Subscriber access provided by READING UNIV
Article
Unveiling the Susceptibility of Functional Groups of Polyethersulfone/Polyvinylpyrrolidone Membranes to NaOCl: A Two-Dimensional Correlation Spectroscopic Study Zhongbo Zhou, Guocheng Huang, Yi Xiong, Minghao Zhou, Shaoqing Zhang, Chuyang Y. Tang, and Fangang Meng Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.7b03952 • Publication Date (Web): 14 Nov 2017 Downloaded from http://pubs.acs.org on November 15, 2017
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 33
Environmental Science & Technology
1
2
Unveiling the Susceptibility of Functional Groups of
3
Polyethersulfone/Polyvinylpyrrolidone Membranes to NaOCl:
4
A Two-Dimensional Correlation Spectroscopic Study
5 6
Zhongbo Zhou a,b, Guocheng Huang a,b, Yi Xionga,b, Minghao Zhoua,b, Shaoqing Zhang a,b, Chuyang Y. Tang c, Fangang Menga,b*
a
School of Environmental Science and Engineering, Sun Yat-sen University, Guangzhou 510006, PR China b Guangdong Provincial Key Laboratory of Environmental Pollution Control and Remediation Technology, Sun Yat-sen University, Guangzhou 510275, China c Department of Civil Engineering, The University of Hong Kong, Pokfulam, Hong Kong
17
*
Corresponding author.
18
Fangang MENG, Ph. D., Email:
[email protected] 7 8 9 10 11 12 13 14 15 16
19 20 21 22 23
1
ACS Paragon Plus Environment
Environmental Science & Technology
24
TOC:
25 26
27 28
2
ACS Paragon Plus Environment
Page 2 of 33
Page 3 of 33
Environmental Science & Technology
29
ABSTRACT: A clear understanding of membrane ageing process is essential for the
30
optimization of chemical cleaning in membrane-based facilities. In this study,
31
two-dimensional
32
spectroscopy (COS) analysis was firstly used to decipher the sequential order of
33
functional group changes of NaOCl-aged polyethersulfone/polyvinylpyrrolidone
34
(PES/PVP) membranes. The synchronous maps showed twelve major autopeaks in
35
total. Based on the asynchronous maps, a similar ageing sequence of membrane
36
groups was clearly identified at three pHs (i.e., 6, 8 and 10): 1463, 1440, and 1410
37
(cyclic C-H structures) > 1662 (amide groups) > 1700 (succinimide groups) > 1320,
38
1292 (S=O asymmetric) > 1486, 1580 (aromatic structures) > 1241 (aromatic ether
39
bands) > 1105, 1150 cm-1 (O=S=O symmetric). Among them, membrane chlorination
40
occurred at 1241, 1410 and 1440 cm-1. Moreover, the initial degradation of PVP and
41
the subsequent transformation of PES could be highly responsible for the increased
42
water permeability and the enlargement of membrane pores, respectively, both
43
leading to serious fouling with humic acid filtration. In summary, the 2D-FTIR-CoS
44
analysis is a powerful approach to reveal the interaction mechanisms of
45
NaOCl-membrane and could be also useful to probe the process of membrane
46
fouling and chemical cleaning.
(2D)
Fourier
transformation
infrared
47 48 49 50 51 52 3
ACS Paragon Plus Environment
(FTIR)
correlation
Environmental Science & Technology
53
INTRODUCTION
54
Over the past few years, membrane technologies have been increasingly used in
55
diverse fields (e.g., wastewater treatment and reuse, drinking water purification, pure
56
water production and desalination) because of their good capability to reject a wide
57
spectrum of contaminants1, 2. Despite of these advantages, membrane fouling
58
remains a critical issue and often requires periodical chemical cleaning3, 4. The harsh
59
environment during chemical cleaning can result in accelerated membrane ageing,
60
with major changes in pore size, surface properties, and chemical bonds5. These
61
changes, in turn, impacts the interaction between membranes and foulants, and thus
62
the redevelopment of fouling6. Therefore, a comprehensive understanding on the
63
membrane ageing process is of great importance for the optimization of chemical
64
cleaning in membrane-based facilities.
65
Sodium hypochlorite (NaOCl) is one of the most popular cleaning reagents3.
66
Nevertheless, NaOCl is known to cause chemical degradation of common membrane
67
materials such as polysulfone (PSf) and polyethersulfone (PES)5. For example,
68
exposure of PES to NaOCl can result in the chain scission of C-S bonds7-9 and the
69
breakage of PES chains10, which often leads to increased pore sizes and decreased
70
tensile strength of membranes10,
71
complicated by the presence of macromolecular additives12-14 such as polyethylene
72
glycol (PEG)15 or polyvinylpyrrolidone (PVP)16-18. Despite the vast literature on
73
membrane ageing, the dynamic ageing process is not fully understood. Traditional
74
one-dimensional Fourier transform infrared (FTIR) spectra, a most widely used tool
11
. In fact, membrane ageing can be further
4
ACS Paragon Plus Environment
Page 4 of 33
Page 5 of 33
Environmental Science & Technology
75
for studying the changes in chemical bonding information, often suffer in
76
overlapping problems among different bands19, resulting in poor resolution of the
77
molecular-level details. In particular, traditional FTIR spectra fail to clarify the
78
sequential order of different functional group changes during the membrane aging
79
process. More recently, electrokinetic characterizations were proposed to provide
80
important clues on the sequential changes of some ionizable groups of NaOCl-aged
81
membranes20. Nonetheless, the changes in considerable functional groups of
82
membranes cannot be well identified. Hence, more direct molecular-level evidences
83
on the sequential interactions between different functional groups of membranes and
84
NaOCl need to be clarified. Moreover, the corresponding changes in membrane
85
performance as a function of membrane group degradation need to be systematically
86
studied.
87
Two-dimensional correlation spectroscopy (2D-CoS), based on a set of FTIR
88
spectra in response to some external perturbations (e.g., pH, temperature, and
89
oxidant concentration), can potentially reveal the sequential changes of different
90
functional groups21, 22. In recent years, 2D-FTIR CoS analysis has been successfully
91
applied to study the interaction mechanism of metals23 and nanomaterials24, 25 with
92
various substrates such as macromolecules26 and bacteria27. The method was also
93
capable to resolve the dynamic diffusion process of water and CaCl2 in a
94
polyacrilonitrile membrane28. These inspiring studies prompted us to apply
95
2D-FTIR-CoS to characterize the dynamic ageing process of membranes exposed to
96
NaOCl. It can be expected that the use of 2D-FTIR-CoS can provide a clearer picture 5
ACS Paragon Plus Environment
Environmental Science & Technology
97
Page 6 of 33
on the degradation mechanisms of membranes during the exposure to NaOCl.
98
In this study, we employed the FTIR spectra integrated with 2D-CoS analysis to
99
systematically examine chemical structure variations of a PVP modified PES
100
membrane under various NaOCl exposure conditions. Our study can provide direct
101
molecular-level insights on the ageing sequence of functional groups of NaOCl-aged
102
membranes and the consequent impact on the membrane properties (e.g., pure water
103
permeability, surface morphology and fouling behavior).
104
MATERIALS AND METHODS
105
Membranes. A commercial flat-sheet PES membrane with a molecular weight
106
cut-off of 150 kDa (UP150, Microdyn-Nadir, Germany) was used. Based on FTIR
107
and X-ray photoelectron spectroscopy (XPS) analysis, the active layer of the PES
108
membraneis blended with PVP (i.e., a PEV/PVP membrane). The support and
109
drainage layer of the membrane is composed of non-woven polyester fabric.
110
According to the manufacturer, the maximum chlorine resistance of the membrane is
111
up to 500,000 ppm·h, and the membrane can be operated at a wide range of pH (1-14)
112
and at high temperature (max. 95 °C). Prior to ageing assays, disks of the virgin
113
membrane (diameter=85 mm) were rinsed with and soaked in ultrapure water (18.2
114
MΩ cm, RSJ Corp., China) for approximately 24 h to remove impurities.
115
Chemicals. All the solutions were prepared with the ultrapure water. NaOCl (reagent
116
grade, available chlorine 4.00-4.99%) was purchased from Sigma-Aldrich. The free
117
chlorine
118
(N,N-diethyl-p-phenylenediamine) method29. Solution pH was adjusted using 1 M
concentration
was
determined
6
ACS Paragon Plus Environment
by
the
DPD
Page 7 of 33
Environmental Science & Technology
119
hydrochloric acid and 1 M sodium hydroxide solutions (AR-grade., Da-Mao Corp.,
120
China).
121
Membrane ageing assays. The pristine membrane disks were submerged in NaOCl
122
solutions (300 ppm total free chlorine, pH at 6, 8 or 10, 25 ± 2 °C) in sealed glass
123
bottles in the dark. Exposure time ranged from 0.5 to 30 d, during which NaOCl
124
replenishment and pH adjustment were performed periodically to maintain constant
125
free chlorine concentration and solution pH. The maximum exposure dose of 216,
126
000 ppm·h, corresponding to the 30-d exposure, is below the maximum chlorine
127
resistance of the membrane (500,000ppm·h). The NaOCl-exposed membranes were
128
thoroughly cleaned with the ultrapure water to remove residual chlorine and then
129
stored at 4 °C under humid conditions before further characterization.
130
Physicochemical characteristic analysis. The membrane samples were first
131
freeze-dried under a vacuum at -57°C for 48 h to remove residual moisture. FTIR
132
spectrometry with an attenuated total reflectance accessory (ATR-FTIR) (EQUINOX
133
55, Bruker, Germany) was employed to monitor the changes in functional groups of
134
the membranes after NaOCl exposure. Each spectrum was the average of 16 scans
135
recorded over 4000-650 cm-1 at a resolution of 2 cm-1. Meanwhile, an XPS
136
instrument with Al Kα (1486.6 eV) radiation (ESCALAB 250, Thermo-VG
137
Scientific) was used to scan the aged membranes in a broad survey scan with 20-eV
138
pass energy. A high-resolution scan with 80-eV pass energy was applied for the
139
component speciation. Moreover, the surface morphology of aged membranes (after
140
coating with gold) was observed by scanning electron microscopy (SEM) 7
ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 33
141
(JSM-6330F, JEOL, Japan).
142
2D-CoS analysis. In this study, the exposure time was used as an external
143
perturbation for the functional group changes of the PES/PVP membrane during the
144
ageing assays. Based on the work of Noda and Ozaki22, a set of time-dependent
145
ATR-FTIR spectra collected above were employed for the 2D correlation analysis.
146
Briefly, y(x, t) as the variations of analytical spectra as a function of a spectral
147
variable (x, wavenumber in IR spectra) and a perturbation variable (t, exposure time)
148
can be used for the definition of dynamic spectra y(x, t) as follows: , − for T ≤ ≤ T ; (x, t)= 0, others;
149
(1)
150
In Eq. (1), the reference spectrum is typically set as the time-averaged y(x, t),
151
i.e., , /T − T , where Tmin and Tmax denote the minimum
152
and maximum value of the exposure time, respectively.
153
According to the Hilbert-Noda transform method21,
22
, the 2D correlation
154
synchronous (Φ(x1, x2)) and asynchronous (Ψ(x1, x2)) spectral maps can be generated
155
from the corresponding dynamic spectra as follows:
156 157
Φ(x1, x2) =
,
· " , ;
(2)
158 159
Ψ(x1, x2) =
,
· #̃ " , ;
(3)
160 " , & %
161
where #̃ " , =
162
" , and & is the integral variable (i.e., time). The value of Φ(x1, x2) represents
· '(
'
& is the Hilbert transform of the signal
8
ACS Paragon Plus Environment
Page 9 of 33
Environmental Science & Technology
163
the simultaneous or coincidental changes of spectral intensity variations observed at
164
x1 and x2 during the interval between Tmin and Tmax. In contrast, the intensity of Ψ(x1,
165
x2) represents the asynchrony of spectral intensity variations measured at x1 and x2,
166
which can reveal the sequential order of spectral intensity changes by the external
167
perturbation. Exact rules of determining such order of the spectral intensity changes
168
are present here: (1) If the intensity of the synchronous spectrum is positive (Φ(x1,
169
x2) > 0), the positive cross peak (Ψ(x1, x2) > 0) of the asynchronous spectrum reflects
170
that the intensity change at x1 occurs before x2 while the negative cross peak (Ψ(x1,
171
x2) < 0) reflects that the change at x1 occurs after x2. (2) If the intensity of the
172
synchronous spectrum is negative (Φ(x1, x2) < 0), the above rule is reversed. Prior to
173
the 2D-CoS analysis, all the ATR-FTIR spectra were normalized, baseline-corrected,
174
and denoised by Savitzky-Golay Smoothing. All the calculations above were
175
conducted with MatlabR2010a (MathworksInc., USA) and 2Dshige software
176
(Shigeaki Morita, Japan).
177
Membrane performance tests. The side-effect of chemical changes of membranes
178
on their performance was investigated with a stirred dead-end filtration cell (an
179
effective area of 37.4 cm2, MSC300, Mosu Corp., Shanghai, China). During the
180
filtration, the rotating speed was maintained at 350 rpm and the pressure was fixed at
181
69 kPa. The permeate amount was recorded automatically by an electronic scale
182
connecting with a personal computer. The aged membranes were first soaked in the
183
ultrapure water for 24 h, and then their water permeability was measured with 300
184
mL ultrapure water. Afterwards, humic acid (HA, Sigma-Aldrich) with a 9
ACS Paragon Plus Environment
Environmental Science & Technology
185
concentration of 10 mg DOC/L was used as a model foulant to perform fouling tests
186
for the aged membranes. Unless specified otherwise, all parameters in the fouling
187
and permeability tests are the same. Finally, the unified membrane fouling index
188
(UMFI) was calculated to evaluate the fouling propensity of the aged membranes30.
189
RESULT AND DISCUSSION
190
ATR-FTIR spectra of NaOCl-aged PES/PVP membranes. As shown in Fig. 1, the
191
variations of IR absorption peaks were mainly concentrated in the region of
192
1800-1000 cm-1. The characteristic bands of PES (i.e., 1580, 1486, 1320, 1292, 1241,
193
1150, and 1105 cm-1) exhibited high absorption intensities in the IR spectra of
194
pristine membranes (0 day)
195
related to aromatic ring groups; ii) bands located at 1320/1292 and 1150/1105 cm-1
196
are attributed to the asymmetric and symmetric stretching vibrations of sulfone
197
groups (Ar-SO2-Ar), respectively; and iii) strong peaks at 1241 cm-1 are due to the
198
presence of aromatic ether structures (Ar-O-Ar). Moreover, a number of
199
characteristic peaks (i.e., 1662, 1463, 1440 and 1410 cm-1) representing PVP were
200
observed in the IR spectra20. For instance, the bands located at 1463, 1440 and 1410
201
cm-1 are associated with the cyclic C-H structures of pyrrolidine of PVP33.
202
Additionally, the band at 1662 cm-1 is assigned to the C=O vibration of amide groups,
203
which was further confirmed by the XPS data that the pristine membrane contained
204
3.45 % nitrogen atom (Table S1). Previous studies also reported that the pure PES
205
membranes had no absorption band at 1662 cm-1 12, 34. These findings confirm that
206
the commercial PES membrane employed in this study is blended with some PVP.
10, 31, 32
: i) two typical peaks at 1580 and 1486 cm-1 are
10
ACS Paragon Plus Environment
Page 10 of 33
Page 11 of 33
Environmental Science & Technology
207 208
Figure 1. ATR-FTIR spectra (1000-1800 cm-1) of PES/PVP membranes upon exposure to
209
NaOCl at three different pHs of 6 (a), 8 (b), and 10 (c) as a function of exposure time (0-30
210
days). 11
ACS Paragon Plus Environment
Environmental Science & Technology
211
Moreover, the ATR-FTIR spectra also showed that the variation of membrane
212
functional groups was impacted significantly by the pH of NaOCl. The decreasing
213
degree of spectral peak intensities between 1800-1000 cm-1 became weaker with
214
increasing pHs. Particularly, the treatment of NaOCl at pH 6 induced drastic
215
degradation of the amide group (N-C=O) at 1662 cm-1 as well as the generation of a
216
new shoulder peak at 1700 cm-1 representing the formation of succinimide groups20.
217
In contrast, the shoulder peak at 1700 cm-1 was much weak at pH 8 and nearly absent
218
at pH 10, which is consistent to the finding by Kourde-Hanafi et al.16. A possible
219
explanation is that the succinimide groups formed could be further degraded or
220
released at higher pHs35. Moreover, the two small peaks at 1440 and 1463 cm-1
221
involving in the cyclic C-H structures of PVP almost disappeared at pH 6 and 8 with
222
increasing exposure time, further indicating that the characteristic structures
223
involving in PVP were destructed. However, the 30-day exposure of NaOCl at pH 10
224
just led to a slight decrease in the band intensity of the IR spectra. These results
225
imply that the ageing rate of PES/PVP membranes strongly depends on the pH of
226
NaOCl solutions36-38. Unfortunately, the traditional one-dimensional FTIR spectra
227
analysis suffers from giving limited information on the dynamic ageing process at
228
different pHs, and especially fails to probe the change order of functional groups of
229
NaOCl-aged PES/PVP membranes.
230
2D-CoS maps on the ageing processof PES/PVP membranes. As seen in Fig. 2a,
231
c,e, the synchronous maps at three pHs were almost similar in the distribution of
232
peaks. Twelve major autopeaks were identified at 1105, 1150, 1241, 1292, 1320, 12
ACS Paragon Plus Environment
Page 12 of 33
Page 13 of 33
Environmental Science & Technology
233
1410, 1440, 1463, 1486, 1580, 1662, and 1700 cm-1 along the diagonal line.
234
Regardless of the pH, peaks at 1105/1150 and 1241 cm-1 involving in the sulfone
235
groups and aromatic ether had the highest intensity, followed by the peaks at 1662
236
and 1486/1580 cm-1 (the amide and aromatic structures, respectively) while the
237
cyclic C-H structures at 1410, 1440 and 1463 cm-1 had the lowest intensity.
238
Regarding the controversial peak at around 1030 cm-1 likely attributed to sulphonic
239
acids groups or phenolic groups, there was no autopeak found in this work, which
240
could be related to the low amount of PVP in the membrane used in this study (less
241
than 5%). Prulho et al. only observed the formation of the weak band at 1030 cm-1 in
242
the aged PES membrane with a high PVP up to 50%18. Moreover, these autopeaks at
243
pH 6 and 8 had a higher intensity than those at pH 10 (Fig. 2a, c, e), clearly
244
revealing that the PES/PVP membranes are more susceptible to be degraded by
245
NaOCl at pH 6 and 838. Notably, the intensity of the autopeak at 1662 cm-1at pH 6
246
and 8 was around ten times stronger than that at pH 10. This demonstrates that the
247
amide structures of PVP are much more sensitive to NaOCl compared to the
248
characteristic bands of PES36. Majority of cross peaks in the synchronous maps at
249
three pHs had a positive sign (Table 1), suggesting that almost all the functional
250
groups underwent synchronously changes (i.e., decreases in the intensity of bands)
251
during the ageing process of PES/PVP membranes. Nevertheless, the negative sign
252
of all cross peaks (Φ(x1, 1700) < 0) at pH 6 demonstrated that the change direction of
253
peak at 1700 cm-1 was opposite to that of other groups in the range of 1000-1662
254
cm-1, as a result of the increasing intensity of peak at 1700 cm-1 with increasing 13
ACS Paragon Plus Environment
Environmental Science & Technology
255
exposure time. It is of great interest that the cross peaks (Φ(x1, 1700)) at pH 8
256
showed negative signs for x1 at 1292, 1320, 1410, 1440, 1463, and 1662 cm-1,but no
257
sign for x1 at 1105, 1150, 1241, 1486, and 1580 cm-1. Apparently, these above results
258
give direct evidences on the formation of succinimide groups at 1700 cm-1, occurring
259
with the transformation of cyclic C-H structures (1410-1463 cm-1) and amide groups
260
at 1662 cm-1of PVP39. Meanwhile, it further confirmed that the oxidization or
261
hydrolysis of succinimide groups occurred at pH 8 in contrast to the accumulation of
262
this band at pH 616, 18. However, at pH 10, the autopeak at 1700 cm-1was no longer
263
observable and all the cross peaks had no sign (Table 1). This could be related to
264
two reasons: i) NaOCl solutions at pH 10 are mainly composed of the ion of ClO- (>
265
90 %), which has a lower production potential of·OH and ·C1O radicals causing a
266
weaker oxidative capacity40; ii) Moreover, the ring opening of pyrrolidine occurs in
267
alkaline solutions (pH 8 and 10)18,
268
ATR-FTIR spectra, the synchronous maps of 2D-CoS analysis can provide more
269
deep insights into the changes in membrane functional groups induced by NaOCl,
270
and especially on the relationships among molecular structure variations.
35
. Overall, in comparison to the general
271
Based on the Noda’s rules21 described before, asynchronous correlation spectra
272
can reveal the sequential order of specific chemical reactions during the ageing
273
process of PES/PVP membranes. The asynchronous map is antisymmetric with
274
respected to the diagonal line and thus displayed no autopeak. In Fig. 2b, d and f,
275
distinctive differences in the sign of cross peaks were found among the three pHs. As
276
shown in Table 1, at pH 6, most of the cross peaks (Ψ(x1, 1700)) showed a positive 14
ACS Paragon Plus Environment
Page 14 of 33
Page 15 of 33
Environmental Science & Technology
277
sign apart from those at 1410, 1440, 1463 and 1662 cm-1, indicating that the
278
increasing intensity of the peak at 1700 cm-1 occurred after the decreasing intensity
279
of the peak at 1410, 1440, 1463 and 1662 cm-1 but before others (i.e., 1105, 1150,
280
1241, 1292, 1320, 1486, and 1580 cm-1). Moreover, negative signs were observed at
281
the cross peaks of Ψ(x1, 1292/1320/1410/1440/1463), implying that the spectral
282
decreases at 1292, 1320, 1410, 1440, and 1463 cm-1 occurred prior to the decreasing
283
peaks at 1105, 1150, and 1241 cm-1. In addition, six negative cross peaks at Ψ(1105,
284
1486/1580), Ψ(1150, 1486/1580), and Ψ(1241, 1486/1580) were observed, indicating
285
that the change sequence of bands at 1486/1580 cm-1 occurred earlier than those at
286
1241, 1150 and 1105 cm-1. In conclusion, the ageing process of PES/PVP
287
membranes at pH 6 could occur in the following sequence: 1463, 1440, and 1410
288
(cyclic C-H structures) >1662 (amide groups)> 1700 (succinimide groups)> 1320,
289
1292 (S=O asymmetric) >1486, 1580 (aromatic structures) > 1241 (aromatic ether
290
bands) > 1105, 1150cm-1 (O=S=O symmetric).
15
ACS Paragon Plus Environment
Environmental Science & Technology
291 292
Figure 2. Synchronous (a, c, e) and asynchronous (b, d, f) 2D correlation maps constructed
293
from time-dependent ATR-FTIR spectra of PES/PVP membranes in the treatment of
294
NaOCl at three different pHs of 6, 8 and 10. Red color denotes positive correlation, and blue
295
color means negative correlation; darker color demonstrates a higher intensity and thus a
296
stronger positive or negative correlation. In 2D-CoS maps, the peaks located at the diagonal line
297
are called auto-peaks while cross peaks are located off-diagonal positions.
298 16
ACS Paragon Plus Environment
Page 16 of 33
Page 17 of 33
Environmental Science & Technology
299
Likewise, according to the sign of 2D-CoS maps at pH 8, the sequential order
300
of band changes followed 1463, 1440, and 1410 > 1662 > 1292, 1320 > (1700) >
301
1486, 1580 > 1241 > 1150, 1105 cm-1. It demonstrated that the degradation of groups
302
involving in PVP also occurred earlier than the scission of Ph-SO2-Ph chains,
303
followed by the variation of aromatic ether of PES. However, some cross peaks
304
(Φ(x1, 1700) and Ψ(x1, 1700)) in the 2D-CoS maps showed no sign at pH 8. As such,
305
it was unable to identify the change order of band at 1700 cm-1 except for probing
306
that the formation of succinimide groups at 1700 cm-1 followed the changes of cyclic
307
structures and amide groups of PVP (1410/1440/1463 and 1662 cm-1). At pH 10, the
308
sequential order of band changes was identified as 1463, 1440, and 1410 > 1662 >
309
1320, 1292 > 1486, 1580, 1241, 1150, 1105 cm-1. Expectedly, the variations of the
310
bands (1463, 1440, 1410 and 1662 cm-1) involving in the PVP material still occurred
311
initially whereas the C-H structure of aromatic ring (1486 and 1580 cm-1) and the
312
aromatic ether (1241 cm-1) of PES was attacked less and hardly changed at pH 10.
313
Accordingly, the XPS high-resolution C s1, N s1, O s1 and Cl 2p data (Fig. S2) only
314
showed slight changes with the exposure time at pH 10. Several previous studies
315
also reported that the NaOCl solution under a stronger alkaline condition had less
316
impact on membrane functional groups and properties (e.g., surface charges,
317
elongation at break and tensile strength)10, 36, 38.
318
Generally, regardless of the pH, the dynamic ageing process of PES/PVP
319
membranes by NaOCl is almost similar except for the diverse degradation rate of
320
functional groups. As a first step, the C-H vibration of the cyclic structure of PVP 17
ACS Paragon Plus Environment
Environmental Science & Technology
Page 18 of 33
321
was attacked readily by unstable ·OH radicals, especially in the α-position of the
322
amide group41 (Fig.S4). Through mass spectrometry analysis, Foutquet et al.39 also
323
observed the hydrogen abstraction of the PVP exposed to NaOCl. Subsequently, the
324
amide groups (1662 cm-1) of PVP were greatly impacted, and then the succinimide
325
groups formed at 1700 cm-1 were observed18, 41. These reactions could be further
326
revealed by the XPS spectra (Fig. S1 and S2), e.g., with increasing exposure time,
327
the proportion of C-(C, H) decreased while the functional group of C=O increased
328
(Table S1). Additionally, increasing proportion of protonated nitrogen as a function
329
of exposure time further confirmed the destruction of pyrrolidine structures. In
330
particular, the percentage of protonated nitrogen increased from 0 to 26.16 % at pH 8
331
as the ring-opening or hydrolysis of succinimide groups could occur more easily in
332
alkaline solutions18, 35. The XPS data also showed that the atomic percentage of N
333
elements reduced to the lowest level at pH 8 (3.45 to 1.55 %) compared with the
334
cases of pH 6 (3.45 to 2.48 %) and pH 10 (3.45 to 3.19 %) (Table S1), indicating
335
that the aged PVP material could be leached or released from the membranes.
336
Previous studies denoted that the initial degradation/release of the PVP material
337
might accelerate the subsequent degradation of PES polymers and worsen the
338
enlargement of membrane pores36, 38. Actually, the amide groups (O=C-N 10)36. In the future, more detailed work need to be focused on the fouling
419
process of aged membranes as a function of operating period to aid engineers in
420
adjusting the cleaning method so that the membrane life time could be extended
421
operationally 56, 57. In addition, the combined use of 2D-CoS analysis and previously
422
reported methods, such as electrokinetic characterizations, are suggested in order to
423
obtain complementary data.
424 425 27
ACS Paragon Plus Environment
Environmental Science & Technology
426
ASSOCIATED CONTENT
427
Supporting Information
428
Table S1. Atomic fraction variations for elemental composition obtained from XPS
429
high resolution C1s, N1s, O1s, S2p and Cl2p spectra of NaOCl-aged PES/PVP
430
membranes as a function of exposure time (i.e., 1, 6, 30 days) at pH 6, 8, and 10,
431
respectively; Figure S1. XPS wide survey scans of NaOCl-aged PES/PVP
432
membranes as a function of exposure time (i.e., 1, 6, 30 days) at pH 6, 8, and 10,
433
respectively; Figure S2. XPS high resolution C1s, N1s, O1s, S2p and Cl2p spectra
434
of NaOCl-aged PES/PVP membranes as a function of exposure time (i.e., 1, 6, 30
435
days) at pH 6, 8, and 10, respectively; Figure S3. SEM images of NaOCl-aged
436
PES/PVP membranes as a function of exposure time (i.e., 1, 6, 30 days) at pH 6, 8,
437
and 10, respectively. Figure S4. Ageing process of PVP during the NaOCl exposure;
438
Figure S5. Ageing process of PES during the NaOCl exposure.
439 440 441 442
AUTHOR INFORMATION
443
Corresponding authors
444
Email:
[email protected] (Fangang MENG)
445
Notes
446
The authors declare no competing financial interest
447 448
ACKNOWLEDGEMENTS
449
This study was supported by the National Natural Science Foundation of China (No.
450
51622813 and 51608546), the Natural Science Foundation of Guangdong Province
451
(No. 2014A030306002), and the Science and Technology Planning Project of
452
Guangdong Province (No. 2015A020215014). 28
ACS Paragon Plus Environment
Page 28 of 33
Page 29 of 33
Environmental Science & Technology
453 454
References
455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494
(1) Mulder, J., Basic principles of membrane technology. Springer Science & Business Media: 2012. (2) Judd, S., The MBR book: principles and applications of membrane bioreactors for water and wastewater treatment. Elsevier: 2010. (3) Wang, Z.; Ma, J.; Tang, C. Y.; Kimura, K.; Wang, Q.; Han, X. Membrane cleaning in membrane bioreactors: a review. Journal of Membrane Science 2014, 468, 276-307. (4) Meng, F.; Zhang, S.; Oh, Y.; Zhou, Z.; Shin, H.-S.; Chae, S.-R. Fouling in membrane bioreactors: An updated review. Water Research 2017, 114, 151-180. (5) Regula, C.; Carretier, E.; Wyart, Y.; Gésan-Guiziou, G.; Vincent, A.; Boudot, D.; Moulin, P. Chemical cleaning/disinfection and ageing of organic UF membranes: a review. Water Research 2014, 56, 325-365. (6) Robinson, S.; Abdullah, S. Z.; Bérubé, P.; Le-Clech, P. Ageing of membranes for water treatment: Linking changes to performance. Journal of Membrane Science 2016, 503, 177-187. (7) Arkhangelsky, E.; Kuzmenko, D.; Gitis, V. Impact of chemical cleaning on properties and functioning of polyethersulfone membranes. Journal of Membrane Science 2007, 305, (1), 176-184. (8) Bégoin, L.; Rabiller-Baudry, M.; Chaufer, B.; Hautbois, M.-C.; Doneva, T. Ageing of PES industrial spiral-wound membranes in acid whey ultrafiltration. Desalination 2006, 192, (1-3), 25-39. (9) Gaudichet-Maurin, E.; Thominette, F. Ageing of polysulfone ultrafiltration membranes in contact with bleach solutions. Journal of Membrane Science 2006, 282, (1), 198-204. (10) Yadav, K.; Morison, K.; Staiger, M. P. Effects of hypochlorite treatment on the surface morphology and mechanical properties of polyethersulfone ultrafiltration membranes. Polymer Degradation and Stability 2009, 94, (11), 1955-1961. (11) Levitsky, I.; Duek, A.; Arkhangelsky, E.; Pinchev, D.; Kadoshian, T.; Shetrit, H.; Naim, R.; Gitis, V. Understanding the oxidative cleaning of UF membranes. Journal of Membrane Science 2011, 377, (1–2), 206-213. (12) Susanto, H.; Ulbricht, M. Characteristics, performance and stability of polyethersulfone ultrafiltration membranes prepared by phase separation method using different macromolecular additives. Journal of Membrane Science 2009, 327, (1), 125-135. (13) Zhao, C.; Xue, J.; Ran, F.; Sun, S. Modification of polyethersulfone membranes–a review of methods. Progress in Materials Science 2013, 58, (1), 76-150. (14) Ahmad, A.; Abdulkarim, A.; Ooi, B.; Ismail, S. Recent development in additives modifications of polyethersulfone membrane for flux enhancement. Chemical engineering journal 2013, 223, 246-267. (15) Idris, A.; Mat Zain, N.; Noordin, M. Y. Synthesis, characterization and performance of asymmetric polyethersulfone (PES) ultrafiltration membranes with polyethylene glycol of different molecular weights as additives. Desalination 2007, 207, (1), 324-339. (16) Kourde-Hanafi, Y.; Loulergue, P.; Szymczyk, A.; Van der Bruggen, B.; Nachtnebel, M.; Rabiller-Baudry, M.; Audic, J.-L.; Pölt, P.; Baddari, K. Influence of PVP content on degradation of PES/PVP membranes: Insights from characterization of membranes with controlled composition. Journal of Membrane Science 2017, 533, 261-269. (17) Rabiller-Baudry, M.; Leperoux, C.; Delaunay, D.; Diallo, H.; Paquin, L. Using microwaves to accelerate ageing of an ultrafiltration PES membrane by NaOCl to obtain a similar ageing state to that 29
ACS Paragon Plus Environment
Environmental Science & Technology
495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538
Page 30 of 33
for membranes working at the industrial scale. Filtration 2014, 14, (1), 38-48. (18)
Prulho,
R.;
Therias,
S.;
Rivaton,
A.;
Gardette,
J.-L.
Ageing
of
polyethersulfone/polyvinylpyrrolidone blends in contact with bleach water. Polymer Degradation and Stability 2013, 98, (6), 1164-1172. (19) Abdulla, H. A.; Minor, E. C.; Hatcher, P. G. Using two-dimensional correlations of 13C NMR and FTIR to investigate changes in the chemical composition of dissolved organic matter along an estuarine transect. Environmental science & technology 2010, 44, (21), 8044-8049. (20) Hanafi, Y.; Szymczyk, A.; Rabiller-Baudry, M.; Baddari, K. Degradation of Poly(Ether Sulfone)/Polyvinylpyrrolidone Membranes by Sodium Hypochlorite: Insight from Advanced Electrokinetic Characterizations. Environmental Science & Technology 2014, 48, (22), 13419-13426. (21) Noda, I.; Dowrey, A.; Marcott, C.; Story, G.; Ozaki, Y. Generalized two-dimensional correlation spectroscopy. Applied Spectroscopy 2000, 54, (7), 236A-248A. (22) Noda, I.; Ozaki, Y., Two-dimensional correlation spectroscopy: applications in vibrational and optical spectroscopy. John Wiley & Sons: 2005. (23) Chen, W.; Habibul, N.; Liu, X.-Y.; Sheng, G.-P.; Yu, H.-Q. FTIR and synchronous fluorescence heterospectral two-dimensional correlation analyses on the binding characteristics of copper onto dissolved organic matter. Environmental science & technology 2015, 49, (4), 2052-2058. (24) Chen, W.; Qian, C.; Liu, X.-Y.; Yu, H.-Q. Two-dimensional correlation spectroscopic analysis on the interaction between humic acids and TiO2 nanoparticles. Environmental science & technology 2014, 48, (19), 11119-11126. (25) Lee, B.-M.; Hur, J. Adsorption Behavior of Extracellular Polymeric Substances on Graphene Materials Explored by Fluorescence Spectroscopy and Two-Dimensional Fourier Transform Infrared Correlation Spectroscopy. Environmental science & technology 2016, 50, (14), 7364-7372. (26) Yu, G.-H.; Wu, M.-J.; Wei, G.-R.; Luo, Y.-H.; Ran, W.; Wang, B.-R.; Zhang, J. c.; Shen, Q.-R. Binding of organic ligands with Al (III) in dissolved organic matter from soil: implications for soil organic carbon storage. Environmental science & technology 2012, 46, (11), 6102-6109. (27) Yan, W.; Wang, H.; Jing, C. Adhesion of Shewanella oneidensis MR-1 to goethite: a two-dimensional correlation spectroscopic study. Environmental science & technology 2016, 50, (8), 4343-4349. (28) Tang, B.; Wu, P. In situ study of diffusion and interaction of water and electrolyte solution in polyacrylonitrile (PAN) membrane using FTIR and two-dimensional correlation analysis. Vibrational Spectroscopy 2009, 51, (1), 65-71. (29) Palin, A. T. Methods for the determination, in water, of free and combined available chlorine dioxide and chlorite, bromine, iodine and ozone, using diethyl-P-phenylene diamine (DPD). J. Inst. Water Eng. 1967, 21, 537-547. (30) Huang, H.; Young, T. A.; Jacangelo, J. G. Unified Membrane Fouling Index for Low Pressure Membrane Filtration of Natural Waters: Principles and Methodology. Environmental science & technology 2008, 42, (3), 714-720. (31) Kiefer, J.; Wei, G.; Ciacchi, L. C.; Lieres, E. v. Irreversible Damage of Polymer Membranes During Attenuated Total Reflection Infrared Analysis. Applied Spectroscopy 71, (6), 1127-1133. (32) Pathak, S. K.; Tripathi, S. C.; Singh, K. K.; Mahtele, A. K.; Kumar, M.; Gandhi, P. M. Removal of americium from aqueous nitrate solutions by sorption onto PC88A-Impregnated macroporous polymeric beads. Journal of Hazardous Materials 2014, 278, 464-473. (33) Regula, C.; Carretier, E.; Wyart, Y.; Sergent, M.; Gésan-Guiziou, G.; Ferry, D.; Vincent, A.; 30
ACS Paragon Plus Environment
Page 31 of 33
Environmental Science & Technology
539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582
Boudot, D.; Moulin, P. Ageing of ultrafiltration membranes in contact with sodium hypochlorite and commercial oxidant: Experimental designs as a new ageing protocol. Separation and Purification Technology 2013, 103, 119-138. (34) Vatsha, B.; Ngila, J. C.; Moutloali, R. M. Preparation of antifouling polyvinylpyrrolidone (PVP 40K) modified polyethersulfone (PES) ultrafiltration (UF) membrane for water purification. Physics and Chemistry of the Earth, Parts A/B/C 2014, 67, 125-131. (35) Wienk, I. M.; Meuleman, E. E. B.; Borneman, Z.; van den Boomgaard, T.; Smolders, C. A. Chemical treatment of membranes of a polymer blend: Mechanism of the reaction of hypochlorite with poly(vinyl pyrrolidone). Journal of Polymer Science Part A: Polymer Chemistry 1995, 33, (1), 49-54. (36) Pellegrin, B.; Prulho, R.; Rivaton, A.; Thérias, S.; Gardette, J.-L.; Gaudichet-Maurin, E.; Causserand, C. Multi-scale analysis of hypochlorite induced PES/PVP ultrafiltration membranes degradation. Journal of Membrane Science 2013, 447, 287-296. (37) Antón, E.; Álvarez, J. R.; Palacio, L.; Prádanos, P.; Hernández, A.; Pihlajamäki, A.; Luque, S. Ageing of polyethersulfone ultrafiltration membranes under long-term exposures to alkaline and acidic cleaning solutions. Chemical Engineering Science 2015, 134, 178-195. (38) Hanafi, Y.; Loulergue, P.; Ababou-Girard, S.; Meriadec, C.; Rabiller-Baudry, M.; Baddari, K.; Szymczyk, A. Electrokinetic analysis of PES/PVP membranes aged by sodium hypochlorite solutions at different pH. Journal of Membrane Science 2016, 501, 24-32. (39) Fouquet, T.; Torimura, M.; Sato, H. Multi-stage mass spectrometry of poly (vinyl pyrrolidone) and its vinyl succinimide copolymer formed upon exposure to sodium hypochlorite. Mass Spectrometry 2016, 5, (1), A0050-A0050. (40) Holst, G. The Chemistry of Bleaching and Oxidizing Agents. Chemical Reviews 1954, 54, (1), 169-194. (41)
Hassouna,
F.; Therias,
S.;
Mailhot,
G.; Gardette,
J.-L.
Photooxidation
of
poly
(N-vinylpyrrolidone)(PVP) in the solid state and in aqueous solution. Polymer Degradation and Stability 2009, 94, (12), 2257-2266. (42) Lafreniere, L. Y.; Talbot, F. D.; Matsuura, T.; Sourirajan, S. Effect of poly (vinylpyrrolidone) additive on the performance of poly (ether sulfone) ultrafiltration membranes. Industrial & engineering chemistry research 1987, 26, (11), 2385-2389. (43) MIYANO, T.; MATSUURA, T.; Sourirajan, S. Effect of polyvinylpyrrolidone additive on the pore size and the pore size distribution of polyethersulfone (Victrex) membranes. Chemical Engineering Communications 1993, 119, (1), 23-39. (44) Wu, J.; Benoit, D.; Lee, S. S.; Li, W.; Fortner, J. D. Ground State Reactions of nC60 with Free Chlorine in Water. Environmental science & technology 2015, 50, (2), 721-731. (45) Papirer, E.; Lacroix, R.; Donnet, J.-B.; Nansé, G.; Fioux, P. XPS study of the halogenation of carbon black—Part 2. Chlorination. Carbon 1995, 33, (1), 63-72. (46) Xie, P.; de Lannoy, C.-F.; Ma, J.; Wiesner, M. R. Chlorination of polyvinyl pyrrolidone– polysulfone membranes: Organic compound release, byproduct formation, and changes in membrane properties. Journal of Membrane Science 2015, 489, 28-35. (47) Rivaton, A.; Gardette, J. Photodegradation of polyethersulfone and polysulfone. Polymer Degradation and Stability 1999, 66, (3), 385-403. (48) Wolff, S. H.; Zydney, A. L. Effect of bleach on the transport characteristics of polysulfone hemodialyzers. Journal of Membrane Science 2004, 243, (1–2), 389-399. 31
ACS Paragon Plus Environment
Environmental Science & Technology
583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606
(49) Pellegrin, B.; Mezzari, F.; Hanafi, Y.; Szymczyk, A.; Remigy, J.-C.; Causserand, C. Filtration performance and pore size distribution of hypochlorite aged PES/PVP ultrafiltration membranes. Journal of Membrane Science 2015, 474, 175-186. (50) Causserand, C.; Rouaix, S.; Lafaille, J.-P.; Aimar, P. Ageing of polysulfone membranes in contact with bleach solution: Role of radical oxidation and of some dissolved metal ions. Chemical Engineering and Processing: Process Intensification 2008, 47, (1), 48-56. (51) Yadav, K.; Morison, K. R. Effects of hypochlorite exposure on flux through polyethersulphone ultrafiltration membranes. Food and Bioproducts Processing 2010, 88, (4), 419-424. (52) Xie, P.; de Lannoy, C.-F.; Ma, J.; Wang, Z.; Wang, S.; Li, J.; Wiesner, M. R. Improved chlorine tolerance of a polyvinyl pyrrolidone-polysulfone membrane enabled by carboxylated carbon nanotubes. Water Research 2016, 104, 497-506. (53) Arsuaga, J. M.; Sotto, A.; del Rosario, G.; Martínez, A.; Molina, S.; Teli, S. B.; de Abajo, J. Influence of the type, size, and distribution of metal oxide particles on the properties of nanocomposite ultrafiltration membranes. Journal of Membrane Science 2013, 428, 131-141. (54) Kim, J.; Van der Bruggen, B. The use of nanoparticles in polymeric and ceramic membrane structures: review of manufacturing procedures and performance improvement for water treatment. Environmental Pollution 2010, 158, (7), 2335-2349. (55) Pendergast, M. M.; Hoek, E. M. A review of water treatment membrane nanotechnologies. Energy & Environmental Science 2011, 4, (6), 1946-1971. (56) Fenu, A.; De Wilde, W.; Gaertner, M.; Weemaes, M.; de Gueldre, G.; Van De Steene, B. Elaborating the membrane life concept in a full scale hollow-fibers MBR. Journal of Membrane Science 2012, 421, 349-354. (57) Ayala, D. F.; Ferre, V.; Judd, S. J. Membrane life estimation in full-scale immersed membrane bioreactors. Journal of Membrane Science 2011, 378, (1), 95-100.
607 608 609 610 611 612 613 614 615 616 32
ACS Paragon Plus Environment
Page 32 of 33
Page 33 of 33
Environmental Science & Technology
617 618
Table caption
619
Table 1. 2D-CoS data on the assignment and sign of each cross-peak in synchronous (Φ)
620
and asynchronous (Ψ, in the brackets) maps of PES/PVP membranes upon exposure to
621
NaOCl at three different pHs of 6, 8 and 10 with increasing exposure time.
622 623
Figure caption
624
Figure 1.ATR-FTIR spectra (1000-1800 cm-1) of PES/PVP membranes upon exposure to
625
NaOCl at three different pHs of 6 (a), 8 (b), and 10 (c) as a function of exposure time (0-30
626
days).
627 628
Figure 2. Synchronous (a, c, e) and asynchronous (b, d, f) 2D correlation maps constructed
629
from time-dependent ATR-FTIR spectra of PES/PVP membranes in the treatment of
630
NaOCl at three different pHs of 6, 8 and 10.
631 632
Figure 3. Changes in pure water permeability (a) and membrane pore sizes (b) of PES/PVP
633
membranes exposed to NaOCl as a function of exposure time at three pHs (i.e., 6, 8 and 10).
634 635
Figure4. Filtration behavior of PES/PVP membranes exposed to NaOCl as a function of
636
exposure time at three pHs (i.e., (a) 6, (b) 8 and (c) 10) with HA solutions (10 mg-TOC/L)
637
and the vibrations of corresponding UMFI in each case (d).
638 639
Figure5. Correlations between UMFI (Hollow icons)/water permeability (Solid icons) and
640
the decrease of IR intensity of the band at 1662 cm-1 (amide groups of PVP) as a function of
641
exposure time.
33
ACS Paragon Plus Environment