Validation of a Method for Extracting Microplastics from Complex

Jun 9, 2018 - Sensors that selectively detect glycolipids—molecules that are involved in infection, inflammation, and... BUSINESS CONCENTRATES ...
0 downloads 0 Views 1MB Size
Subscriber access provided by Kaohsiung Medical University

Environmental Measurements Methods

Validation of a method for extracting microplastics from complex, organic-rich, environmental matrices Rachel R Hurley, Amy L Lusher, Marianne Olsen, and Luca Nizzetto Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.8b01517 • Publication Date (Web): 09 Jun 2018 Downloaded from http://pubs.acs.org on June 9, 2018

Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.

is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.

Page 1 of 31

Environmental Science & Technology

1

Validation of a method for extracting microplastics

2

from

3

matrices

4

Rachel R. Hurley*a, Amy L. Lusher a, Marianne Olsen a, Luca Nizzetto a,b

5

a

6 7

b

complex,

organic-rich,

environmental

Norwegian Institute for Water Research (NIVA), Gaustadelléen 21, 0349 Oslo, Norway

Research Centre for Toxic Compounds in the Environment (RECETOX), Faculty of Science, Masaryk University, Kamenice 753/5, Brno 62500, Czech Republic

8 9

ABSTRACT

10

Complex and organic-rich solid substrates such as sludge and soil have been shown to be

11

contaminated by microplastics; however, methods for extracting plastic particles have not yet been

12

systemically tested or standardised. This study investigated four main protocols for the removal of

13

organic material during analysis of microplastics from complex solid matrices: oxidation using H2O2,

14

Fenton’s reagent, and alkaline digestion with NaOH and KOH. Eight common polymer types were

15

used to assess the influence of reagent exposure on particle integrity. Organic matter removal

16

efficiencies were established for test sludge and soil samples. Fenton’s reagent was identified as the

17

optimum protocol. All other methods showed signs of particle degradation or resulted in an

18

insufficient reduction in organic matter content. A further validation procedure revealed high

19

microplastic extraction efficiencies for particles with different morphologies. This confirmed the

20

suitability of Fenton’s reagent for use in conjunction with density separation for extracting

21

microplastics. This approach affords greater comparability with existing studies that utilise a density-

22

based technique. Recommendations for further method optimisation were also identified to improve

23

the recovery of microplastic from complex, organic-rich environmental samples.

ACS Paragon Plus Environment

Environmental Science & Technology

24

TOC ART

25 26 27

TEXT

28

Introduction

29

Microplastic contamination has emerged as a major global environmental issue. Small plastic particles

30

are now pervasive across marine and freshwater systems1–5. Recently, attention is beginning to focus

31

on the occurrence of microplastics within other environmental compartments6. Wastewater treatment

32

plants (WWTPs) have been shown to have a high trapping efficiency for microplastics7,8. However,

33

particles are concentrated in the solid sludge phase8,9, which is often applied to agricultural soils as

34

fertiliser. Nizzetto et al.10 estimate that between 63,000-430,000 and 44,000-300,000 tons of

35

microplastic are added per year to farmlands in Europe and North America respectively. Hence,

36

agricultural soils may represent a major environmental reservoir of microplastic. A small number of

37

studies have examined microplastics in soil11–14 and sludge samples7–9,15–21, but no standardised

38

method has emerged. The organic components, complexity of the solid matrix, and presence of

39

additional contaminants complicates the extraction of small plastic particles22. Accurately assessing

40

the magnitude of temporary stores, source inventories and emission rates of microplastics in terrestrial

41

environments is crucial for the definition of management frameworks and the protection of both

42

terrestrial and marine systems. There is an objective urgent need for validated analytical methods to

43

effectively characterise microplastic dynamics in this specific area.

ACS Paragon Plus Environment

Page 2 of 31

Page 3 of 31

Environmental Science & Technology

44

The majority of work extracting microplastics from solid matrices has been concerned with aquatic

45

sediments. Most commonly, microplastics are extracted based upon their density23–25. This can be

46

performed using density solutions or through elutriation-based methods26,27. However, this approach,

47

when used alone, is not effective for the analysis of microplastics in sewage or soil samples based on

48

the high organic matter content (up to 99%) and the presence of complex organic compounds and

49

aggregates. For example, soil organic matter (SOM) typically exhibits a density of 1.0 – 1.4 g cm-3

50

and therefore will not be effectively separated from microplastics during density extraction22. Hence,

51

additional procedural steps are required.

52

Preliminary studies that have examined small quantities of sewage sludge have bleached, dried, or

53

filtered samples prior to analysis8,9,16,17. This approach is not sufficient for analysing larger sample

54

sizes, where the organic component will likely physically conceal microplastic particles during

55

identification and quantification. More recently, studies have applied density-based separation9,17–20.

56

Some studies have incorporated an organic matter removal step19,20; however, the efficacy of these

57

techniques has not yet been systematically tested.

58

In contrast, analyses of microplastic in soil samples have, thus far, concentrated on direct extraction

59

techniques, such as pressurised liquid extraction13, thermal decomposition coupled with GC-MS11,14,

60

and rapid heat treatment28. These approaches negate the need for sample pre-treatment (i.e. the

61

isolation of microplastic particles) and yield mass-based concentrations of common polymer types.

62

However, they destroy particle information that is critical to current microplastic research directives

63

e.g. particle numbers, shapes, and size. These details are presently more important for establishing

64

potential sources or associated ecotoxicological implications than polymer concentration alone. As

65

discussed by Fuller and Gautam13, these approaches will likely complement existing methods.

66

The lack of a standardised approach to microplastic analysis has already been widely discussed24,29.

67

An important additional note is the current lack of a sufficiently detailed, unique classification scheme

68

for microplastics and related reference materials needed for the validation of methods. This is for

69

example the case for microfibers, car tire debris and other types of microplastic.

ACS Paragon Plus Environment

Environmental Science & Technology

Page 4 of 31

70

This study aims to identify an additional processing step that can be added to existing methods for

71

analysing microplastic in solid substrates (e.g. aquatic sediments). Namely, the removal of organic

72

material from soil and sludge samples will be tested. Eerkes-Medrano et al.30 highlighted several

73

considerations for methodological development: techniques should be simple, affordable, precise,

74

accurate, and have limited potential for contamination. This study will test four main protocols to

75

establish the optimal method for extracting microplastics from organic-rich environmental substrates

76

which satisfies these criteria.

77 78

Methods

79

Review of existing organic matter removal techniques

80

A commonly applied technique for removing organic material from environmental matrices is

81

oxidation using hydrogen peroxide (H2O2). Despite this, the efficacy of H2O2 has been called into

82

question. Cole et al.31 found that only 25% of biogenic material was removed following treatment

83

with 35% H2O2 at ambient temperature for 7 days. This has been observed elsewhere, where hydrogen

84

peroxide often has the effect of bleaching organic material rather than completely removing it

85

Additionally, Nuelle et al.32 noted the degradation of some polymer types as a result of H2O2

86

oxidation. These included polyethylene (PE) and polypropylene (PP), which are amongst the most

87

commonly produced plastics globally. Despite this, further studies have observed no significant

88

changes to microplastic particles following H2O2 digestion, including no evidence of microplastic

89

bleaching20,33. To reduce the reaction time, some studies have utilised higher temperatures during

90

peroxide oxidation. For example, Sujathan et al.20 used 30% H2O2 at 70°C to decrease the reaction

91

time to approximately 12 hours. Whilst 70°C is lower than the continuous operating temperatures

92

(COTs) for most of the common polymer types, the authors noted that particles composed of PMMA

93

may be affected20. A modified approach using lower temperatures may overcome this issue, although

94

the effect on reaction time must be assessed.

ACS Paragon Plus Environment

32

.

Page 5 of 31

Environmental Science & Technology

95

A potential alternative to peroxide oxidation is the use of Fenton’s reagent. This has previously been

96

used to extract microplastics from organic-rich wastewater samples34. Fenton’s reagent is an advanced

97

oxidation process using H2O2 in the presence of a catalyst (Fe2+). This method is performed at ambient

98

temperature, reducing the potential for exceeding COTs. Fenton’s reagent is effective in destroying

99

organic components such as highly chlorinated aromatic compounds or inorganic compounds, which

100

are typically recalcitrant in H2O235,36. This may prove more effective in removing all organic

101

components from complex environmental substrates. Additionally, the reaction occurs more rapidly

102

than traditional H2O2 oxidation, typically taking less than 1 hour to process wastewater samples37.

103

Ferrous sulfate (FeSO4·7H2O) is usually used as the iron catalyst component and is inexpensive and

104

readily available. Although, the composition of sewage sludge may reduce the efficacy of organic

105

matter removal; high concentrations of hydroxyl free radical scavengers, for example, will inhibit the

106

degradation of organic material38. Furthermore, the pH of the reagent must be adjusted (to 3.0 – 5.0)

107

to encourage the dissolution of the ferrous sulfate granules and optimise the degradation of organic

108

material39–41. This acidity may begin to degrade some polymers, although this effect was not observed

109

by Tagg et al.34. Therefore, the efficacy of this technique needs to be tested.

110

Other potential methods for the removal of organic matter arise from existing studies that extract

111

microplastics from biota. Acid digests, such as hydrochloric acid (HCl) and nitric acid (HNO3), have

112

been shown to be highly effective in destroying organic matter but they also attack microplastic

113

particles, leading to degradation and melting31,33,42. Hence, these have not been considered further.

114

Alkaline digests have also been investigated, including potassium hydroxide (KOH) and sodium

115

hydroxide (NaOH). Dehaut et al.42 showed that use of 10 M NaOH led to the degradation of

116

polycarbonate and polyethylene terephthalate; however, Mintenig et al.19 used NaOH digestion to

117

remove organic material from sewage sludge samples. 10% KOH at 60°C has been highlighted as the

118

optimum procedure for the extraction of microplastics from biota

119

KOH in extracting microplastics from sludge or soil must be tested. KOH breaks down humic acids;

120

however, Bläsing and Amelung22 point out that humins and alkali-insoluble compounds within soils

121

will not be removed. Humins are likely to also be present in sewage sludge in the form of raw organic

ACS Paragon Plus Environment

33,42–45

. However, the efficacy of

Environmental Science & Technology

122

matter, bacteria, and fungi that may not been removed by the wastewater treatment process46.

123

Therefore, testing of this procedure on complex environmental samples is important to establish the

124

degree of organic matter removal in this context.

125

Finally, a number of studies utilise enzymatic digestion to remove organic material prior to

126

microplastic analysis. Cole et al.31 first introduced the use of proteinase-K to extract microplastics

127

from both seawater and biota. They report a removal of >97% of biogenic material present. However,

128

this technique was applied on small sample volumes (0.2 g dry weight) and the enzyme used is

129

expensive. Hence, it may not be feasible or cost-effective to process large samples with high organic

130

content using this technique. Likely, a range of enzymes will be required to breakdown the different

131

organic compounds found in these sample types. Mintenig et al.19 apply an enzymatic-oxidative

132

procedure to extract microplastics from wastewater samples. They used protease, lipase and cellulase,

133

which are less expensive than proteinase-K. However, the procedure took over six days to complete

134

and the same study goes on to utilise a different, non-enzymatic, approach to analyse sludge samples.

135

This suggests that the technique may not be optimised for analysing solid environmental samples. For

136

these reasons, enzymatic treatments were not tested in this study.

137 138

Experimental design

139

The majority of studies that analyse microplastics in solid samples (e.g. sediments) utilise a density

140

separation procedure to isolate microplastic particles23,24. To increase potential for comparability, the

141

aim of this study was to add an additional processing step to remove organic matter in conjunction

142

with a density separation approach. Based on the review of existing literature, four main protocols

143

were tested for removal of organic material from complex, organic-rich, environmental samples.

144

Temperature and concentration variants were also tested for some of the selected reagents. As a result,

145

this study tested a total of six protocols:

146

1. 30% (v/v) H2O2. Sujathan et al.20 used this reagent at 70°C; however, the authors noted that

147

this may be above the COTs of some polymers. Microplastics have been shown to be

ACS Paragon Plus Environment

Page 6 of 31

Page 7 of 31

Environmental Science & Technology

148

preserved by other reagents during continuous heating at 60°C42. Hence, this protocol was

149

tested at two temperatures:

150

a. 30% hydrogen peroxide at 70°C

151

b. 30% hydrogen peroxide at 60°C

152

2. Fenton’s reagent. This reagent has two components: 30% (v/v) H2O2 with an iron catalyst.

153

The catalyst solution was composed of 20 g of iron (II) sulphate heptahydrate in 1 l of filtered

154

RO water. Tagg et al.34 tested this reagent within the context of extracting microplastics from

155

wastewater. The authors identified this as the optimum concentration. The catalyst solution

156

was adjusted to pH 3.0 using concentrated sulfuric acid.

157

3. NaOH solution. A 10 M solution has been applied to sludge samples by Mintenig et al.19,

158

although studies have identified some particle degradation with this concentration42. A lower

159

concentration solution may present a reduced potential for particle degradation. This

160

technique has previously been used at different concentrations to extract microplastics from

161

biota31,47,48. Hence, this protocol was tested at two concentrations to observe differences in

162

microplastic preservation and organic matter removal:

163

a. 1 M NaOH at 60°C

164

b. 10 M NaOH at 60°C

165

4. 10% KOH solution at 60°C. This protocol has been rigorously tested within the context of

166

biota microplastic studies42. The optimal operating conditions (10%, 60°C) were applied here

167

to test the efficacy of this technique in removing organic material from soils and sludge.

168

Protocol assessment was split into two main phases: 1) testing the effect of the selected protocols on

169

plastic particles; and 2) establishing the efficacy of the protocols in removing or reducing organic

170

matter content. Method validation was performed by assessing the extraction efficiency of the

171

optimum protocol. The optimum protocol was established by the outcomes of Phase 1 and 2 testing. A

172

schematic diagram showing the experimental design is provided in Figure S1.

173 174

ACS Paragon Plus Environment

Environmental Science & Technology

175

Phase 1: Effect of reagents on polymeric particles

176

The initial testing phase aimed to establish the preservation of microplastics following exposure to the

177

reagents. Eight common polymer types were tested for indicators of degradation following treatment:

178

PP, LDPE, HDPE, PS, PET, PA-66, PC, and PMMA (Table S1). These represent >70% of plastic

179

demand in Europe49. Details of the particles used are provided in Table S2 and images are presented

180

in Figure S2. The test particles were acquired through the JPI-Oceans BASEMAN project. The tested

181

particles represent large microplastics. Particles of this size were tested to improve the quality of

182

weight and mass measurements and to afford greater visibility of degradative changes to the particle

183

surface.

184

Three replicates were analysed for each of the six protocols, in addition to three control samples.

185

Three particles from each polymer type were tested in each replicate (total of 504 particles tested).

186

The particles were placed into clean, pre-washed glass jars and 30 ml of each reagent was added.

187

Filtered RO water was used in the case of the control samples. Protocols 1a, 1b, 3, 4 were placed into

188

an incubator (60 or 70°C, as detailed above; 120 rpm). The samples for Protocol 2 and the control

189

samples were performed at room temperature. The particles were exposed to the reagents for 24

190

hours. They were then removed from the jars, rinsed thoroughly in filtered RO water, and left to air

191

dry in petri dishes.

192

Microplastic particles were characterised physically prior to and following exposure. Each particle

193

was measured along the a- and b-axis using a Nikon SMZ 745T stereomicroscope at 10x

194

magnification and the Infinity Analyse software package. Particle mass was also recorded before and

195

after treatment. Each particle was photographed to assess for any visual evidence of degradation.

196

Some particles exhibited surface degradation following treatment (see Results and discussion). In this

197

case, the particles were first photographed and then gently brushed to remove loose fragments prior to

198

taking mass and size measurements.

199

Following treatment, three particles of each polymer type from each treatment were analysed using

200

FT-IR (n = 168). Particles were tested using an Agilent Cary 630 FT-IR spectrometer with a diamond

ACS Paragon Plus Environment

Page 8 of 31

Page 9 of 31

Environmental Science & Technology

201

ATR accessory. Spectral changes were noted, in addition to deviations in the library search hit quality

202

index. The library search was performed using the Agilent Polymers ATR library. Matches were

203

calculated by the MicroLab PC software which uses a scalar product algorithm to assign a hit quality

204

index. For particles exhibiting surface degradation, the fragments from the outer layer were analysed

205

separately to test for differences in the FT-IR spectra.

206 207

Phase 2: Efficacy of reagents in reducing organic matter content

208

The second phase of testing aimed to establish the proportion of organic material that is removed by

209

each of the selected protocols. For this experiment, test soil and sludge samples were collected from

210

the Oslo area. Details of sample characteristics including sampling, soil texture analysis and sludge

211

treatment are provided in the Supporting Information. Moisture content was established through the

212

percentage loss following drying at 105°C. The organic matter content of the samples was assessed

213

through loss-on-ignition (LOI): the samples were placed into a muffle furnace and heated to 550°C for

214

4 hours. The results are provided in Table S3.

215

10 g of soil and sludge were weighed into clean, pre-washed glass jars. Three replicates were

216

performed for both sample types, for each protocol (n = 36). The samples were first dried at 105°C to

217

establish the dry weight. For Protocols 1 and 2, 30 ml of H2O2 was added initially, followed by further

218

additions in 5 ml increments until no further reaction (e.g. fixing, frothing) was observed. In the case

219

of Protocol 2, the reagent was added as a ratio 1:1 H2O2 and catalyst solution. The catalyst solution

220

was added first and H2O2 was then added slowly. Further additions of the reagents were added until

221

no reaction was observed. The samples were processed at room temperature, but an ice bath was used

222

to modulate the temperature when it exceeded 40°C (Protocol 2 only). For Protocols 3 and 4, 50 ml of

223

reagent was added, with no further additions during the reaction period.

224

Following organic matter removal, the overlying liquid was decanted and vacuum-filtered onto pre-

225

weighed Whatman GF-D filter papers. The filter paper was dried and the retentate mass was

ACS Paragon Plus Environment

Environmental Science & Technology

226

established gravimetrically. The total mass loss (∆m) was assumed to directly reflect the loss of

227

organic material and this was used to estimate organic matter removal (%).

228 229

Validation: Extraction efficiency of selected protocol

230

The final phase of testing included establishing the extraction efficiency of the optimum protocol,

231

which was identified following Phase 1 and 2 testing. This aimed to assess whether the additional

232

processing step affected the recovery of particles during the full microplastic extraction procedure.

233

The test sludge and soil used in this study represent environmental samples. Three control samples of

234

sludge and soil were first tested for existing microplastic concentrations using the selected protocol.

235

Microplastic abundance in both samples was low and no particles with similar physical characteristics

236

(size, colour) were observed. The results and description of measurements are provided in the

237

Supporting Information.

238

Different microplastic shapes were used to test the influence of particle shape on extraction efficiency.

239

Thirty large PE microbeads (850-1000 µm), 30 small PE microbeads (425-500 µm), and 30 PET

240

fibres (322-395 µm) were added to each replicate. Details on the particles are provided in Table S4

241

and images are shown in Figure S3. Orange fibres (Certified reference material CRM-FOPET-1-18,

242

NIVA, Norway) were used to spike the solid samples. No orange clothing or textiles were permitted

243

near the samples during testing to prevent artificially enriching samples through airborne

244

contamination. No orange fibres were observed in ongoing laboratory contamination tests. All sample

245

processing was performed in a sterile cabinet and samples were kept covered to prevent laboratory

246

contamination. Only fibres within the predefined size range were considered, although no smaller or

247

larger orange fibres were identified.

248

For each replicate, 10 g (d.w.) of sample (sludge/soil) was added to clean, pre-washed glass jars. The

249

samples were then spiked with the microplastic particles. The particles were thoroughly mixed into

250

the solid matrix. Samples were then partially wetted using a fine spray of filtered RO water and

251

allowed to air dry. This was repeated three times to encourage the incorporation of microplastic

ACS Paragon Plus Environment

Page 10 of 31

Page 11 of 31

Environmental Science & Technology

252

particles into aggregates. This aimed to mimic environmental samples and establish environmentally-

253

relevant extraction efficiencies.

254

Organic matter removal followed the same method as outlined in Phase 1 & 2. Only the optimal

255

protocol underwent validation. Density separation was achieved using a) filtered RO water, to extract

256

microplastics at freshwater density (1 gm cm-3); and b) NaI solution (1.8 g cm-3), to extract higher

257

density microplastics. Sequential density extractions have been applied elsewhere to infer the

258

potential environmental behaviour of particles5. Containers were filled to the top with each density

259

solution, sealed, and agitated for 1 minute. The supernatant was decanted after the sample had been

260

allowed to settle for 24 hours, and vacuum filtered through Whatman GF-D filter papers. Once air-

261

dried, the filter papers were traversed at 20x magnification to count the extracted microplastics.

262

Several analytical parameters associated with density separation were tested. Firstly, the importance

263

of the ordering of the analytical procedure was investigated. Extraction efficiencies were established

264

for a) organic matter removal followed by density separation (OMR  Density); and b) density

265

separation followed by organic matter removal (Density  OMR). Three replicates were tested for

266

both approaches. For the ‘Density  OMR’ samples, the filter papers were placed into a jar after

267

density separation and subjected to organic matter removal. The samples were then filtered again, and

268

the original filter paper was carefully rinsed to ensure all particles were passed through the second

269

filter.

270

Secondly, the optimum number of density extracts was examined. Three density extracts were

271

performed for each density solution and the number of particles isolated in each was recorded.

272

Finally, the labware used for density separation was tested. Three replicates were tested in 250 ml

273

glass jars that were used in the previous phases and three additional replicates were tested using 50 ml

274

tubes. For the latter, the ‘OMR  Density’ samples were transferred to the tubes prior to density

275

separation (organic matter removal was always performed in glass labware).

276 277

ACS Paragon Plus Environment

Environmental Science & Technology

278 279 280

Results and discussion

281

Phase 1: Effect of reagents on polymeric particles

282

Physical changes

283

Different protocols to remove organic material had different effects on the physical integrity of the

284

polymers. In one replicate of Protocol 1b (30% H2O2 70°C), all three PA-66 particles were destroyed.

285

Small residual fragments were observed during filtering (Figure S4). This outlier had considerable

286

influence on the average and variance of mass and size changes observed for this treatment (Table 1).

287

The particles in the other two replicates for that treatment showed no signs of degradation. The reason

288

for such a different outcome is unexplained. PA-66 is not resistant to hydrogen peroxide at

289

concentrations ≥30%50, which causes oxidative damage and degradation of the polymer structure.

290

However, the exposure time of the three peroxide-based treatments (Protocols 1a, 1b, and 2) appears

291

to be below the time required to have an observed effect on particle mass, size, or visual appearance.

292

However, the temperature setting (70°C) used in Protocol 1b may just exceed the threshold tolerance

293

of PA-66 particles.

294

In all three replicates performed for Protocol 3b (10 M NaOH), PET and PC particles were severely

295

degraded. Surface degradation was observed for both polymer types (Figure 1bc). These visual

296

changes were also recorded as significant decreases in particle mass and size (Table 1). This effect

297

was observed to a lesser extent for Protocol 3a (1 M NaOH), with signs of ‘peeling’ (PET) and the

298

development of a matte texture (PC) (Figure S5). However, no significant change in mass or size was

299

measured. Notably, a decrease in weight of 16.1% was observed for PC following treatment with 10%

300

KOH (Protocol 4), despite no associated visual or size-related changes. Polycarbonate is significantly

301

affected by hydrolytic degradation, and alkali salt solutions such as NaOH (Protocol 3a,b) and KOH

302

(Protocol 4) accelerate this process51. Alkaline solutions also degrade PET by saponification of ester

ACS Paragon Plus Environment

Page 12 of 31

Page 13 of 31

Environmental Science & Technology

303

linkages at the particle surface52, although this was only observed for NaOH-based treatments in this

304

study.

305

For PP treated with Protocol 1b (H2O2 70°C), one particle in a single replicate was significantly

306

reduced in size and coated with an opaque white layer (Figure 1a). This degradation may have been

307

catalysed by the destruction of PA-66, which occurred in the same single replicate. All other PP

308

particles were unaffected by the Protocol 1b treatment.

309

Some limited surface degradation, noted as ‘crazing’, was observed for PS particles following

310

treatment with hydrogen peroxide (Protocols 1a and 1b) (Figure 1de). Protocol 2 (Fenton’s reagent)

311

also uses hydrogen peroxide but no degradation was observed (Figure 1f). This may be linked to the

312

influence of temperature, where more degradation was observed following Protocol 1b (70°C) than

313

Protocol 1a (60°C). Oxidation of polystyrene occurs in air when temperatures are elevated53. Protocol

314

2 was performed at temperatures