PITTCON 4:45 (981) Opto-Mechanical Design and Theoretical Studies of an Inter ferometer—O.W. VIDRINE. Analect Instruments. F. Ponce
Process Chemistry—FTIR, Near-IR, IR
Novel Separation Techniques
Thursday Afternoon, North Building, Lower Level, Room L3 R. Gagne, Presiding PPG Industries. Inc.
Thursday Afternoon. East Building, Main Level, Room 20W8 G.D. Dupre'Presiding Exxon Res. & Eng. Co.
1:30 (992) The Use of FTIR Analyzers in Production Plants for Quality Control Decision Making—M.C. GARRY, Nicolet Instrument Corporation, R.A. Derler
1 30 (982) Isolation of Polar Metabolites of Atrazine by Mixed-Mode Adsorption—M.S. MILLS, U.S. Geological Survey, WRD. EM. Thurman. R. Patel
1:50 (993) Application of Short-Wave Near-Infrared Spectroscopy—Τ OWEN. Hewlett-Packard GmbH, T. Klink, S. Bayerbach
1:50 (983) Purification of Immunoglobulins from Ascites Fluid Using Preparative Isoelectric Focusing—I. CARNE, Rainin Instrument Co.. Inc., R. Hatch
2:10 (994) The Design of FT-Near-IR Evanescent Fluid Absorption Fi ber Optic Sensor—T.B. COLIN, University of Iowa, M.A. Arnold, G.W. Small, W.C. Stwalley
2:10 (984) Resolution and Identification of Volatile Organics by Matrix Isolation and Purge & Trap-GC/MS Analysis—C.P. SHERMAN HSU, J.T, Baker. Inc.. B. Barr.P.A. Bouis 2:30 (985) Analytical Methods for Extraction of Metal-Porphyrins from Petroleum Crudes and Derivatives: A Perspective—N. MARQUEZ, Universidad deZulia, C. De La Cruz 2:50 (986) Quantitative, High Pressure Soxhlet Extraction—Κ M SCHOLSKY. J&W Scientific 3:10
RECESS
2:30 (995) The Application of NIR Spectroscopy and Principal Compo nent Analysis to the Identification of Pharmaceutical Materials—J. GRIFFIN, Ciba-Geigy AG, W. Kohn 2:50 (996) Use of FTIR/ATR Sensors for On-line Process control: Ap proximate Solution to the Calibration/Prediction Problems with Errors In the Independent Variables—J.C. ALBERTI, Sandia National Laboratory, W.M. Huang, J.A. Phillips 3:10
RECESS
3:25 (987) Whole Column Detection: Application to Preparative-Scale Liquid Chromatography—K.L. KELLY, University of Colorado. J.W. Birks
3:25 (997) Instrumental Analysis of Rapidly Changing Samples—R RACHLIS. Bran + Luebbe Analyzing Tech., Inc.. H. Mark
3:45 (988) True Countercurrent Chromatography-lts Preparative Ap plications in Natural Products Research—Y.W. LEE, Research Triangle Institute
3:45 (998) Process Control in the Petrochemical Industry Using NearInfrared Analysis—L. McDERMOTT, LT Industries, Inc.
4:05 (989) Centrifugal Partition Chromatography, Uses in Preparative Scale Separations—R. MENGES. University of Missouri-Rolla, D.W. Armstrong
4:05 (999) The Measurement of Control Parameters in the Sweetener Industry Using Near-Infrared Analysis—L. McDERMOTT, LT Industries, Inc.
4:25 (990) Efficient Countercurrent Chromatography for Studies on Secondary Metabolites in Natural Products and Clinical Samples—A K B0SE. Stevens Institute of Technology, M. Lee, T. Anoopkumar. S. Ganguly, E.F. Chou
4:25 (1000) Nemours & Co.
4:45 (991) Effect of Electrostatic and van der Waals Forces on the Capillary Hydrodyanmlc Fractionation of Colloidal Particles C.A. SILEBI, Lehigh University, M. Durali
Stack Gas Monitoring Using FTIR—J.T. CR0NIN. Ε Ι.du Pontde
4:45 (1001) On-line Analysis of Volatile Organic Compounds in Waste water Streams—P. CHEN, Fluid Data/Amscor, R. Spitler, L. Farley, G. Kucera
The Best-Kept Secret in pH/ISE Measurement Its no mystery to analysts in the water/wastewater treat ment business—Hach's systems for electrochemical analysis are convenient, reliable and accurate.
You won't have to become a detective to learn more. Just contact Hach and ask for literature 3205.
Now the word is out to analysts in other fields about an advanced, versatile, application-oriented meter that provides: •Six operational modes—pH. ion concentration, mV, relative mV, incremental methods, temperature • Linear and true non-linear ISE calibrations • Double standard addition, standard and analyte addition/subtraction • Dual-measurement channels •Computer interface • Programmable stability indicator Complete analysis packages are available for measuring pH. N O , , F . N a ' , K \ NH 3 + , CN /I , Ca 2 " or CI ,
Hach One™ Laboratory pH/ISE Meter$1495.00Made in U.S.A. Visit Hach at the Pittsburgh Conference, Booth 3817. Ask for a free, 700-page Water Analysis Handbook.
HACH
HACH COMPANY P.O. Box 389 Loveland, CO 80539 800-227-4224 Hach One is a Hach Company trademark
CIRCLE 78 ON READER SERVICE CARD
176 A · ANALYTICAL CHEMISTRY, VOL. 63, NO. 3, FEBRUARY 1, 1991