This is an open access article published under an ACS AuthorChoice License, which permits copying and redistribution of the article or any adaptations for non-commercial purposes.
Article Cite This: ACS Omega XXXX, XXX, XXX−XXX
http://pubs.acs.org/journal/acsodf
Hyaluronic Acid-Based Hybrid Hydrogel Microspheres with Enhanced Structural Stability and High Injectability Yun-Jeong Seong,† Guang Lin,‡ Byung Jun Kim,‡ Hyoun-Ee Kim,†,§ Sukwha Kim,*,‡ and Seol-Ha Jeong*,† †
Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Republic of Korea Department of Reconstructive and Plastic Surgery, Seoul National University Hospital, Seoul 03080, Republic of Korea § Biomedical Implant Convergence Research Center, Advanced Institutes of Convergence Technology, Suwon 16229, Republic of Korea Downloaded via 185.101.68.24 on August 13, 2019 at 00:36:37 (UTC). See https://pubs.acs.org/sharingguidelines for options on how to legitimately share published articles.
‡
S Supporting Information *
ABSTRACT: For hydrogel injection applications, it is important to improve the strength and biostability of the hydrogel as well as its injectability to pass easily through the needle. Making gel microspheres is one approach to achieve these improvements. Granulization of a bulk hydrogel is a common procedure used to form microsized particles; however, the nonuniform size and shape cause an uneven force during injection, damaging the surrounding tissue and causing pain to the patients. In this study, injectable hyaluronic acid (HA)-based hybrid hydrogel microspheres were fabricated using a water-in-oil emulsion process. The injectability was significantly enhanced because of the relatively uniform size and spherical shape of the hydrogel formulates. In addition, the biostability and mechanical strength were also increased owing to the increased crosslinking density compared with that of conventionally fabricated gel microparticles. This tendency was further improved after in situ calcium phosphate precipitation. Our findings demonstrate the great potential of HA-based hydrogel microspheres for various clinical demands requiring injectable biomaterials. to meet the demands for injectability.13,14 The particulated assemblies are usually designed depending on the location or depth of the tissue or the applications.15,16 In this case, the stiffness and size of the particulated hydrogels critically affect the injection force when they are applied to tissue in vivo.17 Hyaluronic acid (HA) hydrogels are remarkable biocompatible and biodegradable polymers that are particularly popular for injectable clinical applications.18−23 HA is a hydrophilic polysaccharide composed of D-glucuronic acid and N-acetylD-glucosamine, which is found in the extracellular matrix (ECM) and regulates biological functions for cell proliferation and migration.24−26 Various chemical reactions have been used to modify HA hydrogel to control their mechanical properties, including their elasticity and degradation resistance.27 More-
1. INTRODUCTION Biomaterials have received particular attention for a wide range of therapeutic applications, and many approaches have been introduced to provide multifunctionality by evolving from pure to composite materials.1,2 Despite these advances, there is a disparity between fabricating hybrid systems and applying them in compliant clinical treatments, such as the practical use of injectable materials.3−5 Hydrogels have been introduced to meet the demands for injectability because they are easily malleable without cracking and maintain their tissue-like elasticity because of their high hydration properties.6−8 The injectability of hydrogels allows them to fill three-dimensional spaces in the tissue, thereby broadening their clinical applications from cosmetic products to localized drug delivery and regenerative cell therapies.4,9−12 To apply these developments to practical injectable hydrogel applications, granulization of a bulk hydrogel is a common procedure used to transform the gel into microsized particles © XXXX American Chemical Society
Received: May 21, 2019 Accepted: July 26, 2019
A
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
Figure 1. (A) Schematic illustration of fabrication of HA microspheres and crushed gel. (B) Optical images and (C) the size distribution of pure gel microspheres and crushed gels as well as each gel with precipitation.
the filler is inserted.14,17,34 Therefore, it is necessary to develop injectable gels with a uniform shape and a narrow size distribution range to achieve both excellent injectability and biomechanical strength. To address this challenge, in our work, HA-based hybrid hydrogel microspheres prepared using a water-in-oil (w/o) method and an in situ precipitation process are introduced. By applying phase separation between the HA solutions and oil and using continuous stirring, uniformly sized highly spherical hydrogel microparticles compared to conventional crushed gels can be obtained. Furthermore, to improve their mechanical strength and biophysical stabilities, in situ precipitation of nanosized calcium phosphate (CaP) was applied to the HA microspheres. For further evaluation, we compared our spherical hydrogel constructs, the pure HA microspheres and HA-based hybrid microspheres, with conventionally granulized gel particles. The shapes and morphologies were observed, and their injectability and rheological properties were also evaluated. Furthermore, the biostability of our microsphere systems was also explored both in vitro and in vivo using enzyme solutions and magnetic resonance imaging (MRI) after
over, by introducing biofunctional molecules or reactive moieties to HA, hydrogels with multifunctionality such as self-healing or shear-thinning properties can be obtained, which provide ease of injectability, leading to their advance in biomedical applications such as drug delivery and cell-based therapies.28−30 In addition, HA-based hybrid hydrogel particulates have been developed by incorporating bioactive ceramic nanoparticles using a precipitation process to enhance their structural stability under enzymatic degradation as well as their bioactivity to promote collagen tissue growth.31,32 Although the injectable nanocomposite system exhibits excellent biophysical properties, a high injection force resulting from the presence of nanosized ceramic fillers and nonuniform shapes and sizes of gel granules is unavoidable, thereby damaging the surrounding tissue and causing pain to the patient.17 It is difficult for large gel particles to penetrate smoothly through thin needles, and small gel particles are attacked by enzymes because of their large surface area, resulting in poor gel persistence.14,17,33 In some cases, uncrosslinked HA is mixed as a lubricant, which further reduces the strength and persistence of the gel when the same volume of B
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
Figure 2. (A)−(D) Characteristics of pure gel microspheres and those after precipitation. (A) SEM images, (B) FT-IR spectra, (C) XRD patterns, and (D) TGA curves of pure and precipitated HA microspheres.
particles of several tens of micrometers and large particles of several hundreds of micrometers coexisted. The average size of the particles was depended on the rotational speed of the homogenizer; however, its distribution was difficult to control. The gels had a wide size distribution with high average size by a slow rotational speed; however, the average size was excessively decreased with high speed; 265 ± 190, 222 ± 172, and 77 ± 74 μm, as the rotational speed was increased from 2000 rpm to 5000 and 8000 rpm (Figure S2). Comparing Sphere and Crush with similar averages, Crush had a much wider distribution than that for Sphere; average diameters were 222 ± 172 μm for Crush and 223 ± 69 μm for Sphere (Figure 1C). The range of the particle size distribution is important because it affects the extrusion force required for the injection.14,33 Not only the spherical shape but also the narrow distribution of Sphere makes this material more appropriate for injectable applications than Crush. Crush-P and Sphere-P, in which CaP nanoparticles were precipitated, were also examined, and their appearances were similar to those of the pure Crush and Sphere samples, respectively (Figure 1B). The particle sizes were 207 ± 146 and 211 ± 83 μm, respectively, similar to the each pure gels (Figure 1C). 2.2. Characteristics of Gel Microspheres. SEM images of the surfaces of the microspheres are presented in Figure 2A. Both Sphere and Sphere-P were spherical, without distortion after the precipitation. At high magnification, Sphere exhibited a smooth surface, whereas Sphere-P exhibited a nanoroughened surface because of the CaP precipitates.
subcutaneous injection, respectively. Remnant hydrogel formulations with a surrounding tissue were examined using histological stainings to verify their biocompatible and biostable properties. This comparative analysis is meaningful because there are limited reports comparing gel microspheres prepared by the w/o method with crushed gel particles, and the introduction of in situ precipitation in their production is a novel approach.
2. RESULTS AND DISCUSSION 2.1. Morphology of Gel Microspheres and Crushed Gels. The HA microspheres and HA crushed gels are referred to as Sphere and Crush, respectively, and the CaP-precipitated hybrid gels are referred to as Sphere-P and Crush-P, respectively. The appearance of the gel was examined using optical microscopy (OM). Sphere exhibited a completely spherical shape (Figure 1B) since HA solution is hydrophilic, while olive oil is hydrophobic; therefore, HA droplets were formed in the oil during rotation and were cross-linked. The size of the particles was adjustable by varying the rotational speed of the HA and oil emulsion. The diameter decreased from 896 ± 174 μm to 433 ± 124, 223 ± 69, and 97 ± 17 μm, as the rotational speed was increased from 200 rpm to 400, 800, and 1500 rpm. In all cases, the gel was formed into a perfectly spherical shape, and the particle size showed a normal distribution (Figure S1). The particle size of Crush was much more varied (Figure 1B). The gel was physically crushed by a homogenizer; however, it did not break into uniform shapes, and small C
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
Figure 3. (A)−(D) Characterization of cross-linking densities of gel microspheres and crushed gels: (A) 1H-NMR spectra of crushed gels and gel microspheres, (B) schematic images of cross-linking of HA, (C) degree of cross-linking of both gels, and (D) swelling ratio and water contents of the gels. The results are presented as the mean ± SD (n = 3).
Thus, the precipitate content was approximately 20 wt % regardless of the type of gel. 2.3. Characterization of Cross-Linking Density. The 1 H-NMR spectra used to characterize the cross-linking density of Crush and Sphere are presented in Figure 3A. For both Crush and Sphere, peaks appeared at 1.66 and 2.05 ppm, corresponding to protons of the alkyl groups in the crosslinking agent, 1,4-butanediol diglycidyl ether (BDDE) and protons of the N-acetyl groups in HA, respectively (Figure 3A,B). The degree of cross-linking was determined by comparing the relative peak integrals, and Crush and Sphere exhibited cross-linking densities of 21.22 and 28.09%, respectively (Figure 3C). Thus, the cross-linking density of Sphere was approximately 32% greater than that of Crush. The swelling ratio and water content of the gels were also examined (Figure 3D). Prior to comparison between Sphere and Crush, the analyses of the crushed gels and uncrushed bulk gels showed no significant difference, which means that the crushing process did not affect the wettability of the gels (Table S1). The swelling ratio of Sphere was 23%, which was lower than that of Crush (35%), indicating that Sphere had a higher cross-linking density than Crush. Because more crosslinking prevents the gel from absorbing much water, there is an inverse relationship between the swelling ratio and crosslinking density. In addition, the water contents of the precipitated gel were 96.24% for Crush-P and 94.99% for Sphere-P, representing reductions of approximately 1% from those of the pure gels because the CaP precipitates not only acted as a strengthening agent but also improved the bonding of the polymer chains. 2.4. Mechanical Properties of Gel Microspheres and Crushed Gels. The viscoelastic behaviors of the spherical and
FT-IR spectra of all the gel groups and HA powder are presented in Figure 2B. The characteristic peaks of HA appear at 1034, 1405, and 1607 cm−1. These peaks correspond to C− O stretching, alkyl groups (−CH), and carboxyl groups (−COOH), respectively. The broad peaks near 2891 and 3279 cm−1 correspond to the alkyl group (−CH) and hydroxyl group (−OH), respectively.35 These peaks were observed in the HA powder and were also clearly visible for all four types of gel samples. Therefore, the gel microspheres were formed well without residual oil or degradation of HA. For the precipitated gels, a peak corresponding to PO43− appeared at 556 cm−1, indicating the successful formation of CaP.36 The components of the precipitates were analyzed using XRD (Figure 2C). No peaks were observed for the pure gel. Small and broad peaks were observed for Sphere-P because the crystallinity of the precipitates was low, and the nanosized precipitates coexisted between polymer chains. Peaks appeared at approximately 26 and 32°, corresponding to CaP; thus, the composition of the precipitates was expected to be CaP. To more accurately confirm the composition, heat treatment was performed at 1250 °C for 30 min. The peaks were detached, and their compositions were determined to be hydroxyapatite and tricalcium phosphate. The amounts of the precipitates were analyzed using TGA (Figure 2D). All the TGA curves show similar tendencies. The initial weight loss was due to the evaporation of water and solvent, and the weight decreased until 500 °C because of the degradation of HA. After that, all the samples exhibited a residual mass. For Crush and Sphere, residues such as sodium carbonate remained at approximately 10%; however, Crush-P and Sphere-P exhibited a residual mass of approximately 30%. D
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
Crush showed liquid-like behavior where G′ varies with frequency, whereas Sphere exhibited a more solid-like and stiff characteristic with constant G′ regardless of the frequency. The G′ values of the gels were further increased by approximately 40% after precipitation to 1074 and 2381 Pa, respectively, and Crush-P exhibited predominantly elastic behaviors. In strain sweep, Sphere also exhibited higher G′ than Crush over the entire strain range. Furthermore, the linear viscoelastic region (LVR) was longer for precipitated gels, that is, the yield point of deformation (the critical strain) was higher than pure gel samples. This is because the CaP nanoparticles, which had formed homogeneously between the HA chains, entangled the HA chains, and the gel becomes ductile and can withstand large deformation. The complex viscosity (η*), which means the total ability of a material to withstand deformation, was calculated by considering the G′ and G″. Although all specimens showed shear thinning, the η* appeared in the same order as Sphere-P, Sphere, Crush-P, and Crush at all shear rates (Figure S3). Thus, the stiffness was remarkably increased for Sphere, especially after precipitation. In conclusion, the rheological properties of Sphere were similar to those reported for HA dermis fillers, indicating its appropriateness for injectable hydrogels in therapeutic applications.15,37,38 Furthermore, Sphere-P exhibited improved properties and is thus suitable for the treatment of deep wrinkles or severe skin deformities as well as the treatment of knee joints with high load bearing. 2.5. Injectability of Gel Microspheres and Crushed Gels. The injectability was analyzed by measuring the injection force (Figure 4B). Crush required an injection force of approximately 20 N, whereas Sphere was easily injected using an injection force of approximately 5 N, demonstrating its improved injectability. For Crush, large particles occasionally blocked the needles and increased the injection force. However, Sphere passed through the needle without clogging because of its relatively narrow size distribution and uniform spherical shape. The effect of precipitate particles on the injection force was also evaluated. For Crush-P, the gels became stiffened after precipitation, resulting in an increased injection force. SphereP was also stiffened, resulting in an increase of the injection force; however, it was still released below 10 N without a rapid increase in force. The relationship between G′ and injection force is summarized in Figure 4C. G′ was determined at a strain of 1% and a frequency of 6.3 rad/s, and the injection force was averaged over a linear 2 mm section.39 Crush was prepared using various amounts of BDDE, and there was an exponential relationship between G′ and the injection force. Also, the Sphere group was confirmed to exhibit a low injection force and high G′. In general, HA particles with higher G′ values are more difficult to inject, even if the gel particles are very small because it is difficult to pass a stiffened gel through a needle.17 However, despite high G′, both Sphere and Sphere-P required significantly lower injection forces due to their uniform size and shape compared to crushed gels. Overall, compared with the conventional crushed products, Sphere-P exhibited improved mechanical properties owing to the combination of its high G′ and high injectability. 2.6. In Vitro and In Vivo Degradation Behaviors. The biodegradability of the gels was confirmed by analyzing the degradation behavior both in vitro and in vivo. For an in vitro analysis, in all the cases, the residual weight of the gel increased
crushed gels were investigated using a rheometer, as shown in Figure 4A. The storage moduli (G′) of all the samples were
Figure 4. (A)−(C) Mechanical and injectional properties of crushed gels and gel microspheres and each gel with precipitation. (A) Rheological behavior showing storage modulus for frequency sweep and (B) injectability of each gel. (C) Relationship between injectability and storage modulus graph of HA gels. The results are presented as the mean ± SD (n = 3).
shown to be more dominant than the loss moduli (G″) over the full range of angular frequency (data not shown), indicating that highly elastic behaviors were achieved. In addition, Sphere exhibited a much higher G′ than Crush over the full range of frequency. For frequency sweeps, G′ at 6.3 rad/s was 735 Pa for Crush and more than doubled to 1764 Pa for Sphere because of the enhanced cross-linking. Furthermore, E
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
white part corresponds to the residual gel and surrounding tissues because MRI detects moisture. Sphere-P appeared to be maintained more, followed by Sphere; however, Crush appeared to be more widespread and less remained. After 8 weeks, Sphere-P became darker indicating its water content was relatively low compared with that of the pure gel. After 28 weeks, Sphere-P maintained a significantly high volume, followed by Sphere, and Sphere was less diffused and more rounded than Crush. The entire volume was measured by calculating the area of fillers in 2D images and stacking them (Figure 6B). Crush showed a significant decrease compared with Sphere groups at 1 week, and there was a significant difference between the three groups after 8 weeks. When all three groups were expressed as a spline-β line, the volume of residual gel was decreased linearly; Crush and Sphere exhibited a sharp decrease between 4 and 8 weeks, and Sphere-P showed a rapid decrease between 16 and 20 weeks. At 28 weeks, SphereP, Sphere, and Crush exhibited residual gel volumes of 45, 36, and 23%, respectively. That is, in addition to the precipitation, only pure Sphere had significantly improved stability and maintained a round shape of the gel bundle better than pure Crush, which is consistent with the previous evaluations. 2.7. In Vivo Histological Observation. The histology was analyzed after staining to evaluate the bioactivity and tissue regeneration. In hematoxylin and eosin (H&E) staining, the blue color corresponds to the remaining gel, and the purple color corresponds to the soft tissue (Figure 7A,B). The white part corresponds to the empty space created by the partial removal of the gel during the process of dehydration and paraffin treatment, which is a pretreatment process used for histological staining. For Crush, the gel was fully depressed, whereas for Sphere, an extensive fibrous tissue was observed between the gels (Figure 7A). Sphere retained its original shape from an external force because the stiff gels exhibited high resistance to deformation. Furthermore, spherical-shaped particles are in point contact with other particles, while irregular-shaped particles make surface contact with other particles, reducing the volume of pores. Therefore, Sphere resulted in better volume restoration than that of Crush. In addition, the tissue could infiltrate and regenerate between the gels. This is beneficial in which the injected gel maintains its
in the early stage because the initial degradation loosened the polymer chains and increased water absorption (Figure 5).40
Figure 5. In vitro degradation behaviors of the gel by hyaluronidase at 7 UI/mL. The results are presented as the mean ± SD (n = 3).
After that, further degradation occurred, and the mass decreased. After 24 h, the residual weight of Crush remained at approximately 30%; however, that of Sphere was almost 100%, indicating that Sphere was more stable than Crush. The first explanation for this result is that the high cross-linking reduced the swelling ratio and increased the enzymatic resistance of the HA chain against hyaluronidase.41 Furthermore, Sphere is likely to be longer lasting because of its relatively uniform size and small surface area, whereas Crush is a mixture of large and small particles and has a large surface area, which can be easily attacked by external enzymes. In addition, the precipitated gels exhibited higher stability than the pure gels because CaP particles acted as cross-linking agents between HA chains to enhanced persistence. Therefore, Sphere-P was the most stable under in vitro physiological conditions. Based on the demonstrated degradation resistance properties, the in vivo volumetric persistence of the Sphere groups under the skin was also evaluated using MRI and compared with that of Crush. Figure 6A presents cross-sectional images of the center of the injected gel as a function of time. The
Figure 6. (A, B) In vivo degradation behaviors over time: (A) MRI images of crushed gels, gel microspheres, and gel microspheres with precipitation at 0, 8, 16, and 28 weeks after injection (scale bars: 1 mm). (B) Remaining volume of each gel as a function of time until 28 weeks. The results are presented as the mean ± SD (n = 5). F
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
Figure 7. (A)−(G) Histologically stained tissues injected with crushed gels, gel microspheres, and gel microspheres with precipitation after 12 weeks of injection. (A, B) H&E stained images and (C) density of fibroblasts in ingrowth tissue. (D) Masson’s trichrome-stained images and (E) collagen area in ingrowth tissue. (F) Masson’s trichrome-stained images and (G) dermal thickness in dermis. The results are presented as the mean ± SD (n = 3, **P < 0.01). (Scale bars for (A) = 1 mm, for (B) = 50 μm, and for (C, D) = 120 μm).
receptors of the transforming growth factor beta (TGF-β).46 It has been reported that gene expression including SMAD2 and SMAD3 were higher in the hyaluronic acid (HA) composites containing CaP than pure HA.47 Therefore, in Sphere-P, the released Ca2+ promoted expression of a TGF-containing growth factor through a SMAD pathway, resulting in an increased fibroblast density and tissue formation. In addition, immunohistochemical staining with an antiCD68 antibody was performed to confirm the immune response. Macrophages should be stained brown; however, it was difficult to see macrophages in all the groups, and there was no difference from normal tissues. For Sphere-P, the many blue dots are indicating nonimmune cells, but the normal cells were detected; thus, they can be regarded as fibroblasts. Quantitative analysis revealed no difference in the expression of CD68 among the three experimental groups (Figure S4). Masson’s trichrome staining was also performed to confirm the maturity of the tissue, as shown in Figure 7D,F. Collagen appears blue; therefore, a higher blue ratio indicates a more matured fibrous tissue. Crush had a little tissue and was reddish, whereas Sphere was partially blue, and Sphere-P was mostly blue in an ingrowth tissue (Figure 7D). Sphere-P was more biocompatible because of bioactive CaP and mechanical strengthening; therefore, the fibroblasts could stretch for a robust collagen synthesis. There was a significant difference in the area of collagen in the generated tissue among the three groups, as observed in Figure 7E. Biological responses on the dermis were also examined. The dermal thickness after filler injection was analyzed (Figure 7F). When the filler was inserted, the upper dermis tissue was
volume well, the large contact area reduces foreign body reactions, and the regenerated tissue maintains the space even after the degradation of the gel. Furthermore, more regeneration was observed for Sphere-P, and this difference was more apparent at high magnification (Figure 7B). It is difficult to find any regenerated tissue or cells in Crush; however, regenerated tissue with fibroblasts was formed between the gels in Sphere. In addition, Sphere-P showed improved tissue regeneration with more fibroblasts, the purple dots. Red dots (endothelium) are also observed in a rounded collection, which indicates that the blood vessels were formed after maturation of the new tissue. The fibroblast densities are presented in Figure 7C, and Sphere showed a significant increase compared with that of Crush. Also, Sphere-P was further increased compared with that of the other two specimens. The promotion of tissue formation for Sphere-P was affected by two reasons. First, the adhesion and proliferation of fibroblasts are enhanced by the increase in stiffness of the hydrogel.42,43 Because stiffer gel maintains its shape well in the body and provides a large space for cell attachment, fibroblasts attach well forming the collagen and ECM for dermal tissue. Thereby, the proliferation of fibroblasts and tissue regeneration were improved. Furthermore, the CaP nanoparticles induced significant fibroblast cell migration from the surrounding tissue and stimulated the biological response for the generation of collagen and ECM production.44,45 The mechanism can be explained by the effect of calcium ions (Ca2+). The Ca2+ signal activated the biological function of fibroblasts by enhancing the activation of SMAD, which is the main signal transducers for G
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
atures (below 37 °C) has been identified to be more beneficial in enhancing physical properties, than at conventional condition (around 37 °C or higher).49 The cross-linked HA microspheres were vacuum filtered using a Buchner funnel with a quantitative filter paper (Advantec, CA, USA; pore 1 μm, thickness 0.22 mm) to remove olive oil. The filter paper was placed on the Buchner funnel above a triangular filtering flask, and a rotary pump was connected to the flask to hold the vacuum. The washing solution was repeatedly poured into the filter paper in a volume of 100 mL at a time. The washing solution was initially 70% acetone aqueous solution, gradually decreasing the concentration, and finally, distilled water (DW) and PBS were used. After that, 2 g of microspheres were immersed in 10 mL of PBS for 2 h, and PBS was replaced every 30 min for complete washing. Then, the microspheres were swollen in PBS at 37 °C for 24 h. Swollen microspheres were separated from PBS using gravity filtering and were used in the experiments. To prepare the hybrid microspheres, CaP nanoparticles were precipitated inside the gel. After filtering and washing the residual oil, the pure HA microspheres were immersed in 0.145 M calcium chloride (CaCl2) and 0.087 M phosphoric acid (H3PO4) solution for 2 h. They were then immersed in 10% (v/v) ammonium hydroxide (NH4OH) solution for 30 min. The residue was removed by washing with PBS, and the hybrid microspheres were fully swollen in PBS at 37 °C for 24 h. A schematic illustration of the fabrication process of the gel microspheres and crushed gels is presented in Figure 1A. 4.3. Fabrication of Crushed Gels. The crushed gels were fabricated by preparing a bulk HA gel and crushing it. After mixing BDDE and 10% (w/v) HA solutions at 2% (v/v), 1 mL of each solution was sealed in a polyethylene mold and crosslinked at 25 °C for 4 days. The cross-linked bulk gel was washed with PBS for 2 h to remove residual BDDE and then swollen at 37 °C for 24 h. After the surface of the swollen gel was wiped, it was crushed for 4 min at 2000, 5000, and 8000 rpm using a homogenizer (T18 digital ULTRA-TURRAX, IKA, Staufen, Germany). For the hybrid crushed gels, the same process was performed on the bulk hydrogel. CaP nanoparticles were precipitated inside the gel. After washing, the bulk HA gel was immersed in 0.145 M CaCl2 and 0.087 M H3PO4 solutions for 2 h and then in 10% (v/v) NH4OH solution for 30 min, in sequence. The residue was removed by washing with PBS, and the bulk hybrid gels were fully swollen in PBS at 37 °C for 24 h and then crushed under the same conditions. 4.4. Characterization of HA Gel Particles. The swollen gels were observed using optical microscopy (OM; Dimis-M, Siwon Optical Technology, Gyeonggi-do, Korea) after staining with 3% (w/v) alcian blue in 1% (v/v) acetic acid solution. The sizes of all gels were analyzed using Image J program (National Institutes of Health, MD, USA). The gels were also characterized using Fourier-transform infrared (FT-IR) spectroscopy (Nicolet iS50, Thermo Fisher Scientific, MA, USA) for wavenumbers ranging from 400 to 4000 cm−1 with an average of 32 scans after lyophilization. The cross-linking density was determined using 1H-NMR spectroscopy (AVANCE-500, Bruker, MA, USA). Crush and Sphere were dissolved in deuterium oxide after treatment with 0.01 mg/mL (7 UI/mL) hyaluronidase solution for 5 days and then dried.50,51 The cross-linking density was calculated by comparing the ratio of the relative peak integrals of 2.05 ppm;
stretched and thinned. Using the bioactive filler, the dermis was stimulated, and the dermal thickness approached the original state. The thicknesses of Crush and Sphere were similar (approximately 100 μm), whereas that of Sphere-P was approximately 180 μm (Figure 7G). The references indicate that the dermal thickness of the nude mouse is approximately 200 μm;48 therefore, Sphere-P almost recovered its original thickness. The CaP particles promoted cell growth and tissue formation. In conclusion, we expect Sphere-P hydrogels, which possess excellent biostability and biocompatibility, to be suitable for injectable filler clinical applications.
3. CONCLUSIONS In this study, HA microspheres were successfully fabricated using a w/o emulsion process and were compared with conventional crushed gels cross-linked in bulk. The Sphere gels were fabricated with a relatively uniform size and a completely spherical shape, and their size was easily controllable by adjusting the rotational speed. Sphere had enhanced crosslinking density compared with Crush, resulting in a lower swelling ratio and improved mechanical properties. Furthermore, the injectability was significantly increased due to the narrow size distribution and spherical shape. The biostability was also improved because of the higher cross-linking density and reduced surface area resulting from the relatively uniform size. This tendency was further improved after in situ CaP precipitation, which resulted in a significant increase in strength and biostability with only a negligible increase in the injection force. These effects were confirmed in in vivo tests. Sphere was significantly more biostable than Crush, and the shape of the filler was well retained. In addition, for Sphere, new tissues grew by infiltration between the HA gels, and the area of collagen in ingrowth tissues also increased. For SphereP, the CaP nanoparticles stimulated cell growth and tissue formation, resulting in the formation of more matured tissues and having a positive effect on the dermis. Therefore, Sphere shows better potential for injectable hydrogel applications than Crush in terms of the rheological properties, bioactivity, and biostability, and these properties were further improved after CaP precipitation. 4. EXPERIMENTAL SECTION 4.1. Materials. Biograde HA sodium salt with a molecular weight of 1.8−2.5 MDa and a purity of 99.84 + % produced by fermentation of Streptococcus zooepidemicus was purchased from SK Bioland, Cheonan, Korea. Phosphate-buffered saline (PBS) was obtained from Welgene, Gyeongsangbuk-do, Korea, and zoletil was supplied from Virbac, Carros, France. Rompun was obtained from Bayer, Leverkusen, Germany, and the antiCD68 antibody was supplied form Biorbyt, Cambridge, UK. All the other chemicals were purchased from Sigma-Aldrich, MO, USA. 4.2. Fabrication of Gel Microspheres. The HA microspheres were prepared using a w/o emulsion technique. First, the HA powders were gently stirred in 0.2 M sodium hydroxide (NaOH) solution at 10 °C overnight to prepare a 10% (w/v) HA solution. The cross-linking agent, BDDE, was mixed with the prepared HA solution at 2% (v/v) and emulsified in olive oil at 10% (v/v). After 1 h, the stirring speed was fixed at the desired levels, that is, 200, 400, 800, and 1500 rpm. The cross-linking was performed at 25 °C for 4 days with stirring because long-term cross-linking at low temperH
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
the protons of the N-acetyl group in HA, to 1.66 ppm, the protons of the alkyl group in BDDE. 4.5. Characterization of CaP Nanoparticles in SphereP. The properties of CaP nanoparticles were evaluated after drying the gel particles at room temperature. The surface of Sphere-P was characterized using field-emission scanning electron microscopy (FE-SEM; MERLIN Compact, Carl Zeiss Inc., Oberkochen, Germany) under an accelerating voltage of 2 kV. The crystalline phases were characterized using X-ray diffraction (XRD; D8-Advance, Bruker Co., Karlsruhe, Germany) over the scanning range of 20−60°. The CaP content was quantified using a thermogravimetric analysis (TGA; simultaneous DTA/TGA analyzer, TA Instruments, DE, USA). Before the analysis, the gels were completely dried in air and heated to 1000 °C at a rate of 10 °C/min under air condition. 4.6. Mechanical Properties and Injectability. The rheological behaviors of all the gels were analyzed using a rheometer (Discover HR-2, TA Instruments, DE, USA) with a parallel-plate geometry. All the swollen gels were prepared in a syringe in a volume of 1 mL and dispensed onto the bottom plate, and then the top plate with a 20 mm diameter was plated in a gap of 2.8 mm. Frequency sweep tests were performed in the frequency range of 0.1−100 rad/s at a strain of 0.1%. Strain sweep tests were performed over the strain range of 0.01− 100% at a frequency of 1 Hz. The injection force was measured using a universal testing machine (Instron 3343, Instron, MA, USA) with a 50 Ncapacity load cell. A 1 mL syringe was filled with 0.8 mL of each gel, and a 27-gauge needle was inserted. After that, a compression force was applied vertically at a crosshead speed of 10 mm/min, and the force when the gel was released through the needle was measured. A plot of the storage modulus (G′) as a function of the injection force was obtained for various BDDE concentrations of the crushed gels (1, 2, 4, 6, 8, and 16% (v/v)). 4.7. Swelling Ratio and Degradation Behavior. The swelling ratio was calculated from the weights of the swollen and dried gel. All the gels were swollen in PBS solution at 37 °C for 24 h, and the swollen weight (ws) was measured. They were then dried in a vacuum oven and weighed to obtain the dried weight (wd). The swelling ratio and water content of each gel were calculated using the following equations:
group for histology). After feeding the mice a standard diet and allowing them to rest for 2 weeks, the mice were anesthetized via an intraperitoneal injection of zoletil (30 mg/kg) and rompun (5 mg/kg). After the anesthetic was administered, 200 μL of each gel was injected into the back of each mouse between the panniculus adiposus layer and panniculus carnosus, with a total of 4 injections per mouse (Figure S5). The in vivo animal experiment was approved by the Institutional Animal Care and Use Committee of Seoul National University (IACUC protocol no. 18-0014). 4.9. Volumetric and Histological Analyses. All the groups were examined using the MRI volumetric analysis under isoflurane/O2 (1.5% isoflurane, 1.0 L/min O2) immediately after the injection and after the first week and every 4 weeks up to 28 weeks. A magnetic resonance scanner (Agilent 9.4 T/160AS, Agilent Technologies, CA, USA) and a 1H surface coil (Millipede Coil, Agilent Technologies, CA, USA) were used for the MRI analysis. Both T2-weighted axial and coronal images were obtained. The slice thicknesses of the axial and coronal image were 0.3 and 1.0 mm, respectively. The axial T2-weighted image was used for the volumetric analysis performed using Image J program. For histological observation, the injected gels and surrounding tissue were extracted at 12 weeks. They were immediately fixed in 10% formalin for 24 h and then gradually dehydrated with ethanol and embedded in paraffin. The paraffin blocks were sectioned into 4 μm thicknesses. The slices were stained with hematoxylin and eosin (H&E) and Masson’s trichrome to visualize the remaining gel and infiltrated as well as the surrounding tissue. The analyses of the collagen area and dermal thickness were performed using Image J program. 4.10. Statistical Analysis. All the assays were performed with a minimum of n = 3 per group. All the quantitative variables are presented as means ± standard deviations. The data were analyzed using the Statistical Package for the Social Sciences (SPSS) (IBM, NY, USA), statistical software program. For multiple comparisons between the groups, a one-way analysis of variance (ANOVA) and a Tukey’s posthoc analysis were used. The statistical significance was set at **p < 0.01.
■
ASSOCIATED CONTENT
S Supporting Information *
The Supporting Information is available free of charge on the ACS Publications website at DOI: 10.1021/acsomega.9b01475. Size distribution of hyaluronic acid hydrogel microspheres and crushed gel particles, swelling ratio and water contents of bulk gels and crushed gels, rheological behaviors of the hydrogels, experimental method and resulting data of immunohistochemical analysis, and optical images of nude mice after hydrogel filler injection (PDF)
swelling ratio(%) = (ws − wd)/wd × 100 sater content(%) = (ws − wd)/ws × 100
The degradation behavior was assessed by measuring the weight of each gel over time in the hyaluronidase solution. Each gel was immersed in hyaluronidase solution diluted to 0.01 mg/mL (7 UI/mL) in PBS at 37 °C. The initial weight (wi) was measured at the beginning, and the remaining weight (wr) was measured at each time point. The remaining weight of each gel was calculated using the following equation:
■
remaining weight (%) = (wr /wi) × 100
AUTHOR INFORMATION
Corresponding Authors
4.8. In Vivo Assessment. Six-week-old female BALB/c nude mice were obtained from a commercial vendor (Orient Bio Inc., Seongnam, Korea). In total, seven mice were used (four for the MRI analysis and three for the histological analysis), and three types of injections were performed randomly for each mouse four times: (i) Crush, (ii) Sphere, and (iii) Sphere-P (n = 5 per group for MRI, and n = 3 per
*E-mail:
[email protected]. Phone: +82 2 2072 3530. Fax: +82 2 3675 3680 (S.K.). *E-mail:
[email protected]. Phone: +82 2 880 8320. Fax: +82 2 884 1413 (S.-H.J.). ORCID
Hyoun-Ee Kim: 0000-0001-8542-0124 I
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
(20) Boni, R.; Ali, A.; Shavandi, A.; Clarkson, A. N. Current and novel polymeric biomaterials for neural tissue engineering. J. Biomed. Sci. 2018, 25, 90. (21) Burdick, J. A.; Prestwich, G. D. Hyaluronic acid hydrogels for biomedical applications. Adv. Mater. 2011, 23, H41−H56. (22) Borzacchiello, A.; Russo, L.; Malle, B. M.; Schwach-Abdellaoui, K.; Ambrosio, L. Hyaluronic acid based hydrogels for regenerative medicine applications. BioMed Res. Int. 2015, 2015, 871218. (23) Mealy, J. E.; Chung, J. J.; Jeong, H. H.; Issadore, D.; Lee, D.; Atluri, P.; Burdick, J. A. Injectable Granular Hydrogels with Multifunctional Properties for Biomedical Applications. Adv. Mater. 2018, 30, 1705912. (24) Toole, B. P. Hyaluronan in morphogenesis. Semin. Cell Dev. Biol. 2001, 12, 79−87. (25) Collins, M. N.; Birkinshaw, C. Hyaluronic acid based scaffolds for tissue engineeringA review. Carbohydr. Polym. 2013, 92, 1262− 1279. (26) Nurunnabi, M.; Revuri, V.; Huh, K. M.; Lee, Y.-K. Chapter 14 Polysaccharide based nano/microformulation: an effective and versatile oral drug delivery system. In Nanostructures for Oral Medicine; Andronescu, E.; Grumezescu, A. M., Eds. Elsevier: 2017; pp 409−433. (27) Hachet, E.; Van Den Berghe, H.; Bayma, E.; Block, M. R.; Auzély-Velty, R. Design of Biomimetic Cell-Interactive Substrates Using Hyaluronic Acid Hydrogels with Tunable Mechanical Properties. Biomacromolecules 2012, 13, 1818−1827. (28) Rodell, C. B.; Kaminski, A. L.; Burdick, J. A. Rational Design of Network Properties in Guest−Host Assembled and Shear-Thinning Hyaluronic Acid Hydrogels. Biomacromolecules 2013, 14, 4125−4134. (29) Widjaja, L. K.; Bora, M.; Chan, P. N. P. H.; Lipik, V.; Wong, T. T.; Venkatraman, S. S. Hyaluronic acid-based nanocomposite hydrogels for ocular drug delivery applications. J. Biomed. Mater. Res., Part A 2014, 102, 3056−3065. (30) Ye, X.; Li, X.; Shen, Y.; Chang, G.; Yang, J.; Gu, Z. Self-healing pH-sensitive cytosine- and guanosine-modified hyaluronic acid hydrogels via hydrogen bonding. Polymer 2017, 108, 348−360. (31) Jeong, S. H.; Koh, Y. H.; Kim, S. W.; Park, J. U.; Kim, H. E.; Song, J. Strong and Biostable Hyaluronic Acid-Calcium Phosphate Nanocomposite Hydrogel via in Situ Precipitation Process. Biomacromolecules 2016, 17, 841−851. (32) Vallés-Lluch, A.; Poveda-Reyes, S.; Amorós, P.; Beltrán, D.; Monleón Pradas, M. Hyaluronic Acid−Silica Nanohybrid Gels. Biomacromolecules 2013, 14, 4217−4225. (33) Attenello, N. H.; Maas, C. S. Injectable fillers: review of material and properties. Facial Plast. Surg. 2015, 31, 29−34. (34) Chun, C.; Kim, Y.; Son, S.; Lee, D. Y.; Kim, J. T.; Kwon, M. K.; Kim, Y. Z.; Kim, S. S. Viscoelasticity of hyaluronic acid dermal fillers prepared by crosslinked HA microspheres. Polymer 2016, 40, 600− 606. (35) Yang, Y.; Zhao, Y.; Lan, J.; Kang, Y.; Zhang, T.; Ding, Y.; Zhang, X.; Lu, L. Reduction-sensitive CD44 receptor-targeted hyaluronic acid derivative micelles for doxorubicin delivery. Int. J. Nanomed. 2018, 13, 4361−4378. (36) Song, E.-H.; Seong, Y.-J.; Kim, J.; Kim, H.-E.; Jeong, S.-H. Multilayered Polyurethane−Hydroxyapatite Composite for Meniscus Replacements. Macromol. Mater. Eng. 2019, 304, 1800352. (37) Sinclair, A.; O’Kelly, M. B.; Bai, T.; Hung, H.-C.; Jain, P.; Jiang, S. Self-Healing Zwitterionic Microgels as a Versatile Platform for Malleable Cell Constructs and Injectable Therapies. Adv. Mater. 2018, 30, 1803087. (38) Kochhar, A.; Wu, I.; Mohan, R.; Condé-Green, A.; Hillel, A. T.; Byrne, P. J.; Elisseeff, J. H. A Comparison of the Rheologic Properties of an Adipose-Derived Extracellular Matrix Biomaterial, Lipoaspirate, Calcium Hydroxylapatite, and Cross-linked Hyaluronic Acid. JAMA Facial Plast. Surg. 2014, 16, 405−409. (39) Lee, H.-Y.; Hwang, C.-H.; Kim, H.-E.; Jeong, S.-H. Enhancement of bio-stability and mechanical properties of hyaluronic acid hydrogels by tannic acid treatment. Carbohydr. Polym. 2018, 186, 290−298.
Seol-Ha Jeong: 0000-0003-3210-9580 Notes
The authors declare no competing financial interest.
■
ACKNOWLEDGMENTS
■
REFERENCES
This study was supported by the BK21PLUS SNU Materials Division for Educating Creative Global Leaders Program (21A20131912052).
(1) Nair, L. S.; Laurencin, C. T. Biodegradable polymers as biomaterials. Prog. Polym. Sci. 2007, 32, 762−798. (2) Kohane, D. S.; Langer, R. Polymeric biomaterials in tissue engineering. Pediatr. Res. 2008, 63, 487−491. (3) Neuberger, T.; Schöpf, B.; Hofmann, H.; Hofmann, M.; von Rechenberg, B. Superparamagnetic nanoparticles for biomedical applications: Possibilities and limitations of a new drug delivery system. J. Magn. Magn. Mater. 2005, 293, 483−496. (4) Tibbitt, M. W.; Anseth, K. S. Hydrogels as extracellular matrix mimics for 3D cell culture. Biotechnol. Bioeng. 2009, 103, 655−663. (5) Portnov, T.; Shulimzon, T. R.; Zilberman, M. Injectable hydrogel-based scaffolds for tissue engineering applications. Rev. Chem. Eng. 2017, 33, 91−107. (6) Fedorovich, N. E.; Alblas, J.; De Wijn, J. R.; Hennink, W. E.; Verbout, A. J.; Dhert, W. J. Hydrogels as extracellular matrices for skeletal tissue engineering: State-of-the-art and novel application in organ printing. Tissue Eng. 2007, 13, 1905−1925. (7) Yu, L.; Ding, J. Injectable hydrogels as unique biomedical materials. Chem. Soc. Rev. 2008, 37, 1473−1481. (8) El-Sherbiny, I. M.; Yacoub, M. H. Hydrogel scaffolds for tissue engineering: Progress and challenges. Global cardiology science & practice 2013, 2013, 316−342. (9) Kim, Z. H.; Lee, Y.; Kim, S. M.; Kim, H.; Yun, C. K.; Choi, Y. S. A composite dermal filler comprising cross-linked hyaluronic acid and human collagen for tissue reconstruction. J. Microbiol. Biotechnol. 2015, 25, 399−406. (10) Yun, Y. H.; Goetz, D. J.; Yellen, P.; Chen, W. Hyaluronan microspheres for sustained gene delivery and site-specific targeting. Biomaterials 2004, 25, 147−157. (11) El-Khalawany, M.; Fawzy, S.; Saied, A.; Al Said, M.; Amer, A.; Eassa, B. Dermal filler complications: a clinicopathologic study with a spectrum of histologic reaction patterns. Ann. Diagn. Pathol. 2015, 19, 10−5. (12) Dib, N.; Khawaja, H.; Varner, S.; McCarthy, M.; Campbell, A. Cell Therapy for Cardiovascular Disease: A Comparison of Methods of Delivery. J. Cardiovasc. Trans. Res. 2011, 4, 177−181. (13) Chan, K. M. C.; Li, R. H.; Chapman, J. W.; Trac, E. M.; Kobler, J. B.; Zeitels, S. M.; Langer, R.; Karajanagi, S. S. Functionalizable hydrogel microparticles of tunable size and stiffness for soft-tissue filler applications. Acta Biomater. 2014, 10, 2563−2573. (14) Kablik, J.; Monheit, G. D.; Yu, L.; Chang, G.; Gershkovich, J. Comparative physical properties of hyaluronic acid dermal fillers. Dermatol. Surg. 2009, 35, 302−312. (15) Falcone, S. J.; Berg, R. A. Crosslinked hyaluronic acid dermal fillers: a comparison of rheological properties. J. Biomed. Mater. Res., Part A 2008, 87, 264−71. (16) Pierre, S.; Liew, S.; Bernardin, A. Basics of dermal filler rheology. Dermatol. Surg. 2015, 41, S120−S126. (17) Tezel, A.; Fredrickson, G. H. The science of hyaluronic acid dermal fillers. J. Cosmet. 2009, 10, 35−42. (18) Allison, D. D.; Grande-Allen, K. J. Review. Hyaluronan: a powerful tissue engineering tool. Tissue Eng. 2006, 12, 2131−40. (19) Kobayashi, H.; Terao, T. Hyaluronic acid-specific regulation of cytokines by human uterine fibroblasts. Am. J. Physiol. 1997, 273, C1151−C1159. J
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX
ACS Omega
Article
(40) Domingues, R. M. A.; Silva, M.; Gershovich, P.; Betta, S.; Babo, P.; Caridade, S. G.; Mano, J. F.; Motta, A.; Reis, R. L.; Gomes, M. E. Development of Injectable Hyaluronic Acid/Cellulose Nanocrystals Bionanocomposite Hydrogels for Tissue Engineering Applications. Bioconjugate Chem. 2015, 26, 1571−1581. (41) Tang, D. W.; Yu, S. H.; Wu, W. S.; Hsieh, H. Y.; Tsai, Y. C.; Mi, F. L. Hydrogel microspheres for stabilization of an antioxidant enzyme: effect of emulsion cross-linking of a dual polysaccharide system on the protection of enzyme activity. Colloids Surf., B 2014, 113, 59−68. (42) Discher, D. E.; Janmey, P.; Wang, Y. L. Tissue cells feel and respond to the stiffness of their substrate. Science (New York, N.Y.) 2005, 310, 1139−1143. (43) Ondeck, M. G.; Engler, A. J. Mechanical Characterization of a Dynamic and Tunable Methacrylated Hyaluronic Acid Hydrogel. J. Biomech. Eng. 2016, 138, No. 021003. (44) Volpi, N.; Schiller, J.; Stern, R.; Š oltés, L. Role, metabolism, chemical modifications and applications of hyaluronan. Curr. Med. Chem. 2009, 16, 1718−1745. (45) Bongio, M.; van den Beucken, J. J. J. P.; Nejadnik, M. R.; Leeuwenburgh, S. C. G.; Kinard, L. A.; Kasper, F. K.; Mikos, A. G.; Jansen, J. A. Biomimetic modification of synthetic hydrogels by incorporation of adhesive peptides and calcium phosphate nanoparticles: In vitro evaluation of cell behavior. Eur. Cells Mater. 2011, 22, 359−376. (46) Mukherjee, S.; Kolb, M. R. J.; Duan, F.; Janssen, L. J. Transforming growth Factor−β evokes Ca2+Waves and enhances gene expression in human pulmonary fibroblasts. Am. J. Respir. Cell Mol. Biol. 2012, 46, 757−64. (47) Jeong, S.-H.; Fan, Y.; Cheon, K.-H.; Baek, J.; Kim, S.; Kim, H.E. Hyaluronic acid-hydroxyapatite nanocomposite hydrogels for enhanced biophysical and biological performance in a dermal matrix. J. Biomed. Mater. Res., Part A 2017, 105, 3315−3325. (48) Xu, P.; Yu, Q.; Huang, H.; Zhang, W. J.; Li, W. Nanofat Increases Dermis Thickness and Neovascularization in Photoaged Nude Mouse Skin. Aesthetic Plast. Surg. 2018, 42, 343−351. (49) Baek, J.; Fan, Y.; Jeong, S.-H.; Lee, H.-Y.; Jung, H.-D.; Kim, H.E.; Kim, S.; Jang, T.-S. Facile strategy involving low-temperature chemical cross-linking to enhance the physical and biological properties of hyaluronic acid hydrogel. Carbohydr. Polym. 2018, 202, 545−553. (50) Lee, H.-Y.; Kim, H.-E.; Jeong, S.-H. One-pot synthesis of silanemodified hyaluronic acid hydrogels for effective antibacterial drug delivery via sol−gel stabilization. Colloids Surf., B 2019, 174, 308− 315. (51) Wende, F. J.; Gohil, S.; Nord, L. I.; Helander Kenne, A.; Sandström, C. 1D NMR methods for determination of degree of cross-linking and BDDE substitution positions in HA hydrogels. Carbohydr. Polym. 2017, 157, 1525−1530.
K
DOI: 10.1021/acsomega.9b01475 ACS Omega XXXX, XXX, XXX−XXX