Assessment of Exposures to Acetamide in Milk, Beef, and Coffee Using Xanthydrol Derivatization and GC/MS Ramin Vismeh, Diane Haddad, Janette Moore, Chandra Nielson, Bryan D. Bals, Tim Campbell, Allen Julian, Farzaneh Teymouri, A. Daniel Jones, and Venkataraman Bringi J. Agric. Food Chem., Just Accepted Manuscript • DOI: 10.1021/acs.jafc.7b02229 • Publication Date (Web): 30 Nov 2017 Downloaded from http://pubs.acs.org on November 30, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Journal of Agricultural and Food Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 37
Journal of Agricultural and Food Chemistry
1
Exposure Assessment of Acetamide in Milk, Beef,
2
and Coffee Using Xanthydrol Derivatization and
3
GC/MS
4
Ramin Vismeh†, Diane Haddad†, Janette Moore†, Chandra Nielson†, Bryan Bals†, Tim Campbell†,
5
Allen Julian†, Farzaneh Teymouri†, A. Daniel Jones*‡,§, and Venkataraman Bringi#
6
†
7
8
‡
Department of Biochemistry and Molecular Biology, Michigan State University, East Lansing, Michigan, 48824, United States
9
10
§
Department of Chemistry, Michigan State University, East Lansing, Michigan, 48824, United States
11
12 13
14 15
Michigan Biotechnology Institute, Lansing, Michigan, 48910, United States
#
Department of Chemical Engineering and Materials Science, Michigan State University, East Lansing, Michigan, 48824, United States
* Phone: +1-517-432-7126; Fax: +1-517-353-9334; E-mail:
[email protected] 1 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
16 17
ABSTRACT
18
Acetamide has been classified as a possible human carcinogen, but uncertainties exist about its
19
levels in foods. This report presents evidence that thermal decomposition of N-acetylated sugars
20
and amino acids in heated gas chromatograph injectors contributes to artifactual acetamide in
21
milk and beef. An alternative GC/MS protocol based on derivatization of acetamide with 9-
22
xanthydrol was optimized and shown to be free of artifactual acetamide formation. The protocol
23
was validated using a surrogate analyte approach based on d3-acetamide, and applied to analyze
24
23 pasteurized whole milk, 44 raw sirloin beef, and raw milk samples from 14 different cows,
25
and yielded levels about 10-fold lower than obtained by direct injection without derivatization.
26
The xanthydrol derivatization procedure detected acetamide in every food sample tested, at 390
27
± 60 ppb in milk, 400 ± 80 ppb in beef, and 39000 ± 9000 ppb in roasted coffee beans.
28 29
Keywords:
analytical artifacts, food safety, method validation, N-acetylated sugars, surrogate
30
analyte validation, thermal degradation, acetamide
2 ACS Paragon Plus Environment
Page 2 of 37
Page 3 of 37
31
Journal of Agricultural and Food Chemistry
INTRODUCTION:
32
Acetamide is a simple amide with the chemical formula CH3CONH2 and is formed by the
33
dehydration of ammonium acetate, hydrolysis of acetonitrile, 1, 2 or ammonolysis of acetate esters
34
from plant cell walls. 3, 4 Acetamide has been classified by the International Agency for Research
35
on Cancer (IARC) as a Group 2B possible human carcinogen,5 as feeding trials on rats have
36
shown an increase in liver carcinoma.6,7 The simplicity of the molecule suggests that it may be
37
formed naturally or as a byproduct of other processes. Acetamide has been found in tobacco
38
smoke,8 industrial water9 and in beef and poultry liver.10,11 Two previous studies measured
39
acetamide in milk to determine exposure due to insecticides (thiodicarb and methomyl), and
40
surprisingly found acetamide in the milk of control animals as well.10-12 Furthermore, measured
41
acetamide levels in controls varied greatly between the two tests; in the methomyl it ranged from
42
2 - 8 ppm in milk, while only 0.3 – 0.5 ppm in the thiodicarb study. Both tests used GC to
43
measure the acetamide in milk, but neither report described the method validation in detail.
44
Artifacts may be anticipated during GC analysis of acetamide in foods, and particularly in milk
45
because of the abundance of N-acetylated (or acetamido) moieties on sugars, amino acid
46
metabolites and proteins. Commonly occurring N-acetylated compounds include the
47
monosaccharides N-acetylglucosamine and N-acetylneuraminic acid (commonly known as sialic
48
acid), and acetylated amino acids such as N-acetylcysteine. Furthermore, abundant glycoproteins
49
in milk including κ-casein and lactoferrin also contain N-acetyl sugars.13 A 2001 report14
50
measured N-acetylglucosamine and N-acetylgalactosamine in milk following brief ultra-high
51
temperature (~5 s at ~150 ˚C) pasteurization, and found combined levels of approximately 100
52
ppm. These N-acetylated compounds are potential sources of artifacts in acetamide analysis by
53
releasing acetamide. Further support for this idea comes from a recent NMR investigation of 3 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
54
products released from roasting chicory root, which demonstrated that levels of acetamide “were
55
dramatically increased” upon roasting to levels detectable using NMR spectroscopy.15
56
One may postulate that the presence of acetamide in milk, as well as the discrepancy between
57
the thiodicarb and methomyl studies, arises from the thermal breakdown of endogenous N-
58
acetylated metabolites and glycans into acetamide and the parent sugar molecule during
59
vaporization of milk extracts. 16 . For example, Köll et al.17 found that acetamide was the main
60
volatile degradation product resulting from the thermal decomposition of chitin, a polymer of N-
61
acetylglucosamine. Thermal degradation commenced at 200 ˚C, below the boiling point of
62
acetamide (221 ˚C). These results suggest that in hot (> 200 ˚C) GC injectors, N-acetylated
63
compounds decompose to form acetamide, and thus obscure accurate quantitation of native
64
acetamide.
65 66
Alternatives to hot GC injection have been considered, but can often result in other
67
disadvantages. In liquid chromatography, acetamide has low electrospray ionization efficiency
68
and it is challenging to retain and separate acetamide from a complex mixture using reverse-
69
phase HPLC columns. Elias et al. used HPLC-UV to quantitate acetamide in hydrogeothermal
70
waters.18 Although the reported detection limit for acetamide was low (7.7 ppb), acetamide peaks
71
were broad and showed minimal separation from other analytes in a water matrix, which is
72
considered less complex than food extracts. Furthermore, our initial investigations detected trace
73
levels of acetamide as a contaminant in HPLC-grade acetonitrile, and this finding steered us
74
away from using LC/MS for its analysis. To prevent possible artifact formation from thermal
75
degradation, Diekmann et al.8 used on-column (also known as cool-on-column) injection GC/MS
76
for measuring acetamide and acrylamide in cigarette mainstream smoke. Cool-on-column 4 ACS Paragon Plus Environment
Page 4 of 37
Page 5 of 37
Journal of Agricultural and Food Chemistry
77
injection is not applicable to all samples. In cool-on-column injection, everything in the extracts
78
is introduced into the column, and thus complex matrices have the potential to degrade
79
chromatographic performance. Extracts of food matrices probably need extensive cleanup before
80
injection to minimize irreproducibility and avoid long analysis times.
81
One approach to reduce matrix effects and artifacts in direct GC injection is to derivatize
82
acetamide before injection. In 2013, Cho and Shin19 successfully used derivatization with 9-
83
xanthydrol to measure acetamide in drinking water. 9-Xanthydrol has also been used to
84
derivatize acrylamide20 in processed foods such as potato chips.21,22 9-Xanthydrol reacts with
85
acetamide in aqueous solutions at mildly acidic conditions and forms xanthyl-acetamide, which
86
can be detected and quantitated using hot GC injection.
87
In this manuscript, we assess the suitability of 9-xanthydrol derivatization and direct GC/MS
88
injection to measure acetamide in food matrices, particularly milk and beef. The method was
89
compared to direct GC/MS injection without derivatization. We also performed experiments to
90
evaluate whether this protocol generates artifactual acetamide from N-acetylated compounds.
91
Using this method, we demonstrate the abundance of acetamide in milk and beef products
92
marketed in the United States.
93 94
MATERIALS AND METHODS:
95
Reagents and Stock Solutions
96
Acetamide, d3-acetamide, propionamide, 9-xanthydrol and methanol were purchased from
97
Sigma Aldrich (St. Louis, MO). Ethyl acetate and hexane were purchased from Fisher Chemicals
98
(Fair Lawn, NJ). Sodium chloride and acetone were purchased from Macron Fine Chemicals
99
(Center Valley, PA). Acetone was confirmed by GC/MS to be free of detectable acetamide. 5 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
100 101
Water was prepared using a Millipore MilliQ purification system and hydrochloric acid was purchased from EMD Millipore (Burlington, MA).
102
HCl solution (0.5 M) was prepared in methanol by adding 8.25 mL of HCl stock solution (12.1
103
M) to 191.75 mL methanol in a 200 mL volumetric flask. KOH solution (0.7 M) was prepared by
104
dissolving 0.39 g of KOH in 10 mL water. 9-Xanthydrol solution (5%) was prepared by
105
dissolving 2.5 g of 9-xanthydrol in 50 mL of methanol. Stock solutions of acetamide,
106
propionamide and d3-acetamide were prepared in methanol at 1 g/L by dissolving 10 mg of the
107
chemicals in 10 mL of methanol. Working solutions (10, 50 and 100 ppm) of each chemical were
108
prepared by dilution of 1 g/L stock solution accordingly.
109
Milk, Meat and Coffee Samples
110
Twenty-three pasteurized whole milk and 44 raw sirloin beef samples were purchased from
111
different grocery stores within the State of Michigan, USA. In addition, raw, unprocessed, milk
112
was collected from 14 individual cows, over a period of four weeks. Samples were stored in
113
centrifuge tubes in a freezer (below -20 ˚C) until analysis (within 2-3 d of collection).
114
Coffee samples were purchased from different stores in Michigan and were comprised of 18
115
different varieties of roasted coffee beans, 3 varieties of green (raw) coffee beans and 8 varieties
116
of instant coffee.
117
Preparation of Standards and Calibration Curves
118
Standards for calibration curves were prepared by spiking matrix (milk, coffee and beef) with
119
d3-acetamide as the surrogate analyte and propionamide as the internal standard. The surrogate
120
analyte d3-acetamide was used to account for the variable and non-zero presence of native
121
acetamide in food matrices. Neither d3-acetamide nor propionamide were detected in all
122
unspiked food matrices tested. For milk analysis, standards were prepared by spiking 9.0 mL 6 ACS Paragon Plus Environment
Page 6 of 37
Page 7 of 37
Journal of Agricultural and Food Chemistry
123
milk with 0.0, 0.1, 0.25, 0.5, 1.0, 2.5 and 5.0 µg/mL of d3-acetamide as surrogate analyte and 0.5
124
µg/mL of propionamide as internal standard. The spiked milk samples were processed and
125
derivatized as described below. Linear calibration curves based on equal weighting were then
126
prepared from responses of xanthyl-d3-acetamide (relative peak areas of xanthyl-d3-acetamide to
127
xanthyl-propionamide) on the spiked concentration of d3-acetamide. For beef analyses, standards
128
were prepared by spiking 5 g of raw beef with 0.0, 0.1, 0.25, 0.5, 1.0, 2.5 and 5.0 ppm of d3-
129
acetamide as surrogate analyte and 0.5 ppm of propionamide as internal standard. The spiked
130
beef samples were processed using the extraction and derivatization protocol.
131
For analysis of coffee samples, standards were prepared by spiking 9.0 mL of aqueous coffee
132
bean extract with 0.0, 0.1, 0.25, 0.5, 1.0, 2.5 and 5.0 µg/mL of d3-acetamide as surrogate analyte
133
and 0.5 µg/mL of propionamide as internal standard. The spiked coffee samples were processed
134
using the extraction and derivatization protocol.
135
Calibration curves were then prepared from dependence of responses of xanthyl-d3-acetamide
136
as the surrogate analyte (relative peak areas of xanthyl-d3-acetamide to xanthyl-propionamide)
137
on the spiked concentration of d3-acetamide.
138
approximately 0.64/ppm for milk, 0.59/ppm for beef, and 0.42/ppm for coffee, respectively.
139
Regression coefficients of the calibration curves were all greater than 0.98.
140
Derivatization Procedure
Slopes for the calibration curves were
141
A 9.0-mL aliquot of milk was spiked with internal standard (100 µL from a 50 ppm stock
142
solution of propionamide) and 900 µL of water was added to each milk sample in 15-mL
143
polypropylene centrifuge tubes. Tubes were centrifuged at 16420 ×g for 10 min and the fat layer
144
on top was removed. A 5-mL volume of the defatted milk was then transferred to a new 15 mL
145
tube and 5 mL of 0.5 M HCl solution was added to precipitate proteins. Tubes were centrifuged 7 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
146
as before, and 5 mL of the supernatant was transferred to new tubes, followed by addition of 200
147
µL of 9-xanthydrol solution in methanol (5%). Tubes were incubated at 40 ˚C for 1.5 h, after
148
which 2 mL of 0.7 M KOH solution, 3 g of NaCl and 3 mL of ethyl acetate were added in turn.
149
Tubes were vortexed and centrifuged, and 1.5 mL of the ethyl acetate phase was transferred to a
150
2 mL microcentrifuge tube. Ethyl acetate was evaporated to dryness using a SpeedVac and
151
analytes were dissolved in 150 µL of ethyl acetate. Microcentrifuge tubes were vortexed and
152
then centrifuged at 20817 ×g for 10 min. A 100 µL aliquot of the supernatant was transferred to
153
vials for GC/MS analysis.
154
Raw beef samples were ground, using a meat grinder, frozen by immersion in liquid nitrogen,
155
and processed using a Ninja blender. Five grams of the homogenized beef were placed in 50 mL
156
polypropylene centrifuge tubes, and 3 mL of water and 11.95 mL of methanol and 50 µL of 50
157
ppm propionamide solution were added to each tube. Samples were then shaken for 2 h at 50 ˚C.
158
After 2 h, tubes were centrifuged at 8045 ×g for 10 min. Supernatants were transferred to new
159
tubes, 15 mL of hexane were added to remove lipids. Tubes were vortexed and centrifuged and
160
hexane layers were removed, then placed in a -80 ˚C freezer overnight for protein precipitation.
161
Next day samples were thawed at room temperature, centrifuged and supernatant was used for
162
the derivatization. The supernatant (1.2 mL), 50 µL of 1 M HCl and 200 µL of 5% 9-xanthydrol
163
solution were then added to 2-mL microcentrifuge tubes and incubated at 40 ˚C for 2.5 h with
164
shaking. Solvents were evaporated from the tubes using a SpeedVac. An 800 µL volume of
165
saturated NaCl in water, 60 µL of 0.7 M KOH, and 800 µL of ethyl acetate were added in turn to
166
each tube. Tubes were vortexed for 3 min using a multitube vortexer. A 500 µL aliquot of the
167
ethyl acetate layer was transferred to a new tube and another 800 µL of ethyl acetate was added
168
to the original tube for a second extraction. This time 700 µL of the ethyl acetate was removed 8 ACS Paragon Plus Environment
Page 8 of 37
Page 9 of 37
Journal of Agricultural and Food Chemistry
169
and added to the initial 500 µL. Ethyl acetate then was evaporated using a SpeedVac system and
170
analytes were dissolved in 100 µL of ethyl acetate. Tubes were centrifuged and 60 µL of the
171
supernatant were transferred to GC/MS vials with glass inserts for GC/MS analysis.
172
Finely ground coffee bean samples (12 grams) were Soxhlet extracted with 250 mL of water
173
for 16 h. The resulting extract was used for the derivatization procedure. Instant coffee samples
174
(four of which were pre-portioned by the manufacturer) ranged from 4.0 - 6.6 grams and were
175
each dissolved in 250 mL of boiling water. The resulting matrix was used for the derivatization
176
procedure. A 9.0-mL aliquot of coffee was spiked with internal standard (100 µL from a 50 ppm
177
stock solution of propionamide) and 900 µL of water was added to each coffee sample in 15-mL
178
polypropylene centrifuge tubes. Tubes were centrifuged at 16420 ×g for 10 min. A 5-mL volume
179
of the coffee supernatant was then transferred to a new 15 mL tube and 5 mL of 0.5 M HCl
180
solution was added. Tubes were centrifuged as before, and 5 mL of the supernatant was
181
transferred to new tubes, followed by addition of 200 µL of 9-xanthydrol solution in methanol
182
(5%). Tubes were incubated at 40 ˚C for 1.5 h, after which 2 mL of 0.7 M KOH solution, 3 g of
183
NaCl and 3 mL of ethyl acetate were added in turn. Tubes were vortexed and centrifuged, and
184
1.5 mL of the ethyl acetate phase was transferred to a 2 mL microcentrifuge tube. Ethyl acetate
185
was evaporated to dryness using a SpeedVac and analytes were dissolved in 150 µL of ethyl
186
acetate. Microcentrifuge tubes were vortexed and then centrifuged at 20817 ×g for 10 min. A
187
100 µL aliquot of the supernatant was transferred to vials for GC/MS analysis.
188
GC/MS Method
189
GC/MS analyses were carried out using a 7890A GC system, equipped with 7683 autosampler,
190
interfaced to a 5973C single quadrupole mass spectrometer (Agilent, Santa Clara, CA). The
191
capillary column used for separation of xanthyl derivatives was a 30 m x 0.25 mm i.d., 0.25 µm 9 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
192
film VF5 with 10 m EZ guard (Agilent, Santa Clara, CA). The capillary column used for
193
quantitation of acetamide (no derivatization) was a 30 m x 0.25 mm i.d., 0.25 µm film DB-WAX
194
(Agilent, Santa Clara, CA). Helium was used as the carrier gas. For the 9-xanthydrol method the
195
flow rate was set at 1.2 mL/min. Injection volume was 1.0 µL using split mode (1:8) at 240 ˚C
196
with the following temperature profile: initial column temperature: 40 ˚C and hold for 2 min;
197
increase to 300 ˚C at 20 ˚C /min and hold for 15 min. The total run time was 40 min per sample.
198
The mass spectrometer was operated in electron ionization (EI) mode at 70 eV. The analytes
199
were detected using selected ion monitoring (SIM) mode for the molecular ions (m/z 239, 242
200
and 253 for xanthyl-acetamide, xanthyl-d3-acetamide and xanthyl-propionamide respectively).
201
The dwell time for each channel was 120 ms. For initial compound characterizations, the mass
202
spectrometer was operated in full scan mode (m/z 30-400).
203
For measurements of acetamide without derivatization, the carrier flow rate was set at 1.5
204
mL/min. Splitless injection of 1.0 µL was made at 240 ˚C with the following column temperature
205
profile: initial column temperature at 50 ˚C and hold for 1 min; increase to 250 ˚C at 15 ˚C /min
206
and hold for 2 min. The total run time was 16.3 min/ sample. The mass spectrometer was
207
operated in electron ionization (EI) mode at 70 eV. The analytes were detected using selected ion
208
monitoring (SIM) of molecular ions m/z 59 and 62 for acetamide and d3-acetamide respectively.
209
For initial compound characterization, the mass spectrometer was operated in full scan mode
210
(m/z 30-400) to generate full EI mass spectra.
211 212
RESULTS AND DISCUSSION
213
Artifactual Acetamide Formation During GC/MS
10 ACS Paragon Plus Environment
Page 10 of 37
Page 11 of 37
Journal of Agricultural and Food Chemistry
214
To evaluate artifactual formation of acetamide from N-acetylated compounds, we injected
215
solutions of selected N-acetylated compound standards (at various concentrations) directly into
216
the heated injector (240 ˚C) for GC/MS analysis. Compounds injected were N-
217
acetylglucosamine, sialic acid, N-acetylcysteine and two tri-saccharides; 3-sialyllactose (one of
218
the most abundant sugars in bovine milk and colostrum), and 6-sialyl-N-acetyllactosamine. As
219
anticipated, we detected acetamide in each of the samples, thereby demonstrating artifactual
220
formation of acetamide via thermal degradation. Illustrative data for N-acetylglucosamine are
221
shown in Figure 1. On a molar basis, approximately 15-20% of each precursor was converted to
222
acetamide. Based on these observations, we expect artifactual detection of acetamide when milk
223
or beef extracts are analyzed using direct-injection GC/MS because N-acetylated compounds
224
persist even after sample processing.
225
226
Approaches to Circumvent Artifacts in Acetamide Analysis
227
To minimize artifacts, we tried several approaches that proved to be unsuccessful:
228
We performed cool-on-column injection into the GC/MS to circumvent artifactual formation
229
of acetamide. In this technique, the milk extract was injected directly into the column at 50 ˚C
230
instead of 240 ˚C. Although this technique eliminated the breakdown of N-acetylated compounds
231
in the GC inlet, the method proved impractical because the acetamide peak became broader
232
following multiple injections of milk extract, and components in the milk acetone extract
233
plugged the column after only a few samples. We also evaluated a purge-and-trap technique, in
234
which acetamide is purged from the solution into the vapor phase using helium at up to 70 ˚C.
235
Acetamide was first adsorbed from the vapor phase onto a sorbent, and then thermally desorbed
236
onto the GC column. In principal, this technique could have avoided interference from N11 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
237
acetylated compounds due to their low vapor pressure, but the technique proved impractical due
238
to an unacceptably low purge efficiency (less than 5%) of acetamide.
239
Artifacts may be eliminated if acetamide is separated from other interfering compounds before
240
GC/MS analysis. We tested this approach using phenylboronic acid (PBA) resins to covalently
241
bind to sugars, which could remove N-acetylated sugars from the sample prior to GC/MS
242
injection. However, the high levels of lactose in milk overloaded the resin, making this approach
243
infeasible. A membrane nanofiltration technique to remove sugars was also not successful for the
244
same reason. Charcoal and other sorbents also failed to selectively adsorb the N-acetylated
245
sugars.
246
The most promising method to date exploited derivatizing acetamide using 9-xanthydrol, a
247
derivatizing reagent that was previously used for successful analysis of acrylamide in food
248
matrices21,
249
were less severe than for milk and beef. Our experiments, described below, showed that the 9-
250
xanthydrol derivatization method was successful for analyzing acetamide in milk and beef, two
251
matrices considered likely to present high concentrations of N-acetylated compounds. An
252
overview of the 9-xanthydrol derivatization reaction is shown in Figure 2.
22
and to detect acetamide in environmental water samples21 where matrix effects
253
Excess 9-xanthydrol is added to sample containing acetamide. Derivatization proceeds at 40 ˚C
254
at pH