Performance of a Bench-Scale Fast Fluidized Bed Carbonator

Publication Date (Web): July 1, 2014 ... For a more comprehensive list of citations to this article, users are encouraged to perform a search inSciFin...
0 downloads 0 Views 596KB Size
Subscriber access provided by UZH Hauptbibliothek / Zentralbibliothek Zuerich

Article

Performance of a Bench Scale Fast Fluidized Bed Carbonator Sharat Kumar Pathi, Weigang Lin, Jytte Boll Illerup, Kim Dam-Johansen, and Klaus Hjuler Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/ef500572b • Publication Date (Web): 01 Jul 2014 Downloaded from http://pubs.acs.org on July 5, 2014

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 41

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Performance of a Bench Scale Fast Fluidized Bed Carbonator 1

Sharat K. Pathi 1

1

1

Jytte B. Illerup*

Kim Dam-Johansen 2

1

Weigang Lin

Klaus Hjuler

Department of Chemical and Biochemical Engineering, Technical University of Denmark, Building 229, DK-2800 Kgs. Lyngby, Denmark 2

FLSmidth A/S, DK-2500 Valby, Denmark

*Corresponding author: Jytte Boll Illerup; e-mail:- [email protected]

ACS Paragon Plus Environment

1

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 41

ABSTRACT The carbonate looping process is a promising technology for CO2 capture from flue gas. In this process the CO2 capture efficiency depends on the performance of a carbonator that may be operated as a Circulating Fluidized Bed (CFB). In this paper, the carbonator performance is investigated by applying a new experimental method with accurate control of the particle re-circulation rate. The experimental results show that the inlet calcium to carbon molar ratio is the main factor on the CO2 capture efficiency in the carbonator, i.e. increasing the inlet Ca/C from 4 to 13 results in increasing the CO2 capture efficiency from 40 to 85% with limestone having a maximum CO2 capture capacity of only 11.5%. Furthermore, a reactor model for carbonator is developed based on the Kunii-Levenspiel’s model. A key parameter in the model is the particle distribution along the height of the reactor, which is estimated from experiments under stable operating conditions with constant bed inventory, reactor temperature and exit CO2 concentration. The validated CFB carbonator model was used to simulate different operating conditions relevant for CO2 capture from a power plant and for a cement plant. The results show that particle re-circulation rates of 2-5 kg/(m2s) or ratio of bed inventory to re-circulation rates of 70-176 s are sufficient for attaining 90% CO2 capture efficiency depending on the inlet Ca to C ratio.

KEYWORDS: CCS, CO2 Capture, CFB carbonator, Carbonate Looping, Cement plant, Power plant

ACS Paragon Plus Environment

2

Page 3 of 41

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Nomenclature a [1 / m ] :

Solids distribution decay constant

At [m2 ] :

Cross sectional area of reactor

CCO2 ,in [kmol / m3 ] :

CO2 inlet concentration

CCO2 ,eq [kmol / m3 ] :

CO2 equilibrium concentration

CCO2 ,exit [kmol / m3 ] : CO2 exit gas concentration CCO2 ,d [kmol / m3 ] :

CO2 concentration in the dense bed

CCO2 ,l [kmol / m3 ] :

CO2 concentration in the freeboard

d p [mm] :

Particle size

D [m ] :

Reactor diameter 0.06 m

Ecarb,s [−] :

CO2 capture efficiency from solid conversion

Ecarb,g [−] :

CO2 capture efficiency from gas conversion

FCaO,in [kmol / s] :

Flow rate of CaO into carbonator

FCaO,out [kmol / s] :

Flow rate of CaO out of carbonator

FR [kmol / s] :

Flow rate of Ca into carbonator

Gs [kg / m2 ⋅ s] :

Particle re-circulation rate

hl [ m ] :

Location in the free board region

H d [m] :

Height of dense bed

ACS Paragon Plus Environment

3

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

H l [m ] :

Height of free board region

H t [m] :

Reactor height

k [ −] :

Sorbent decay constant

kcw [1 / s] :

Gas transfer co-efficient

k g [m / s ] :

Gas transfer constant

ks [m4 / kmol ⋅ s] :

Surface rate constant

kr [m3 / kmol ⋅ s] :

Effective rate constant

K r [1 / s ] :

Reactor rate constant

M i [kg / kmol ] :

Molar mass of component ‘i’

N [ −] :

Cycle number

R [ kJ / kmol ⋅ K ] :

Gas constant

So [m2 / m3 ] :

Initial specific surface area

Save [m2 / m3 ] :

Average specific surface area

t[ s ] :

Time

T [K ] :

Temperature

uo [ m / s ] :

Gas velocity

xCaO [−] :

Fraction of CaO in limestone

xCO2 ,in [vol.%] :

CO2 concentration in the inlet gas

xCO2 ,outlet [vol.%] :

CO2 concentration in the exit gas

ACS Paragon Plus Environment

Page 4 of 41

4

Page 5 of 41

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

X or X carb [ −] :

Average bed conversion

X cal [ − ] :

Fraction of CaCO3 in calcined limestone

X r [−] :

Residual CO2 capture capacity

X max [−] :

Maximum CO2 capture capacity

W [ kg ] :

Bed inventory

δ cd [ − ] :

Bubble or core region in dense bed

ε mf [−] :

Void fraction under minimum fluidization (0.4)

ε s [−] :

Solids fraction

ε sd [− ] :

Solids fraction in the dense bed

ε s*[−] :

Solids fraction under saturating gas carrying

ε sl [−] :

Solids fraction in the freeboard

ε se [ − ] :

Solids fraction at the reactor exit

ρ [kg / m3 ] :

calcined limestone density

η[−] :

Contact efficiency between gas and particles

ηd [ − ] :

Contact efficiency in the dense bed

ηl [− ] :

Contact efficiency in the freeboard

φCO ,in [ NL / min] :

Inlet CO2 flow rate

φCO ,out [ NL / min] :

Outlet CO2 flow rate

φt ,in [ NL / min] :

Fluidizing gas flow rate

CaO

2

2

ACS Paragon Plus Environment

5

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 41

1. Introduction One of the emerging technologies for CO2 capture from flue gas is the Carbonate Looping Process (CLP)1. The calcium based sorbent material is continuously circulated between two reactors, one for capturing CO2 from flue gas and the other for regeneration of the sorbent along with releasing CO2 gas 2-12

. The CLP is considered to have a large potential as an alternative to wet chemical processes

(amines), especially in terms of a lower energy penalty and corrosive material3. Other advantages of CLP are that abundantly available natural limestone can be used as sorbent, and that high-temperature streams are available for energy efficient co-generation. So this process is of special interest for combining CO2 capture simultaneously for power and cement production 13-15. Different aspects of the carbonate looping process has been investigated, such as particle scale studies12,

16, 17

, reactor scale studies18-21, process integration studies1,

6, 7, 14, 22

and techno-economic

evaluations23, 24. Using a thermo-gravimetric analyzer (TGA), the conversion of CaO to CaCO3 has been studied as function of the carbonation temperature, the inlet CO2 concentration, the calcination conditions, the type of limestone and the looping cycle number.12,

25-30

. However, these results are

difficult to apply directly to scaling up because the flow conditions in industrial scale reactors are completely different from the ideal conditions tested in TGA. A number of experimental facilities have been established recently in scales ranging from 10 kWth to 1.7 MWth as summarized in Table 1 (single fluidized beds) and Table 2 (dual fluidized beds). The reactor level studies have shown that the performance of the carbonator determines the overall efficiency of the carbonate looping process. The two main factors are 1) the maximum CO2 capture capacity of the calcined limestone, i.e. a particle structure related parameter31 and 2) the operating conditions of the carbonator. The particle scale studies were useful in determining the reaction rate which can be used in reactor models for simulating

ACS Paragon Plus Environment

6

Page 7 of 41

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

the influence of operating parameters. A brief literature review on the experimental work with single and dual fluidized bed reactors, as well as, the carbonator models is summarized as follows.

1.1 Single Fluidized Bed Results The setup with a single fluidized bed is normally used for cycling experiments. Table 1 summarizes the experimental conditions applied to investigate the carbonate looping process in single fluidized bed reactors along with reactor dimensions and scales. The general trend of the CO2 capture capacity as a function of cycle number is similar to TGA results. The results of cycle experiments in large pilot scale facility operated as a bubbling fluidized bed reactor by Galloy et al.20 indicated the reliability of the carbonate looping process for industrial applications. However, for industrial applications fast fluidized bed reactors with particle recirculation are probably more relevant for continuous operation with a lower footprint, and a more efficient mixing of particulates. Table 1: Cyclic experiments in a single fluidized bed reactor

INCAR KIER CANMET TUD

Hbed (HT)

D

Scale

dp

Calcination

Carbonation

[m]

[m]

[kWth]

[mm]

1 (5)

0.1

75

0.65-1.68

850°C, Air

650°C,15%CO2

0.2 (1.2)

0.1

n/a

0.35-0.6

850°C, Air

700°C,16%CO2

1 (5)

0.1

75

0.65-1.67

850°C,Air

700°C,15%CO2

1.2 (8.7)

0.6

470

0.43*

800°C,Air

700°C,15%CO2

Ref.

Abanades et al.18 Ryu et al.32 Salvador et al.33 Galloy et al. 20

*:Mean particle size; H is height of dense bed and H is total height of reactor. bed T

ACS Paragon Plus Environment

7

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 8 of 41

1.2 Dual Fluidized Bed Results The dual fluidized bed systems are used for investigating the carbonate looping process in continuous operation. Table 2 summarizes the dual fluidized bed facilities in open literature. The results in these studies show that the most important parameter in the process is the particle recirculation rate which was controlled by different methods. Some of these studies were carried out for parametric investigations while others for demonstrating the industrial applicability of the carbonate looping process. Table 2: Looping experiments in dual fluidized bed reactors Scale Particle recirculation rate

Hbed (HT)

D

Ref.

[kWth]

[kg/m2.s]

[m]

[m]

CANMET

75

n/a

1 (5)

0.1

Lu et al.19, 34

OSU

120

n/a

n/a

n/a

Wang et al.35

Tsinghua

10’s

0.8

0.3 (1)

0.15

Fan et al.36

IFK

10’s