Subscriber access provided by SAM HOUSTON STATE UNIV
Environmental Measurements Methods
Gas-Phase Detection of Fluorotelomer Alcohols and Other Oxygenated PFAS by Chemical Ionization Mass Spectrometry Theran P. Riedel, Johnsie Lang, Mark J. Strynar, Andrew B. Lindstrom, and John H. Offenberg Environ. Sci. Technol. Lett., Just Accepted Manuscript • DOI: 10.1021/acs.estlett.9b00196 • Publication Date (Web): 11 Apr 2019 Downloaded from http://pubs.acs.org on April 14, 2019
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 18
Environmental Science & Technology Letters
1
Gas-Phase Detection of Fluorotelomer Alcohols and Other Oxygenated PFAS by Chemical
2
Ionization Mass Spectrometry
3 4
Theran P. Riedel1*, Johnsie R. Lang2, Mark J. Strynar1, Andrew B. Lindstrom1, John H.
5
Offenberg1
6 7
1National
8
Research Triangle Park, North Carolina, 27711, United States
9
2Oak
Exposure Research Laboratory, United States Environmental Protection Agency,
Ridge Institute for Science and Education, National Health and Environmental Effects
10
Research Laboratory, United States Environmental Protection Agency, Research Triangle Park,
11
North Carolina, 27711, United States
12 13 14
*Corresponding Author
15
Email:
[email protected] 16
Phone: 919-541-0877
ACS Paragon Plus Environment
1
Environmental Science & Technology Letters
Page 2 of 18
17
ABSTRACT
18
Per- and polyfluoroalkyl substances (PFAS) are incorporated into an ever-increasing number of
19
modern products and inevitably enter the environment and ultimately human bodies. Herein we
20
show that chemical ionization mass spectrometry with iodide reagent ion chemistry is a useful
21
technique for the detection of fluorotelomer alcohols (FTOHs) and other oxygenated PFAS,
22
including per- and polyfluoro carboxylic acids such as hexafluoropropylene oxide dimer acid. This
23
technique offers direct, high time resolution measurement capability with parts per trillion by
24
volume (ng m-3) gas-phase detection limits. Measurements were made by direct volatilization of
25
samples without prior processing, allowing for fast measurements and reduced sample treatment
26
compared to established PFAS methods. We demonstrate the utility of this technique by sampling
27
volatile and semivolatile PFAS from fluoro-additives and fluoro-products to quantify levels of
28
FTOHs and identify additional fluorinated compounds for which standards were unavailable.
29 30
INTRODUCTION
31
Per- and polyfluoroalkyl substances (PFAS) are used in a wide variety of industrial
32
applications including textile, materials, and chemical manufacturing due to beneficial mechanical
33
properties and relative inertness they can help lend to consumer and industrial products.1 Upon
34
release into the environment, these compounds are subject to slow or negligible environmental
35
degradation and are thus considered an emerging class of pollutants capable of persistent global
36
buildup and increasing human exposure.2-3
37
PFAS are believed to number in the thousands,4 without considering the likely complex
38
array of related environmental degradates. The rate with which these chemicals are produced and
39
released to environments often vastly outpaces the time required for the development of traditional
ACS Paragon Plus Environment
2
Page 3 of 18
Environmental Science & Technology Letters
40
measurement approaches that typically focus on a small subset of chemicals and occurs over
41
multiple years. As a consequence, human populations incur exposure and risk potentially for years
42
before the presence of contamination is recognized. Advances in high-resolution mass
43
spectrometry and data analytics provides a means of broadening the window of PFAS
44
identification to evaluate current occurrence rather than the multiyear lag of traditional methods.5
45
Fluorotelomer alcohols (FTOHs), perfluorinated carboxylic acids (PFCAs), and perfluoro
46
ether carboxylic acids (PFECAs) are three environmentally relevant and related classes of PFAS.
47
In this study we focus on four representative FTOHs, two PFCAs, and one PFECA: 4:2, 6:2, 8:2,
48
and 10:2 FTOH; perfluorooctanoic acid (PFOA); perfluorobutanoic acid (PFBA); and
49
hexafluoropropylene oxide dimer acid (HFPO-DA). FTOHs have been shown to be the dominant
50
PFAS measured in landfill gas, but measurements are limited to the fraction that can be collected
51
on impregnated foam disks.6 FTOHs can degrade to form certain PFCAs, which are extremely
52
stable compounds, and have been implicated to play a major role in the global dissemination of
53
PFCAs.7-9 PFOA has been linked to adverse health effects.10-11 It is often referred to as a “legacy”
54
PFAS since it has largely been phased out of industrial use over the past decade in the United
55
States and Europe but still remains environmentally relevant due to persistent levels in ground and
56
surface waters and landfills. HFPO-DA (perfluoro-2-propoxypropanoic acid) is often referred to
57
under the product name “GenX” and has received attention in states such as North Carolina where
58
PFAS manufacturing processes take place.12
59
Considering the long-chain fluorinated “tails” present on most PFAS, these compounds
60
have a considerably larger vapor pressure than equivalent hydrocarbon-based ones. For example,
61
dodecan-1-ol (C12H26O) has an equilibrium vapor pressure almost five hundred times less than that
ACS Paragon Plus Environment
3
Environmental Science & Technology Letters
Page 4 of 18
62
of 10:2 FTOH (C12F21H5O), an analogous FTOH.13-14 Thus, a significant fraction of PFAS can
63
reasonably be expected to be present in the gas phase, which is therefore a likely exposure pathway.
64
In comparison to condensed-phase measurements of PFAS, gas-phase assessments are rare,
65
largely due to the lack of established methods for reliable sample collection and quantification, but
66
such measurements are needed considering recent increases in awareness that gas-phase releases
67
may contribute significantly to overall PFAS from landfills and industrial sources. For example,
68
attempts to constrain HFPO-DA in industrial stack emissions at one facility resulted in vastly
69
different estimates of annual emissions: early estimates of 66.6 lb year-1 were adjusted to 2,758 lb
70
year-1, a 40-fold difference, when alternative methods were used.15
71
Previous publications regarding gas-phase PFAS field sampling techniques have largely
72
been limited to offline analyses of liquid-phase extracts (i.e. capture of PFAS from ambient air on
73
sorbent impregnated disks, followed by extraction and concentration for detection by gas
74
chromatography-mass spectrometry (GC-MS) and/or liquid chromatography-mass spectrometry
75
(LC-MS)).6, 16 Given the collection times, these approaches are rarely able to capture valuable
76
temporal information such as diurnal variations or emission plume intercepts which inevitably are
77
averaged and/or diluted over the entire collection period. Clearly, a real-time continuous
78
measurement technique for the detection of these compounds would be valuable.
79
In addition to field sampling, there is a need to accurately and directly quantify PFAS in
80
products like aqueous firefighting foams, industrial dispersions, and cleaners in order to better
81
constrain the contributions of such materials to the environmental PFAS burden from product
82
manufacturing and landfills. Previous publications that reported PFAS content of products used
83
extraction and cleanup steps where volatile or semivolatile PFAS could potentially be lost. For
ACS Paragon Plus Environment
4
Page 5 of 18
Environmental Science & Technology Letters
84
example, Kotthoff et al.1 reported 6:2 FTOH concentrations obtained using extractions procedures
85
that included product evaporation to dryness followed by reconstitution prior to analysis.
86
Our objective here is to demonstrate that an iodide-adduct chemical ionization mass
87
spectrometer shows potential as a reliable method for direct detection of FTOHs and other PFAS
88
that have previously been difficult to detect in the gas phase at appropriate time resolution. We
89
attempt to illustrate that utility through instrument calibrations of FTOHs, PFCAs, and a PFECA,
90
and by directly sampling semivolatile PFAS emitted from four commercially available fluoro-
91
products: three fluorosurfactants and an aqueous film-forming firefighting foam. PFAS present in
92
those products for which corresponding standards were available were quantified, and additional
93
PFAS signals were identified by probable molecular compositions.
94 95
MATERIALS AND METHODS
96
Chemical Ionization Mass Spectrometry. A high-resolution time-of-flight chemical
97
ionization mass spectrometer (ToF-CIMS, Aerodyne Research Inc/TOFWERK AG) operated in
98
negative ion mode with iodide reagent ion chemistry was used for this study (see Table S1 and
99
Figure S1 for instrument details). This technique has been used previously to quantify inorganic
100
and polar organic atmospheric trace gases and offers online, direct, and fast measurements without
101
the need for lengthy collection, extraction, and/or derivatization prior to detection.17-19 Sample air
102
is drawn directly into the inlet where analyte species are ionized by forming molecular adducts
103
with the iodide reagent ion, a soft ionization process that typically preserves parent ions with little
104
fragmentation. Analyte ion detection occurs at the parent + iodide mass-to-charge ratio (m/Q), and
105
all signals were normalized to the total reagent ion signal (I- + I(H2O)-) and reported per million
106
counts per second (cps) of total reagent ion. As in other studies utilizing an iodide-adduct CIMS,
ACS Paragon Plus Environment
5
Environmental Science & Technology Letters
Page 6 of 18
107
the ion optics were tuned to maximize both the total ion current and the ratio of the iodide-water
108
cluster to iodide (I(H2O)-/I-).17 The latter was used as an indication of the collision-induced
109
molecular ion declustering potential, which we hoped to minimize thereby preserving parent ions.
110
Air containing the gas-phase analytes was sampled directly into the instrument at 2.1 L
111
min-1. Though the CIMS is capable of faster data acquisition (>1 Hz), full mass spectra (3 – 1132
112
Da) measured at 0.33 Hz were sufficient for the investigations presented here. Preliminary proof-
113
of-concept tests in which the CIMS sampled the headspace above neat FTOH, per-, and polyfluoro
114
carboxylic acid standards indicated that the instrument effectively detected these classes of
115
compounds, and that the volatility was such that they were present in significant gas-phase
116
quantities. Instrument calibrations were then performed on 4:2, 6:2, 8:2, and 10:2 FTOH; PFOA;
117
PFBA; and HFPO-DA. During calibrations, dilute solutions of the standards were prepared in ethyl
118
acetate with concentrations ranging from 1 – 18 ng µL-1, depending on the standard. During
119
calibrations, 1 – 10 µL of standard solution was injected onto a 47 mm diameter, 2.0 µm pore size
120
polytetrafluoroethylene (PTFE) filter (Pall Corporation) within a perfluoroalkoxy (PFA) polymer
121
filter holder (Savillex) placed immediately upstream of the CIMS inlet. Humidified clean air (50%
122
RH) was used as the dilution/carrier gas. Upon contact with the filter, analytes were continuously
123
volatilized into the CIMS, and signals were integrated until