Subscriber access provided by Olson Library | Northern Michigan University
Article
Stereoselective Analysis and Dissipation of Propiconazole in Wheat, Grapes, and Soil by Supercritical Fluid Chromatography Tandem Mass Spectrometry Youpu Cheng, Yongquan Zheng, Fengshou Dong, Jing Li, Yaofang Zhang, Shuhong Sun, Ning Li, Xin-Yi Cui, Yuanhong Wang, Xinglu Pan, and Weilong Zhang J. Agric. Food Chem., Just Accepted Manuscript • DOI: 10.1021/acs.jafc.6b04623 • Publication Date (Web): 16 Dec 2016 Downloaded from http://pubs.acs.org on December 19, 2016
Just Accepted “Just Accepted” manuscripts have been peer-reviewed and accepted for publication. They are posted online prior to technical editing, formatting for publication and author proofing. The American Chemical Society provides “Just Accepted” as a free service to the research community to expedite the dissemination of scientific material as soon as possible after acceptance. “Just Accepted” manuscripts appear in full in PDF format accompanied by an HTML abstract. “Just Accepted” manuscripts have been fully peer reviewed, but should not be considered the official version of record. They are accessible to all readers and citable by the Digital Object Identifier (DOI®). “Just Accepted” is an optional service offered to authors. Therefore, the “Just Accepted” Web site may not include all articles that will be published in the journal. After a manuscript is technically edited and formatted, it will be removed from the “Just Accepted” Web site and published as an ASAP article. Note that technical editing may introduce minor changes to the manuscript text and/or graphics which could affect content, and all legal disclaimers and ethical guidelines that apply to the journal pertain. ACS cannot be held responsible for errors or consequences arising from the use of information contained in these “Just Accepted” manuscripts.
Journal of Agricultural and Food Chemistry is published by the American Chemical Society. 1155 Sixteenth Street N.W., Washington, DC 20036 Published by American Chemical Society. Copyright © American Chemical Society. However, no copyright claim is made to original U.S. Government works, or works produced by employees of any Commonwealth realm Crown government in the course of their duties.
Page 1 of 40
Journal of Agricultural and Food Chemistry
1
Stereoselective Analysis and Dissipation of Propiconazole in Wheat, Grape s, and
2
Soil by Supercritical Fluid Chromatography Tandem Mass Spectrometry
3
Youpu Cheng,*,‡ Yongquan Zheng,*,† Fengshou Dong,† Jing Li,§ Yaofang Zhang,‡
4
Shuhong Sun,‡ Ning Li,‡ Xinyi Cui,‡ Yuanhong Wang,‡ Xinglu Pan,† and
5
Weilong Zhang‡
6 7 8 9
†
State Key Laboratory for Biology of Plant Diseases and Insect Pests, Institute of
Plant Protection, Chinese Academy of Agricultural Sciences, Beijing, China ffi
Tianjin Agricultural University, Tianjin, China
§
Institute of Quality Standard and Testing Technology for Agro-products, Tianjin
10
Academy of Agricultural Sciences, Tianjin, China
11
* Corresponding author (Tel: +86-22-23781301; Fax: +86-22-23781315; E-mail:
12
[email protected])
13
-1ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
14
ABSTRACT: An efficient and sensitive chiral analytical method was established for
15
the determination of propiconazole stereoisomers by supercritical fluid
16
chromatography/tandem mass spectrometry (SFC-MS/MS). Stereoisomeric separation
17
was performed on a Chiralpak AD-3 column with CO2/ethanol (93:7) as the mobile
18
phase. The four propiconazole stereoisomers were well separated in 4.7 min with
19
resolutions above 2.0. The specificity, linearity, matrix effects, accuracy, precision,
20
and stability of the developed method were evaluated. The stereoselective dissipation
21
of propiconazole in wheat straw, grape, and soil samples was investigated by the
22
proposed method. The results indicated that significant stereoselective degradation
23
occurred in wheat straw and grapes, with preferential degradation of (-)-propiconazole
24
A and (+)-propiconazole B in wheat straw and the opposite case in grapes. No
25
enantioselectivity was observed in soil, although diastereoisomer A degraded faster
26
than diastereoisomer B. These results could contribute to a more accurate assessment
27
of the environmental risk and food safety of propiconazole.
28
KEYWORDS: propiconazole, stereoselective analysis, SFC-MS/MS, wheat, grapes
29
-2ACS Paragon Plus Environment
Page 2 of 40
Page 3 of 40
Journal of Agricultural and Food Chemistry
30
INTRODUCTION
31
Propiconazole
32
(cis-trans-1-[[2-(2,4-dichlorophenyl)-4-propyl-1,3-dioxolan-2-yl]methyl]-1H-1,2,4-tri
33
azole) is a broad-spectrum systemic triazole fungicide with prominent protective and
34
curative properties. This fungicide has been widely used to control powdery mildew,
35
rusts, and leaf spot on wheat, grapes, turf and hardwoods, among others.1 However,
36
this compound is associated with a higher incidence of liver tumors (benign and
37
malignant) in long-term fed male mice,2, 3 and the U.S. EPA has identified it as a
38
possible human carcinogen.4
39
Propiconazole has two asymmetrically substituted C atoms and thus exists as two
40
pairs of enantiomers. The four stereoisomers are separated into cis [(2R, 4S) and (2S,
41
4R)], 1 and 2, and trans [(2R, 4R) and (2S, 4S)], 3 and 4, configurations (Figure 1).5
42
Similar to most chiral pesticides, propiconazole has been produced and used to date in
43
the form of a mixture of the four stereoisomers. Commonly, the enantiomers of the
44
same chiral compound have identical physicochemical properties and abiotic
45
degradation rates.6, 7 However, a large difference may be exhibited between their
46
individual bioactivities, toxicities, or metabolism when the stereoisomers are exposed
47
to asymmetric chemical or biological systems, and the dissipation or bioaccumulation
48
of the stereoisomers in organisms or the environment is often stereoselective.8, 9 Thus,
49
the data from conventional analyses that have treated stereoisomers as one compound
50
are incomplete and nonspecific. It is essential to study stereoselectivity of a chiral
51
pesticide in plants and the environment to accurately evaluate food safety and -3ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
52
environmental risk.10 For propiconazole, the biological activity of each stereoisomer
53
was shown to vary with pathogens.11 Stereoisomers with absolute configuration 2S
54
were more efficient inhibitors of ergosterol biosynthesis in Ustilago maydis than the
55
corresponding 2R stereoisomers. In many cases, the fungicidal activity of
56
cis-propiconazole was more efficient than that of trans-propiconazole.12, 13 Although
57
the bioactivity of each propiconazole stereoisomer differs, few studies have examined
58
their fates individually under field conditions possibly due to the lack of effective
59
chiral analytical methods.
60
In our previous study, an analytical method for the stereoisomeric separation and
61
determination of propiconazole by normal phase HPLC with UV detection was
62
established.14 However, this method requires a long analysis time and a large amount
63
of organic solvent. Furthermore, because of an inability to remove certain endogenous
64
interferences and the lack of high selectivity for UV detection, it was challenging to
65
apply the methodology to some complex matrices, such as wheat. Mass spectrometric
66
detection, with its advantages of high selectivity, high sensitivity, and simple sample
67
pretreatment, has become the first choice in many laboratories.15 A study using
68
reversed-phase HPLC-MS/MS revealed that the four propiconazole stereoisomers
69
could be separated on a Lux Cellulose-2 column, but the retention time was too long
70
(greater than 50 min) to be suitable for routine analysis.16 Another study attempted to
71
separate propiconazole stereoisomers using HPLC-MS/MS on an AGP column, but
72
the resolutions among the eluted peaks of propiconazole under optimal conditions
73
were only 0.8, 0.6, and 1.2.17 In recent years, supercritical fluid chromatography -4ACS Paragon Plus Environment
Page 4 of 40
Page 5 of 40
Journal of Agricultural and Food Chemistry
74
(SFC), which possesses the advantages of speed, efficient separation and
75
environmental friendliness, has received increasing attention in chiral separation. 18
76
Toribio et al.19 successfully separated propiconazole stereoisomers using SFC with a
77
diode-array detector. Nevertheless, simultaneous determination of propiconazole
78
stereoisomers in wheat, grapes and soil by SFC has not been reported to date.
79
SFC-MS/MS is an effective alternative technique that overcomes many of the
80
shortcomings inherent to current methods.20 It combines the advantages of SFC with
81
HPLC-MS/MS technology. In addition, the use of post-column polar solvent
82
compensation technology has greatly improved the sensitivity of this technique.21
83
The objective of this work was to develop and validate an SFC-MS/MS method for
84
the determination of propiconazole stereoisomers in plants and soil and apply the
85
proposed method to study the stereoselective behavior of propiconazole in wheat
86
straw, grapes, and soil. The results will not only improve our understanding of chiral
87
pesticides but also provide data for the rational production and use of chiral
88
pesticides.
89
MATERIALS AND METHODS
90
Reagents and Materials. A propiconazole stereoisomer mix standard (purity:
91
96.5%), with the ratio of the four stereoisomers shown in Figure 2A close to 2:2:3:3,
92
was purchased from China Standard Material Center (Beijing, China). The
93
commercial 20% propiconazole micro-emulsion was obtained from the Langfang
94
pesticide pilot plant (Langfang, China). Four stereoisomers of propiconazole with
95
purity≥99.9% were prepared by Chiralway Biotech Co., Ltd. (Shanghai, China). -5ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
96
Chromatography-grade acetonitrile, methanol, ethanol, 2-propanol, and formic acid
97
were purchased from Honeywell International (Morris Plains, NJ). Ultra-pure water
98
was obtained from a Milli-Q water purification system (Bedford, MA). Analytic grade
99
anhydrous magnesium sulfate, sodium chloride, and acetonitrile were from Sinopharm
100
Chemical Reagent Beijing Company (Beijing, China). Primary secondary amine
101
(PSA, 40 μm), octadecylsilane (C18, 40 μm), graphitized carbon black (GCB, 40 μm)
102
sorbents, and Cleanert Pesti-Carb/PSA (500 mg/500 mg/6 mL) SPE cartridges were
103
purchased from Agela Technologies, Inc. (Tianjin, China). Liquid CO2, Ar and N2
104
with purity over 99.999% were acquired from Qianxi Jingcheng Gas Sales Center
105
(Beijing, China).
106
A standard stock solution of the propiconazole stereoisomer mix (1000 mg/L) was
107
prepared in chromatography-grade acetonitrile. The pure solvent solutions required
108
for standard curves (10-1000 μg/L propiconazole mix) were prepared in acetonitrile
109
from the stock solution by serial dilution. All solutions were protected against light
110
with aluminum foil and stored at -20 °C prior to use.
111
Field Experiments. Working areas for wheat and grape were prepared in
112
experimental fields at Tianjin Agricultural University (Tianjin, China) in 2015. The
113
fields were divided into 30 m2-sized blocks, and a 1-m buffer zone was established to
114
separate each plot. Four trial plots were prepared for each treatment, of which three
115
plots were used as replicates, and the fourth one was used as the control. No plots had
116
been treated with the targeted fungicide in the preceding five years, and the use of any
117
other fungicide with a similar structure to that of propiconazole was forbidden during -6ACS Paragon Plus Environment
Page 6 of 40
Page 7 of 40
Journal of Agricultural and Food Chemistry
118
the trial period. The temperature of the area was maintained in the range of 26±10 °C
119
throughout the experiment. The propiconazole commercial product (20%
120
micro-emulsion) dissolved in water was sprayed one time on each plot. The
121
application rate was 180 g a.i./ha (grams of active ingredient per hectare, 1.5 times the
122
recommended dose, hereinafter the same) for the plots of wheat and wheat soil and 90
123
g a.i./ha for the grape plots. The foliar treatment was conducted on wheat and grape
124
plants at growth stages 2.7 and 7.5, respectively (according to the BBCH scale, i.e. the
125
Biologische Bundesanstalt, Bundessortenamt and Chemische Industrie scale).
126
Representative wheat straw (including straw and leaves) and grape samples for the
127
dissipation study were collected from each plot on day 0 (2 h), 1, 3, 5, 7, 10, 14, 21,
128
28, and 35 after spraying; wheat grain samples were collected at harvest on day 50
129
after treatment. Soil samples were collected at depths of 0-15 cm at 15 randomly
130
selected points. The soil was sandy loam with 1.86% organic matter and pH 8.57
131
(suspension of soil in 0.01 M CaCl 2, 1:2.5 w/w). All samples were separately minced
132
(for wheat straw), mixed and stored at -20 °C.
133
Instrumentation and SFC-MS/MS Analytical Conditions. Stereoselective
134
analysis of propiconazole stereoisomers was performed using an Acquity ultra
135
performance convergence chromatography system (Waters, Milford, MA), which
136
included an auto back pressure regulator (ABPR), a sample manager, a binary solvent
137
manager, a column manager, a Waters 515 compensation pump and a PDA detector.
138
The optical rotation of the propiconazole stereoisomers was measured using an
139
OR-2090 Plus detector (JASCO Corporation, Japan). A Chiralpak AD-3 chiral -7ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
140
column (150 mm×4.6 mm i.d., 3 μm particle size, Daicel Chemical Industries, Japan)
141
was used for the resolution of analytes. The chiral stationary phase of the column was
142
amylose tris-(3,5-dimethylphenyl-carbamate) coated on 3-μm silica gel. The mobile
143
phase, consisting of CO2 and ethanol at a ratio of 93:7, was pumped at a flow rate of
144
2.0 mL/min during the analysis process. The ABPR pressure, column oven
145
temperature and sample room temperature were set at 2200 psi, 30 °C, and 25 °C,
146
respectively. In each run, 2 μL analyte samples were injected and 0.1% formic
147
acid/methanol (v/v), as a post-column compensation additive, was pumped at a flow
148
rate of 0.1 mL/min. Under the above conditions, the four propiconazole stereoisomers
149
were eluted within 4.7 min.
150
Quantitative analysis of the propiconazole stereoisomers was performed using a
151
triple quadrupole Xevo-TQD mass spectrometer (Waters Corp.) equipped with an
152
electrospray ionization (ESI) source. The nebulizer gas was 99.999% N 2, and the
153
collision gas was 99.999% Ar with a pressure of 2×10 -3 mbar in the T-wave cell. The
154
optimal monitoring conditions for target compounds were as follows: the capillary
155
voltage, source temperature and desolvation temperature were 3.0 kV, 150 °C and
156
500 °C, respectively, and a 50 L/h cone gas flow and 900 L/h desolvation gas flow
157
were applied. ESI+ and multiple reaction monitoring mode were adopted. The cone
158
voltage was 43 V, m/z 342 was selected as the precursor ion, and m/z 69 and m/z
159
158.9 were set as the product quantitative and qualitative ions, respectively, with the
160
corresponding collision energy settings at 22 and 28 V. The dwell time was 197 ms.
-8ACS Paragon Plus Environment
Page 8 of 40
Page 9 of 40
Journal of Agricultural and Food Chemistry
161
Masslynx NT v.4.1 SCN 882 (Waters Corp.) software was used to collect and analyze
162
the data.
163
Sample Preparation. Samples of wheat straw, wheat grain, and grapes were
164
thoroughly homogenized using a food processor. Soils were air-dried at room
165
temperature and passed through a 2-mm sieve.
166
An aliquot of homogenized sample of 5 g of wheat straw, 10 g of wheat grain, 10 g
167
of grape or 10 g of soil was weighed into a 50-mL PTFE centrifuge tube with screw
168
cap. For the recovery study, appropriate volumes of the propiconazole stereoisomer
169
mix standard solution were added. Blank samples were treated similarly to the other
170
samples, but no standard solution was added. Then, the tubes were vortexed for 3 min
171
and kept at room temperature for 2h. Next, 5 mL of ultra-pure water was added to
172
each matrix, except for grape, to which no water was added. Next, 10 mL of
173
acetonitrile was added. The tubes were capped and vortexed for 3 min, ensuring the
174
solvent interacted thoroughly with the sample, and then 4 g of anhydrous magnesium
175
sulfate and 1 g of sodium chloride were added to each tube. After the tubes were
176
capped, they were immediately vortexed intensively for 1 min and centrifuged for 5
177
min at a relative centrifugal force (RCF) of 2811×g. Then, a portion of supernatant
178
was transferred for further clean-up procedures.
179
For the wheat straw, wheat grain, and soil samples, 1.5 mL of the upper layer
180
(acetonitrile) was transferred into a 2-mL single-use centrifuge tube containing 150
181
mg of anhydrous magnesium sulfate and a fixed amount of sorbent (50 mg PSA+40
182
mg GCB for wheat straw and 50 mg PSA for wheat grain or soil). The tubes were -9ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
183
capped, vortexed again for 1 min and centrifuged for 5 min at 2811×g RCF. The
184
obtained supernatants were filtered through a 0.22-μm nylon syringe for SFC-MS/MS
185
injection.
186
For the grape sample, 2 mL of the supernatant acetonitrile was transferred to a
187
Cleanert Pesti-Carb/PSA SPE cartridge, which was preconditioned by 2×5 mL of
188
elution solvent (acetonitrile/toluene, 3:1, v/v). After that, the target compound was
189
eluted by 2×3 mL of elution solvent. All eluates were collected and evaporated to
190
dryness at 40 °C. The extract was reconstituted in 2 mL of acetonitrile and filtered
191
through a 0.22-μm syringe filter for SFC-MS/MS analysis.
192
Method Validation. Five blank samples of each matrix (wheat straw, wheat grain,
193
grape and soil) were analyzed to verify the absence of interfering species surrounding
194
the retention time of each stereoisomer. The linearity of the method was determined
195
by linear regression analysis of both the standard solution and matrix-matched
196
calibration curves. Parameters of the linear regression equations, including slope,
197
intercept and the correlation coefficient (R2), were calculated. The matrix-dependent
198
LOD and LOQ of the method were determined using the blank and calibration
199
standards of wheat straw, wheat grain, grape, and soil. The LOD for each
200
propiconazole stereoisomer is the concentration that produces a signal-to-noise (S/N)
201
ratio of 3, whereas the LOQ is defined based on S/N=10, estimated from the
202
chromatogram corresponding to the lowest concentration of the matrix-matched
203
calibration.
204
The matrix effect (ME, %) was calculated by - 10 ACS Paragon Plus Environment
Page 10 of 40
Page 11 of 40
Journal of Agricultural and Food Chemistry
Sin matrix - Sin solvent ×100% Sin solvent
205
ME =
206
where S denotes the slope of the calibration curves.
207
The accuracy and precision of the method were investigated by performing
Eqn. 1
208
recovery assays. Five replicates of samples spiked with the propiconazole
209
stereoisomer mix at three concentration levels (0.01, 0.05, and 0.5 mg/kg for wheat
210
grain, grape and soil and 0.02, 0.05, and 0.5 mg/kg for wheat straw) were prepared on
211
three different days by different operators. Analytes were extracted and purified
212
according to the procedure mentioned above. The precision for repeatability and
213
reproducibility was expressed as the intra-day and inter-day relative standard
214
deviation (RSD).
215
The stability of propiconazole in the solvent and matrices was tested monthly by
216
injection of a newly prepared working solution. All of the samples used in the stability
217
test were stored at -20 °C.
218
Data Analysis. The separation parameters of the propiconazole stereoisomers,
219
including retention factor (k'), selectivity factor (α) and resolution (Rs), were
220
calculated as follows
221 222
t t0 t0 k2 α k1
k'
Eqn. 2 Eqn. 3 t 2 t1 w1 w1
223
Rs 1.177
224
where t was the retention time, t0 was the void time under the above mentioned
225
conditions (determined using 1,3,5-tri-tert-butylbenzene), and w was the peak at half
226
height.
Eqn. 4
- 11 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
227
Page 12 of 40
The degradation of the propiconazole stereoisomers in plants and soil was assumed
228
to accord with first-order kinetics. The corresponding degradation rate constant, k, and
229
the half-life (T1/2, day) were calculated by
230
C C0 e - kt
Eqn. 5
231
T1 / 2 ln 2 /k 0.693/k
Eqn. 6
232
where C0 denotes the initial concentration and C denotes the concentration at
233
sampling time t. Regression functions were obtained on the basis of the mean value of
234
three replicates.
235
The enantiomer fraction (EF) was used to measure the enantioselectivity of the
236
dissipation of the propiconazole enantiomers, and the diastereoisomer fraction (DF)
237
was calculated to fully describe the stereoselectivity of dissipation. The EF and the
238
DF of the propiconazole stereoisomers were defined by 22, 23
239
EFA
( ) A ( ) A ( ) A
Eqn. 7
240
EFA
( ) B ( ) B ( ) B
Eqn. 8
241
DF =
Da Da + Db
242
where (+)A, (−)A, (+)B, and (−)B denote the peak areas of the four specified
Eqn. 9
243
stereoisomers and Da and Db denote the peak areas of diastereoisomers A and B of
244
propiconazole, respectively.
245
RESULTS AND DISCUSSION
246
Optimization of Chromatographic Conditions. Screening the chiral stationary
247
phase (CSP). Four polysaccharide-based CSPs, Chiralpak AD-3, Chiralpak IA-3,
248
Chiralpak IB-3, and Chiralpak IC-3, were employed to examine their ability to - 12 ACS Paragon Plus Environment
Page 13 of 40
Journal of Agricultural and Food Chemistry
249
discriminate propiconazole stereoisomers. The screening assays were performed using
250
different organic solvents of acetonitrile, methanol, ethanol, and 2-propanol as
251
modifiers. Typical SFC-MS/MS chromatograms and the related separation conditions
252
are presented in Figure 2. The results showed that the best chromatographic separation
253
of the four propiconazole stereoisomers could be achieved on the Chiralpak AD-3
254
column, with resolutions above 2.0 and relatively short retention times (Figure 2A).
255
Additionally, baseline resolution could be obtained on the Chiralpak IA-3 column, but
256
the smallest resolution under the optimal separation conditions was just above 1.6
257
(Figure 2E). In the case of the other two cellulose-based chiral columns, i.e.,
258
Chiralpak IB-3 and Chiralpak IC-3, only partial separation was obtained (Figure 2B
259
and Figure 2C), indicating an insufficient propiconazole resolution. Thus, the
260
Chiralcel AD-3 column was chosen in this study.
261
Chiralpak AD-3 and Chiralpak IA-3 are two types of amylose-based columns;
262
although both are based on the tris-(3,5-dimethylphenylcarbamate) of amylose (Figure
263
2A, Figure 2E), their linkage types are different. The former is a coated type, while
264
the latter is an immobilized type. Generally, the chiral recognition ability of the
265
immobilized polysaccharide-based chiral stationary phase is lower than that of the
266
corresponding coated chiral stationary phase under the same standard conditions.24, 25
267
Chiralpak IB-3 and Chiralpak IC-3 were based on the
268
tris-(3,5-dimethylphenylcarbamate) of cellulose and the
269
tris-(3,5-dichlorophenylcarbamate) of cellulose, respectively. Of the three
270
polysaccharide CSPs, amylose tris-(3,5-dimethylphenylcarbamate) has often exhibited - 13 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
271
excellent chiral resolution.26 This finding may be due to the difference of backbone
272
structures of the CSPs and their polar functional groups, by which different
273
preferences in their interaction with analytes occur.27, 28
274
Optimization of the mobile phase. In the SFC-MS/MS system, the main component
275
of the mobile phase was compressed liquid CO2. However, pure CO2 often could not
276
adequately elute the analytes, especially the polar analytes. Therefore, a certain
277
amount of an organic modifier was added to separate the propiconazole stereoisomers
278
on a Chiralcel AD-3 column. Comparative analysis assays concerning the type and the
279
proportion of organic modifier (acetonitrile, methanol, ethanol, and 2-propanol) were
280
conducted. The results showed that only ethanol or 2-propanol as the modifier could
281
achieve the baseline separation of the four propiconazole stereoisomers. However,
282
when 2-propanol was used, the retention time of each stereoisomer was delayed, and
283
the stereo-resolution was negatively affected by peak tailing (Figure 2D).
284
Furthermore, because of the lower content and higher viscosity of 2-propanol in the
285
mobile phase, the nebulization in the electrospray ionization source of the mass
286
spectrometer was often worse than when using ethanol. Comparatively, ethanol was
287
more conducive to the stereoisomeric separation of propiconazole on the Chiralcel
288
AD-3 column in terms of its excellent separation, short retention time, and good peak
289
shape. A pioneering study revealed that the four stereoisomers of propiconazole could
290
be separated on a Chiralcel AD column at 200 bar, 35 °C, and 2 mL/min. 19 However,
291
baseline separation of the four eluted peaks could not be achieved simultaneously
- 14 ACS Paragon Plus Environment
Page 14 of 40
Page 15 of 40
Journal of Agricultural and Food Chemistry
292
with ethanol as the modifier. Although good separation could be obtained with
293
2-propanol as the modifier, the retention times were too long (above 15 min).
294
As shown by the results, the organic modifier content in the mobile phase has a
295
considerable effect on chiral separation. When the ethanol content increased from 5%
296
to 11% (v/v), k' for the four stereoisomers decreased from 3.53, 4.47, 5.03, and 5.73 to
297
1.22, 1.47, 1.73, and 1.93, respectively. Simultaneously, the Rs values decreased
298
significantly, from 5.08, 2.09, and 2.16 to 2.45, 2.33, and 1.45. By comparison, a final
299
amount of 7% ethanol (v/v) was selected for its relatively better resolution and shorter
300
retention times.
301
In addition, the flow rate of the mobile phase was also investigated for the
302
separation of propiconazole stereoisomers. Short retention times and low resolution
303
with the increasing flow rate were observed. When the flow rate increased from 1.6 to
304
2.4 mL/min, k' decreased significantly from 3.17, 3.84, 4.42, and 4.90 to 1.64, 2.04,
305
2.39, and 2.69, while α increased from 1.21, 1.15, and 1.11 to 1.24, 1.17, and 1.13.
306
Meanwhile, Rs decreased from 3.66, 2.84, and 2.08 to 3.27, 2.44, and 1.85. The flow
307
rate of 2.0 mL/min, which gave rise to better resolutions and relatively centered
308
retention times, was selected for subsequent experiments.
309
Selecting the ABPR pressure and column temperature. The pressure of the
310
supercritical system influences the density of CO2 and alters the eluotropic strength of
311
the fluid.29, 30 The effect of the ABPR pressure of the convergence manager was
312
investigated by changing it from 1,800 to 2,600 psi at intervals of 200 psi. The ABPR
313
pressure had a large effect on the retention time but a minimal effect on the resolution - 15 ACS Paragon Plus Environment
Journal of Agricultural and Food Chemistry
314
of the propiconazole stereoisomers. k' decreased from 2.63, 3.23, 3.74, and 4.18 to
315
2.00, 2.47, 2.87, and 3.20 with the increase in ABPR pressure, while α values were
316
constant. Considering that lower pressure is a benefit to the usage lifetime of the
317
Chiralpak AD-3 column, 2,200 psi, a relatively lower ABPR pressure with better
318
resolutions, was selected for further study.
319
Column temperature is a complicated factor affecting chiral separation when
320
supercritical fluid is used as the mobile phase. On the one hand, with the increase in
321
temperature, the density and solvating power of CO2 decreases, leading to an increase
322
in retention time. On the other hand, high temperature increases the solubility of the
323
analytes, causing a decrease in retention time.31 In the current study, the effect of
324
column temperature on resolution was investigated for the propiconazole
325
stereoisomers at 26, 28, 30, 32, 34 and 36 °C. A Chiralpak AD-3 column was
326
employed with a flow rate of 2.0 mL/min and 7% ethanol as the mobile phase
327
modifier with the ABPR pressure at 2200 psi. The results showed that the temperature
328
had a relatively slight impact on the separation of the propiconazole stereoisomers.
329
Overall, a higher temperature was favorable to higher resolution in this study. With
330
the increase in temperature, the selectivity did not change, but k' increased from 2.19,
331
2.69, 3.13, and 3.51 to 2.39, 2.93, 3.37, and 3.78. Clearly, the first of the two listed
332
effects might dominate possibly due to the low percentage (0.05, Student’s paired t-test) was observed.
418
Stereoselective Degradation. Dissipation in wheat straw and grapes. Under field
419
conditions, concentrations of the four propiconazole stereoisomers in wheat straw and
420
grapes almost achieved a maximum 2 h after foliar application (Figure 4A and B) and
421
then decreased with time. Thus, the concentration of each stereoisomer at 2 h was - 20 ACS Paragon Plus Environment
Page 20 of 40
Page 21 of 40
Journal of Agricultural and Food Chemistry
422
regarded as the starting point of the regressive degradation equation. The degradation
423
of the propiconazole stereoisomers in wheat straw and grapes followed first-order
424
kinetics, with R2 in the range of 0.8255-0.9879. The respective half-lives of
425
(+)-propiconazole B, (-)-propiconazole B, (-)-propiconazole A, and (+)-propiconazole
426
A were 3.37, 5.01, 7.43, and 10.45 days in wheat straw, and 3.12, 2.39, 8.71, and 7.03
427
days in grapes. The half-lives of (±)-propiconazole B and (±)-propiconazole A in both
428
wheat straw and grapes were all significantly different (P