Single-Walled Carbon Nanotube Back-to-Back Schottky

Dec 11, 2013 - Palladium/Single-Walled Carbon Nanotube Back-to-Back Schottky. Contact-Based Hydrogen Sensors and Their Sensing Mechanism...
0 downloads 0 Views 1MB Size
Research Article www.acsami.org

Palladium/Single-Walled Carbon Nanotube Back-to-Back Schottky Contact-Based Hydrogen Sensors and Their Sensing Mechanism Miluo Zhang,† Lauren L. Brooks,† Nicha Chartuprayoon,† Wayne Bosze,† Yong-ho Choa,‡ and Nosang V. Myung*,† †

Department of Chemical and Environmental Engineering and Center for Nanoscale Science and Engineering, University of CaliforniaRiverside, Riverside, California 92521, United States ‡ Department of Fine Chemical Engineering/Bionano Technology, Hanyang University, Ansan 426-791, Korea ABSTRACT: A Schottky contact-based hydrogen (H2) gas sensor operable at room temperature was constructed by assembling single-walled carbon nanotubes (SWNTs) on a Si/ SiO2 substrate bridged by Pd microelectrodes in a chemiresistive/chemical field effect transistor (chemFET) configuration. The Schottky barrier (SB) is formed by exposing the Pd−SWNT interfacial contacts to H2 gas, the analyte it was designed to detect. Because a Schottky barrier height (SBH) acts as an exponential bottleneck to current flow, the electrical response of the sensor can be particularly sensitive to small changes in SBH, yielding an enhanced response to H2 gas. The sensing mechanism was analyzed by I−V and FET properties before and during H2 exposure. I−Vsd characteristics clearly displayed an equivalent back-to-back Schottky diode configuration and demonstrated the formation of a SB during H2 exposure. The I−Vg characteristics revealed a decrease in the carrier mobility without a change in carrier concentration; thus, it corroborates that modulation of a SB via H2 adsorption at the Pd−SWNT interface is the main sensing mechanism. KEYWORDS: Schottky contact, hydrogen (H2) gas sensor, Pd, single-walled carbon nanotubes (SWNTs), response time

1. INTRODUCTION

a H2-induced lattice expansion show improved sensor response times but albeit at the expense of low sensitivity.8 Schottky contact-based H2 sensors focus on the contact area between the Pd electrode and the semiconductor, where the modulation of contact barrier height is the key factor in determining the performance of a sensor. A metal−semiconductor interface can possess rectifying or nonrectifying energy levels, namely, Schottky or ohmic contacts, respectively. In an ohmic contact, resistance is inversely proportional to the cross sectional area perpendicular to the current and the charge carriers can flow in either direction without rectification under an applied potential. In an ohmic contact-based sensor, the interface resistivity is made as low and as stable as possible to place emphasis on the signal contribution coming from the semiconductor itself. For a rectifying SB contact-based sensor, the opposite effects are required. Because a SBH acts as an exponential limit to current flow in accordance with the law of thermionic emission,12 the aim of making the modulation of SBH, the key factor in performance, can be achieved by making the SBH a dynamic, sensitive and reversible function of the target analyte concentration. An exponential dependence on a key factor naturally overrides a linear dependency, yielding an enhanced sensitivity sensor. This corroborates the fact that

Hydrogen (H2) is a potentially emission-free alternative fuel that is considered to be an ideal energy carrier in the foreseeable future. Rapid and accurate H2 sensors with a low detection limit have been of significant interest and in high demand for safety concerns due to hydrogen’s low spark ignition energy (0.017 mJ) and wide flammable range (4− 75%).1 Several types of H2 sensors2 have been developed based on metal oxides such as In2O3,3 SnO2,4 ZnO,5 NiO,6 and TiO2.7 However, each selective gas response requires a wellcontrolled specific high temperature (a few hundred °C) to achieve optimal sensitivity. While elevating the temperature of the sensor accelerates the transport of gases, thus improving both response and recovery times, it can also increase power consumption and device complexity. Palladium (Pd) has been found to be an excellent sensing material for H2 due to its catalytic properties and high solubility toward H2 under ambient conditions. It has been reported that the reversible formation of palladium hydride (PdHx) is the determining factor for Pd-based sensors, where any number of effects could be exploited, including modulating its lattice constant,8 conductivity,9 work function,10 or optical properties.11 Pd sensors that take advantage of H 2-induced modulation in resistance show good sensitivity but suffer from delayed response and recovery times due to slow gas transport processes. Pd nanocluster-based H2 sensors exploiting © 2013 American Chemical Society

Received: October 2, 2013 Accepted: December 11, 2013 Published: December 11, 2013 319

dx.doi.org/10.1021/am404328g | ACS Appl. Mater. Interfaces 2014, 6, 319−326

ACS Applied Materials & Interfaces

Research Article

Figure 1. (a) Real-time sensing response, (b) calibration curve, (c) response time, and (d) recovery time of AC aligned SWNTs on Pd microelectrodes toward H2 at different concentrations. The sensing performance including sensitivity, response time, and recovery time are characterized based on a sample number of 14.

Schottky contact-base sensors have been found to show higher sensitivities to analyte gases than ohmic contact-based sensors. In accordance with the Schottky−Mott model, there is a linear dependence between the SBH and the metal work function. Thus, modulation in the metal work function leads to a direct modulation in the SBH in the metal−semiconductor junction, causing an exponential change in the conductance of the sensor. Over the past few decades, Schottky contact-based H2 sensors have been fabricated by the utilization of Pd with various semiconductors, such as Si,13 TiO2,14 and SnO2.15 Although a vast improvement in sensitivity and low detection limits have been achieved within these configurations, the SBH on most semiconductors are found to have a much weaker dependence on the metal work function than the Schottky− Mott model suggests. This phenomenon, known as Fermi level pinning, where interface states tend to pin the center of the band gap to the Fermi level, along with undesired compound formation,13 reduces the expected SBH and thus diminishing the sensor performance. Carbon nanotubes (CNTs) have been of significant interest owing to their unique electrical, physical, mechanical, and chemical properties, leading to a wide array of applications, including supercapacitors, electrodes, field emission devices, sensors, and other nanoelectronic devices.16 By taking advantage of its quasi-one-dimensional (1-D) transport properties, CNTs have been widely used as chemiresistive/ ChemFETs gas sensors, offering the potential to outperform the established two-dimensional (2-D) thick- and thin-film sensors.10 In particular, weak Fermi level pinning is anticipated in a metal−CNT contact because the pinning charge has to compete with the large charge density at the van Hove singularities in the density of states of CNTs.17 In other words, the SBH should be completely controlled by the metal work function in a metal−CNT contact (i.e., display Schottky−Mott model behavior). This is in strong contrast to most bulk metal−semiconductor junctions where Fermi level pinning often dominates the SBH.17

In this work, we study the effects of p-type SWNTs in contact with Pd electrodes and show that the development of SBs at the contacts under H2 exposure enhances their sensing performances. The sensing mechanism was confirmed by I−V and FET properties characterization before and during H2 exposure. Even though the modulation of the SBH by H2 has already been reported for a Pd−CNT contact,10 a H2 sensor based on this configuration with high sensitivity and fast response/recovery time has not been demonstrated. The Pd− SWNTs sensor showed an enhanced sensing performance when contrasted with other aligned SWNTs made with Pt, Cr, and Au microelectrodes.

2. EXPERIMENTAL SECTION Detailed information on these sensor configurations have been described in our recently published paper.18 Briefly, various metal microelectrodes including Pd, Pt, Cr, and Au patterned on oxidized Si substrates (with a SiO2 thickness of 300 nm) were fabricated via lift-off photolithography processes. Prior to use, prefabricated microelectrode chips were sonicated in nanopure water, followed by an acetone rinse to remove residues. The CNT suspension was prepared by adding 0.2 mg of commercially available carboxylated SWNTs (Carbon Solution, Inc. Riverside, CA) in 20 mL of N,N-dimethylformamide (DMF, Sigma Aldrich, MO) and sonicating the mixture solution for 90 min until a well-dispersed solution was obtained. The supernatant of the suspended SWNTs solution was collected after centrifuging at 15,000 rpm for 90 min. To accurately align SWNTs across a prefabricated microelectrode, a customized Teflon cell was employed to hold the microelectrode chip and confine the suspended SWNTs solution for the AC dielectrophoretic alignment. The electrical connection between the external electronic equipment and the microelectrode chip was obtained by clipping the chip with two 32 pin SOIC test clips purchased from Pomona Electronics. Afterwards, 200 μL of the supernatant was placed into the Teflon cell with the chip held for SWNT alignment. To obtain optimized SWNT alignment, a 2 peak to peak voltage (Vpp) at 4 MHz frequency was applied to the electrodes for an average of 10 s. A Labview program was designed to command the Keithley 3390 AC generator (aligner) and custom-made DAQ switcher for sequential SWNT alignment. The synthesized sensors were rinsed with nanopure 320

dx.doi.org/10.1021/am404328g | ACS Appl. Mater. Interfaces 2014, 6, 319−326

ACS Applied Materials & Interfaces

Research Article

Figure 2. (a−c) Real-time sensing response and (d) calibration curves of AC aligned SWNTs on (a) Pt, (b) Cr, and (c) Au electrodes toward H2 at different concentration. water, dried with ultra-pure N2 gas, and then annealed at 300 °C for 2 h in forming gas. Back-gated FET properties (I−Vg characteristics) were measured by sweeping the gate voltage from −20 V to +20 V with a fixed sourcedrain voltage of 1 V during exposures of dry air and 2000 ppmv H2 gas in dry air, respectively. Furthermore, the sensing performance was investigated by assembling the sensing chip in a sealed Teflon sensing cell with gas inlet and outlet ports for gas flow and then clipping the chip to a Keithley 236 source measurement to obtain the electrical connection. An applied potential of 1 V was given to each sensor and the resistance was continuously monitored every 0.2 s for the 15 sensors by a custom-made LabView program. H2 gas was first diluted in dry air to various concentrations and then introduced into the Teflon cell at a total gas flow of 200 sccm for gas sensing measurements.

90% of its steady-state value and the time required for the sensor to return to 10% of its maximum response. However, the recovery time τ50, which indicates the time needed for the sensor response to restore 50% of its maximum response, is chosen for sensor performance evaluation owing to slow recovery rates against rapid cycling of H2 concentration. Figure 1c,d illustrated the sensor response time τ90 and recovery time τ50 at room temperature as a function of H2 concentration. The average response time for the Pd−SWNTs sensor was determined to be 10 min at H2 concentration of 50 ppmv. The response time decreased rapidly to 1.13 min at H2 concentration of 2000 ppmv. A trend line of average response time τ90 as a logarithmic function of H2 concentration for the Pd-sensor gives τ90 = −2.43 × Ln ([H2]) + 19.47 with a R2 = 0.9989. Extrapolating to 25 ppmv of H2 gas gives an average response time τ90 = 11.8 minutes. The average recovery time τ50 was also reduced from 12.28 min at 50 ppmv to 0.37 min at 2000 ppmv of H2. Complete recovery was observed after the final H2 exposure with recovery time τ100 of 30 min at 2000 ppmv. The sensing performance (ΔR/R0 × 100)% of Pd−SWNTs aligned sensor to H2 gas exposure is contrasted with other aligned SWNTs made with Pt, Cr, and Au microelectrodes in Figure 2a−c, respectively. The response of the Pt−SWNTs aligned sensor shown in Figure 2a is mainly attributed to the catalytic properties of Pt toward H2 adsorption. The adsorbed hydrogen atoms exothermically react with oxygen molecules or weakly adsorbed oxygen atoms on the Pt surface, leading to hydroxyl radicals and/or water formation. The local heating from this catalytic reaction is considered to be a major contributor to the sensing response. However, this exothermic reaction was not activated until H2 concentration exceeded 250 ppmv, and a very pronounced response (i.e., ΔR/R0 = 8.98%) was obtained at 2000 ppmv of H2 gas. The drawback to the Pt− SWNT aligned sensor is its slow response and recovery time due to the slow gas adsorption processes at room temperature. Even though the Cr−SWNT aligned sensor gave about the same response (ΔR/R0 ≈ 2.5%) at 250 ppmv of H2 gas as the Pt−SWNT aligned sensor, the Cr-sensor’s signal was more

3. RESULTS AND DISCUSSION The sensing performance to H2 adsorption on the aligned SWNTs bridged across the Pd microelectrodes configured as chemiresistors was investigated at room temperature. These sensors were sequentially tested with varied concentrations of H2 gas ranging from 50 to 2000 ppmv with a period of H2 exposure for 15 min and a period with dried air for 20 minutes, respectively. The transient response was plotted as the normalized change in electrical resistance [ΔR/R0 × 100 = (Rf − R0)/R0 × 100] % of sensors as shown in Figure 1a, where Rf is the peak resistance and R0 is the initial baseline resistance prior to analyte exposure. The ΔR/R0 increased to a steadystate during H2 exposure and returned to its initial baseline when switching H2 back to dried air. Figure 1b presents the plot of ΔR/R0 as a function of H2 concentration showing a logarithmic function relationship. The inset in Figure 1b depicts the plot of ΔR/R0 as a function of H2 concentration on a semilog scale, yielding a rather straight line given by ΔR/R0 (%) = 3.440 × Ln ([H2]) − 8.584 with a correlation coefficient R2 = 0.9987. This relationship projects ΔR/R0 (%) ≈ 2.5% at 25 ppmv exposure. Additionally, the response and recovery times are important key factors when evaluating the overall sensing performance. In general, the response time τ90 and the recovery time τ90 are calculated, which are defined as the time for the sensor to reach 321

dx.doi.org/10.1021/am404328g | ACS Appl. Mater. Interfaces 2014, 6, 319−326

ACS Applied Materials & Interfaces

Research Article

Figure 3. (a) Response time and (b) recovery time of AC aligned SWNTs on Pd, Pt, and Cr electrodes towards 2000 ppmv H2. No recovery time for Cr electrodes is included.

Figure 4. (a) Current (IDS) − voltage (VDS) and (b) IDS − VDS1/4 characterization of AC aligned SWNTs on Pd electrodes in air (black) and 2000 ppmv H2 (red).

Figure 5. (a) Schematic representation (b) band diagram, and (c) equivalent circuit of SWNT devices in air (1) and H2 (2).

of Cr, therefore, decreasing its work function.19 This leads to an augment in the SBH at the Cr−SWNT interface, resulting in the resistance to increase. In our work, Schottky becoming “Schottkier” is considered to be the key factor to generate a distinct positive sensor response, because the native oxide layer on the surface of the Cr electrode is normally too thin to produce any well-defined negative response. Note, however, that the Cr-sensor exhibited no recovery after exposed to 250 ppmv of H2 gas and showed two distinguishable recovery rates in the higher H2 concentration region. The plateaued ΔR/R0 region indicates that an irreversible process happened on the

distinct (less noisy). The Cr sensor also gave a larger response than the Pt sensor at 2000 ppmv of H2 gas, with ΔR/R0 = 14.54% vs 9%, respectively. The sensor response of this device is expected to be controlled by the trade-off between the resistance decrease induced by the reduction of the native oxide layer and the resistance increase from the CrHx formation. Once the sensor is exposed under H2 gas, reduction of the native oxide layer on the surface of the Cr electrode will release the oxygen bonded electrons, increasing the electron concentration and decreasing the resistance. On the other hand, H2 is anticipated to cause an increase in the Fermi energy 322

dx.doi.org/10.1021/am404328g | ACS Appl. Mater. Interfaces 2014, 6, 319−326

ACS Applied Materials & Interfaces

Research Article

being the energy of the Fermi level of the semiconductor measured from the bottom of the conduction band. From these equations, the logarithm of the reverse thermionic current must be linear to the 4th root of bias voltage, as shown in the Figure 4b. Hence, the reverse thermionic emission current gives a satisfactory explanation of the experimental results. However, the SBH is not able to be extracted from a single I−V measurement because neither the effective Richardson’s constant nor the electrically active area of SWNT is known.17 FET characterization was carried out to confirm the SB based sensing mechanism in the Pd−SWNT system. Typical FET Ids − Vg curves in dry air and H2 gas are shown in Figure 6.

surface of the Cr electrode, such as a hydrogenation. Due to the much lower solubility of hydrogen in Cr than Pd, poorer performance was observed in the Cr−SWNT aligned device than Pd−SWNT. The Au−SWNT aligned sensor showed an insignificant response at all tested H2 concentrations. Figure 2d shows the (ΔR/R0 × 100)% response calibration curve of the four (i.e., Pd, Pt, Cr, Au) SWNT aligned chemiresistive H2 sensors, and the corresponding response/ recovery times plotted, as histograms referenced at 2000 ppmv of H2 gas, are shown in Figure 3. The response time of the Pd sensor was 8 times faster than the Pt sensor and about 11 times faster than the Cr sensor, whereas the recovery time of the Pd sensor was 46 times faster than the Pt sensor and the Cr sensor never did recover. This substantiated that aligned SWNTs bridged Pd microelectrodes had high affinity toward H2 gas and outperformed other fabricated sensors in this study. To confirm that the superior sensing performance from the Pd−SWNT was primarily from the SB modulation at the metal−semiconductor interface, electrical characterizations of the sensors were performed. Room temperature I−V sd characteristics show a linear response for SWNTs in air and a nonlinear, S-shaped I−V curve when the sensor was exposed to 2000 ppmv of H2 gas (Figure 4a). An ohmic contact was anticipated at the Pd interface and SWNT due to the larger work function of Pd (5.22 eV20) than that of SWNT (5.05 eV21). This assumption was corroborated by the experimentally obtained linear I−V characteristic in air. During H2 adsorption, atomic hydrogen is believed to dissolve into the Pd. Formation of Pd−H rapidly lowers the electronic work function (i.e., ∼0.4 eV) and creates a SB at the interfacial Pd−SWNT contact.22 Figure 5 shows the schematic diagrams of the sensor device and the band diagrams of Pd−SWNT−Pd contacts, demonstrating an equivalent back-to-back Schottky circuit. Among those back-to-back Schottky configurations where the thermionic emission rule applies, three models were frequently observed with regard to the number of MS interfaces considered as well as the direction of the current flow. Some papers (Model 1) treated back-to-back Schottky as a Schottky diode where only one forward current is counted to calculate the total current whereas other papers (Model 2) considered the total current is a sum of two forward biased currents. In this paper12 (Model 3), the total current is considered to be limited only by the reverse biased junction because this is the true bottleneck of the current. The reverse current can be explained by the following equations: ⎛ −qφb ⎞ ⎟ Ir = Is = AA*T 2exp⎜ ⎝ kT ⎠

Figure 6. Current (ISD) − back gated voltage (VG) characterization of AC aligned SWNT on Pd electrodes in air (black triangle) and 2000 ppm H2 (red square).

Notably, a decrease in source-drain current after exposure to H2 gas was observed irrespective of the gate voltages. This is consistent with the anticipated decrease in p-channel conductance due to the SB formation at Pd−SWNTs interface upon exposure to H2. If the charge transfer and chemical doping of the transducer is modulated by the gas molecules, an ion gating effect is anticipated as a sensing mechanism, resulting in a change in device carrier concentration with no change in its mobility.23 In contrast, if an electrostatic gating effect becomes the dominating sensing mechanism, the charge transfer between a sensitive element and gas analyte or chemical doping caused by gas molecules would alter the sensor’s carrier concentration. Therefore, a redistribution of the charge carriers therefore reflects a shift in Vth, while transconductance (i.e., carrier mobility) remains unchanged. The carrier mobility was calculated using the following equations:24

(1)

with φb = φ0 −

qE 4πεε0

μ=

and E=

2qND ⎛ kT ⎞ ⎜V0 + Vbi − ⎟ εε0 ⎝ q ⎠

( )

LSDWSD

(2)

dI dVG

CGVSD

(Eq. 4)

with (3)

CG =

where Ir is the total current equal to the saturation current, A* = 4πm*k2/h3 is the effective Richardson constant, A is the cross section of the effective area perpendicular to the current, φb is the effective barrier height, φ0 is the ideal barrier height, V0 is the bias voltage, and Vbi = ϕb − ξ is the built-in potential, with ξ

εδ(LSD)(WSD) t DL

(Eq. 5)

where μ is the carrier mobility (cm /(Vs)), LSD is the length of the SWNT or the electrodes’ gap size (3 μm), WSD is the width of the CNT film (10 μm), dI/dVG is the transconductance (A/ V), CG is the capacitance (F), VSD is the applied source-drain 2

323

dx.doi.org/10.1021/am404328g | ACS Appl. Mater. Interfaces 2014, 6, 319−326

ACS Applied Materials & Interfaces

Research Article

Table 1. Characteristics of Various Pd−CNT (Graphene)-Based Room Temperature H2 Sensors sensor configuration

category

substrate

electrode

1

Sa

Pd

2

S Si S S

Pd Pd Au Au/Ti

S Al2O3 glass PET S PET S Al2O3

Pd Au Cr Pd/Ti Au/Ti Pd/Ti Pd/Ti Pt Flc

S

Au

glass S

Pt Au/Ti

S S S

Au Au Au

transducer aligned SWNTs single SWNT CNT film graphene single SWNT SWNT film SWNT film SWNT film SWNTs SWNTs SWNT film SWNTs single SWNT SWNT film/ SiO2 MWNT yarns DWNTs CNT paper CNT/Ni film SWNTs/ DNA MWNT array graphene SWNT film

sensing performance Pd decoration

dynamic range (ppm)

sensitivity (% ppm−1)

N/A

25−2 × 103

0.074

N/A N/A N/A NPs

5 × 103−5 × 105

NPs NPs NPs CLsb NPs CLs NPs NPs

10−500 5 × 103−4 × 104 100−1 × 104 30−1 × 104 100−3 × 103 100−1 × 104 1−100

0.020 1.1 × 6.8 × 0.12 0.060 0.29 2.0 × 1.0 × 0.10 0.42 0.26 0.06 0.21

CLs

20−4 × 104

6.0 × 10−3

NPs NPs NPs NPs

500−3 × 104 200−1.6 × 104 100−2 × 103

0.018 −7.7 × 10−5 1.4 × 10−3 0.5

NPs NPs NPs

500−1 × 104 1−1 × 103 250−2.5 × 104

2.8 × 10−4 0.027 5.8 × 10−4

50−1 × 104

10−4 10−3

−3

10 10−4

τ50 (min)

@ H2 concentraion (%)

1.1

0.37

0.2

0.94 0.1 0.3 14 6.0 5.3 0.48 11.2 1.11 0.095 0.17

0.40 3.3 3.3

0.2 0.04 0.04 0.05 0.5 0.1 0.1 0.2 0.1 100 0.01

τ90 (min)

2.3 0.75 1.9 1.9 × 10−3 10.6 1.9 0.90 2.5

12.1 2.9 0.17 57 0.62

LDL# (ppm) 25

50