Review of Advanced Materials for Proton Exchange Membrane Fuel

Oct 21, 2014 - ABSTRACT: The scientific community is focused on the development of inexpensive and high-performing membrane materials for proton ...
0 downloads 0 Views 4MB Size
Subscriber access provided by UNIVERSITY OF MICHIGAN LIBRARY

Review

A Review of Advanced Materials for Proton Exchange Membrane Fuel Cells Alexander Kraytsberg, and Yair Ein-Eli Energy Fuels, Just Accepted Manuscript • DOI: 10.1021/ef501977k • Publication Date (Web): 21 Oct 2014 Downloaded from http://pubs.acs.org on October 25, 2014

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

Energy & Fuels is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

A Review of Advanced Materials for Proton Exchange Membrane Fuel Cells Alexander Kraytsberg a and Yair Ein-Eli a, b, *

a - Department of Materials Science and Engineering; b - The Nancy & Stephan Grand Technion Energy Program (GTEP) Technion - Israel Institute of Technology, Haifa, 3200003, Israel * Corresponding author e-mail address: [email protected]

Keywords: Solid polymer electrolytes, Proton exchange membranes, Fuel cells

Abstract The scientific community is focused on the development of inexpensive and high-performing membrane materials for proton exchange membrane (PEM) fuel cells (FCs). The major approach to reducing the cost of FCs, which is crucial for the widespread acceptance of FCs as energy sources for various practical applications, is reducing the cost of the membrane. Efforts are being made in the development of advanced polymeric materials, which will satisfy the technical and economic demands of the consumers. Because most alternative membranes are outperformed by Nafion® membranes over an entire set of important properties, it may be worthwhile to compromise on certain parameters to develop alternative specialized membranes. This review paper presents the properties (mainly conductivity and chemical and mechanical stability) of modern solid polymer electrolytes (SPEs) for PEM FCs.

ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

1.

Introduction

Fuel cells (FCs) are electrochemical devices that produce electrical energy from the chemical energy of a fuel and oxygen. Although the most common fuel is hydrogen, other fuels, such as methanol, are also used. For the past five decades, FCs have been recognized as a preferred energy source for a wide variety of applications. Hydrogen contains more energy per unit weight than any other fuel, and therefore, a hydrogen-based power plant may be more efficient on a weight basis than a conventional power plant that uses other fuels; this aspect is particularly important for air, ground and marine transportation. Moreover, the advantage of direct electricity generation from hydrogen via a FC is evident if electrical energy is used directly (e.g., in domestic power supplies, communication equipment, electronic devices and portable electronics) rather than indirectly to generate mechanical movement. Since the 1960s, FCs have been used to power numerous mechanical and electronic systems, from spacecraft systems to electric vehicles, submarines and portable electronics. In a FC, hydrogen (or another fuel) is supplied to the anode side, whereas oxygen (pure oxygen or air) is supplied to the cathode side. At the anode, electrons are stripped from hydrogen atoms; the process is facilitated by a catalyst (e.g., platinum (Pt)-containing compounds). The produced protons pass through a proton-conducting electrolyte, whereas the electrons are directed through an external path, powering an attached device and leading to the cathode, reducing oxygen. At the cathode, the protons are combined with oxygen, forming water. Overall, the FC combines hydrogen and oxygen to produce water and electricity. The first FC was developed as early as 1839 by Sir William Robert Grove (1811-1896); at that time, his work was not considered for the development of a chemical power source but as a demonstration of a process, which was to invert electrolytic water decomposition. Sir Grove employed several electrolytic cells with separated anodic and cathodic compartments equipped with Pt electrodes and filled with a sulfuric acid-based electrolyte; the anodic 2 ACS Paragon Plus Environment

Page 2 of 80

Page 3 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

compartments contained gaseous hydrogen, and the cathodic compartments contained gaseous oxygen. He discovered that a voltage was generated between the electrodes of the cell and that several of these cells connected in series comprised a battery that produced a voltage that was sufficiently high to decompose water.[1] The original drawing of Sir Grove's experiment is presented in Figure 1.

Figure 1. Grove's drawing of his wet cell, or "gas battery" (acquired from [1]).

Further research explaining how these "gas cells" actually work was conducted for over a century by Christian Schönbein,[2] Friedrich Wilhelm Ostwald,[3] Ludwig Mond,[4] Charles R. Alder Wright,[5] William W. Jacques,[6] Emil Bau,[7] and Francis Thomas Bacon.[8,

9]

The

construction of the first practical and operational FC is commonly attributed to the Francis Thomas Bacon. Research continued during World War II but with few practical implementations. In the early 1950s, military demands for a robust power supply for space and mobile applications began to promote the idea of producing electricity via an electrochemical process that utilized atmospheric or stored oxygen and employed a device without moving parts. Because these technological improvements were designed for space and military applications, the research costs were often of secondary importance. Because air is not available in space or underwater and it is impractical to store oxygen for internal 3 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

combustion engines, chemical power sources (i.e., batteries) may serve as reliable power sources. The conventional batteries of the 1950s were extremely heavy. This fact stimulated NASA to develop FCs as a provisional chemical power source. The full implementation of FCs in submarines required an additional 40 years, with the first non-nuclear, air-independentpropulsion submarines entering service in European fleets in the early 2000s. FCs with solid polymer electrolyte (SPE) membranes separating the anodic (fuel) compartment from the cathodic (oxidant) compartment were first introduced in the Gemini space program in the early 1960s. Those cells were expensive and had short lifetimes due to the poor stability of the SPE membranes. The sulfonated polystyrene-divinylbenzene membranes suffered from rapid oxidative degradation. Additionally, this material was prohibitively expensive for practical commercial applications.

Figure 2. Annual FC system shipments worldwide (acquired and modified from [10]). 4 ACS Paragon Plus Environment

Page 4 of 80

Page 5 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Commercial applications of FCs gradually became more attractive over the past five decades. This acceptance was primarily driven by the growing demand for environmentally friendly power plants, for vehicle and stationary energy applications (see Figure 2), zero-emission power sources for confined environments and high energy density power sources for mobile devices. The major types of FCs are schematically presented in Figure 3. FCs are classified by the type of electrolytes they use. Table 1 presents a comparison of different FC technologies.

Figure 3. Summary of FC types.

5 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 80

Polymer electrolyte membrane (PEM) FCs are considered the optimum FC for applications such as backup power sources, power sources for portable electronics, distributed power generation and electric vehicles. An exemplified structure of a PEM FC is shown in Figure 4.

Table 1. Comparison of FC technologies.[11]

Fuel Cell

Common

Operating

50-100°C Polymer Electrolyte PerfluoroMembrane sulfonic acid (PEM)

122-212° typically 80°C

Alkaline (AFC)

Aqueous solution of potassium hydroxide soaked in a matrix

Phosphoric Phosphoric Acid acid soaked (PAFC) in a matrix

Typical Stack

Efficiency

Applications

60%

• Backup power • Solid electrolyte reduces corrosion & electrolyte transportatio • Portable management < 1–100 kW n power problems • Distributed 35% generation • Transportation • Low temperature

90-100°C

• Military 10–100 kW

60%

194-212°F

• Space

150-200°C 400-100 kW

• Distributed generation

40% 302-392°F

Advantages

modules

Disadvantages

• Expensive catalysts • Sensitive to fuel impurities • Low temperature waste heat

• Cathode reaction faster • Sensitive to C O 2 in alkaline electrolyte, in fuel and air leads to high performance • Electrolyte management • Low cost components

• Higher temperature • Pt catalyst enables CHP • Increased tolerance to • Long start-up time • Low current and fuel impurities power • High efficiency

Solution Molten Carbonate (MCFC)

of Li, Na and/or K carbonates, soaked

0.3 – 3 MW • Fuel flexibility

600-700°C

• Electric utility 45-50%

1112-1292°F

300 kW

• Distributed generation

(SOFC)

• Auxiliary power • Fuel flexibility Yttria stabilized zirconia

700-1000°C 1 kW–2 MW 1202-1832°F

• Long start-up time • Low power density

• Suitable for CHP • High efficiency

module Solid Oxide

• Can use a variety of catalysts

• High temperature corrosion & breakdown of cell components

60%

• Electric utility • Distributed generation

• Can use a variety of catalysts • Solid electrolyte

• High temperature corrosion and breakdown of cell components • High temperature operation requires long start-up time

A practical FC-based power source is composed of an FC stack (as presented in Figure 5) and auxiliary devices (e.g., manifolds, humidifiers, air pumps, and thermal controls). The FC stack 6 ACS Paragon Plus Environment

Page 7 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

is in turn composed of a membrane electrode assembly (MEA) and bipolar plates, which serve as current collectors and supply reagents to the MEA electrodes. Bipolar plates also electrically connect multiple MEAs in series.

Figure 4. Schematic representation of a PEM FC design (acquired and modified from [12]).

Figure 5. PEM FC stack (acquired and modified from [13]). 7 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Many important PEM FC features depend on the properties of the PEM. The important properties of the SPE for a PEM are:



High proton conductivity;



Low electronic conductivity;



Low fuel and oxidant permeability;



adequate electrochemical and chemical stability in a real (i.e., a highly aggressive) FC environment;



high stability under FC operation conditions, i.e., the SPE should have good thermal and hydrolytic stability (water and peroxides are the reaction products in a FC);



significant dimensional and morphological stability;



adequate water transport (diffusion and electro-osmotic) properties because the protontransporting properties of most PEMs depend on the membrane hydration;



good mechanical properties in all hydration states; this feature is essential for the reliable operation of the MEA and facilitates the FC manufacturing process;



a sufficiently long lifetime under FC operation conditions; and



a satisfactorily low cost. Indeed, the PEM is the largest contributor to the overall FC cost (see Figure 6). The current shipment statistics indicate that less than 1,000 pieces of 80-kW PEM FCs are shipped per year, which can also be inferred from the data presented in Figure 2 (PEM FCs account for approximately 90% of all FC shipments).[10]

8 ACS Paragon Plus Environment

Page 8 of 80

Page 9 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Figure 6. Breakdown of the 2013 projected FC stack cost at 1,000/year production of 80-kW systems (data acquired from [14]).

For portable applications, a methanol FC (direct methanol FC, DMFC) is currently being considered as a promising power source. A low rate of methanol crossover is a requirement for such FCs. Methanol diffusion from the anode to the cathode results in cathode depolarization and thus lowers the cell voltage efficiency and reduces the fuel efficiency of the system. Methanol is also poisonous for many cathode catalysts. A few extensive reviews on SPE materials are available, and the reader is kindly directed to them.[15-24] The present work aims to discuss recent developments in the field of practical and viable SPE materials for H2/O2 PEM FCs and DMFCs.

2.

Poly [perfluorosulfonic acid] (Nafion®)-type Membranes

2.1. Introduction The use of organic cation exchange membrane polymers in FCs was originally developed in 1959 by GE researcher Willard T. Grubb.[25, 26] The intended function of the membrane was to provide a proton-conducting gas barrier. Strong acids were used to provide contact between 9 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

the membrane and catalytic surfaces. Further development demonstrated that the cell could function well without the acid contact layer; at present, PEM FCs do not use any electrolytes other than the membrane itself. In the 1960s, the membrane was found to be a key factor in the FC because the PEM acts an electrolyte and the structure of the PEM/[electrode catalyst] interface controls the reaction kinetics. From this understanding, a substantial part of the FCrelated research was focused on improving PEM properties, developing a stronger, more durable and flexible SPE, and increasing SPE proton conductivity. Currently, Nafion® is the PEM that serves as a benchmark in the FC industry. This material was developed in the late 1960s by Dr. Walther Grot from DuPont (this material was originally suggested to be employed as a perm-selective separator in chloro-alkali electrolyzers).[27] Nafion® was developed by modifying another DuPont product, Teflon®,[28] which was the first synthetic polymer with ionic properties (ionomers) ever developed. Ionic properties are impelled to Nafion® by adding a pendant sulfonic acid group into the polymer backbone. The exemplified structure of Nafion® is shown in Figure 7, where the sulfonic acid group is shown in its anhydrous form, SO3H. When exposed to water, the hydrolyzed form (SO3-H3O+) appears, allowing for proton transport across the material.

Figure 7. Nafion® formula (acquired and modified from [29]).

10 ACS Paragon Plus Environment

Page 10 of 80

Page 11 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

Commercial Nafion® 1100 EW membranes with thicknesses of 2, 5, 7, and 10 mil (1 mil = 25.4 µm; Nafion® 112, 115, 117, and 1110, respectively) appear to be the most widely used grades of Nafion®. This material provides high proton conductivity and moderate water swelling. The thinner membranes are generally applied to hydrogen/air applications to minimize ohmic losses, whereas the thicker membranes are employed for DMFCs and to reduce methanol crossover.[22] Being similar to Teflon®, Nafion® exhibits excellent resistance to chemical attacks and an extremely low release rate of degradation products into the surrounding medium; it also has a relatively high operation temperature range and may be used in many applications at temperatures of up to 190°C. Nafion® has a high proton conductivity and acts as a super-acid catalyst because its sulfonic acid groups act as an extremely strong proton donor. The interaction of sulfonic acid groups with water results in rapid water absorption and water transport through the Nafion® material.

2.2. Nafion® membrane conductivity Hydrophilic sulfonic groups, which are side-attached to the fluorinated hydrophobic backbone of Nafion®, may be subjected to hydration, i.e., water molecules may accumulate around these groups. Water affects the Nafion® proton conductivity by controlling the formation, dimensions, and connectivity of proton pathways in Nafion®. As more water molecules become available, these water clusters grow in size, and the Nafion® material separates into hydrophobic regions and water-filled hydrophilic domains.[30-35] Nafion® with a low water content contains only small isolated water clusters and behaves as an insulator. Eventually, a percolation threshold of proton conductivity is passed. At that point, the water clusters are connected in a random network embedded in a continuous, sponge-like fluorocarbon phase.

11 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

However, most of the water molecules are still located at the borders of the clusters, and thus, most of the water molecules inside the percolation channels are accumulate in sulfonate group solvation shells. This leads to a high activation energy for proton transfer, which impedes a "hop-turn" (i.e., Grotthuss-type) proton conductivity and results in a primarily proton diffusion-based conductivity. At the same time, the low proton mobility results in small proton conductivity. As the water content increases, the channels become broader, and more free water molecules become available. However, the strong electrostatic interaction between the hydronium ions and multiple sulfonate groups still impedes Grotthuss-type proton conductivity and results in a predominantly diffusion-based proton conductivity. Under this hydration state, proton mobility is a key factor that determines the proton conductivity. As the water content increases, the water clusters and channels increase in size, and the amount of available free water inside the aqueous phase increases. This results in an increasing dominance of the Grotthuss-type conductivity, which increases proton transport capabilities. Once Nafion® becomes fully saturated with water, its structure is patterned with highly interconnected water channels and nearly spherical small hydrophilic domains containing water drops. These nearly spherical domains are surrounded by the hydrophobic polymer backbone chains, with the hydrophilic ionic groups located at the interface. A welldeveloped percolated network is formed, with the network comprising channels filled with free water. Thus, a saturated Nafion® membrane resembles a phase-separated system containing hydrophobic main chain agglomerates and hydrophilic water/acid segments. The proton conductivity of the Nafion® membrane approaches a value close to the conductivities of bulk aqueous electrolytes, and the conductivity is controlled by a Grotthuss-type mechanism. DuPont’s Nafion® is not entirely unique, and similar perfluorinated ionomers have been developed by other companies (e.g., Aciplex® and Flemion® of Asahi Chemical Company).[36-38] Nafion®-type perfluorinated ionomers with shorter pendant groups (such as 12 ACS Paragon Plus Environment

Page 12 of 80

Page 13 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

AQUIVION™ of Solvay Solexis) are also currently marketed and appear to outperform Nafion®, having a lower methanol crossover and superior water management.[39, 40]

2.3. Nafion® membrane drawbacks Although Nafion® currently dominates the market, particularly in FC design and production,[41] it has some serious drawbacks.



Because the proton conductivity is determined by the water-filled channels, Nafion® is not adequate for temperatures materially lower than 0°C or over 100°C. [42, 43]



Nafion® is seemingly stable against peroxide-type ion and radical degradation (which are intermediate products of the reactions at the electrodes of the FC),[44] e.g., it is stable against 30% H2O2 even at 80°C. However, alien cations (i.e., other than H+) are known to catalyze the polymer chain decomposition.[45, 46] Additionally, a few of the hydrogen-containing terminal groups of the polymer are susceptible to peroxide radical attacks.[47] Contaminating ions, especially multi-charged ions,[44,

48]

may also drastically decrease the

membrane conductivity and decrease the water content of the Nafion® membrane.[44, 49] Thus, alien ion impurities should be minimized during membrane production and operation.



Nafion® has poor mechanical and chemical stabilities at elevated temperatures.[50-53] Because it is a part of an assembled MEA, the membrane suffers from severe degradation over the course of multiple thermal and hydration/dehydration cycles.[54-56] Because membrane mechanical degradation is typically the limiting parameter in determining FC lifetimes, substantial efforts were made to avoid or at least minimize this type of degradation. The membrane operational life also depends largely on the MEA design and MEA assembly 13 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 80

process.[57-59] The appropriate routes for improving the mechanical stability of a Nafion® membrane are through the precise controls of membrane swelling, temperature and temperature gradient[36, 60-63] and the reinforcement of the membranes with an inert matrix,[6466]

which may be composed of a polymer structure[36,

50, 67-75]

or an inorganic matrix.

Composite membranes comprising Nafion® and inorganic fillers have been used. These are generic methods to improve the membrane chemical and temperature stabilities but are less commonly used to enhance the membrane mechanical stability.[36, 65, 76-82] The introduction of a reinforcing matrix typically decreases the membrane specific conductivity and water vapor permeability. These changes appear because a part of Nafion® is substituted with the matrix material, which is impermeable to water and protons. The effects of the matrix extend beyond a simple substitution of a portion of an active material with inert media. An inert matrix-coated Nafion® membrane may have lower proton conductivity and water vapor permeability than bulk Nafion® due to a decrease in the membrane connectivity and because of the matrix-restricted macromolecular transport.[70] However, several additives may be used to enhance the proton conductivity of the reinforced Nafion® membranes (e.g., phospho-tungstic acid).[83] The employment of a reinforcing matrix may result in an increase in the overall membrane conductivity because the reinforced membrane may be substantially thinner than the Nafion® membrane.[60] The presence of inorganic fillers with grafted functional groups is more efficient and enhances the overall composite membrane properties, such as water uptake, ion exchange capacity (IEC), and conductivity, while maintaining the mechanical properties of the composite membrane. The shape of the inorganic fillers also strongly affects the properties of the composite membranes.[84] Surface treatments may also result in improved mechanical properties.[85, 86]



Nafion® has insufficient resistance to methanol crossover. This feature stems from the fact 14 ACS Paragon Plus Environment

Page 15 of 80

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Energy & Fuels

that although the water-filled network provides for proton transfer, it also provides a route for methanol diffusion. This drawback of Nafion® may be addressed by the addition of fine inorganic particles to the polymer matrix.[87] Another way to overcome the high methanol permeability of Nafion® is to introduce other polymers with different properties inside the voidspace.[88] There are two approaches to such a modification: the first approach suggests the introduction of individual polymer molecules inside the voidspace (i.e., semi-interpenetrating polymer networks, or a semi-IPN architecture);[88,90] the second approach suggests the introduction of an interconnected polymer net comprising cross-linked polymer molecules (i.e., interpenetrating polymer network, or IPN).[91] The high methanol permeability of Nafion® is an issue, particularly if a PEM DMFC uses only this membrane.



The cost of a SPE is critical from a practical perspective. Nafion® membranes are prohibitively expensive due to their complex manufacturing process.

3.

Non-Nafion® SPE

The development of Nafion® in the early 1960s was followed by a significant decline in the development of non-Nafion® SPE materials in subsequent decades. However, the aforementioned drawbacks (particularly the high price of Nafion®) has become a driving force for the development of new polymer electrolytes, which are expected to be more affordable, more mechanically and chemically stable, and less permeable to methanol compared to Nafion®. There has also been a growing demand for materials capable of operating at high (>100°C) and medium (>80°C) temperatures with high conductivity at low hydration levels. The operation of FCs at elevated temperatures offers several substantial advantages.[20, 40, 92-95] First, the commonly used Pt-based catalysts are poisoned by carbon monoxide (CO) at low operational temperatures; unfortunately, CO is often present in fuel-grade H2. This requires an 15 ACS Paragon Plus Environment

Energy & Fuels

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

expensive H2-fuel purification process for PEM FCs. At high temperatures (particularly at temperatures above approximately 160°C), catalyst poisoning does not occur, and the cell may tolerate up to 3% CO in the H2 fuel without significant power losses.[40, 96] Second, faster electrode kinetics are expected at elevated temperatures, which increases the FC efficiency. Third, the absence of bi-phasic water (vapor and liquid) simplifies water management. Modern SPE-related research is focused on the following areas:

a. developing SPEs for H2/O2 FCs with high operation temperatures; such SPEs are expected to operate under low-humidity conditions;

b. developing SPEs for DMFCs with high protonic conductivity but low methanol permeability; and

c. develop low-cost substitutes for Nafion®-type membranes. Numerous partially fluorinated SPE and non-fluorinated (hydrocarbon) SPE materials have been investigated[97] ([98] provides an extensive review of methods using such SPEs). These SPE materials have similar proton conductivity mechanisms as Nafion®. However, these materials may potentially offer advantages over Nafion® depending on the presence of water inside the polymer[99-101], the specifics of production costs, water management, methanol crossover and thermal cycling stability.

3.1. Polystyrene-Based Membranes Polystyrene-sulfonic-acid (PSSA) membranes were the first commercial polymer membranes [25]

(see Figure 8). The first polystyrene membranes were developed in 1955 by GE and were

used in the first-ever operational PEM FC (the Grubb-Niedrach FC) in the Gemini program.[102, 103] However, the system exhibited a short lifetime (