Nitrogen Compounds (NO, NO2, N2O, and NH3) in NOx Emissions

Engineering, Hanyang University, Seoul 04763, Republic of Korea. Energy Fuels , 2016, 30 (8), pp 6828–6834. DOI: 10.1021/acs.energyfuels.6b01331...
5 downloads 13 Views 1MB Size
Subscriber access provided by Northern Illinois University

Article

Nitrogen compounds (NO, NO2, N2O and NH3) in NOx emissions from commercial EURO VI type heavy-duty diesel engines with a urea-selective catalytic reduction system Joonho Jeon, Jong Tae Lee, and Sungwook Park Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/acs.energyfuels.6b01331 • Publication Date (Web): 29 Jul 2016 Downloaded from http://pubs.acs.org on August 5, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 1

1

Nitrogen compounds (NO, NO2, N2O and NH3) in NOx emissions

2

from commercial EURO VI type heavy-duty diesel engines with a

3

urea-selective catalytic reduction system

4

Joonho Jeon†, Jong Tae Lee‡, Sungwook Park§,*

5



6

University, Seoul 04763, Republic of Korea

7



National Institute of Environmental Research, Incheon 22689, Republic of Korea

8

§

School of Mechanical Engineering, Hanyang University, Seoul 04763, Republic of Korea

9

Submitted to “Energy & Fuels”

10

Submission date: July 22, 2016

11

* Corresponding author

12

Sungwook Park

13

Associate Professor

14

School of Mechanical Engineering,

15

Hanyang University,

16

222 Wangsimni-ro, Seongdong-gu, Seoul 04763, Republic of Korea

17

Tel. : +82-2-2220-0430

18

Fax : +82-2-2280-4588

19

E-mail : [email protected]

Department of Mechanical Convergence Engineering, Graduate School of Hanyang

20

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 34 2

21

Abstract

22

Selective catalytic reduction (SCR) systems have been widely used in heavy-duty (HD) diesel

23

engines to meet the stringent emission standards for nitrogen oxides. Mobile SCR system has

24

improved the considerable reduction of NOx emission from HD diesel engines. Many

25

investigations have performed to enhance the catalytic performance and optimize the SCR

26

system within the diesel engines. The purpose of the present study was to investigate the

27

types of nitrogen components (NO, NO2, N2O, and NH3) in the NOx exhaust emissions prior

28

to and after passing through an SCR device. A EURO VI type commercial heavy-duty diesel

29

engine was equipped to an AC dynamometer. World harmonized stationary cycle and

30

transient cycle were introduced to operate the test engine under road conditions. A new

31

quantum–cascade laser analyzer was employed to measure the nitrogen emission species in

32

real time. The engine-out NOx emissions were strongly affected by the load conditions of the

33

engine, which also determined the efficiency of SCR conversion. Total conversion rates of up

34

to 96% were achieved for both test modes. Various concentration of urea were used as a

35

reducing agent in the SCR system. Based on the urea concentration, the conversion efficiency

36

and composition of nitrogen oxides varied under the same engine conditions. The fraction of

37

nitrogen compounds in NOx emissions changed during the catalytic processes within the SCR

38

system. The results yielded accurate concentration values for nitrogen compounds in the

39

commercial heavy-duty engine, warning of the possibility of a new greenhouse gas due to

40

converted NOx emissions.

41

Keywords

42

EURO VI, Heavy–duty, Nitrogen oxide, Selective catalytic reduction, Nitric oxide, Nitric

43

dioxide, Nitrous oxide, Ammonia, WHSC, WHTC

ACS Paragon Plus Environment

Page 3 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 3

44

Nomenclature

45

Carbon monoxide

CO

46

Coefficient of variation

CoV

47

Constant volume sampler

CVS

48

Diesel oxidation catalyst

DOC

49

Engine control unit

ECU

50

Greenhouse gas

GHG

51

Heavy–duty

HD

52

Nitrogen oxides

NOx

53

Nitrogen dioxide

NO2

54

Nitric oxide

NO

55

Nitrous oxide

N2 O

56

Particulate matter

PM

57

Portable emissions measurement system PEMS

58

Quantum–cascade laser

QCL

59

Selective catalytic reduction

SCR

60

Total hydrocarbon

THC

61

World harmonized stationary cycle

WHSC

62

World harmonized transient cycle

WHTC

63

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 34 4

64

1. Introduction

65

Selective catalytic reduction (SCR) systems have been applied to heavy–duty (HD)

66

diesel engines as an after-treatment system to reduce nitrogen oxides emissions, which are

67

considered to be noxious gases within the air. To meet strict emissions regulations, EURO VI,

68

an SCR technology that has been used in industrial stationary applications, was introduced to

69

treat the nitrogen oxide (NOx) emissions of mobile diesel engines

70

SCR technology developments, urea-SCR devices were selected by a number of

71

manufacturers for the light– and heavy–duty diesel engines 4. Urea, NH2–CO–NH2, is an

72

SCR reductant substitute for ammonia, which is toxic and difficult to handle. An aqueous

73

urea solution was injected into the exhaust gas stream at the entrance of the SCR system.

74

Under high temperature conditions, the urea solutions decomposed via the following

75

hydrolysis reaction.

1,-3

. As a result of many

76

(1)

77

Equation (1) reveals the global urea decomposition process. Among the various urea

78

decomposition products, ammonia is used as a reducing agent in the SCR system to reduce

79

NOx emissions. The main SCR reactions are suggested as follows:

80

(2)

81

(3)

82

(4)

83

With regard to the NOx emissions produced by a diesel engine, nitric oxide (NO)

84

comprises over 90% of the emissions. Equation (2) is thus considered to be the primary

85

reaction for the reduction of NOx in the urea-SCR system. Equation (3) does not consume

ACS Paragon Plus Environment

Page 5 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 5

86

oxygen, which is a much slower reaction 5. The presence of nitrogen dioxide (NO2)

87

accelerated the NOx conversion reactions seen in Eq. (4). When the quantities of NO and NO2

88

were equimolar, the reaction rate was much faster than that of the main reaction (2)

89

Related to the NO2 concentration in emissions, DeNOx reaction rates have been investigated

90

by various research groups. Since the mobile SCR system should be concerned with costs,

91

catalyst materials have been developed as the primary subject of SCR research in the last

92

decade. State-of-the-art commercial SCR system have been developed with Vanadium-base 9-

93

11

94

systems in industry are operated under steady-state conditions, mobile SCR devices are

95

driven under transient temperature conditions. DeNOx performance is also strongly

96

influenced by temperature. Commercial SCR after-treatment systems are optimized to operate

97

under a wide range of temperature conditions with a large number of investigations.

, Cu-zeolite

12, 13

, and Fe-zeolite

14-17

6-8

.

based SCR catalysts. Additionally, although the SCR

98

However, most of the performed research was conducted with chemical aspects under

99

laboratories’ conditions. There were few results to concern the SCR device coupled to the 18

100

actual engine system. Misra et al.

101

2010 and 2011 HD diesel engines and evaluated the emitted NOx levels during road driving

102

with a portable emissions measurement system (PEMS). Four different trucks were used to

103

compare the reduction in NOx and the effects of various vehicle conditions. Misra et al.

104

reported their experimental results, revealing the effects of temperature and load conditions

105

on the potential to control NOx emissions. Myung et al.

106

HD engine performance and emission characteristics under various driving cycle modes,

107

referencing the European cycle (ESC/ETC) and worldwide harmonized driving cycles

108

(WHSC/ WHTC). They compared the regulated emissions (THC, CO, NOx, and PM)

109

concentrations under four driving cycles. The test results reported that the newly introduced

110

cycles (WHSC/WHTC) featured lower exhaust temperatures and a better reflection of

investigated the in-use NOx emissions for model year

19

conducted a study with regard to

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 34 6

111

practical HD diesel engines than the European modes. SCR system research coupled with

112

hybrid– and conventional diesel–buses was reported by Guo’s groups

113

types of bus engines on the road conditions with PEMS to measure the NOx emissions. Two

114

hybrid buses and two conventional diesel buses were compared in terms of their fuel

115

economy and converted NOx emissions after passing through the post-treatment system. The

116

results revealed that the hybrid system exhibited slightly higher NOx concentrations due to

117

lower exhaust temperatures, which deteriorated SCR performance. When the hybrid buses

118

were driving on city routes, NOx emissions exceeded the EURO IV standards.

20

. They tested two

119

Among the previous research results, many studies have been focused on SCR catalysts

120

during the early 2000’s. Recently, studies have not dealt with SCR systems related to the

121

latest emissions standards. This study aims to perform a profound investigation with regard to

122

nitrogen oxides in a EURO VI type HD diesel engine. The present research would be a

123

milestone to DeNOx processing at EURO VI levels. The engine experiments were processed

124

using the world harmonized stationary cycle (WHSC) and transient cycle (WHTC). In

125

addition, a new analyzer using a quantum–cascade laser method enabled the accurate

126

measurement of nitrogen emission components in exhausted nitrogen oxides.

127

ACS Paragon Plus Environment

Page 7 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 7

128

2. Experimental methodology

129

2.1 Engine system

130

The measurement of nitrogen species (NO, NO2, N2O, and NH3) was performed on a

131

commercial heavy-duty diesel engine, meeting the EURO VI regulations. The heavy–duty

132

engine possessed a displacement of 12.7 liters over 6 cylinders, which can generate 323.6 kW

133

maximum power at the 1800 rpm. Due to stringent emission standards, additional after-

134

treatment devices were required to conform to regulations. In the present system, state-of-the-

135

art technologies were employed to reduce exhaust emissions to within standard levels. First,

136

diesel oxidation catalysts (DOC) were connected to the exhaust pipe to promote the oxidation

137

of carbon monoxide (CO), total hydrocarbons (THC), and the organic fraction of diesel

138

particulates. After the DOC device, a selective catalytic reduction (SCR) composed of a

139

Cu/Zeolite catalyst was linked to convert nitrogen oxides to non-noxious species such as

140

nitrogen gas and water. Harmful emitted particulate matters were burned through the diesel

141

particulate filter system. Finally, ammonia oxidation catalysts removed ammonia after the

142

SCR system. The test engine also employed an exhaust gas recirculation system to minimize

143

NOx production during the combustion process. Detailed engine specifications are tabulated

144

in Table 1. The heavy-duty engine was linked to an AC dynamometer (HD 460 LC,

145

HORIBA), which is an AC induction motor that can control the engine speed and torque.

146

Rated power and torque of the dynamometer were up to 462 kW and 2680 Nm, respectively.

147

A commercial engine control unit (ECU) commanded entire engine electrical system based

148

on the designated engine conditions set by the manufacturer. The software (STARS,

149

HORIBA) simultaneously communicated cycle information to the dynamometer and ECU.

150

With regard to emissions measurements, a constant volume sampler (CVS) system was

151

employed after the post-treatment devices, which is an official method to measure engine

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 34 8

152

exhaust emissions. The CVS system detected regulated emissions (CO, THC, and NOx)

153

during the test cycle operation. The emissions analyzer (MEXA–7200D, HORIBA) measured

154

diluted emissions using a bag sampling system, which can evaluate and compare emissions

155

levels to the EURO VI limits. In this study, a quantum–cascade laser (QCL) analyzer was

156

introduced to measure emissions related to nitrogen components such as nitric oxide, nitrogen

157

dioxide, nitrous oxide, and ammonia gases. The QCL analyzer uses an infrared absorption

158

method, which improved the precision of the emissions measurement compared to the

159

Fourier Transform Infrared method. The device could measure and record four gases in real

160

time over 1 second intervals. There were two measuring points for the QCL detectors; one

161

location was before the after-treatment device inlet and the other was at the rear of the SCR

162

system. Figure 1 illustrates a schematic of the test engine and emissions system. Analyzing

163

and comparing the values measured between the two points showed the emission conversion

164

efficiency of the post–system along with other relevant information.

165 166

2.2 Experimental procedures

167

The official engine dynamometer schedules of the EURO VI emissions regulations were

168

used for the heavy–duty engine. The schedules are composed of transient and steady modes.

169

The United Nations Economic Commission for Europe defined two representative test cycles,

170

the world harmonized transient cycle (WTHC) and world harmonized stationary cycle

171

(WHSC), serving to cover the typical driving conditions in various countries. Normalized

172

engine speeds and torques for each cycle can be seen in Fig 2. The WHTC mode has the wide

173

range of engine speeds and loads for the entire duration of 1800 seconds. The WHSC mode

174

consisted of a ramped steady-state cycle composed of 13 modes, including an idling mode.

175

Although WHTC officially separated cold and hot conditions, a new warm-up condition was

ACS Paragon Plus Environment

Page 9 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 9

176

introduced in the present study due to test time limitations. The pre-operation conditions for

177

the WHSC were performed following formal test procedures using the 9 mode for 10 minutes.

178

All tests were repeated 3 times and their results were averaged to reduce variations between

179

tests. The coefficient of variation (CoV) was used to evaluate errors of the averaged NOx

180

emissions values. The CoVs of averaged NO, N2O, and NO2 emissions were under 10%

181

except for the near zero results, which were below measurable minimum values (< 0.2 ppm).

182

Detailed test conditions are summarized in Table 2. The urea injection strategies in terms of

183

injection timings and mass were designed by the manufacturer. In the present system, the urea

184

injection system was used without any modification, which performed the same injection

185

strategies under different urea concentrations. Various urea concentrations were used to

186

investigate the effects of urea on DeNOx performance. The reference concentration was

187

32.5% m/m and other tested urea solutions were 20% and 40%. The test urea solutions were

188

obtained by mixing solid urea and distilled water based on mass fractions.

189

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 10 of 34 10

190

3. Results and discussion

191

This section presents the experimental results of the test engine under official conditions

192

to validate the engine system under EURO VI regulations. With this regard, various nitrogen

193

species within the exhausted emissions were investigated under a new set of testing

194

conditions, using different urea concentrations.

195

3.1 Emission results of official test modes

196

The test engine was evaluated to determine acceptability within EURO VI regulations

197

under the official WHTC and WHSC cycle modes. Emissions in terms of CO, THC, NOx,

198

NH3, and PM were measured using certified instruments. In this test, the emission results of

199

the WHTC cycle were obtained by integrating the cold and hot mode results based on a

200

weighting factor. Table 3 presents the final emissions concentrations for the two test modes,

201

compared to the EURO VI emissions standards. The emission values from the test engine

202

were within regulation limitations for each tested condition. With the employed after-

203

treatment system, engine emissions could be significantly reduced to below 10% of the limit

204

values with the exception of the nitrogen oxides. Although the SCR system was used to

205

reduce NOx emissions with high conversion efficiencies over 90%, the exhausted NOx

206

concentrations were close to the standard values in both modes that were tested. This

207

outcome accounted for the challenge of the DeNOx process with regard to engine-out

208

emissions.

209

3.2 NOx emissions for reference urea

210

For a profound investigation of nitrogen oxides, Figure 3 shows the conversion

211

efficiency of the reduction of NOx and its component species (NO, NO2 and N2O), while

212

comparing the upstream and downstream levels of the SCR DeNOx device. Upstream refers

ACS Paragon Plus Environment

Page 11 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 11

213

to the location prior to the after-treatment system. Downstream indicates the emissions

214

converted by the additional post-treatment devices. In general, the cold WHTC mode

215

produced a higher quantity of nitrogen oxides due to low exhaust temperatures, an important

216

factor in activating the SCR system. The new WHTC warm-up condition increased exhaust

217

temperatures up to 310oC, regarded as hot operation conditions. Thus, the total NOx

218

emissions for the WHTC decreased compared to that of the official WHTC mode. For raw

219

NOx emissions, the total quantity during steady-state driving mode was larger than during the

220

transient condition and was strongly related to the driving schedule (Fig. 2), as shown in Figs.

221

4 and 5. Although there was a difference in the quantity of NOx exhausted between the two

222

test modes, the conversion rates were around 96% for both conditions using the reference

223

urea. Interestingly, the fraction of nitrogen species were changed after the catalytic process

224

occurred in the DeNOx apparatus. When NOx emissions were released directly from the

225

engine, nitric oxide occupied nearly the entirety of the emitted NOx. Nitrogen dioxide and

226

nitrous oxide comprised only around 5–7% although they were summed. However, catalytic

227

reactions reduced the NO component by up to 9.8% and increased the fraction of N2O by

228

87.5% in the WHSC mode.

229

Figures 4 and 5 present the variation of each nitrogen component emission as a function

230

of time. The QCL analyzer simultaneously measured NO, NO2, N2O, and NH3 emissions in

231

real time. In Figs. 4(a) and 5(a), nitric oxide was predominantly exhausted at the exit of the

232

engine. In addition, the variation in concentration followed the torque movement for each test

233

mode as shown in Fig. 2. These results showed that engine torque was a significant factor in

234

generating NOx emissions. According to the extended Zeldovich mechanism, nitric oxide

235

formation depended highly on the temperature of the engine

236

increased, combustion temperatures and pressures were also elevated within the engine

237

cylinder. Moreover, higher quantities of NO were produced during WHSC driving because

ACS Paragon Plus Environment

21

. When the engine torque

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 34 12

238

the engine sustained higher load conditions for a while. This evidence was also observed in

239

the exhaust temperature graph in Figs. 4 and 5. As the engine load reached high states, the

240

engine-out temperature achieved high values. With regard to nitrogen dioxide, small fractions

241

were occupied in the NOx emissions for both modes. The mechanism for NO2 production was

242

the following:

243

(5)

244

Since HO2 radicals formed in relatively low-temperature conditions, the formation of

245

NO2 would be accelerated during low load conditions 22. Thus, the NO2 concentration under

246

the WHTC mode increased slightly compared to that of the WHSC mode. Although NO2

247

emissions play a negative role in the environment due to acid rain and photochemical smog,

248

NO2 promotes the catalytic reaction to reduce NO in the SCR system 5, 23. The toxic gas, NO2,

249

was consumed completely during post-processing in the DeNOx system.

250

In Figs. 4(b) and 5(b), it is remarkable that nitrous oxides, secondary emissions, were

251

increased, removing engine-out NO emissions via the after-treatment system. Although the

252

absolute value of N2O formation was low, the fraction increased considerably up to 87.5% in

253

the WHSC cycle. These results announced that mobile SCR system could induce GHG

254

emissions as opposed to significantly reducing NO. There are potential pathways to form

255

nitrous oxide in the urea-SCR system:

256

(6)

257

(7)

258

Equations (6) and (7) were reported by Colombo et al.

15

and Madia et al.

24

,

259

respectively. This result could happen if the NO2 content exceeds the NO levels in the

260

reactant gases. Another possible reaction is the partial oxidation of ammonia:

ACS Paragon Plus Environment

Page 13 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 13

261

(8)

262

In the copper zeolite catalyst, the oxidation of ammonia started between 250 and 300oC

263

and ammonia conversion was accelerated at higher temperatures of over 400oC 15. During the

264

ammonia oxidation process, N2O gas could be produced through partial oxidation. In the

265

present study, it was believed that the partial oxidation of ammonia was predominant in

266

forming nitrous oxide due to the high nitric oxide concentrations at the inlet. This conclusion

267

was clearly observed in the next section. As the urea concentration increased, the exhausted

268

N2O also increased. A relationship between the inlet gas temperature and N2O concentration

269

was discovered in Figs. 4(b) and 5(b). Nitrous oxide increased with a decrease in exhaust

270

temperatures. Moreover, increased temperatures suppressed the formation of nitrous oxide. It

271

seemed that the temperature decrease led to the partial oxidation of ammonia, resulting in a

272

larger quantity of N2O emissions. With regard to ammonia slip, the concentrations of NH3

273

was strongly related to the injection quantity of urea solution over the driving modes. The

274

largest amount of ammonia slip was observed under the WHSC mode between 1200s and

275

1300s, which was under the highest speed and torque conditions. The larger amount of urea

276

solution was injected to reduce the high NOx emissions with a short time. The instantly

277

injected urea which was not participated to the NOx conversion process was emitted to the

278

exhaust pipe. This operation period led the increase in the ammonia slip of WHSC mode

279

compared the WHTC mode as shown in Table 4.

280

3.3 Nitrogen oxide emissions for various urea concentration

281

The effects of urea concentration on SCR performance were investigated using two

282

tested urea agents with concentrations of 20% (m/m) and 40% (m/m). The engine test

283

conditions were the same as those of the previous reference test. Table 4 shows the nitrogen

284

oxides and ammonia slip at the final tail pipe, after being processed through the after-

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 34 14

285

treatment devices. The standard values refer to the official EURO VI limitations. With regard

286

to NOx emissions, the conversion efficiency increased with an increase in the concentration

287

of urea. With the 20% urea agent, the NOx emissions exceeded the standard values by more

288

than three times. Since the lower urea concentration supplied a smaller quantity of ammonia

289

reactant to the catalyst, the conversion rates deteriorated. Conversely, the 40% agent induced

290

the lowest NOx emissions values, which were half that of the reference values. The ammonia

291

slip, however, surpassed the standard values due to an excess of supply. Figure 6 illustrated

292

the composition fraction of nitrogen oxides after the DeNOx process. Engine-out meant that

293

raw emissions were measured prior to the SCR system. The total values were normalized to

294

the raw emission concentration.

295

Comparing the 20% and 40% agents, there were remarkable results with regard to the

296

fraction of nitrogen species. The portion of nitrogen dioxide increased in the low

297

concentration case, whereas the high concentration agent converted NO2 to near zero levels.

298

The increased in nitrogen dioxide originated from the NO oxidation reaction in the copper

299

zeolite system (9).

300

(9)

301

In general, the produced NO2 was used to convert nitric oxide with NH3. Due to

302

deficiencies in the ammonia component, a larger quantity of NO2 gas was exhausted with

303

unconverted NO emissions. For nitrous oxide emissions, they were also influenced by the

304

NH3 concentration. As mentioned above, the formation of N2O was primarily due to the

305

partial oxidation of ammonia. Thus, the 40% urea case exhausted the greatest fraction of N2O

306

gas although the total quantity of gas was significantly reduced by the high conversion

307

efficiency of the SCR. Figure 7 shows the nitrogen species concentrations as a function of

308

test times at the downstream of the SCR. For 20% urea solution in Fig. 7(a), the nitrogen

ACS Paragon Plus Environment

Page 15 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 15

309

dioxide concentration was high during the entire cycle period with low conversion rate of NO.

310

This results were caused by the lack of ammonia species in the SCR system as the

311

aforementioned it. In the WHTC mode, a larger amount of NO2 was measured with extremely

312

low N2O emissions. Under the high percentage of urea solution (40%), the conversion rate of

313

NO was dramatically increased compared to the standard urea agent (32.5%). The nitrous

314

oxide was formed with around 24% more concentration during the test time than that of the

315

32.5% urea solution.

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 34 16

316

4. Conclusion

317

Among the exhaust emissions of a heavy-duty engine, nitrogen oxide was profoundly

318

investigated based on the recent EURO VI emission regulations. Theoretically, it is well-

319

known that the nitric oxide and nitrogen dioxide that constitute NOx emissions are due to

320

transportation. However, this study experimentally showed the effects of a selective catalytic

321

reduction system on the fraction of nitrogen components in exhaust emissions. A quantum–

322

cascade laser (QCL) analyzer allowed each nitrogen–species (NO, NO2, N2O and NH3) to be

323

measured with high accuracy. Using three urea concentrations, nitrogen oxides and ammonia

324

slip were studied and the following conclusions were drwan:

325

1. For a EURO VI type engine, the mobile SCR system in a heavy–duty engine induced

326

a high NOx reduction rate of up to 96% under official steady-state and transient

327

driving cycles. The copper–zeolite catalyst converted the fraction of nitrogen oxides,

328

decreasing the total quantity of NOx emissions. During the catalytic reactions,

329

nitrous oxides were formed that occupied more than half the percentage of the NOx

330

exhaust emissions.

331

2. Although the absolute quantities of nitrous oxide are low, nitrous oxide can induce

332

greenhouse effects and smog in the city air. The heavy–duty engine primarily

333

operated under highway conditions for long-distance public transportations or cargo

334

trucks. Under steady–state conditions, the formation of N2O gas increased compared

335

to the transient driving case.

336

3. N2O production was proportional to an increase in the urea agent concentration. The

337

partial oxidation of ammonia was a main reaction in the formation of nitrous oxides.

338

When 40% urea was used in the SCR device, the fraction of N2O emissions

ACS Paragon Plus Environment

Page 17 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 17

339

increased by up to 93%. Moreover, an oversupply of ammonia induced a larger

340

amount of ammonia slip over the regulated values.

341 342

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 34 18

343

References

344

1. Hirata, K.; Masaki, N.; Ueno, H.; Akagawa, H., Development of Urea-SCR System for

345

Heavy-Duty Commercial Vehicles. SAE 2005, 2005-01-1860.

346

2. Girard, J. W.; Montreuil, C.; Kim, J.; Cavataio, G.; Lambert, C., Technical Advantages of

347

Vanadium SCR Systems for Diesel NOx Control in Emerging Markets. SAE Int. J. Fuels Lubr.

348

2008, 1, (1), 488-494.

349

3. Ku, K. W.; Hong, J. G.; Park, C. W.; Chung, K. Y.; Sohn, S. H., Effects of Various Factors

350

on the Conversion Efficiency of Urea Solution in a Urea Selective Catalytic Reduction

351

System. Energy Fuels 2014, 28, (9), 5959-5967.

352

4. Johnson, T. V., Diesel Emission Control in Review. SAE Int. J. Fuels Lubr. 2009, 2, (1), 1-

353

12.

354

5. Koebel, M.; Elsener, M.; Kleemann, M., Urea-SCR: a promising technique to reduce NOx

355

emissions from automotive diesel engines. Catal. Today 2000, 59, (3-4), 335-345.

356

6. Scott Sluder, C.; Storey, J. M. E.; Lewis, S. A.; Lewis, L. A., Low Temperature Urea

357

Decomposition and SCR Performance. SAE 2005, 2005-01-1858.

358

7. Grossale, A.; Nova, I.; Tronconi, E.; Chatterjee, D.; Weibel, M., NH3-NO/NO2 SCR for

359

Diesel Exhausts Aftertreatment: Reactivity, Mechanism and Kinetic Modelling of

360

Commercial Fe- and Cu-Promoted Zeolite Catalysts. Top. Catal. 2009, 52, (13-20), 1837-

361

1841.

362

8. Ruggeri, M. P.; Nova, I.; Tronconi, E., Experimental Study of the NO Oxidation to NO2

363

Over Metal Promoted Zeolites Aimed at the Identification of the Standard SCR Rate

364

Determining Step. Top. Catal. 2013, 56, (1-8), 109-113.

365

9. Maunula, T.; Viitanen, A.; Kinnunen, T.; Kanniainen, K., Design of Durable Vanadium -

366

SCR Catalyst Systems for Heavy - Duty Diesel Applications. SAE 2013, 2013-01-09.

367

10. Shan, W.; Liu, F.; He, H.; Shi, X.; Zhang, C., An environmentally-benign CeO2-TiO2

ACS Paragon Plus Environment

Page 19 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 19

368

catalyst for the selective catalytic reduction of NOx with NH3 in simulated diesel exhaust.

369

Catal. Today 2012, 184, (1), 160-165.

370

11. Fang, H. L.; DaCosta, H. F. M., Urea thermolsis and NOx reduction with and without

371

SCR catalysts. Appl. Catal., B 2003, 46, (1), 17-34.

372

12. Xu, L. F.; McCabe, R. W.; Hammerle, R. H., NOx self-inhibition in selective catalytic

373

reduction with urea (ammonia) over a Cu-zeolite catalyst in diesel exhaust. Appl. Catal., B

374

2002, 39, (1), 51-63.

375

13. De-La-Torre, U.; Pereda-Ayo, B.; Moliner, M.; Gonzalez-Velasco, J. R.; Corma, A., Cu-

376

zeolite catalysts for NOx removal by selective catalytic reduction with NH3 and coupled to

377

NO storage/reduction monolith in diesel engine exhaust aftertreatment systems. Appl. Catal.,

378

B 2016, 187, 419-427.

379

14. Grossale, A.; Nova, I.; Tronconi, E., Study of a Fe-zeolite-based system as NH3-SCR

380

catalyst for diesel exhaust aftertreatment. Catal. Today 2008, 136, (1-2), 18-27.

381

15. Colombo, M.; Nova, I.; Tronconi, E., A comparative study of the NH3-SCR reactions

382

over a Cu-zeolite and a Fe-zeolite catalyst. Catal. Today 2010, 151, (3-4), 223-230.

383

16. Kamasamudram, K.; Currier, N.; Szailer, T.; Yezerets, A., Why Cu- and Fe-Zeolite SCR

384

Catalysts Behave Differently At Low Temperatures. SAE Int. J. Fuels Lubr. 2010, 3, (1), 664-

385

672.

386

17. Luo, J.-Y.; Hou, X.; Wijayakoon, P.; Schmieg, S. J.; Li, W.; Epling, W. S., Spatially

387

resolving SCR reactions over a Fe/zeolite catalyst. Appl. Catal., B 2011, 102, (1-2), 110-119.

388

18. Misra, C.; Collins, J. F.; Herner, J. D.; Sax, T.; Krishnamurthy, M.; Sobieralski, W.;

389

Burntizki, M.; Chernich, D., In-Use NOx Emissions from Model Year 2010 and 2011 Heavy-

390

Duty Diesel Engines Equipped with Aftertreatment Devices. Environ. Sci. Technol. 2013, 47,

391

(14), 7892-7898.

392

19. Myung, C.-L.; Ko, A.; Kim, J.; Choi, K.; Kwon, S.; Park, S., Specific engine performance

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 34 20

393

and gaseous emissions characteristics of European test cycle and worldwide harmonized

394

driving cycle for a heavy-duty diesel engine. J. Mech. Sci. Technol. 2013, 27, (12), 3893-3902.

395

20. Guo, J.; Ge, Y.; Hao, L.; Tan, J.; Peng, Z.; Zhang, C., Comparison of real-world fuel

396

economy and emissions from parallel hybrid and conventional diesel buses fitted with

397

selective catalytic reduction systems. Appl. Energy 2015, 159, 433-441.

398

21. Heywood, J. B., Internal Combustion Engine Fundamentals. McGraw-Hill: New York,

399

1988.

400

22. Turns, S. R., An Introduction to Combustion: Concepts and Applications. McGraw-Hill:

401

New York, 2012.

402

23. Koebel, M.; Elsener, M.; Krocher, O.; Schar, C.; Rothlisberger, R.; Jaussi, F.; Mangold,

403

M., NOx reduction in the exhaust of mobile heavy-duty diesel engines by urea-SCR. Top.

404

Catal. 2004, 30-1, (1-4), 43-48.

405

24. Madia, G.; Koebel, M.; Elsener, M.; Wokaun, A., Side reactions in the selective catalytic

406

reduction of NOx with various NO2 fractions. Ind. Eng. Chem. Res. 2002, 41, (16), 4008-

407

4015.

408

ACS Paragon Plus Environment

Page 21 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 21

409

Acknowledgement

410

This work supported by the National Research Foundation of Korea (NRF), funded by the

411

Korea government (MSIP) (NRF-2013R1A1A2074615).

412

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 34 22

413

List of Tables

414

Table 1 Test engine specifications

415

Table 2 Test mode descriptions

416

Table 3 Formal mode results of test engine for EURO VI regulation

417

Table 4 Nitrogen oxides and ammonia slip concentrations under various urea

418

concentration

419

ACS Paragon Plus Environment

Page 23 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 23

420

421

Table 1 Test engine specifications Description

Value

Displacement (Liter)

12.7

Rated power (kW/rpm)

323.6/1800

Max. net torque (Nm/rpm)

2099/1200

Idle speed (rpm)

500

Intake system

Turbocharger

Exhaust system

EGR

After-treatment devices

DOC, DPF, SCR, AOC

422

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 24 of 34 24

423 424

Table 2 Test mode descriptions Test mode

WHSC

WHTC

Test time

1895s

1800s

Warm-up

1210rpm – 50% load

1000 rpm – 40% load

condition

10min.

Up to 309oC at SCR-out

Repeat

3 times

Urea 20%

32.5%

40%

concentration 425

ACS Paragon Plus Environment

Page 25 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 25

426 427

Table 3 Formal mode results of test engine for EURO VI regulation CO

HC

NOx

NH3

PM

(g/kWh)

(g/kWh)

(g/kWh)

(ppm)

(g/kWh)

0.664

0.026

0.394

0.6

0.005

4.000

0.160

0.460

10.0

0.01

0.006

0.004

0.323

0.2

0.003

1.500

0.130

0.400

10.0

0.01

Emissions

WHTC Measurement WHTC Standard WHSC Measurement WHSC Standard 428

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 26 of 34 26

429 430

Table 4 Nitrogen oxides and ammonia slip concentrations under various urea concentration Urea

NOx (g/kWh)

NH3 (ppm)

concentration

WHSC

WHTC

WHSC

WHTC

20%

1.224

1.512

0.05

0.02

32.5%

0.053

0.112

9.4

5.9

40%

0.025

0.039

24.1

15.4

Standard

0.400

0.460

10.0

10.0

431

ACS Paragon Plus Environment

Page 27 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 27

432

List of Figures

433

Figure 1 Schematic of heavy-duty diesel engine and emission measurement system

434

Figure 2 Speed and torque data for WHSC and WHTC driving schedules

435

Figure 3 Comparing nitrogen oxides concentrations by converting SCR system under

436

two test cycles

437

Figure 4 Nitrogen compounds concentration and exhaust temperature under WHSC

438

mode at (a) upstream and (b) downstream of SCR device

439

Figure 5 Nitrogen compounds concentration and exhaust temperature under WHTC

440

mode at (a) upstream and (b) downstream of SCR device

441

Figure 6 Normalized NOx concentrations for 20% and 40% test urea under (a) WHSC

442

and (b) WHTC modes

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 28 of 34 28

443

444 445

Figure 1 Schematic of heavy-duty diesel engine and emission measurement system

ACS Paragon Plus Environment

Page 29 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 29

446

447 448

Figure 2 Speed and torque data for WHSC and WHTC driving schedules

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 30 of 34 30

449

450 451 452

Figure 3 Comparing nitrogen oxides concentrations by converting SCR system under two test cycles

ACS Paragon Plus Environment

Page 31 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 31

453

454 455

(a) Upstream of WHSC

456 457

(b) Downstream of WHSC

458 459

Figure 4 Nitrogen compounds concentration and exhaust temperature under WHSC mode at (a) upstream and (b) downstream of SCR device

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 32 of 34 32

460

461 462

(a) Upstream of WHTC

463 464

(b) Downstream of WHTC

465 466

Figure 5 Nitrogen compounds concentration and exhaust temperature under WHTC mode at (a) upstream and (b) downstream of SCR device

ACS Paragon Plus Environment

Page 33 of 34

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels 33

467

468 469

(a) WHSC mode

470 471

(b) WHTC mode

472 473

Figure 6 Normalized NOx concentrations for 20% and 40% test urea under (a) WHSC and (b) WHTC modes

474

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 34 of 34 34

475 476

(a) WHSC mode

477 478

(b) WHTC mode

479 480

Figure 7 Nitrogen compounds concentration for 20% and 40% urea solutions at downstream of SCR under (a) WHSC and (b) WHTC modes

ACS Paragon Plus Environment