H2O/CO2 molar ratio will promote the gasification reaction,
274
producing more CO, which will reduce the number of OH atomic groups according to
275
the reaction R9. Both of these reactions have a positive effect on NO reduction.
276
Therefore, the CR decreases as the H2O/CO2 molar ratio increases from 0:70(dry) to
277
30:40. More oxidation groups, including OH groups, will be formed as the H2O/CO2
278
molar ratio further increases. According to Le Cong and Dagaut
279
increase along with the H2O concentration because of the H2O with O group
280
decomposition. Therefore, high concentration OH radicals will increase the
281
consumption of CO, decrease the NO reduction, and increase the CR.
ACS Paragon Plus Environment
42
43
, the OH radicals
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
282
Table 1 shows that the volatile, hydrogen, and oxygen content in the ZD coal are
283
much higher than that in the LY coal. Moreover, the ZD coal has a much easier
284
pyrolysis and gasification than the LY coal. Therefore, the NO formation and
285
reduction of the ZD coal significantly differ from those of the LY coal. Combining
286
Figures 6 and Figure 7, the lowest CR was obtained for ZD coal at 10% H2O/CO2
287
molar ratio, but the lowest CR was obtained for LY coal at 30% H2O/CO2 molar ratio.
288
As a lower order coal, the ZD coal mainly generates NO from the conversion of
289
volatile-N
290
molar ratio according to R1 and R7. Meanwhile, R8 and R9 show that the increasing
291
H2O addition will produce more mole fractions of H, O, and OH in the H2O condition
292
than in the CO2 condition
293
groups. At the same time, the O content of the ZD coal is higher than that of the LY
294
coal, thereby allowing the ZD coal to form OH groups. As shown in sections 3.2 and
295
3.3, the increasing H2O has a negative effect on NO formation for the ZD coal, while
296
the decreasing CO2 shows an opposite effect. Moreover, decreasing the CO2
297
concentration in H2O/CO2 has a much greater effect on NO formation than increasing
298
the H2O concentration. Therefore, the CR for the ZD coal increases along with the
299
H2O/CO2 mole fraction.
44
. The concentration of OH groups increases along with the H2O/CO2
45
, thereby increasing the CO consumption of the OH
300
An optimal H2O/CO2 molar ratio that corresponds to a minimum NO conversion
301
rate may exist. However, different coals have varying molar ratios. Specifically, the
302
LY coal has a 30:40 molar ratio, while the ZD coal has a 10:60 molar ratio. Such
303
differences may be explained by the H2/CO ratios, for the H2/CO ratios will change
ACS Paragon Plus Environment
Page 14 of 36
Page 15 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
304
for different coal gasification at different H2O/CO2. In sum, for the wet oxy-coal
305
combustion, different types of coal may show optimal H2O/CO2 ratios corresponding
306
to a minimized NO CR, but the corresponding mechanism requires verification by
307
further investigation.
308
3.4 Influence of Initial NO Concentration on NO Reduction
309
Reburning nitrogen oxides in oxy-coal combustion is an important method for 46-48
310
reducing NO
. In the wet oxy-coal combustion, apart from the influence of
311
H2O/CO2 on the conversion of fuel nitrogen to NO, the NO reduction in the recycled
312
flue gas may also may be affected by H2O/CO2.
313
Figure 8 shows the reduction ratios of NO without NO addition (RR1), with NO
314
addition (RR2) and recycled NO (RR3) at different H2O/CO2 molar ratios, respectively.
315
For the LY coal, the RR1 increases as the H2O/CO2 molar ratio changes from 0:70 to
316
30:40, and then decreases as the molar ratio increases from 30:40 to 40:30. With the
317
change of H2O/CO2 molar ratio, RR1 shows the opposite trend with the CR. The RR2
318
and RR3 showed the same trend as that without NO added conditions. For the ZD coal,
319
the maximum reduction ratio can be obtained at a 10:60 H2O/CO2 molar ratio for both
320
with and without NO conditions. The maximum recycled NO reduction ratio can be
321
achieved at a 10:60 H2O/CO2 molar ratio. Figure 8 also shows that the reduction
322
ratios with NO added condition for both coals are lower than that without NO added
323
conditions. According to sections 3.2 and 3.3, the mechanism of NO reduction can be
324
explained by the reaction R1 to R12, the reduction ratios showed the different trends
325
with the change of H2O/CO2 molar ratio for both coals. In general, the NO reduction
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
326
ratio will increase with the increase of the reactant (initial NO concentration), but in
327
fact, the results showed the contrary trend. This can be explained by considering that
328
the NO reduction ability (the reduction groups such as H, CHi, CO, etc. is limited) is
329
greatly reduced especially in the presence of excess oxygen. Therefore, the reduction
330
ratio with NO addition conditions is lower than that without NO added conditions at
331
experimental conditions.
332
4. CONCLUSIONS
333
The NO emission behavior in oxy-coal combustion with wet recycle conditions
334
was tested in a DTF at 1573 K. The effects of excess oxygen ratio, CO2, H2O,
335
H2O/CO2, and addition of initial NO on the NO emissions were studied. The
336
following results were obtained:
337
(1) Excess oxygen ratio is a main contributor of NO emissions. As the excess
338
oxygen ratio increases, more fuel-N will be converted to NO. The conversion ratio
339
under the oxy-coal conditions is lower than that under the air condition.
340
(2) A higher CO2 concentration contributes to a lower NO emission in oxy-coal
341
combustion for both LY and ZD coals. In oxy-coal with dry recycled combustion, the
342
NO conversion ratio increases as the CO2 concentration decreases. CO2 produces a
343
greater effect on the conversion of NO to N2 for the low ranking coal.
344
(3) The he NO conversion ratio for both LY and ZD coals under the oxy-coal with
345
wet recycled combustion is lower than that under the oxy-coal with dry recycled
346
combustion. The experimental results showed that H2O has a positive effect on NO
347
reduction. The NO further reduces as the H2O content increases under the
ACS Paragon Plus Environment
Page 16 of 36
Page 17 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
348
experimental conditions. H2O and CO2 show a competitive effect on NO formation
349
and reduction under the H2O/CO2 conditions.
350
(4) The reduction ratio decreases after the initial NO addition of 900 ppmv. The
351
H2O/CO2 molar ratio has no relevant effect on NO emission under the experimental
352
conditions.
353
ACKNOWLEDGMENTS
354
This work was sponsored by the National Natural Science Foundation of China (NO.
355
51576081, 51576086, 51576072, 51676064) and the National Key Research and
356
Development Program of China. Technical supports from the Analytical and Testing
357
Center of Huazhong University of Science and Technology are highly appreciated.
358
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
359 360 361
References (1) Haszeldine, R. S. Carbon capture and storage: how green can black be? Science 2009, 325(5948), 1647-1652.
362
(2) Châtel-Pélage, F.; Varagani, R.; Pranda, P.; et al. Applications of oxygen for
363
NOx control and CO2 capture in coal-fired power plants. Therm Sci 2006, 10, (3),
364
119-142.
365
(3) Buhre, B. J. P.; Elliott, L. K.; Sheng, C. D.; et al. Oxy-fuel combustion
366
technology for coal-fired power generation. Prog Energy Combust Sci 2005, 31, (4),
367
283-307.
368
(4) Nakayama, S.; Noguchi, Y.; Kiga T.; et al. Pulverized coal combustion in
369
O2/CO2 mixtures on a power plant for CO2 Recovery. Energy Convers Manage 1992,
370
33, (5), 379-386.
371
(5) Wolsky, A. M.; Daniels, E. J.; Jody, B. J. Recovering CO2 from large−and
372
medium-size stationary combustors. J Air Waste Manage Assoc 1991, 41, (4),
373
449-454.
374
(6) Figueroa, J. D.; Fout, T.; Plasynski, S.; et al. Advances in CO2 capture
375
technology—the U.S. department of energy's carbon sequestration program. Int J
376
Greenh Gas Con 2008, 2, (1), 9-20.
377
(7) Liu, H.; Okazaki, K. Simultaneous easy CO2 recovery and drastic reduction of
378
SOx and NOx in O2/CO2 coal combustion with heat recirculation. Fuel 2003, 82, (11),
379
1427-1436.
380
(8) Liu, H.; Zailani, R.; Gibbs, B. M. Comparisons of pulverized coal combustion in
ACS Paragon Plus Environment
Page 18 of 36
Page 19 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
381 382
air and in mixtures of O2/CO2. Fuel 2005, 84, (7-8), 833-840. (9) Wall, T. F. Combustion processes for carbon capture. P Combust Inst 2007, 31,
383
(1), 31-47.
384
(10) Hu, Y.; Li, H.; Yan, J. Techno-economic evaluation of the evaporative gas
385
turbine cycle with different CO2 capture options. Appl Energ 2012, 89, (1), 303-314.
386
(11) Stanger, R.; Wall, T.; Spoerl, R.; et al. Oxyfuel combustion for CO2 capture in
387
power plants. Int J Greenh Gas Con 2015, 40, 55-125.
388
(12) Li, L.; Zhao, N.; Wei, W.; et al. A review of research progress on CO2 capture,
389
storage, and utilization in Chinese Academy of Sciences. Fuel 2013, 108, 112-130.
390
(13) Wall, T.; Liu, Y. H.; Spero, C.; et al. An overview on oxyfuel coal combustion -
391
state of the art research and technology development. Chem Eng Res Des 2009, 87,
392
(8), 1003-1016.
393
(14) Normann, F.; Andersson, K.; Leckner, B.; et al. Emission control of nitrogen
394
oxides in the oxy-fuel process. Prog Energy Combust Sci 2009, 35, (5), 385-397.
395
(15) Li, H.; Yan, J.; Anheden M. Impurity impacts on the purification process in
396
oxy-fuel combustion based CO2 capture and storage system. Appl Energ 2009, 86, (2),
397
202-213.
398
(16) Wang, C. A.; Du, Y.; Che, D. Study on N2O reduction with synthetic coal char
399
and high concentration CO during oxy-fuel combustion. P Combust Inst 2015, 35, (2),
400
2323-2330.
401
(17) Okazaki, K.; Ando, T. NOx reduction mechanism in coal combustion with
402
recycled CO2. Energy 1997, 22, (2-3), 207-215.
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
403
(18) Shaddix, C. R.; Molina, A. Fundamental investigation of NOx formation during
404
oxy-fuel combustion of pulverized coal. P Combust Inst 2011, 33, (2), 1723-1730.
405
(19) Yin, C.; Yan, J. Oxy-fuel combustion of pulverized fuels: combustion
406
fundamentals and modeling. Appl Energ 2016, 162, 742-762.
407
(20) Wall, T.; Stanger, R.; Santos, S. The current state of oxy-fuel technology:
408
demonstrations and technical barriers. In 2nd Oxyfuel Combustion Conference,
409
Queensland, Australia, 2011.
410
(21) MacDowell, N.; Florin, N.; Buchard, A.; et al. An overview of CO2 capture
411
technologies. Energ Env Sci 2010, 3, (11), 1645-1669.
412
(22) Scheffknecht, G.; Al-Makhadmeh, L.; Schnell, U.; et al. Oxy-fuel coal
413
combustion-A review of the current state-of-the-art. Int J Greenh Gas Con 2011, 5S,
414
S16-S35.
415
(23) Wang, B.; Sun, L. S.; Su, S.; et al. A kinetic study of NO formation during
416
oxy-fuel combustion of pyridine. Appl Energ 2012, 92, 361-368.
417
(24) Sun, Z. J.; Su, S.; Ning, X.; et al. The investigation of NOx formation and
418
reduction during O2/CO2 combustion of raw coal and coal char. Energy Procedia
419
2015, 66, 69-72.
420
(25) Zhou, W.; Moyeda, D. Process evaluation of oxy-fuel combustion with flue gas
421
recycle in a conventional utility boiler. Energy Fuels 2010, 24, (3), 2162-2169.
422
(26) Chen, L.; Yong, S. Z.; Ghoniem, A. F. Oxy-fuel combustion of pulverized coal:
423
characterization, fundamentals, stabilization and CFD modeling. Prog Energy
424
Combust Sci 2012, 38, (2), 156-214.
ACS Paragon Plus Environment
Page 20 of 36
Page 21 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
425
(27) Toftegaard, M. B.; Brix, J.; Jensen, P. A.; et al. Oxy-fuel combustion of solid
426
fuels. Prog Energy Combust Sci 2010, 36, (5), 581-625.
427
(28) Mao, Z.; Zhang, L.; Zhu, X.; et al. Modeling of an oxy-coal flame under a
428
steam-rich atmosphere. Appl Energ 2016, 161, 112-123.
429
(29) Hecht, E. S.; Shaddix, C. R.; Geier, M.; et al. Effect of CO2 and steam
430
gasification reactions on the oxy-combustion of pulverized coal char. Combust Flame
431
2012, 159, (11), 3437-3447.
432
(30) Jiang, Z.; Duan, L.; Chen, X.; et al. Effect of water vapor on indirect sulfation
433
during oxy-fuel combustion. Energy Fuels 2013, 27, (3), 1506-1512.
434
(31) Moroń, W.; Rybak, W. NOx and SO2 emissions of coals, biomass and their
435
blends under different oxy-fuel atmospheres. Atmospheric Environment 2015, 116,
436
65-71.
437
(32) Stadler, H.; Christ, D.; Habermehl, M.; et al. Experimental investigation of NOx
438
emissions in oxycoal combustion. Fuel 2011, 90, (4), 1604-1611.
439
(33) Stewart, M. C.; Symonds, R. T.; Manovic, V.; et al. Effects of steam on the
440
sulfation of limestone and NOx formation in an air-and oxy-fired pilot-scale
441
circulating fluidized bed combustor. Fuel 2012, 92, (1), 107-115.
442
(34) Álvarez, L.; Riaza, J.; Gil, M. V.; et al. NO emissions in oxy-coal combustion
443
with the addition of steam in an entrained flow reactor. Greenh Gases 2011, 1, (2),
444
180-190.
445
(35) Xu, J.; Su, S.; Sun, Z. J.; et al. Effects of steam and CO2 on the characteristics of
446
chars during devolatilization in oxy-steam combustion process. Appl Energ 2016, 182,
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
447
20-28.
448
(36) Xu, J.; Su, S.; Sun, Z. J.; et al. Effects of H2O gasification reaction on the
449
characteristics of chars under oxy-fuel combustion conditions with wet recycle.
450
Energy Fuels 2016, 30, (11), 9071-9079.
451
(37) Ballantyne T R, Ashman P J, Mullinger P J. A new method for determining the
452
conversion of low-ash coals using synthetic ash as a tracer. Fuel, 2005, 84(14):
453
1980-1985.
454
(38) Normann, F.; Andersson, K.; Leckner, B. et al. High-temperature reduction of
455
nitrogen oxides in oxy-fuel combustion. Fuel 2008, 87, (17-18), 3579-3585.
456
(39) Watanabea, H.; Marumob, T.; Yamamotoa, J. I.; et al. The effect of CO2
457
reactivity on NOx reduction in O2/CO2 combustion. In 2nd Oxyfuel Combustion
458
Conference, Queensland, Australia, 2011.
459
(40) Wang, Z.; Zhou, Y.; Whiddon, R.; et al. Investigation of NO formation in
460
premixed adiabatic laminar flames of H2/CO syngas and air by saturated
461
laser-induced fluorescence and kinetic modeling. Combust Flame 2016, 164, 283-293.
462
(41) A. Cuadrat; Abad, A.; García-Labiano, F.; et al. Relevance of the coal rank on
463
the performance of the in situ gasification chemical-looping combustion. Chem Eng J.
464
2012, 195, 91-102.
465
(42) Arenillas, A.; Rubiera, F.; Pis, J. J. Nitric oxide reduction in coal combustion:
466
role of char surface complexes in heterogeneous reactions. Environ Sci Technol 2002,
467
36, (24), 5498-5503.
468
(43) Le Cong, T.; Dagaut, P., Experimental and detailed modeling study of the effect
ACS Paragon Plus Environment
Page 22 of 36
Page 23 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
469
of water vapor on the kinetics of combustion of hydrogen and natural gas, impact on
470
NOx. Energy Fuels 2009, 23, (2), 725-734.
471
(44) Gao, J. S. Coal gasification. Coal, Oil shale, Natural Bitumen, Heavy Oil and
472
Peat- Vol. I, 380. Eolss Publishers: Paris, UNESCO, 2009.
473
(45) Park, J.; Kim, S. G.; Lee, K. M.; et al. Chemical effect of diluents on flame
474
structure and NO emission characteristic in methane-air counterflow diffusion flame.
475
Int J Energy Res 2002,26,(13), 1141-1160.
476
(46) Dao, D. Q.; Gasnot, L.; Marschallek, K.; et al. Experimental study of NO
477
removal by gas reburning and selective noncatalytic reduction using ammonia in a
478
lab-scale reactor. Energy Fuels 2010, 24, (3), 1696-1703.
479
(47) Normann, F.; Andersson, K.; Johnsson, F.; et al. Reburning in oxy-fuel
480
combustion: a parametric study of the combustion chemistry. Ind Eng Chem Res 2010,
481
49, (19), 9088-9094.
482
(48) Su, S.; Xiang, J.; Sun, L. S.; et al. Numerical simulation of nitric oxide
483
destruction by gaseous fuel reburning in a single-burner furnace. P Combust Inst 2007,
484
31, (2), 2795-2803.
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
485
List of tables
486
Table 1 Proximate and Ultimate Analytical Results of Tested Coal Samples (on the
487
basis of air-dried weight).
488
Table 2 Accuracies of the Measurements Uncertainties in the Results.
489
Table 3 Experimental Conditions.
490
ACS Paragon Plus Environment
Page 24 of 36
Page 25 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
491
Table 1
492
Proximate and Ultimate Analytical Results of Tested Coal Samples (on the basis of
493
air-dried weight). Proximate analysis (wt. %)
494
1.
Ultimate analyses (wt. %)
Sample
Moisture
Ash
VM
FC
C
H
N
S
O1
LY
3.59
34.46
5.68
56.27
56.97
1.95
0.75
0.51
1.77
ZD
12.47
4.64
25.78
57.11
61.45
4.29
0.46
0.42
16.27
calculated by difference.
495
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
496 497
Page 26 of 36
Table 2 Accuracies of the Measurements Uncertainties in the Results. 498 Accuracies and uncertainties 499 Fuels flow rate (g/h)
Uncertainty = ±1 %
Flow rate of syringe pump( ml/min)
Accuracy=±0.005
Temperature (K)
Accuracy = ±1
CO (vol. %)1
Accuracy = ±0.2
NO (ppmv)1
Accuracy = ±5
O2 (%)1
Accuracy = ±0.2
O2 (%)2
Accuracy = ±1
500 501 502 503 504 505 506 507 508 509
1 2
. Flue gas analyzer (Nova Plus, MRU Instruments Inc., Germany) . Paramagnetic oxygen analyzer (BA4000, MRU Instruments Inc., Germany)
ACS Paragon Plus Environment
Page 27 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
510 511
Table 3 Experimental Conditions. Conditions
Case 1
Case 2
Case 3
Case 4
Case 5
α
1.1-1.4
1.3
1.3
1.3
1.3
O2 (Vol. %)
30
30
30
21
30
CO2 (Vol. %)
70
/
/
/
/
N2 (Vol. %)
/
/
/
79
/
CO2/Ar (molar ratio)
/
30:40, 40:30,
/
/
/
10:60, 20:50,
/
10:60, 20:50,
50:20, 60:10, 70:0 H2O/CO2 (molar ratio)
/
/
30:40, 40:30 NO addition( (ppmv) )
/
/
/
512 513
ACS Paragon Plus Environment
30:40, 40:30 /
0, 900
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
514
List of Figure Captions
515
Figure 1. Schematic diagram of experimental apparatus. 1. Particle feeding element,
516
2. Water cooling, 3. Corundum tube, 4. Flue gas exit, 5. Gas analysis, 6. Drier, 7.
517
Filtration, 8. Cyclone, 9. Balance gas, 10. Mass Flowmeter, 11. U-tube manometer, 12.
518
Collection probe, 13. Electrical heating and temperature control elements, 14.
519
De-ionized water,15. Steam generator, 16. Gas mixer, 17. Gas cylinders
520
Figure 2. Temperature profiles within the reactor.
521
Figure 3. Average CR for the LY and ZD coals with varying excess oxygen ratios
522
(α).
523
Figure 4. Effect of CO2 on NO conversion ratio for the LY and ZD coals at different
524
mole fractions.
525
Figure 5. Decreased NO conversion ratio with different H2O content.
526
Figure 6.The change of NO conversion ratio based on CO2 as diluent condition
527
versus the varieties of Ar/CO2 and H2O/CO2.
528
Figure 7. NO conversion ratio for the LY and ZD coals in the O2/CO2 and oxy-coal
529
combustion with wet recycle experiments with various H2O concentrations.
530
Figure 8. NO reduction ratios for (a) LY coal and (b) ZD coal combustion with
531
various H2O/CO2 molar ratios with and without an initial NO addition of 900 ppmv.
532
ACS Paragon Plus Environment
Page 28 of 36
Page 29 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
533 534 535 536 537 538 539
1. Particle feeding element, 2. Water cooling, 3. Corundum tube, 4. Flue gas exit, 5. Gas analysis, 6. Drier, 7. Filtration, 8. Cyclone, 9. Balance gas, 10. Mass Flowmeter, 11. U-tube manometer, 12. Collection probe, 13. Electrical heating and temperature control elements, 14. De-ionized water,15. Steam generator, 16. Gas mixer, 17. Gas cylinders Figure 1. Schematic diagram of experimental apparatus.
540
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
541 542
Figure 2. Temperature profiles within the reactor.
543 544 545 546
ACS Paragon Plus Environment
Page 30 of 36
Page 31 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
547 548
Figure 3. Average NO conversion ratio for the LY and ZD coals with varying
549
excess oxygen ratios (α).
550
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
551 552
Figure 4. Effect of CO2 on NO conversion ratio for the LY and ZD coals at
553
different mole fractions.
554
ACS Paragon Plus Environment
Page 32 of 36
Page 33 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
555 556
Figure 5. Decreased NO conversion ratio with different H2O content.
557
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
558 559
560
561 562 563
Figure 6. .The change of NO conversion ratio based on CO2 as diluent condition versus the varieties of Ar/CO2 and H2O/CO2.
ACS Paragon Plus Environment
Page 34 of 36
Page 35 of 36
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Energy & Fuels
564 565
Figure 7. NO conversion ratio for the LY and ZD coals in the O2/CO2 and wet
566
oxy-coal combustion experiments with various H2O concentrations.
567
ACS Paragon Plus Environment
Energy & Fuels
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
568
569 570
Figure 8. NO reduction ratios for (a) LY coal and (b) ZD coal combustion with
571
various H2O/CO2 molar ratios with and without an initial NO addition of 900
572
ppmv.
ACS Paragon Plus Environment
Page 36 of 36