Norovirus Dynamics in Wastewater Discharges ... - ACS Publications

Sep 20, 2016 - Ryhov County Hospital, Medical Services, Clinical Microbiology, ... of Clinical and Experimental Medicine, Medical Microbiology, SE-581...
0 downloads 0 Views 668KB Size
Subscriber access provided by TULANE UNIVERSITY

Article

Norovirus dynamics in wastewater discharges and in the recipient drinking water source: Long-term monitoring and hydrodynamic modelling Olaf Dienus, Ekaterina Sokolova, Fredrik Nyström, Andreas Matussek, Sture Löfgren, Lena Blom, Thomas J.R. Pettersson, and Per-Eric Lindgren Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.6b02110 • Publication Date (Web): 20 Sep 2016 Downloaded from http://pubs.acs.org on September 20, 2016

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 24

Environmental Science & Technology

1

Norovirus dynamics in wastewater discharges and in the recipient drinking water source: Long-

2

term monitoring and hydrodynamic modelling

3

Olaf Dienus 1, 2, Ekaterina Sokolova 3, *, Fredrik Nyström 1, 2, a, Andreas Matussek 1, Sture Löfgren 1,

4

Lena Blom 3, 4, Thomas J.R. Pettersson 3, Per-Eric Lindgren 1, 2

5

1

Ryhov County Hospital, Medical Services, Clinical Microbiology, SE-551 85 Jönköping, Sweden

6

2

Linköping University, Department of Clinical and Experimental Medicine, Medical Microbiology, SE-

7

581 85 Linköping, Sweden

8

3

9

Environment Technology, SE-412 96 Gothenburg, Sweden

Chalmers University of Technology, Department of Civil and Environmental Engineering, Water

10

4

11

Sweden

12

a

13

Resources Engineering, Architecture and Water, SE-971 87 Luleå, Sweden

14

* Corresponding author, e-mail: [email protected]; phone: +46 31 7721929

City of Gothenburg, Department of Sustainable Waste and Water, Box 123, SE-424 23 Angered,

Currently: Luleå University of Technology, Department of Civil, Environmental and Natural

15 16

Supporting Information. Details regarding the sampling programme, norovirus analyses,

17

hydrodynamic modelling, measured microbial concentrations in wastewater, simulated microbial

18

concentrations in source water.

19 20

1 ACS Paragon Plus Environment

Environmental Science & Technology

21

Abstract

22

Norovirus (NoV) that enters drinking water sources with wastewater discharges is a common cause

23

of waterborne outbreaks. The impact of wastewater treatment plants (WWTPs) on the river Göta älv

24

(Sweden) was studied using monitoring and hydrodynamic modelling. The concentrations of NoV

25

genogroups (GG) I and II in samples collected at WWTPs and drinking water intakes (source water)

26

during one year were quantified using duplex real-time reverse-transcription PCR. The mean

27

(standard deviation) NoV GGI and GGII genome concentrations were 6.2 (1.4) and 6.8 (1.8) in

28

incoming wastewater, and 5.3 (1.4) and 5.9 (1.4) Log10 genome equivalents (g.e.) L-1 in treated

29

wastewater, respectively. The reduction at the WWTPs varied between 0.4 and 1.1 Log10 units. In

30

source water, the concentration ranged from below the detection limit to 3.8 Log10 g.e. L-1. NoV GGII

31

was detected in both wastewater and source water more frequently during the cold than the warm

32

period of the year. The spread of NoV in the river was simulated using a three-dimensional

33

hydrodynamic model. The modelling results indicated that the NoV GGI and GGII genome

34

concentrations in source water may occasionally be up to 2.8 and 1.9 Log10 units higher, respectively,

35

than the concentrations measured during the monitoring project.

36

Key words: Göta älv; E. coli; norovirus; somatic coliphages; sewage; real-time PCR; water quality.

37

1 Introduction

38

Human norovirus (NoV) is highly infectious.1-2 NoV spreads rapidly through person-to-person contact,

39

airborne droplets, and water and food.1 Immunity after the disease is incomplete and short-lived,3

40

thus repeated infections of the same agent are common. Stool from infected individuals contains 105

41

to 1012 NoV per gram.4 Viruses are generally resistant to current methods of wastewater treatment

42

and often remain infectious for a long time in the environment.5 Thus, wastewater discharges to

43

drinking water sources pose risks of waterborne disease outbreaks.6-7

2 ACS Paragon Plus Environment

Page 2 of 24

Page 3 of 24

Environmental Science & Technology

44

NoV is one of the most common causes of nonbacterial waterborne outbreaks of gastroenteritis in all

45

age groups.8 One of the largest waterborne NoV gastroenteritis outbreaks in Sweden in recent years

46

occurred in the municipality of Lilla Edet in 2008, with approximately 2400 cases. It was suspected

47

that the cause of the outbreak was the contamination of the drinking water source – the river Göta

48

älv.9

49

Traditionally, microbial water quality control is based on detection of faecal indicator

50

microorganisms, e.g. E. coli, coliforms, and coliphages. However, there is a lack of correlation

51

between the concentrations of faecal indicator bacteria and specific pathogens, such as NoV.10-12 Yet,

52

there are contradictory reports regarding the correlation between the concentrations of somatic

53

coliphages and NoV in source water.11, 13 Thus, traditional water quality monitoring may not fully

54

predict the health risks.14

55

Little is known about the concentrations of NoV in source water, but this information is crucial for

56

the assessment of health risks for drinking water consumers.15 Molecular methods, like reverse

57

transcription – quantitative polymerase chain reaction (RT-qPCR) with a high sensitivity for detection

58

of NoV in water,16 have the potential to provide this information.

59

Microbial water quality can also be studied by hydrodynamic models, which simulate the spread of

60

faecal contamination in a water source. Hydrodynamic modelling can be used to describe the

61

temporal and spatial variability of microbial concentrations,17 to study the influence of different

62

processes on the microbial water quality,18 and to quantify the relative impact of different faecal

63

sources.19 In addition, this approach can be used to quantify the concentrations that are below the

64

detection limits of analytical methods, yet still high enough to be relevant to consumer health.20

65

The aim of this study was to determine the seasonal dynamics of NoV in wastewater and in the

66

recipient drinking water source – the river Göta älv in Sweden. For this purpose, the concentrations

67

of NoV and faecal indicators E. coli and somatic coliphages were (i) measured during long-term

68

monitoring, and (ii) simulated by means of hydrodynamic modelling. 3 ACS Paragon Plus Environment

Environmental Science & Technology

69

2 Methods

70

2.1 Study area

71

Göta älv is a river that drains Lake Vänern into the strait Kattegat at the city of Gothenburg on the

72

west coast of Sweden (Figure S1). The total catchment area of the river Göta älv is 50 233 km2, which

73

constitutes approximately 10 % of the area of Sweden. The part of the catchment area that is located

74

downstream of Lake Vänern is approximately 3500 km2. The length of the river between the outflow

75

from Lake Vänern and the mouth of the river is 93 km. The vertical drop of the river is approximately

76

44 m. The water flow in the river Göta älv is regulated by several hydropower stations (Figure S1) and

77

varies strongly; the mean and the maximum water flows are 550 and 1000 m3 s-1, respectively. The

78

transport time between the outflow from Lake Vänern and the mouth of the river is between 1.5 and

79

5 days.

80

The river is used as a water source for the drinking water supply of 700 000 consumers in several

81

municipalities, including Gothenburg with 500 000 consumers. Between Lake Vänern and the water

82

intake for the city of Gothenburg (Figure S1) the river receives wastewater from approximately 100

83

000 persons. Approximately 95 % of this wastewater is treated at municipal wastewater treatment

84

plants (WWTPs), while 5 % is treated by on-site sewer systems.

85

2.2 Sampling

86

Source water samples (n=58) were collected from five drinking water treatment plants (DWTPs)

87

along the river: Skräcklan in Vänersborg, Överby in Trollhättan, Lilla Edet, Dösebacka in Kungälv, and

88

Lärjeholm in Gothenburg (Figure S1). Wastewater samples (n=160) were collected from four WWTPs:

89

Holmängen in Vänersborg, Arvidstorp in Trollhättan, Ellbo in Lilla Edet, and Ryaverket in Gothenburg

90

(Figure S1).

91

Sampling was conducted during one year, from 8 June 2011 to 5 June 2012 (Table S1). Source water

92

samples were collected as 10.5 L grab samples of the incoming water at the DWTPs. Wastewater 4 ACS Paragon Plus Environment

Page 4 of 24

Page 5 of 24

Environmental Science & Technology

93

samples were collected at the WWTPs continuously for 24 hours using automatic flow rate controlled

94

samplers; 1.5 L was used for further analyses. The 24 hour sampling was done to compensate for

95

fluctuations in concentration. All samples were collected in sterile glass containers and kept at 4 °C

96

until analysis. From each sample, 0.5 L was used for faecal indicator analyses.

97

2.3 Norovirus analyses

98

In this study, NoV genogroups (GG) I and II were studied. NoV genome concentrations were analysed

99

at the Microbiology Laboratory, Medical Services, County Hospital Ryhov, Jönköping. The details

100

regarding enrichment from source water and wastewater, extraction of RNA and reverse

101

transcription, detection and quantification by TaqMan real-time PCR, and controls of the

102

methodology are described in supporting information.

103

For source water, the limit of quantification (LOQ) was 3.8×101 g.e. L-1, and the limit of detection

104

(LOD) was extrapolated to 1.1×101 g.e. L-1. For wastewater, the LOQ was 1.5×104 g.e. L-1, and the LOD

105

was extrapolated to 4.5×103 g.e. L-1.

106

To control virus enrichment and RNA extraction steps, the samples were spiked with murine

107

norovirus 1 solution (MNV-1). The recovery rate was estimated for each sample using quantitative

108

real-time PCR for MNV-1. Inhibition control of the reverse transcription step was done with Alien

109

Reference RNA VIC QRT-PCR Detection Kit. To rule out PCR inhibition and to optimise PCR

110

performance, tick-borne encephalitis virus (TBEV) was used.

111

The process control MNV-1 showed that the virus recovery rate varied between 1.2 % and 23 % with

112

a mean of 18 % for source water, and between 0.1 % and 31 % with a mean of 5 % for wastewater.

113

All reported concentrations were corrected for the recovery rate. Inhibition control of the reverse

114

transcription step showed no inhibition. The PCR inhibition control TBEV showed no inhibition.

5 ACS Paragon Plus Environment

Environmental Science & Technology

115

2.4 Faecal indicator analyses

116

The concentrations of E. coli were analysed within four hours after sampling at ALcontrol AB,

117

Linköping, Sweden, according to the Swedish standard SS 028167-2 (membrane filtration method).

118

The concentrations of somatic coliphages were analysed on the sampling day at Lackarebäck

119

laboratory, Gothenburg, Sweden, according to the standard ISO 10705-2 (plaque assay method).

120

2.5 Statistical analyses

121

The measured data were Log10 transformed and analysed using t-tests and correlation analyses. To

122

analyse the seasonality of concentrations, the warm and cold periods were defined based on

123

whether the air temperature was above or below +10 °C, respectively. The warm period included 13

124

sampling occasions (8 Jun 2011 – 12 Oct 2011 and 9 May 2012 – 5 Jun 2012); and the cold period

125

included 14 sampling occasions (26 Oct 2011 – 25 Apr 2012). To compare the number of samples

126

above the LOD during the warm and cold periods, Fischer’s exact test was used. P-value