Geophysical Monitoring of Hydrocarbon-Contaminated Soils Remediated with a Bioelectrochemical System Deqiang Mao, Lu Lu, Andre Revil, Yi Zuo, John Hinton, and Zhiyong Jason Ren Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.6b00535 • Publication Date (Web): 07 Jul 2016 Downloaded from http://pubs.acs.org on July 8, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 31
1 2
Environmental Science & Technology
Geophysical Monitoring of Hydrocarbon-Contaminated Soils Remediated with a Bioelectrochemical System
3 4
Deqiang Mao1, Lu Lu2, André Revil3*, Yi Zuo4, John Hinton1, and Zhiyong Jason Ren2
5 6
1
Colorado School of Mines, Department of Geophysics, Golden, 80401, CO, USA
7
2
Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, Boulder,
8
Colorado 80309, United States
9
3
ISTerre, CNRS, UMR CNRS 5275, Université de Savoie, 73376 cedex, Le Bourget du Lac, France
10
4
Chevron Energy Technology Company, San Ramon, California 94583, United States
11 12 13 14
* Corresponding Author: André Revil
15
Phone: 33+ (0)479758715
16
Emails:
[email protected] 17 18 19 20 21 22 23 24 25
1 ACS Paragon Plus Environment
Environmental Science & Technology
Page 2 of 31
26
Abstract. Efficient non-invasive techniques are desired for monitoring the remediation process
27
of contaminated soils. We applied the direct current resistivity technique to image conductivity
28
changes in sandbox experiments where two sandy and clayey soils were initially contaminated
29
with diesel hydrocarbon. The experiments were conducted over a 230 day period. The removal
30
of hydrocarbon was enhanced by a bioelectrochemical system (BES) and the electrical potentials
31
of the BES reactors were also monitored during the course of the experiment. We found that the
32
variation in electrical conductivity shown in the tomograms correlate well with diesel removal
33
from the sandy soil, but this is not the case with the clayey soil. The clayey soil is characterized
34
by a larger specific surface area and therefore a larger surface conductivity. In sandy soil, the
35
removal of the diesel and products from degradation leads to an increase in electrical
36
conductivity during the first 69 days. This is expected since diesel is electrically insulating. For
37
both soils, the activity of BES reactors is moderately imaged by the inverted conductivity
38
tomogram of the reactor. An increase in current production by electrochemically active bacteria
39
activity corresponds to an increase in conductivity of the reactor.
40
2 ACS Paragon Plus Environment
Page 3 of 31
41
Environmental Science & Technology
TOC Art
42
43 44 45 46 47 48 49 50 51 52 53 54 55 56
3 ACS Paragon Plus Environment
Environmental Science & Technology
57
Page 4 of 31
INTRODUCTION
58
Hydrocarbon contamination due to accidental spills and tank leakages represents a threat
59
to the environment1,2. Besides natural attenuation of the contaminants3,4, a number of engineering
60
solutions have been applied to enhance the remediation process5,6. Recently, bioelectrochemical
61
systems (BESs) were developed and tested for the remediation of hydrocarbon contaminated
62
soils7-13. During the remediation process, the BES provides an environment for electrochemically
63
active bacteria (EAB) to catalyze the oxidation of organic electron donors, e.g., hydrocarbon
64
contamination, and deliver the electrons to the anode. Produced electrons are collected on the
65
anode and transferred through an external circuit to the cathode, where O2 serves as the unlimited
66
terminal electron acceptor9,14. Previous studies showed BESs could enhance hydrocarbon
67
degradation by up to 241% in saturated soils12. In addition, no external energy is required by this
68
process and in fact a small current is even produced that can be used in turn to power small
69
electronic sensors for onsite monitoring.
70
Even though BESs have demonstrated improved performance in hydrocarbon-
71
contaminated soil remediation and provide current as a proxy for monitoring13, they still relies on
72
traditional total petroleum hydrocarbon (TPH) measurements, which are intrusive and time
73
consuming. The TPH measurement involves soil sampling, blending with volatile and toxic
74
chemicals, plus multiple stages of extractions using vortex and sonication. Another issue is that
75
the spatial coverage of TPH measurements is usually very limited. In order to provide more
76
accurate, real time, and easy remediation monitoring, new methods that are fast and non-
77
intrusive are urgently needed.
78
Electrical resistivity survey is a non-invasive geophysical method consisting in imaging
79
the electrical resistivity or electrical conductivity of porous media15. Electrical conductivity is 4 ACS Paragon Plus Environment
Page 5 of 31
Environmental Science & Technology
80
sensitive to the salinity and temperature, water content, and cation exchange capacity (CEC) or
81
specific surface area (SSp) of soils16. During a resistivity survey, an electrical current is injected
82
through current electrodes, and at the same time, differences of electrical potentials are measured
83
at voltage electrodes17-19. Resistivity survey has been applied to track the movement of saline
84
plume20, 21 and contaminants22. For petroleum hydrocarbon contamination, a number of studies
85
have been done to show the potential of resistivity survey monitoring23-25. Several laboratory
86
experiments have been conducted on soil samples to understand the relation between electrical
87
conductivity and hydrocarbon contamination by manually mixing different contents of
88
hydrocarbon products with uncontaminated soil26-28. For non-wetting oils, e.g. diesel29, the
89
measured conductivity is well correlated with hydrocarbon content, with a lower content
90
corresponding to a higher conductivity. This is true for both fresh oil and biodegraded oil taken
91
from field sites28.
92
In the current study, diesel is chosen as the hydrocarbon contaminant and mixed with
93
either sandy or clayey soil in two tanks for characterizing the BES reactor efficiency in
94
accelerating hydrocarbon degradation. When non-conductive diesel is consumed by degradation
95
and removed from soils, it is expected to increase the electrical conductivity of the material. A
96
time lapse resistivity survey is designed to capture these changes during the tank experiment.
97
Our goal is to establish the relationship between the diesel TPH content and measured electrical
98
conductivity variations. At the same time, besides the monitoring of voltage generation from
99
BES reactors, reactors were also evaluated in the resistivity survey in terms of conductivity
100
variation.
101 102
MATERIALS AND METHODS
5 ACS Paragon Plus Environment
Environmental Science & Technology
Page 6 of 31
103
Tank Setup. The two tanks used for the analysis had a dimension of 40 cm × 5.5 cm ×
104
20 cm (Figure 1). The BES reactor was placed on the left side of each tank. A column-type BES
105
reactor was characterized by an outer diameter of 4.5 cm. A total of 32 stainless steel electrodes
106
were fixed to the side wall of the tank. These electrodes were connected with a banana socket
107
panel for resistivity surveys. Two sites at x = 5 cm and x = 39 cm which were 1 cm and 35 cm
108
away from the reactor were used as soil sampling locations for TPH measurements. Three
109
locations A, B and C, at x = 7 cm, 14 cm and 30 cm, were chosen as soil electrical conductivity
110
measurements at the end of the experiment. For each of the three locations, soil samples at three
111
different levels were taken.
112
Two different types of soils, sandy and clayey soils, at saturated conditions were
113
employed to test the effectiveness of the BES reactors. Two soils were prepared by mixing
114
natural soils with pure silica (Type 7030 from Unimin Corporation) sand or pure clay (Pottery
115
clay from Stone Leaf Pottery), respectively. Natural soil is needed for indigenous bacterial
116
population. The natural soil characteristics were reported by Lu et al. [2014]13. After mixing,
117
sandy soil (57.14% sand, 28.93% silt and 13.93% clay in dry weight) was characterized as sandy
118
loam and clayey soil (33.12% sand, 35.46% silt and 31.42% clay in dry weight) was
119
characterized as clay loam according to USDA soil texture classification. The porosity of sandy
120
soil is 0.41, and 0.50 for clayey soil. SSp of sandy soil was measured at 1.68 m2/g, and 4.07 m2/g
121
for clayey soil with 5-point BET method. The CEC values30 of sandy and clayey soils are
122
calculated as 0.56 meq/100g and 1.35 meq/100g by assuming two elementary charges per nm2.
123
Diesel was chosen to represent the hydrocarbon contaminants. Diesel was well mixed with soils
124
before putting into tanks. Soils were saturated with artificial groundwater. Artificial groundwater
6 ACS Paragon Plus Environment
Page 7 of 31
Environmental Science & Technology
125
refers to a solution of 4 mM Na+, 0.2 mM Ca2+, 0.1 mM Mg2+, 2.4 mM Cl-, 2 mM HCO3- , and
126
0.1 mM SO42- in deionized water (conductivity ≈ 0.05 S/m at 22oC, pH ≈ 8.2)31.
127
During the whole experiment and in order to minimize evaporation, both tanks were
128
covered with plastic wraps on the surface excluding the area where the reactors were located.
129
The hollow pipe of the reactor was left open for exposure with air, which provides the terminal
130
electron acceptor in the form of O2. The water loss due to evaporation and leakage to the
131
perforated BES reactors was approximately compensated by adding deionized (DI) water twice a
132
week to maintain saturation. The saturated condition was observed from the moisture condition
133
at the surface of each tank.
134
Bioelectrochemical Reactor Operation. For both reactors, carbon cloth with activated
135
carbon catalyst served as air cathode32-34. For the anode, a carbon felt anode was used. Cation
136
Exchange Membrane (CEM) was employed as a separator between cathode and anode. Both
137
reactors were wrapped around a perforated PVC pipe, and the height of the PVC pipe was 25 cm.
138
Detailed information about how to construct reactors can be found in Lu et al. [2014]13.
139
Continuous current generated from the remediation process was monitored and evaluated
140
by an external circuit with a resistor during the whole experiment period. A 1000 Ω external
141
resistor was utilized to start the experiment when a sustainable and relative large voltage
142
(>100mV) was observed in a few days after the start of the experiment35, and at 162nd days it
143
was replaced with a small resistor of 100 Ω to speed up the remediation process.
144
Control experiment of natural biodegration was run in separate containers which had the
145
dimension of 8 cm × 5 cm. There were no BES reactors and geophysical electrodes installed for
146
the control experiments, and therefore TPH variation only reflects the natural biodegration. We
7 ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 31
147
took TPH measurements from the control experiment at the same time as the active tank
148
experiment for comparison.
149
Soil Sampling. Soil samples were taken throughout the experiment at two distances away
150
(x = 5 cm and x = 39 cm) from the reactor (Figure 1) for TPH measurements36. At each location,
151
5 g of soil from the top, middle and bottom of the tank were sampled and then mixed for TPH
152
measurements. Seven TPH measurements at day 0, 8, 40, 60, 120, 150 and 200 were conducted
153
at each location during the whole experiment. The initial TPH values for sandy and clayey soil
154
were 6960 mg/kg and 6495 mg/kg, respectively.
155
At the end of the experiment, soil samples were taken at three different locations A, B,
156
and C (Figure 1) for electrical conductivity measurement, at each location, lower (z ≈ 1.5 cm~4
157
cm), middle (z ≈ 6.5 cm~9 cm) and upper (z ≈ 11.5 cm~14 cm) levels soil samples were taken.
158
At each location, the average conductivities from all three levels were compared with results
159
from the resistivity tomograms. Soils conductivity was measured in a 1:5 (w/v) soil: deionized
160
(DI) water mixture37. With this method, the initial electrical conductivities for sandy and clayey
161
soils were 558 µS/m and 1109 µS/m, respectively.
162
Soil Column Conductivity Measurements. Measured conductivity tomograms are
163
affected by both surface conductivity and pore fluid conductivity, and these two contributions
164
cannot be separated in a resistivity survey. Therefore besides the tank experiment, soil column
165
experiments were setup to separate the influence of surface conductivity and diesel TPH content
166
for the two different types of soils. A four-electrode configuration (two current electrodes and
167
two voltage electrodes) was adopted. The soil column had a diameter of 3 cm and a length of 11
168
cm. Two stainless steel plates were used as current electrodes at both ends of the column, and
169
Ag-AgCl potential electrodes were inserted in the middle of column with a spacing of 3 cm. The
8 ACS Paragon Plus Environment
Page 9 of 31
Environmental Science & Technology
170
soil samples were saturated in a vacuum chamber. All the measurements were performed with
171
ZEL-SIP04-V02 impedance meter38. The real part of the complex conductivity at 1Hz was
172
chosen to represent electrical conductivity during a resistivity survey for analysis.
173 174 175
According to Waxman and Smits39, electrical conductivity ߪ (in S/m) of the material at low frequency can be represented as ଵ
ߪ = ߪ௪ + ߪ௦ , ி
(1)
176
where F (dimensionless) is the formation factor related to the connected porosity of the soil by a
177
power law relationship known as Archie’s law, ߪ௪ is the pore water conductivity, and ߪ௦ is the
178
surface conductivity associated to electrical conduction in the electrical double layer coating the
179
surface of the grains30. This surface conductivity is controlled by the SSp or the CEC of the clays.
180
Six electrolytes were obtained by mixing DI water and pure NaCl at the following conductivity
181
(at 298 K) ߪ௪ =0.002 S/m, 0.02 S/m, 0.08 S/m, 0.2 S/m, 0.8 S/m and 2.0 S/m.
182
For the TPH values in the soils, four different ratios were tried, TPH=0.0 g/kg, 7.5 g/kg,
183
13 g/kg ad 32 g/kg, and 0.0 g/kg means no diesel was added to the soil. Diesel was added to soil
184
first and artificial groundwater was then added. With the added diesel, it took a longer time to
185
expel air from the mixture (approximately 3 hours in this study) compared with only water as
186
pore fluid (0.6 hour) in a vacuum chamber. Potential loss of diesel due to evaporation was not
187
accounted. In such a short measurement period, there was also no consideration of the natural
188
degradation of diesel contaminants on the electrical conductivity.
189
Resistance Data Collection and Inversion. Resistivity surveys were conducted eight
190
times throughout the experiment (Figure 2), at day 12, 26, 42, 69, 105, 135, 187 and 230, with a
191
two week interval at the beginning of the test and a 1.5 month interval at the end. For each
192
survey, 480 resistance measurements were taken to cover the whole tank with a multichannel
9 ACS Paragon Plus Environment
Environmental Science & Technology
Page 10 of 31
193
instrument ABEM LS and survey duration was 15 min. For the 480 measurements, current
194
electrode pairs AB were chosen as 14 horizontal pairs and 3 vertical pairs, i.e. AB=15 and 21, 2
195
and 7, 21 and 27, and 15 and 2. For each current injection pair AB, potential electrodes pairs
196
were chosen with skip one scheme18. For example, for AB=2 and 15, potentials electrode pairs
197
MN=3 and 5, 4 and 6, 5 and 7, and so on.
198
All the 480 measurements were used for inversion. For each tank, the resistances from all
199
eight surveys were inverted together with the active time constraint (ATC) technique40, 41. This
200
technique improves the time-lapse imaging especially when the survey data is corrupted with
201
strong noise. Due to the sensitivity difference of a resistivity survey with higher sensitivity close
202
to the electrode arrays19, we presented the results in terms of conductivity ratio, which better
203
shows the variations. The result from the first survey (at day 12) was treated as a reference. The
204
conductivity ratio between the other seven surveys and the first one was presented for discussion.
205
In this way, a conductivity ratio greater than 1.0 indicates an increase of electrical conductivity.
206
The inversion was performed with a three dimensional finite element code built in the
207
Comsol and Matlab environments41. Because of the smaller tank thickness in the y direction, we
208
assumed no conductivity variation in the y direction. Therefore the inversion results were
209
presented as two dimensional cross-tomograms.
210
211
RESULTS AND DISCUSSION
212
Voltage Generation. Figure 2 shows the voltage profile for the two tanks. Stable voltage
213
was generated in both tanks. At the beginning the electrical voltage has a rising limb due to
214
acclimation of indigenous microbial electrochemical community, and then the voltage reaches a
215
stable value. A longer delay period is observed in the clayey soil to reach the stable value due to 10 ACS Paragon Plus Environment
Page 11 of 31
Environmental Science & Technology
216
slower mass transfer rate compared with the sandy soil from the restrict passage of solutes in
217
clayey soils42. For both tanks, a stable voltage is reached at around 160 mV.
218
After 162-day experiment, a 100 Ω resistor was used to replace the 1000 Ω to allow
219
faster electron flow35. Both reactors show immediate voltage fluctuation in response to the
220
resistor change and then the voltage decreased gradually with time. The immediate surge is
221
caused by the reestablishment of the microbial activity with the smaller resistor.
222
TPH Removal. The results from both tank and control experiments are shown in Figure
223
2 (Y axis on the right). Corresponding to the initial increase of voltage, there is an increase of
224
TPH close to the reactor at x = 5 cm for both tanks. This is due to the establishment of EAB
225
activity with high adsorption of carbon felt anode attracting more diesel contaminants towards
226
the reactor.
227
Generally, TPH has larger removal rate closer to the reactor (x = 5 cm) and relatively
228
lower rate further away (x = 39 cm) 13. However, the difference between these two distances is
229
very small, especially for sandy soil. This proves the relatively large radius of influence under
230
sandy soil condition. A higher TPH removal rate close to the reactor compared to TPH further
231
away creates a diesel concentration gradient. This concentration gradient could drive diesel
232
contaminant to diffuse towards the reactors. Another driving force is the hydraulic gradient
233
created by the perforated BES reactors. The continuous leaking of liquid into the reactors and
234
compensation from the adding DI water on the surface also drives the movement of diesel
235
contaminant. Since sandy soil has a larger hydraulic conductivity which permits a fast movement,
236
the difference between TPH measurements at the two distances is smaller compared to the clayey
237
soil.
11 ACS Paragon Plus Environment
Environmental Science & Technology
Page 12 of 31
238
Sandy soil shows a higher removal rate than clayey soil based on the general trend. Both
239
BES experiments have higher TPH removal rate than control experiments, but less evident for
240
clayey soil. Clay soil at x = 39 cm is almost close to the control test. First two TPH
241
measurements before day 8 are indistinguishable with control experiment. From the
242
measurement at day 40, we start to see the difference. At day 60, the difference becomes clearer.
243
In the control experiment, for sandy soil, TPH decrease to 5200 mg/kg which corresponds to 25%
244
removal rate, and 5550 mg/kg for clayey soil with removal rate 15%. With BES reactor, sandy
245
soil has remove 41% and 35% TPH at x = 5 cm and at x = 39 cm respectively which are 64% and
246
40% higher than natural biodegration. As expected, even with BES reactor, the TPH removal
247
rate of clayey soil is not as good as sandy soil. At day 60, it only has 23% and 17% TPH
248
removed at the two distances which is slightly higher than the control test value 15%, only 53%
249
and 13% increase from the control experiments. At the end of the experiments, sandy soil has
250
TPH values of 4100 mg/kg and 4210 mg/kg at x = 5 cm and 39 cm, which correspond to 41%
251
and 39% removal rates based on the initial TPH content. For the control test, it has a removal
252
rate 34%. For clayey soil, they are 4061 mg/kg at x = 5 cm and 4861 mg/kg at 39 cm which
253
correspond to 35% and 25% removal rates. As for the control test, it only removes 22% of the
254
TPH. From both tests, we can see that natural biodegration from the indigenous microorganisms
255
plays an important role during the TPH removal. Therefore, when analyzing the resistivity
256
change from the experiments, the change reflects the contribution from both BES and natural
257
biodegration.
258
Conductivity of Soil Column Measurements. The measured conductivity at 1Hz with
259
different salinities is shown in Figure3a obtaining the influence of surface conductivity. The
260
measured data was fitted with the relationship in Eq. (1). With this fitting, the obtained formation
12 ACS Paragon Plus Environment
Page 13 of 31
Environmental Science & Technology
261
factors are 4.4 and 2.9 for sandy and clayey soil respectively. Clayey soil indicates a larger
262
surface conductivity ߪ௦ = 0.051 S/m and sandy soil has a relatively smaller surface conductivity
263
ߪ௦ = 0.022 S/m. With both fluid conductivity and surface conductivity affect the surveyed
264
conductivity values, a larger surface conductivity corresponds to the higher clay content and also
265
indicates the smaller influence from the change of pore water conductivity, which makes
266
conductivity variation less evident when removing diesel from the soil.
267
In Figure3b, ߪ represents the electrical conductivity of soil sample without diesel
268
contaminant (0.0 g/kg). Both sandy and clayey soils have a decreasing conductivity trend with an
269
increasing TPH content as indicated in Figure3b. However, clayey soil shows a smaller decrease
270
trend with only a 5% drop at 32 g/kg TPH due to a larger surface conductivity. Conductivity of
271
sandy soil drops by 6% even at 7.2 g/kg TPH, and 22% drop when TPH reaches 32 g/kg.
272
Conductivity Ratio Tomograms. Figure 4 is the conductivity ratio tomograms for both
273
tanks where the sub titles show the survey day after the start of the experiment (12 being the
274
reference). For the analysis of the soil conductivity variation, we exclude the reactor region
275
marked by the dashed rectangles in black, and the conductivity variation of the reactors will be
276
evaluated separately. Since we didn’t have a parallel tank experiment to monitor the change of
277
conductivity with diesel removal under natural biodegration, the observed electrical conductivity
278
variation represents the contribution from both natural and enhanced biodegradations from BES
279
reactors.
280
Compared to clayey soil results in Figure 4b, there is a distinct variation trend for
281
saturated sandy soil (Figure 4a), which indicates the removal of TPH from the tanks. In Figure 4a,
282
in the region closer to the surface, we observed a continuous drop of conductivity indicated by
283
the blue color. There are two reasons for this drop. There is a buoyance effect from the diesel
13 ACS Paragon Plus Environment
Environmental Science & Technology
Page 14 of 31
284
contaminants. Diesel has a density 0.832 kg/L and therefore has a tendency to move up above the
285
pore water phase. A few weeks after the start of the experiment, there was a visual existence of
286
diesel spots on the surface of the sandy tank. Another reason is due to added DI water on the
287
surface to keep the soil saturated. Even though the tank is covered with plastic wrap to minimize
288
evaporation, the tank is not completely sealed and water is still lost from the surface under
289
Colorado’s dry climate. DI water is added to the surface twice a week. The added DI water only
290
has a conductivity of 10-4 S/m and therefore this low conductive pore water reduces the
291
conductivity of the sandy soil. The added DI water is believed to be the main reason for the
292
observed decrease of conductivity on the top layer of the soil.
293
From the tomograms, in the region below the surface, there is an increase of electrical
294
conductivity at first, which is then followed by a decrease trend. However, the variation is not
295
uniformly distributed inside the tanks. This is potentially from the uneven distribution of diesel
296
contaminants inside the tank. In some regions, there is an increase of conductivity by 30% (Day
297
69 in Figure4a) even with only 3 g/kg TPH removal, from approximately 7g/kg to 4g/kg (see
298
Figure2a the second and fourth TPH measurements). This is a much bigger variation than the
299
conductivity measurements shown in Figure 3b. There may exist some higher diesel content
300
spots in the tank, and the organic acids and bicarbonate accumulation from the degradation also
301
contribute to the increase of conductivity which is not accounted in the soil column
302
measurements. As discussed by Allen et al. [2007]43, an increase of culturable hydrocarbon-
303
degrading microbes is often observed in petroleum-contaminated sites. The presence of certain
304
bacterial phyla corresponds to an increase of conductivity. Microbial activity increase from BES
305
and natural biodegration can alter the subsurface electrolytic and interfacial properties of porous
306
media. This alternation can influence the electrical conductivity25, 44.
14 ACS Paragon Plus Environment
Page 15 of 31
Environmental Science & Technology
307
For the clayey soil, there was less variation in the conductivity ratio tomograms (Figure
308
4b). We also observed some diesel spots on the surface of the tank after a few weeks of operation.
309
However, the conductivity decrease trend close to the surface is not as clear as the sandy tank.
310
The DI water moves slower in the clayey soil due to the low hydraulic conductivity, and
311
therefore does not lead to a significant decrease to conductivity as indicated in the sandy soil (see
312
Figure 4a).
313
There is a significant increase of conductivity close to the reactor at 10 cm at the late
314
stage of the experiment. This happens after the change of smaller resistor (162 day) with a
315
concomitant reactor activity speedup. This increase is related to more consumption of diesel
316
contaminants close to the reactor.
317
Average Conductivity and TPH Variations. Because of the heavy soil sampling
318
activity at the two locations x = 5 cm and 39 cm (Figure1), the soil was highly disturbed in these
319
two regions. Therefore, we only consider the area inside the white dashed rectangle for
320
calculation of average conductivity variation (the area is indicated by white dashed rectangles in
321
the Figure 4a and Figure 4b Day 26). Solid lines in Figure 5a and 5b show the average
322
conductivity ratio variation for both tanks for the area inside the white dashed rectangles
323
indicated in Figure 4 (The last survey at 230 days is not used since it is beyond the last TPH
324
measurement). Figure 5a and 5b also have the average TPH ratio from the two locations (x = 5
325
cm and 39 cm) in dashed lines. The average TPH is calculated by taking the average of the TPH
326
measurements at the two locations to represent the TPH variation inside the tank. Since the
327
conductivity survey and TPH measurements are not taken at the same time, the average TPH
328
values at the same time of the conductivity survey are linearly interpolated. All TPH ratios are
329
referred to the interpolated TPH value at 12th day when the first conductivity survey taken.
15 ACS Paragon Plus Environment
Environmental Science & Technology
Page 16 of 31
330
As shown by the average conductivity, the conductivity increases first and then
331
decreases. The average conductivity ratio increases by about 12% at the fourth survey 69 days
332
after the start of the experiment and then slowly decreases by 5% at the seventh survey (187 days)
333
compared to the initial state. For the average TPH ratio result of sandy soil, there is a significant
334
drop for the first three results in Figure5a, and then followed by a slight increase and decrease
335
variation trend. The TPH decrease trend of the first three points corresponds to an increase of
336
average conductivity. This is consistent with previous research conclusions that a lower TPH will
337
reflect a higher conductivity value26-29.
338
After the first three data points in Figure 5a, we could not find this relation anymore
339
because there is another reason responsible for the observed variation of average electrical
340
conductivity. Indeed, there are two processes occurring at the same time during remediation
341
causing the change of electrical conductivity: (i) the removal of diesel contaminants and (ii) the
342
leakage of the pore fluid into the reactor. Nonconductive diesel is removed from soil through
343
biodegration and leads to organic acids and bicarbonate accumulation. This leads to the increase
344
of soil conductivity. At the same time, because the whole reactor is wrapped around a perforated
345
PVC pipe to maximize the cathode contact with air, pore fluid leaks through the perforated pipe
346
and creates a hydraulic gradient towards the reactor which is enhanced by the added DI water on
347
the surface. As a result of this head gradient, the removal of fluid and icons loss in the fluid from
348
the tank decrease conductivity of the soils. The saturation maintained by adding low conductive
349
DI water on the surface of the tanks could not compensate the decrease of conductivity.
350
The effect of leakage enhances both water flow and solute transport in this experiment.
351
Compared to solute transport under natural hydraulic gradient, e.g. 1%, which only moves a few
352
meters per year45, BES reactor itself creates a favorite situation for the transport of contamination.
16 ACS Paragon Plus Environment
Page 17 of 31
Environmental Science & Technology
353
In the tank experiment, if we assume the water table is approximately on the soil surface, and it
354
decrease to about 5 cm below the surface where it starts the perforated part of the PVC pipe. The
355
average hydraulic gradient can be calculated
356
as infiltration as what naturally happens from predipitation23, and the sandy soil example shows
357
us that it can help the movement of solute, and therefore it will help the remediation process46.
ଷହିସ.ହ ହ
≈14%. The act of adding water can be treated
358
For the sandy soil, the conductivity trend confirms that higher TPH removal rate is more
359
prevailing than the leakage of fluid at early period. At later period, the TPH removal rate slows
360
down as shown by the TPH variation. The decrease of conductivity from leakage is more
361
dominant which causes the decrease of surveyed conductivity. The smaller surface conductivity
362
for the sandy soil (ߪ௦ =0.022S/m) supports more influence of pore water in this study.
363
For the clayey soil in Figure 5b, we only observed a decrease trend in conductivity,
364
reaching 10% at 187th days with respect to the reference. The TPH ratio also continues dropping
365
throughout the experiment. The removal of diesel does not lead to an increase of conductivity at
366
the beginning of experiment compared to the results in Figure 5a for the sandy soil. As
367
confirmed by soil column results, this is due to the large surface conductivity of the clayey soil
368
(ߪ௦ = 0.051 S/m). Leakage of fluid is more important for conductivity variation throughout the
369
whole experiment. The removal of fluid decreases fluid conductivity, and therefore what is
370
shown in Figure 4a is a steady decrease.
371
Lateral Conductivity Variations. At the end of the experiment, we took soil samples
372
from the three locations A, B, and C (Figure 1) to evaluate the spatial variation away from
373
reactors. The conductivity ratio from the last survey at these three locations was also extracted
374
from the inverted tomograms. The extracted areas are indicated by three solid white rectangles in
375
Figure 4. Figure 5c is the comparison between sampled conductivity ratios and inverted values at
17 ACS Paragon Plus Environment
Environmental Science & Technology
Page 18 of 31
376
8th survey from the two tanks. In Figure 5c, from both soil samples, there is a decrease trend
377
away from the reactor at locations A to C, indicating the loss of ions during the leakage process
378
throughout the duration of the experiment and its influence at the later period of the experiment.
379
This is supported by the tomograms of sandy soil figure4a. The increase of conductivity closer to
380
the reactor (indicated by red color) is always higher than the value further away, especially in the
381
last tomogram at Day 230.
382
The cross plot between inversion results and measured conductivity values shows a linear
383
relationship which means the geophysical survey can capture the conductivity variation in the
384
lateral direction. The relationship is not 1:1. The first reason is because of the uneven diesel
385
distribution in the tank initially, and there is only one initial value taken from each tank. When
386
taking the ratio with respect to the initial condition for all the samples, it introduces some
387
uncertainty. For the numerical inversion results, the ratio is taken with respect to the conductivity
388
in A, B, and C locations from the first survey at 12th day respectively. Another reason is the way
389
we measured electrical conductivity by drying the soil first and then mixing with DI water with
390
1:5 ratio37. With this method, the measured conductivity from soil samples can only be used
391
relatively compared to the in situ measurements from resistivity surveys.
392
Relationship between Electrical Conductivity and Voltage in BES Reactors. There is
393
no soil existing in the region of reactors with a hollow pipe design. Therefore, the reactor
394
conductivity variations reflect the activity on the anode of the reactor itself rather than bulk
395
conductivity of the soil. We analyzed conductivity variation of both reactors separately. During
396
the experiment, we also observed a conductivity variation for the reactors from the inversion
397
results. As shown in Figure 4a, the conductivity ratio for the reactor was closer to 1.0 first, and
398
then became smaller to 0.4 in blue color for the 6th survey Day 135. It then kept at the same
18 ACS Paragon Plus Environment
Page 19 of 31
Environmental Science & Technology
399
range. If we see the voltage curve in Figure 2a, the first survey on the 12th day was taken when
400
its magnitude reaches the peak, and is then followed by a gradual decrease. The conductivity
401
ratio and voltage ratio from the reactors are plotted in Figure 5d. For the voltage ratio, the
402
magnitudes 316 mV and 83 mV for sandy and clayey soils at day 12 was utilized as a reference.
403
As indicated by Figure 5d, it follows a moderate linear trend with a scattered pattern for
404
the clayey soil. The linear trend supports that a higher voltage corresponds to a more conductive
405
reactor in the inverted tomograms. The mechanism behind this linear trend can be related to the
406
activity of EAB. When the voltage of the BES reactor is high, that means the EAB activity is
407
high. More diesel contaminants are consumed, and therefore more electrons are produced. This
408
leads to the creation of a conductive anomaly during the resistivity survey.
409
We have demonstrated a useful non-invasive monitoring technique for diesel removal in
410
a tank experiment using resistivity survey. An increase of conductivity corresponds to a decrease
411
of TPH content in sandy soil at the early period of the experiment, but not for clay soil due to the
412
high surface conductivity, and these tank results are further supported by separate soil column
413
measurements with different TPH contents. The leakage of the fluid through the perforated BES
414
reactors causes a decrease of conductivity temporally indicated by the inverted conductivity
415
tomograms and spatially supported by the soil samples at the end of the experiment, and fluid
416
leakage also acts as a driving force for the movement of diesel contaminant towards the reactors.
417
Besides the traditional voltage monitoring of BES reactors, the activity of the BES reactors is
418
characterized by the magnitude of the conductivity in the inverted tomograms as well. A more
419
active BES reactor corresponds to an increase of conductivity in the conductivity tomograms.
420
Even though these results are only from a lab scale tank experiment, the encouraging results
421
support the usage of geophysical survey during contamination remediation monitoring. Further
19 ACS Paragon Plus Environment
Environmental Science & Technology
Page 20 of 31
422
large scale field tests are still needed to evaluate this technique under more complicated
423
environment to understand more influence parameters of electrical conductivity.
424 425 426
ACKNOWLEDGEMENTS
427
This work is funded by the Office of Science (BER), US. Department of Energy (awards DE-
428
SC0007118) and Chevron Energy Technology Company (grants CW852844 and K26625). We
429
also thank the specific surface area measurement from Dr. Ryan Richards’ lab of Colorado
430
School of Mines.
431
20 ACS Paragon Plus Environment
Page 21 of 31
Environmental Science & Technology
432
REFERENCES
433
1. Smith, S. E.; Hult, M. F. Hydrogeologic data collected from a crude-oil spill site near Bemidji,
434
Minnesota, 1983-91. 93-496,1993, https://pubs.er.usgs.gov/publication/ofr93496.
435
2. U.S. Environmental Protection Agency, Leaking Underground Storage Tank (LUST) Trust
436
Fund, 2014, http://www.epa.gov/oust/ltffacts.htm.
437
3. Cozzarelli, I. M.; Bekins, B. A.; Baedecker, M. J.; Aiken, G. R.; Eganhouse, R. P.; Tuccillo,
438
M. E., Progression of natural attenuation processes at a crude-oil spill site: I. Geochemical
439
evolution of the plume. J. Contam. Hydrol. 2001, 53, (3–4), 369-385.
440
4. Bekins, B. A.; Cozzarelli, I. M.; Godsy, E. M.; Warren, E.; Essaid, H. I.; Tuccillo, M. E.,
441
Progression of natural attenuation processes at a crude oil spill site: II. Controls on spatial
442
distribution of microbial populations. J. Contam. Hydrol. 2001, 53, (3–4), 387-406.
443
5. Riser-Roberts, E., Remediation of petroleum contaminated soils: biological, physical, and
444
chemical processes. CRC press: Lewis Publishers, NY, 1998.
445
6. Wang, H.; Luo, H.; Fallgren, P. H.; Jin, S.; Ren, Z. J., Bioelectrochemical system platform for
446
sustainable environmental remediation and energy generation. Biotechnol. Adv. 2015, 33, (3–4),
447
317-334.
448
7. Morris, J. M.; Jin, S.; Crimi, B.; Pruden, A., Microbial fuel cell in enhancing anaerobic
449
biodegradation of diesel. Chem. Eng. J. 2009, 146, (2), 161-167.
450
8. Zhang, T.; Gannon, S. M.; Nevin, K. P.; Franks, A. E.; Lovley, D. R., Stimulating the
451
anaerobic degradation of aromatic hydrocarbons in contaminated sediments by providing an
452
electrode as the electron acceptor. Environ. Microbiol. 2010, 12, (4), 1011-1020.
21 ACS Paragon Plus Environment
Environmental Science & Technology
Page 22 of 31
453
9. Wang, X.; Cai, Z.; Zhou, Q.; Zhang, Z.; Chen, C., Bioelectrochemical stimulation of
454
petroleum hydrocarbon degradation in saline soil using U-tube microbial fuel cells. Biotechnol.
455
Bioeng. 2012, 109, (2), 426-433.
456
10. Morris, J. M.; Jin, S., Feasibility of using microbial fuel cell technology for bioremediation
457
of hydrocarbons in groundwater. J. Environ. Sci.Health, Part A: Environ. Sci. Eng. 2008, 43, (1),
458
18-23.
459
11. Rakoczy, J.; Feisthauer, S.; Wasmund, K.; Bombach, P.; Neu, T. R.; Vogt, C.; Richnow, H.
460
H., Benzene and sulfide removal from groundwater treated in a microbial fuel cell. Biotechnol.
461
Bioeng. 2013, 110, (12), 3104-3113.
462
12. Lu, L.; Yazdi, H.; Jin, S.; Zuo, Y.; Fallgren, P. H.; Ren, Z. J., Enhanced bioremediation of
463
hydrocarbon-contaminated soil using pilot-scale bioelectrochemical systems. J. Hazard. Mater.
464
2014, 274, (0), 8-15.
465
13. Lu, L.; Huggins, T.; Jin, S.; Zuo, Y.; Ren, Z. J., Microbial Metabolism and Community
466
Structure in Response to Bioelectrochemically Enhanced Remediation of Petroleum
467
Hydrocarbon-Contaminated Soil. Environ. Sci. Technol. 2014, 48, (7), 4021-4029.
468
14. Wang, H.; Ren, Z. J., A comprehensive review of microbial electrochemical systems as a
469
platform technology. Biotechnol. Adv. 2013, 31, (8), 1796-1807.
470
15. Loke, M. H.; Chambers, J. E.; Rucker, D. F.; Kuras, O.; Wilkinson, P. B., Recent
471
developments in the direct-current geoelectrical imaging method. J. Appl. Geophys. 2013, 95,
472
135-156.
473
16. Revil, A.; Cathles, L. M.; Losh, S.; Nunn, J. A., Electrical conductivity in shaly sands with
474
geophysical applications. J. Geophys. Res. B: Solid Earth 1998, 103, (B10), 23925-23936.
22 ACS Paragon Plus Environment
Page 23 of 31
Environmental Science & Technology
475
17. Daily, W.; Ramirez, A., Electrical resistance tomography during in-situ trichloroethylene
476
remediation at the Savannah River Site. J. Appl. Geophys. 1995, 33, (4), 239-249.
477
18. Slater, L.; Binley, A. M.; Daily, W.; Johnson, R., Cross-hole electrical imaging of a
478
controlled saline tracer injection. J. Appl. Geophys. 2000, 44, (2–3), 85-102.
479
19. Kemna, A.; Kulessa, B.; Vereecken, H., Imaging and characterisation of subsurface solute
480
transport using electrical resistivity tomography (ERT) and equivalent transport models. J.
481
Hydrol. 2002, 267, (3–4), 125-146.
482
20. Singha, K.; Gorelick, S. M., Saline tracer visualized with three-dimensional electrical
483
resistivity tomography: Field-scale spatial moment analysis. Water Resour. Res. 2005, 41,
484
W05023.
485
21. Cassiani, G.; Bruno, V.; Villa, A.; Fusi, N.; Binley, A. M., A saline trace test monitored via
486
time-lapse surface electrical resistivity tomography. J. Appl. Geophys. 2006, 59, (3), 244-259.
487
22. Revil, A.; Skold, M.; Karaoulis, M.; Schmutz, M.; Hubbard, S. S.; Mehlhorn, T. L.; Watson,
488
D. B., Hydrogeophysical investigations of the former S-3 ponds contaminant plumes, Oak Ridge
489
Integrated Field Research Challenge site, Tennessee. Geophysics 2013, 78, (4), EN29-EN41.
490
23. Sauck, W. A., A model for the resistivity structure of LNAPL plumes and their environs in
491
sandy sediments. J. Appl. Geophys. 2000, 44, (2–3), 151-165.
492
24. Atekwana, E.; Werkema, D.; Duris, J.; Rossbach, S.; Atekwana, E.; Sauck, W.; Cassidy, D.;
493
Means, J.; Legall, F., In‐situ apparent conductivity measurements and microbial population
494
distribution at a hydrocarbon‐contaminated site. Geophysics 2004, 69, (1), 56-63.
495
25. Atekwana, E. A.; Atekwana, E.; Legall, F. D.; Krishnamurthy, R. V., Biodegradation and
496
mineral weathering controls on bulk electrical conductivity in a shallow hydrocarbon
497
contaminated aquifer. J. Contam. Hydrol. 2005, 80, (3–4), 149-167.
23 ACS Paragon Plus Environment
Environmental Science & Technology
Page 24 of 31
498
26. Schmutz, M.; Revil, A.; Vaudelet, P.; Batzle, M.; Viñao, P. F.; Werkema, D. D., Influence of
499
oil saturation upon spectral induced polarization of oil-bearing sands. Geophys. J. Int. 2010, 183,
500
(1), 211-224.
501
27. Revil, A.; Schmutz, M.; Batzle, M., Influence of oil wettability upon spectral induced
502
polarization of oil-bearing sands. Geophysics 2011, 76, (5), A31-A36.
503
28. Abdel Aal, G. Z.; Atekwana, E. A., Spectral induced polarization (SIP) response of
504
biodegraded oil in porous media. Geophys. J. Int. 2014, 196, (2), 804-817.
505
29. Schwartz, N.; Huisman, J. A.; Furman, A., The effect of NAPL on the electrical properties of
506
unsaturated porous media. Geophys. J. Int. 2012, 188, (3), 1007-1011.
507
30. Revil, A., Spectral induced polarization of shaly sands: Influence of the electrical double
508
layer. Water Resour. Res. 2012, 48, (2), W02517.
509
31. Hort, R. D.; Revil, A.; Munakata-Marr, J.; Mao, D., Evaluating the potential for quantitative
510
monitoring of in situ chemical oxidation of aqueous-phase TCE using in-phase and quadrature
511
electrical conductivity. Water Resour. Res. 2015, 51, (7), 5239-5259.
512
32. Yazdi, H.; Alzate-Gaviria, L.; Ren, Z. J., Pluggable microbial fuel cell stacks for septic
513
wastewater treatment and electricity production. Bioresource Technol. 2015, 180, 258-263.
514
33. Haeger, A.; Forrestal, C.; Xu, P.; Ren, Z. J., High performance spiral wound microbial fuel
515
cell with hydraulic characterization. Bioresource Technol. 2014, 174, 287-293.
516
34. Zhang, F.; Cheng, S.; Pant, D.; Bogaert, G. V.; Logan, B. E., Power generation using an
517
activated carbon and metal mesh cathode in a microbial fuel cell. Electrochem. Commun. 2009,
518
11, (11), 2177-2179.
24 ACS Paragon Plus Environment
Page 25 of 31
Environmental Science & Technology
519
35. Menicucci, J.; Beyenal, H.; Marsili, E.; Veluchamy; Demir, G.; Lewandowski, Z., Procedure
520
for Determining Maximum Sustainable Power Generated by Microbial Fuel Cells. Environ. Sci.
521
Technol. 2006, 40, (3), 1062-1068.
522
36. U.S. Environmental Protection Agency, Non-Halogenated Organics usingGC/FID, Method
523
8015D. In June 2003.
524
37. Kettler, T.; Doran, J. W.; Gilbert, T., Simplified method for soil particle-size determination
525
to accompany soil-quality analyses. Soil Sci. Soc. Am. J. 2001, 65, (3), 849-852.
526
38. Zimmermann, E.; Kemna, A.; Berwix, J.; Glaas, W.; Münch, H. M.; Huisman, J. A., A high-
527
accuracy impedance spectrometer for measuring sediments with low polarizability. Meas. Sci.
528
Technol. 2008, 19, (10), 105603.
529
39. Waxman, M. H.; Smits, L. J. M., Electrical Conductivities in Oil-Bearing Shaly Sands. Soc.
530
Petr. Eng. J. 1968, 8, (2), 107-122.
531
40. Karaoulis, M. C.; Kim, J. H.; Tsourlos, P. I., 4D active time constrained resistivity inversion.
532
J. Appl. Geophys. 2011, 73, (1), 25-34.
533
41. Mao, D.; Revil, A.; Hort, R. D.; Munakata-Marr, J.; Atekwana, E. A.; Kulessa, B.,
534
Resistivity and self-potential tomography applied to groundwater remediation and contaminant
535
plumes: Sandbox and field experiments. J. Hydrol. 2015, 530, 1-14.
536
42. Malusis, M. A.; Shackelford, C. D.; Olsen, H. W., Flow and transport through clay
537
membrane barriers. Eng. Geol. 2003, 70, (3–4), 235-248.
538
43. Allen, J. P.; Atekwana, E. A.; Atekwana, E. A.; Duris, J. W.; Werkema, D. D.; Rossbach, S.,
539
The Microbial Community Structure in Petroleum-Contaminated Sediments Corresponds to
540
Geophysical Signatures. Appl. Environ. Microb. 2007, 73, (9), 2860-2870.
25 ACS Paragon Plus Environment
Environmental Science & Technology
Page 26 of 31
541
44. Williams, K. H.; Ntarlagiannis, D.; Slater, L. D.; Dohnalkova, A.; Hubbard, S. S.; Banfield, J.
542
F., Geophysical Imaging of Stimulated Microbial Biomineralization. Environ. Sci. Technol. 2005,
543
39, (19), 7592-7600.
544
45. Panday, S.; Wu, Y. S.; Huyakorn, P. S.; Springer, E. P., A three-dimensional multiphase flow
545
model for assessing NAPL contamination in porous and fractured media, 2. Porous medium
546
simulation examples. J. Contam. Hydrol. 1994, 16, (2), 131-156.
547
46. Li, X.; Wang, X.; Ren, Z. J.; Zhang, Y.; Li, N.; Zhou, Q., Sand amendment enhances
548
bioelectrochemical remediation of petroleum hydrocarbon contaminated soil. Chemosphere 2015,
549
141, 62-70.
550
26 ACS Paragon Plus Environment
Page 27 of 31
Environmental Science & Technology
Figures
551
552
Reactor
Electrodes
TPH locations
EC location A
EC location B
EC location C
12 7
18
1 13
32 26
20
Z (cm)
8
27 3
35
21
) cm Y(
15 3 0
5
25 15
X (cm)
553
554 555 556 557 558
Figure 1. Tank configuration used for the experiment. Current from the BES reactor was monitored by a data acquisition system. A total of 32 resistance electrodes (black cubes) were attached on the side wall of the tank. Two sites (x = 5 cm and 39 cm, light blue) were used as TPH sampling locations during the whole experiment. Finally, 9 soil samples were taken from 3 locations A, B, and C at the end of experiments for electrical conductivity (EC) measurements.
559
27 ACS Paragon Plus Environment
Environmental Science & Technology
Page 28 of 31
560
561
a) Sandy soil sandbox experiment TPH-5 cm TPH-39 cm Control
300
8000
200 6000 100
0
0
50
100
150
200
TPH (mg/kg)
Voltage(mV)
400
4000
Time(day)
b) Clayey soil sandbox experiment
8000
TPH-5 cm TPH-39 cm
300
Control
200 6000 100
0
0
50
100
150
200
TPH (mg/kg)
Voltage(mV)
400
4000
562
Time(day)
563
Figure 2. Time-series of the voltage generation of BES reactors and TPH degradation during the experiment. a) Sandy soil. b) Clayey soil. Eight resistivity surveys were conducted at day 12, 26, 42, 69, 105, 135, 187 and 230. They are indicated the inverted filled triangles. TPH variation measured for each tank and the results are referred to the Y axis on the right-side of the plot. Seven TPH measurements were taken at day 0, 8, 40, 60, 120, 150 and 200. Control experiments of the two soils were prepared in different containers without BES reactors. It represents the natural biodegration. The vertical solid lines at day 162 indicate the change of resistor from 1000Ω to 100Ω.
564 565 566 567 568 569 570
28 ACS Paragon Plus Environment
Page 29 of 31
Environmental Science & Technology
a) Conductivity data at saturation Conductivity of the soil (S/m)
0.60 0.40 0.20
Sandy soil Clayey soil
0.05
0.01 -3 10
Conductivity ratio (unitless)
574 575 576 577 578 579 580 581
100
Clayey soil 0.95
0.90
0.85
Sandy soil 0.80 0
573
10-1
b) Conductivity ratio vesus TPH
1.00
571 572
10-2
Pore water conductivity (S/m)
10
20
30
TPH (g/kg)
Figure 3: Petrophysical measurements. a) The solid dots show the electrical conductivity at 1Hz with different salinities for sandy and clayey soils. The data were fitted by a linear conductivity equation given by Eq. (1) of the main text. The fit of the data with this equation is materialized by the solid lines. Clayey soil has a bigger surface conductivity (ߪ௦ = 0.051 S m-1) than sandy soil (ߪ௦ = 0.022 S m-1). A bigger surface conductity will lower the influence of pore fluid conductivity created by diesel contaminants removal in this experiment. b) Electrical conductivity ratio σ / ߪ decreases with increasing TPH. ߪ denotes the soil conductivity with no diesel added in the soil sample.Sandy soil has a larger decrease rate than clayey soil due to a smaller surface conductivity as indicated the in Figure 3a.
582 29 ACS Paragon Plus Environment
Environmental Science & Technology
Page 30 of 31
583
a) Sandy soil sandbox tomograms Day 42
R E A 10 C T 5 O R
Z (cm)
Day 69
R E A C T O R
15
R E A C T O R
Day 105
Z (m)
Day 26
R E A C T O R
0
Day 187
Z (cm)
0
Day 230
Z (m)
R E A C T O R
R E A C T O R
Conductivity ratio Z (m)
Day 135 R E A 10 C T 5 O R 15
0
0
0.3
0.2
0.5
0.7
0.9
1.1
1.2
1.4
x
5
10
15
20
X (cm)
25
30
35
b) Clayey soil sandbox tomograms Day 42
Z (cm)
Day 69
R E A C T O R
R E A C T O R
Day 105
Z (m)
Day 26 R E A 10 C T 5 O R 15
R E A C T O R
0
Z (cm)
0
584
585 586 587 588 589 590 591 592 593
Day 230 R E A C T O R
Conductivity ratio Z (m)
Day 187 R E A C T O R
Z (m)
Day 135 R E A 10 C T 5 O R 15
0
0
0.2
0.3
0.5
0.7
0.9
1.1
1.2
1.4
x
5
10
15
20
X (cm)
25
30
35
Figure 4. Electrical conductivity ratio tomograms with respect to the first tomogram of electrical conductivity taken at day 12. a) Sandy soil. b) Clayey soil. Blue color (1.0) indicates the removal of diesel contaminants. Title of each subfigure denotes the measurement day after the start of the experiment. The dashed rectangle (on the left side) indicates the location of the reactor. The dashed rectangles in white in the first figure show the area used to determine the average electrical conductivity used in Figure 5a and 5b. The solid rectangles (last plot) are three soil sample locations A, B and C at the end of the test. The solid black lines are the locations of surface and borehole electrode shown in Figure 1.
594
30 ACS Paragon Plus Environment
Page 31 of 31
Environmental Science & Technology
595
596
c) Measured vesus inverted conductivity ratios
a) Conductivity and TPH ratio variations: sandy soil 1.2
1.05
Conductivity
0.8
TPH
0.95
TPH ratio
Conductivity ratio
0.9
0.7
0.85 10
40
70
100
130
160
Meausurements ratio
1.15
0.6 190
A
Sand
B C
0.9
A
Clay
B C
0.6
0.3 0.6
0.9
1.2
1.5
Inversion ratio
Time (day)
b) Conductivity and TPH ratio variations: clayey soil
d) Comparison between conductivity and voltage ratios
1.15
2.5
0.8
TPH 0.95
598 599 600 601 602 603 604 605 606 607 608
Sand Clay
1.5
1
0.5
0.85 10
597
0.7
Conductivity
Voltage ratio
2 1.05
TPH ratio
Conductivity ratio
0.9
40
70
100
130
160
0.6 190
0
0
0.5
Time (day)
1
1.5
2
2.5
Conductivity ratio
Figure 5. Electrical conductivity and TPH ratio variations for a) sandy soil and b) clayey soil. Electrical conductivity ratio is calculated from tomograms in the dashed white rectangle area in Figure 4 (except last survey at 230th day), and TPH ratio variation is averaged from the two TPH sampling locations at x = 5 cm and x = 39 cm. For sandy soil, an increase of conductivity corresponds to a decrease of TPH for the first three data points. c) Comparison of the measured conductivity ratio of the sandy and clayey soil samples (measured from tanks) versus the inverted conductivity ratio at the same locations A, B, and C from the inverted tomograms. This linear relation shows that the laboratory measurements are consistent with the tomogram data. d) Linear relationship between the inverted conductivity ratio and the measured voltage ratio for sandy soil (red dots) and clayey soil (green dots) for BES reactors indicated by the dashed rectangles in black in Figure 4.
609
31 ACS Paragon Plus Environment