Luminescent Iridium(III) Chemosensor for Tandem Detection of F– and

Dec 21, 2017 - A new highly sensitive luminescent iridium(III) chemosensor, 1, was designed and synthesized for tandem detection of fluoride ions (Fâ€...
8 downloads 14 Views 3MB Size
This is an open access article published under an ACS AuthorChoice License, which permits copying and redistribution of the article or any adaptations for non-commercial purposes.

Article Cite This: ACS Omega 2017, 2, 9150−9155

Luminescent Iridium(III) Chemosensor for Tandem Detection of F− and Al3+ Jin-Biao Liu,†,‡ Wanhe Wang,‡ Guodong Li,§ Rui-Xiang Wang,*,† Chung-Hang Leung,*,§ and Dik-Lung Ma*,‡ †

School of Metallurgical and Chemical Engineering, Jiangxi University of Science and Technology, Ganzhou 341000, China Department of Chemistry, Hong Kong Baptist University, Kowloon Tong, Hong Kong 999077, China § State Key Laboratory of Quality Research in Chinese Medicine, Institute of Chinese Medical Sciences, University of Macau, Macao 999078, China ‡

S Supporting Information *

ABSTRACT: A new highly sensitive luminescent iridium(III) chemosensor, 1, was designed and synthesized for tandem detection of fluoride ions (F−) and aluminum ions (Al3+). This sensor 1 exhibited obvious luminesce quenching by hydrogen bond interactions with F−. In addition, the resulting 1-F complex can be further used to detect Al3+ through a luminesce enhancement. The detection limit (0.02 μM) of 1-F for Al3+ is far lower than the World Health Organization (7.41 μM) limit for drinking water. Importantly, chemosensor 1-F could be used to detect and quantify F− and Al3+ reversibly. This sensor achieved rapid detection of two ions, which relies on only one probe. as an Al3+ chemosensor.24 However, the synthesis of this iridium(III) complex required a relatively complicated synthetic route, resulting in a low yield. Therefore, it is worthwhile to develop transition metal complex chemosensors with a relatively simple synthetic route and high sensitivity for Al3+ detection. Developing methods for detection of two ions by only one probe is meaningful and useful. A tandem F−- and metal ionselective sensor has been reported by scientists. However, there is no investigation found in tandem F−−Al3+ monitoring.25−29 In addition, we recently reported a novel iridium(III)-based probe for the in vitro and in vivo detection of iron(III) and sulfide ions in a switch “on−off−on” mode.30 Herein, we present a novel luminescent iridium(III) complex, 1, containing two 2-phenylbenzimidazole (pbim) C∧N ligands and a dimethylphenanthroline N∧N donor ligand as a tandem F− and Al3+ chemosensor (Scheme 1). The emission parameters of iridium(III) complexes are sensitive to both the surrounding environment and the characteristics of their N∧N and C∧N ligands. Through its imidazole motif, complex 1 serves as a hydrogen bond donor with F−, which can deprotonate the N−H group contributed by the formation of the highly stable HF2− anions. This results in increased photoinduced electron transfer, thereby quenching the emission in the 1-F complex.31 Subsequently, Al3+ can

1. INTRODUCTION Fluoride ions (F−) are important in a number of medical and biological processes. F− plays an essential role in dental health1 and may help in preventing osteoporosis.2 However, overexposure to F− can cause kidney problems and acute gastric disorders.3 Consequently, the detection of F− is an important goal for scientists.4 Meanwhile, the extensive use of aluminum in various industrial activities can cause the release of free aluminum ions (Al3+) into the biosphere. At high concentrations, Al3+ is a neurotoxin and can cause organ damage, Parkinson’s disease, or Alzheimer’s disease.5,6 The World Health Organization has set the permissible level of the Al3+ concentration in drinking water to be 7.41 μM. Traditional instrument-based detection methods for the detection of F− and/or Al3+ (19F NMR analysis for F−7 and absorption spectroscopy8 and inductively coupled plasma mass spectrometry9 for Al3+) require expensive instrumentation and/ or time-consuming sample preparation. 10 Recently, the development of rapid and accurate sensitive probes for the monitoring of F−4 and Al3+ ions has received considerable interest.11 Numerous organic dyes have been reported for Al3+ detection, whereas relatively fewer transition metal complex chemosensors for Al3+ have been described.12−20 Compared with organic dyes, metal complexes are attractive scaffolds for chemosensors owing to their large Stokes shift and long-lived luminescence.21−23 In a preliminary investigation, we have reported a novel iridium(III) complex equipped with ophenolsalicylimine (an Al3+ receptor) in the N∧N donor ligand © 2017 American Chemical Society

Received: October 26, 2017 Accepted: November 24, 2017 Published: December 21, 2017 9150

DOI: 10.1021/acsomega.7b01646 ACS Omega 2017, 2, 9150−9155

Article

ACS Omega Scheme 1. Luminescent Iridium(III) Chemosensor 1 for the Tandem Detection of F− and Al3+ Ions

coordinate to anionic pbim, which results in the change of the metal-to-ligand charge-transfer state of the complex, causing a substantial recovery in the emission of 1.32,33 Therefore, this complex can be used as a luminescent chemosensor in tandem sensing of F− and Al3+.

2. RESULTS AND DISCUSSION 2.1. Optimization of Chemosensors. Previous studies by the Liu group have reported the hydrogen-bonding interaction of iridium(III) complexes containing an imidazole group with F−, causing a significant change in the emissive characteristics of the complex.25 In the present work, four iridium(III) complexes (1−4) with a range of C∧N and N∧N ligands were tested for their capability to be quenched by the F− (Figure 1a). Complexes 1 and 2, both containing imidazole motifs in the C∧N ligands, were significantly quenched by F− (Figures 1b and S5). The slightly weaker quenching response of 2 could possibly be due to its sterically bulky N∧N ligand, which hinders the access of F− to the acidic proton. On the other hand, complex 3 lacking an imidazole ring and complex 4 bearing a thiazole ring in place of imidazole both showed minimal response to F− (Figures 1b and S5). These results suggest that quenching is associated with interactions at the imidazole sites. Considering that complex 1 gave the maximum response (15-fold reduction), we selected 1 as the lead sensor for F− detection. 2.2. Luminesce Emission Response of 1 toward F−. We initially examined the luminescence response of 1 to F−. Without F−, 1 displayed strong luminescence intensity in solvent system DMSO/H2O (9:1, v/v). However, when F− was added, the luminescence intensity of 1 was quenched significantly (Figure 2). We next examined the use of other organic solvents (in combination with 10% H2O), including N,N-dimethylformamide (DMF), acetonitrile (ACN), acetone, and ethanol (EtOH). The results showed that DMSO provided the best probe performance to F− (Figure S6). Moreover, the optimal ratio of DMSO and H2O was determined to be 9:1 (v/ v), with higher amounts of H2O leading to a lower quenching response (Figure S7). In emission titration experiments, complex 1 (10 μM) showed gradually reduced luminescence intensity with increasing concentrations of F−. The luminescence intensity reached its minimum at 40 molar equiv of F−, with a 15-fold reduction (Figure 2a). A linear relationship (R2 = 0.991) was established from 2 to 10 μM F−, and a detection limit (S/N = 3) of 0.75 μM was recorded (Figure 2b).

Figure 1. (a) Structures of complexes 1−4. (b) Fold change of complexes 1−4 (10 μM) in the presence of F− (0.5 mM) in dimethyl sulfoxide (DMSO)/H2O (9:1, v/v).

2.3. Selectivity Studies of Anions to 1. The selectivity of sensor 1 for F− over other potential interfering anions was examined. The luminescence response of 1 (10 μM) in the presence of 0.4 mM anions, such as I−, Br−, Cl−, SO42−, S2O32−, NO2−, NO3−, N3−, and SCN−, was recorded (Figure 3). The results showed that only F− led to obvious changes in luminescence response, whereas the rest of the anions caused no significant response under the same conditions. To further demonstrate the specificity of the sensor to F−, we performed competition studies by adding F− (0.4 mM) to complex 1 (10 μM) in the presence of other anions (0.4 mM). The result 9151

DOI: 10.1021/acsomega.7b01646 ACS Omega 2017, 2, 9150−9155

Article

ACS Omega

Figure 2. (a) Luminescence spectra of 1 (10 μM) with increasing concentration of F− (0−50 molar equiv, sodium fluoride aqueous solution) in DMSO/H2O (9:1, v/v), λex = 300 nm. (b) Relationship between luminescence intensity and F− concentration.

Figure 3. Luminescence response of 1 (10 μM) to different anions. The black bars represent the addition of 0.4 mM different anions to the solution of 1. The red bars represent the subsequent addition of 0.4 mM F− to the solution, λex = 300 nm.

showed no significant change in luminescence emission, indicating that 1 has the ability to selectively detect F− even when these other common interfering anions were present. 2.4. Detection of Al3+ by 1-F. As a tandem detection strategy for both fluoride and aluminum ions, we then examined the luminescence signal of complex 1-F to Al3+. To achieve this, complex 1-F was prepared from 10 μM 1 with a 1:40 molar equiv ratio of 1:F− in solvent system DMSO/H2O (9:1, v/v) and the resulting solution was treated with increasing concentrations of aluminum ions (0.2−5 μM). The luminescence intensity of 1 went up linearly with the increasing concentrations of Al3+, with a maximal ca. 15-fold luminescence enhancement at [Al3+] = 5 μM (Figure 4a). A linear relationship (R2 = 0.999) was established from 0 to 1.4 μM Al3+, and a detection limit of 0.2 μM was recorded (Figure 4b). Interestingly, 0.5 molar equiv of Al3+ was sufficient for full luminescence recovery, which could be ascribed to Al3+ multicoordination with 1-F. To verify the tandem interaction among 1, F−, and Al3+, the reactions were monitored by 1H NMR spectroscopy (Figure S8). The pbim (H at 8.01 ppm) proton signal of 1 was downfield-shifted, suggesting the presence of hydrogen bond interactions. Moreover, the luminescence on−off−on of sensor 1 in tandem response to F− and Al3+ could be easily visualized by eye under UV illumination (Figure 5). 2.5. Selectivity Studies of Metal Ions to 1-F. To investigate the selectivity of this Al3+ detection method, common metal ions were added into the 1-F mixture in DMSO/H2O (9:1, v/v). Upon addition of 1 equiv of various

Figure 4. (a) Luminescence spectra of 1-F (10 μM, 1:40 molar equiv ratio) with increasing concentration of Al3+ (0−5.5 μM) in DMSO/ H2O (9:1, v/v). (b) Relationship between luminescence intensity and Al3+ concentration, λex = 300 nm.

metal ions to 1 (10 μM), including Zn2+, Ni2+, Cd2+, Ba2+, Fe3+, Cu2+, Mg2+, Cr3+, Ca2+, Pb2+, K+, Ag+, Mn2+, and Ce3+, the enhancement of luminescent response of 1-F was negligible in comparison to the response for 0.4 equiv of Al3+ (Figure 6). This shows that the probe has excellent selectivity toward Al3+ (Figure 6). We believe that this is because Al3+ binds fluoride with great affinity than other metal cations.34 2.6. Reversibility of Sensor 1. Finally, we explored the reversibility of the tandem detection method for F− and Al3+. Complex 1 (10 μM) was treated with 40 equiv of F−, which induced luminescence quenching. Five minutes later, the solution was treated with 0.4 equiv of Al3+, leading to 9152

DOI: 10.1021/acsomega.7b01646 ACS Omega 2017, 2, 9150−9155

Article

ACS Omega

result suggests that probe 1 can be used for the reversible tandem measurement of F− and Al3+ in solution.

3. CONCLUSIONS We have reported a new luminescent chemosensor, 1, for tandem F− and Al3+ detection via hydrogen bond interactions. The results show that the luminescence of complex 1 can be readily quenched by F−, forming complex 1-F, and upon addition of Al3+, its luminescence can be restored. On the basis of the above results, a luminescent switch on−off−on tandem sensor for F− and Al3+ was developed. Moreover, 1-F showed a linear response to Al3+ from 0.2 to 1.4 μM and showed an excellent selectivity to Al3+. Moreover, the reversibility of the on−off−on sensor to tandemly monitor F− and Al3+ was demonstrated. We anticipate that this probe could be further optimized to generate an on−off−on sensor that could be used in biological systems.

Figure 5. Photographs of 10 μM 1 (left), with 40 equiv of F− (center), and then 0.4 equiv of Al3+ (right) in DMSO/H2O (9:1, v/v) under UV illumination.

4. MATERIALS AND METHODS 4.1. F− and Al3+ Detection. The stock solution of 2.5 mM complex 1 was prepared in acetonitrile (ACN). The complex was then added into dimethyl sulfoxide (DMSO)/water (H2O) (9:1, v/v) to a final concentration of 10 μM. Different concentrations of F− were then added to the DMSO/H2O mixture with complex 1 (10 μM) in a cuvette. As for the tandem detection of Al3+, 0.4 mM F− and 10 μM 1 were mixed in DMSO/H2O in a cuvette and then different concentrations of Al3+ were then added to the solution. Luminescence emission spectra were recorded on a PTI QM-1 spectrofluorometer (Photo Technology International, Birmingham, NJ) under ambient temperature, with the slits for both excitation and emission set at 2.5 nm. UV−vis absorption spectra were recorded on a Cary UV-300 spectrophotometer (double beam). 4.2. Synthesis of Complexes 1−4. A solution of the N∧N ligand (0.12 mmol) and dichloro-bridged [Ir(C∧N)2Cl]2 (0.056 mmol) in dichloromethane (3 mL) and methanol (3 mL) was stirred at 60 °C overnight. After the reaction completed, an excess of ammonium hexafluorophosphate (NH4PF6) solid was added and the reaction mixture was stirred for another 0.5 h at room temperature. The solvent was removed under reduced pressure, and the residue was purified by silica gel column chromatography (eluent, methanol/dichloromethane, 1/20, v/ v) to yield complexes 1−4.

Figure 6. Luminescence response of 1-F (10 μM) with 0.4 molar equiv of Al3+ or 1.0 molar equiv of other metal ions in DMSO/H2O (9:1, v/v), λex = 300 nm.

restoration of luminescence. After luminescence returned to the initial levels, another 80 equiv of F− was introduced into the mixture and luminescence of the solution was quenched again. Five minutes later, the solution was treated with a further 0.8 equiv of Al3+, restoring the luminescence a second time. Continuing in similar fashion, the on−off cycle could be repeated at least three times (Figure 7). Furthermore, this hydrogen bond interaction cycle could be reversed several times without a decrease in the maximum luminescence. This



ASSOCIATED CONTENT

S Supporting Information *

The Supporting Information is available free of charge on the ACS Publications website at DOI: 10.1021/acsomega.7b01646. General experimental procedures, materials, photophysical measurement, synthesis of 1, photophysical properties, UV−vis absorption spectra, solvent screening experiments, and partial 1H NMR spectra details (PDF)



AUTHOR INFORMATION

Corresponding Authors

*E-mail: [email protected]. Phone: (+86) 0797-8312204 (R.X.W.). *E-mail: [email protected]. Phone: (+853) 8822-4688 (C.-H.L.). *E-mail: [email protected]. Phone: (+852) 3411-7075 (D.-L.M.).

Figure 7. Luminescence response of 1 (10 μM) to the sequential addition of F− (40 equiv for the first time, 80 equiv for others) and Al3+ (0.4 equiv for the first time, 0.4 equiv for others), λex = 300 nm. 9153

DOI: 10.1021/acsomega.7b01646 ACS Omega 2017, 2, 9150−9155

Article

ACS Omega ORCID

(11) Gupta, A.; Kumar, N. A review of mechanisms for fluorescent “turn-on”probes to detect Al3+ ions. RSC Adv. 2016, 6, 106413− 106434. (12) Lu, Y.; Huang, S.; Liu, Y.; He, S.; Zhao, L.; Zeng, X. Highly selective and sensitive fluorescent turn-on chemosensor for Al3+ based on a novel photoinduced electron transfer approach. Org. Lett. 2011, 13, 5274−5277. (13) Ghosh, K.; Majumdar, A.; Sarkar, T. Selective sensing of Al3+ by naphthyridine coupled rhodamine chemosensors. RSC Adv. 2014, 4, 23428−23432. (14) Hossain, S. M.; Lakma, A.; Pradhan, R. N.; Chakraborty, A.; Biswas, A.; Singh, A. K. Synthesis and characterization of a novel, ditopic, reversible and highly selective,“Turn-On” fluorescent chemosensor for Al3+ ion. RSC Adv. 2015, 5, 63338−63344. (15) Kang, R.; Shao, X.; Peng, F.; Zhang, Y.; Sun, G.-T.; Zhao, W.; Jiang, X.-D. A highly selective turn-on fluorescent chemosensor for Al3+ imaging in living cells via through-bond energy transfer. RSC Adv. 2013, 3, 21033−21038. (16) Wang, Y.; Xiong, L.; Geng, F.; Zhang, F.; Xu, M. Design of a dual-signaling sensing system for fluorescent ratiometric detection of Al3+ ion based on the inner-filter effect. Analyst 2011, 136, 4809− 4814. (17) Maity, D.; Govindaraju, T. Pyrrolidine constrained bipyridyldansyl click fluoroionophore as selective Al3+ sensor. Chem. Commun. 2010, 46, 4499−4501. (18) Gui, S.; Huang, Y.; Hu, F.; Jin, Y.; Zhang, G.; Yan, L.; Zhang, D.; Zhao, R. Fluorescence turn-on chemosensor for highly selective and sensitive detection and bioimaging of Al3+ in living cells based on ioninduced aggregation. Anal. Chem. 2015, 87, 1470−1474. (19) Hau, F. K.-W.; He, X.; Lam, W. H.; Yam, V. W.-W. Highly selective ion probe for Al3+ based on Au (i)−Au (i) interactions in a bis-alkynyl calix [4] arene Au (i) isocyanide scaffold. Chem. Commun. 2011, 47, 8778−8780. (20) Chen, C.-H.; Liao, D.-J.; Wan, C.-F.; Wu, A.-T. A turn-on and reversible Schiff base fluorescence sensor for Al3+ ion. Analyst 2013, 138, 2527−2530. (21) Liu, Q.; Yin, B.; Yang, T.; Yang, Y.; Shen, Z.; Yao, P.; Li, F. A general strategy for biocompatible, high-effective upconversion nanocapsules based on triplet−triplet annihilation. J. Am. Chem. Soc. 2013, 135, 5029−5037. (22) Tao, Y.; Li, M.; Ren, J.; Qu, X. Metal nanoclusters: novel probes for diagnostic and therapeutic applications. Chem. Soc. Rev. 2015, 44, 8636−8663. (23) Kirsch, J.; Siltanen, C.; Zhou, Q.; Revzin, A.; Simonian, A. Biosensor technology: recent advances in threat agent detection and medicine. Chem. Soc. Rev. 2013, 42, 8733−8768. (24) Wang, W.; Mao, Z.; Wang, M.; Liu, L.-J.; Kwong, D. W.; Leung, C.-H.; Ma, D.-L. A long lifetime luminescent iridium (iii) complex chemosensor for the selective switch-on detection of Al3+ ions. Chem. Commun. 2016, 52, 3611−3614. (25) Thiampanya, P.; Muangsin, N.; Pulpoka, B. Azocalix[4]arene strapped calix[4]pyrrole: a confirmable fluoride sensor. Org. Lett. 2012, 14, 4050−4053. (26) Tang, L.; Cai, M.; Huang, Z.; Zhong, K.; Hou, S.; Bian, Y.; Nandhakumar, R. Rapid and highly selective relay recognition of Cu(II) and sulfide ions by a simple benzimidazole-based fluorescent sensor in water. Sens. Actuators, B 2013, 185, 188−194. (27) Rochat, S.; Severin, K. A simple fluorescence assay for the detection of fluoride in water at neutral pH. Chem. Commun. 2011, 47, 4391−4393. (28) Qu, W.-J.; Guan, J.; Wei, T.-B.; Yan, G.-T.; Lin, Q.; Zhan, Y.-M. A turn-on fluorescent sensor for relay recognition of two ions: from a F−-selective sensor to highly Zn2+-selective sensor by tuning electronic effects. RSC Adv. 2016, 6, 35804−35808. (29) Gao, G.-Y.; Qu, W-J.; Shi, B.-B.; Lin, Q.; Yao, H.; Chang, J.; Cai, Y. A reversible fluorescent chemosensor for iron ions based on 1Himidazo [4, 5-b] phenazine derivative. Sensor. Actuat. B-Chem. 2015, 213, 501−507.

Chung-Hang Leung: 0000-0003-2988-3786 Dik-Lung Ma: 0000-0002-9515-340X Author Contributions

The manuscript was written through contributions of all authors. Notes

The authors declare no competing financial interest.



ACKNOWLEDGMENTS We acknowledge the support by Hong Kong Baptist University (FRG2/16-17/007), the Health and Medical Research Fund (HMRF/14130522 and 14150561), the Research Grants Council (HKBU/12301115), the National Natural Science Foundation of China (21575121, 21628502, 21762018, and 51564021), the Guangdong Province Natural Science Foundation (2015A030313816), the Hong Kong Baptist University Century Club Sponsorship Scheme 2017, the Interdisciplinary Research Matching Scheme (RC-IRMS/15-16/03), the Innovation and Technology Fund (ITS/260/16FX), the Matching Proof of Concept Fund (MPCF-001-2017/18), the Science and Technology Development Fund, Macao SAR (077/2016/A2), the University of Macau (MYRG2015-00137ICMS-QRCM, MYRG2016-00151-ICMS-QRCM, and MRG044/LCH/2015/ICMS), and the Natural Science Foundation of Jiangxi Province (20171BAB213008 and 20151BAB206028), Program of Qingjiang Excellent Young Talents, Jiangxi University of Science and Technology.



REFERENCES

(1) Kirk, K. L. Biochemistry of Inorganic Fluoride. Biochemistry of the Elemental Halogens and Inorganic Halides; Springer, 1991; pp 19−68. (2) Briançon, D. Fluoride and osteoporosis: an overview. Rev. Rhum. Engl. Ed. 1997, 64, 78−81. (3) Jha, S. K.; Mishra, V. K.; Sharma, D. K.; Damodaran, T. Fluoride in the Environment and Its Metabolism in Humans. Reviews of Environmental Contamination and Toxicology; Springer, 2011; Vol. 211, pp 121−142. (4) Zhou, Y.; Zhang, J. F.; Yoon, J. Fluorescence and colorimetric chemosensors for fluoride-ion detection. Chem. Rev. 2014, 114, 5511− 5571. (5) Verstraeten, S. V.; Aimo, L.; Oteiza, P. I. Aluminium and lead: molecular mechanisms of brain toxicity. Arch. Toxicol. 2008, 82, 789− 802. (6) Hornung, V.; Bauernfeind, F.; Halle, A.; Samstad, E. O.; Kono, H.; Rock, K. L.; Fitzgerald, K. A.; Latz, E. Silica crystals and aluminum salts activate the NALP3 inflammasome through phagosomal destabilization. Nat. Immunol. 2008, 9, 847−856. (7) Konieczka, P.; Zygmunt, B.; Namiesnik, J. Comparison of fluoride ion-selective electrode based potentiometric methods of fluoride determination in human urine. Bull. Environ. Contam. Toxicol. 2000, 64, 794−803. (8) Tong, A.; Akama, Y.; Tanaka, S. Pre-concentration of copper, cobalt and nickel with 3-methyl-1-phenyl-4-stearoyl-5-pyrazolone loaded on silica gel. Analyst 1990, 115, 947−949. (9) Rao, G. P. C.; Seshaiah, K.; Rao, Y. K.; Wang, M. Solid phase extraction of Cd, Cu, and Ni from leafy vegetables and plant leaves using amberlite XAD-2 functionalized with 2-hydroxy-acetophenonethiosemicarbazone (HAPTSC) and determination by inductively coupled plasma atomic emission spectroscopy. J. Agric. Food Chem. 2006, 54, 2868−2872. (10) Itai, K.; Tsunoda, H. Highly sensitive and rapid method for determination of fluoride ion concentrations in serum and urine using flow injection analysis with a fluoride ion-selective electrode. Clin. Chim. Acta 2001, 308, 163−171. 9154

DOI: 10.1021/acsomega.7b01646 ACS Omega 2017, 2, 9150−9155

Article

ACS Omega (30) Ko, C. N.; Yang, C.; Lin, S.; Li, S.; Dong, Z.; Liu, J.-B.; Ma, D.L.; et al. A long-lived phosphorescence iridium(III) complex as a switch on-off-on probe for live zebrafish monitoring of endogenous sulfide generation. Biosens. Bioelectron. 2017, 94, 575−583. (31) Li, S.; Zhang, C.; Huang, S.; Hu, F.; Yin, J.; Liu, S. H. Highly selective colorimetric and fluorescent sensors for the fluoride anion based on imidazo [4, 5-f ]-1, 10-phenanthroline metal-complexes. RSC Adv. 2012, 2, 4215−4219. (32) Sai Sathish, R.; Kumar, M. R.; Rao, G. N.; Kumar, K. A.; Janardhana, C. A water-soluble fluorescent fluoride ion probe based on Alizarin Red S−Al (III) complex. Spectrochim. Acta, Part A 2007, 66, 457−461. (33) Ghorai, A.; Mondal, J.; Chandra, R.; Patra, G. K. A reversible fluorescent-colorimetric imino-pyridyl bis-Schiff base sensor for expeditious detection of Al3+ and HSO3− in aqueous media. Dalton Trans. 2015, 44, 13261−13271. (34) Martin, R. B. Ternary complexes of Al3+ and F− with a third ligand. Coord. Chem. Rev. 1996, 149, 23−32.

9155

DOI: 10.1021/acsomega.7b01646 ACS Omega 2017, 2, 9150−9155