MULTIDIMENSIONAL GC-C-IRMS / QUADRUPOLE MS WITH A LOW-BLEED IONIC LIQUID SECONDARY COLUMN FOR THE AUTHENTICATION OF TRUFFLES AND PRODUCTS CONTAINING TRUFFLE Danilo Sciarrone, Antonino Schepis, Mariosimone Zoccali, Paola Donato, Federico Vita, Donato Creti, Amedeo Alpi, and Luigi Mondello Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.8b00386 • Publication Date (Web): 07 May 2018 Downloaded from http://pubs.acs.org on May 8, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
MULTIDIMENSIONAL GC-C-IRMS / QUADRUPOLE MS WITH A LOW-BLEED IONIC
2
LIQUID SECONDARY COLUMN FOR THE AUTHENTICATION OF TRUFFLES AND
3
PRODUCTS CONTAINING TRUFFLE
4 5
Danilo Sciarrone1, Antonino Schepis1, Mariosimone Zoccali1, Paola Donato2, Federico Vita3,
6
Donato Creti4, Amedeo Alpi5, Luigi Mondello1,6,7*
7 8
1
9
Messina, Polo Annunziata, viale Annunziata, 98168 – Messina, Italy
Dipartimento di Scienze Chimiche, Biologiche, Farmaceutiche ed Ambientali, University of
10 11
2
12
University of Messina, via Consolare Valeria, 98125 – Messina, Italy
Dipartimento di Scienze Biomediche, Odontoiatriche e delle Immagini Morfologiche e Funzionali,
13 14
3
15
– Pisa, Italy
16
4
17
Scandicci (FI), Italy
Department of Agriculture, Food and Environment, University of Pisa, Via Mariscoglio 34, 56124
Enrico Giotti S.p.A., a subsidiary of McCormick & Company, Inc., Via Pisana 592, 50018 –
18 19
5
20
University of Pisa, Via Mariscoglio 34, 56124 – Pisa, Italy
Dipartimento di Scienze Agrarie, Alimentari, Agro-ambientali, Laboratorio di Fisiologia Vegetale,
21 22
6
Chromaleont S.r.l., via Leonardo Sciascia Coop. Fede, Pal. B, 98168 – Messina, Italy
23
7
University Campus Bio-Medico of Rome, via Álvaro del Portillo 21, 00128 – Rome, Italy
24 25 26 27 28 29 30 31
*Corresponding author. Tel. +39 0906766536; fax +39 090358220.
32
E-mail address:
[email protected] (L. Mondello).
1 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
33
Abstract
34
Truffles are among the most expensive foods available in the market, usually used as flavouring
35
additives for their distinctive aroma. The most valuable species is Tuber magnatum Pico, better
36
known as “Alba white truffle”, in which bis(methylthio)methane is the key aroma compound. Given
37
the high economical value of genuine white truffles, analytical approaches are required, able to
38
discriminate between natural or synthetic truffle aroma. Gas chromatography coupled to
39
combustion-isotope ratio mass spectrometry (GC-C-IRMS), exploiting the 13C/12C ratio abundance
40
of the key flavourings compounds in foods, has been a recognized technique for authenticity and
41
traceability purposes, however a number of issues have greatly limited its widespread use, so far. In
42
the present research, a high-efficiency HS-SPME MDGC-C-IRMS with simultaneous quadrupole
43
MS detection, has been applied for the evaluation of bis(methylthio)methane, resolving the
44
coelution occurring with other components. With the aim to minimize the effect of column bleeding
45
on δ13C measurement, a medium polarity ionic liquid-based stationary phase was preferred to a
46
polyethylene glycol one, as secondary column. Twenty-four genuine white truffles harvested in
47
Italy were analysed, attaining δ13C values between -42.6‰ and -33.9‰, with a maximum standard
48
deviation lower then 0.7‰. Two commercial intact truffles and 14 commercial samples of pasta,
49
sauce, olive oil, cream, honey and fresh cheese flavoured with truffle aroma were analysed, and the
50
results from δ13C measurement were evaluated in comparison with those of genuine “white truffle”
51
range and commercial synthetic bis(methylthio)methane standard.
52 53 54 55 56 57
Keywords: Bis(methylthio)methane, Ionic liquids, Isotopic ratio, Low-bleed column, MDGC,
58
Tuber magnatum Pico, White truffle aroma.
2 Environment ACS Paragon Plus
Page 2 of 27
Page 3 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
59
1. Introduction
60
Truffles (Tuber spp.) belonging to the fungal genus Tuber are ascomycete symbiotic fungi that
61
undergo a complex life cycle in association with plant roots. Truffles, in fact, are able to form
62
fruiting bodies only in symbiosis with plant roots even if they can be rarely found under the same
63
trees. The fruiting bodies produce hundreds of volatile compounds capable of attracting insects and
64
mammals, in order to spread their ascospores [1]. Some species of truffle are among the most
65
expensive foods available in the market, usually used as flavouring additives for their distinctive
66
aroma or consumed raw added to certain dishes [2,3]. The most valuable species are Tuber
67
magnatum Pico, better known as “Alba white truffle”, Tuber melanosporum Vittad, the “Périgord
68
black truffle” and Tuber aestivum, the
69
thousands of euro per kilo. Tuber spp. fungi have been studied for a variety of reasons including
70
their beneficial activities (anti-inflammatory, anti-microbial, and anti-oxidant) and their nutritional
71
composition, but most studies have been focused on their aroma [4]. Several papers have reported
72
the chemical constituents considered to be responsible for the typical truffle aroma. Dimethylsulfide
73
has been identified in white, black and summer truffles, whereas bis(methylthio)methane is the key
74
aroma compound of white truffle. The most abundant volatiles commonly present in truffle aroma
75
include bis(methylthio)methane, dimethylsulfide, hexanal, 2-methylbutanal, and 3-methylbutanal,
76
with quantitative and qualitative variations according to the truffle species and the geographical
77
origin [5-9]. This explains why the food industry uses bis(methylthio)methane to enhance the aroma
78
of commercial food products either containing or claiming to contain truffles. Torregiani et al.
79
reported that neither the natural nor the artificial truffle oil samples adequately replicated the
80
aromas of the species of truffle examined [10]. Since bis(methylthio)methane is the main and the
81
most characteristic contributor to the aroma of white truffle, several studies have focused on its
82
variation during the storage of Tuber magnatum; the results indicated a high relative percentage of
83
bis(methylthio)methane in fresh truffles, diminishing with time [11].
“summer truffle”; the first one is routinely sold for
3 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
84
Bis(methylthio)methane can be easily added to commercial products, due to its solubility in oil and
85
stability. Its use as a flavouring agent is permitted by the law, as reported by the Joint FAO/WHO
86
Expert Committee on Food Additives (JECFA) [12]. However, there are major differences in the
87
market price, between the synthetic (100$/Kg) and the biotechnologic (5000$/Kg) compound.
88
Since aroma is made out of volatile organic compounds, the most used analytical techniques for its
89
determination in foods aroma have obviously consisted of headspace (HS) extraction coupled to gas
90
chromatography mass spectrometry (GC-MS) [13]. Several studies reported the use of HS solid
91
phase micro extraction (HS-SPME) as a sensitive technique for the evaluation of truffle aroma and
92
composition, also with regard to different storage conditions [3,13-15]. The headspace analysis of
93
white truffles fresh and after storage showed significant modifications of the aroma profile, with the
94
formation of several compounds including alcohols and acids, or changes in their quantity [16];
95
such variations would hamper the assessment of authenticity based on the relative abundance of the
96
key aroma compounds. As a consequence of the increasing consumers’ demand for genuine food
97
and ingredients, in the last years there was a need for analytical approaches able to determine
98
natural and synthetic food ingredients, in order to highlight fraudulent or unsafe practices. From the
99
earliest stages of its development, gas chromatography coupled to combustion-isotope ratio mass
100
spectrometry (GC-C-IRMS) has been a recognized technique for authenticity and traceability
101
purposes, in that it allows to determine the
102
compounds used in food products [17]. GC-C-IRMS may be useful for the detection of fraudulent
103
actions across a wide range of foods, beverages, and ingredients [18]. With regard to the
104
determination of the carbon isotopic ratio, during a GC-C-IRMS analysis compounds eluting from
105
the GC column are oxidized to CO2 and transferred to Faraday cups for m/z 44, 45 and 46 by using
106
a magnetic sector. Unlike what happens when using a GC hyphenated to a quadrupole mass
107
spectrometer (GC–qMS), where co-eluting compounds can still be identified and quantified in the
108
selected ion monitoring (SIM) mode, excellent chromatographic resolution is mandatory for GC-C-
109
IRMS analysis, since the isotopic ratio of the CO2 generated from coeluted peaks cannot be treated
13
C/12C ratio abundance of the key flavourings
4 Environment ACS Paragon Plus
Page 4 of 27
Page 5 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
110
in the same way. Baseline-to-baseline integration over an entire peak is in fact required for accurate
111
measurement of its isotopic composition, since column fractionation would retain in a slightly
112
different way the heavier isotopes, eluted in the first part of the peak, and the lighter ones, eluted in
113
the tail [19]. In order to separate compounds of interest from non-target compounds,
114
multidimensional gas chromatography (MDGC) in the heart-cut mode may be successfully applied
115
in different analytical fields [20], including isotope ratio measurements [21-29]. The MDGC-C-
116
IRMS approach has been used in the last decade to analyse flavor components [21,22], steroids in
117
urine [23,24], wax compounds in tobacco leaf and smoke samples [25], selected congeners in
118
polychlorobiphenyls (PCB) and polychloronaphthalene (PCN) [26], C2 to C5 hydrocarbons
119
produced during biomass burning experiments [27], benzene, toluene, ethylbenzene, and xylenes
120
(BTEX) in environmental samples [28] and monoaromatic hydrocarbons in complex groundwater
121
and gas-phase samples [29]. In the present research, MDGC-C-IRMS with simultaneous quadrupole
122
MS detection after the second dimension (2D), was exploited for the δ13C evaluation of
123
bis(methylthio)methane in different natural truffles and food-aromatized samples, after extraction
124
by HS-SPME.
125 126
2. Experimental Section
127
2.1. Sampling of fruiting bodies
128
Twenty-four samples of fruiting bodies of Tuber magnatum Pico were collected from different
129
areas of Italy during the autumn 2016. For each sample, different naturally grown carpophores were
130
harvested in their specific regional areas, and namely: 6 from Tuscany (San Miniato), 3 from
131
Molise, 1 from Calabria (Catanzaro), 1 from Basilicata, 2 from Abruzzo (Teramo), 6 from Piedmont
132
(Alba, Mombercelli), 5 from Umbria (Assisi). Detailed information on the geographical origin,
133
weight, and species of the samples are reported in Table 1, together with the name of the symbiotic
134
plant species, if known. Three standards of bis(methylthio)methane (two synthetic and one natural
135
flavouring substance) were kindly provided by MilliporeSigma/Supelco (Bellefonte, PA, USA) and
5 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
136
Axxence Aromatic GmbH (Emmerich, Germany). Indiana standard (Indiana University,
137
Bloomington, IN, USA), calibrated against an international standard [Vienna-Pee Dee Belemnite
138
(V-PDB)] with defined δ13C content, was used for multipoint calibration of the CO2 reference gas
139
δ13C value. All samples were stored at 4 °C.
140
2.2. Commercial samples
141
Fourteen commercial food products aromatized with truffles were purchased from local stores
142
(Messina, Italy), and namely: 3 olive oils, 3 sauces, 3 fresh cheeses, 1 honey, 1 cream, 1 pasta, 1
143
summer truffle and 1 white truffle (Table 2). Isotope ratios of the samples of interest were obtained
144
by the following formula:
145 δ13CV-PDB = 1000 (Rsample - Rstandard)/Rstandard
146 147 148
where R represents the abundance ratio of the heavier isotope of the element against the lighter
149
isotope (13C/12C).
150
2.3. HS-SPME conditions
151
Truffles were finely chopped and 0.3 g of each were put into a 20 mL crimped vial for SPME, and
152
the extractions were carried out in the headspace mode. A 1-cm long fused silica fiber coated with a
153
50/30 µm layer of divinylbenzene/carboxen/polydimethylsiloxane (MilliporeSigma/Supelco,
154
Bellefonte, PA, USA) was chosen to extract the volatile components from the truffles. The fiber
155
was conditioned following the manufacturer’s instructions previous to its use (270 °C for 0.5
156
hours). Samples were conditioned for 5 min at 50 °C, under agitation (clockwise rotation at 500
157
rpm), and then underwent the extraction step for 15 min at 50 °C, still under agitation as previously
158
indicated. Analytes were then desorbed into the GC injection port for 1 min. Blanks were run
159
between consecutive analyses. The same procedure was used for the analyses of the commercial
160
samples (using 1 g of sample) and standard solutions (1000 ppm). Each sample was analysed in
161
triplicate.
6 Environment ACS Paragon Plus
Page 6 of 27
Page 7 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
162
2.4. Instrumentation and operational conditions
163
The MDGC-C-IRMS/qMS prototype system consisted of two GC-2010 Plus gas chromatographs
164
(defined as GC1 and GC2), connected by means of a Deans-switch (DS) transfer device, an MS-
165
QP2010 Ultra quadrupole mass spectrometer, and an AOC-20i autosampler (Shimadzu Corporation,
166
Kyoto, Japan). The instrument was coupled to a VisION IRMS system (Elementar
167
Analysensysteme GmbH, Langenselbold, Germany) by means of a GC V furnace system
168
(Elementar Analysensysteme GmbH, Langenselbold, Germany) maintained at 850 °C (See Figure
169
S-1 in Supporting Information for more details). GC1 was equipped with a split/splitless injector
170
and a flame ionization detector (FID), while GC2 was connected to a rapid scanning qMS. The
171
MDGC transfer device, located in GC1, was connected to an advanced pressure control unit (APC),
172
which supplied the carrier gas (He). GC1: an SLB-5ms 30 m × 0.25 mm ID × 0.25 µm df
173
(MilliporeSigma/Supelco, Bellefonte, PA, USA) was used as column 1 at a constant flow rate of 1
174
mL/min; the following inlet pressure program was applied: 185 kPa for 1 min, then to 330 kPa at
175
1.81 kPa/min. Injection mode (260 °C): splitless (1 min), then a 10:1 split ratio was applied.
176
Temperature program: 40 oC (1 min) to 280 °C at 3 °C/min. FID (300 °C; H2 flow: 40.0 mL/min; air
177
flow rate: 400.0 mL/min; sampling rate: 80 msec) was connected to the DS switch via a 0.25 m ×
178
0.18 mm ID stainless steel uncoated column. GC2: an SLB-IL59 30 m × 0.25 mm ID × 0.2 µm df
179
(MilliporeSigma/Supelco, Bellefonte, PA, USA) was used as column 2 with the same temperature
180
program as for column 1. The following pressure program was applied by means of the APC: 140
181
kPa for 1 min, then to 265 kPa at 1.56 kPa/min. The effluent from the 2D column was splitted
182
through a zero dead-volume tee-union (Valco) to the GC V furnace and to the IRMS system via a
183
0.85 m × 0.25 mm ID uncoated column and to the qMS via a 1.5 m × 0.1 mm ID uncoated column.
184
The following settings were applied to the VisION system: acceleration voltage, 3789.907 V; trap
185
current, 600 µA; magnet current, 3685.990 mA. MS settings were: ion source, 200 °C; interface
186
temp., 200 °C; mass range, 40-400 m/z; scan speed, 1250 amu/sec. The MDGCsolution control
187
software package (Shimadzu, Kyoto, Japan) allowed to set the analytical conditions for both the
7 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 27
188
GC1 (FID) and GC2 (MS) together. The analysed compounds were identified by searching their
189
qMS spectra against the FFNSC 3.0 mass spectral library database (Shimadzu, Kyoto, Japan). The
190
IRMS used in the study was a bench top 5kV system with integrated monitoring gas delivery
191
system with a high performance silicon carbide tube furnace for providing combustion/pyrolisis
192
temperatures for the quantitative, fractionation-free conversion of organic compounds to pure gases
193
(CO2 and H2O). The CO2 produced by combustion of each component was transferred to the MS,
194
while the resulting water was removed through a Nafion tube. The system was designed to maintain
195
the chromatographic integrity of the separated compounds, preserving the chromatographic
196
resolution at the IRMS. An auxiliary He line (sample line He), automatically controlled through the
197
second channel of the APC, was used in the furnace to allow a proper control over the open split
198
conditions for the IRMS (see Figure S-1 in Supporting Information). Since in the micro-combustion
199
interface the open split was placed inside the furnace tube, therefore demanding that the open split
200
is in a steady state, the APC was operated in constant flow mode. An electron-impact ionization
201
(EI) gas source, a variable field, stigmatically focused electromagnet for beam separation and multi-
202
channel Faraday collectors for beam detection were used. IRMS data were collected by IonOS
203
stable isotope data processing software ver. 3.0.0.5196 (Elementar Analysensysteme GmbH,
204
Langenselbold, Germany); the apex track integration method was exploited to automatically find
205
the correct starting and finishing point of the peaks. A multipoint linear drift calibration was used
206
for the correction of the IRMS data during the runs since, as discussed by Skrzypek et al. [30], such
207
treatment is crucial to obtain the most accurate and precise results.
208 209
4. Results and discussion
210
4.1. System configuration and optimization
211
In order to evaluate the quality of commercial available food products labelled with a valuable
212
aroma, as in the case of truffle, the isotopic ratio measurement of a key component was exploited as
213
a
criterion
to
discriminate
between
genuine,
fortified,
8 Environment ACS Paragon Plus
or
synthetic
samples.
Page 9 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
214
Bis(methylthio)methane is known to be one of the main components of truffle flavor and for such a
215
reason it is commonly added as an additive in ”truffle flavoured” products. This organosulfur
216
compound is in fact a convenient, low cost characterizing aroma for food truffle preparation, able to
217
provide or to enhance the flavor of truffle where it is present in low amount or even absent. In this
218
concern, the present investigation was focused on the evaluation of the δ13C value of this key
219
compound in natural fruiting bodies collected during autumn 2016 in different regions of Italy, and
220
on commercial products bought in different local supermarkets. Twenty-four fruiting bodies were
221
collected from different geographical origins and analyzed as soon as shipped to our lab, in order to
222
prevent spoiling of the aroma profile. After extraction, if available in sufficient amount, the samples
223
were stored at 4 °C. A first step consisted in the conventional approach used for this analysis, based
224
on monodimensional GC after SPME extraction. In order to evaluate the occurrence of carbon
225
isotope fractionation during the HS-SPME extraction, different experimental conditions were tested
226
(see 2.3. HS-SPME conditions section) on a reference bis(methylthio)methane standard solution in
227
hexane, and compared with the results obtained after SPME. After proper optimization of the
228
extraction conditions, the δ13C values obtained from triplicate GC analyses of the reference sample
229
after HS-SPME were practically superimposable with those obtained on the same sample directly
230
injected into GC, with only a slight variation in precision (namely, 0.1σ for the reference standard
231
solution directly injected into GC, and 0.2σ for the reference standard solution after SPME). With
232
the aim to find the most suitable stationary phase for the complete separation of
233
bis(methylthio)methane, which is mandatory to avoid isotopic ratio errors. The two most
234
widespread phases for the analysis of the volatile fraction were investigated, namely apolar (A:
235
equivalent to poly(5% diphenyl/95% dimethylsiloxane)) and mid polar (B: polyethylenglycole), in
236
order to highlight possible criticisms in terms of coelution of the target compound with other
237
sample components. Figure 1 reports as an example, coelutions occurring on both columns for two
238
different
239
bis(methylthio)methane: on the 5% column (A) bis(methylthio)methane, with a linear retention
samples.
The
chromatograms
showed
a
certain
9 Environment ACS Paragon Plus
degree
of
coelutions
of
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
240
index (LRI) value of 893, in fact coeluted with heptan-2-one; the latter peak was assigned by its EI
241
spectrum (96% similarity) and LRI value of 898. On the wax phase (B), bis(methylthio)methane
242
peak (LRI 634) coeluted with hexan-2-ol (LRI 630); however for the latter peak identification was
243
only tentative, for two main reasons. First, LRI values on such stationary phase are not reproducible
244
as they are on the apolar column, and furthermore hexan-2-ol and its (methyl) substituted isomers
245
show very similar EI fragmentation patterns, preventing their unambiguous identification.
246
Furthermore, the amount of bis(methylthio)methane decreases proportionally with the storage
247
period, probably related to its very high volatility, therefore coelutions are more likely to occur, e.g.
248
on a wax stationary phase, with samples that are just harvested (Figure 2A); on the other hand the
249
separation from neighbour peaks would be easier when the concentration of bis(methylthio)methane
250
in sample is reduced after a certain storage period (Figure 2B). It is evident from Figures 1 and 2
251
that in monodimensional GC analysis, different issues can greatly affect the separation degree,
252
possibly leading to a partial coelution of the bis(methylthio)methane peak, for which evaluation of
253
the isotopic ratio value is likely to be undermined due to isotopic column fractionation along the
254
chromatographic band [21]. It must be emphasised that all the organic matter is combusted to CO2
255
before reaching the IRMS detector, and spectroscopic resolution of the CO2 obtained from a
256
chromatographic coelution is not feasible, unlike what is practical in MS, both during data
257
monitoring (i.e. in selected ion monitoring or multiple reaction monitoring mode) and in post-run
258
data processing (i.e. extracted ion mode). That being said, the complete resolution of a peak and its
259
conservation avoiding extra-column band broadening due to dead volumes along the IRMS path is
260
crucial for getting accurate results. Considering the increased complexity of commercial samples in
261
which truffle aroma is mixed with matrix components, an MDGC was deemed as necessary to solve
262
coelutions before the IRMS detection. The use of two-dimensional GC in heart-cut mode coupled to
263
IRMS is not a novel concept [21], however the technology exploited in this research presents a
264
serious step forward in its applicability. Recently, 2D systems based on a microfluidic chip have
265
been coupled to IRMS [23,25,28,29]. These systems have a common drawback, related to the
10 Environment ACS Paragon Plus
Page 10 of 27
Page 11 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
266
nature of the transfer system employed, such that each cut causes a slight change in the
267
backpressure of the first dimension (1D), in this way changing the relative retention times of the
268
next eluting components. On the contrary, the DS used in the present work was not affected by this
269
drawback: the main feature of such a transfer device is in fact the capability to generate the same 1D
270
backpressure in both stand-by and cut conditions, allowing the transfer of substantially unlimited
271
heart-cut fractions. Furthermore, the risk of isotopic fractionation resulting from the not quantitative
272
transfer of peaks due to retention time shifts during consecutive heart-cuts is completely avoided
273
(See Figure S-2 in Supporting Information for more details). From the IRMS side, the interface
274
(furnace) with the MDGC system has been optimized in terms of dead volumes, to accommodate
275
the demand that a high-efficiency separation, namely a two-dimensional analysis, is realized.
276
Another implementation of the system consists in the absence of the valve used to vent the solvent
277
between GC and IRMS. In fact, in a standard GC-C-IRMS configuration, a heart-cut valve provides
278
a way of removing the solvent peak from the system before it enters the micro-combustion oven;
279
this in order to prevent exhausting the copper oxide catalyst, and provide a long-living furnace
280
setup. Since in an MD system only the fractions of interest are transferred to a 2D column, and
281
hence to the C-IRMS, such a device useless, and therefore it was removed, to limit post-column
282
peak broadening. An additional advantage of the MDGC-C-IRMS coupling is related to a longer
283
duration of the copper oxide catalyst, since only a limited part of the sample is transferred to the 2D
284
column and then combustion involves a reduced amount of organic matter. The two GC columns
285
were selected in order to guarantee the highest possible purification of the band prior to the IRMS
286
analysis. In addition, special attention was paid in selecting the column to be used in 2D,
287
considering the foreseeable influence of column bleeding on the δ13C measurement. From the GC-
288
MS standpoint, it is well known that a reduced bleeding will positively affect identification,
289
resulting in a better spectral matching against a database of reference spectra; on the other hand,
290
further investigation is needed, concerning GC-C-IRMS analysis, since the influence of column
291
bleeding on δ13C measurement needs to be evaluated. As well known, the amount of stationary
11 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
292
phase released from the column depends on the column phase, and furthermore will be also affected
293
by the operating temperature. Being most of the GC applications accomplished in the temperature
294
program mode, the bleeding effect is most likely to affect the δ13C measurement of those
295
components eluted at high oven temperatures, while it may be negligible for early-eluting
296
components, with higher volatility. Two different mid-polarity stationary phases were evaluated,
297
and namely a polyethylene glycol column (PEG) and an ionic liquid-based SLB-IL59, which are
298
characterized by similar polarity but exhibit different selectivity [31-36]. At a glance, a substantial
299
advantage of the IL phase with respect to the PEG one is represented by the higher maximum
300
operational temperature (300 °C vs. 280 °C). Ragonese et al. [37] reported a comparison of the two
301
stationary phases, in terms of bleeding, revealing that at the column max temperature, the noise
302
level was over one order of magnitude higher for the PEG column (1.8 108 pA s), with respect to
303
the ionic liquid one (4.9 106 pA s). Aiming to assess the influence of the bleeding effect on the
304
accuracy and precision of the δ13C measurement, in this work some experiments were accomplished
305
on the two stationary phases, using a standard solution. Figure 3 shows a comparison of a vanillin
306
ex-lignin standard solution, previously determined by elemental analysis (EA) IRMS (-27.1‰),
307
analysed with the MDGC system in triplicate with an oven temperature ramp of 5 °C/min from 50
308
°C in both the dimensions, using a 5% column as 1D and: (A) the PEG or (B) the IL-based SLB-
309
IL59 column as 2D. As can be appreciated, the vanillin peak eluted approximately in the same zone,
310
even if the ionic liquid phase presented a slightly higher retention with respect to the PEG one (∆rt:
311
1.5 min). For the IL59i column at the elution temperature of vanillin (about 220 °C), the bleeding
312
was negligible, with an average δ13C value of -27.1‰, thus in accordance with the EA-IRMS
313
measured value and a good precision (0.2 σ). On the other hand, as predicted, a higher noise was
314
registered for the PEG phase at the elution temperature of vanillin (about 210 °C), which affected
315
the δ13C result both in terms of accuracy (-25,7‰) and precision (1.1σ). Based on these preliminary
316
investigations, the SLB-IL59 phase was selected as 2D column in the MDGC system, coupled to a
12 Environment ACS Paragon Plus
Page 12 of 27
Page 13 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
317
5% column (SLB-5ms) in 1D, useful for allowing the use of LRIs, to provide complementary
318
selectivity with the lowest bleeding interference [31-36].
319 320
4.2 Analysis of genuine white truffle
321
The results obtained from δ13C measurements (three replicates) of the 24 genuine white truffle
322
samples are reported in Table 1. The lowest value was obtained for sample 2 from Molise (-42.6‰),
323
while the less negative was obtained for sample 11 from Piedmont (-33.9‰). The data collected
324
were in accordance with those reported by Werning et al [38]. A good precision was in general
325
achieved employing the SPME fiber to extract the truffle flavour, with standard deviation (SD)
326
values always lower than 0.5‰, except for 6 samples, available in low amounts, for which higher
327
SD values were obtained.
328 329
Table 1. Genuine Tuber Magnatum white truffle samples analysed. The symbiotic plant,
330
geographical origin, and δ13C average values of three consecutive replicates together with the
331
measured standard deviation (SD) are reported. avg δ13C ‰ (n=3) SD
ID
Symbiotic plant
Origin
1
Unknown
Molise
-36.8
0.1
2
Unknown
Molise
-42.6
0.8
3
Unknown
Molise
-40.0
0.4
4
Unknown
Tuscany
-41.2
0.3
5
Populus alba
Tuscany
-37.6
0.2
6
Populus alba
Tuscany
-40.1
0.6
7
Populus alba
Tuscany
-38.5
0.2
8
Populus alba
Tuscany
-37.6
0.2
9
Populus alba
Tuscany
-41.9
0.6
10
Populus alba
Piedmont
-38.3
0.2
11
Populus alba
Piedmont
-33.9
0.1
12
Unknown
Piedmont
-35.4
0.3
13
Unknown
Piedmont
-37.7
0.1
14
Quercus Petraea
Piedmont
-37.9
0.2
15
Quercus Petraea
Piedmont
-39.0
0.2
16
Unknown
Abruzzo
-40.5
0.1
17
Unknown
Abruzzo
-42.0
0.2
18
Populus alba
Umbria
-38.7
0.1
13 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
19
Quercus cerris
Umbria
-40.7
0.3
20
Unknown
Umbria
-39.1
0.1
21
Quercus cerris
Umbria
-38.4
0.1
22 Juniperus communis
Umbria
-37.8
0.6
23
Unknown
Basilicata
-41.5
0.6
24
Unknown
Calabria
-38.5
0.7
Page 14 of 27
332 333
By evaluating these results in relation to the geographical origin of the samples, a slightly different
334
variability of the δ13C values can be evidenced within the different places, as reported in Figure 4.
335
The most numerous samples were harvested in Tuscany (6) and Piedmont (6), followed by Umbria
336
(5), Molise (3), Abruzzo (2), Basilicata (1) and Calabria (1). The samples from Molise showed the
337
wider range (around 6) with an SD (σ) of 2.9 and an average δ13C value of -39.8‰. Truffle
338
samples from Tuscany and Umbria showed similar ranges: the 6 samples from Tuscany showed a
339
range of around 4, with an average δ13C value of -39.5‰ and 1.8σ, while the 5 samples from
340
Umbria showed a range of around 3, with an average δ13C value of -38.9‰ and 1.1σ. The two
341
samples from Abruzzo showed an average value of -41.2‰ with 1.1σ, while samples from
342
Piedmont showed the less negative range, with a range of around 5, an average value of -37.0‰
343
and 2.0σ. The other 2 samples were from Basilicata (-41.5‰) and Calabria (-38.5‰), respectively.
344
It has to be underlined that such evaluation cannot be regarded as a statistical reference, since a
345
limited number of samples were available; on the other hand, given the difficulty and costs related
346
to the collection of a large number of samples for a deeper statistical evaluation, the present data
347
represent the widest study in the field of δ13C measurement of bis(methylthio)methane, together
348
with a recent published data on the same topic [38].
349 350
4.3 Analysis of commercial white truffle samples
351
Before
352
bis(methylthio)methane were analysed. Two of them were of petrochemical synthetic origin,
353
characterized by very low δ13C values (-56.4‰, 0.1σ and -77.1‰, 0.3σ). The third standard
the
analysis
of
the
commercial
white
truffle
14 Environment ACS Paragon Plus
samples,
three
standards
of
Page 15 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
354
presented the most positive value, viz. -28.5‰, 0.1σ, being a natural flavouring substance obtained
355
by physical, enzymatic or microbiological processes from material of vegetable, animal or
356
microbiological origin [39]. Subsequently, fourteen samples purchased from local stores (Messina)
357
were analysed using the same MDGC approach (Table 2).
358 359
Table 2. Description of the commercial truffle samples analysed. The average values of five
360
consecutive replicates together with the measured standard deviation (SD) are reported.
361
Abbreviation: n.d. = not detected ID
Description
Flavour
Avg δ13C ‰ (n=5)
SD
A
Olive oil 1
White truffle
-39.6
0.2
B
Olive oil 2
White truffle
-37.4
0.3
C
Olive oil 3
Black truffle, aroma
-40.3
0.1
D Fresh cheese 1
Summer truffle, aroma
-57.6
0.1
E Fresh Cheese 2
Black truffle, aroma Black and summer truffle, aroma White truffle
-66.5
0.8
-53.9
0.2
-42.1
0.3
F Fresh Cheese 3 G
Sauce 1
H
Sauce 2
I
Sauce 3
L
Cream Dehydrated truffle Honey
M N O P
Pasta Summer truffle
Summer truffle, aroma Black and summer truffle, aroma White truffle, aroma
-43.7
0.2
-63.7
0.1
-55.0
0.1
White truffle
-38.0
0.1
White truffle
-39.1
0.5
White truffle
-36.7
0.8
-
n.d.
-
362 363
Eight products, namely three olive oils (A-C), two sauces (G,H), one dehydrated truffle (M), one
364
honey (N) and one pasta (O) presented δ13C values compatible with the natural white truffle range
365
measured. Within these samples some of them, i.e. olive oil 1 (A: -39.6‰, 0.2σ) and olive oil 2 (B:
366
-37.4‰, 0.3σ), were characterized by the presence of the so called “witness” of declared white
367
truffle, arising from a small piece of genuine truffle added to attract the customer and to
368
demonstrate the originality of the product. Dehydrated truffle was declared as white truffle from
15 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
369
Alba: also in this case, the results obtained from δ13C measurement (M: -38.0‰, 0.1σ) were
370
compatible with the presence of an original white truffle, especially those within the range typical
371
of the samples from Piedmont region (-33.9‰/-39.0‰). Sauce 1 (G: -42.1‰, 0.3σ), honey (N: -
372
39.1‰, 0.5σ) and pasta (O: -36.7‰, 0.8σ) samples were declared to be flavoured with white truffle:
373
the analysis confirmed what labelled on the products. A different situation was found for olive oil 3
374
(C: -40.3‰, 0.1σ) and sauce 2 (H: -43.7‰, 0.2σ). Both samples were declared to be added with
375
black and summer truffle, respectively: however, both these species are characterized by the
376
absence of bis(methylthio)methane [9], as hereby confirmed by the analysis of the summer truffle
377
sample (P) that did not contain any bis(methylthio)methane. Addiction of an aroma was declared
378
for samples C and H and, most probably, it was a mixture of a synthetic and a biotechnological
379
molecule, combined to obtain a δ13C value compatible with the natural white truffle flavour. The
380
situation would be similar for the remaining samples, where no white truffle was declared among
381
the ingredients. In detail, δ13C values ranging from -53‰ to -57‰, were registered for fresh cheese
382
1 (D: -57.67‰, 0.1σ), fresh cheese 3 (F: -53.9‰, 0.2σ) and cream (L: -55.0‰, 0.1σ), all of them
383
declared as flavoured with aroma and summer truffle (sample D), aroma, black and summer truffles
384
(sample F), and aroma and white truffle (sample L). Regarding sample L, being the isotopic ratio
385
outside the range of natural bis(methylthio)methane, it is the authors’ opinion that, a low quality
386
(probably not fresh) white truffle was used, fortified with a synthetic flavour (consistently with a
387
reduced residue amount of bis(methylthio)methane). In this concern, in order to verify the influence
388
of the sample aging on the δ13C value, sample 15 was re-analysed after 2 months of storage. As
389
expected, the amount of bis(methylthio)methane was reduced to about 25% (n=3), but no
390
considerable variations of the δ13C value was observed (-40.5‰ vs. -40.7‰), as reported in Figure
391
5. Finally, values greatly outside the natural white truffle range were measured for fresh cheese 2
392
(E: -66.5‰, 0.8σ) and sauce 3 (I: -63.7‰, 0.1σ), clearly flavoured with a synthetic aroma having a
393
more negative δ13C value.
16 Environment ACS Paragon Plus
Page 16 of 27
Page 17 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
394 395
5. Conclusions
396
The present work demonstrates the capability of an MDGC-C-IRMS system to overcome some of
397
the historical problems of IRMS, associated with the combustion and measurement of impure
398
peaks. Extra-column band broadening has been greatly reduced thanks to the optimization of the
399
micro-combustion furnace and to the elimination of the heart-split valve, not necessary in a
400
multidimensional configuration. The high-efficiency 2D system has been applied for evaluation of
401
the key aroma compound of white truffle, namely bis(methylthio)methane, resolving the coelution
402
occurring with other components present in the different commercial products investigated.
403 404 405 406 407 408
Supporting information.
409
Figure S-1: scheme of the instrumentation is shown.
410
Figure S-2(A-B): operation of the transfer device employed for multi heart-cut.
411
Detailed description of the transfer device employed
412
Explanation of the operation in “stand-by” and “cut” position of the Deans switch.
413
17 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
414
References
415
[1] Splivallo, R.; Ottonello, S.; Mello, A.; Karlovsky, P. New Phytol. 2011, 189, 688-699.
416
[2] Pacioni, G.; Cerretani, L.; Procida, G.; Cichelli, A. Food Chem. 2014, 146, 30-35.
417
[3] Costa, R.; Fanali, C.; Pennazza, G.; Tedone, L.; Dugo, L.; Santonico, M.; Sciarrone, D.;
418
Cacciola, F.; Cucchiarini, L.; Dachà, M.; Mondello, L. LWT-Food Sci. Technol. 2015, 60, 905-913.
419
[4] Wang, S.; Marcone, M.F. Food Res. Int. 2011, 44, 2567-2581.
420
[5] Fiecchi, A.; Kienle, M.G.; Scala, A.; Cabella, P. Tetrahedron Lett. 1967, 8, 1681-1682.
421
[6] Gioacchini, A.M.; Menotta, M.; Guescini, M.; Saltarelli, R.; Ceccaroli, P.; Amicucci, A.;
422
Barbieri, E.; Giomaro, G.; Stocchi, V. Rapid Commun. Mass Spectrom. 2008, 22, 3147-3153.
423
[7] Mauriello, G.; Marino, R.; D'Auria, M.; Cerone, G.; Rana, G.L. J. Chromatogr. Sci. 2004, 42,
424
299-305.
425
[8] Pelusio, F.; Nilsson, T.; Montanarella, L.; Tilio, R.; Larsen, B.; Facchetti, S.; Madsen, J.Ø. J.
426
Agric. Food Chem. 1995, 43, 2138-2143.
427
[9] Culleré, L.; Ferreira, V.; Chevret, B.; Venturini, M.E.; Sánchez-Gimeno, A.C.; Blanco, D. Food
428
Chem. 2010, 122, 300–306.
429
[10] Torregiani, E.; Lorier, S.; Sagratini, G.; Maggi, F.; Vittori, S.; Caprioli, G. Food Anal. Methods
430
2017, 10(6), 1857-1869.
431
[11] Pennazza, G.; Fanali, C.; Santonico, M.; Dugo, L.; Cucchiarini, L.; Dachà, M.; D’Amico, A.;
432
Costa, R.; Dugo, P.; Mondello, L. Food Chem. 2013, 136, 668-674.
433
[12] Evaluations of the Joint FAO/WHO Expert Committee on Food Additives (JECFA)
434
http://apps.who.int/food-additives-contaminants-jecfa-database/chemical.aspx?chemID=2952
435
[13] Biniecka, M.; Caroli, S. TRAC-Trend. Anal. Chem. 2011, 30, 1756-1770.
436
[14] Costa, R.; Tedone, L.; De Grazia, S.; Dugo, P.; Mondello, L. Anal. Chim. Acta 2013, 770, 1-6.
437
[15] Bellesia, F.; Pinetti, A.; Bianchi, A.; Tirillini, B. Flavour Frag. J. 1996, 11, 239–243.
438
[16] Piloni, M.; Tat, L.; Tonizzo, A.; Battistutta, F. Ital. J Food Sci. 2005, 17(4), 463-468.
18 Environment ACS Paragon Plus
Page 18 of 27
Page 19 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
439
[17] Camin, F.; Bontempo, L.; Perini, M.; Piasentier, E. Compr. Rev. Food Sci. Food Saf. 2016, 15,
440
868-877.
441
[18] Muccio, Z.; Jackson, G.P. Analyst 2009, 134, 213-222.
442
[19] Ricci, M.P.; Merritt, D.A.; Freeman, K.H.; Hayes, J.M. Org. Geochem. 1994, 21, 561–571.
443
[20] Tranchida, P.Q.; Sciarrone, D.; Dugo, P.; Mondello, L. Anal. Chim. Acta 2012, 716, 66– 75.
444
[21] Juchelka, D.; Beck, T.; Hener, U.; Dettmar, F.; Mosandl, A. J. High Resolut. Chromatogr.
445
1998, 21, 145–151.
446
[22] Sewenig, S.; Bullinger, D.; Hener, U.; Mosandl, A. J. Agric. Food Chem. 2005, 53, 838–844.
447
[23] Brailsford, A.D.; Gavrilovìc, I.; Ansell, R.J.; Cowan, D.A.; Kicman, A.T. Drug Test Anal.
448
2012, 4, 962–969.
449
[24] Casilli, A.; Piper, T.; Azamor de Oliveira, F.; Costa Padilha, M.; Pereira, H.M.; Thevis, M.; de
450
Aquino Neto, F.R. Drug Test Anal. 2016, 8, 1204–1211.
451
[25] Brailsford, A.D.; Gavrilovìc, I.; Ansell, R.J.; Cowan, D.A.; Kicman, A.T. Drug Test Anal.
452
2012, 4, 962–969.
453
[26] Dumont, E.; Tienpont, B.; Higashi, N.; Mitsui, K.; Ochiai, N.; Kanda, H.; David, F.; Sandra, P.
454
J. Chromatogr. A 2013, 1317, 230–238.
455
[27] Horii, Y.; Kannan, K.; Petrick, G.; Gamo, T.; Falandysz, J.; Yamashita, N. Environ. Sci.
456
Technol. 2005, 39, 4206–4212.
457
[28] Nara, H.; Nakagawa, F.; Yoshida, N. Rapid Commun. Mass Spectrom. 2006, 20, 241–247.
458
[29] Ponsin, V.; Buscheck, E.T; Hunkeler, D. J. Chromatogr. A 2017, 1492, 117–128.
459
[30] Skrzypek, G.; Sadler, R. Rapid Commun. Mass Spectrom. 2011, 25, 1625–1630.
460
[31] Ragonese, C.; Sciarrone, D.; Grasso, E.; Dugo, P.; Mondello, L. J. Sep. Sci. 2016, 39, 537-544.
461
[32] Sciarrone, D.; Pantò, S.; Ragonese, C.; Tranchida, P.Q.; Dugo, P.; Mondello, L. Anal Chem.
462
2012, 84 (16), 7092–7098.
463
[33] Ragonese, C.; Sciarrone, D.; Tranchida, P.Q.; Dugo P.; Mondello, L. J. Chromatogr. A 2012,
464
1255, 130– 144.
19 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
465
[34] Sciarrone, D.; Pantò, S.; Tranchida, P.Q.; Dugo, P.; Mondello, L. Anal Chem. 2014, 86, 4295-
466
4301.
467
[35] Pantò, S.; Sciarrone, D.; Maimone, M.; Ragonese, C.; Giofrè, S.; Donato, P.; Farnetti, S.;
468
Mondello, L. J. Chromatogr. A 2015, 1417, 96–103.
469
[36] Sciarrone, D.; Pantò, S.; Donato, P.; Mondello, L. J. Chromatogr. A 2016, 1475, 80-85.
470
[37] Ragonese, C.; Sciarrone, D.; Tranchida, P.Q.; Dugo, P.; Dugo, G.; Mondello, L. Anal. Chem.
471
2011, 83, 7947-7954.
472
[38] Wernig, F.; Buegger, F.; Pritsch, K.; Splivallo, R. Food Control 2018, 87, 9-16.
473
[39] Regulation (EC) no 1334/2008 of the european parliament and of the council of 16 December
474
2008 on flavourings and certain food ingredients with flavouring properties for use in and on foods
475
and amending Council Regulation (EEC) No 1601/91, Regulations (EC) No 2232/96 and (EC) No
476
110/2008 and Directive 2000/13/EC.
20 Environment ACS Paragon Plus
Page 20 of 27
Page 21 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
477
Figure legends
478
Figure 1. Coelutions of bis(methylthio)methane after monodimensional GC analysis on apolar (A)
479
and mid polar (B) stationary phase.
480
Figure 2. Comparison of the bis(methylthio)methane peak obtained on a wax column after analysis
481
of a white truffle sample: just harvested (A) and after two months storage (B).
482
Figure 3. Analysis of standard vanillin ex-lignin for bleeding evaluation on the polyethylene glycol
483
(A) and ionic liquid-based SLB-IL59 (B) stationary phase.
484
Figure 4. δ13C ranges on the basis of the geographical origin for the genuine white truffle samples.
485
Figure 5. D2 IRMS chromatograms of bis(methylthio)methane in: just harvested A) and two-month
486
aged truffle sample B).
487
21 Environment ACS Paragon Plus
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
488 489
For TOC only
490
22 Environment ACS Paragon Plus
Page 22 of 27
Page 23 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
Figure 1. Coelutions of bis(methylthio)methane after monodimensional GC analysis on apolar (A) and mid polar (B) stationary phase. 83x85mm (300 x 300 DPI)
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Figure 2. Comparison of the bis(methylthio)methane peak obtained on a wax column after analysis of a white truffle sample: just harvested (A) and after two months storage (B). 83x48mm (300 x 300 DPI)
ACS Paragon Plus Environment
Page 24 of 27
Page 25 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
Figure 3. Analysis of standard vanillin ex-lignin for bleeding evaluation on the polyethylene glycol (A) and ionic liquid-based SLB-IL59i (B). 83x116mm (300 x 300 DPI)
ACS Paragon Plus Environment
Analytical Chemistry 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Figure 4. δ13C ranges on the basis of the geographical origin for the genuine white truffle samples. 83x86mm (300 x 300 DPI)
ACS Paragon Plus Environment
Page 26 of 27
Page 27 of 27 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
Figure 5. D2 IRMS chromatograms of bis(methylthio)methane in: just harvested A) and two- month aged truffle sample B). 83x38mm (300 x 300 DPI)
ACS Paragon Plus Environment