Nondestructive Profilometry of Optical Nanofibers - Nano Letters (ACS

Nov 10, 2016 - Single-mode optical nanofibers are a central component of a broad range of applications and emerging technologies. Their fabrication ha...
0 downloads 0 Views 6MB Size
Subscriber access provided by United Arab Emirates University | Libraries Deanship

Communication

Non-destructive profilometry of optical nanofibres Lars Skovgaard Madsen, Christopher Baker, Halina Rubinsztein-Dunlop, and Warwick Bowen Nano Lett., Just Accepted Manuscript • DOI: 10.1021/acs.nanolett.6b02460 • Publication Date (Web): 10 Nov 2016 Downloaded from http://pubs.acs.org on November 13, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Nano Letters is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Non-destructive profilometry of optical nanofibres Lars S. Madsen,∗ Christopher Baker, Halina Rubinsztein-Dunlop, and Warwick P. Bowen Centre for Engineered Quantum Systems, School of Mathematics and Physics, The University of Queensland, St. Lucia, Brisbane, Queensland 4072, Australia E-mail: [email protected]

Abstract Single-mode optical nanofibres are a central component of a broad range of applications and emerging technologies. Their fabrication has been extensively studied over the past decade, but imaging of the final sub-micrometre products has been restricted to destructive or low-precision techniques. Here we demonstrate an optical scattering-based scanning method that uses a probe nanofibre to locally scatter the evanescent field of a sample nanofibre. The method does not damage the sample nanofibre and is easily implemented only using the same equipment as in a standard fibre puller setup. We demonstrate sub-nanometre radial resolution at video rates (0.7 nm in 10 ms) on single mode nanofibres, allowing for a complete high-precision profile to be obtained within minutes of fabrication. The method thus enables non-destructive, fast and precise characterisation of optical nanofibers, with applications ranging from optical sensors and cold atom traps to non-linear optics. Keywords Optical nanofibres, nano profilometry, super-resolution imaging, evanescent field, nearfield imaging, nanophotonics

Optical nanofibres (ONFs) offer a wide variety of applications, ranging from optical sensors to nonlinear components and couplers to plasmonic and optomechanical systems [see 1 and references herein]. They also form the basis for emerging experimental platforms within cold atom physics 2–7 as well as in nano- and bio-particle detection. 8–10 The workhorse in these experiments is the intense evanescent optical field extending out of the optical nanofiber. For instance, these fields have allowed the generation of optical potentials for trapping cold atoms with a single atom optical depth as high as a few percent; 3 while in nano- and bio-imaging, trapping and detection of 5 nm silica particles and 4 nm bio-molecules in solution has been achieved. 10 In such applications, a uniform evanescent field is often required in order to ensure constant interaction strength over the length of the ONF. Several techniques are available to fabricate high

transmission ONFs, based on heating and pulling or etching a standard step index optical fibre. 11–15 For the heat-based methods, the theory describing the average resulting fibre shape is well understood 16 and likewise is the relationship between the shape and the transmission. 17 Experimentally ONFs with transmission greater than 99% have been demonstrated. 11–13 Often however, fluctuations in the fabrication process are responsible for deviations from the desired shape. Fluctuations occurring early in the pulling process affect the optical transmission and can thus be identified directly during fabrication. On the other hand, fluctuations occurring later in the process can lead to an inhomogeneous evanescent field, without appreciably affecting the overall transmission levels, making them difficult to identify. The general approach to characterise the evanescent field of an ONF has been to image the diameter of the ONF along its length. Imaging of

ACS Paragon Plus Environment

1

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

the ONFs with standard microscopy techniques is difficult since the ONF diameter is comparable to the diffraction limit. Scanning electron microscopy (SEM) can give very high resolution in both the radial and the axial directions, but it is challenging to use the technique without damaging the ONF. SEM images have been used to determine the statistical reproducibility of the fabrication methods and generally show that ONFs are structured with variations in diameter of several percent. 3,4,15,18–20 The SEM images are generally taken sparsely along the ONFs as continuous imaging of a millimetre long ONFs would require several hundred images per millimetre. Due to the limitations of SEM imaging a variety of alternative methods have been employed to image ONFs. 20–27 Early work by Sumetsky et al. demonstrated that the ONF radius could be determined with nanometre resolution by scanning a partly stripped fibre through its evanescent field and measuring its the transmission. 25 The method was limited by drag between the probe fibre (125 µm radius) and the sub-wavelength ONF and relied upon SEM images for calibration, hindering widespread application. 26 Later approaches to measure ONFs include stress strain analysis, nonlinear higher frequency generation, scanning nearfield optical microscopy, use of microcavities and analysis of multimode interference patterns. 20–24,26,27 In this paper we return to the idea of measuring transmission with a scatterer placed in the evanescent field of a sample ONF. We overcome the problem of drag by using microfibres as probe fibres. Further, we find that the multimode behavior in the tapered section provides a mean for absolute calibration of the radius eliminating the need for SEM images and thus making the method fully nondestructive. The technique is easily incorporated in standard heat-and-pull setups and can be used independently of the ultimate application. In practice, images of millimetre long ONFs can be obtained within a few minutes of fabrication, allowing for immediate quality control. We obtain a radial resolution of 0.7 nm and an axial resolution of around 1 micron. We observe that even high transmission ONFs can have fluctuations of around 5% in their radius on length scales of tens of micrometres, adversely affecting the uniformity of the evanescent field.

Page 2 of 8

Figure 1: Illustration of the experimental setup. a) Artistic illustration. b) Experimental setup. Light from a 780 nm laser is split with a 50/50 beamsplitter (BS). Half of the light is measured for intensity stabilisation with a photodetector (PD) and half is coupled into the sample fibre. A second probe fibre is placed in contact with the sample and stepped horizontally along the waist while the transmission is monitored with a second photodetector (PD). The signals from the two photodetectors are digitized with a data acquisition system (DAQ). Our approach to obtain a profile of a nanofibre, referred to as the sample fibre, is to inject light into it and step a second tapered probe fibre along it with the two in contact while measuring the transmission, as shown in Figure 1. When the probe fibre is in the thin region of the sample fibre, where the evanescent field extends out into the surrounding air, a fraction of this light is scattered. By measuring the resulting reduction in transmission an estimate of the evanescent field intensity at the probe fibre position is obtained. Figure 2 a) shows an example of a transmission measurement when stepping the probe fibre along a sample fibre, with a 10 ms measurement time at each step and 0.2 µm step size (See Supporting Information for details). As expected, we see

ACS Paragon Plus Environment

2

Page 3 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

Figure 2: Transmission data. Normalised transmission measured as function of the probe fibre position along the sample "fibre 1". a) Full profile of the ONF region. Each of the data points is an average of 10 ms measurements with 100 kHz sampling rate. b) Zoom in on the region where the fibre becomes single mode. Measurement points have been connected as a guide to the eye. c) Zoom in on the large fluctuation near the waist. that far from the ONF region the probe has no effect on transmission. As the probe approaches the nanofibre section, the transmission drops to a minimum near 60% of its maximal value. On the slopes of the tapered region a periodic modulation is observed that dies out when the transmission decreases below 81%, as shown in the zoomed portion of the plot in Figure 2 b). We attribute this modulation to interference in the multimode section of the ONF caused by the difference in propagation constants between the fundamental and first higher order guided modes, as also observed by Hoffman et al. 24 At the point where the oscillation dies out and the fibre becomes single mode theory predicts the silica fibre radius to be 0.36λ , 28 providing a fixed point for absolute calibration between the measured transmission and the nanofibre radius. Unexpectedly the transmission in the central nanofibre region is not smooth. As can be seen in figure 2 c), the transmission is highly structured with a variation up to 7% over 30 µm along the ONF and finer structures giving rise to changes in transmission of around 1%. For applications re-

quiring a uniform evanescent field such as a cold atom trap this particular ONF would be non-ideal despite no obvious signs of defects during fabrication and 98% transmission. To quantify the relation between the ONF radius and the transmission measurements we develop a simple phenomenological model. ONFs can be modelled as step index fibres where the core is glass and the cladding is air. 28–30 This model predicts the fraction of optical power that is inside the ONF Pin (r) and the part which is contained in the evanescent field Pout (r) as function of the ONF radius r (See Supporting Information for details). To model the reduction in transmission T (r) caused by placing a probe fibre onto it, we assume that for a given probe a fixed fraction η of the power in the evanescent field is scattered from the guided mode so that: T (r) =

Pin (r) + (1 − η)Pout (r) , Ptotal (r)

(1)

where Ptotal (r) = Pin (r)+Pout (r) is the total power. The fraction of power outside the ONF at the point

ACS Paragon Plus Environment

3

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 8

Figure 3: Comparison with SEM measurements. a) The transmission data in Figure 2 is used to derive the fibre radius using Eqn 1 with η = 1.00; results shown with the red points. The black points mark the SEM data and the grey shading under the points is a guide to the eye. Each point is the average radius on one image. Inset: Red points show the average over 3 µm bins of transmission measurements as function of the SEM measured thickness. The blue line is modelled with η = 1.00. b) Zoom in on the region from a) near the waist with dense SEM imaging. The scan data is averaged in 3 µm bins centred at the SEM positions. c) 6 juxtaposed examples of the SEM images used to measure the sample fibre radius, each image covers 3 µm of the fibre and is averaged giving one black point. where the fibre becomes single mode is 19% so η = (1 − Tsm )/0.19 can be determined experimentally in situ for a given probe fibre by determining the transmission (Tsm ) at that point, as shown in Figure 2 b). We note that due to coupling between the inside and outside fields η can exceed unity, as discussed in the Supporting Information. To confirm that the observed structures in the evanescent field are indeed caused by fluctuations in the radius of the ONF we image the sample fibre with a scanning electron microscope (SEM). Evenly spaced images each covering 3 µm of the ONF were taken every 100 µm along the tapered region of the fibre, as well as closely spaced images covering the fibre continuously for 65 µm near the fibre waist. The width of the ONF on the SEM images is digitally recognised with a systematic uncertainty of ±10 nm, (as discussed in the Supporting Information). The data of each SEM image is averaged to obtain one measurement of radius and the optical scan data of Figure 2 is converted into a profile of the sample fibre radius using Eq. (1). Figure 3 a) shows the SEM data over-

layed with the sample radius derived from the optical scan method. Taking the mean of the optical scan data in bins corresponding to the position and size of the SEM images the two sets of data can be statistically compared, giving a correlation coefficient exceeding 0.99. While the model fits for the single mode region of the fibre it starts to deviate in the multimode region. We expect the deviation to be caused by the simplicity of our model which assumes the same fraction of the evanescent field to be scattered in both the single mode and the multimode region. A full model is beyond the scope of this paper. Figure 3 b) shows the region of the nanofibre which has been densely imaged with SEM together with the averaged bins of optical scan data. The optical scan data and the SEM data have an average offset of around 1 nm. The correlation coefficient in this region is 0.94 making it apparent that the small fluctuations in transmission are primarily caused by fluctuations in the radius of the ONF sample. To quantify the resolution and reproducibility of the technique we profile a second ONF in greater

ACS Paragon Plus Environment

4

Page 5 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

detail. First we profile the full tapered section and evaluate the radius, shown on Fig. 4 a). This second nanofibre is much more uniform than the first, even though both were fabricated with very similar procedure and both exhibit 98% transmission (See Supporting Information for details). This provides an example of why characterisation beyond the standard transmission measurements done during fabrication is essential to applications that rely on uniformity of the evanescent field. We scan both left to right and right to left and observe a 4 µm hysteresis, which we attribute to the drag between the sample and the probe. This hysteresis has been compensated for in both Fig 4 a) and b). Second we profile 0.6 mm of the central waist section 302 times in succession. During the measurement time of 4 hours the transmission drops a total of 2.1% which is comparable to what we would expect without profiling the fibre, emphasising the non-destructive nature of the method. To correct for this systematic drift we scale each trace to fix the transmission to the average of the right most 100 µm of data. As can be seen in Figure 4 b) the measured radius is highly reproducible. The structures along the ONF axis are smooth on a length scale of around 1 µm setting an upper bound on the axial resolution. The standard deviation of the transmission is 0.003 of an average transmission of 0.631, corresponding to radial resolution in a single 10 ms measurement of 0.7 nm. To test the applicability of the technique when changing the probe thickness the second ONF is imaged with different thicknesses of the probe fibre giving transmissions at the waist between 80% and 10% (See Supporting Information for details). Thicker probes are observed to provide significantly higher radial resolution, but the increased drag introduces irregular hysteresis effects. Deriving the radius of the ONF using Eq. 1 for different probe thicknesses gives consistent results for the radius in the waist region to within 5%. Finally we investigate the profile dependence on the input polarisation. The polarisation is observed to change the relative transmission by up to 10% at the waist (See Supporting Information). Maintaining a stable input polarisation during the experiment is therefore essential. We find that near identical ONF profiles are obtained, independent of input polarisation. This shows that our method

Figure 4: Data for statistical analysis of the technique. a) The radius derived from 4 full scans of the second sample with η = 0.82, left to right scans (red points) have been compensated for 4 µm of hysteresis relative to right to left scans (blue points). b) Data for the 302 scans near the waist of the fibre marked with grey points. The data has been compensated for hysteresis and scaled to fix the average of the 100 µm right most data points. The mean of all the scans is shown with the red line. is robust to the input polarisation and that the input polarisation remains stable in the experiment. Furthermore the method allows characterisation of the birefringence of the sample. When profiling the ONF with several polarisation inputs the birefringence in the ONF would modify the observed profiles (as discussed in the Supporting Information). The experiment thus shows that the characterised ONF has negligible birefringence. The axial and radial resolution obtained here is sufficient to characterise the evanescent field uniformity of current fabrication techniques. In future applications, if improved resolution is required,

ACS Paragon Plus Environment

5

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

the current limitations are mainly technical set by the laser noise and polarisation fluctuations in the fibre. Further intensity stabilisation, longer measurement time and polarisation sensitive detection could bring the sensitivity deeper into the subnanometre scale. A different approach to improving the resolution is to experiment with the probe. As shown thicker probes can give improved resolution, but at a cost of increased drag effects. Coating a thin probe fibre with a high contrast material could provide higher scattering without causing increased drag. The size of the structures in the nanofibre surfaces observed here is consistent with previous SEM studies of fibre surface quality. 3,4,15,18,19 The full profiles of ONFs show that these structures can cover the entire ONFs rather than being isolated incidents. Our technique facilitates future experiments to scrutinise the cause of these structures. In summary, we demonstrate a method for quick, precise and non-destructive characterisation of optical nanofibres. With this method a complete width profile of an optical nanofibre can be measured with sub-nanometre resolution within minutes of fabrication and independent of the fibres final application. The availability of easy and fast characterisation will allow highly uniform ONFs to be selected for atom trapping and nonlinear optics, bio sensors to be calibrated, and fabrication methods to be optimised.

Page 6 of 8

bane, Queensland 4072, Queensland, Australia. Notes The authors declare no competing financial interest.

ACKNOWLEDGMENTS This work was funded by the Australian Research Council through the Centre of Excellence for Engineered Quantum Systems (EQuS, CE110001013), and by the Air Force Office of Scientific Research and the Asian Office of Aerospace Research and Development. W.P.B. is supported by the Australian Research Council Future Fellowship FT140100650.

References (1) Tong, L.; Zi, F.; Guo, X.; Lou, J. Optics Communications 2012, 285, 4641–4647. (2) Vetsch, E.; Reitz, D.; Sagué, G.; Schmidt, R.; Dawkins, S.; Rauschenbeutel, A. Physical Review Letters 2010, 104, 203603. (3) Goban, A.; Choi, K.; Alton, D.; Ding, D.; Lacroûte, C.; Pototschnig, M.; Thiele, T.; Stern, N.; Kimble, H. Physical Review Letters 2012, 109, 033603. (4) Kato, S.; Aoki, T. Physical Review Letters 2015, 115, 093603.

ASSOCIATED CONTENT Supporting Information

(5) Béguin, J.-B.; Bookjans, E.; Christensen, S.; Sørensen, H.; Müller, J.; Polzik, E.; Appel, J. Physical Review Letters 2014, 113, 263603.

This material is available free of charge via the Internet at http://pubs.acs.org. Experimental methods, additional data and MATLAB code for generating lookup table.

(6) Gouraud, B.; Maxein, D.; Nicolas, A.; Morin, O.; Laurat, J. Physical Review Letters 2015, 114, 180503.

AUTHOR INFORMATION

(7) Lee, J.; Grover, J.; Hoffman, J.; Orozco, L.; Rolston, S. Journal of Physics B: Atomic, Molecular and Optical Physics 2015, 48, 165004.

Corresponding Author *E-mail: [email protected] Present Addresses

(8) Yu, X.-C.; Li, B.-B.; Wang, P.; Tong, L.; Jiang, X.-F.; Li, Y.; Gong, Q.; Xiao, Y.-F. Advanced Materials 2014, 26, 7462–7467.

Building 6, School of Mathematics and Physics, The University of Queensland, St. Lucia, Bris-

ACS Paragon Plus Environment

6

Page 7 of 8

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Nano Letters

(9) Swaim, J. D.; Knittel, J.; Bowen, W. P. Applied Physics Letters 2013, 103, 203111.

(22) Holleis, S.; Hoinkes, T.; Wuttke, C.; Schneeweiss, P.; Rauschenbeutel, A. Applied Physics Letters 2014, 104, 163109.

(10) Mauranyapin, N. P.; Madsen, L. S.; Taylor, M. A.; Waleed, M.; Bowen, W. P. arXiv:1609.05979

(23) Coillet, A.; Cluzel, B.; Vienne, G.; Grelu, P.; de Fornel, F. Applied Physics B 2010, 101, 291–295.

(11) Hoffman, J.; Ravets, S.; Grover, J.; Solano, P.; Kordell, P.; Wong-Campos, J.; Orozco, L.; Rolston, S. AIP advances 2014, 4, 067124.

(24) Hoffman, J. E.; Fatemi, F. K.; Beadie, G.; Rolston, S. L.; Orozco, L. A. Optica 2015, 2, 416–423.

(12) Ding, L.; Belacel, C.; Ducci, S.; Leo, G.; Favero, I. Applied Optics 2010, 49, 2441– 2445.

(25) Sumetsky, M.; Dulashko, Y.; Fini, J. M.; Hale, A.; Nicholson, J. W. Opt. Lett. 2006, 31, 2393–2395.

(13) Nagai, R.; Aoki, T. Optics express 2014, 22, 28427–28436.

(26) Sumetsky, M.; Dulashko, Y. Opt. Lett. 2010, 35, 4006–4008.

(14) Chenari, Z.; Latifi, H.; Ghamari, S.; Hashemi, R.; Doroodmand, F. Optics & Laser Technology 2016, 76, 91–95.

(27) Keloth, J.; Sadgrove, M.; Yalla, R.; Hakuta, K. Opt. Lett. 40, 4122–4125. (28) Le Kien, F.; Liang, J.; Hakuta, K.; Balykin, V. Optics Communications 2004, 242, 445–455.

(15) Tong, L.; Gattass, R. R.; Ashcom, J. B.; He, S.; Lou, J.; Shen, M.; Maxwell, I.; Mazur, E. Nature 2003, 426, 816–819.

(29) Snyder, A. W.; Love, J. Optical waveguide theory; Springer Science & Business Media, 2012.

(16) Birks, T. A.; Li, Y. W. Lightwave Technology, Journal of 1992, 10, 432–438. (17) Love, J.; Henry, W.; Stewart, W.; Black, R.; Lacroix, S.; Gonthier, F. Tapered singlemode fibres and devices. I. Adiabaticity criteria. 1991.

(30) Vetsch, E. Optical Interface Based on a Nanofiber Atom- Trap. Ph.D. thesis, Johannes Gutenberg-Universitt, 2010.

(18) Brambilla, G.; Finazzi, V.; Richardson, D. Optics Express 2004, 12, 2258–2263. (19) Garcia-Fernandez, R.; Alt, W.; Bruse, F.; Dan, C.; Karapetyan, K.; Rehband, O.; Stiebeiner, A.; Wiedemann, U.; Meschede, D.; Rauschenbeutel, A. Applied Physics B 2011, 105, 3–15. (20) Gusachenko, I.; Truong, V. G.; Frawley, M. C.; Chormaic, S. N. arXiv preprint arXiv:1506.01893 2015, (21) Wiedemann, U.; Karapetyan, K.; Dan, C.; Pritzkau, D.; Alt, W.; Irsen, S.; Meschede, D. Optics express 2010, 18, 7693–7704.

ACS Paragon Plus Environment

7

Nano Letters

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 ACS Paragon Plus Environment

8