Influence of Primary and Secondary Air Supply on Gaseous Emissions

Dec 12, 2017 - The emissions from traditional biomass combustion systems for cooking and heating are, globally, the main cause for premature mortality...
1 downloads 12 Views 2MB Size
Subscriber access provided by UNIV OF DURHAM

Article

Influence of primary and secondary air supply on gaseous emissions from a small-scale staged solid biomass fuel combustor Thomas Kirch, Cristian H. Birzer, Philip J. van Eyk, and Paul R. Medwell Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.7b03152 • Publication Date (Web): 12 Dec 2017 Downloaded from http://pubs.acs.org on December 18, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Influence of primary and secondary air supply on gaseous emissions from a small-scale staged solid biomass fuel combustor Thomas Kirch,∗,†,‡ Cristian H. Birzer,†,‡ Philip J. van Eyk,¶,‡ and Paul R. Medwell†,‡ †School of Mechanical Engineering, The University of Adelaide, Australia ‡Humanitarian and Development Solutions Initiative, The University of Adelaide, Australia ¶School of Chemical Engineering, The University of Adelaide, Australia E-mail: [email protected]

1

Abstract

2

The emissions from traditional biomass combustion systems for cooking and heat-

3

ing are, globally, the main cause for premature mortality due to air pollution. A staged

4

combustion process, that separates the thermochemical conversion of the solid fuel

5

and the combustion of the released products, offers potential to reduce harmful emis-

6

sions for solid fuel combustion and could therefore help mitigate the issue. In the

7

present study, the fundamental combustion behaviour of a small-scale staged com-

8

bustor was investigated with a focus on an independent systematic analysis of rel-

9

evant parameters. Natural and forced draft conditions as well as a combination of

10

both was tested. The relative location of primary to secondary air was also varied.

11

When lighting the fuel, higher airflows lead to faster ignition and lower emissions.

12

A steady-state combustion phase is achieved when gasification products are burned

1

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

13

with secondary air, which occurs mainly while the solid fuel is being pyrolysed. Af-

14

ter the steady-state phase, char remains as the solid pyrolysis product. Gasification

15

of the remaining char was found to release great amounts of CO, which are emit-

16

ted from the combustor, in the case of natural draft secondary air (SA). With higher

17

air flows of forced SA, an exceptionally high nominal combustion efficiency (NCE =

18

XCO2 /(XCO +XCO2 )) can be achieved in the steady-state phase. Forced SA flows cause

19

a longer duration of the steady-state phase from the combustion of raw biomass gasi-

20

fication products into the combustion of char gasification products. This extension

21

leads to a significant reduction of emissions of incomplete combustion. Additionally

22

smaller distances between the SA inlet and the fuel stack, caused lower emissions of

23

incomplete combustion. The combination of forced draft primary air and natural draft

24

SA presented worse combustor performance than under natural draft conditions.

2

ACS Paragon Plus Environment

Page 2 of 41

Page 3 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

25

1 Introduction

26

Approximately 2.8 billion people currently rely on solid biomass fuel to satisfy their cook-

27

ing and heating needs. 1 Globally, emissions caused by the use of traditional open fires or

28

simple cookstoves are the main cause of premature mortality due to air pollution. 2 This

29

includes 2.89 million and 2.93 million premature deaths annually related to household air

30

pollution from solid fuels and ambient particulate matter pollution, respectively. 3 These

31

findings illustrate the need for clean-burning cooking devices. A reduction of the amount

32

of pollutant emissions released from incomplete combustion through traditional cooking

33

methods could not only lead to health improvements, but also to social as well as envi-

34

ronmental benefits. 4,5

35

Staged combustors have demonstrated promising results as cookstoves in laboratory

36

studies, compared with other cookstoves. This type of combustor has been shown to pro-

37

duce low emissions of incomplete combustion, carbon monoxide (CO) and particulate

38

matter (PM), in cooking applications. 6,7 Other emissions, such as nitric oxides (NOx ),

39

can also be reduced through staged combustion . 8 The main feature which sets them

40

apart from other types of combustors is the use of pyrolysis and gasification to transform

41

the batch-fed solid biomass fuel into combustible gases, which are subsequently burned

42

separately in time and location. 9 The measurement of gaseous combustion products can

43

provide valuable information to gain a better understanding of the ongoing processes.

44

The two-staged combustion process is initiated by lighting the fuel from the top with

45

the aid of a kindling material. Lighting has been identified as a major source of emissions

46

of incomplete combustion where the higher heating value of the kindling material and

47

also the supply of forced air can be beneficial . 10 Lighting causes the combustion of the

48

top layer of solid biomass and consumes the oxygen in the combustor, creating a vitiated

49

environment leading to a so-called “migrating pyrolysis front” to establish in which only

50

partial oxidation occurs. This front moves opposite to the primary air (PA) flow, down the

51

fuel stack. Simultaneously, the pyrolysis products are burned separately at a secondary 3

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

52

air (SA) inlet . 11 This separation of pyrolysis and combustion processes is illustrated in

53

Figure 1. The remaining char, which accounts for 20-30% of the initial mass 12–14 , can

54

subsequently be burned or used for other purposes such as soil amendment. 15 Three suc-

55

cessive processes are most prominent in staged biomass combustors: lighting of kindling

56

material at the top of the fuel stack; the migrating pyrolysis where the release and com-

57

bustion of volatile compounds prevails; and the char gasification, where the remaining

58

char is converted into CO and CO2 through surface oxidation. A systematic analysis of

59

each of these phases could aid in decoupling processes to analyse individual parameters

60

in isolation.

61

The migrating pyrolysis front propagation, and thus the fuel conversion as well as the

62

heat release are controlled by the supply of PA. 12,16–23 It has been shown that forced air

63

can lead to a reduction of emissions of incomplete combustion. 24–26 Conversely, in some

64

cases it is possible that forced air staged combustion stoves, though energy efficient, may

65

not necessarily reduce emissions. 27 These contradictory findings reinforce the need for a

66

deeper understanding of the underlying processes to ensure emission efficiency of future

67

stove designs.

68

There is widespread belief that forced air, compared to natural draft, leads to greater

69

mixing and thus increased performance. 28,29 Many forced draft stoves are equipped with

70

one single fan that supplies air to both the PA and the SA inlets. The ratio of PA to SA is

71

then fixed, dependent on the stove geometry. 11 However, a few studies have been con-

72

cerned with the influence of PA 28,30–32 or the ratio of PA to SA 28,29,31,32 on the combustion

73

properties of the combustor. There is a paucity of scientific understanding of such systems

74

and the parameters that control the emissions. In particular, the influence of secondary

75

air flows as well as the relative location to the primary air flow is poorly understood in

76

small-scale staged combustion systems. In continuously-fed domestic biomass boilers it-

77

erative parametric investigation of staged air supply has been found to provide means to

78

decrease specific emissions 8,33,34 and could provide similar benefits for the studied com-

4

ACS Paragon Plus Environment

Page 4 of 41

Page 5 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

79

Energy & Fuels

bustion system.

80

The present parametric study was carried out in a research combustor to study and

81

gain a deeper understanding of the ongoing fundamental processes in small-scale staged

82

combustion devices. Preliminary tests under natural draft conditions set a baseline against

83

which alterations can be compared. Subsequently a combination of forced PA and natu-

84

ral draft SA are tested. Since the required air supply will change throughout the different

85

combustion phases it might be advantageous to entrain the SA via natural draft. Further

86

tests are conducted with a specified PA flow and variable SA flow, to study the influence

87

of an increasing air flow on the emissions of the combustion process. The relative loca-

88

tion of the SA inlet to the fuel stack is also considered. With a fixed location of the SA

89

inlet a varying distance of the air supply to the fuel might have an influence on the stove

90

performance.

91

In most research on cooking devices that use biomass fuel, the overall stove efficiency

92

is determined through tests that emulate user practices. This approach is dependent on a

93

multitude of variables, including the combustion and heat transfer properties as well as

94

handling by the user which has been shown to lead to high variability of results. 35,36 This

95

paper focusses solely on the fundamental combustion properties of a small-scale staged

96

combustor, enabling a more independent analysis of relevant parameters. Specifically,

97

the focus of the current work is on the role of the PA and SA supply, and their locations

98

relative to the fuel bed. A deeper understanding of the underlying combustion properties

99

could enable future optimisation of such devices, which is the motivation of this research.

100

2 Experimental Details

101

2.1

102

The research combustor used in the current work has previously been presented 32,37 and

103

shown in Figure2. It incorporates the principal features of a PA inlet at the bottom of

The Staged Combustor

5

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

104

the combustor, and a lateral SA inlet in the upper region. Its dimensions, were chosen

105

to be slightly larger than many commercial products (e.g. the Champion TLUD 11 ), es-

106

pecially the height. This increased size enables an investigation of scaling effects over a

107

wider range of combustion-relevant parameters, such as the fuel grate location. Impor-

108

tantly, the large diameter of the vessel provides a nearly one-dimensional reactor to facil-

109

itate subsequent modelling. The research combustor has been designed to advance the

110

fundamental-level understanding and to study the underlying physical processes. Thus

111

the combustor will be used to assess the combustion properties, not the cooking perfor-

112

mance. It is important to recognise that the current system does not include a pot on

113

top of the stove. If the secondary flame front were to interact with such a pot, localised

114

quenching could occur and subsequently lead to an increase in the emission of the prod-

115

ucts of incomplete combustion. However, with proper design and operation of a stove,

116

such effects would ideally not occur in an operational stove.

117

The steel cylinder combustor body has a diameter of 206 mm, a height of 600 mm and

118

a wall thickness of 8 mm. Inside the combustor body the fuel grate, on which the fuel

119

is placed, is held via three hooks. These are attached to the rim of the combustor body:

120

the fuel grate location is variable by adjusting the length of these hooks between 50 mm

121

and 570 mm below the SA inlet. The hooks enable the grate to be easily removable from

122

the combustor for post-combustion analysis of the solid residual matter, as well as for

123

cleaning. The grate is perforated with 3-mm-diameter holes, with an open-area ratio of

124

26%, which allows PA from beneath the grate to enter the fuel-stack. The combustor body

125

is placed on top of the PA inlet chamber.

126

2.1.1 Primary Air Configurations

127

The PA inlet chamber (dimensions: 248 mm × 248 mm × 150 mm) is equipped with

128

removable side walls. When the side walls are taken off, the air can enter freely over

129

the whole combustor body diameter via natural draft, and if closed off, air can be applied 6

ACS Paragon Plus Environment

Page 6 of 41

Page 7 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

130

through a controlled inlet. In the natural draft configuration, the amount of air that enters

131

is determined by the buoyancy force due to the pressure difference over the combustor

132

height during the combustion process. In the forced air configuration, the sides of the

133

chamber are closed off and the inlet is connected to dry compressed air. The in-flow is

134

controlled by a needle valve and a rotameter upstream of the inlet. Downstream of the

135

inlet, air passes through a diffuser ring with ten 1-mm-diameter holes. These holes in the

136

diffuser are directed downward which forces the air flow to be inverted before entering

137

the combustor body. The inversion of the PA flow leads to less swirl and a more uniform

138

airflow through the combustor body. Subsequently the flow through the combustor body

139

is influenced by the porous fuel bed. The air flow through direction in the combustor is

140

presented in Figure 2. In the present study, tests were performed in the natural draft as

141

well as the forced air configuration.

142

2.1.2 Secondary Air Configurations

143

The SA enters the combustor through three 190-mm long, 20-mm high, lateral openings.

144

These are located 285 mm below the top of the combustor extension, and 55 mm above the

145

exit plane of the combustor body. There are two different configurations which allow air

146

to enter either via natural draft or forced by introducing compressed air. For the natural

147

draft configuration, the three openings of the combustor extension, shown in Figure 2,

148

are open to the surroundings. In the forced air configuration, the inlet is enclosed by

149

a diffuser skirt. The forced air combustor extension has four inlets. All four inlets are

150

connected by hoses of equal length to a manifold. The manifold is situated downstream

151

of a needle valve and rotameter by which the inflow of dried compressed air is regulated.

152

These measures were taken to ensure a uniform flow throughout the skirt to enter the

153

combustor extension. In all forced air configurations PA and SA are separately controlled

154

via independent air supply lines.

7

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

155

2.2

Data Collection

156

The data collection set-up consists of emissions data being collected in one central lo-

157

cation while temperature data was constantly measured in two locations. The research

158

combustor was placed under a fume hood, which was connected to an extraction duct

159

and a fan to ensure that all emissions from the combustor were directed outside of the

160

laboratory. The measuring probe of a Testo 350XL gas analyser was placed 830 mm above

161

the exit plane, along the central axis of the research combustor. This sampling location

162

is at the interface of the fume hood and the extraction duct. The released gases from the

163

research combustor will expand upon leaving the combustor, mix with the surrounding

164

air and enter into the fume hood. The hood acts as an aerodynamic contraction, reducing

165

the 1060-mm intake down to a diameter of 185 mm at the point the measurements are

166

collected. The diameter of the fume hood intake compared with the research combustor

167

diameter ensures that all emissions from the reactor are collected. The high contraction

168

ratio of the fume hood promotes intense mixing of the gases, such that the emissions

169

from the combustor are well-mixed by the time they reach the measurement point. The

170

gas analyser was used to measure the CO, CO2 and H2 emissions at 1 Hz, on a dry ba-

171

sis. The resolution was 1 ppm for low emission levels (2000 ppm) of CO measurements. The resolution for CO2 measurements

173

was 0.01%. For all measurements, unburned hydrocarbons (methane, propane and bu-

174

tane) were below the detection limit, namely 100 ppm. Temperature data were collected,

175

at 1 Hz, via two K-type thermocouples inside the combustor body and the combustor

176

extension, shown in Figure 2 at locations A and B, respectively. For procedural purposes

177

temperatures were measured in location C, when needed, via an infra-red thermometer.

8

ACS Paragon Plus Environment

Page 8 of 41

Page 9 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

178

2.3

Test Procedure

179

The research combustor, with a wall thickness of 8 mm, has a higher thermal mass than

180

usual cookstoves. It therefore was deemed necessary to ensure that only pre-heated tests

181

were recorded, to minimise any influence on the combustion performance, although the

182

process can also be achieved with a cold start. After pre-heating the combustor a new

183

batch of fuel was introduced when the outer wall temperature in location C, shown in

184

Figure 2, measured 150° C. For kindling, 5 mL of methylated spirits (96% ethanol, CAS

185

# 67-63-0) was poured over the fuel stack and ignited when the outer wall temperature

186

reached 135°C. The chosen starting wall temperature of 135°C is below the temperature

187

encountered later in the burn-cycle. Therefore, thermal energy from the combustion goes

188

toward increasing the body temperature. However, it is not possible to preheat to a higher

189

temperature both for manual handling safety during the reload process, and also to avoid

190

volatilisation of the biomass fuel, which starts at approximately 200°C. 26

191

The fuel for each test consisted of 700 g of dried locally sourced pine chips (Pinus radi-

192

ata). The wood chips were obtained from various locations across the Mt Lofty ranges of

193

South Australia. They were sourced in-bulk, as pre-chipped material, and sieved through

194

a 25 mm aperture, resulting in an average particle size of 24 mm × 8 mm × 3 mm (length

195

× width × height). The bulk density of the dried pine chips is approximately 210 kg·m−3 .

196

This density and amount of fuel used led to a fuel bed height of 100 mm and a test dura-

197

tion of approximately 600 s. While a greater amount of fuel would extend the time spend

198

in the steady-state and char phase, it would not impact the findings. The proximate analy-

199

sis of the pine chips provided a composition of 16.8 % fixed carbon, 82.9 % volatile matter

200

and 0.4 % ash, mass fraction on dry basis. The ultimate analysis yielded mass fractions of

201

51.2 % C, 6.2 % H, 42.0 % O and 0.2 % N, on a dry basis. Pine chips were chosen as fuel

202

because wood is the most commonly combusted biomass. 38 The influence of the moisture

203

content has previously been studied 13 and is outside the scope of the presented research

204

study. To avoid the influence of inconsistent moisture content on the burning rate and the 9

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

205

emissions, 13 all the chips were dried prior to testing. This was done by keeping them for

206

16 hours in a confined space at a constant temperature of 37°C, created by an air condi-

207

tioning unit. The drying process resulted in a fuel moisture content of approximately 7 %

208

determined via the American Society for Testing and Materials (ASTM) D4442-92(2003)

209

standard procedure. 39

210

Four sets of tests were conducted with various different configurations presented in

211

Table 1. The first set of tests are performed with both the PA and SA inlet in natural draft

212

configuration. These natural draft tests can be considered as a baseline against which the

213

various alterations of PA and SA flow can be compared. The following sections provide

214

details about the respective variations within each set of tests.

215

2.3.1 Primary Air Testing

216

The PA flow is varied while SA is introduced through natural draft. The PA flow rates

217

are 78, 98, 118 and 138 L·min−1 , corresponding to 47.0, 59.0, 71.0 and 83.2 g·m−2 ·s−1

218

respectively. The flow rates are reported at STP conditions, namely 0°C and 105 Pa. These

219

values were chosen in accordance with previous studies on fixed bed reactors and provide

220

an oxygen-limited environment for the migrating pyrolysis. 16–18,20,21 They are also similar

221

to values and extending the range of a previous study on a similar combustor. 30

222

2.3.2 Secondary Air Testing

223

For the SA tests, the PA flow was set to a value of 118 L·min−1 , while SA flows of 328, 410,

224

492, and 574 L·min−1 were injected into the combustor extension. No previous studies

225

have been found in which specified flowrates of SA were introduced into a staged com-

226

bustor. Therefore, an approximation was performed based on previous findings. It has

227

been reported that during the migrating pyrolysis the primary air to fuel (A/F) mass ratio

228

settles at about 1.5 for different PA flow rates. 30 From the ultimate analysis a mole fraction

229

of C1.00 H1.45 O0.62 can be derived for the pine chips, with a respective stoichiometric A/F 10

ACS Paragon Plus Environment

Page 10 of 41

Page 11 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

230

mass ratio of 6.2 for complete combustion. Assuming an A/F mass ratio of 1.5 during

231

the migrating pyrolysis 30 the overall fuel equivalence ratio (φ) would be 1.11, 0.94, 0.81

232

and 0.71, for the different SA air flows respectively. Therefore, fuel-rich conditions can be

233

expected for the 328 L·min−1 case but fuel-lean conditions for all other flow rates.

234

2.3.3 Varying Fuel Grate Location Testing

235

The location of the fuel stack within the combustor was varied to change the residence

236

time of the gases within the combustor body. The tests were performed with the fuel grate

237

at a distance of 180 mm, 270 mm, 370 mm and 470 mm below the SA inlet, as presented

238

in Figure 2. The PA flow was set to a constant value 118 L·min−1 and the natural draft

239

combustor extension was attached to the combustor body.

240

2.4

241

To account for dilution and determine a quantitative value for the combustor efficiency,

242

the measured emissions were normalised. This normalisation was performed by relat-

243

ing the measured concentrations to all gaseous carbonaceous combustion products. This

244

include the calculation of the nominal combustion efficiency (NCE = XCO2 /(XCO +XCO2 )

245

where X is mole fraction), which has previously been established for the evaluation of

246

cookstoves. 40 The only gaseous carbonaceous species that were considered in the nor-

247

malisation were CO and CO2 , as the hydrocarbon emissions were below the detection

248

limit.

Data Processing

249

The three expected phases of operation are (1) the lighting phase, (2) the steady-state

250

phase and (3) the char phase. Rigorous analysis identified that all three phases could be

251

identified based on the transition between phases. A mathematical decision rule was used

252

to separate the three phases, to be able to analyse each phase separately. When the tem-

253

poral derivative of the normalised CO profile exceeded a value of ±0.002 s−1 a change

254

in phase was identified. This value was established to be a robust identifier of a change 11

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

255

in phase. Figure 3 presents an example emissions profile, divided into the three phases

256

by the mathematical decision rule. For each of the three phases, peak values or time-

257

weighted-average (TWA) values were calculated. In the lighting phase the average of the

258

peak values, over all repeat runs, were calculated because this measure is best suited to

259

the transient processes where peaks occur. For the steady-state phase TWA values provide

260

an average value for the steady emissions. For the char phase, both average peak values

261

and TWA values were calculated to account for multiple emissions peaks experienced in

262

this phase.

263

3 Results

264

3.1

265

Preliminary tests were conducted with the research combustor in its natural draft config-

266

uration. The results from these natural draft conditions are presented within the figures

267

of the results from the other sets of tests such that the natural draft case serves as a refer-

268

ence point. In this way, it is possible to see if changing operating parameters can enhance

269

the performance and mitigate emissions of incomplete combustion.

Natural Draft

270

The natural draft tests were used to identify the different combustion phases, the light-

271

ing phase, the steady-state phase and the char phase (as previously described in detail 41 ).

272

In the lighting phase the kindling material is lit on top of the fuel stack leading to the

273

combustion of the top layer of the solid biomass fuel. In this phase, high emissions of

274

incomplete combustion, namely CO and H2 , were detected, as can be seen in Figure 4. In

275

the steady-state phase the nominal combustion efficiency (NCE) is very high, accompa-

276

nied by low emission of products of incomplete combustion. In the char phase the NCE

277

decreases significantly and the emissions of CO rise.

12

ACS Paragon Plus Environment

Page 12 of 41

Page 13 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

278

3.2

Variation of Primary Air

279

The emissions and gas-phase temperature profiles with varying PA flows and natural

280

draft SA flow are presented in Figure 4. As explained previously, the three combustion

281

processes of lighting in the first 76 to 102 s, the steady-state combustion in the following

282

178 to 281 s and after that the char gasification were identified. For the measured emis-

283

sions, average peak values were calculated for the lighting phase and time weight aver-

284

age values were calculated for the steady-state as well as the char phase, as presented in

285

Table 2.

286

It can be seen in Figure 4 that in the lighting phase the normalised peak NCE and the

287

measured gas-phase temperature inside the combustor body rise while the normalised

288

H2 emissions subside substantially with an increase in PA flow. This is consistent with a

289

previous study, 10 which also showed that higher air flows lead to a higher rate of com-

290

bustion. In the natural draft case, the emissions of products of incomplete combustion

291

are much higher than those in all the forced air cases, except the 78 L·min−1 case. To start

292

the process the fuel is placed inside the combustor body and lit from the top. The initial

293

combustion of kindling material and the top layer of biomass consumes the surrounding

294

oxygen inside the combustor body. In the forced draft cases the airflow through the fuel

295

bed provides the necessary oxygen for further combustion, while in the natural draft case

296

the flow has to be established by the buoyancy force. Thus to start a flow through the fuel

297

stack the buoyancy force has to exceed the pressure drop imposed by the fuel stack. This

298

pressure drop could lead to a lower PA flow in the beginning causing the high emissions

299

in the lighting phase. A comparison of the natural draft and varying primary air test

300

results suggest that the average natural draft flow rate is close to 98 L·min−1 .

301

Increasing the PA leads to a higher fuel conversion and a shorter time in the steady-

302

state phase. This is supported by the increase of TWA NCE values up to 0.9968 while the

303

time in this phase as well as normalised H2 emissions decrease to 0.00005, as presented

304

in Table 2. The gas-phase temperature profiles increase slightly with the PA, compared 13

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

305

to the natural draft case, except for the case of 118 L·min−1 in which the temperatures

306

exceed all other measurements by approximately 150°C. This increase in temperature is

307

related to the higher fuel conversion and the decrease of emissions of incomplete com-

308

bustion, which will lead to a greater heat release in the system. Further addition of air

309

leads to cooling due to air dilution.

310

As shown in Table 2, the TWA NCE values decrease from 0.9271 to 0.7773 in the char

311

phase with higher PA flows. It is hypothesised that with a higher air flow the products of

312

the gasification process, mainly CO, are not subsequently burned in flaming combustion

313

on top of the fuel stack. The flames observed on top of the fuel stack in the gasification

314

phase consume a higher proportion of the CO emissions in the natural draft case than

315

with higher primary air flows. The higher flow rates appear to allow insufficient resi-

316

dence time for complete oxidation within the flaming region. This is supported by the

317

gas-phase temperature profiles inside the combustor body. Temperatures increase with

318

higher forced PA flow, but are consistently much lower than in the natural draft case.

319

In addition, it can be assumed that the higher velocity of the migrating pyrolysis front,

320

with higher PA flow, results in a higher initial heating rate of the solid fuel. 20 The initial

321

heating rate has been shown to be decisive for the reactivity of the char. 42,43 Therefore,

322

the high CO emissions especially at the beginning of the char phase could be caused by a

323

higher reactivity of the remaining char after the steady-state phase.

324

3.3

325

Figure 5 presents the normalised emissions and temperature profiles with varying sec-

326

ondary air as well as the natural draft case. It can be seen that in all phases the emissions

327

are reduced substantially and the NCE is, except for the lowest value of SA, consistently

328

higher than in the natural draft case. The initial peak of emissions in the lighting phase is

329

reduced and the gas-phase temperatures inside the combustor body rise significantly.

330

Variation of Secondary Air

In the steady-state phase it can be seen that the flow rate of 328 L·min−1 leads to 14

ACS Paragon Plus Environment

Page 14 of 41

Page 15 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

331

higher emissions than all the other cases, including the natural draft case. Thus, it can

332

be assumed that a flow rate of 328 L·min−1 provides, as expected from the calculations

333

presented in the Section 2.3.2, fuel-rich conditions and insufficient oxygen for complete

334

combustion of the pyrolysis products. The NCE is consistently higher for all other air

335

flows, compared to the natural draft case. In accordance, the gas-phase temperature in-

336

side the combustor extension is consistently higher. It should be highlighted that with the

337

forced secondary air flows of 492 L·min−1 and 574 L·min−1 up to approximately 300°C

338

higher temperatures can be measured.

339

In the char phase the reduction of emissions is especially significant, in relation to the

340

natural draft case. The TWA NCE, as presented in Table 2, rises for all flow rates above

341

0.92 and up to 0.96 while the normalised H2 value sinks as low as 0.00003. Values of

342

such high efficiency had previously not been achieved in the char phase. This indicates

343

that with higher secondary air flow rates a significantly greater proportion of CO emis-

344

sions from the char gasification are oxidised. It should be stressed that only in the case

345

of the two higher air flow rates the gas-phase temperatures inside the combustor body

346

reach temperatures similar to the natural draft case. These high temperatures were only

347

achieved with both airflows in natural draft configuration and with high SA flows, while

348

temperatures with forced PA and natural draft SA were lower. Thus it can be assumed

349

that the higher SA flow rates lead to a higher heat release from combustion in this phase.

350

A noticeable increase in efficiency is noted between the flow rates of 328 and 492 L·min−1 ,

351

but only a slight increase above that. This could mean that increasing the SA flow beyond

352

a specified air to fuel ratio has only a marginal influence on the performance. It can be

353

assumed that an optimal ratio of the PA to SA exists and that for a specific PA flow, lower

354

SA flow values might lead to insufficient mixing of combustible gases with air, while an

355

oversupply might lead to cooling and potentially quenching of the flame front. A ratio

356

of PA to SA flow of about 1:4 appears to achieve a very high combustion efficiency for

357

this configuration. Previously ratios of 1 to 3.1, 5.7, 6.2 28 and 2.3 44 have been reported,

15

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

358

but no relationship to the efficiency was established. Ratios of 1:3 and 1:4 have also been

359

reported to achieve low CO emissions in the steady-state phase, where the char phase has

360

not been considered. 31 Further investigation coupling the combustion efficiency with the

361

heat transfer efficiency would be helpful in finding an optimal PA to SA flow ratio.

362

3.4

363

The normalised emissions and temperature profiles of various fuel grate (FG) locations

364

are presented in Figure 6. It can be seen that a reduction of the fuel stack distance to the

365

SA inlet leads to higher measured temperatures inside the combustor extension ranging

366

from 150°C to 250°C above the natural draft case. The increased temperature, compared

367

to the natural draft case, of about 150°C with a FG distance of 470 mm can be attributed

368

to the supply of forced primary air. The further temperature increase can be assumed to

369

be due to the smaller distances of the FG. With a smaller distance between the fuel and

370

the SA inlet there will be less heat loss of the gasification products before combustion,

371

leading to an increase in the combustion temperature and thus efficiency. The higher

372

temperatures will cause a greater buoyancy force at the SA inlet, increasing the amount

373

of entering air, which in turn will effect the combustion efficiency. Decreasing emissions

374

of products of incomplete combustion were recorded in the lighting and char phase, with

375

smaller distances of the FG. Fuel grate locations of 180 and 270 mm provided NCE values

376

of 0.9988 in the lighting phase, which were the highest of all measured configurations. A

377

smaller distance of the fuel grate location also prolonged the high efficiency steady-state

378

phase significantly, with a minor reduction of the NCE. In the char phase smaller distance

379

of the FG caused a higher NCE, but only the lowest distance of 180 mm achieved a higher

380

NCE than the natural draft configuration.

Variation of the Fuel Grate Location

16

ACS Paragon Plus Environment

Page 16 of 41

Page 17 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

381

4 Discussion

382

Comparing the profiles, presented in Figures 4 and 5, it needs to be kept in mind that

383

in the set of varying SA flow rates the PA was fixed to the value of 118 L·min−1 and the

384

fuel grate location was at 470 mm below the SA inlet. Of special interest when relating

385

these profiles to one another is that with higher SA flows the steady-state is longer and

386

the emissions of incomplete combustion in the char phase are extensively mitigated, as

387

can be seen in Table 2.

388

It has been established that the migrating pyrolysis is primarily governed by the PA

389

flow. 12 Direct influence of the SA on the fuel stack is highly unlikely even at the highest

390

air flows because of the large distance between the SA inlet and the fuel stack. This

391

leads to the assertion that with a specified PA flow the migrating pyrolysis is of similar

392

intensity and length. This raises the question how the introduction of forced SA prolongs

393

the steady-state phase. From the temperature profiles and the NCE profiles in Figure 4

394

it can be deduced that the flame front at the SA inlet cannot be sustained at the end of

395

the migrating pyrolysis, it extinguishes and subsequently high proportions of CO are

396

emitted, in the configuration in which the SA is introduced by natural draft. In the forced

397

SA cases, if the migrating pyrolysis is assumed to be of similar length as in the natural

398

draft SA and 118 L·min−1 PA configuration, the flame does not extinguish at the end of

399

this phase. With a flame present at the SA inlet the CO emissions which were emitted in

400

the natural draft SA case are oxidised further. Therefore, it appears that with forced SA

401

flow sufficient mixing of entering air and combustible gases, in conjunction with much

402

higher temperatures in the combustor extension, can be achieved to sustain a flame at the

403

SA inlet. With a flame present at the SA inlet a greater part of the CO emissions produced

404

by the gasification process of char are burned in steady-state combustion, as can be seen in

405

Figure 5. The combustion of CO from char gasification with increased secondary air at the

406

secondary air inlet presents an extension of the steady-state combustion at this location,

407

which was previously achieve only during the migrating pyrolysis. 17

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

408

A similar trend as with higher SA flows can be observed with smaller distances of

409

the FG in the steady-state phase. The steady-state phase lasts much longer, for 419 s,

410

with the lowest distance of the FG, compared to 179 s with the greatest distance. Simi-

411

lar to the forced SA air cases much higher gas-phase temperatures were also measured

412

in the combustor extension. In Figure 6 it can be seen that the measured gas tempera-

413

ture inside the combustor extension is approximately 100°C higher with a FG distance

414

of 180 mm compared with 470 mm. When the gas temperature is higher there is an in-

415

crease in buoyancy-induced flow due to the greater density difference between the gases

416

inside the combustor extension and the cold secondary air. Accordingly, the higher air

417

flow, with smaller distance of the FG, in conjunction with the higher temperatures appear

418

to keep a flame present at the SA inlet during the combustion of gasification products

419

from mainly raw biomass and into the combustion of mainly CO from char gasification.

420

This extension of the steady-state combustion, to include combustion of char gasification

421

products, seems to be the reason for a longer duration of this phase and a reduction of

422

overall CO emissions.

423

In the char phase the reduction of emissions, especially CO, with the higher SA flow,

424

is a result of a combination of the longer steady-state phase and the influence of the SA

425

on the air flow inside the combustor body. A higher efficiency and the combustion of

426

char gasification products at the end of the steady-state phase, will lead to a much lower

427

amount of char remaining after this phase. The lower amount of remaining char alone

428

cannot explain the much higher NCE in the char phase with increasing SA flow. There-

429

fore, the SA must also have an influence on the flow field inside the combustor body. The

430

increasing amount of forced SA being introduced will lead to better mixing and more

431

complete combustion in the secondary flame front. Future studies of the influence of SA

432

on the flow field inside staged combustors could provide deeper insights.

433

The direct application of the current findings in cookstoves is primarily limited by the

434

chosen research approach, which is focussed specifically on the combustion science of the

18

ACS Paragon Plus Environment

Page 18 of 41

Page 19 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

435

thermochemical process. In this study measurements were carried out without emulating

436

user practice or performing cooking tasks. Therefore, the influence of a cooking pot on top

437

of the stove on the combustion performance is unknown. Similarly, with a smaller diam-

438

eter reactor the influence of quenching by the cold walls may become more pronounced.

439

In an optimised system, it is aspirational for combustion to be completed before contact

440

with the cooking surface or walls. The heat transfer to the pot would then be exclusively

441

achieved by hot flue gases. Hence, in such a system the combustion properties would be

442

independent of the cooking performance. To achieve such a system, further fundamen-

443

tal research on the gasification and combustion behaviour of staged combustors, using

444

different fuels and air supply conditions as well as the heat transfer properties would be

445

beneficial.

446

5 Conclusions

447

The present study investigates the influence of the primary and secondary air, with nat-

448

ural draft as well as forced draft, in various relations to each other, on the combustion

449

process in a staged combustor. The location of fuel within the combustor was modified to

450

simulate the variation of the relative position of the primary and secondary air inlet to the

451

fuel stack. This study presents general insights into the combustion processes in small-

452

scale staged combustion devices. The combustor used for this research was custom made

453

for the purpose of studying the ongoing combustion processes and is not being used for

454

cooking, which limits the comparability to commercial products which are usually tested

455

while performing certain cooking tasks.

456

In the lighting phase, emissions of incomplete combustion can be significantly reduced

457

by providing a sufficient air supply. This can be achieved by either ensuring that the top of

458

the fuel stack is always as close as possible to the secondary air (SA) inlet, which achieves

459

highest efficiency, or by introducing SA by forced draft. When using forced draft the peak

19

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

460

NCE rises by increasing the primary air (PA) air flow, from 0.84 with natural draft up to

461

0.96, but even more so by increasing the SA flow, up to 0.99.

462

The migrating pyrolysis is governed by the PA flow with higher flows increasing the

463

heat release. During the migrating pyrolysis the products are oxidised in steady-state

464

combustion at the secondary air inlet. When using a combination of forced PA supply and

465

natural draft SA, an increase of PA leads to a shorter time in this steady-state phase with

466

higher combustion temperatures and a higher NCE. Introducing forced SA in combina-

467

tion with forced PA leads to longer steady-state combustion, extending it from primarily

468

combustion of volatile pyrolysis products to combustion of primarily carbon monoxide

469

from char gasification. This provides a drastic reduction of products of incomplete com-

470

bustion and a significant increase in efficiency. A considerable increase in combustion

471

efficiency was identified for PA to SA flow ratios of up to 1:4, for the wood chips fuel.

472

Reducing the distance between the SA inlet and the fuel stack, with SA introduced by

473

natural draft, had a similar effect to increasing the SA via forced draft. Therefore, an ad-

474

justable fuel grate, to be able to use a variable amount fuel without increasing the release

475

of emissions of incomplete combustion, should be considered for any staged combustor

476

design. Future work including the influence of the fuel stack depth on the combustion

477

process would be beneficial.

478

In the char phase, increasing the PA flow produced significantly more emissions of

479

incomplete combustion. With the addition of an increased amount of forced SA these

480

emissions could be burned cleanly.

481

In the present study different air requirements for the three phases lighting, steady-

482

state and char, have been identified. The application of dynamic air control, rather than a

483

constant air supply, to suit each phase could be the topic of future research. Furthermore,

484

it could be shown that forced PA in combination with natural draft SA is not a beneficial

485

option. To achieve low emissions in this configuration it would require attentive handling

486

to reduce the PA flow after the steady-state phase. Forced draft for the PA as well as SA

20

ACS Paragon Plus Environment

Page 20 of 41

Page 21 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

487

flow to increases the controllability and efficiency in all phases. To achieve low emissions

488

of incomplete combustion, fuel-lean conditions must be ensured in the secondary flame

489

front. The combustion efficiency is also greater with a smaller distance between the fuel

490

and the SA inlet.

491

6 Acknowledgements

492

The authors wish to acknowledge the support of The University of Adelaide and Marc

493

Simpson, the laboratory facilities manager. The contributions to the provision and anal-

494

ysis of the experiments by Aleksis Xenophon, James Metcalfe and Oliver Robson are

495

greatly appreciated. Thomas Kirch gratefully acknowledges the support provided by the

496

Studienstiftung des Deutschen Volkes.

21

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Figure 1: Schematic illustration of the combustion process in a staged combustor.

22

ACS Paragon Plus Environment

Page 22 of 41

Page 23 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Figure 2: Schematic diagram of the combustor, with inlet locations for thermocouples (A, B) and measuring location of the outer combustor body temperature (C), with the air flow direction and all numeric values in millimetres.

23

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Lighting

Page 24 of 41

Char

Steady-state

Figure 3: Normalised CO emissions profile with separated phases by the mathematical decision rule. Phase change was identified when the temporal derivative of the normalised CO profile (XCO /(XCO +XCO2 )) exceeded a value of ±0.002 s−1 .

24

ACS Paragon Plus Environment

0.08

0.9

0.06

Normalised H2

1

0.8 0.7 0.6

0

200

400

0.02 0

600

800 600 400 200 0

0.04

Body Temperature (°C)

Extension Temperature (°C)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

NCE

Page 25 of 41

0

200

400

600

0

200

400

600

0

200

400

600

800 600 400 200 0

Time (s) 78 L/min

Time (s) 98 L/min

118 L/min

138 L/min

Natural draft

Figure 4: Average normalised emissions profiles of H2 , the nominal combustion efficiency (NCE = XCO2 /(XCO +XCO2 )) and measured gas-phase temperature profiles, inside the combustor body and the combustor extension, for various primary air flows, and the natural draft case.

25

ACS Paragon Plus Environment

Energy & Fuels

0.04

Normalised H2

1

NCE

0.9

0.8

0

200

400

800 600 400 200 0

0

200

400

0.03 0.02 0.01 0

600

Body Temperature (°C)

0.7

Extension Temperature (°C)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 26 of 41

600

0

200

400

600

0

200

400

600

800 600 400 200 0

Time (s) 328 L/min

410 L/min

Time (s) 492 L/min

574 L/min

Natural draft

Figure 5: Average normalised emissions profiles of H2 , the nominal combustion efficiency (NCE = XCO2 /(XCO +XCO2 )) and measured gas-phase temperature profiles, inside the combustor body and the combustor extension, for various secondary air flows, at 118 L·min−1 primary air flow, and the natural draft case.

26

ACS Paragon Plus Environment

Page 27 of 41

1

Normalised H2

0.08

NCE

0.9 0.8 0.7 0.6

0

200

400

0.06 0.04 0.02 0

600

0

200

Time (s) Extension Temperature (°C)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

400

600

Time (s)

800 600 400 200 0

0

100

200

300

400

500

600

Time (s) 180 mm

270 mm

370 mm

470 mm

Natural draft (470 mm)

Figure 6: Average normalised emissions profiles of H2 , the nominal combustion efficiency (NCE = XCO2 /(XCO +XCO2 )) and measured gas-phase temperature profiles, inside the combustor extension, for varying distances of the fuel grate below the SA inlet, at 118 L·min−1 primary air flow, and the natural draft case.

27

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 28 of 41

Table 1: Configurations of the natural draft (ND), varying primary air (PA), varying secondary air (SA) and varying fuel grate locations (FGL) below the SA inlet cases that were tested. Both Natural draft Varying primary air

Varying secondary air

Varying fuel grate location

Repetitions 8 5 4 6 6 4 3 3 3 4 3 3 6

PA flow[L min−1 ] ND 78 98 118 138 118 118 118 118 118 118 118 118

28

SA flow[L min−1 ] ND ND ND ND ND 328 410 492 574 ND ND ND ND

ACS Paragon Plus Environment

FGL [mm] 470 470 470 470 470 470 470 470 470 180 270 370 470

Equivalence Ratio (Φ)

1.11 0.94 0.81 0.71

Page 29 of 41

Table 2: Average peak emissions in the lighting phase and time weight average (TWA) emissions in the steady-state and the char phase for all four investigated cases, with the standard deviation in parenthesis. Natural draft

Min NCE Max H2 Peak

Time in Phase TWA - NCE TWA - H2

TWA - NCE TWA - H2

0.8404 (0.1659) 0.0418 (0.0538) 285.4 (27.7) 0.9965 (0.0006) 0.00013 (0.00015) 0.8518 (0.0428) 0.01368 (0.00727)

Varying primary air [L·min−1 ] 78 98 118 138 Lighting phase 0.6155 0.8639 0.8266 0.9631 (0.1424) (0.1233) (0.1597) (0.0124) 0.1044 0.0314 0.0447 0.0043 (0.0513) (0.0352) (0.0466) (0.0027) Steady-state phase 281.4 224.5 178.8 213.7 (121.3) (67.7) (19.8) (21.6) 0.9931 0.9963 0.9970 0.9968 (0.0024) (0.0008) (0.0007) (0.0008) 0.00049 0.00021 0.0003 0.00005 (0.0004) (0.00017) (0.00024) (0.00005) Char phase 0.9271 0.8912 0.8303 0.7773 (0.0348) (0.0532) (0.0182) (0.0225) 0.01667 0.01026 0.01679 0.01343 (0.00286) (0.00516) (0.00396) (0.01008)

Varying secondary air [L·min−1 ] 328 410 492 574 Lighting phase 0.9851 0.9868 0.9889 0.9920 (0.0045) (0.0004) (0.0012) (0.0019) 0.0007 0.001 0.00105 0.00023 (0.0007) (0.0005) (0.0009) (0.0004) Steady-state phase 275.7 263.0 279.3 242.7 (20.6) (30.2) (15.0) (29.5) 0.9938 0.9977 0.9989 0.9991 (0.0016) (0.0018) (0.0004) (0.0003) 0.0003 0.00013 0.00006 0.00001 (0.00008) (0.00021) (0.00006) (0.00001) Char phase 0.9277 0.9549 0.9590 0.9600 (0.0356) (0.0165) (0.0156) (0.0026) 0.00277 0.00078 0.00135 0.00003 (0.00073) (0.00145) (0.00003) (0.00384)

29

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47

Energy & Fuels

ACS Paragon Plus Environment

Varying fuel grate location [mm] 270 370 470 Lighting phase 0.9988 0.9988 0.9785 0.8267 (0.0005) (0.0011) (0.0029) (0.1597) 0.0 0.00047 0.00179 0.0447 (0.00000) (0.00082) (0.00057) (0.04656) Steady-state phase 419.25 398.0 258.3 178.8 (29.3) (25.0) (17.0) (19.7) 0.9951 0.9966 0.9970 0.9970 (0.0016) (0.0002) (0.0004) (0.0007) 0.00013 0.00020 0.00002 0.0003 (0.00014) (0.0002) (0.00001) (0.00024) Char phase 0.9089 0.8340 0.7788 0.8303 (0.0105) (0.0084) (0.0156) (0.0182) 0.00645 0.01536 0.01207 0.01679 (0.00397) (0.00174) (0.00516) (0.00284) 180

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

497

7 References

498

References

499

¨ ¨ A.; (1) Bonjour, S.; Adair-Rohani, H.; Wolf, J.; Bruce, N. G.; Mehta, S.; Pruss-Ust un,

500

Lahiff, M.; Rehfuess, E. A.; Mishra, V.; Smith, K. R. Solid fuel use for household cook-

501

ing: Country and regional estimates for 1980-2010. Environmental Health Perspectives

502

2013, 121, 784–790.

503

(2) Lelieveld, J.; Evans, J. S.; Fnais, M.; Giannadaki, D.; Pozzer, a. The contribution of

504

outdoor air pollution sources to premature mortality on a global scale. Nature 2015,

505

525, 367–71.

506

(3) Murray, C. J. L.; Forouzanfar, M. H.; Alexander, L.; Anderson, H. R.; Bachman, V. F.

507

Global, regional and national comparative risk assessment of 79 behavioural, en-

508

vironmental/occupational and metabolic risks or clusters of risks in 188 countries

509

1990-2013: a systematic analysis for the Global Burden of Disease Study 2013. Lancet

510

in print 2015, 6736, 1998–2005.

511

512

(4) Sovacool, B. K. The political economy of energy poverty: A review of key challenges. Energy for Sustainable Development 2012, 16, 272–282.

513

(5) Anenberg, S. C.; Balakrishnan, K.; Jetter, J.; Masera, O.; Mehta, S.; Moss, J.; Ra-

514

manathan, V. Cleaner cooking solutions to achieve health, climate, and economic

515

cobenefits. Environmental Science and Technology 2013, 47, 3944–3952.

516

(6) Jetter, J.; Zhao, Y.; Smith, K. R.; Khan, B.; Yelverton, T.; DeCarlo, P.; Hays, M. D.

517

Pollutant emissions and energy efficiency under controlled conditions for household

518

biomass cookstoves and implications for metrics useful in setting international test

519

standards. Environmental Science and Technology 2012, 46, 10827–10834.

30

ACS Paragon Plus Environment

Page 30 of 41

Page 31 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

520

521

Energy & Fuels

(7) Jetter, J. J.; Kariher, P. Solid-fuel household cook stoves: Characterization of performance and emissions. Biomass and Bioenergy 2009, 33, 294–305.

522

(8) Houshfar, E.; Skreiberg, Ø.; Løv˚as, T.; Todorovi´c, D.; Sørum, L. Effect of excess air

523

ratio and temperature on NOx emission from grate combustion of biomass in the

524

staged air combustion scenario. Energy and Fuels 2011, 25, 4643–4654.

525

526

(9) Reed, T. B.; Larson, R. A wood-gas stove for developing countries. Energy for Sustainable Development 1996, 3, 34–37.

527

(10) Arora, P.; Das, P.; Jain, S.; Kishore, V. V. N. A laboratory based comparative study of

528

Indian biomass cookstove testing protocol and Water Boiling Test. Energy for Sustain-

529

able Development 2014, 21, 81–88.

530

(11) Roth, C. Micro-gasification : cooking with gas from dry biomass. GIZ - Deutsche

531

Gesellschaft fuer Internationale Zusammenarbeit, 2014;

532

fachexpertise/downloads/giz2014-en-micro-gasification-manual-hera.pdf.

http://www.giz.de/

533

(12) Reed, T.; Walt, R.; Ellis, S.; Das, A.; Deutch, S. Superficial Velocity - The Key To

534

Downdraft Gasification. 4th Biomass Conference of the Americas. Oakland, Califor-

535

nia, 1999; pp 1–8.

536

(13) Yibo, H.; Li, H.; Chen, X.; Xue, C.; Chen, C.; Liu, G. Effects of moisture content in fuel

537

on thermal performance and emission of biomass semi-gasified cookstove. Energy for

538

Sustainable Development 2014, 21, 60–65.

539

540

(14) Branca, C.; Di Blasi, C. Global Kinetics of Wood Char Devolatilization and Combustion. Energy and Fuels 2003, 17, 1609–1615.

541

(15) Birzer, C.; Medwell, P.; MacFarlane, G.; Read, M.; Wilkey, J.; Higgins, M.; West, T. A

542

Biochar-producing, Dung-burning Cookstove for Humanitarian Purposes. Procedia

543

Engineering 2014, 78, 243–249. 31

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

544

545

(16) Fatehi, M.; Kaviany, M. Adiabatic reverse combustion in a packed bed. Combustion and Flame 1994, 99, 1–17.

546

¨ (17) Ronnb¨ ack, M.; Axell, M.; Gustavsson, L.; Thunman, H.; Lecher, B. In Progress in Ther-

547

mochemical Biomass Conversion; Bridgwater, A., Ed.; Blackwell Science Ltd: Bodmin,

548

2001; Chapter 59, pp 743–757.

549

(18) Horttanainen, M.; Saastamoinen, J.; Sarkomaa, P. Operational limits of ignition front

550

propagation against airflow in packed beds of different wood fuels. Energy and Fuels

551

2002, 16, 676–686.

552

(19) Yang, Y. B.; Sharifi, V. N.; Swithenbank, J. Effect of air flow rate and fuel moisture on

553

the burning behaviours of biomass and simulated municipal solid wastes in packed

554

beds. Fuel 2004, 83, 1553–1562.

555

˜ D.; Collazo, J.; Granada, E.; Moran, J.; Miguez, J. L. Experimental (20) Porteiro, J.; Patino,

556

analysis of the ignition front propagation of several biomass fuels in a fixed-bed

557

combustor. Fuel 2010, 89, 26–35.

558

˜ D.; Moran, J.; Granada, E. Study of a fixed-bed biomass combus(21) Porteiro, J.; Patino,

559

tor: Influential parameters on ignition front propagation using parametric analysis.

560

Energy and Fuels 2010, 24, 3890–3897.

561

(22) Buchmayr, M.; Gruber, J.; Hargassner, M.; Hochenauer, C. Experimental investiga-

562

tion of the primary combustion zone during staged combustion of wood-chips in a

563

commercial small-scale boiler. Biomass and Bioenergy 2015, 81, 356–363.

564

565

566

(23) Kuo, J. T.; Hsu, W.-S.; Yo, T.-C. Effect of Air Distribution on Solid Fuel Bed Combustion. Journal of Energy Resources Technology 1997, 119, 120. (24) MacCarty, N.; Still, D.; Ogle, D. Fuel use and emissions performance of fifty cooking

32

ACS Paragon Plus Environment

Page 32 of 41

Page 33 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

567

stoves in the laboratory and related benchmarks of performance. Energy for Sustain-

568

able Development 2010, 14, 161–171.

569

570

(25) Aprovecho Research Center, Test Results of Cook Stove Performance. 2011; http: //aprovecho.org/publications-3/.

571

(26) Kumar, M.; Kumar, S.; Tyagi, S. Design, development and technological advance-

572

ment in the biomass cookstoves: A review. Renewable and Sustainable Energy Reviews

573

2013, 26, 265–285.

574

(27) Kshirsagar, M. P.; Kalamkar, V. R. A comprehensive review on biomass cookstoves

575

and a systematic approach for modern cookstove design. Renewable and Sustainable

576

Energy Reviews 2014, 30, 580–603.

577

578

(28) Reed, T. B.; Anselmo, E.; Kircher, K. In Progresss in Thermochemical Biomass Conversion Conference; Bridgwater, A., Ed.; Blackwell Science Ltd: Bodmin, 2001; pp 693 – 704.

579

(29) Mukunda, H. S.; Dasappa, S.; Paul, P. J.; Rajan, N. K. S.; Yagnaraman, M.; Ravi Ku-

580

mar, D.; Deogaonkar, M. Gasifier stoves - science, technology and field outreach.

581

Current Science 2010, 98, 627–638.

582

(30) Varunkumar, S.; Rajan, N. K. S.; Mukunda, H. S. Experimental and computational

583

studies on a gasifier based stove. Energy Conversion and Management 2012, 53, 135–

584

141.

585

(31) Tryner, J.; Tillotson, J. W.; Baumgardner, M. E.; Mohr, J. T.; Defoort, M. W.; March-

586

ese, A. J. The effects of fuel properties , air flow rates , secondary air inlet geometry ,

587

and operating mode on the performance of TLUD semi-gasifier cookstoves. Environ-

588

mental Science and Technology 2016,

589

(32) Kirch, T.; Medwell, P. R.; Birzer, C. H. Natural draft and forced primary air combus-

33

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

590

tion properties of a top-lit up-draft research furnace. Biomass and Bioenergy 2016, 91,

591

108–115.

592

593

¨ (33) Eskilsson, D.; Ronnb¨ ack, M.; Samuelsson, J.; Tullin, C. Optimisation of efficiency and emissions in pellet burners. Biomass and Bioenergy 2004, 27, 541–546.

594

(34) Carroll, J. P.; Finnan, J. M.; Biedermann, F.; Brunner, T.; Obernberger, I. Air staging

595

to reduce emissions from energy crop combustion in small scale applications. Fuel

596

2015, 155, 37–43.

597

(35) Lombardi, F.; Riva, F.; Bonamini, G.; Barbieri, J. Laboratory protocols for testing of

598

Improved Cooking Stoves ( ICSs ): A review of state-of-the-art and further develop-

599

ments. Biomass and Bioenergy 2017, 98, 321–335.

600

(36) Birzer, C.; Medwell, P.; Wilkey, J.; West, T.; Higgins, M.; Macfarlane, G.; Read, M.

601

An analysis of combustion from a top-lit up-draft ( TLUD ) cookstove. Journal of

602

Humanitarian Engineering 2013, 2, 1–8.

603

604

605

606

(37) Kirch, T.; Medwell, P. R.; Birzer, C.; Holden, L. The role fo primary and secondary air on wood combustion in cookstoves. International Journal of Sustainable Energy 2016, (38) Yevich, R.; Logan, J. A. An assessment of biofuel use and burning of agricultural waste in the developing world. Global Biogeochemical Cycles 2003, 17.

607

(39) American Society for Testing and Materials, ASTM D4442-92(2003): Standard Test

608

Methods for Direct Moisture Content Measurement of Wood and Wood-based Ma-

609

terials. 2003.

610

(40) Johnson, M.; Edwards, R.; Berrueta, V.; Masera, O. New approaches to performance

611

testing of improved cookstoves. Environmental Science and Technology 2010, 44, 368–

612

374.

34

ACS Paragon Plus Environment

Page 34 of 41

Page 35 of 41 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

613

(41) Kirch, T.; Medwell, P. R.; Birzer, C. H. Assessment of natural draft combustion prop-

614

erties of top-lit up-draft research furnace. Australian Combustion Symposium 2015

615

Proceedings. Melbourne, 2015.

616

(42) Janse, A. M. C.; Jonge, H. G. D.; Prins, W.; Swaaij, W. P. M. V. Combustion Kinetics

617

of Char Obtained by Flash Pyrolysis of Pine Wood. Ind. Eng. Chem. Res. 1998, 37,

618

3909–3918.

619

(43) Dall’Ora, M.; Jensen, P. A.; Jensen, A. D. Suspension combustion of wood: Influence

620

of pyrolysis conditions on char yield, morphology, and reactivity. Energy and Fuels

621

2008, 22, 2955–2962.

622

(44) Raman, P.; Ram, N. K.; Gupta, R. Development, design and performance analysis of

623

a forced draft clean combustion cookstove powered by a thermo electric generator

624

with multi-utility options. Energy 2014, 69, 813–825.

35

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39

ACS Paragon Plus Environment

Page 36 of 41

Page 37 of 41

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Paragon Plus Environment

Energy & Fuels 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23

Lighting

Steady-state

ACS Paragon Plus Environment

Page 38 of 41

Char

Energy & Fuels

0.08

0.9

0.06

Normalised H2

1

0.8 0.7 0.6

0

200

400

0.02 0

600

800 600 400 200 0

0.04

Body Temperature (°C)

Extension Temperature (°C)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31

NCE

Page 39 of 41

0

200

400

Time (s) 78 L/min

600

0

200

400

600

0

200

400

600

800 600 400 200 0

ACS Paragon Plus Environment

98 L/min

118 L/min

Time (s)

138 L/min

Natural draft

Energy & Fuels

NCE

0.9

0.8

0

200

400

800 600 400 200 0

0

200

400

Time (s) 328 L/min

600

0.03 0.02 0.01 0

600

Body Temperature (°C)

0.7

Extension Temperature (°C)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

Page 40 of 41

0.04

Normalised H2

1

0

200

400

600

0

200

400

600

800 600 400 200 0

ACS Paragon Plus Environment

410 L/min

492 L/min

Time (s) 574 L/min

Natural draft

Page 41 of 411

Normalised H2

NCE

0.9 0.8 0.7 0.6

0

200

400

0.06 0.04 0.02 0

600

0

200

Time (s) Extension Temperature (°C)

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

0.08 Energy & Fuels

400

600

Time (s)

800 600 400 200 0

0

100

200

300

400

500

600

ACS Paragon Plus Environment

Time (s)

180 mm

270 mm

370 mm

470 mm

Natural draft (470 mm)