Subscriber access provided by UNIV OF CAMBRIDGE
Article
Removal of Ozone by Carbon Nanotubes / Quartz Fiber Film Shen Yang, Jingqi Nie, Fei Wei, and Xudong Yang Environ. Sci. Technol., Just Accepted Manuscript • DOI: 10.1021/acs.est.6b02563 • Publication Date (Web): 08 Aug 2016 Downloaded from http://pubs.acs.org on August 14, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Environmental Science & Technology is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 25
Environmental Science & Technology
1
Manuscript for Environmental Science & Technology
2
Removal of Ozone by Carbon Nanotubes / Quartz Fiber Film
3
Shen Yang, † Jingqi Nie, ‡ Fei Wei, ‡ Xudong Yang *, †
4
†
Department of Building Science, Tsinghua University, Beijing 100084, PR China
5
‡
Department of Chemical Engineering, Tsinghua University, Beijing 100084, PR
6
China
7
*
8
Tsinghua University, Beijing 100084, PR China. Telephone: (86)10- 62788845. Fax:
9
(86)10-62773461. E-mail:
[email protected] 10
Address correspondence to Dr. Xudong Yang, Department of Building Science,
Notes: The authors declare no competing financial interest.
1
ACS Paragon Plus Environment
Environmental Science & Technology
11
ABSTRACT
12
Ozone is recognized as a harmful gaseous pollutant, which can lead to severe human
13
health problems. In this study, carbon nanotubes (CNTs) were tested as a new
14
approach for ozone removal. The CNTs/quartz fiber film was fabricated through
15
growth of CNTs upon pure quartz fiber using chemical vapor deposition method.
16
Ozone conversion efficiency of the CNTs/quartz fiber film was tested for 10 h and
17
compared with that of quartz film, activated carbon (AC), and a potassium iodide (KI)
18
solution under the same conditions. The pressure resistance of these materials under
19
different airflow rates was also measured. The results showed that the CNTs/quartz
20
fiber film had better ozone conversion efficiency but also higher pressure resistance
21
than AC and the KI solution of the same weight. The ozone removal performance of
22
the CNTs/quartz fiber film was comparable with AC at 20 times more weight. The
23
CNTs played a dominant role in ozone removal by the CNTs/quartz fiber film. Its high
24
ozone conversion efficiency, light-weight and free-standing properties make the
25
CNTs/quartz fiber film applicable to ozone removal. Further investigation should be
26
focused on reducing pressure resistance and studying the CNT mechanism for
27
removing ozone.
28
Keywords: Ozone removal; Carbon nanotubes; Quartz fiber
2
ACS Paragon Plus Environment
Page 2 of 25
Page 3 of 25
Environmental Science & Technology
29
GRAPHIC ABSTRACT
30
3
ACS Paragon Plus Environment
Environmental Science & Technology
31
INTRODUCTION
32
Ozone is a regulated gaseous pollutant in both atmospheric and indoor environments.
33
It can have adverse effects on human health, for example, exposure to ozone is closely
34
related to asthma and respiratory symptoms such as coughing and upper airway
35
irritation.1-3 Significant associations have been reported between outdoor ozone
36
concentrations and both mortality and morbidity.4, 5 Indoor ozone may originate from
37
ozone emission sources indoors and ventilation or infiltration from outdoors.
38
Generally, indoor ozone concentrations are lower than outdoors due to removal by
39
indoor surfaces and indoor gas phase reactions. However, even low concentrations of
40
ozone can still lead to human health problems.6 The standard value of
41
one-hour-average ozone concentration indoor is around 80 ppb in China.7 The limiting
42
level of ozone in aircraft cabins is higher, 250 ppb, since the outside ozone
43
concentration of aircraft cabins is much higher than that of buildings.8 As a result of
44
humans spending most of their time in indoor environments, it is estimated that 25-60%
45
of total daily inhalation intake of ozone comes from indoors.9 Moreover, indoor
46
ozone-initiated chemistry can generate secondary emissions of fine and ultrafine
47
particles and volatile organic compounds (VOCs),10-12 which may be more harmful
48
than ozone itself.13 Therefore, it is necessary to remove ozone from indoor
49
environments.
50
Several methods have been developed to remove ozone. Activated carbon (AC) is
51
well known for its large adsorptive capacity due to its high surface area and porous
52
structure. A number of studies have investigated interactions between ozone and AC,
53
indicating that AC is effective at removing ozone.14-17 According to long-term
54
performance tests, AC can provide substantial and long-lasting ozone control.18, 19 The 4
ACS Paragon Plus Environment
Page 4 of 25
Page 5 of 25
Environmental Science & Technology
55
capability of ozone removal by AC may be attributable to the ozone’s reaction with
56
oxide groups on the surface of the AC20, 21 and the catalytic action of AC for ozone
57
decomposition.22-24 In terms of catalytic decomposition of ozone, the catalytic
58
materials are usually noble metals and metal oxide, which are often supported on
59
materials such as TiO2, SiO2, and AC. 25-27 Potassium iodide (KI) solution and wet KI
60
is also used to remove indoor ozone, especially in sampling procedures as passive or
61
active ozone scrubbers.
62
wheat board, and sunflower board, are applied as passive ozone removal
63
mechanisms.30 Though the methods mentioned above have been proven to remove
64
ozone in most indoor conditions, it is of interest to investigate new approaches for
65
potential improved ozone removal.
66
Carbon nanotubes (CNTs) have been applied in many fields since their discovery31
67
due to their superior properties, such as high electrical conductivity,32 mechanical
68
stability,33 and thermal conductivity.34 In recent years, this material has been
69
introduced to the field of air filtration. CNTs have several advantages compared to
70
traditional filters, including chemical stability and resistance of high temperatures.
71
Previous studies have proven that CNTs and CNT-coated films can filter particles35
72
and adsorb volatile organic vapors effectively.36, 37 As for interaction with ozone,
73
several studies analyzed ozone adsorption on CNTs from micro-perspectives38-40 and
74
focused on electrical properties of ozonized CNTs.41-43 However, one question yet to
75
be addressed is how CNTs perform as filters for removing ozone? Furthermore, how
76
do they compare with other ozone cleaners, such as AC and KI solutions?
77
This study aims to investigate the active ozone removal performance of CNTs and
78
conduct a comparative analysis with conventional ozone scrubbers. In this study, the
28, 29
Additionally, green building materials, e.g., bamboo,
5
ACS Paragon Plus Environment
Environmental Science & Technology
79
CNTs/quartz fiber film was fabricated through growth of CNTs upon pure quartz film
80
using chemical vapor deposition method. Ozone conversion efficiency of the
81
CNTs/quartz fiber film was tested for 10 h and compared with that of quartz fiber
82
(QF), AC, and KI solutions under the same conditions. The pressure resistance of
83
CNTs/QF film, pure QF, and AC under different airflow rates were measured and
84
compared as well.
85
MATERIALS AND METHODS
86
Fabrication of Materials
87
The CNTs/QF film was fabricated through in-situ growth of CNTs upon QF using
88
floating catalyst chemical vapor deposition method. Figure 1 shows the manufacturing
89
device. Ferrocene (purity > 99.99%, Tianjin Damao Chemical Reagent Factory,
90
China), acting as the catalyst, was put in a quartz tube (38 mm inner diameter, 180
91
mm length) at the entrance side of the heater (TF55030C-1, Thermal scientific, USA).
92
After heating, the ferrocene slowly evaporated and the gaseous ferrocene was adhered
93
onto the pure QF (50 mm in diameter, Membrane Solutions Inc.) and placed in the
94
middle of the quartz tube. With the protection of 600 mL/min argon and 100 mL/min
95
hydrogen, the temperature inside the quartz tube was increased to and maintained at
96
760 °C. Next, ethylene flowed at 200 mL/min as the carbon source for the CNT
97
growth on the catalyzed quartz film for 40 min. Afterward, the heater was turned off.
98
The flow of ethylene was also switched off, while argon and hydrogen continued
99
flowing until the temperature inside the quartz tube decreased to room temperature.
100
The CNTs/QF film was finally obtained. The weight of the film was 0.30 ± 0.01g,
101
measured by an electrical scale (HZT-A1000, Hz & Huazhi, USA.).
102
Granular AC (Getu, Yunjia Company, China) was selected from 20 mesh to 40 mesh 6
ACS Paragon Plus Environment
Page 6 of 25
Page 7 of 25
Environmental Science & Technology
103
and divided into two parts. The first one (AC-1) was 0.30 ± 0.01 g, of the same weight
104
as the CNTs/QF film. The second one (AC-2) was 6.00 ± 0.01 g, 20 times as heavy as
105
AC-1. These two samples were packaged in circular, nonwoven fabric (40 mm in
106
diameter) separately. Note that due to a small quantity of granular AC, the circular,
107
nonwoven fabric of AC-1 was not fully filled in the cross-sectional area. Hence,
108
airflow would bypass the granular AC in ozone removal by AC-1. In addition, 0.30 ±
109
0.01g AC (AC-3) was prepared in free form to fully fill a smaller cross-sectional area
110
as mentioned hereinafter. Furthermore, 0.30 ± 0.01 g KI was dissolved in 5.7 mL of
111
deionized water to make a KI solution of 5% mass concentration.
112
Measurement of Physical Properties
113
The Brunauer–Emmett–Teller (BET) specific surface areas (SBET) of QF, CNTs/QF
114
film, and AC were determined using a Quadra Sorb Station (Quantachrome
115
Instruments Corp., Florida, USA) through nitrogen adsorption-desorption method.
116
Additionally, to determine the proportion of CNTs in the CNTs/QF film,
117
thermogravimetric analysis (TGA) measurements were conducted for the QF and the
118
CNTs/QF film. With a mixed flow of 50 mL/min oxygen and 20 mL/min nitrogen, the
119
tests were carried out on a thermogravimetric analyzer instrument (TGA Q500) at a
120
scan rate of 20 °C/min from 30 to 900 °C. Then the CNT content of the CNTs/QF film
121
was calculated by Equation (1): CNTs % =
122
LWCNTs /QF − LWQF 1 − LWQF
× 100% .
(1)
123
Where, LWCNTs/QF is the weight loss percentage of the CNTs/QF film at 900 °C, and
124
LWQF is the weight loss percentage of the QF at 900 °C.
125
Experimental Setting
126
Figure 2 shows the schematic of the experimental system for ozone conversion tests. 7
ACS Paragon Plus Environment
Environmental Science & Technology
Page 8 of 25
127
A 53 L stainless environmental chamber, equipped with a water bath for controlling
128
temperatures in the chamber at 25 ± 0.5 °C, was used to provide a controllable
129
environment for conversion tests. The material was held in the reactor, which was put
130
inside the chamber. A 500 mL glass bottle with a temperature and humidity monitor
131
inside, called a pre-heater, was placed in the upstream of the reactor to ensure that the
132
temperature of the air passing through the reactor was identical to that inside the
133
chamber. On the night before each experiment, the system was supplied with clean air
134
via a synthetic air cylinder (20.9% oxygen and rest of nitrogen, Beijing Zhaoge Gas
135
Technology, qualified by Tsinghua University, China) at 2.60 L/min, controlled by a
136
pressure-reducing valve and flow controller. Before entering into the reactor, the clean
137
air went through a humidity controller, to control relative humidity (RH) at 10 ± 5%,
138
and a thin glass tube under an ultra-violet (UV) lamp, to generate ozone. The
139
consistency of ozone generation is shown in Supporting Information. The ozone
140
monitor (Model 205, 2B Technology, USA, precision of 1 ppb or ± 1%, whichever is
141
greater) was placed at the outlet of the reactor to measure exhaust ozone concentration
142
every one minute until the end of the experiment. The ozone monitor was zeroed and
143
calibrated after every set of experiments. Note that all the steps mentioned above were
144
conducted while wearing disposable gloves to avoid any contamination of lipids from
145
the experimenter’s hands. In the experiment, the exhaust ozone concentration of the
146
empty reactor was controlled at around 300 ppb, which could be regarded as the net
147
inlet ozone concentration during the experiment. The ozone conversion efficiency, η,
148
was calculated according to equation (2): η = (1
149 150
Cout ) × 100 % Cin .
(2)
Where, Cin is the net inlet ozone concentration, ppb, and Cout is the exhaust ozone 8
ACS Paragon Plus Environment
Page 9 of 25
Environmental Science & Technology
151
concentration, ppb. By error analysis, a 2% error was estimated when obtaining the
152
ozone conversion efficiency.
153
There were three different reactors used in experiments, shown in Figure 2: a) a
154
stainless fixture (38 mm inner diameter, Merk Millipore), b) a glass gas-washing
155
bottle, and c) a thin, stainless, hollow tube (8mm inner diameter, 250mm length). The
156
stainless fixture was for QF, CNTs/QF film, AC-1 (0.30 g), and AC-2 (6.00 g), while
157
the stainless, hollow tube was for AC-3 so that the granules could fully fill the
158
cross-sectional area. The difference of ozone conversion performance between QF
159
and CNTs/QF film can demonstrate the effect of CNTs, while that between CNTs/QF
160
film and AC-1, AC-2, and AC-3 can illustrate comparisons of the two materials. The
161
glass gas-washing bottle was used for the 5% KI solution.
162
A differential gage (P3000T, BESTACE, USA) was connected at the ends of the
163
reactor to measure pressure resistance of QF, CNTs/QF film, and AC-2, under
164
different airflow rates, varying from 0.5 L/min to 5.0 L/min linearly.
165
RESULTS
166
Characterization of Materials
167
The appearance of manufactured CNTs/QF film is shown in Figure 3 a), compared
168
with that of pure QF shown in b). The most obvious change of the QF film after
169
loading CNTs was that it turned black in color due to being coated with black visible
170
CNTs. Through the TGA measurement mentioned above and calculated by Equation
171
(1), the CNT content of the CNTs/QF film was 13.4%.
172
The physical properties of measured materials are listed in Table 1. After loading the
173
CNTs, the SBET of CNTs/QF film increased more than 10 times, while the weight and 9
ACS Paragon Plus Environment
Environmental Science & Technology
174
the thickness only grew 0.05 g and 0.09 mm, respectively. The CNTs greatly
175
improved the adsorption capacity of pure QF. The SBET of the AC was more than 20
176
times larger than that of CNTs/QF film. Moreover, AC-2 was 10 times as thick as the
177
CNTs/QF film. In comparing the shapes of CNTs/QF film with granular AC and KI
178
solution, the free-standing properties (acting as a filter itself without any containers to
179
hold) of CNTs/QF film exhibited an advantage in active ozone removal.
180
Ozone Conversion Efficiency of Materials
181
The ozone conversion efficiency of different materials is shown in Figure 4. The
182
CNTs/QF film demonstrated very high ozone conversion efficiency: over 96% during
183
the 10 h-long experiment, with a slight downtrend starting at the 6th hour. In
184
comparison, the subtract material, which was the pure QF, performed the worst with
185
efficiency perceptibly reduced from over 40% to less than 10%. This indicated that
186
CNTs play a dominant role in ozone removal by the CNTs/QF film. The ozone
187
removal effect of AC-1 was far inferior to that of the CNTs/QF film, decreasing from
188
60% to approximately 40%. Since the granule could not fully fill the cross-sectional
189
area of the 40 mm diameter nonwoven fabric of AC-1, some ozone bypassed the AC
190
granules, resulting in low ozone conversion efficiency. Even though airflow with
191
ozone passed the AC granules thoroughly for AC-3, the ozone conversion efficiency
192
of AC was still inferior to that of the CNTs/QF film of the same weight, resulting in
193
an approximate 10% shortage, shown in Figure 5. As for the 5% KI solution, it
194
functioned well at the beginning, but the efficiency dropped sharply at the 6th hour
195
once the reactive I- in the solution was depleted. When comparing these materials
196
using the same weight, the CNTs/quartz film performed the best, both in ozone
197
conversion efficiency and persistency. As for AC-2, increasing the weight of AC by
198
nearly 20 times (0.6 g) and fully filling the package, a noticeable improvement in 10
ACS Paragon Plus Environment
Page 10 of 25
Page 11 of 25
Environmental Science & Technology
199
ozone removal was exhibited. Under these circumstances, AC-2 maintained ozone
200
conversion efficiency at around 98% and showed no appreciable downtrend. The
201
ozone removal performance of the CNTs/QF film and AC-2 was roughly the same in
202
the first eight hours. However, since the downtrend of the CNTs/QF was witnessed, it
203
is reasonable to presume that the disparity between the CNTs/QF and AC-2 may
204
increase in continuing experiments.
205
Pressure Resistance of Materials
206
The pressure drops over different flow rates for the three materials are shown in
207
Figure 6. Noticeably, pressure resistance increased with the increase of airflow rates
208
and indicated an obvious linear relationship for all three materials. The pressure drop
209
of the CNTs/QF film was the largest, followed by the pure QF. The substrate pure QF
210
contributed about 1/3 of the total pressure drop. The pressure resistance of AC-2 was
211
only 1/8 of that of the pure QF. From the perspective of pressure resistance during
212
filtration, AC performed the best.
213
DISCUSSION
214
Comparison between CNTs/QF Film and Conventional Ozone Removal Materials
215
The experimental results above have demonstrated that the ozone removal
216
performance of the CNTs/QF film was better than conventional materials, i.e., AC and
217
KI solutions of the same weight, and even comparable with AC at 20 times the weight
218
from the perspective of ozone conversion efficiency. Since the tested materials had
219
different shapes and properties, it was difficult to guarantee all the test conditions for
220
different materials were the same exactly. In this study, the mass of materials, the air
221
flowrate and inlet ozone concentration were controlled at the same for different
222
materials. The average contact time of ozone-AC-3 and ozone-CNTs/QF film was 11
ACS Paragon Plus Environment
Environmental Science & Technology
223
0.007s and 0.012s, respectively. The slightly longer contact time of ozone-CNTs/QF
224
film may contribute to better ozone conversion of CNTs/QF film to some extent, but
225
not the key point, seen from the supplementary experiment in Supporting Information.
226
As shown in Table 1, the SBET of AC in this study was far larger than that of the
227
CNTs/QF film. Why is it that the CNTs/QF performed better? Since the SBET was
228
measured using the nitrogen adsorption-desorption method, there are two possible
229
explanations for the phenomena according to our understanding: 1) chemisorption of
230
ozone on CNTs was much stronger than that on AC; and 2) There were special
231
connection bonds between the CNTs and ozone rather than the nitrogen. Besides, high
232
pressure resistance of the CNTs/QF film comparing with AC and pure QF indicated
233
that the flow paths inside the filter were more narrow and tortuous. It increased the
234
possibility of ozone encountering inner surfaces of the filter, which in turn increased
235
the ozone conversion efficiency. Though pressure resistance of the pure QF was much
236
higher than the AC, the ozone removal performance of the pure QF was much worse.
237
It indicated that the high ozone conversion efficiency of the CNTs/QF film may
238
attribute to both CNTs and its microstructures. These hypotheses will be verified in
239
our future studies.
240
The experimental condition of 300 ppb ozone concentration and 10% RH set in this
241
study was in accordance with the environmental condition in ozone-polluted aircraft
242
cabins.44 For building environment, the ozone concentration to deal with is lower even
243
for outdoor ozone
244
ozone conversion efficiency of the CNTs/QF film was tested under lower inlet ozone
245
concentration and showed good performance, as given in the Supporting Information.
246
Due to competitive adsorption of water vapor on the CNTs/QF film, it is presumed
247
that ozone conversion efficiency of the CNTs/QF film may decrease when RH
45
and the RH is usually higher. In our preliminary experiment,
12
ACS Paragon Plus Environment
Page 12 of 25
Page 13 of 25
Environmental Science & Technology
248
increases, but still higher than that of the AC under same conditions. Since activated
249
carbon usually contains oxygen functions while function-free CNTs do not, the
250
activated carbon may be more hydrophilic than CNTs. Therefore, the adverse
251
influence of water vapor on ozone adsorption may be larger to AC than the CNTs/QF
252
film. However, hydrophilicity of the CNTs/QF film may increase with time, since the
253
ozone and water vapor mixture can introduce some oxygen functions onto CNTs 46.
254
High ozone conversion efficiency along with light-weight and free-standing properties
255
enable the application of CNTs/QF film for ozone removal. However, the material’s
256
high-pressure resistance could be a barrier since it leads to more power for driving air.
257
The substrate, QF, did not remove ozone effectively itself, but contributed almost 1/3
258
of the total pressure drop. Thus, more efforts could be made on the substrate to
259
improve its performance. For example, carbon fiber is more incompact and could,
260
adsorb ozone itself. Another possible approach is to reduce the CNTs’ growth time so
261
that the relative content of CNTs can be smaller. Further investigation should be
262
focused on reducing pressure resistance. Additionally, the downtrend of ozone
263
conversion efficiency of the CNTs/QF film at the 6th hour may arouse concerns on
264
sustainable usage and lifespan of the filter. It may owe to that more and more
265
adsorption sites on the CNTs/QF film were occupied by ozone, the ability of
266
removing ozone thus decreased. The lifespan and regeneration of the CNTs/QF film
267
removing ozone will be discussed in our upcoming studies.
268
Advantages of a Two-stage Structure of the CNTs/QF Film
269
Now that it is known that the subtract, QF, of the CNTs/QF film did not contribute to
270
effective ozone removal but considerable pressure resistance, the idea of cutting QF
271
off the CNTs/QF film is reasonable. To realize this idea, an additional experiment was 13
ACS Paragon Plus Environment
Environmental Science & Technology
272
conducted. A free-standing pure CNTs film weighing 0.02 g was fabricated according
273
to the literature.47 Ozone conversion efficiency and pressure resistance of the CNTs
274
film was measured and compared with that of the CNTs/QF film, shown in Figure 7.
275
To test the ozone removal of the CNTs/QF film under extreme high ozone level
276
conditions and to tell the performance difference between the two materials better, the
277
net inlet ozone concentration was elevated to 2.33 ppm, and other settings were
278
implemented consistent with the method mentioned above.
279
As seen in Figure 7, ozone conversion efficiency of the CNTs/QF film became lower
280
when the net inlet concentration increased, which can be owing to more adsorption
281
sites were occupied by ozone and the occupation was faster. Ozone conversion
282
efficiency of the CNTs film dropped sharply and displayed an obvious gap with that
283
of the CNTs/QF film at the beginning. This indicates that the ozone performance of
284
the pure CNTs film was inferior to that of the CNTs/QF film. A possible reason is that
285
the thickness of the CNTs film (scale of 1 µm) was much smaller than the CNTs/QF
286
film. Furthermore, the pressure resistance of the CNTs film was about 25% higher,
287
which may be attributed to its compact structure due to CNTs gathering with liquid
288
bridge force. In addition, the mechanical strength of the pure CNTs film was poorer
289
than that of the CNTs/QF film. The pure CNTs film can be easily broken under
290
conditions of high airflow passing velocity. Hence, in the comparison between pure
291
CNTs film and the two-stage structure of the CNTs/QF film, the latter provided better
292
ozone removal, lower pressure resistance, and stronger free-standing ability.
293
ACKNOWLEDGEMENTS
294
This study was supported by the National Basic Research Program of China (The 973
295
Program) through Grant No. 2012CB720100, and the Innovative Research Groups of 14
ACS Paragon Plus Environment
Page 14 of 25
Page 15 of 25
Environmental Science & Technology
296
the National Natural Science Foundation of China grant No. 51521005.
297
Supporting Information Available
298
Details of ozone generation (Section S1), the CNTs/QF film removing ozone under
299
lower ozone level condition (Section S2) and the supplementary experiment for AC-3
300
(Section S3) are provided, including three figures to show results. This information is
301
available free of charge via the Internet at http://pubs.acs.org.
302
REFERENCES
303
1.
304
concentration and the incidence of asthma in nonsmoking adults: the AHSMOG Study.
305
Environ. Res. 1999, 80, (2), 110-121.
306
2.
307
Med. 2001, 35, (4), 214-222.
308
3.
309
W. S.; Leaderer, B. P., Association of low-level ozone and fine particles with
310
respiratory symptoms in children with asthma. JAMA 2003, 290, (14), 1859-67.
311
4.
312
mortality - Analysis and meta-analysis. Epidemiology 2005, 16, (4), 446-457.
313
5.
314
ozone and mortality with comparison to the national morbidity, mortality, and air
315
pollution study. Epidemiology 2005, 16, (4), 436-445.
316
6.
317
Volume I of III; EPA 600/R-05/004aF; U.S. EPA, National Center for Environmental
318
Assessment: Arlington, VA, 2006.
319
7.
Mcdonnell, W.; Abbey, D., N; Lebowitz, M., Long-term ambient ozone
Carlisle, A.; Sharp, N., Exercise and outdoor ambient air pollution. Br. J. Sports
Gent, J. F.; Triche, E. W.; Holford, T. R.; Kathleen, B.; Bracken, M. B.; Beckett,
Ito, K.; De Leon, S. F.; Lippmann, M., Associations between ozone and daily
Bell, M. L.; Dominici, F.; Samet, J. M., A meta-analysis of time-series studies of
U.S. EPA. Air Quality Criteria for Ozone and Related Photochemical Oxidants.
Indoor Air Quality Standard; GB/T18883-2002; Beijing: Administration of 15
ACS Paragon Plus Environment
Environmental Science & Technology
Page 16 of 25
320
Quality Supervision, Inspection and Quarantine, 2000 (in Chinese).
321
8.
322
Aviation Administration of China, 2011 (in Chinese).
323
9.
324
exposures to ozone and products of ozone-initiated chemistry. Environ. Health
325
Perspect. 2006, 114, (10), 1489-1496.
326
10. Fadeyi, M. O., Mass balance modeling of building recirculation rates and
327
filtration efficiencies effects on secondary organic aerosols derived from
328
ozone-initiated chemistry. Build. Simul. 2013, 7, (2), 165-173.
329
11. Guan, J.; Gao, K.; Wang, C.; Yang, X.; Lin, C.-H.; Lu, C.; Gao, P., Measurements
330
of volatile organic compounds in aircraft cabins Part I: Methodology and detected
331
VOC species in 107 commercial flights. Build. Environ. 2014, 72, 154-161.
332
12. Gao, K.; Xie, J.; Yang, X., Estimation of the contribution of human skin and
333
ozone reaction to volatile organic compounds (VOC) concentration in aircraft cabins.
334
Build. Environ. 2015, 94, 12-20.
335
13. Weschler, C. J., New Directions: Ozone-initiated reaction products indoors may
336
be more harmful than ozone itself. Atmos. Environ. 2004, 38, (33), 5715-5716.
337
14. Rakit-skaya,
338
decomposition of ozone by fibrous carbon. Russ. J. Appl. Chem. 1994, 66, (9),
339
2141-2144.
340
15. Deitz, V.; Bitner, J., Interaction of ozone with adsorbent charcoals. Carbon 1973,
341
11, (4), 393-401.
342
16. Ondarts, M.; Outin, J.; Reinert, L.; Gonze, E.; Duclaux, L., Removal of ozone by
343
activated carbons modified by oxidation treatments. Eur. Phys. J. Spec. Top. 2015,
344
224, (9), 1995-1999.
Transport Aircraft Airworthiness Standards; CCAR-25-R4; Beijing: Civil
Weschler, C. J., Ozone’s impact on public health: Contributions from indoor
T.;
Bandurko,
A.
Y.;
Litvinskaya,
16
ACS Paragon Plus Environment
V.,
Low-temperature
Page 17 of 25
Environmental Science & Technology
345
17. Gall, E. T.; Corsi, R. L.; Siegel, J. A., Impact of physical properties on ozone
346
removal by several porous materials. Environ. Sci. Technol. 2014, 48, (7), 3682-90.
347
18. Shields, H. C.; Weschler, C. J.; Naik, D., Ozone removal by charcoal filters after
348
continuous extensive use (5 to 8 years). Indoor Air 1999, 99, 49-54.
349
19. Cros, C. J.; Morrison, G. C.; Siegel, J. A.; Corsi, R. L., Long-term performance of
350
passive materials for removal of ozone from indoor air. Indoor Air 2012, 22, (1),
351
43-53.
352
20. Dusenbury, J.; Cannon, F., Advanced oxidant reactivity pertaining to granular
353
activated carbon beds for air pollution control. Carbon 1996, 34, (12), 1577-1589.
354
21. Takeuchi, Y.; Itoh, T., Removal of ozone from air by activated carbon treatment.
355
Sep. Technol. 1993, 3, (3), 168-175.
356
22. Whinnery, L.; Coutts, D.; Adams, R.; Shen, C.; Quintana, C.; Showalter, S.
357
Microporous carbon filters as catalysts for ozone decomposition; Sandia National
358
Labs., Livermore, CA (United States): 1995.
359
23. Álvarez, P. M.; Masa, F. J.; Jaramillo, J.; Beltran, F. J.; Gómez-Serrano, V.,
360
Kinetics of ozone decomposition by granular activated carbon. Ind. Eng. Chem. Res.
361
2008, 47, (8), 2545-2553.
362
24. Subrahmanyam, C.; Bulushev, D. A.; Kiwi-Minsker, L., Dynamic behaviour of
363
activated carbon catalysts during ozone decomposition at room temperature. Appl.
364
Catal. B-Environ. 2005, 61, (1-2), 98-106.
365
25. Heisig, C.; Zhang, W.; Oyama, S. T., Decomposition of ozone using
366
carbon-supported metal oxide catalysts. Appl. Catal. B-Environ. 1997, 14, (1),
367
117-129.
368
26. Yu, Q.; Pan, H.; Zhao, M.; Liu, Z.; Wang, J.; Chen, Y.; Gong, M., Influence of
369
calcination temperature on the performance of Pd–Mn/SiO 2–Al 2 O 3 catalysts for 17
ACS Paragon Plus Environment
Environmental Science & Technology
370
ozone decomposition. J. Hazard. Mater. 2009, 172, (2), 631-634.
371
27. Nikolov, P.; Genov, K.; Konova, P.; Milenova, K.; Batakliev, T.; Georgiev, V.;
372
Kumar, N.; Sarker, D. K.; Pishev, D.; Rakovsky, S., Ozone decomposition on Ag/SiO
373
2 and Ag/clinoptilolite catalysts at ambient temperature. J. Hazard. Mater. 2010, 184,
374
(1), 16-19.
375
28. Williams, E. L.; Grosjean, D., Removal of atmospheric oxidants with annular
376
denuders. Environ. Sci. Technol. 1990, 24, (6), 811-814.
377
29. Yang, S.; Gao, K.; Yang, X., Volatile organic compounds (VOCs) formation due
378
to interactions between ozone and skin-oiled clothing: Measurements by
379
extraction-analysis-reaction method. Build. Environ. 2016, 103, 146-154.
380
30. Hoang, C. P.; Kinney, K. A.; Corsi, R. L., Ozone removal by green building
381
materials. Build. Environ. 2009, 44, (8), 1627-1633.
382
31. Iijima, S., Helical microtubules of graphitic carbon. Nature 1991, 354, (6348),
383
56-58.
384
32. Ebbesen, T.; Lezec, H.; Hiura, H.; Bennett, J.; Ghaemi, H.; Thio, T., Electrical
385
conductivity of individual carbon nanotubes. Nature 1996, 382, 54-56.
386
33. Gao, G.; Cagin, T.; Goddard III, W. A., Energetics, structure, mechanical and
387
vibrational properties of single-walled carbon nanotubes. Nanotechnology 1998, 9, (3),
388
184.
389
34. Akoshima, M.; Hata, K.; Futaba, D. N.; Mizuno, K.; Baba, T.; Yumura, M.,
390
Thermal diffusivity of single-walled carbon nanotube forest measured by laser flash
391
method. Jpn. J. Appl. Phys. 2009, 48, (5), 05EC07.
392
35. Li, P.; Wang, C.; Zhang, Y.; Wei, F., Air filtration in the free molecular flow
393
regime: a review of high-efficiency particulate air filters based on carbon nanotubes.
394
Small 2014, 10, (22), 4543-61. 18
ACS Paragon Plus Environment
Page 18 of 25
Page 19 of 25
Environmental Science & Technology
395
36. Shih, Y.-h.; Li, M.-s., Adsorption of selected volatile organic vapors on multiwall
396
carbon nanotubes. J. Hazard. Mater. 2008, 154, (1), 21-28.
397
37. Pan, B.; Xing, B., Adsorption mechanisms of organic chemicals on carbon
398
nanotubes. Environ. Sci. Technol. 2008, 42, (24), 9005-9013.
399
38. Yim, W. L.; Liu, Z. F., A reexamination of the chemisorption and desorption of
400
ozone on the exterior of a (5,5) single-walled carbon nanotube. Chem. Phys. Lett.
401
2004, 398, (4-6), 297-303.
402
39. Akdim, B.; Kar, T.; Duan, X.; Pachter, R., Density functional theory calculations
403
of ozone adsorption on sidewall single-wall carbon nanotubes with Stone-Wales
404
defects. Chem. Phys. Lett. 2007, 445, (4-6), 281-287.
405
40. Khorrampour, R.; Esrafili, M. D.; Hadipour, N. L., Density functional theory
406
study of atomic oxygen, O2 and O3 adsorptions on the H-capped (5,0) single-walled
407
carbon nanotube. Phys. E: Low-Dimens. Syst. Nanostruct. 2009, 41, (8), 1373-1378.
408
41. Picozzi, S.; Santucci, S.; Lozzi, L.; Cantalini, C.; Baratto, C.; Sberveglieri, G.;
409
Armentano, I.; Kenny, J. M.; Valentini, L.; Delley, B., Ozone adsorption on carbon
410
nanotubes: Ab initio calculations and experiments. J. Vac. Sci. Technol. A 2004, 22,
411
(4), 1466.
412
42. Wongwiriyapan, W.; Honda, S.-i.; Konishi, H.; Mizuta, T.; Ikuno, T.; Ohmori, T.;
413
Ito, T.; Shimazaki, R.; Maekawa, T.; Suzuki, K.; Ishikawa, H.; Oura, K.; Katayama,
414
M., Ultrasensitive ozone detection using single-walled carbon nanotube networks. Jpn.
415
J. Appl. Phys. 2006, 45, (4B), 3669-3671.
416
43. Iijima, T.; Inagaki, Y.; Oshima, H.; Iwata, T.; Sato, R.; Kalita, G.; Kuzumaki, T.;
417
Hayashi, Y.; Tanemura, M., Structural and electrical properties of ozone irradiated
418
carbon nanotube yarns and sheets. Mater. Express 2012, 2, (4), 357-362.
419
44. Bhangar, S.; Cowlin, S. C.; Singer, B. C.; Sextro, R. G.; Nazaroff, W. W., Ozone 19
ACS Paragon Plus Environment
Environmental Science & Technology
420
levels in passenger cabins of commercial aircraft on North American and transoceanic
421
routes. Environ. Sci. Technol. 2008, 42, (11), 3938-3943.
422
45. Zhang, Q.; Yuan, B.; Shao, M.; Wang, X.; Lu, S.; Lu, K.; Wang, M.; Chen, L.;
423
Chang, C.-C.; Liu, S. C., Variations of ground-level O3 and its precursors in Beijing
424
in summertime between 2005 and 2011. Atmos. Chem. Phys. 2014, 14, 6089–6101.
425
46. Peng, K.; Liu, L. Q.; Li, H.; Meyer, H.; Zhang, Z., Room temperature
426
functionalization of carbon nanotubes using an ozone/water vapor mixture. Carbon
427
2011, 49, (1), 70-76.
428
47. Viswanathan, G.; Kane, D. B.; Lipowicz, P. J., High efficiency fine particulate
429
filtration using carbon nanotube coatings. Adv. Mater. 2004, 16, (22), 2045-2049.
20
ACS Paragon Plus Environment
Page 20 of 25
Page 21 of 25
Environmental Science & Technology
Tables Table 1. Physical characterization of measured materials BET specific Thickness Materials
Weight (g)
Shape
surface area
(mm) (m2/g) QF
0.25
0.37
Free-standing film
3.37
CNTs/QF film
0.30
0.46
Free-standing film
42.84
AC-1
0.30
--*
Granule packaged in 913.20 nonwoven fabric Granule packaged in AC-2
4.60**
6.00
913.20 nonwoven fabric Granule piled up
AC-3
5.70***
0.30
913.20 inside the reactor
5% KI
6.00 (with --
solution *
Liquid
--
0.30g KI)
The AC granule could not fully-fill the cross-sectional area of 40 mm diameter
nonwoven fabric. Hence, the thickness of AC-1 was not measured. **
Average thickness when placed horizontally.
***
Average thickness after full-filling cross area of the thin, stainless, hollow tube.
21
ACS Paragon Plus Environment
Environmental Science & Technology
Figures
Figure 1. Schematic of manufacturing device for CNTs/QF film.
Figure 2. Experimental system for ozone conversion tests. The reactors used in the experiments included, a) a stainless fixture, b) a glass gas-washing bottle, and c) a thin, stainless, hollow tube.
22
ACS Paragon Plus Environment
Page 22 of 25
Page 23 of 25
Environmental Science & Technology
a)
b)
Figure 3. Appearance of a) the CNTs/QF film and b) the pure QF.
Figure 4. Ozone conversion efficiency of different materials. Note that the graduations of Y-axis are not consistent for efficiency greater and less than 90%.
23
ACS Paragon Plus Environment
Environmental Science & Technology
Figure 5. Comparison of ozone conversion efficiency between AC-3 and the CNTs/QF film.
Figure 6. Pressure drops over different flow rates for three materials.
24
ACS Paragon Plus Environment
Page 24 of 25
Page 25 of 25
Environmental Science & Technology
Figure 7. Ozone conversion efficiency and pressure resistance of the CNTs/QF film and CNTs film. Lines with dots represent pressure drops, while smooth curves represent ozone conversion efficiency.
25