Subscriber access provided by UNIV OF DURHAM
Characterization of Natural and Affected Environments
Uranium Retention in a Bioreduced Region of an Alluvial Aquifer Induced by the Influx of Dissolved Oxygen Donald Pan, Kenneth H. Williams, Mark J. Robbins, and Karrie Weber Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.8b00903 • Publication Date (Web): 11 Jul 2018 Downloaded from http://pubs.acs.org on July 12, 2018
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 38
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31
Environmental Science & Technology
Uranium Retention in a Bioreduced Region of an Alluvial Aquifer Induced by the Influx of Dissolved Oxygen Donald Pan1†, Kenneth H. Williams2, Mark Robbins2, Karrie A. Weber1,3* 1
School of Biological Sciences, University of Nebraska-Lincoln, Lincoln, NE, USA Lawrence Berkeley National Laboratory, Berkeley, CA, USA 3 Department of Earth and Atmospheric Sciences, University of Nebraska-Lincoln, Lincoln, NE, USA 2
†Present address: Department of Subsurface Geobiological Analysis and Research, Japan
Agency for Marine-Earth Science and Technology, 2-15 Natsushima-cho, Yokosuka, Kanagawa, 237-0061, Japan.
*Corresponding author Karrie A. Weber 232 Manter Hall School of Biological Sciences University of Nebraska—Lincoln Lincoln, NE 68588-0118
[email protected] phone: (402)472-2739 fax: (402)472-2083
ACS Paragon Plus Environment
Environmental Science & Technology
32 33
ABSTRACT Reduced zones in the subsurface represent biogeochemically active hotspots enriched in
34
buried organic matter and reduced metals. Within a shallow alluvial aquifer located near Rifle,
35
CO, reduced zones control the fate and transport of uranium (U). While an influx of dissolved
36
oxygen (DO) would be expected to mobilize U, we report U immobilization. Groundwater U
37
concentrations decreased following delivery of DO (21.6 mg O2/well/hr). After 23 days of DO
38
delivery, injection of oxygenated groundwater was paused and resulted in the rebound of
39
groundwater U concentrations to pre-injection levels. When DO delivery resumed (day 51)
40
groundwater U concentrations again decreased. The injection was halted on day 82 again and
41
resulted in a rebound of groundwater U concentrations. DO delivery rate was increased to 54 mg
42
O2/well/hr (day 95) whereby groundwater U concentrations increased. Planktonic cell
43
abundance remained stable throughout the experiment, but virus-to-microbial cell ratio increased
44
1.8-3.4 fold with initial DO delivery, indicative of microbial activity in response to DO injection.
45
Together these results indicate that the redox-buffering capacity of reduced sediments can
46
prevent U mobilization, but could be overcome as delivery rate or oxidant concentration
47
increases, mobilizing U.
ACS Paragon Plus Environment
Page 2 of 38
Page 3 of 38
48
Environmental Science & Technology
ABSTRACT ART
49
ACS Paragon Plus Environment
Environmental Science & Technology
50 51
INTRODUCTION Subsurface sediments are chemically and physically heterogeneous due to deposition and
52
burial of soil horizons and surface derived organic material. 1, 2 These organic-rich deposits
53
represent an important facies type of subsurface sedimentary systems that generate reduced
54
zones. The high concentrations of sediment-associated organic matter in the reduced zones
55
generate “biogeochemical hotspots” distinct from the surrounding sediment matrix 3-5 and may
56
result in diagentic retention of reduced chemical species including iron (Fe(II)) and contaminants
57
such as uranium (U(IV)). 4-6 The reduction and oxidation of uranium plays a significant role in
58
controlling uranium mobility. 5, 6 The control on uranium mobility is primarily controlled by the
59
very low solubility of solid-phase U(IV) minerals. 7 As such, biostimulation of uranium-reducing
60
bacteria was conducted to immobilize uranium in subsurface systems. 8-11
61
The stability of the immobilized uranium in these reduced regions depends on
62
maintaining the immobile, reduced state rather than forming U(VI) which is highly soluble and
63
complexes with carbonate. 12 The influx of oxidants, such as dissolved oxygen (DO) or nitrate,
64
into reduced subsurface systems threatens long-term sequestration of U as U(IV)-bearing
65
minerals by oxidizing and thus dissolving U(IV)-bearing minerals rendering U mobile in
66
groundwater. 13 While the influx of nitrate is often attributed to anthropogenic inputs, 14, 15 DO
67
infiltrates into reduced sediments through advective oxic groundwater flow as well as DO
68
intrusion and transport from the capillary fringe.16, 17 Thus, the transitions between oxic and
69
anoxic conditions can result in U geochemical changes as well as stimulation of microbial
70
activity. 18-20 Organic carbon, H2, or reduced minerals in these sediments can scavenge
71
molecular oxygen and serve as a redox buffer. 21 The redox buffering capacity in reduced
72
environments is not limited to abiotic reactions. Microbial activity has also been demonstrated
ACS Paragon Plus Environment
Page 4 of 38
Page 5 of 38
Environmental Science & Technology
73
to play a significant role in redox buffering in sedimentary environments scavenging oxidants. 22
74
The effect of an influx of oxidants on re-oxidation and remobilization of U in situ is not yet well
75
understood. However, the prevailing hypothesis describes that an influx of oxidants (such as DO
76
and nitrate) will oxidize reduced metals and radionuclides subsequently increasing mobility of
77
uranium. 23, 24
78
The influx of electron acceptors into reduced environments is recognized to stimulate
79
microbial activity. Previous column studies indicate that upon exposure to an oxidant, re-
80
oxidation of bioreduced U(IV) occurs 21, 25, 26 along with changes to microbial population
81
structures. 27, 28 With increased microbial metabolic activity, virus production has also been
82
observed to increase 29 which could further contribute to carbon flux. While the role of viruses
83
in subsurface systems is poorly understood, viruses have been described to play a significant role
84
in carbon cycling in marine and freshwater pelagic environments through the lysis of host cells
85
during the process of lytic reproduction and the subsequent release of available carbon and
86
nutrients. 30-32 Viruses have been recognized via direct counts, 33-35 metagenomic data, 36, 37
87
transcripts of viral proteins, 38 and electron microscopy 39 in shallow alluvial aquifers including
88
U contaminated environments such as the U.S. Department of Energy (DOE) Rifle field site.
89
Groundwater from organic rich regions of this aquifer also contained high viral loads, likely due
90
to the greater microbial activity expected in organic-rich sediments. 35 Given the abundance of
91
viruses in shallow alluvial aquifers, processes in the subsurface similar to those observed in
92
surface waters can further drive biogeochemical cycling in subsurface systems and subsequently
93
influence metal/radionuclide mobility. While viruses have been demonstrated to be abundant in
94
groundwater and subsurface environments, 29, 40, 41 the biogeochemical role they play in situ in
95
subsurface sedimentary environments remains poorly characterized.
ACS Paragon Plus Environment
Environmental Science & Technology
96
In an effort to investigate the effect of naturally occurring oxidant (DO) influx on the
97
stability of U in a reduced aquifer we injected oxygen-saturated groundwater into a previously
98
bioreduced experimental plot (U.S. Department of Energy (DOE) Rifle field site). The shallow
99
unconfined alluvial aquifer contains U-bearing sediments that contribute to groundwater U
100
concentrations that exceed the maximum contaminant level (MCL).42 Biostimulation of metal
101
reducers by acetate injection has been used as a U remediation strategy in the Rifle aquifer and
102
resulted in the successful removal of dissolved U from groundwater via the biogenic
103
precipitation of reduced U(IV) minerals.8-11 A byproduct of the in situ acetate injection was the
104
accumulation of biomass and the production of artificially reduced sediments, creating a
105
bioreduced zone in the aquifer.43, 44 In addition to U(IV)-bearing minerals, the bioreduced zone
106
in this aquifer contains not only reduced soluble chemical species but also reduced minerals such
107
as mackinawite (FeS) and framboidal pyrite (FeS2).5, 8 These artificially bioreduced sediments
108
share many similar characteristics as natural buried organic-rich sediment lenses such as
109
concentration of mineral U(IV) and an abundance of iron sulfide minerals. 4, 42 Thus, this
110
bioreduced zone may be indicative of biogeochemical behavior in the wider Upper Colorado
111
River Basin region where naturally reduced sediments are believed to play a major role in the
112
fate and transport of groundwater U. 42 The final acetate injection was completed a year prior to
113
the experiment described here. In this experiment groundwater collected from an upstream well
114
was sparged with air and injected back into the aquifer. The experiment lasted 123 days from
115
August 18, 2012 to December 19, 2012. During this period, the injection was repeated twice,
116
followed by an injection at an increased rate to increase the total amount of DO injected into the
117
aquifer per unit time. Each injection was separated by pauses. Groundwater geochemical changes
ACS Paragon Plus Environment
Page 6 of 38
Page 7 of 38
Environmental Science & Technology
118
were monitored over time concurrent with cell and virus abundance as an assessment of
119
microbial activity.
120 121 122
MATERIALS AND METHODS Field site. The in situ field experiment was conducted on the DOE Rifle field site located
123
480 m east of Rifle, Colorado (USA). The site hosts a shallow, unconfined alluvial aquifer
124
situated beneath a floodplain formed by a meander of the Colorado River. This aquifer is
125
composed of Holocene-age alluvium consisting of sandy gravel and gravelly sand interspersed
126
with silts and clays deposited by the river and overlying the Paleogene Wasatch Formation 9, 45,
127
which serves as a local aquitard. The bottom 3-4.6 m of the alluvial sediments are saturated, but
128
groundwater level fluctuates and can increase by as much as 1.5-1.8 m during periods of high
129
runoff. Hydraulic conductivity is estimated to be 2-10 m/day with an average alluvium porosity
130
estimated to be 15-35%. 46 The major source of groundwater in the aquifer is subsurface flow
131
and recharge from the north, flowing southwest towards the Colorado River (Fig. 1) with
132
localized spatial and temporal variations during high runoff. Additional minor contributions to
133
groundwater flow potentially come from infiltration from an on-site ditch, recharge from
134
precipitation, or hyporheic inflow of water from the Colorado River. Infiltration from the low
135
permeability Wasatch Formation is deemed insignificant. 47 The groundwater is characterized as
136
slightly reducing with DO concentrations typically less than 0.2 mg/L. 9, 46 Further details of the
137
Rifle site geology, hydrogeology and history are presented elsewhere. 8, 46
138 139
Aquifer Conditions Prior to Oxygenated Groundwater Injection. Biostimulation of the
140
indigenous metal/radionuclide reducing microbial community with acetate created a bioreduced
ACS Paragon Plus Environment
Environmental Science & Technology
141
zone consisting of immobilized U within this aquifer. Generation of the bioreduced zone was
142
accomplished through acetate injection over two successive field seasons (2010-2011; 2 and 1
143
year prior respectively) into an experimental gallery (Plot C) as described elsewhere. 48, 49 Plot C
144
is oriented 190 degrees azimuthal from north and generally oriented in the direction of
145
groundwater flow at the time of the experiments (Fig. 1). There, acetate stimulation of
146
indigenous microorganisms led to the generation of a bioreduced zone characterized by elevated
147
reduced Fe concentrations and immobilized U. 49, 50
148
Prior to the beginning of the experiment, neutral pH (7.2-7.5) groundwater was suboxic
149
in all wells (DO concentration 0.05-0.11 mg/L; ORP -132 mV – -196 mV) (Table 1) consistent
150
with prior reports of aquifer conditions.
151
elevated aqueous (filtered through 0.45 µm PTFE membrane) ferrous iron (Fe(II)) and aqueous
152
sulfide concentrations (3.4-5.1 mg/L and 9.59-63.26 µg/L, respectively), further supporting
153
suboxic conditions within the aquifer (Table 1). This was in contrast to the upgradient well
154
CU01 (unreduced region of aquifer), in which low Fe(II) and sulfide concentrations (0.27 mg/L
155
and 1.92 µg/L, respectively) were observed (Table 1). Groundwater sulfate concentrations were
156
similar amongst all wells (Table 1). Groundwater nitrate concentrations were not monitored over
157
the course of the experiment but were measured below the detection limit in ca. 80% of
158
background wells in Plot C with the highest concentration measured as 0.37 mg/L. Groundwater
159
U concentrations varied between 66 µg/L to 201 µg/L, while Mn varied between 1.02 mg/L to
160
2.11 mg/L (Table 1).
9, 46, 49, 50
Wells within the bioreduced zone contained
161 162
Oxygenated Groundwater Injection. Oxygenated groundwater injectate was prepared by
163
sparging groundwater with air until saturation with atmospheric O2 and amended with a
ACS Paragon Plus Environment
Page 8 of 38
Page 9 of 38
Environmental Science & Technology
164
conservative tracer, deuterium (as D2O; tank concentration δD=+240‰). The source of
165
groundwater originated from an unamended well (CU01) and was pumped directly into a storage
166
tank (18,000 L). Oxygenated groundwater was injected into the aquifer during three different
167
periods separated by pauses between each injection period. Each injection and pause period is
168
denoted by a numbered phase. In order to account for migration time, the phases in downgradient
169
wells are delineated by tracer concentrations at each monitoring well. As such, the corresponding
170
dates of each phase vary between wells and are indicated on each figure. During Phase 1 of the
171
experiment (days 0-23), oxygenated groundwater was injected into 6 injection wells (CG01-
172
CG06) at a rate of 36 mL/min per well in order to achieve a final DO concentration of 2-2.5
173
mg/L. The injectate was circulated between adjacent wells using a peristaltic pump. 8 During
174
Phase 2 (days 23-51), mineralization in the injectate line resulted in a decrease in the delivery of
175
oxygenated groundwater as indicated by tracer concentrations (Fig. S1). Later during Phase 3
176
(days 51-80), injection lines were checked periodically and cleaned to maintain flow rates. The
177
injectate migrated through the aquifer, passing through downgradient wells. During Phase 4
178
(days 75-95), injection halted again, with a brief injection from day 79-85. On day 85, the brief
179
injection was halted for tank re-filling and equipment maintenance. During Phase 5 (days 95-
180
125), the injection rate was increased by 2.5-fold (90 mL/min per well) in order to increase the
181
aquifer DO concentration to ca. 5-6 mg/L. Because O2 delivery was achieved by groundwater
182
injection, subsurface flow rates may have changed by 10 mL/hr during the slow injection phase
183
to 15 mL/hr during the fast injection phase. However, water table levels did not rise in
184
comparison to unamended controls (Fig. S9A). Due to a temperature differential, the injectate
185
did slightly increase groundwater temperature no more than +1°C (before day 70) and decrease
186
no more than -2°C (after day 70) (Fig. S8).
ACS Paragon Plus Environment
Environmental Science & Technology
187
Several precipitation (rain and snow) events occurred over the course of the experiment
188
with a maximum of 13 mm of precipitation recorded (Fig. S9B). Days 5, 37, 55, and 84 were the
189
only events associated with any considerable rise in the water table (Fig. S9A).
190
Actual groundwater DO concentrations were measured along with ORP in purged wells
191
using multi-parameter sondes (detection limit 0.04 mg/L, YSI, OH). The amount of O2 delivered
192
was inferred from measured concentrations of the deuterium tracer quantified using a Liquid
193
Water Isotope Analyzer (Los Gatos Research). The concentration of injected O2 inferred for
194
each well (that is the DO concentration if the injected O2 were not consumed) was calculated by
195
the ratio of D2O measured in the well to the original D2O concentration in the tank multiplied by
196
the saturation concentration of DO at the water temperature: =
197
× ,
The rate of O2 delivery into each well was determined by the following equation: =
Δ − ∆ × Δ !
198
Where is the volume of the well, and ∆ is the decrease in DO concentration due to
199
flushing. ∆ is calculated by the equation: ∆ = " # $ %& − " #
200
where ! is the first order rate of loss of the tracer determined by measuring the rate of loss of the
201
tracer during phases 2 and 4 when injectate delivery has stopped. Aqueous U concentrations in
202
downgradient wells were corrected for the soluble U delivered by injection. Injected
203
groundwater accounted for no more than 10% of sampled groundwater at its greatest extent
204
during the slow injection phase and less than 18% during the fast injection phase.
ACS Paragon Plus Environment
Page 10 of 38
Page 11 of 38
205
Environmental Science & Technology
Over the course of the experiment, groundwater samples for cation, anion, pH, and Fe(II)
206
analyses were collected from certain wells. Effects of the O2 delivery were studied in the four
207
wells (CD18, CD01, CD02, CD03) closest in proximity to where the DO influx meets the
208
bioreduced zone. These were compared to two controls: an upgradient control that had never
209
received acetate amendments (CU01) and a control that was previously biostimulated with
210
acetate but in which no O2 is delivered (CD11) (Fig. 1). Other parameters (DO, ORP,
211
temperature) were measured in situ within the wells. Samples for cell and viral enumeration
212
over the course of the experiment were also collected.
213
214
Geochemical analyses. Samples for anion, dissolved inorganic carbon (DIC), and DOC analyses
215
were filtered (0.45 µm PTFE) and stored at 4°C in no-headspace HDPE (anion) and glass vials
216
(DIC/DOC) until analysis. 51, 52 Anions were measured using ion chromatography (ICS-2100,
217
Dionex, CA) equipped with AS18 analytical columns. 53 Cations (U, Fe, Mn) were quantified
218
using inductively coupled plasma mass spectrometry (Elan DRCII ICP-MS, Perkin Elmer, Inc.)
219
following filtration (0.45 µm PTFE) and acidification (0.2 mL 12N HNO3 per 20mL sample).
220
Total cation groundwater concentrations will include submicron colloids less than 0.45 µm.
221
Ferrous iron concentrations were measured on filtered samples (0.45 µm PTFE) immediately in
222
the field upon sampling using the 1,10-Phenanthroline colorimetric method (Hach Company). 54
223
Sulfide was measured spectrophotometrically immediately upon sampling using the methylene
224
blue method (Hach Company). 55 Measurements for DIC/DOC were made on a Total Organic
225
Carbon Analyzer (TOC-VCSH; Shimadzu, Corp.). DOC was obtained as the difference between
226
total dissolved carbon and DIC. Spearman’s correlation analysis was conducted to test the
227
relationship between O2 consumed within the aquifer and change in abundance of U and other
ACS Paragon Plus Environment
Environmental Science & Technology
228
aqueous cations. All statistical computation was conducted using GraphPad Prism (v5.02,
229
GraphPad Software, Inc.). Significance level for the regressions was chosen at a P-value of
230