Nanomechanical Properties of Phospholipid Microbubbles - Langmuir

Department of Materials Science and Engineering, University of Michigan, ... for Cardiovascular Sciences, Chancellor's Building, The University of Edi...
0 downloads 0 Views 774KB Size
Article pubs.acs.org/Langmuir

Nanomechanical Properties of Phospholipid Microbubbles Evelyn Buchner Santos,† Julia K. Morris,† Emmanouil Glynos,‡ Vassilis Sboros,§ and Vasileios Koutsos*,† †

Institute for Materials and Processes, School of Engineering, The University of Edinburgh, The King’s Buildings, Edinburgh EH9 3JL, United Kingdom ‡ Department of Materials Science and Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States § Medical Physics and Centre for Cardiovascular Sciences, Chancellor’s Building, The University of Edinburgh, Edinburgh EH16 4SB, United Kingdom ABSTRACT: This study uses atomic force microscopy (AFM) force− deformation (F−Δ) curves to investigate for the first time the Young’s modulus of a phospholipid microbubble (MB) ultrasound contrast agent. The stiffness of the MBs was calculated from the gradient of the F−Δ curves, and the Young’s modulus of the MB shell was calculated by employing two different mechanical models based on the Reissner and elastic membrane theories. We found that the relatively soft phospholipid-based MBs behave inherently differently to stiffer, polymer-based MBs [Glynos, E.; Koutsos, V.; McDicken, W. N.; Moran, C. M.; Pye, S. D.; Ross, J. A.; Sboros, V. Langmuir 2009, 25 (13), 7514−7522] and that elastic membrane theory is the most appropriate of the models tested for evaluating the Young’s modulus of the phospholipid shell, agreeing with values available for living cell membranes, supported lipid bilayers, and synthetic phospholipid vesicles. Furthermore, we show that AFM F−Δ curves in combination with a suitable mechanical model can assess the shell properties of phospholipid MBs. The “effective” Young’s modulus of the whole bubble was also calculated by analysis using Hertz theory. This analysis yielded values which are in agreement with results from studies which used Hertz theory to analyze similar systems such as cells.



bonded noncovalently with the outer surface11 by methods such as layer-by-layer assembly.12,13 Diffusion or degradation methods may be used to release the cargo;12 for instance, once the preloaded MBs have reached the desired location in the body, the applied ultrasound frequency and/or acoustic power can be adjusted to induce MB collapse and, where appropriate, assist drug uptake through membrane sonoporation.14 This efficient, noninvasive method of drug (and gene) delivery has been proven to reduce the required drug dosage, as it is only being administered to the target location, rather than affecting the entire body.15 Furthermore, if this procedure is used to deliver cytotoxic drugs, the potential hazard to the patient may be significantly reduced.16 Such a localization technique has the potential to replace systemic medical treatments, such as wholebody chemotherapy. Recent studies are investigating the possibility of dual modality and multifunctional MBs, where imaging, targeting, and therapeutic agents would be combined in a single bubble.17 To this end, a full understanding and characterization of the MBs is necessary in order to ensure benign practices.18 The development of this technology is dependent on building an understanding of the mechanical properties of the MBs in addition to their acoustic behavior. Various techniques to elicit a deformation of MBs are available such as micropipet aspiration19,20 or osmotic swelling,21 but it is the development of atomic force microscopy (AFM) which has provided us with

INTRODUCTION Microbubbles (MBs) are widely used in the medical field in activities ranging from therapeutic imaging to drug delivery. In the early 1970s, biocompatible contrast agents began to be investigated as a tool for enhancing ultrasound imaging,1,2 which is now a standard procedure used to visualize real time blood flow. Currently, MBs are being used for tumor visualization, providing excellent ultrasound imagery of damaged areas that contain high blood concentration.3,4 Promising results from this imaging mode that show accurate monitoring of the angiogenic process of cancer and the corresponding therapeutic interventions may have significant implications in patient management, suggesting a reduction in the time scale for treatment decisions from months to days, thus potentially reducing mortality rates.5 As MBs were designed for use as contrast agents, a great deal of research has been conducted into their behavior under diagnostic ultrasound.6 In order to work efficiently as contrast agents for ultrasound imaging, inert MBs contain gases that create low-density regions in the bloodstream. The pressure difference causes an increase in radial oscillation when diagnostic ultrasound waves are applied.7,8 MBs have been proven to be suitable for the visualization of the vascular bed of various tissues, such as the heart,9 the liver,10 the kidney,5 and others, with several diagnostic applications increasingly used routinely in the clinic. Using this high-precision imaging technology, methods of drug delivery can be envisaged based on the concept of “magic bullets”.8 MBs can act as a scaffold to which drugs or genes can be constrained in a number of ways: in the inner area, within or attached to the membrane, or © 2012 American Chemical Society

Received: December 5, 2011 Revised: February 3, 2012 Published: February 7, 2012 5753

dx.doi.org/10.1021/la204801u | Langmuir 2012, 28, 5753−5760

Langmuir

Article

suitability of each of the three mechanical models is then discussed within the context of existing literature describing similar and comparable systems such as vesicles, cells, and lipid bilayers.

the ability to measure the mechanical response of MBs with nanoscale force resolution. AFM has already provided insights into the mechanical behavior of polyelectrolyte microcapsules22 and other soft particles23 in the size range of ultrasound contrast agent (UCA) MBs. We have previously introduced AFM as a powerful tool for the investigation of polymer-based MBs, conducting a detailed investigation into the nanomechanical properties and behavior of MBs with a view to evaluating their Young’s moduli.24,25 These studies revealed important information about the nanomechanical properties of MBs; in ref 24, in particular, we showed results which explain a possible cause of a failure of UCA technology. Using AFM, we found a variation of the Young’s modulus of the shell with thickness at the nano scale, which contradicts the presumption that the Young’s modulus is a constant material property, independent of size or shape. However, this finding is specific for polymeric MBs; it does not imply that other thin shell structures based on different materials will behave in the same way, and other types of MB must be investigated for possible nanoscale size-dependent effects. Phospholipid-coated MBs are a promising alternative material to meet the difficult environmental conditions required for the MB to remain in liquid solution (the blood) without failing for a designated time period (blood half-life).8 Lipids form very flexible membranes, which can be stabilized against factors such as temperature, pressure, concentration, and composition of gas.8 Our own initial work on phospholipid MBs focused on MB imaging26 and force measurements exploring stiffness and adhesive properties, as well as exploring the possibility of phospholipid MB targeting via avidin−biotin surface chemistry.27,28 Recently, AFM has been used by others to measure the stiffness of in-house fabricated lipid coated MBs29 and also to investigate the effect of temperature on their viscoelastic behavior.30 The (intrinsic) mechanical properties of the phospholipid shell of MBs have yet to be accurately specified; however, studies exist measuring the properties of similar phospholipid membrane systems, such as vesicles, cells, and supported lipid bilayers. Many previous studies have investigated the mechanical properties of phospholipid vesicles,19,21,31−33 which can be found in more than one size scale, with diameters from