Rapid, Sensitive, and Carryover Contamination ... - ACS Publications

Aug 31, 2017 - College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, Zhejiang 310058, People's Republic of China. ‡...
1 downloads 0 Views 2MB Size
Subscriber access provided by Stockholm University Library

Article

A rapid, sensitive and carryover contamination-free loop-mediated isothermal amplification-coupled visual detection method for ‘Candidatus Liberibacter asiaticus’ Wenjuan Qian, Youqing Meng, Ying Lu, Cui Wu, Rui Wang, Liu Wang, Cheng Qian, Zunzhong Ye, Jian Wu, and Yibin Ying J. Agric. Food Chem., Just Accepted Manuscript • DOI: 10.1021/acs.jafc.7b03490 • Publication Date (Web): 31 Aug 2017 Downloaded from http://pubs.acs.org on September 1, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Journal of Agricultural and Food Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 29

Journal of Agricultural and Food Chemistry

1

A rapid, sensitive and carryover contamination-free loop-mediated isothermal

2

amplification-coupled visual detection method for ‘Candidatus Liberibacter

3

asiaticus’

4

Wenjuan Qian ab, Youqing Meng c, Ying Lu c, Cui Wu ab, Rui Wang ab, Liu Wang ab,

5

Cheng Qian ab, Zunzhong Ye ab *, Jian Wu ab and Yibin Ying ad

6

a

7

Hangzhou 310058, China.

8

b

9

Ministry of Agriculture, Hangzhou 310058, China.

College of Biosystems Engineering and Food Science, Zhejiang University,

Key Laboratory of On Site Processing Equipment for Agricultural Products,

10

c

Zhejiang Plant Protection and Quarantine Bureau, Hangzhou 310020, China.

11

d

Zhejiang A&F University, Hangzhou, Zhejiang 311300, China.

12

Correspondence

13

(Z. Ye) E-mail: [email protected]. Tel: 0086-571-88982282

14

Fax: 0086-571-88982282 College of Biosystems Engineering and Food Science,

15

Zhejiang University, Hangzhou 310058, China.

1

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

16

ABSTRACT:

17

Huanglongbing is a devastating citrus disease and ‘Candidatus Liberibacter

18

asiaticus’ is the most prevalent Huanglongbing-associated bacterium. Its field

19

detection remains challenging. In this work, a visual, rapid, sensitive and carryover

20

contamination-free method was developed for field detection of Las. Leaf samples

21

were treated with 500 µL 0.5 M sodium hydroxide solution for 3 min and 50-fold

22

dilutions were directly amplified by loop-mediated isothermal amplification. Then, a

23

novel SYTO 9 based visual detection method was used to evaluate amplification

24

results without uncapping operation. Negative samples remained colorless while

25

positive samples generated obvious green fluorescence which could be easily

26

distinguished by naked eyes with a mini fluorescent-emission cartridge developed

27

originally. The proposed detection method could be accomplished within 40 min and

28

is about 100 times more sensitive than conventional TaqMan PCR. The reliability of

29

this method was also verified by analyzing practical samples.

30

Keywords: Huanglongbing, Candidatus Liberibacter asiaticus, field detection, crude

31

DNA extraction, isothermal amplification, visual detection

2

ACS Paragon Plus Environment

Page 2 of 29

Page 3 of 29

Journal of Agricultural and Food Chemistry

32

Introduction

33

Citrus huanglongbing (HLB), also known as citrus greening disease, is one of the

34

most destructive diseases of citrus worldwide.1 Three fastidious gram negative

35

bacteria have been associated with citrus HLB: ‘Candidatus Liberibacter asiaticus’

36

(Las), ‘Candidatus Liberibacter americanus’ (Lam) and ‘Candidatus Liberibacter

37

africanus’ (Laf). Among them, Las is the most prevalent HLB-associated bacterium in

38

Asia as well as in the western countries.2 Infected citrus can present a long latency

39

period and will be destroyed or become unproductive in 5 to 8 years following

40

infection.3, 4 However, there is no effective cure of the disease, and hence infected

41

trees have to be removed immediately at early stage of the infection to prevent the

42

spread of the disease.5 Thus, accurate and convenient detection methods play an

43

important role in reducing the incidence of HLB. Some detection methods such as

44

serologic assays, electron microscopy and biological assays have been developed, but

45

the detection results are inconsistent due to the low concentration and uneven

46

distribution of pathogens in infected citrus.6-11 Moreover, many of these methods have

47

drawbacks of being time-consuming and requiring complex facilities which limit their

48

application in field and places where complex facilities may not be available. Hence,

49

it is urgent to develop a rapid, affordable, simple and reliable method for field

50

detection of Las in a timely fashion.

51

Currently, polymerase chain reaction (PCR) is widely used to detect Las in

52

infected plants because of its high sensitivity and reproducibility.12-17 However, it is

53

not applicable for field detection due to its reliance on non-portable thermal cycler 3

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

Page 4 of 29

54

and other basic apparatus for molecular biological experiments. The emergence of

55

isothermal amplification like loop-mediated isothermal amplification (LAMP) has

56

overcome constraints mentioned above since they can be conducted at a constant

57

temperature.

58

LAMP assay was first described by Notomi et al as a simple, rapid, sensitive and

59

cost-effective technique for detection of specific DNA.18 It is conducted with 4~6

60

primers recognizing 6~8 regions of the target DNA which confers extremely high

61

specificity.

62

between 60 to 65 °C in a simple and inexpensive device like a water bath or a heating

63

block.

18,19

64

has

already

65

tufB-secE-nusG-rplKAJL-rpoB gene cluster.20,

66

abandoned thermal cyclers, tedious gel electrophoresis analysis or optical instrument

67

based fluorescent detection is unavoidable which greatly limits its field application.

68

Visual detection of LAMP products is a promising approach for field detection since it

69

is rapid, direct and simple. Aravind Ravindran et al have been reported to detect Las

70

visually via direct observation of turbidity in LAMP reaction tubes22 but the turbidity

71

produced by LAMP is difficult to identify by naked eyes when the amount of

72

amplicons is insufficient23. They also enhanced visual detection of Las by adding

73

manganese-quenched calcein to generate fluorescence upon amplification. However,

74

the fluorescence difference between positive and sensitive samples was difficult to

75

distinguish under normal light and an additional UV light was needed. Also,

18,19

In contrast to PCR, LAMP can be carried out at a single temperature

LAMP assay for the detection of Las in infected plants or vector insects been

reported

based

on

conserved 21

sequence

of

the

Although this method has

4

ACS Paragon Plus Environment

Page 5 of 29

Journal of Agricultural and Food Chemistry

76

manganese-quenched calcein detection is reported to suffer from inhibition by

77

manganese to some extent.

78

visual detection of LAMP products by employing intercalating dyes such as SYBR

79

Green or SYTO dyes26-28 to observe a color change but the requirement of uncapping

80

operation presents a high risk of carryover contamination.29, 30 Xuhui Wu et al have

81

developed a SYBR Green I based LAMP visual detection method of Las without

82

uncapping operation by adding SYBR Green I to the inside of the lid prior to

83

amplification.31 However, an additional centrifugation operation is needed to mix the

84

pre-added SYBR Green I to the reaction solution. What’s more, the color change

85

resulting from intercalating dyes may be subtle for some users because of the high

86

background signal and the adjacent colorimetric change.32-34 In addition, Rigano et al

87

have developed a visual LAMP method combined with a lateral flow dipstick assay to

88

detect a hypothetical protein region from Las.35 This method still presents a high risk

89

of carryover contamination due to the uncapping operation.

24, 25

Some researchers have attempted to accomplish

90

Another obstacle for field detection of HLB is DNA extraction. Standard

91

extraction methods and commercial kits are not appropriate for rapid filed detection

92

due to the cumbersome steps and long operation duration.36 Fortunately, LAMP shows

93

high tolerance to interferences from biological contaminants37 and, hence, simplified

94

sample preparation. So far, some DNA crude extraction methods have already been

95

reported for LAMP detection of Las. 2, 35 A centrifuge is still necessary in these boiling

96

methods.

97

More convenient and simpler sample preparation methods are still needed.

In this content, we have developed a novel LAMP-coupled visual detection 5

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

98

method which can overcome the weaknesses of methods mentioned above for rapid

99

field detection of HLB associated with Las. The whole detection process (from leaf

100

sampling up to result) of this SYTO 9 based method could be completed in 40

101

minutes. This method is characterized by the novelties and advantages as following: (i)

102

A very short (∼3 min) DNA extraction step was performed on leaf samples by simple

103

treatment with sodium hydroxide (NaOH) solution without heating treatment or

104

centrifugation; (ii) The novel visual detection method of LAMP products just needed

105

low concentration fluorescent dye and SYTO 9 was added before amplification,

106

preventing the risk of carryover contamination; (iii) Instead of former adjacent

107

colorimetric change, positive samples emitted green fluorescent which could be easily

108

distinguished from colorless negative samples; (iv) No longer needing thermal cycler

109

and other expensive or non-portable apparatuses, a portable heater and a mini

110

fluorescent-emission cartridge (460 nm) invented by our Lab are enough for visual

111

assay of LAMP.

112

Materials and methods

113

Plant material

114

Asymptomatic and symptomatic disease leaf samples of infected citrus trees and

115

352 blind citrus leaf samples obtained from 9 different regions in Zhejiang Province

116

were collected by Zhejiang Plant protection and quarantine Bureau. Healthy citrus

117

leaves as negative controls were bought from local supermarket.

118

NaOH-based DNA crude extraction

119

A piece of midrib tissues (around 0.6×2 cm, 50 mg) of a leaf sample was cut up 6

ACS Paragon Plus Environment

Page 6 of 29

Page 7 of 29

Journal of Agricultural and Food Chemistry

120

and immerged in 500 µL 0.5 M NaOH in a mortar. After grinding for 1 min and

121

standing for 9 min at room temperature, the supernatant of slurries was serially diluted

122

(1:1, 1:5, 1:50, and 1:500) with Tris-EDTA (TE) buffer. 2.5 µL of the rude cell lysate

123

was directly used as template for LAMP assay. The durations of lysis were studied by

124

crushing the leaves in 0.5 M NaOH for 1 min and then letting the slurry stand for 0, 2,

125

5 and 9 min, respectively. For a comparative test, standard DNA extraction was

126

conducted using Plant Genomic DNA Kit (Tiangen Biotech Co., Ltd, Beijing, China).

127

Primer designed for LAMP

128

A DNA fragment of Las encompassing a bacteriophage-type DNA polymerase 2, 38

129

region (GenBank NO. M94302) was selected as target sequence.

A set of six

130

LAMP primers including a pair of inner primer (FIP and BIP), two out primers (F3

131

and B3) and two loop primers (LF and LB) were designed using Primer Explorer ver.

132

4 (http://primerexplorer.jp/ elamp4.0.0/index.html). The specificity of primers was

133

insured by Blast analysis and sequences are displayed in Figure 1.

134

LAMP Assay

135

LAMP was performed in a total of 25 µL reaction mixture containing 1.6 µM of

136

FIP and BIP, 0.2 µM of F3 and B3, 0.4 µM of LF and LB, 16 U of Bst DNA

137

polymerase large fragment (New England Biolabs Inc., Ipswich, MA), 1.4 mM of

138

dNTPs, 2.5 µL of 10 × Thermopol Reaction buffer (New England Biolabs Inc.,

139

Ipswich, MA), 6.0 mM of MgSO4, 0.8 M of Betaine, 4µM of SYTO 9 (Thermo

140

Fisher Scientific Inc., Waltham, MA USA) and 2.5 µL of target DNA. DNA extracted

141

from healthy citrus leaves was used as negative controls. For LAMP-coupled visual 7

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

142

detection, the mixture in each tube was incubated at 65 °C for 35 min on a

143

conventional heating block (Sangon Biotech Co., Ltd., Shanghai, China) after

144

layering with 10 µL of mineral oil to avoid evaporation. For real-time LAMP, the

145

QuantStudioTM3 Real Time PCR System (Thermo Fisher Scientific Inc., Waltham,

146

MA USA) was used to collect fluorescence signal every 60 s. Time threshold (Tt)

147

value means the time that fluorescence reached the threshold.

148

Real-time TaqMan PCR.

149

Primer-probe sets, HLBaspr, HLBafpr and HLBampr, employed for real-time

150

TaqMan PCR were reported in previous paper by Li W. et al10 and synthesized by

151

Sangon Biotech (Shanghai, China). The 25 µL total reaction volumed 12.5 µL

152

FastStart Essential Probes Master reaction mix (Roche Diagnostics Ltd., Switzerland),

153

250 nM of each primer, 150 nM of target probe, 2.5 µL template and 8.7 µL Sterile

154

water. The standard amplification protocol was 98 °C for 20 s followed by 45 cycles

155

at 95 °C for 20 s and 58 °C for 40 s. Fluorescence was collected on the

156

QuantStudioTM3 Real Time PCR System at the end of each cycle. Time consumed

157

was defined as cycle number while Cycle threshold (Ct) value means the cycle

158

number that fluorescence reached the threshold.

159

Sensitivity of Real-time TaqMan PCR and LAMP

160

To compare the sensitivity of real-time TaqMan PCR and LAMP, amplification

161

was performed on a dilution series of DNA extracted from symptomatic leaves by

162

Plant Genomic DNA Kit (Tiangen Biotech Co., Ltd, Beijing, China). DNA template

163

was adjusted to the initial concentration of 100 ng/µL and diluted in 1:10 serials. 8

ACS Paragon Plus Environment

Page 8 of 29

Page 9 of 29

Journal of Agricultural and Food Chemistry

164

Before DNA amplification, the diluents were mixed with host DNA extracted from

165

Las-free citrus leaves to ensure that the total DNA concentration was 100 ng/µL to

166

eliminate the effect of host DNA. For each reaction, 2.5 µL DNA templates were

167

added for real-time TaqMan PCR and LAMP.

168

Specificity of Las-LAMP

169

In order to evaluate the specificity of Las-LAMP assay, several other main citrus

170

diseases infected by bacterial or fungal plant pathogens, including citrus canker, citrus

171

anthracnose, citrus scab, citrus black spot and citrus brown spot were tested by

172

Las-LAMP primer. DNA from Las-free citrus samples was used as negative control.

173

Visual detection of LAMP products

174

4 µM of SYTO 9 was added into the reaction mixture before amplification. Then,

175

with the help of mini fluorescent-emission cartridge (460 nm) developed by our lab,

176

positive amplifications would emit green fluorescence (520 nm) while negative

177

amplifications generated no fluorescence. To figure out the main reason for high

178

background signal of negative samples, we detected the fluorescence of reaction

179

mixtures at room temperature before LAMP amplification. Furthermore, to ensure the

180

detection specificity and eliminate false-positive results, reaction tubes were

181

fore-heated under 45 °C, 65 °C, 75 °C and 85 °C respectively for 2 min before visual

182

detection.

183

Detection of practical samples

184

For LAMP assay, DNA was extracted from a piece of midrib tissues (around

185

0.6×2 cm, 50 mg) of a citrus leaf with 500 µL 0.5 M NaOH for 3 min (including 1 9

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

186

min of grinding and 2 min standing). Thereafter, the solution was 50-fold diluted in

187

TE buffer and then amplified by LAMP at 65 °C on a heating block for 35 min. After

188

the amplification, the mixture was immediately visual judged via the mini

189

fluorescent-emission cartridge (Scheme 1).

190

To evaluate the feasibility of visual detection of Las, a total of 60 samples with 30

191

asymptomatic and 30 symptomatic plant materials from different infected trees were

192

divided into 10 groups randomly and tested by LAMP-coupled visual detection

193

method. Real-time TaqMan PCR and real-time LAMP were used as control.

194

Finally, 352 blind field samples collected from 9 different regions in Zhejiang

195

Province were tested to evaluate the HLB infection condition of Zhejiang Province.

196

Results and discussions

197

NaOH-based DNA crude extraction

198

In order to simplify operation processes and reduce sampling time, DNA was

199

extracted without purification. Different lysis time and dilution ratios were compared

200

to evaluate the proposed NaOH-based DNA extraction method. As shown in Table 1,

201

no positive signal was obtained when the crude cell lysates were directly used without

202

dilution no matter how long the lysis time was. This phenomenon could be related to

203

the presence of LAMP inhibitors which were introduced during the lysis process and

204

compromised the analysis results such as carryover NaOH or the compound arising

205

from the cytolysis. However, with appropriate dilution, the effect of inhibitor could be

206

eliminated to some extent. According to the Tt values in Table 1, 5-fold dilution still

207

showed negative impact on LAMP amplification while the result of 500-fold dilution 10

ACS Paragon Plus Environment

Page 10 of 29

Page 11 of 29

Journal of Agricultural and Food Chemistry

208

was inferior to that of 50-fold dilution due to the low DNA concentration. Therefore,

209

we chose 50-fold dilution in our further study.

210

To shorten the whole detection time, different durations of lysis were also studied.

211

Table 1 illustrated that there was no significant difference among 3 min, 6 min and 10

212

min incubation. And the amplification ability of the crude extracted DNA had no

213

significant difference with that of standard DNA extraction by commercial kit. For

214

field detection, a method which requires less time is more efficient and convenient.

215

Therefore, 3 min was applied for lysis.

216

In conclusion, DNA crude extraction was performed with 500 µL 0.5 M NaOH

217

for 3 min (including 1 min of grinding and 2 min standing) and 50-fold dilutions were

218

applied for LAMP amplification and visual detection in the following assay.

219

Sensitivity and Specificity of LAMP

220

To compare the sensitivity of Las-LAMP and real-time TaqMan PCR, serial

221

dilutions of purified DNA ranging from 1.0 ×102 ng/µL to 1.0×10-5 ng/µL extracted

222

from a Las positive plant were used. As shown in Figure 2, the limit-of-detection

223

(LOD) of real-time TaqMan PCR was 1.0 ×10-2 ng/µL while it was 1.0 ×10-4 ng/µL

224

for real-time LAMP, suggesting that LAMP was potentially about 100 times more

225

sensitive than real-time TaqMan PCR. LAMP products were also visually detected by

226

mini fluorescent-emission cartridge and the results were consistent to real-time LAMP

227

that products of the first 7 dilutions emitted an obvious green fluorescence while the

228

others showed no fluorescence (Figure 2). The intensity of fluorescence emitted by

229

products amplified from different concentration of initial target templates showed no 11

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

230

significant difference and all could be easily distinguished from negative samples by

231

naked eyes. This may be due to the substantial and almost the same amount of LAMP

232

products according to the plateau of their amplification curves of real-time LAMP.

233

The specificity of LAMP primers was tested on several other main citrus diseases

234

infected by bacterial or fungal plant pathogens, including citrus canker, citrus

235

anthracnose, citrus scab, citrus black spot and citrus brown spot. No positive result

236

was observed except the Las-infected sample, indicating a high level of detection

237

specificity of LAMP assay. (ESI, Table S1).

238

Visual detection of LAMP products

239

SYTO 9 fluorescent dye has already been reported to be used for visual detection

240

of LAMP products.28 However, the detection results may be subtle for some users

241

because of the adjacent colorimetric change (from orange to green). Since high

242

concentration fluorescent dye has a negative impact on LAMP amplification, SYTO 9

243

is added after amplification by uncapping operation which will cause carryover

244

contamination. In this paper, we developed a novel SYTO 9 based visual detection

245

method of LAMP products which just needed low concentration fluorescent dye. By

246

adding SYTO 9 fluorescent dye before amplification and giving an exciting light to

247

amplification products, the color of positive samples changed from colorless to green,

248

which could easily distinguished by naked eyes with the mini fluorescent-emission

249

cartridge (460 nm) developed by our Lab.

250

Before LAMP amplification, SYTO 9 with a concentration of 4 µM was added

251

into the reaction mixture, which would intercalate into gradually accumulated 12

ACS Paragon Plus Environment

Page 12 of 29

Page 13 of 29

Journal of Agricultural and Food Chemistry

252

double-stranded DNA (ds DNA) as the reaction progress and generate fluorescence

253

simultaneously. Combined with the mini fluorescent-emission cartridge, we hoped

254

that the positive amplifications could be visually distinguished from the negative ones

255

but it failed at room temperature because both positive and negative samples

256

generated green fluorescence easily observed by naked eyes (Figure 3c).

257

Traditionally, the fluorescent signal of SYTO 9 for real-time DNA amplification

258

was collected at high temperature like 72 °C of extending in PCR and the background

259

signal was weak enough to be ignored. However, negative samples displayed high

260

background signal at low temperature which was demonstrated by melt curve plot in

261

Figure 3b. Since the fluorescent amplification curve of the negative samples in

262

real-time LAMP remained flat during the whole amplification process (Figure 3a),

263

we think that such high background signal had nothing to do with the non-specific

264

amplification. To figure out what is the main reason for the high background signal of

265

negative samples, we detected the fluorescence of reaction mixtures before LAMP

266

amplification. As shown in Figure 3d, the positive sample, negative sample and even

267

blank control which used water as template could emit obvious fluorescence without

268

amplification while no fluorescence was observed when there were no primers in

269

reaction mixtures which indicated that the high background signal was highly related

270

to the primers in reaction mixtures. Since SYTO 9 is a ds DNA-specific dye, its

271

fluorescent signal should be low enough in the solution of primers. However, in

272

LAMP system, the concentration of primers, especially the two inner primers which

273

are usually over 40 nt length, is relatively high. These long primers tend to be 13

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

274

presented as secondary structures at room temperature. Therefore, high fluorescence

275

intensity was produced by these primers. Once the temperature was raised up, the

276

secondary structures of these primers were dissociated, and the fluorescent signal of

277

the negative samples also decreased. Furthermore, the melting temperature of these

278

primer secondary structures is far below that of the LAMP products (Figure 3b). So

279

an appropriate high temperature can subtract the background signal caused by these

280

secondary structures. Therefore,fluorescence observations of LAMP products must

281

be performed at elevated temperature for maximum discrimination between positive

282

and negative amplifications.

283

As seen in Figure 3e, the fluorescence from positive amplifications was obvious

284

and could be observed by naked eyes at all temperatures except 85 °C at which the

285

two strands of the desired products were dissociated so that the fluorescent signal was

286

also decreased. Both 65 °C and 75 °C were appropriate for visual detection because

287

background signal was totally eliminated while the fluorescent intensity of positive

288

products was still sufficiently strong. After comprehensive consideration, we chose

289

65 °C for visual detection since it is also the temperature for LAMP amplification and

290

will be more convenient to perform.

291

This LAMP-coupled visual detection method can easily discriminate between

292

positive and negative reactions without requiring cumbersome manipulations and

293

elaborate instrumentation. The risk of carryover contamination is also eliminated.

294

Detection of practical samples

295

For the citrus industry, the detection capability for asymptomatic samples of Las 14

ACS Paragon Plus Environment

Page 14 of 29

Page 15 of 29

Journal of Agricultural and Food Chemistry

296

associated with the devastating disease HLB is vital. The feasibility for

297

LAMP-coupled visual detection method described here was validated by 60 samples

298

containing 30 asymptomatic and 30 symptomatic plant materials obtained from

299

different infected trees. The 60 samples were divided into 10 groups and the detection

300

result of one group is shown in Figure 4 (Detection results of other groups were

301

shown in ESI). All samples were tested positive by LAMP-coupled visual detection

302

method and real-time LAMP while 8 asymptomatic samples were missed by real-time

303

PCR for the lower sensitivity compared to LAMP-coupled visual detection method

304

and real-time LAMP. These results indicate that this LAMP-coupled visual detection

305

method can be deployable for the detection of Las in asymptomatic leaf samples and

306

it is feasible even using crude extracts, needing no expensive equipment and with less

307

time-consumption making this method very attractive to growers.

308

Subsequently, to investigate the distribution and severity of HLB in Zhejiang

309

Province, a systematic survey of HLB was conducted in the citrus-growing areas. A

310

total of 352 field samples from 9 different regions were collected and tested by

311

proposed LAMP-coupled visual detection method. Real-time TaqMan PCR and

312

real-time LAMP were used as control. As shown in Figure 5, among 352

313

field-collected samples, 36 samples were tested positive by LAMP-coupled visual

314

detection method and real-time LAMP while only 21 tested positive by real-time

315

TaqMan PCR. It is noted that all samples that were found to be positive by real-time

316

PCR were also positive by real-time LAMP and LAMP-coupled visual detection

317

method. The detection rate of 352 field samples of LAMP-coupled visual detection 15

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

318

method and real-time LAMP were both 10.23% (36/352) while only 5.97% (21/352)

319

of real-time TaqMan PCR. Therefore, the proposed LAMP-coupled visual detection

320

method showed great reliability for detection of Las compared to conventional

321

real-time TaqMan PCR and can be an alternative detection method used for field

322

detection of Las.

323

In summary, we have developed an extremely rapid, sensitive and carryover

324

contamination-free LAMP-coupled visual detection method for filed detection of Las

325

from citrus leaf samples. Cumbersome DNA purification steps in this method are

326

omitted and DNA extraction can be accomplished in only 3 min with NaOH solution,

327

making detection in field more efficient and convenient. Unlike existing SYTO 9

328

based visual detection methods, this innovative visual method can be performed

329

without exposing amplicons to the environment, reducing the risk of carryover

330

contamination. Instead of former adjacent colorimetric change, the color of positive

331

samples changes from colorless to green and can be easily observed by naked eyes.

332

No longer requiring the expensive thermal cycler, a portable heater and a mini

333

fluorescent-emission cartridge invented by our Lab are employed for visually assay of

334

LAMP. Compared to conventional real-time PCR, this LAMP-coupled visual

335

detection method of Las is more sensitive and rapid. The whole detection process can

336

be accomplished within 40 min from leaf sampling to result. The feasibly of this

337

method has been verified by analysis of practical field samples. Overall, the

338

affordable, sensitive, rapid and convenient method would contribute a lot to the citrus

339

planting industry by field detection of Las. 16

ACS Paragon Plus Environment

Page 16 of 29

Page 17 of 29

Journal of Agricultural and Food Chemistry

340

341

Abbreviations Used HLB

Citrus huanglongbing

Las

Candidatus Liberibacter asiaticus

PCR

Polymerase chain reaction

LAMP

Loop-mediated isothermal amplification

NaOH

Sodium hydroxide

Tt

Time threshold

Ct

Cycle threshold

RSD

Relative standard deviation

SD

Standard deviation

TE

Tris-EDTA

LOD

Limit-of-detection

Acknowledgement

342

This work was supported by National Natural Science Foundation of China

343

(31571918) and Hong Kong, Macao and Taiwan Scientific and Technological

344

Cooperation Projects (2015DFT30150).

345

Supporting Information

346 347

Brief statement in nonsentence format listing the contents of the material supplied as Supporting Information.

348 349

References 17

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393

(1) Freitas, D. d. S.; Carlos, E. F.; Gil, M. r. C. S. d. S.; Vieira, L. G. E.; Alcantara, G. B., NMR-Based Metabolomic analysis of Huanglongbing-asymptomatic and-symptomatic citrus trees. J. Agric. Food Chem. 2015, 63, 7582-7588. (2) Keremane, M. L.; Ramadugu, C.; Rod.riguez, E.; Kubota, R.; Shibata, S.; Hall, D. G.; Roose, M. L.; Jenkins, D.; Lee, R. F., A rapid field detection system for citrus huanglongbing associated ‘Candidatus Liberibacter asiaticus’ from the psyllid vector, Diaphorina citri Kuwayama and its implications in disease management. Crop Prot. 2015, 68, 41-48. (3) Chiyaka, C.; Singer, B. H.; Halbert, S. E.; Morris, J. G.; van Bruggen, A. H., Modeling huanglongbing transmission within a citrus tree. P. Natl. Acad. Sci.USA.2012, 109, 12213-12218. (4) Gottwald, T.; Aubert, B.; Zhao, X.-Y., Preliminary analysis of Citrus greening(huanglungbin) epidemics in the People's Republic of China and French Reunion Island. Phytopathology 1989, 79, 687-693. (5) Wang, N.; Trivedi, P., Citrus huanglongbing: a newly relevant disease presents unprecedented challenges. Phytopathology 2013, 103, 652-665. (6) McClean, A., Greening disease of sweet orange: its transmission in propagative parts and distribution in partially diseased trees. Phytophylactica 1970, 2, 263-268. (7) Garnier, M.; Martin-Gros, G.; Bové, J. M. In Monoclonal antibodies against the bacterial-like organism associated with citrus greening disease. Ann. Inst. Pasteur/Microbiol. 1987, 138, 639-650. (8) Gottwald, T. R., Current epidemiological understanding of citrus huanglongbing. Annu. Rev. Phytopathol. 2010, 48, 119-139. (9) McClean, A., Greening disease of sweet orange: its transmission in propagative parts and distribution in partially diseased trees. Phytophylactica 1970, 2, 263-268. (10) Li, W.; Hartung, J. S.; Levy, L., Quantitative real-time PCR for detection and identification of Candidatus Liberibacter species associated with citrus huanglongbing. J. Microbiol. Meth. 2006, 66, 104-115. (11) Su, H.; Chang, S., Electron microscopical study on the heat and tetracycline response, and ultra-structure of the pathogen complex causing citrus likubin disease. Proc. 8th Int. Congr. Electron Microscopy 1974, 2, 628-629. (12) Fujikawa, T.; Miyata, S.-I.; Iwanami, T., Convenient detection of the citrus greening (huanglongbing) bacterium ‘Candidatus Liberibacter asiaticus’ by direct PCR from the midrib extract. PloS one 2013, 8, e57011. (13) Li, W.; Levy, L.; Hartung, J. S., Quantitative distribution of ‘Candidatus Liberibacter asiaticus’ in citrus plants with citrus huanglongbing. Phytopathology 2009, 99, 139-144. (14) Wang, Z.; Yin, Y.; Hu, H.; Yuan, Q.; Peng, G.; Xia, Y., Development and application of molecular ‐based diagnosis for ‘Candidatus Liberibacter asiaticus’, the causal pathogen of citrus huanglongbing. Plant Pathol. 2006, 55, 630-638. (15) Ananthakrishnan, G.; Choudhary, N.; Roy, A.; Sengoda, V.; Postnikova, E.; Hartung, J.; Stone, A.; Damsteegt, V.; Schneider, W.; Munyaneza, J., Development of primers and probes for genus and species specific detection of ‘Candidatus Liberibacter species’ by real-time PCR. Plant Dis. 2013, 97, 1235-1243 (16) Jagoueix, S.; Bové, J. M.; Garnier, M., PCR detection of the two «Candidatus» liberobacter species associated with greening disease of citrus. Mol.Cell.Probe. 1996, 10, 43-50. (17) Coy, M.; Hoffmann, M.; Gibbard, H. K.; Kuhns, E.; Pelz-Stelinski, K.; Stelinski, L., Nested-quantitative PCR approach with improved sensitivity for the detection of low titer levels of 18

ACS Paragon Plus Environment

Page 18 of 29

Page 19 of 29

Journal of Agricultural and Food Chemistry

394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437

Candidatus Liberibacter asiaticus in the Asian citrus psyllid, Diaphorina citri Kuwayama. J. microbiol. Meth. 2014, 102, 15-22. (18) Notomi, T.; Okayama, H.; Masubuchi, H.; Yonekawa, T.; Watanabe, K.; Amino, N.; Hase, T., Loop-mediated isothermal amplification of DNA. Nucleic Acids res. 2000, 28, e63-e63. (19) Nagamine, K.; Hase, T.; Notomi, T., Accelerated reaction by loop-mediated isothermal amplification using loop primers. Mol. Cell. Probe. 2002, 16, 223-229. (20) Okuda, M.; Matsumoto, M.; Tanaka, Y.; Subandiyah, S.; Iwanami, T., Characterization of the tuf B-sec E-nus G-rpl KAJL-rpo B gene cluster of the citrus greening organism and detection by loop-mediated isothermal amplification. Plant Dis. 2005, 89, 705-711. (21) Li, W.; Hartung, J. S.; Levy, L., Evaluation of DNA amplification methods for improved detection of “Candidatus Liberibacter species” associated with citrus huanglongbing. Plant Dis. 2007, 91, 51-58. (22) Ravindran, A.; Levy, J.; Pierson, E.; Gross, D. C., Development of a loop-mediated isothermal amplification procedure as a sensitive and rapid method for detection of ‘Candidatus Liberibacter solanacearum’in potatoes and psyllids. Phytopathology 2012, 102, 899-907. (23) Mori, Y.; Nagamine, K.; Tomita, N.; Notomi, T., Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. Biochem. Bioph. Res. Co. 2001, 289, 150-154. (24) Goto, M.; Honda, E.; Ogura, A.; Nomoto, A.; Hanaki, K.-I., Short technical reports. Biotechniques 2009, 46, 167-172. (25) Tomita, N.; Mori, Y.; Kanda, H.; Notomi, T., Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat. Protoc. 2008, 3, 877-882. (26) Iwamoto, T.; Sonobe, T.; Hayashi, K., Loop-mediated isothermal amplification for direct detection of Mycobacterium tuberculosis complex, M. avium, and M. intracellulare in sputum samples. J. Clin. Microbiol. 2003, 41, 2616-2622. (27) Ball, C. S.; Light, Y. K.; Koh, C.-Y.; Wheeler, S. S.; Coffey, L. L.; Meagher, R. J., Quenching of unincorporated amplification signal reporters in Reverse-Transcription Loop-Mediated Isothermal Amplification enabling bright, single-step, closed-tube, and multiplexed detection of RNA viruses. Anal. Chem. 2016, 88, 3562-3568. (28) Njiru, Z. K.; Mikosza, A. S. J.; Armstrong, T.; Enyaru, J. C.; Ndung'u, J. M.; Thompson, A. R. C., Loop-mediated isothermal amplification (LAMP) method for rapid detection of Trypanosoma brucei rhodesiense. PLoS Negl. Trop Dis. 2008, 2, e147. (29) Kil, E.-J.; Kim, S.; Lee, Y.-J.; Kang, E.-H.; Lee, M.; Cho, S.-H.; Kim, M.-K.; Lee, K.-Y.; Heo, N.-Y.; Choi, H.-S., Advanced loop-mediated isothermal amplification method for sensitive and specific detection of Tomato chlorosis virus using a uracil DNA glycosylase to control carry-over contamination. J. Virol. Methods 2015, 213, 68-74. (30) Hsieh, K.; Mage, P. L.; Csordas, A. T.; Eisenstein, M.; Soh, H. T., Simultaneous elimination of carryover contamination and detection of DNA with uracil-DNA-glycosylase-supplemented loop-mediated isothermal amplification (UDG-LAMP). Chem. Commun. 2014, 50, 3747-3749. (31) Wu, X.; Meng, C.; Wang, G.; Liu, Y.; Zhang, X.; Yi, K.; Peng, J., Rapid and quantitative detection of citrus huanglongbing bacterium ‘Candidatus Liberibacter asiaticus’ by real-time fluorescent loop-mediated isothermal amplification assay in China. Physiol. Mol. Plant P. 2016, 94, 1-7. (32) Zhang, X.; Lowe, S. B.; Gooding, J. J., Brief review of monitoring methods for loop-mediated isothermal amplification (LAMP). Biosens. Bioelectron. 2014, 61, 491-499. (33) Hill, J.; Beriwal, S.; Chandra, I.; Paul, V. K.; Kapil, A.; Singh, T.; Wadowsky, R. M.; Singh, V.; 19

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457

Goyal, A.; Jahnukainen, T., Loop-mediated isothermal amplification assay for rapid detection of

458

Figure captions

459

Schemes 1 Schematic of LAMP-coupled visual detection method for field detection

460

of Las from leave samples within only 40 min.

461

Figure 1 Target sequence and primer locations for LAMP amplification. Nucleotide

462

positions are based on the sequence of Las encompassing a bacteriophage-type DNA

463

polymerase region (GenBank NO. M94302)

464

Figure 2 Sensitivity comparisons of real-time TaqMan PCR (a), real-time LAMP (b)

465

and LAMP-coupled visual detection method (c). Serial dilutions of purified DNA

466

extracted from symptomatic leaves ranging from 1.0 ×102 ng/µL to 1.0×10-5 ng/µL

467

(from left to right in each picture) were tested.

468

Figure 3 Visual detection of LAMP products. a) Fluorescent amplification curve of

469

LAMP amplification. b) Melting curve of LAMP amplification. c) Visual detection of

common strains of Escherichia coli. J. Clin. Microbiol. 2008, 46, 2800-2804. (34) Parida, M.; Horioke, K.; Ishida, H.; Dash, P. K.; Saxena, P.; Jana, A. M.; Islam, M. A.; Inoue, S.; Hosaka, N.; Morita, K., Rapid detection and differentiation of dengue virus serotypes by a real-time reverse transcription-loop-mediated isothermal amplification assay. J. Clin. Microbiol.2005, 43, 2895-2903. (35) Rigano, L. A.; Malamud, F.; Orce, I. G.; Filippone, M. P.; Marano, M. R.; Do Amaral, A. M.; Castagnaro, A. P.; Vojnov, A. A., Rapid and sensitive detection of Candidatus Liberibacter asiaticus by loop mediated isothermal amplification combined with a lateral flow dipstick. BMC Microbiol. 2014, 14, 86. (36) Wang, R.; Xiao, X.; Chen, Y.; Wu, J.; Qian, W.; Wang, L.; Liu, Y.; Ji, F.; Wu, J., A loop-mediated, isothermal amplification-based method for visual detection of Vibrio parahaemolyticus within only 1 h, from shrimp sampling to results. Anal. Methods 2017, 9, 1695-1701. (37) Kaneko, H.; Kawana, T.; Fukushima, E.; Suzutani, T., Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances. J. Biochem. Bioph. Meth. 2007, 70, 499-501. (38) Tomimura, K.; Miyata, S.-i.; Furuya, N.; Kubota, K.; Okuda, M.; Subandiyah, S.; Hung, T.-H.; Su, H.-J.; Iwanami, T., Evaluation of genetic diversity among ‘Candidatus Liberibacter asiaticus’ isolates collected in Southeast Asia. Phytopathology 2009, 99, 1062-1069.

20

ACS Paragon Plus Environment

Page 20 of 29

Page 21 of 29

Journal of Agricultural and Food Chemistry

470

positive and negative reactions at room temperature. d) Visual detection of LAMP

471

reaction mixture before amplification at room temperature. e) Visual detection of

472

positive and negative reactions at different temperatures.

473

Figure 4 Feasibility validation of LAMP-coupled visual detection method of Las. a)

474

Detection samples of one of the ten groups with 3 asymptomatic (A1, A2, A3) and 3

475

symptomatic leaves (S1, S2, S3). b) Visual detection for asymptomatic (A1, A2, A3) and

476

symptomatic (S1, S2, S3) samples. c) Results of real-time LAMP.

477

Figure 5 Detection result of 352 field samples in Zhejiang Province.

21

ACS Paragon Plus Environment

Journal of Agricultural and Food Chemistry

Page 22 of 29

Table 1 Datailed evaluation of NaOH-based DNA crude extraction from leave samples by real-time LAMP analyses. Tt Mean of each repeat

Mean of

Time for

Diluted

lysis (min)

multiples

Repeat 1

1

1

N

N

N

N

N

N

N

5

22.2

22.6

22.6

22.5

0.2

1.0

22.5

50

14.9

14.8

14.8

14.8 a

0.1

0.4

14.8

500

15.0

15.9

15.1

15.0

0.1

0.7

14.0

1

N

N

N

N

N

N

N

5

21.7

22.2

21.9

21.9

0.3

1.1

21.9

50

13.5

13.3

13.4

13.4 b

0.1

0.7

13.4

500

14.8

14.8

13.8

14.5

0.6

3.9

14.5

1

N

N

N

N

N

N

N

5

22.8

22.8

22.3

22.6

0.3

1.3

22.6

50

13.3

13.8

13.4

13.5 b

0.3

2.0

13.5

500

14.0

14.0

14.1

14.0

0.1

0.4

14.0

1

N

N

N

N

N

N

N

5

22.6

23.3

22.7

22.9

0.4

1.7

22.9

50

13.6

13.7

13.4

13.6 b

0.2

1.1

13.6

500

16.7

16.8

16.4

16.6

0.1

1.3

16.6

/

12.89

12.94

13.18

13.00 b

0.2

1.2

13.00

3

6

10

Commercial kit

Repeat 2

all

Repeat 3

SD

Tt values

RSD Time (%)

(min)

a, b The level of significant difference (p