Subscriber access provided by Fudan University
Article
Selection and Characterization of DNA Aptamers for Electrochemical Biosensing of Carbendazim Mohammed M. Zourob, and Shimaa Hassan Hassan Eissa Anal. Chem., Just Accepted Manuscript • DOI: 10.1021/acs.analchem.6b04914 • Publication Date (Web): 24 Jan 2017 Downloaded from http://pubs.acs.org on January 26, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Analytical Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
Selection and Characterization of DNA Aptamers for Electrochemical
2
Biosensing of Carbendazim
3 4
Shimaa Eissaa, Mohammed Zouroba,b*
5
6
a
7
Road, Riyadh 11533, Saudi Arabia
8
b
9
12713, Saudi Arabia
Department of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, Al Takhassusi
King Faisal Specialist Hospital and Research Center, Zahrawi Street, Al Maather, Riyadh
10
11 12 13 14 15 16 17 18 19
*Corresponding author:
20
[email protected] 21 22
1 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1 2
Abstract:
3
This article reports a novel aptamer-based impedimetric detection of carbendazim, a commonly
4
used benzimidazole fungicide in agriculture. High affinity and specificity DNA aptamers against
5
carbendazim were successfully selected using systematic evolution of ligand by exponential
6
enrichment (SELEX). The dissociation constants (Kds) of the selected DNA aptamers after ten in
7
vitro selection cycles were characterized using fluorescence-based assays showing values in the
8
nanomolar range. The aptamer which showed the highest degree of affinity and conformation
9
change was used to fabricate an electrochemical aptasensor via self assembly of thiol-modified
10
aptamer on gold electrodes. The aptasensor exploits the specific recognition of carbendazim by
11
the aptamer immobilized on the gold surface which leads to conformational changes in the
12
aptamer structure. This conformational change alters the access of a ferrocyanide/ferricyanide
13
redox couple to the aptasensor surface. The aptasensor response is thus, measured by following
14
the increase in the electron transfer resistance of the redox couple using Faradic electrochemical
15
impedance spectroscopy. This method allowed a selective and sensitive label-free detection of
16
carbendazim within a range of 10 pg/ml-10 ng/ml with a limit of detection of 8.2 pg/ml . The
17
aptasensor did not show cross reactivity with other commonly used pesticides such as
18
fenamiphos, isoproturon, atrazine, linuron, thiamethoxam, trifluralin, carbaryl and methyl
19
parathion. Moreover, the aptasensor has been applied in different spiked food matrices showing
20
high recovery percentages. We believe that the proposed aptasensor is a promising alternative to
21
the currently used methods for carbendazim monitoring.
22
23
2 ACS Paragon Plus Environment
Page 2 of 33
Page 3 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1 2 3 4
Introduction
5
activity for protecting plants such as fruits, vegetables and cereals from pathogens. However, the
6
extensive use of pesticides in agriculture leads to their accumulation inside the plants which
7
represents a serious risk to human health. Because of the high stability of the benzimidazolic ring
8
in CBZ 1, it persists for long time in the soil and gets absorbed by the plants via the roots, seeds
9
or leaves entering the food chain. Studies
Carbendazim (CBZ) is the most widely used benzimidazole fungicide that shows long term
2-3
have shown the potential toxicity of CBZ on both
10
humans and animals. CBZ affects dehydrogenase and phosphatase activities 4, may cause
11
infertility in males 5, alters hormones concentrations and can cause disruption in the endocrine
12
system 6. Thus, the sensitive and accurate detection of CBZ in various food commodities has
13
become increasingly important for the protection of the public health.
14
Several traditional methods are currently used for the detection of the CBZ such as 7-9
, liquid chromatography coupled with mass spectrometry
10-11
15
chromatography
16
electrophoresis
17
spectroscopy
18
they cannot be used for on-site monitoring of CBZ because of the high cost and large size of the
19
used instruments as well as the long analysis time. Moreover, interference from other
20
components of the food complex matrix may not allow the precise detection of CBZ, thus sample
21
purification is usually required prior to analysis. Several electroanalytical methods have been
22
also used for the detection of CBZ exploiting its inherent electroactivity. The electrochemical
23
detection of CBZ has been reported using different electrode materials such as phosphorus-doped
24
helical carbon nanofibers
25
modified with graphene oxide/ carbon nanotubes hybrid material
12-13
19-20
, surface enhanced Raman scattering
and chemiluminescence
22
21
14-15
, fluorescence
16-18
, capillary
, UV-visible
. These methods are relatively sensitive; however,
, boron-doped diamond electrode
3 ACS Paragon Plus Environment
23 24
, glassy carbon electrodes or montmorillonite clay
25
,
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 4 of 33
26
1
multi-walled carbon nanotubes-polymeric methyl red film modified electrode
2
cyclodextrin/graphene hybrid nanosheets
3
powerful than other assays due to their low cost, ease of use, sensitivity and short analysis time.
4
However, other electrochemically active pesticides which are used concomitantly with CBZ in
5
various fields such as isoproturon
6
analysis. Therefore, the selective detection of CBZ in real samples is hardly achievable using the
7
reported electrochemical sensors that does not use a specific recognition receptor. Itak et al.
8
have reported the production of specific antibodies against CBZ and its application in magnetic
9
particle-based immunoassay. Enzyme linked immunosorbent assay (ELISA) kit for CBZ is
10
commercially available. The immunoassays have better selectivity and capability of high
11
throughput analysis of CBZ. However, the production of the antibodies for CBZ and other
12
pesticides is challenging as they are small molecules which have to be conjugated with carrier
13
proteins for immunization 31. Moreover, the haptens which are usually used as immunogens and
14
for coating in ELISA have to be synthesized from CBZ analogs in order to attach appropriate
15
function groups to the molecule to enable the conjugation with the protein
16
high cost and low stability of the antibodies limits the wide applicability of the immunoassays
17
for CBZ detection. Therefore, more stable, specific and cost effective recognition receptor for
18
CBZ is strongly needed to be employed in biosensing platforms in order to replace the old
19
technologies.
28
27
and
. The electrochemical methods appeared to be more
and fenamiphos
29
can interfere with CBZ complicating the
32
30
. Additionally, the
20
Aptamers are synthetic single stranded DNA (ssDNA) or RNA which can be identified
21
using in vitro selection protocol. Aptamers have appeared as promising alternatives to the
22
traditional antibodies showing high affinity and specificity. Unlike antibodies, aptamers are
23
highly stable at any condition and can be easily synthesized with very low cost. They can be also
4 ACS Paragon Plus Environment
Page 5 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
selected against low molecular weight analytes which are hard to produce antibodies for. Despite
2
the successful selection of aptamers against various small molecules
3
hormones37-38 and antibiotics
4
reported on the use of aptamers for the detection of organophosphorous pesticides 41-43. Here, we
5
report for the first time the selection of high affinity and specificity DNA aptamers for CBZ. The
6
application of the selected aptamer in a label-free biosensor using electrochemical impedance
7
spectroscopy detection is also presented. The combination between the high specificity and
8
affinity of the new aptamer and the sensitivity of the impedance technique enabled the rapid, low
9
cost and reliable detection of CBZ.
39-40
33
such as toxins
34-36
,
, aptamers for pesticides are very rare. Few studies have been
10 11
EXPERIMENTAL SECTION
12
Materials and reagents
13
Carbendazim, potassium ferricyanide (K3Fe(CN)6), potassium ferrocyanide (K4Fe(CN)6),
14
methanol, sodium chloride, potassium dihydrogen orthophosphate, 6-Mercapto-1-hexanol
15
(MCH), dipotassium hydrogen orthophosphate, acetonitrile and magnesium chloride were
16
obtained from Sigma (Ontario, Canada). Atrazine, linuron, thiamethoxam, trifluralin, carbaryl,
17
methyl parathion, fenamiphos and ioproturon were obtained from the food safety laboratory
18
(Qassim, KSA). The polymerase chain reaction (PCR) primers and the DNA library were
19
custom-synthesized by Integrated DNA Technologies Inc. (Coralville, USA). The thiol modified
20
aptamers
21
/SH/CGACACAGCGGAGGCCACCCGCCCACCAGCCCCTGCAGCTCCTGTACCTGTGTG
22
TGTG/-3'
23
/SH/GGGCACACAACAACCGATGGTCCAGCCACCCGAATGACCAGCCCACCCGCCAC
(CZ12:
and
5´-C6
CZ13:
5 ACS Paragon Plus Environment
5´-C6
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
CCCGCG/ -3') were synthesized by Metabion (Planegg, Germany). CBZ ELISA test kit was
2
obtained from Bioo Scientific (Austin, USA). Taq plus DNA polymerase, urea, Tris-base, boric
3
acid, acrylamide/bis-acrylamide (40 % solution) and EDTA disodium dehydrate were obtained
4
from Bioshop Inc. (Ontario, Canada). Cellulose acetate centrifuge tube filters (pore size: 0.45
5
µm) were purchased from Corning life sciences (Tewksbury MA, USA). TOPO TA Cloning Kit
6
with One Shot MAX Efficiency DH5α-T1 was obtained from Invitrogen (NY, USA). Amicon
7
Ultra-0.5 mL centrifugal desalting filters with a 3kDa molecular cut-off were purchased from
8
EMD Millipore (Alberta, Canada). The CBZ solution was prepared by dissolving in methanol
9
(3µg/ml) and then diluted with binding buffer in order to obtain the working solutions. All the
10
pesticide solutions which were used for cross reactivity were prepared in acetonitrile (1mg/ml)
11
and diluted with binding buffer. Tris-EDTA buffer (TE buffer) is 10 mM Tris, pH 7.4, 1 mM
12
EDTA. The binding buffer which was used for the SELEX and detection experiments consists of
13
50 mM Tris, pH 7.5, 150 mM NaCl and 2 mM MgCl2. The Elution buffer consists of 7 M urea in
14
binding buffer. A phosphate buffered saline PBS solution (10 mM, pH 7.4) was used to dissolve
15
the [Fe(CN)6]3−/4− redox couple for the electrochemical measurements. The mango juice, soya
16
milk, tomato and plum samples were obtained from local store (Riyadh, KSA). All the solutions
17
were prepared using Milli-Q grade water.
18
Instrumentation
19
The ultraviolet-visible (UV) and fluorescence measurements were recorded using
20
NanoDrop 2000C Spectrophotometer and NanoDrop 3300 Fluorospectrometer, respectively
21
(Fisher Scientific, Canada). The ELISA measurements were performed using microplate reader
22
(Sunnyvale, USA). Electrochemical experiments were carried out using an Autolab
23
PGSTAT302N potentiostat (Eco Chemie, The Netherlands) controlled by 1.11 NOVA software.
6 ACS Paragon Plus Environment
Page 6 of 33
Page 7 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
A three-electrode cell was used for all the electrochemical measurements, consisting of a
2
standard gold working electrode, an Ag/AgCl reference electrode and a platinum wire as counter
3
electrode.
4 5
Methods
6
In vitro selection protocol of the DNA Aptamer for CBZ
7
The selection of the aptamer was carried out using the protocol reported previously
34
. A
8
random ssDNA library (1.8 × 1015 oligonucleotides) was used for the aptamer selection which
9
consists of a central random region of 60 nucleotides flanked by two primer annealing sites of 18
10
nucleotides
at
the
3’
and
5’
ends
(5’-ATACCAGCTTATTCAATT
11
AGATAGTAAGTGCAATCT-3’). The DNA library was dissolved in binding buffer. A
12
pretreatment of the DNA solution was done before each round by heating it to 90°C for 5
13
minutes, then cooling at 4°C for 10 minutes and keeping at 25°C for 5 minutes. Two hundred µl
14
of the pretreated DNA which contain 3 nmol DNA in the first round and 150 pmol in the
15
subsequent rounds were added to the CBZ-bovine serum albumin (CBZ-BSA) coated wells of
16
the ELISA microtiter plate. Two wells were used for each round and 100 µl DNA solutions were
17
added to each well and incubated with mild shaking for 2 h. at room temperature (the incubation
18
time was gradually decreased in the subsequent rounds in order to increase the stringency of the
19
selection as shown in Table S1). After that, the unbound and the weekly bound DNA to CBZ
20
were removed by washing the wells for 3 times with binding buffer. Then, the bound DNA to
21
CBZ was eluted in the first seven rounds by incubation with preheated 100µL elution buffer in
22
each well for 6 times with continuous heating at 90°C for 10 minutes. After the seventh round,
23
specific elution was performed (the bound DNA was eluted by incubation with 10 mM CBZ
7 ACS Paragon Plus Environment
-
N60-
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 8 of 33
1
solution for 30 min.) and the binding time was decreased from 45 to 30 min. Then, the eluted
2
aliquots were concentrated and desalted by ultrafiltration using Amicon filters. The purified
3
DNA pool after elution was then PCR amplified using 15 parallel reactions of 75µL each
4
contains 2 units of Taq Plus polymerase enzyme, Taq buffer, 2mM MgCl2, 200µM dNTP,
5
0.2µM of forward and reverse primers. The primers sequences were modified with fluorescein
6
and a polyethylene glycol (PEG) spacer linked to poly-A tail as reported previously
7
Forward primer is 5’-fluorescein-ATACCAGCTTATTCAATT-3’ and reverse primer is 5’-
8
poly-dA20-PEG6-AGATTGCACTTACTATCT-3’. PCR thermal cycle conditions were 94°C for
9
10 minutes, followed by 25 cycles of 94°C for 1 minute, 47°C for 1 minute, 72°C for 1 minute,
10
and a final extension step of 10 minutes at 72°C. The double stranded DNA (dsDNA) solution of
11
the product PCR was dried by SpeedVac, then resuspended in 50:50 water and formamide and
12
heated to 80°C for 2 minutes. Denaturing polyacrylamide gel electrophoresis (PAGE), 12% was
13
used to separate the relevant fluorescent ssDNA strand (aptamer) from the dsDNA PCR product.
14
The fluorescent DNA was then eluted from the gel band by freeze-thaw cycle in TE buffer (the
15
gel slices were crushed into small pieces using a syringe and suspended into 3 ml of TE buffer,
16
then frozen at -80 oC for 10 mins, thawed at 60 oC for 5 min and then heated at 90 oC for 5 min.).
17
The product was then concentrated, desalted, quantified by measuring the UV using Nanodrop
18
device and used for the subsequent selection cycle.
34,36
.
19
Cloning and sequencing of the selected DNA for CBZ
20
After ten selection rounds when the recovered DNA began to plateau, the SELEX was stopped
21
and the obtained DNA pool from the last round was PCR amplified with unmodified primer set
22
and cloned into pCR2.1-TOPO vector using TOPO TA Cloning Kit. The E Coli competent cells
23
were grown on LB-agar plates supplemented with ampicilin, X-Gal and IPTG. Positive colonies
8 ACS Paragon Plus Environment
Page 9 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
(white color) were picked and grown in LB liquid media. The ssDNA inserts (aptamers) were
2
amplified using the M13 forward and reverse primer sites within the vector and sequenced. The
3
identified CBZ specific aptamers were the aligned via PRALINE 44 software Fig. S1.
4 5
Binding assays of the CBZ aptamers using fluorescence detection
6
The fluorescence binding affinity studies were realized following the previously reported
7
protocol 34. Six of the sequenced aptamers were synthesized with fluorescein modification at the
8
5' end after eliminating the primers sequences and their binding affinities to CBZ were tested.
9
First, the aptamers were pretreated by heating and cooling as previously described in the SELEX
10
part. Then 100 µl solution of each aptamer of different concentrations (25, 75, 100, 150, 300 nM)
11
in binding buffer were incubated on the CBZ-BSA coated wells and incubated for 30 min. with
12
mild shaking at room temperature and protected from light. After binding, the wells were washed
13
with binding buffer and then the bound DNA aptamers to the CBZ were eluted using preheated
14
elution buffer at 90 oC for 10 min. The DNA library was used as a control. The assay was
15
performed in duplicate.
16
In order to determine the dissociation constants of the aptamers with CBZ, binding assays were
17
performed as described above, but using different concentrations of the fluorescent aptamers (25
18
to 300 nM). Then, the fluorescence intensity of the eluted DNA in each sample was measured
19
and used to plot the binding curves. The Kd for each CBZ aptamer was determined by non-linear
20
regression analysis of the binding curve.
21
CBZ aptasensor fabrication
22
Before modification, standard gold electrodes (2 mm in diameter) were polished with alumina
23
slurries with various particle sizes (1.0, 0.3, and 0.05 µm), and washed with Milli-Q water. Then
9 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 10 of 33
1
the electrodes were cleaned with piranha solution, followed by cyclic voltammetry (CV)
2
cleaning in 0.1 M H2SO4 by scanning between 0.2 and 1.6 V for 5 min, then washed with
3
ultrapure water and dried under nitrogen stream. The cleaned electrodes were then incubated in 1
4
µM of thiol modified CZ13 or CZ12 aptamers in binding buffer for 24 h. After the
5
immobilization, the electrodes were washed with Tris-HCl, pH 7.4 and then incubated with 1
6
mM MCH in PBS buffer for 30 min. The aptamer-modified Au electrodes were rinsed
7
thoroughly with binding buffer and used immediately in the electrochemical experiments or
8
stored in binding buffer solution at 4 °C.
9
Electrochemical measurements
10
For the CBZ detection experiments, 10 µL droplet of CBZ solution of certain concentration
11
(0.01, 0.1, 1.0, 10, 100, 100 and 1000 ng/ml) in binding buffer were incubated onto the
12
aptasensor surface for 30 min. After incubation, the electrodes were washed with Tris-HCl, pH
13
7.4 buffer to remove the nonspecifically bound molecules and then the electrochemical
14
measurements were recorded. The selectivity experiments were performed by incubating the
15
aptasensors with 100 ng/ml of atrazine, linuron, thiamethoxam, trifluralin, carbaryl, methyl
16
parathion, fenamiphos, ioproturon or CBZ. The sensors were then washed and subjected to the
17
measurements.
18
The CV experiments were performed at a scan rate of 100 mV/s. The electrochemical
19
impedance spectroscopy (EIS) measurements were recorded over a frequency range from 10 kHz
20
to 0.1 Hz using an alternative voltage with amplitude of 10 mV, superimposed on a DC potential
21
of 0.20 V (vs Ag/AgCl reference electrode). The impedance data were plotted as Nyquist
22
diagrams with a sampling rate of 25 points per decade. The impedance spectra were fitted using
10 ACS Paragon Plus Environment
Page 11 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
NOVA 1.11 software. All the electrochemical measurements were recorded in 5 mM
2
[Fe(CN)6]3−/4− redox couple solution (1:1 molar ratio) in a 0.1 M PBS buffer.
3 4
Food samples analysis
5
Preparation of extracts
6
Four commercial samples obtained from local stores were used (mango juice, soya milk, tomato
7
and plum). For the solid fruit samples (tomato and plum), the samples were blended to obtain a
8
homogeneous mixture. One gram of each sample was mixed with 2 ml of CBZ extraction buffer
9
from the ELISA kit, 4 ml of acetonitrile and vortexed for 3 min. Then, the mixture was
10
centrifuged for 10 min at 4000 g. 1 ml of the supernatant was transferred to another tube and
11
dried by evaporating the solvent in 60 oC water bath. The dried residue is then dissolved in 1 ml
12
solution of either binding buffer for the aptasensor experiments or extraction buffer for the
13
ELISA experiments. For the liquid samples (juice and milk), the samples were centrifuged at
14
4000 g for 10 min., and the supernatant was filtered using 0.45 µm cellulose acetate centrifuge
15
filters. The prepared extracts were divided into small aliquots and stored at -20 °C until used.
16
Finally, the extracts were diluted 1:10 with extraction buffer for ELISA or binding buffer for the
17
aptasensor and spiked with two concentrations of CBZ to obtain 1 ng/ml and 10 ng/ml. The
18
spiked extracts were then tested on the aptasensors as described above for the standard solutions.
19
Competitive ELISA experiment for comparison study
20
The extracts were analyzed according to the protocol of the ELISA kit. Briefly, 50 µL of the
21
spiked extracts and the five standard solutions (negative, 0.5, 1.5, 6, 12 ng/mL) provided in the
22
ELISA kit were added into the CBZ-BSA coated wells. Then, 100 µl of the first antibody for
23
CBZ was added to the wells and incubated for 30 min. Then, the wells were washed and
11 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
incubated with 150 µl of second antibody-HRP conjugate for 30 min followed by washing the
2
wells and adding the TMB substrate. After 15 min, the reaction was stopped using stop buffer
3
solution and the absorbance of the ELISA plate was measured in plate reader at 450 nm wave
4
length. All the samples were done in duplicates.
Page 12 of 33
5 6
Results and discussion
7
Selection of DNA aptamers for CBZ
8
One of the most important steps for the aptamer selection is the immobilization of the small
9
target analyte on a solid support in order to enable the separation of the bound from the unbound
10
DNA during the selection. Because of the very small size of CBZ (191 g/mol), the lack of
11
chemical function groups and the need of sophisticated organic synthesis process to produce a
12
hapten for conjugation 32, we utilised a commercial ELISA plate on which CBZ-BSA conjugate
13
was already coated as a solid matrix. The progress of the SELEX was followed by assessing the
14
DNA recovery after each round by measuring the fluorescence intensity of the eluted DNA. As
15
shown in Fig. 1A, no fluorescence was detected from the first until the fifth round which
16
indicates that the concentration of the recovered DNA was very low. At round 6, the DNA
17
recovery started to increase. Since the BSA protein size is much larger than the CBZ molecule,
18
there is a high possibility that the DNA could bind to the BSA leading to selecting aptamers that
19
are not specific to CBZ. Therefore, in order to discriminate between the bound DNA to CBZ and
20
to the BSA, we used a specific elution step from round 8 to 10 to ensure the recovery of only the
21
CBZ specific sequences. In fact, using specific elution by affinity is recommended in all the
22
selection cycles. However, this method requires high concentration of ultra pure analyte which
23
increases the cost. Therefore, simple non specific elution using denaturation with urea and
12 ACS Paragon Plus Environment
Page 13 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
heating is usually performed in the first rounds until high recovery of DNA is observed. Then,
2
specific elution is used in the last few rounds to specifically recover the sequences which have
3
the capability to bind to the free CBZ in solution. After the specific elution, extensive clean-up to
4
remove the CBZ from the DNA was performed using ultrafilteration as the excess CBZ can
5
inhibit the PCR.
6
After cloning of the eluted DNA from round 10, we picked 20 clones for sequencing and 44
7
all sequences were identified. Using PRALINE
software, multiple sequence alignment was
8
performed in order to see the similarities in the obtained sequences. As shown in Fig. S1, highly
9
conserved consensus sequence motifs were observed, therefore, we divided the sequences into 6
10
groups. We chose a representative sequence from each group for the affinity testing to CBZ.
11
Fig. 1B shows that the six tested sequences (CZ1,CZ2,CZ12,CZ5,CZ6 and CZ13) exhibited high
12
affinity to CBZ compared with the initial DNA library (control). Fig. 2 shows the binding
13
affinity curves of the six tested sequences. Non linear regression fitting of the binding curves was
14
used to determine the Kds. As shown in Table 1, all the tested sequences exhibited kds in the low
15
nanomolar range (60-250 nM) which indicates high affinity of the selected aptamers for CBZ.
16
The aptamer sequences which showed the highest affinity to CBZ was CZ12 and CZ13.
17 18
Electrochemical aptasensor for CBZ
19
The two aptamers which showed the highest affinities to CBZ (CZ12 and CZ13) were
20
synthesized with thiol modification from the 5' terminals and then immobilized on the gold
21
electrodes via self assembly monolayer formation. Our goal was to test the possibility of utilizing
22
the selected aptamers on a label-free biosensor platform based on probing the change in the
23
electrochemical impedance spectra of [Fe(CN)6]4-/3- redox couple of the aptasensor upon binding.
13 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
First, to fabricate the aptasensor, the aptamers were immobilized on the gold electrode
2
surface via self assembly and the free gold surface was blocked with MCH. As shown in Fig. 3,
3
CV and EIS were used to characterize the stepwise modification of the aptasensor. Fig. 3A
4
shows the CV of the bare Au, aptamer-modified Au and after blocking with MCH measured in a
5
5 mM solution of [Fe(CN)6]4-/3- redox couple in PBS buffer, pH 7.4. As expected, the clean bare
6
gold electrode showed a reversible redox peaks with a peak to peak separation (∆E) of 80 mV.
7
However, after the aptamer self assembly, the ∆E increased and the anodic and cathodic peak
8
currents decreased. This change of the characteristics of the CV indicated the successful
9
attachment of the aptamer on the gold which lead to shielding of the gold surface with the
10
negatively charged DNA. This shielding effect has lead in turn to diminishing of the electron
11
transfer between the redox molecules and the electrode. Upon blocking the Au electrodes with
12
MCH, a further increase in the ∆E was seen which suggests a decrease in the electron transfer
13
rate of the redox couple likely due to covering some of the free pinholes on the surface with the
14
MCH. In fact, the blocking step with MCH in order to form a mixed monolayer with the
15
thiolated aptamers is a crucial step not only to minimize the non specific adsorption but also to
16
avoid the physical adsorption of the DNA on the surface and retain the conformation of the
17
aptamers on the surface
18
work at 1µM concentration.
34
Page 14 of 33
. Therefore, the MCH concentration was optimized in our previous
19
The fabrication of the aptasensor was also confirmed using EIS as shown in Fig. 3B. The
20
impedance spectra were represented as Nyquist plots which exhibit a semicircle in the high
21
frequency domain and a straight line in the low frequency domain. The semicircular part
22
represents the electron transfer and the capacitive behavior of the system and the linear part
23
corresponds to the diffusion process. A modified Randles circuit was used to fit all the
14 ACS Paragon Plus Environment
Page 15 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
impedance spectra (inset of Fig. 3B, fitting is shown in Fig. S2). This circuit consists of four
2
elements, charge-transfer resistance (Rct), constant phase element (CPE), solution resistance (Rs),
3
and Warburg impedance (Zw).
4
with a distinctive straight light which indicates the fast electron transfer kinetics of the clean gold
5
surface. However, after the incubation of the thiolated aptamer on the electrodes, a significanmt
6
increase in the diameter of the semi circle of the impedance spectra was observed. This increase
7
in diameter indicates the increase in the Rct due to the reulsion of the [Fe(CN)6]4-/3- anions with
8
the attached negatively charged DNA. Then the Rct was further increased upon incubation with
9
MCH. Thus, the EIS results were consistent with the CV results indicating the successful
10
45-46
The EIS of the bare Au electrode showed a small semi circle
fabrication of the aptasensors.
11
After characterizing the aptasensors, we then started to test the response of the aptasensor
12
to the binding with CBZ. Two aptasensors were individually prepared by immobilizing the
13
aptamers; CZ12 and CZ13 on two different electrodes and the response of the two sensors to the
14
binding with CBZ was assessed. As shown in Fig.S3, the response of the aptasensors, measured
15
as the change of the Rct upon binding with 100 ng/ml solution of CBZ, was significantly higher
16
in the case of CZ13. This result demonstrates that the aptamer CZ13 exhibits more change in the
17
conformation upon binding with CBZ than CZ12 despite of their comparable Kds. The change of
18
the aptamer conformation has lead to more shielding of the Au surface, less access for the
19
[Fe(CN)6]3−/4− redox molecules to surface and therefore, retardation of the electron transfer. The
20
change of the Rct due to the conformation change induced by the CBZ binding to aptasensor
21
CZ13 was used as the basis for the biosensor detection (scheme 1).
22
In order to determine the analytical range of the aptasensor, the impedance response of
23
the aptasensor after binding with different concentrations in the range of (10 pg/ml to 1 µg/ml) of
15 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 16 of 33
1
CBZ was monitored. As shown in Fig.4A the diameter of the semi circle of the impedance
2
spectra increases with increasing the CBZ concentration. The Rct values obtained from the
3
impedance spectra was used to build the calibration curve as it was the most changeable
4
parameter in the circuit. The aptasensor response was calculated as the percentage change in the
5
Rct after binding with certain concentration of CBZ ((Ro-R)/Ro%). Fig. 4B shows the calibration
6
curve of the aptasensor (a plot of the aptasensor response versus the logarithm of the CBZ
7
concentration). A linear relationship was observed from 10 pg/ml to 10 ng/ml (the linear
8
regression equation is: (Ro-R)/Ro %= 62.2+ 22.9 log C [ng/ml], R = 0.994. All the measurements
9
were done in triplicates and the error bars represent the standard deviations of the measurements
10
(RSD%= 3.0-5.4), demonstrating the high accuracy of the aptasensor. The limit of detection
11
(LOD) of the developed CBZ aptasensor was 8.2 pg/ml (LOD= 3Sb/m, where Sb is the standard
12
deviation of the blank signal and m is the slope of the linear part of the calibration curve). This
13
calculated detection limit indicates high sensitivity of the proposed aptasensor as it is lower than
14
the LOD of the available commercial ELISA kit by 2 order of magnitude, the reported
15
immunoassay 30, Raman scattering detection 14 as well as electrochemical assays 22,27,47-48 (Table
16
S2).
17
The cross reactivity of the developed CBZ aptasensor with 100 ng/ml solution of a
18
variety of potential related interfering agricultural compounds was tested in order to verify the
19
selectivity of the sensor. As show in Fig. 5, the aptasensor responses with all the examined non
20
specific pesticides (atrazine, linuron, thiamethoxam, trifluralin, carbaryl, methyl parathion,
21
fenamiphos and ioproturon) were not significant compared with the high response obtained with
22
CBZ. These results confirm the high selectivity of the developed aptasensor and its possible
16 ACS Paragon Plus Environment
Page 17 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
applicability for the selective quantification of CBZ without interference with other compounds
2
particularly other electroactive molecules such as fenamiphos and ioproturon
3
The developed aptasensor was then examined in different real food samples (soya milk,
4
mango juice, tomato and plum fruit). After extraction as explained in the experimental section
5
the samples were spiked with two different concentrations of CBZ (1.0 and 10 ng/ml). The
6
spiked extracts were then analysed using the proposed aptasensor and a commercial ELISA kit.
7
As shown in Table 2, the recovery percentages of the proposed aptasensor were between 89%
8
and 95% which were in good correlation with that obtained using standard ELISA. These results
9
reveal that there is no significant matrix effect on the aptasensor response signal, and thus, the
10
aptasensor can be applied for the detection of CBZ in complex real food samples for routine use.
11 12 13 14 15
Conclusion In this work, we presented the first selection and characterization of DNA aptamer sequences
16
against CBZ. The selected aptamers exhibited high affinity for CBZ with calculated dissociation
17
constants in the nanomolar range. One of the highest affinity aptamers (Kd=65 nM) was then
18
applied in a label-free biosensor using EIS. The detection mechanism was based on monitoring
19
the change in the charge transfer resistance of a [Fe(CN)6]3−/4− redox couple that is induced by
20
the alteration of the aptamer conformation upon binding with CBZ. The aptasensor showed fast
21
response (30 min) and high sensitivity (detection limit of 8.2 pg/ml). Moreover, the developed
22
aptasensor exhibited highly selectivity to CBZ and did not show any cross reactivity with other
23
pesticides such as atrazine, linuron, thiamethoxam, trifluralin, carbaryl and methyl parathion,
24
particularly electroactive compounds (fenamiphos and ioproturon). The aptasensor was also
25
applied for the detection of CBZ in spiked real food sample and high recovery percentages were
17 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
obtained which were in good agreement with the results obtained from a standard ELISA
2
method. This indicates great promise for using the developed aptasensor as alternative to the
3
current traditional assays.
4 5 6
ACKNOWLEDGMENTS
7
The authors would like to thank the food safety laboratory in Al-Qassim, KSA for providing the
8
standard pesticide solutions.
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38
References
18 ACS Paragon Plus Environment
Page 18 of 33
Page 19 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
(1) Hernandez, P.; Ballesteros, Y.; Galan, F.; Hernandez, L. Electroanalysis 1996, 8, 941-946.
2
(2) Lim, J.; Miller, M. G. Toxicol. Appl. Pharmacol. 1997, 142, 401-410.
3
(3) Farag, A.; Ebrahim, H.; ElMazoudy, R.; Kadous, E. Birth Defects Res. B Dev. Reprod.
4
Toxicol. 2011, 92, 122-130.
5
(4) Knacker, T.; van Gestel, C. A. M.; Jones, S. E.; Soares, A. M. V. M.; Schallnaß, H.-J.;
6
Förster, B.; Edwards, C. A. Ecotoxicology 2004, 13, 9-27.
7
(5) Prashantkumar, W.; Sethi, R. S.; Pathak, D.; Rampal, S.; Saini, S. P. S. Toxicol. Environ.
8
Chem. 2012, 94, 1433-1442.
9
(6) Goldman, J. M.; Rehnberg, G. L.; Cooper, R. L.; Gray, L. E.; Hein, J. F.; McElroy, W. K.
10
Toxicology 1989, 57, 173-182.
11
(7) Sánchez-Rasero, F.; Romero, T. E.; Dios, C. G. J. Chromat. A 1991, 538, 480-483.
12
(8) Bilehal, D. C.; Chetti, M. B.; Sung, D. D.; Goroji, P. T. J. Liq. Chromatogr. Relat. Technol.
13
2014, 37, 1633-1643.
14
(9) Subhani, Q.; Huang, Z.; Zhu, Z.; Zhu, Y. Talanta 2013, 116, 127-132.
15
(10) Grujic, S.; Radisic, M.; Vasiljevic, T.; Lausevic, M. Food Addit. Contam. 2005, 22, 1132-
16
1137.
17
(11) Belmonte Vega, A.; Garrido Frenich, A.; Martínez Vidal, J. L. Anal. Chim. Acta 2005, 538,
18
117-127.
19
(12) Takeda, S.; Fukushi, K.; Chayama, K.; Nakayama, Y.; Tanaka, Y.; Wakida, S.-i. J.
20
Chromatogr. A 2004, 1051, 297-301.
21
(13) Kaltsonoudis, C. K.; Lamari, F. N.; Prousalis, K. P.; Karamanos, N. K.; Tsegenidis, T.
22
Chromatographia 2003, 57, 181-184.
23
(14) Strickland, A. D.; Batt, C. A. Anal. Chem. 2009, 81, 2895-2903.
19 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 20 of 33
1
(15) Furini, L. N.; Sanchez-Cortes, S.; López-Tocón, I.; Otero, J. C.; Aroca, R. F.; Constantino,
2
C. J. L. J. Raman Spectrosc. 2015, 46, 1095-1101.
3
(16) Garrido Frenich, A.; Picón Zamora, D.; Martı́nez Vidal, J. L.; Martı́nez Galera, M. Anal.
4
Chim. Acta 2003, 477, 211-222.
5
(17) Martı́nez Galera, M.; Picón Zamora, D.; Martı́nez Vidal, J. L.; Garrido Frenich, A.;
6
Espinosa-Mansilla, A.; Muñoz de la Peña, A.; Salinas López, F. Talanta 2003, 59, 1107-1116.
7
(18) Lezcano, M.; Al-Soufi, W.; Novo, M.; Rodríguez-Núñez, E.; Tato, J. V. J. Agric. Food
8
Chem. 2002, 50, 108-112.
9
(19) Moral, A.; Sicilia, M. D.; Rubio, S.; Pérez-Bendito, D. Anal. Chim. Acta 2008, 608, 61-72.
10
(20) Pourreza, N.; Rastegarzadeh, S.; Larki, A. Talanta 2015, 134, 24-29.
11
(21) Liao, S.; Xie, Z. Spectrosc. Lett. 2006, 39, 473-485.
12
(22) Cui, R.; Xu, D.; Xie, X.; Yi, Y.; Quan, Y.; Zhou, M.; Gong, J.; Han, Z.; Zhang, G. Food
13
Chem.
14
(23) França, R. F.; de Oliveira, H. P. M.; Pedrosa, V. A.; Codognoto, L. Diamond Relat. Mater.
15
2012, 27–28, 54-59.
16
(24) Luo, S.; Wu, Y.; Gou, H. Ionics 2013, 19, 673-680.
17
(25) Manisankar, P.; Vedhi, C.; Selvanathan, G. Trans. SAEST 2002, 37, 135-140.
18
(26) Li, J.; Chi, Y. Pestic Biochem Physiol. 2009, 93, 101-104.
19
(27) Guo, Y.; Guo, S.; Li, J.; Wang, E.; Dong, S. Talanta 2011, 84, 60-64.
20
(28) Noyrod, P.; Chailapakul, O.; Wonsawat, W.; Chuanuwatanakul, S. J. Electroanal. Chem.
21
2014, 719, 54-59.
22
(29) Lima, T.; Silva, H. T. D.; Labuto, G.; Simões, F. R.; Codognoto, L. Electroanalysis 2016,
23
28, 817-822.
20 ACS Paragon Plus Environment
Page 21 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
(30) Itak, J. A.; Selisker, M. Y.; Jourdan, S. W.; Fleeker, J. R.; Herzog, D. P. J. Agric. Food
2
Chem. 1993, 41, 2329-2332.
3
(31) Zikos, C.; Evangelou, A.; Karachaliou, C.-E.; Gourma, G.; Blouchos, P.; Moschopoulou,
4
G.; Yialouris, C.; Griffiths, J.; Johnson, G.; Petrou, P.; Kakabakos, S.; Kintzios, S.; Livaniou, E.
5
Chemosphere 2015, 119, Supplement, S16-S20.
6
(32) Yan, H.; Liu, L.; Xu, N.; Kuang, H.; Xu, C. Food Agric. Immunol. 2015, 26, 659-670.
7
(33) Ruscito, A.; DeRosa, M. C. Front. Chem. 2016, 4, 14.
8
(34) Eissa, S.; Ng, A.; Siaj, M.; Tavares, A. C.; Zourob, M. Anal. Chem. 2013, 85, 11794-11801.
9
(35) Eissa, S.; Ng, A.; Siaj, M.; Zourob, M. Anal.Chem. 2014, 86, 7551-7557.
10
(36) Eissa, S.; Siaj, M.; Zourob, M. Biosens. Bioelectron. 2015, 69, 148-154.
11
(37) Contreras Jiménez, G.; Eissa, S.; Ng, A.; Alhadrami, H.; Zourob, M.; Siaj, M. Anal.
12
Chem.2015, 87, 1075-1082.
13
(38) Akki, S. U.; Werth, C. J.; Silverman, S. K. Environ. Sci. Technol. 2015, 49, 9905-9913.
14
(39) Nikolaus, N.; Strehlitz, B. Sensors (Basel, Switzerland) 2014, 14, 3737-3755.
15
(40) Wang, S.; Yong, W.; Liu, J.; Zhang, L.; Chen, Q.; Dong, Y. Biosens. Bioelectron. 2014, 57,
16
192-198.
17
(41) Bai, W.; Zhu, C.; Liu, J.; Yan, M.; Yang, S.; Chen, A. Environ. Toxicol. Chem. 2015, 34,
18
2244-2249.
19
(42) Wang, L.; Liu, X.; Zhang, Q.; Zhang, C.; Liu, Y.; Tu, K.; Tu, J. Biotechnol Lett. 2012, 34,
20
869-874.
21
(43) Zhang, C.; Wang, L.; Tu, Z.; Sun, X.; He, Q.; Lei, Z.; Xu, C.; Liu, Y.; Zhang, X.; Yang, J.;
22
Liu, X.; Xu, Y. Biosens. Bioelectron.2014, 55, 216-219.
23
(44) Simossis, V. A.; Kleinjung, J.; Heringa, J. Nucleic Acids Res. 2005, 33, 816-824.
21 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
(45) Randles. J. Discuss. Faraday Soc. 1947, 1, 11–20.
2
(46)
3
2nd ed., Wiley & Sons, New York, 2001.
4
(47) Maximiano, E. M.; de Lima, F.; Cardoso, C. A. L.; Arruda, G. J. J. Appl. Electrochem
5
2016, 46, 713-723.
6
(48) Ya, Y.; Wang, T.; Xie, L.; Zhu, J.; Tang, L.; Ning, D.; Yan, F. Anal.Meth. 2015, 7, 1493-
7
1498.
Page 22 of 33
Bard, A. J.; Faulkner, L. R. Electrochemical Methods: Fundamentals and Applications,
8 9
10 11 12 13
14 15 16 17 18 19 20 21
Figure captions:
22
Fig. 1 (A) The recovery profile of the eluted DNA during the SELEX cycles (a plot of the
23
fluorescence intensity versus the round number) (B) Fluorescence binding assays of the selected
22 ACS Paragon Plus Environment
Page 23 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1
aptamers and the DNA library as a control. The error bars represent the standard deviations of
2
the measurements.
3
Fig. 2 Binding affinity curves obtained using fluorescence assays of CBZ with the aptamers and
4
CZ13 (A), CZ2 (B), CZ5 (C), CZ6 (D), CZ1 (E) and CZ12 (F). The Dissociation constants were
5
calculated by non linear regressing fitting of the curves. The error bars represent the standard
6
deviations of the measurements.
7
Fig. 3 CV (A) and EIS Nyquist plots (B) of 5 mM [Fe(CN)6]4−/3− redox solution in PBS buffer,
8
pH 7.4, for bare the Au electrode (black line), aptamer/Au (red line) and MCH/aptamer/Au (blue
9
line). The CV was done at scan rate of 100 mV/s and the EIS was recorded using a frequency
10
range of 104 to 0.1 Hz, a DC potential of +0.20 V and AC amplitude of 5 mV. The inset in Fig.
11
3B is the modified Randles equivalent circuit used to fit the impedance spectra.
12
Fig. 4 (A) Nyquist plots of the CBZ aptasensor after incubation with different concentrations of
13
CBZ 0.00, 0.01, 0.1, 1.0, 10 and 100 ng/ml. (B) The calibration curve for CBZ (plot of (Ro-
14
R)/Ro% vs. logarithm of the CBZ concentration. The measurements were done in triplicates and
15
the error bars represent the standard deviations of the measurements.
16
Fig.5 Comparison of the aptasensor response to 100 ng/ml solution of CBZ, atrazine, linuron,
17
thiamethoxam, trifluralin, carbaryl, methyl parathion, fenamiphos and ioproturon.
18
19 20
Scheme 1. The detection mechanism of the CBZ aptasensor based target-induced conformation
21
change of the aptamer.
22
23 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1 2
Table 1. Sequences and dissociation constants (Kd) of CBZ and selected aptamers.
3
Table 2. Real food samples testing using the developed CBZ aptasensor and commercial ELISA.
Page 24 of 33
4
5
6
7
8
9
10
11
12
13
14
15
16
17
Table. 1
18
Aptamer
Aptamer sequence 24 ACS Paragon Plus Environment
Kd
Page 25 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
number
(nM)
CZ1
GGTCGCAGCAGCCTGTACACCCACCCACCAGCCCCAGCATCATACCCATTC GTGCCGTG
91
CZ2
GGCGACACAGCAACACACCCACCCACCTGCCCCATCAACAACCTATCCCTG TCCGTGCG
72
CZ12 CZ5
CGACACAGCGGAGGCCACCCGCCCACCAGCCCCTGCAGCTCCTGTACCTGT GTGTGTG GGCCATCGGACCACAGTACCCACCCACCGGCCCCAACATCATGCCCTCGTT GTTGTGTG
60.2 250
CZ6
CGACACGCAGCATACGTACGCCGCCCTATAGCGTAGCCCTCCCACCACCCC CGCATCG
73
CZ13
GGGCACACAACAACCGATGGTCCAGCCACCCGAATGACCAGCCCACCCGC CACCCCGCG
65
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Table 2
Aptasensor
ELISA
25 ACS Paragon Plus Environment
Analytical Chemistry
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Spiked concentration (ng/ml)
Amount found (ng/ml)
Recovery %
Soya milk
1.0
0.86
10
Mango Juice
Sample
Tomato
Plum 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Page 26 of 33
RSD%
Amount found (ng/ml)
Recovery %
RSD%
86
4.2
0.85
85
7.0
8.9
89
5.1
10.5
105
7.2
1.0
0.92
92.0
5.0
0.9
90
7.6
10
9.3
93.0
4.3
8.0
80
7.3
1.0
0.93
93.0
3.5
0.84
84
6.5
10
9.1
91
3.8
10.5
105
6.8
1.0
0.94
94
3.1
0.9
90
7.5
10
9.5
95
4.0
10.3
103
7.8
Scheme 1.
26 ACS Paragon Plus Environment
Page 27 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Analytical Chemistry
Fig. 1 27 ACS Paragon Plus Environment
Analytical Chemistry
16 16
A
14
14
Fluorescence intensity
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40
Fluorscence Intensity
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 28 of 33
12 10 8 6 4
12 10 8 6 4 2
2 0
B
0 1
2
3
4
5
6
7
8
9
10
CZ13
Selection round
CZ6
Fig. 2 28 ACS Paragon Plus Environment
CZ1
CZ2
CZ5
CZ12 library
Page 29 of 33
1 2 3 20 4 A 5 15 6 7 Kd= 65 nM 10 8 9 5 CZ13 10 11 0 12 0 100 200 300 13 DNA conc. (nM) 15 14 D 15 16 10 17 Kd= 73 nM 18 195 CZ6 20 21 0 22 0 100 200 300 23 DNA conc. (nM) 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 Fig. 3
Fluorescence Intensity Fluoresce nce Intensity
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
15
15
B
C
10
10
Kd= 72 nM 5
Kd= 250 nM 5
CZ2 0 400 0
100
CZ5
200
300
0 400 0
100
DNA conc. (nM) 20
400
F
15
15
Kd= 91 nM
10 5 0 400 0
300
DNA conc. (nM)
20
E
200
5
CZ1 100
200
Kd= 60 nM
10
300
DNA conc. (nM)
29 ACS Paragon Plus Environment
0 400 0
CZ12 100
200
DNA conc. (nM)
300
400
Analytical Chemistry
1 2 3 4 5 6
80
2100
A
40
7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38
Bare Au Apamer/Au MCH/Aptamer/Au
1500
20
1200
0 -20
900 600
-40
300
-60 -0.2
B
1800 Bare Au Apamer/Au MCH/Aptamer/Au
-Z im (Ω )
60
Current (µA)
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Page 30 of 33
0
0.0
0.2
0.4
0.6
0
1000
E (V) vs Ag-AgCl
2000
3000
Zr (Ω)
Fig. 4 30 ACS Paragon Plus Environment
4000
5000
Page 31 of 33
1 2
100 MCH/Aptamer/Au 0.01 ng/ml CBZ 0.1 ng/ml CBZ 1.0 ng/ml CBZ 10 ng/ml CBZ 100 ng/ml CBZ
2800
A
2400 2000
90 80 (R-Ro)/Ro %
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39
-Zim (Ω )
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
Analytical Chemistry
1600 1200
B
70 60 50 40
800
30
400
20
0
10
0
1000 2000 3000 4000 5000 6000 7000
0.01
0.1
1
10
100
Log CBZ concentration (ng/ml)
Zr (Ω)
Fig. 5 31 ACS Paragon Plus Environment
1000
Analytical Chemistry
1
80
(R-Ro)/Ro %
60
40
20
et hy l
C pa BZ r th ia athi m on et ho xa ca m rb ar yl tri flu ra lin lin ur on At Fe raz na ine m ip Is h op os ro tu ro n
0
m
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
2
32 ACS Paragon Plus Environment
Page 32 of 33
Page 33 of 33
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60
1
Analytical Chemistry
TOC
2
3 4
5
6
7
8
9 33 ACS Paragon Plus Environment