Potential of Nanoparticle-Enhanced Ionic Liquids ... - ACS Publications

Sep 26, 2011 - Telephone: 803-507-8560. .... Review on system and materials requirements for high temperature thermal energy storage. .... L. Perez , ...
0 downloads 3 Views 680KB Size
COMMUNICATION pubs.acs.org/EF

Potential of Nanoparticle-Enhanced Ionic Liquids (NEILs) as Advanced Heat-Transfer Fluids Nicholas J. Bridges, Ann E. Visser, and Elise B. Fox* Savannah River National Laboratory, Aiken, South Carolina 29808, United States

bS Supporting Information ’ INTRODUCTION Interest in capturing the energy of the sun is rising as demands for renewable energy sources increase. One area of developing research is the use of concentrating solar power (CSP), where the solar energy is concentrated using mirrors to direct the sunlight toward a collector filled with a heat-transfer fluid (HTF).1 The HTF transfers the collected energy into pressurized steam, which is used to generate energy. The greater the energy collected by the HTF, the more efficient the electrical energy production; thus, the overall efficiency is controlled by the thermal fluid. Commercial HTFs, such as Therminol (VP-1), which is a blend of biphenyl and diphenyl oxide,2 have a significant vapor pressure, especially at elevated temperatures.1 For these volatile compounds to be used in CSP systems, the system has to be either engineered to prevent the phase change (i.e., volatilization and condensation) through pressurization of the system or operated across the phase change.3 Over 30 years ago, a class of low-melting organic compounds were developed with negligible vapor pressure.4 These compounds are referred to as ionic liquids (ILs), which are organicbased compounds with discrete charges that cause a significant decrease in their vapor pressure.5 As a class, ILs are molten salts with a melting point below 100 °C and can have a liquidus range approaching 400 °C and, in several cases, with freezing points being below 0 °C.6 Because of the lack of an appreciable vapor pressure, volatilization of an IL is not possible at atmospheric pressure,5 which would lead to a simplification of the design if used as a thermal fluid and for energy storage materials.7 Although the lack of a vapor pressure does not make the use of ILs a better HTF, the lack of a vapor pressure is a compliment to their higher heat capacity, higher volummetric density, and thus, higher volumetric heat capacity.8 These favorable physical properties give ILs a pontential advantage over the current commerically used thermal fluids. Also, within the past decade, nanofluids have gained attention for thermal conductivity enhancment of fluids,9 but little analysis has been completed on the heat capacity effects of the nanoparticle addition. The idea of ILs or nanofluids as a HTF is not new, because there are several references that have proposed the idea.8,10 However, the use of IL nanofluids containing nanomaterials other than carbon nanotubes has never before been studied. Here, for the first time, nanoparticle-enhanced ILs (NEILs) have been shown to increase the heat capacity of the IL with no adverse side effects to the thermal stability of ILs, and only at high nanoparticle loading, are the IL physical properties affected. An increase of the volumetric heat capacity translates into a better HTF because r 2011 American Chemical Society

more energy is stored per volumetric unit in the solar concentrating section, thus, more efficency in increased steam pressure. Results show that the properties of the NEIL are highly dependent upon the suspended nanomaterial and careful material selection is required to fully optimize the nanofluid properties.

’ RESULTS AND DISCUSSION Physical Properties. A good HTF needs to have the ability to absorb a significant amount of energy in a given volume, because the geometry is dictated by the system design. On the basis of this, the volumetric heat capacity, which is a function of the heat capacity and the density, is a very important physical property to evaluate the NEILs against the traditional volatile organic thermal fluid, in this case VP-1, and the neat ILs. 1-Butyl-2,3-dimethylimidazolium bis(trifluoromethylsulfonyl)imide ([C4mmim][NTf2]) was selected because it is commerially avaliable from a wide range of vendors and has a tolerable viscosity and good thermal stability.11 The methyl blocking of the C-2 proton should decrease the chances of a catalytic/carbene-like interaction12 with the nanoparticles with minimal effect on the viscosity. In Table 1, the heat capacity and density of [C4mmim][NTf2] and NEILs with 50 nm Al2O3 or 4 nm carbon black (CB) are compared at 80 and 200 °C. Plots of the heat capacity curves from 60 to 360 °C are available in the Supporting Information. Nanoparticle loading of greater than 2.5 wt % showed a minimal increase in the heat capacity, and any gained benefit would be overshadowed by the adverse effects to the other IL physical properites, i.e., significant increase to the viscosity, as shown in Figure 1. The addition of the nanoparticles lead to an increase in the density of 10% for the Al2O3 NEILs but a decrease of about 10% for the CB NEIL. A significant increase, about 40%, in the volumetric heat capacity was observed for the Al2O3 NEILs, but a decrease of about 30% was observed for the CB NEILs. In this case, the increase volumetric heat capacity for Al2O3 would make it a viable thermal fluid, but the CB NEILs exhibited a volumetric heat capacity lower than that for the neat IL and VP-1. The decrease in heat capacity for the CB NEIL may be due to the increased thermal conductivity of the system, because carbonaceous materials are known to have very high thermal conductivity.13 In nanocrystalline materials, a larger grain size will also correlate to a higher heat capacity.14 VP-1-containing nanoparticles could not be tested in this study because of the high Received: August 8, 2011 Revised: September 26, 2011 Published: September 26, 2011 4862

dx.doi.org/10.1021/ef2012084 | Energy Fuels 2011, 25, 4862–4864

Energy & Fuels

COMMUNICATION

Table 1. Comparison of Density, Heat Capacity, and Volumetric Heat Capacity for VP-1, [C4mmim][NTf2] and NEILs density (g/mL) temperature (°C)

heat capacity (J g

1

K 1)

volumetric heat capacity (J mL

1

K 1)

80

200

80

200

80

200

VP-1

1.02

0.87

1.73

2.18

1.76

1.90

[C4mmim][NTf2]

1.37

1.29

1.53

1.84

2.10

2.37

IL with 0.5 wt % Al2O3

1.39

1.16

1.70

1.99

2.36

2.31

IL with 1.0 wt % Al2O3

1.43

1.20

1.93

2.35

2.75

2.82

IL with 2.5 wt % Al2O3

1.51

1.32

2.02

2.40

3.05

3.17

IL with 0.5 wt % CB

1.39

1.26

1.34

1.40

1.86

1.76

IL with 1.0 wt % CB

1.39

1.23

1.14

1.35

1.58

1.66

IL with 2.5 wt % CB

1.23

1.21

1.09

1.28

1.34

1.55

2

Table 2. Static Decomposition Rates of [C4mmim][NTf2] and [C4mmim][NTf2]-Based NEILs percent mass loss per hour (wt %/h) temperature (°C)

200

225

250

275

300

325

350

375

400

[C4mmim][NTf2] [C4mmim][NTf2] with 0.5 wt % Al2O3