Subscriber access provided by Fudan University
Article
Inter-laboratory reproducibility of a targeted metabolomics platform for analysis of human serum and plasma Alexandros P. Siskos, Pooja Jain, Werner Römisch-Margl, Mark Bennett, David Achaintre, Yasmin Asad, Luke C. Marney, Larissa Richardson, Albert Koulman, Julian Leether Griffin, Florence I Raynaud, Augustin Scalbert, Jerzy Adamski, Cornelia Prehn, and Hector Charles Keun Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.6b02930 • Publication Date (Web): 30 Nov 2016 Downloaded from http://pubs.acs.org on November 30, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 22
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
Inter-laboratory reproducibility of a targeted metabolomics platform for analysis of human serum and plasma Alexandros P. Siskos,1§ Pooja Jain,1§ Werner Römisch-Margl,2 Mark Bennett,3 David Achaintre,4 Yasmin Asad,5 Luke Marney,6 Larissa Richardson,6 Albert Koulman,6 Julian L. Griffin,6 Florence Raynaud,5 Augustin Scalbert,4 Jerzy Adamski,7,8,9 Cornelia Prehn,7 Hector C. Keun1* 1
Department of Surgery and Cancer, Imperial College London, W12 0NN, UK, Institute of Bioinformatics and Systems Biology, Helmholtz Zentrum München, German Research Center for Environmental Health, 85764 Neuherberg, Germany 3 Department of Life Sciences, Imperial College London, SW7 2AZ, UK 4 International Agency for Research on Cancer (IARC), Biomarkers Group, F-69372 Lyon, France, 5 The Institute of Cancer Research, ICR, Sutton, SM2 5NG, UK, 6 MRC Human Nutrition Research, Cambridge, CB1 9NL, UK, 7 Genome Analysis Center, Institute of Experimental Genetics, Helmholtz Zentrum München, German Research Center for Environmental Health, 85764 Neuherberg, Germany 8 Chair of Experimental Genetics, Center of Life and Food Sciences Weihenstephan, Technische Universität München, 85354 Freising-Weihenstephan, Germany 9 German Center for Diabetes Research (DZD), 85764 Neuherberg, Germany § These authors contributed equally *Corresponding author. Hector C. Keun, e-mail:
[email protected] 2
Abstract A critical question facing the field of metabolomics is whether data obtained from different centres can be effectively compared and combined. An important aspect of this is the inter-laboratory precision (reproducibility) of the analytical protocols used. We analysed human samples in six laboratories using different instrumentation but a common protocol (the AbsoluteIDQTM p180 Kit) for the measurement of 189 metabolites via liquid chromatography (LC) or flow-injection analysis (FIA) coupled to tandem mass spectrometry (MS/MS). In spiked quality control (QC) samples 82% metabolite measurements had an inter-laboratory precision of