Human Hair Keratin for Biocompatible Flexible and Transient

Nov 21, 2017 - School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798, Singapore. ‡S...
0 downloads 14 Views 1MB Size
Subscriber access provided by READING UNIV

Article

Human Hair Keratin for Biocompatible Flexible and Transient Electronic Devices Jieun Ko, Luong Thi Hieun Nguyen, Abhijith Surendran, Bee Yi Tan, Kee Woei Ng, and Wei Lin Leong ACS Appl. Mater. Interfaces, Just Accepted Manuscript • DOI: 10.1021/acsami.7b16330 • Publication Date (Web): 21 Nov 2017 Downloaded from http://pubs.acs.org on November 25, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

ACS Applied Materials & Interfaces is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 29 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Applied Materials & Interfaces

Human Hair Keratin for Biocompatible Flexible and Transient Electronic Devices

Jieun Ko †, Luong T. H. Nguyen ‡, Abhijith Surendran †, Bee Yi Tan ‡, Kee Woei Ng ‡§, Wei Lin Leong *†∥

† School of Electrical and Electronic Engineering, Nanyang Technological University, 50 Nanyang Avenue, Singapore 639798 ‡ School of Materials Science and Engineering, Nanyang Technological University, Singapore 639798 § Nanyang Environment & Water Research Institute (Environmental Chemistry and Materials Centre), Nanyang Technological University, Singapore 637141 ∥ School

of Chemical and Biomedical Engineering, Nanyang Technological University, 70

Nanyang Drive, Singapore 637459 Singapore Email: [email protected]

1 ACS Paragon Plus Environment

ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 29

ABSTRACT Biomaterials have been attracting attention as a useful building block for biocompatible and bioresorbable electronics due to its non-toxic property and solution processabillity. In this work, we report the integration of biocompatible keratin from human hair as dielectric layer for organic thin-film transistors (TFTs), with high performance, flexibility and transient property. The keratin dielectric layer exhibited a high capacitance value above 1.27 µF/cm2 at 20 Hz due to the formation of electrical double layer. Fully solution processable TFTs based on

p-channel

poly[4-(4,4-dihexadecyl-4H-cyclopenta[1,2-b:5,4-b]dithiophen-2-yl)-

alt[1,2,5]thiadiazolo[3,4-c]-pyridine] (PCDTPT) and keratin dielectric exhibited high electrical property with a saturation field-effect mobility of 0.35 cm2 V-1 s-1 at a low gate bias of -2 V. We also successfully demonstrate flexible TFTs which exhibited good mechanical flexibility and electrical stability under bending strain. An artificial electronic synaptic PCDTPT/keratin transistor was also realized and exhibited high-performance synaptic memory effects via simple operation of proton conduction in keratin. An added functionality of using keratin as a substrate was also presented, where similar PCDTPT TFTs with keratin dielectric were built on top of keratin substrate. Finally, we observed that our prepared devices can be degraded in ammonium hydroxide solution, establishing the feasibility of keratin layer as various components of transient electrical devices including as a substrate and dielectric layer.

Keywords: Keratin, High-capacitance, Gate Insulator, Transient electronics, Thin-Film transistors, Biocompatible

2 ACS Paragon Plus Environment

Page 3 of 29 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Applied Materials & Interfaces

1. INTRODUCTION The race against global climate change and electronic pollution can be eased substantially with the development of green electronic devices that are composed of naturally abundant materials or biomaterials for full recyclability.1-3 In addition, natural materials isolated from the native environment and repurposed into thin-films can serve to be useful in building a form of biocompatible electronics for applications such as sensors for food monitoring, noninvasive diagnostic systems to improve patient care as well as bioresorbable, transient electronics which completely disappears in a controlled fashion after fulfilling its duty, paving the way for electronics to be everywhere, including on the skin or even within our bodies.4-6 In particular, the solution processabilty of these biomaterials are well suited for flexible or organic electronic devices such as organic memory devices, chemical sensors, energy storage devices and organic thin-film transistors (TFTs) to achieve sustainable, low cost and large area production. One major advantage is that these biomaterials can be processed from environmentally friendly solvents (such as water and alcohol), which also allows facile deposition of the natural compounds atop the subsequent active layers with orthogonal solubility. Specifically, natural biopolymers can be leveraged as biodegradable dielectrics in organic TFTs, including gelatin,7-8 chitosan,9-11 albumin,12-15 and silk fibroin16-18. To also achieve high-performance organic TFTs which operate at low voltages, it is essential for the gate insulators to possess high capacitance values. Previous work has shown that improved capacitance/ dielectric constants of the gate insulator could enhance the field-effect mobility of the TFTs.19-20 Biopolymer with high densities of aromatic and polar groups can serve as high capacitance gate insulator for logic devices, serving as the foundation for more complex

3 ACS Paragon Plus Environment

ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 29

devices. The biopolymers typically showed high capacitance values, from ~nF/cm2 to ~µF/cm2 ranges (Table S1). Keratins are sulfur-containing fibrous structural proteins found in hair, wool, feathers and nails that have robust physical properties.21 In comparison to other animal sources, keratin from human hair (Figure 1a) has distinct advantages of having an abundant supply and a realistic source of autologous proteins for biocompatible electronic devices.22-23 In addition, soluble human hair keratins can be easily obtained through a concoction of reducing agents in acidic or alkaline conditions. The extracted human keratins are solution processable and have been fabricated into various forms of coatings,24-26 fibrous matrices,27 hydrogels,23 and sponges.28 However, up to now, most of the keratin research has focused on biological applications, such as porous scaffold for tissue engineering or substrates for in vitro studies. Here, we report for the first time, keratin from human hair as a high capacitance dielectric layer as well as a supporting substrate for organic TFTs. The keratin dielectric layer exhibited good solution-processability and high capacitance values above ~1.27 µF/cm2 at 20 Hz due to its high dipolar nature and hygroscopicity. We have successfully utilized the keratin dielectric layer as a gate insulator by fabricating organic thin-film transistors based on p-channel donor–acceptor copolymer, poly[4-(4,4-dihexadecyl-4H-cyclopenta[1,2-b:5,4-b]dithiophen2-yl)-alt[1,2,5]thiadiazolo[3,4-c]-pyridine] (PCDTPT). The PCDTPT/keratin TFTs exhibited good charge transport properties with a field-effect mobility of 0.35 cm2 V-1 s-1at a low gate voltage bias of -2 V. The flexible PCDTPT/keratin TFTs fabricated on a polymer substrate also maintained the electrical properties before and after bending at 20 mm bending radius. Additionally, an artificial electronic synaptic PCDTPT/keratin transistor was realized and exhibited high-performance synaptic memory effects via simple operation of mobile ion conduction in keratin dielectric. An added functionality of using keratin as a substrate was also demonstrated, where similar organic TFTs were built on top of keratin substrate. Finally, 4 ACS Paragon Plus Environment

Page 5 of 29 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Applied Materials & Interfaces

the transient nature or disintegrability of keratin layer was investigated with PCDTPT/keratin TFT on keratin substrate, where we observed that our prepared devices can be degraded in alkaline solution, further demonstrating their potential for biocompatible and bioresorbable electronics.

2. EXPERIMENTAL SECTION 2.1. Materials. Human hair was obtained from local hairdressers. Poly[4-(4,4-dihexadecyl4H-cyclopenta[1,2-b:5,4-b]dithiophen-2-yl)-alt[1,2,5]thiadiazolo[3,4-c]-pyridine] (PCDTPT) was purchased from 1-Material (CAS#1334407-47-4). Ammonium hydroxide solution in water (28-30%) was purchased from Fisher Scientific. 2.2. Extraction of Human Hair Keratin. The keratin used in this study is extracted from human hair through a reduction process, which breaks the disulphide bonds in the original hair structure. The resulting extracted keratin therefore consists predominantly of keratin monomers. Briefly, the extraction of keratin from human hair is described as follows. Human hair samples were first washed with soap to remove dirt and grime. After rinsing, the hair was soaked in ethanol and left to dry at room temperature in a fume hood. Delipidization of the hair, where all lipids present in the top layer of hair are removed, was subsequently conducted by soaking the dried hair into a mixture of chloroform and methanol (2:1). After the delipidization, the dried hair was cut to lengths of 1 to 2 mm with scissors. Keratin was then extracted by immersing the cut hair in a 0.125 M of sodium sulfide nonahydrate (Na2S·9H2O) (98+%, ACS reagent, ACROS Organics) aqueous solution at 40 °C for 4 h. Next, the mixture was filtered with filter papers to remove hair debris. The keratin solution was subsequently transferred to a cellulose tubing of 10 kDa molecular weight cut-off and exhaustively dialyzed against deionized water to remove the remaining sodium sulfide. The

5 ACS Paragon Plus Environment

ACS Applied Materials & Interfaces 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 29

dialyzed solution was then freeze-dried to obtain keratin powder and stored at -20 °C until use. For the keratin substrate, an enriched fraction of keratin intermediate filament proteins (KIFP) was utilized, following a separation protocol described previously.29 Briefly, keratinassociated proteins were first removed by incubating human hair in pH 9 Tris-HCl buffer containing 8 M urea, 200 mM dithiothreitol (DTT) and 25% ethanol at 50 °C for 72 hr. The KIFP fraction was then separated by incubating human hair residue in pH 8.5 Tris-HCl buffer containing 5 M urea, 2.6 M thiourea and 200 mM DTT for 24 hr at 50 °C. After dialysis against DI water, KIFP solution (20mg/mL) was cast on glass substrate and dried at room temperature for 2 days. The resultant keratin substrate thickness was approximately 5 µm. 2.3. TFT fabrication and electrical characterization. The PCDTPT/keratin TFT device was fabricated on the heavily doped p-type Si (100) wafer. The wafer was cleaned with acetone and isopropyl alcohol in an ultrasonic bath for 10 min each, and then dried with the nitrogen. The cleaned substrates undergo plasma treatment for 30 min. Keratin solution was prepared by dissolving the keratin powder in distilled water (keratin: distilled water = 1.5:8.5) and centrifuged at 10,000 rpm for 15 min. The keratin solution was spin coated on the wafer substrate at 2000 rpm for 30 sec followed by thermal annealing at 70 °C for 10 min. Semiconductor solution was prepared by dissolving 4 mg of PCDTPT in 1 ml chlorobenzene. The semiconductor film was coated on keratin dielectric layer at 1500 rpm for 60 sec under an argon atmosphere. The resultant films were then annealed at 200 °C for 10 min. Finally, the gold source and drain contacts (thickness of 100 nm) were evaporated through a shadow mask, thereby defining a channel length of 50 – 100 µm and width of 300 – 500 µm. Reference PCDTPT devices have a 200 nm thick thermally grown SiO2 layer only. For capacitor device, Al electrode (100 nm) was evaporated on keratin film coated on the heavily doped p-type Si (100) wafer by thermal evaporation. The flexible PCDTPT/keratin TFT was 6 ACS Paragon Plus Environment

Page 7 of 29 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Applied Materials & Interfaces

fabricated on polyarylate (PAR) film. Ag bottom gate electrode (100 nm) was first evaporated on PAR substrate and the same fabrication processes of PCDTPT and keratin are followed. Similar devices are also built on keratin substrates. The output and transfer characteristics of the transistors as well as current-voltage characteristics of the capacitor devices were measured under ambient and vacuum (