Triboelectric Nanogenerator Enabled Body Sensor Network for Self

Aug 14, 2017 - Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-struct...
0 downloads 12 Views 2MB Size
Subscriber access provided by University of Michigan-Flint

Article

Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring Zhiming Lin, Jun Chen, Xiaoshi Li, Zhihao Zhou, Keyu Meng, Wei Wei, Jin Yang, and Zhong Lin Wang ACS Nano, Just Accepted Manuscript • DOI: 10.1021/acsnano.7b02975 • Publication Date (Web): 14 Aug 2017 Downloaded from http://pubs.acs.org on August 14, 2017

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

ACS Nano is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring Zhiming Lin, † Jun Chen, ‡ Xiaoshi Li, † Zhihao Zhou, † Keyu Meng, † Wei Wei, † Jin Yang,*,† and Zhong Lin Wang*, ‡, § †

Department of Optoelectronic Engineering, Chongqing University, Chongqing 400044, China



School of Materials Science and Engineering, Georgia Institute of Technology, Atlanta, Georgia

30332, USA §

Beijing Institute of Nanoenergy and Nanosystems, Chinese Academy of Sciences, Beijing,

China *Authors to whom correspondence should be addressed. Electronic mail: [email protected] [email protected] ABSTRACT: Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, non-invasive and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless Body Sensor Network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric

ACS Paragon Plus Environment

1

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 2 of 23

power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG based generator and a TENG based sensor, an all TENG based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, non-invasive and user-friendly. KEYWORDS: self-powered body sensor network, triboelectric nanogenerator, downy-structure, power management circuit, heart-rate monitoring Owning to the quickening rhythm of human life and work as well as the population aging, healthcare monitoring has drawn increasing attentions for alerting unhealthy lifestyle and prevention of latent disease.1,

2

Heart rate, a direct reflection of the health status of human

cardiovascular system, is one of the most widely used vital sensing signal for human healthcare monitoring and diagnosis. Various efforts have been committed to develop technologies for human heart-rate monitoring.3, 4 Despite the potential and high performance, widespread usage of these techniques is possibly limited by structure complexity, fabrication of high-quality materials, and reliance on external power source.5 Recently, technologies based on Body Sensor Network (BSN), a network of associated sensor nodes on the human body, contributes largely to the personalized health monitoring and assessment, disease diagnosis. As a consequence, it would be great to develop a heart-rate BSN

ACS Paragon Plus Environment

2

Page 3 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

platform, whereby real-time heart-rate signals could be collected, transmitted and displayed.6, 7 However, the current BSNs are mainly powered by the traditional power supply unit, such as batteries. Due to the limited lifetime and the potential environmental pollutions issue of the batteries, a self-powered working module is highly desired for the BSN for heart-rate monitoring.8,9 Here, in this work, a self-powered wireless BSN system was reported for cost-effective, non-invasive and user-friendly human heart-rate monitoring. It is a systematical integration of a downy-structure based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit and Bluetooth module for wireless data transmission. By harvesting human bio-mechanical energy, a maximum power of 2.28 mW was delivered from the wearable D-TENG under the natural human walking, which is capable of driving the entire BSN system. The heart-rate signal would be processed in the signal process circuit and transmitted via the Bluetooth module, which will finally be displayed in the personal cell phone for an analysis of the daily human heart-rate information. This work not only greatly advanced the TENG in a system level for wearable medical device, but also provide a superior solution for personal heart-rate monitoring. RESULTS AND DISCUSSION The D-TENG holds a multilayer structure with acrylic as supporting backbone, as schematically shown in Figure 1a and 1b. It is consisted of two basic functional units, one unit is composed of copper back-coated PTFE thin films and copper thin films, which are stationary layers with one end being anchored onto the acrylic frame, leaving the other end free-standing. And these two kinds of films are segmentally alternating on acrylic sheets to form a downy-like

ACS Paragon Plus Environment

3

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 4 of 23

structure. The other unit are the acrylic sheets segmentally adhered on the front and back surface by the copper-coated PTFE and copper thin films as the freestanding triboelectric layers, which are finally connected to the outer frame with a stretchable rubber. Due to the innovatively designed inner downy structure, the restoring forces of the stationary layers make triboelectric layers contact fully, which is beneficial to increase the effective contact area between triboelectric layers and enhancing the electric output. This configuration is extremely sensitive to external mechanical excitation. And even a small disturbance will lead to a relative sliding between the triboelectric layers and generate power. Acrylic was selected as the structural material owing to its good strength, light weight, good machinability, and low cost. Furthermore, to enhance the triboelectrification, surface modification was performed onto the PTFE thin films via an inductively coupled plasma (ICP) to create aligned nanowire array, as the scanning electron microscopy (SEM) image shown in Figure 1c, which is capable of largely increasing the effective contact area between triboelectric layers and enhancing the electric output. Here, the copper films play dual roles of the triboelectric material and the electrode. Photographs of the inner downy structure and an as-fabricated D-TENG are respectively shown in Figure 1d and 1e. As discussed in Experimental section, the fabrication process of the D-TENG is straightforward and compatible with possible large-scale manufacturing. The operation of the D-TENG relies on relative sliding between the PTFE and copper thin films, in which a coupling between triboelectrification and electrostatic induction gives rise to alternating flow of electrons between electrodes.10-23 The electricity-generating process is elaborated through a basic functional unit in Figure 2. In the initial state, a physical contact between the PTFE and copper thin films will lead to a charge transfer at the interface due to a difference of the electron affinity between the two, which will result in a positively charged

ACS Paragon Plus Environment

4

Page 5 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

copper thin film and a negatively charged PTFE thin film (Figure 2a-I). And the insulating property of the PTFE allows a long-time retention of triboelectric charges. Once a displacement occurs due to the external mechanical excitation, the triboelectric charges are not compensated at the displaced areas, which will result in an electrical potential difference across the electrodes to drive the electrons flowing from the PTFE back electrodes to right electrodes and the freestanding copper layer (Figure 2a-II). This flow of electrons will last till the electric potential difference reaches zero (Figure 2a-III). And a further relative sliding between the two triboelectric layers will result in a reversely built potential difference between the right electrodes and the PTFE’s electrodes, which will drive the electrons to flow back from the right electrodes and the freestanding copper layer to the PTFE’s electrodes, generating a reverse current in the external circuit (Figure 2a-IV). This is a full cycle of electricity generation progress for the D-TENG. In addition, to obtain a more quantitative understanding of the working principle of D-TENG, numerical calculations of the electric field potential distribution across the electrodes under open-circuit condition are also simulated via finite element method (FEM),24-27 as demonstrated in Figure 2b, which is well consistent with the experimental observation. To investigate the D-TENG for vibration energy harvesting, a first step was taken to study the grids number depended output performance. As schematically illustrated, the inner downy structure with various grids numbers of D-TENGs are presented in Figure S1, it can be seen that the efficient triboelectric area of each grid decreases with the increase of the grids number due to the air gap increased for the same volume. All the types of D-TENGs share a same device volume and maximum sliding displacement, and all the electrical measurement was acquired under a consistent mechanical excitation at the frequency of 10 Hz. To begin with, the short-

ACS Paragon Plus Environment

5

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 6 of 23

circuit current of all the D-TENGs with various grids number are explored and displayed in Figure 3a, which reveals that all the D-TENGs are capable of delivering a stable electric output. And the current amplitudes of the D-TENG were increasing with the elevation of the grid numbers from 2 to 4 owing to an increase of the effective sliding displacement. However, it is worth noting that the current amplitudes of D-TENG decrease with the grids number from 5 to 8, which is mainly ascribed to the reducing of the effective contact area with increasing of the grid numbers and the detailed reason is demonstrated in Figure S2 and Note 1 (Supporting Information). In Figure 3b, it indicates that open-circuit voltage follows a similar trend with the short-circuit current, and a maximum value of 540V can be achieved for D-TENG with 4 grids. Furthermore, Figure 3c shows the charges generated by D-TENG with the grids number from 2 to 8. It can be observed that the transferred charges remain almost constant with the open-circuit voltage. Besides, the optimized power for different grids number have been also measured and the output power reaches the maximum with 4 grids. Given the above experimental observation, D-TENG with 4 grids is the optimized device structure with highest output performance. Additionally the D-TENG exhibits good stability in device operation. As shown in Figure S3 (Supporting Information), there is no significant change in electrical output after about 10000 cycles. For a quantitative characterization of the output performance, the electric output of the DTENG with 4 grids are systematically measured, as displayed in Figure 4. And a frequency response was first measured for the D-TENG at vibrational frequencies from 6 Hz to 10 Hz. The short-circuit currents are measured for the D-TENG with 4 grids, as shown in Figure 4a. Average peak current outputs are around 5.6 µA to 12 µA with the increase of frequency applied. And the open-circuit voltages are also demonstrated in Figure 4b and Figure S4 (Supporting

ACS Paragon Plus Environment

6

Page 7 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Information), which indicated an increasing of the output voltage from 200 to 540 V with the elevation of the external vibration frequencies. Furthermore, the transferred charges of the DTENG at different operating frequencies are shown in Figure 4c. It was found that the transferred charges increased proportionally from ~115 nC to ~306 nC with the increasing frequencies. The conversion efficiency is introduced and defined as the ratio between the input mechanical energy and the generated electric energy. And the generated electrical energy obtained by the load reaches the maximum values at a certain resistance, which can be calculated as: ‫ܧ‬௘௟௘௖௧௥௜௖௔௟ = ‫)ݐ(ܫ ׬‬ଶ ∙ ܴ ∙ ݀‫ݐ‬

(1)

where I(t) is the instantaneous current at a certain resistance, R is the load resistance. Figure 4d shows output current of the D-TENG with 4 grids at a load resistance of 80 MΩ, and the corresponding energy on the load, which is calculated to be 0.39 mJ. As for the input mechanical energy, it will be determined by the difference between potential energy at initial position and final position (equilibrium point), which can be predicted by: ଵ

‫ܧ‬௠௘௖௛௔௡௜௖௔௟ = ଶ ∙ ݇ ∙ ‫ ݔ‬ଶ

(2)

where k is the spring constant of the rubber (k = 68.2 N/m), x is its displacement. Thus, the ா೐೗೐೎೟ೝ೔೎ೌ೗

efficiency is determined by the equation ߟ = ா

೘೐೎೓ೌ೙೔೎ೌ೗

, and then the conversion efficiencies of

D-TENG with 4grids at different frequencies could be calculated, as shown in Figure 4e. The highest efficiency reaches 57.9% at the vibrational frequency of 10Hz. It clearly demonstrates the capability of harvesting mechanical energy at a very high efficiency. To further investigate the output power of the D-TENG with 4 grids, the output current is also measured with external load ranging from 1 KΩ to 1 GΩ. It remains stable when the resistance is smaller than 1 MΩ and then decreases owing to the Ohmic loss. An optimum output power of 2.28 mW is delivered at a

ACS Paragon Plus Environment

7

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

resistance of 80 MΩ as shown in Figure S5a, and the power of

Page 8 of 23

D-TENGs at different

frequencies versus external resistance plots are shown in Figure S5b (Supporting Information). Moreover, the D-TENG with 4 grids is also investigated to charge a capacitor of 10 µF at different vibrational frequency. Measured various voltage charging voltage curves by the DTENG are demonstrated in Figure 4f. As indicated, it takes 1.7 s, 2.6 s and 3.9 s to charge the capacitor up to 6 V by the D-TENG at vibrational frequency of 6 Hz, 8 Hz and 10 Hz, respectively. It is noticed that the D-TENG delivered a high voltage but relatively low current output, resulting in a large output impedance and thus affecting its applicability as a power source. And the electric output in an alternating current manner also concerns in practical applications. In this regard, a power management circuit was developed to integrate with the D-TENG to form a complete power-supplying system. Figure 5a illustrates the complete power supplying system including a TENG, a power management circuit and the commercial electronics. The power management circuit plays an important role for the power supplying system, consisting of a transformer, a rectifier, and a low leakage energy storage capacitor, as demonstrated in Figure S6 (Supporting Information). It addresses the issue of the mismatch between the electrical outputs of the TENG and the power requirement for electronics and largely improves the storage efficiency, the right insert in Figure 5a is the photograph of the power management circuit. As shown in Figure S7a (Supporting Information), the D-TENG can scavenge the inertia energy from natural human walking when it is equipped onto the human body, and a total of 42 commercial LED bulbs assembled in series can be lighted up simultaneously (see Supporting Information Video S1). Besides, the influencing factors of the output performance also explored systematically when the D-TENG is worn on the arm, as demonstrated in Note 2 (Supporting Information). The

ACS Paragon Plus Environment

8

Page 9 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

output voltage of TENG is affect by the acceleration of the sliding layer a, which is determined by the amplitude of human walking and the frequency of arm swinging. Figure S7b shows the electric output varies with different frequencies of arm swinging under a consistent amplitude. It can be observed that the open-circuit voltages present an obvious increasing tendency with the increase of frequencies of arm swinging. Furthermore, a self-powered wireless body sensor network was developed based on the power supplying system for heart-rate monitoring. As shown in Figure 5b, the self-powered wireless BSN system consisted of a commercial heart-rate sensor, signal processing unit, a Bluetooth module for data transmission as well as the power supplying system. As the arm swung naturally during walking, the harvested human bio-mechanical energy is capable of driving the BSN independently in a real-time manner. As depicted in Figure 5c, the heart-rate signal acquired by the commercial sensor would be processed in the signal process circuit which includes AD module, micro-controller and Bluetooth module. AD module will convent the analog heart-rate signal into digital signal. High precision 12-bits AD and appropriate sampling rate ensure the synchronous data acquisition with abundant details. The micro-controller would receive the digital signals from AD module for further data processing. And then the processed digital signals were sent to the smart phone via the Bluetooth module. The detected heart-rate signal will be received and displayed in real time on a personal cell phone. Figure 5d is an enlarged view showing the whole software interface of the real-time acquired heart-rate signals. The red line on the interface clearly represents the runner’s heart-rate signal, and a value of 150 bpm was obtained spontaneously (see Supporting Information Video S2). What’s more, we also developed a TENG based sensor to detect the heart-rate signal, which consists of a PTFE film and a copper film as the triboelectric layers working in single-electrode

ACS Paragon Plus Environment

9

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 10 of 23

mode.3 And it’s with the features of wearable, lightweight, self-powered, and capable of realizing health-monitoring purpose. By combining TENG-based generator and TENG-based sensor with the signal management circuit, an all-TENG based wireless BSN system was presented, as illustrated in Figure 5e. The TENG-based generator will harvest human biomechanical energy to power for the external circuits such as signal management circuit, and the TENG-based sensor could acquire real-time heart-rate information which is displayed chromatically in Figure 5f. It clearly elucidate the TENG-based sensor, management circuits and recorded real-time heart-rate signal on a personal cell phone and oscilloscope, achieving the allTENG based wireless BSN system. Figure 5g shows the heart-rate signal acquired by the TENG based sensor and commercial sensor which is a photo-electric reflective analog sensor, it can be seen that a typical characteristic pulse wave shape can be obtained from TENG based sensor with three clearly distinguishable determinants: Systolic peak (PS), point of inflection (Pi), and dicrotic wave (PD). The three parameters can be used to quantify the augmentation index and reflection index, which can accurately evaluate the physiological conditions of human cardiovascular system. However, the commercial sensor cannot detect the clear and distinct related characteristics of the heart-rate signal. Due to the self-powered, wearable, integrated features, the system will be capable of implementing the low-cost, real-time and non-invasive heart-rate monitoring, presenting a way to detect, evaluate and reveal early stages of heart diseases. A schematic illustration of self-powered wireless BSN system is also provided in Figure S10 (Supporting Information) to better show its commercial application potential. CONCLUSION To summarize, a triboelectric nanogenerator driven wireless BSN system was for reported for non-invasive real-time human heart-rate monitoring. By effectively harvesting the inertia

ACS Paragon Plus Environment

10

Page 11 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

energy of human walking, a D-TENG delivered a maximum power of 2.28 mW with total conversion efficiency of 57.9% due to the innovatively designed inner downy structure, which can immediately and sustainably power for the highly integrated wireless BSN system. Relying on the self-powered BSN, the acquired human heart-rate signals are firstly processed by a signal process circuit, then wirelessly transmitted via Bluetooth, and finally displayed onto a personal cellphone for real-time heart-rate monitoring. This work presented a competent and costeffective solution to satisfy the increasing demands of cardiopathy patients for daily healthcare monitoring, which can be immediately and extensively adopted in a variety of applications, and ultimately improving our way of living. EXPERIMENTAL SECTION Fabrication of Nanowires on PTFE Surface: A PTFE thin film with thickness of 50 µm was first washed with menthol, isopropyl alcohol, and deionized (DI) water, consecutively. And, to improve the triboelectrification, an inductively coupled plasma (ICP, SI500, SENTECH Instruments Corp.) reactive ion etching was performed to fabricate the aligned nanowires on the PTFE surface. O2, Ar and CF4 gases were injected into the ICP chamber with a flow rate of 10, 15, and 30 sccm. Plasma with a large density was produced by a power source of 400 W. And another power source of 100 W was applied in order to accelerate the plasma ions. The PTFE nanowires were obtained after an etching process for 40 seconds. Fabrication of the D-TENG: The D-TENG mainly consists of two parts: two freestanding triboelectric layers and two pairs of downy-structure stationary layers. On one hand, the freestanding triboelectric layers was firstly made by shaping a piece of acrylic sheet with a dimension of 90 mm × 70 mm × 2 mm as a substrate by using a laser cutter. Then, the copper-

ACS Paragon Plus Environment

11

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 12 of 23

coated PTFE and copper thin film with same dimension of 65 mm × 20 mm were segmentally adhered to the front and back surface of the acrylic sheets. On the other hand, downy-structure stationary layers was firstly made by cutting the acrylic sheet into a 110 mm × 70 mm × 2 mm rectangle shape by the laser cutter. And then, one edge of the PTFE films and copper thin film with same dimension of 65 mm × 30 mm were fixed on the acrylic plates in an alternating manner. To integrate, the freestanding triboelectric layers were sandwiched by two pairs of downy-structure stationary layers, followed by a final connection to the top of acrylic framework with a piece of elastic rubber. Electrical Measurement: The D-TENG was mounted onto an electrodynamic shaker (Labworks ET-139) to study the output performances at different vibrational frequencies. The shaker was driven by an amplifier (LabworkPa-13) and a functional generator (Tektronix AFG3021) with pure sinusoidal signal output. The output voltage was acquired by a programmable electrometer (Keithley Model 6514). And the output current was measured via a low-noise current preamplifier (Stanford Research System Model SR570).

ACS Paragon Plus Environment

12

Page 13 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

ASSOCIATED CONTENT Supporting Information The Supporting Information is available free of charge on the ACS Publications website at http://pubs.acs.org. Schematic illustration of the inner downy structure with various grids numbers in a DTENG (Figure S1); illustration of the efficient triboelectric area of the inner downy structure (Figure S2).cyclic test investigating the stability of the D-TENG (Figure S3); relationship between frequency and electrical output of as-fabricated TENG with 4 grids (Figure S4); the measured the output power of the D-TENG versus external load resistance (Figure S5); diagram of the power management circuit (Figure S6); harvesting energy from natural vibration of human walking (Figure S7); theoretical model of metal-to-dielectric sliding mode (Figure S8); mechanical spring mass-damper model (Figure S9); schematic illustration of self-powered wireless body sensor network (Figure S10) (PDF) Video S1: triboelectric nanogenerator harvesting vibration energy from human walking (AVI) Video S2: self-powered heart-rate monitoring system (AVI) The authors declare no competing financial interest. AUTHOR INFORMATION Corresponding Authors *E-mail: [email protected] *E-mail: [email protected]

ACS Paragon Plus Environment

13

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 14 of 23

ORCID Zhong Lin Wang: 0000-0002-5530-0380 Author Contributions Z. Lin, and J. Chen contributed equally to this work. ACKNOWLEDGMENT This work was supported by the National Natural Science Foundation of China (Nos. 51675069, 51475060), and graduate scientific research and innovation foundation of Chongqing, China (Grant No. CYB17017). REFERENCES (1) Niu, S.; Wang, X.; Yi, F.; Zhou, Y. S.; Wang, Z. L. A Universal Self-Charging System Driven by Random Biomechanical Energy for Sustainable Operation of Mobile Electronics. Nat. Commun. 2015, 6, 8975. (2) Zhong, J.; Zhong, Q.; Hu, Q.; Hu, B.; Wang, Z. L.; Zhou, J. Fiber-Based Generator for Wearable Electronics and Mobile Medication. ACS Nano 2014, 8, 6273-6280. (3) Yang, J.; Chen, J.; Su, Y.; Jing, Q.; Li, Z.; Yi, F.; Wen, X.; Wang, Z.; Wang, Z. L. EardrumInspired Active Sensors for Self-Powered Cardiovascular System Characterization and ThroatAttached AntiInterference Voice Recognition. Adv. Mater. 2015, 27, 1316-1326. (4) Pu, X.; Li, L.; Song, H.; Du, C.; Zhao, Z.; Jiang, C.; Cao, G.; Hu, W.; Wang, Z. L. A SelfCharging Power Unit by Integration of a Textile Triboelectric Nanogenerator and a Flexible Lithium-Ion Battery for Wearable Electronics. Adv. Mater. 2015, 27, 2472-2478.

ACS Paragon Plus Environment

14

Page 15 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

(5) Rendon-Morales, E.; Prance, R. J.; Prance, H.; Aviles-Espinosa, R. Non-Invasive Electrocardiogram Detection of in vivo Zebrafish Embryos Using Electric Potential Sensors. Appl. Phys. Lett. 2015, 107, 193701. (6) Pirbhulal, S.; Zhang, H.; Mukhopadhyay, S. C.; Li, C.; Wang, Y.; Li, G.; Zhang, Y. T. An Efficient Biometric-Based Algorithm Using Heart Rate Variability for Securing Body Sensor Networks. Sensors 2015, 15, 15067-15089. (7) Hao, Y.; Foster, R. Wireless Body Sensor Networks for Health-Monitoring Applications. Physiol. Meas. 2008, 29, R27. (8) Trung, T. Q.; Lee, N. E. Flexible and Stretchable Physical Sensor Integrated Platforms for Wearable Human-Activity Monitoringand Personal Healthcare. Adv. Mater. 2016, 28, 43384372. (9) Khan, Y.; Ostfeld, A. E.; Lochner, C. M.; Pierre, A.; Arias, A. C. Monitoring of Vital Signs with Flexible and Wearable Medical Devices. Adv. Mater. 2016, 28, 4373-4392. (10) Zhu, G.; Chen, J.; Zhang, T.; Jing, Q.; Wang, Z. L. Radial Arrayed Rotary Electrification for High Performance Triboelectric Generator. Nat. Commun. 2014, 5, 3426. (11) Zhu, G.; Pan, C.; Guo, W.; Chen, C. Y.; Zhou, Y.; Yu, R.; Wang, Z. L. TriboelectricGenerator-Driven Pulse Electrodeposition for Micropatterning. Nano Lett. 2012, 12, 4960-4965. (12) Yang, J.; Chen, J.; Yang, Y.; Zhang, H.; Yang, W.; Bai, P.; Wang, Z. L. Broadband Vibrational Energy Harvesting Based on a Triboelectric Nanogenerator. Adv. Energy Mater. 2014, 4, 1301322. (13) Chen, J.; Zhu, G.; Yang, W.; Jing, Q.; Bai, P.; Yang, Y.; Wang, Z. L. Harmonic-ResonatorBased Triboelectric Nanogenerator as a Sustainable Power Source and a Self-Powered Active Vibration Sensor. Adv. Mater. 2013, 25, 6094-6099.

ACS Paragon Plus Environment

15

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 16 of 23

(14) Yang, J.; Chen, J.; Liu, Y.; Yang; W.; Su, Y.; Wang, Z. L. Triboelectrification-Based Organic Film Nanogenerator for Acoustic Energy Harvesting and Self-Powered Active Acoustic Sensing. ACS nano 2014, 8, 2649-2657. (15) Wang, Z. L.; Chen, J.; Lin, L. Progress in Triboelectric Nanogenerators as a New Energy Technology and Self-Powered Sensors. Energy Environ. Sci. 2015, 8, 2250−2282. (16) Zhu, G.; Peng, B.; Chen, J.; Jing, Q.; Wang, Z. L. Triboelectric Nanogenerators as a New Energy Technology: From Fundamentals, Devices, to Applications. Nano Energy 2015, 14, 126138. (17) Tang, W.; Tian, J.; Zheng, Q.; Yan, L.; Wang, J.; Li, Z.; Wang, Z. L. Implantable SelfPowered Low-Level Laser Cure System for Mouse Embryonic Osteoblasts’ Proliferation and Differentiation. ACS nano 2015, 9, 7867-7873. (18) Yang, W.; Chen, J.; Wen, X.; Jing, Q.; Yang, J.; Su, Y.; Wang, Z. L. Triboelectrification Based Motion Sensor for Human-Machine Interfacing. ACS Appl. Mater. Inter. 2014, 6, 74797484. (19) Chen J, Huang Y, Zhang N, Zou H.; Liu, R.; Tao, C.; Fan, X.; Wang, Z. L. Micro-Cable Structured Textile for Simultaneously Harvesting Solar and Mechanical Energy. Nat. Energy 2016, 1, 16138. (20) Lee, S.; Ko, W.; Oh, Y.; Lee, J.; Baek, G.; Lee, Y.; Hong, J. Triboelectric Energy Harvester Based on Wearable Textile Platforms Employing Various Surface Morphologies. Nano Energy 2015, 12, 410-418. (21) Zi, Y.; Wang, J.; Wang, S.; Li, S.; Wen, Z.; Guo, H.; Wang, Z. L. Effective Energy Storage from A Triboelectric Nanogenerator. Nat. Commun. 2016, 7, 10987.

ACS Paragon Plus Environment

16

Page 17 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

(22) Chen, J.; Zhu, G.; Yang, J.; Jing, Q.; Bai, P.; Yang, W.; Wang, Z. L. Personalized Keystroke Dynamics for Self-Powered Human-Machine Interfacing. ACS nano 2015, 9, 105-116. (23) Zhong, J.; Zhu, H.; Zhong, Q.; Dai, J.; Li, W.; Jang, S. H.; Zhou, J. Self-Powered HumanInteractive Transparent Nanopaper Systems. ACS nano 2015, 9, 7399-7406. (24) Chen, J.; Yang, J.; Li, Z.; Fan, X.; Zi, Y.; Jing, Q.; Wang, Z. L. Networks of Triboelectric Nanogenerators for Harvesting Water Wave Energy: A Potential Approach toward Blue Energy. ACS nano 2015, 9, 3324-3331. (25) Fan, X.; Chen, J.; Yang, J.; Bai, P.; Li, Z.; Wang, Z. L. Ultrathin, Rollable, Paper-Based Triboelectric Nanogenerator for Acoustic Energy Harvesting and Self-Powered Sound Recording. ACS nano 2015, 9, 4236-4243. (26) Wen, Z.; Chen, J.; Yeh, M. H.; Guo, H.; Li, Z.; Fan, X.; Wang, Z. L. Blow-Driven Triboelectric Nanogenerator as an Active Alcohol Breath Analyzer. Nano Energy 2015, 16, 3846. (27) Niu, S.; Liu, Y.; Wang, S.; Lin, L.; Zhou, Y. S.; Hu, Y.; Wang, Z. L. Theory of SlidingMode Triboelectric Nanogenerators. Adv. Mater. 2013, 25, 6184-6193.

ACS Paragon Plus Environment

17

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 18 of 23

FIGURES

TOC graphic

ACS Paragon Plus Environment

18

Page 19 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Figure 1. Structural design of the downy-structured triboelectric nanogenerator (D-TENG). (a) A schematic illustration of (a) the process flow and (b) device structure of the D-TENG. (c) A SEM image of the PTFE polymer nanowire array. Photograph of (d) the inner structure and (e) an asfabricated D-TENG.

ACS Paragon Plus Environment

19

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 20 of 23

Figure 2. Electricity generation process of the D-TENG. Two dimensional (a) schematic illustration and (b) finite element simulations of showing the working principle of the D-TENG.

ACS Paragon Plus Environment

20

Page 21 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Figure 3. Electrical characterization of the D-TENG. Dependence of the (a) short-circuit current, (b) open-circuit voltage, (c) transfer change quantity and (d) power of the D-TENG with different grid numbers under a consistent mechanical excitation of 10 Hz.

ACS Paragon Plus Environment

21

ACS Nano

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

Page 22 of 23

Figure 4. Electrical output performances of the D-TENG with 4 grids inner downy structure. (a) Dependence of the short-circuit current of the D-TENG on the external vibration frequency from 6 Hz to 10 Hz. (b) Dependence of the open-circuit voltage of D-TENG on the external vibration frequency from 6 Hz to 10 Hz. (c) The transfer charge quantity of the D-TENG. (d) The output current at a load resistance of 80 MΩ and the energy on the load resistance. (e) The electromechanical conversion efficiencies of D-TENG. (f) Measured various voltage charging curves of a 10 µF capacitor driven by the D-TENG.

ACS Paragon Plus Environment

22

Page 23 of 23

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60

ACS Nano

Figure 5. Demonstrations of the integrated power-supplying system for driving and charging electronics. (a) System diagram of the complete power-supplying system. (b) Photograph showing the integrated system was equipped onto a human arm. (c) Photograph showing the acquired heart-rate data was wirelessly transmitted to a cell phone in a real-time manner. (d) An enlarged view to show the whole software interface of the real-time acquired heart-rate signals. (e) Diagram of all TENG-based wireless BSN system. (f) Demonstration of all TENG-based wireless BSN system and the acquired real-time heart-rate information displayed on personal phone. (g) Heart-rate signal acquired by (I) TENG based sensor, and (II) commercial sensor.

ACS Paragon Plus Environment

23