were received, the FDA evaluated each comment for its merit and how the specific suggested change would meet the Agency's need for ensuring the best possible data. In the pream­ ble of the final GLP regulations in the December 22,1978, Federal Register, the comments received by the Agency are each discussed with the Commis­ sioner's reason for accepting or reject­ ing each suggestion. Many suggestions were accepted. A critical one from the analytical aspect was that the material being safety tested can be "appro­ priately characterized" rather than identity, strength, quality, and purity being automatically specified. This critical change permits sound scientif­ ic judgment to be exercised in the characterization of the materials being tested. Because of the Agency, the final GLP's are more manageable, less cost­ ly, and still.meet the original purpose. Many of the details on exactly how the scientific work is to be conducted have been eliminated, and profession­ al judgment can replace detailed rules. This final GLP still meets the Agen­ cy's needs, but does not place an undue burden on the scientists in­ volved in assessing the safety of new chemicals. The final GLP regulations demonstrate the desire on the part of the Agency to work with those regulat­ ed to produce meaningful rules. With­ out this willingness to adopt scientific input, there would have been a manyfold increase in cost of safety testing. More importantly, the number of safe­ ty tests and the time required to com­ plete safety work would have de­ creased the number of new health products made available to the con­ sumer. The regulatory area continues to change, and there are many similar chances for scientific input to a gov­ ernmental agency. For example, the Environmental Protection Agency (EPA) will issue in the coming months their version of the GLP's covering safety studies for the materials they regulate. To avoid considerable confu­ sion, it is imperative that the EPA's rules be consistent with final GLP's from the FDA. Those to be regulated should carefully examine the EPA's proposed GLP rules and provide the EPA with written comments on unac­ ceptable aspects. Table I lists regula­ tory proposals or anticipated propos­ als that should be of interest to ana­ lytical scientists and deserve their input. References (1) William Horwitz, Anal. Chem., 50 (6), 521A (1978). (2) Robert M. Hodges, ibid., ρ 531Α. (3) R. A. Libby, ibid. (10), 575A (Sept. 1978).

The Standard For Glass Capillary Columns THE MOST STRINGENT QUALITY CONTROL: Less than 2% variation in bore diameter throughout the column means higher efficiency; consistent and precise coiling diameters mean less tangling and break­ age.

HIGHEST COLUMN TO COLUMN CONSISTENCY: Analytical results from one column, one day, can be compared to those on another column on another day.

MOST STABLE COATINGS: Our silicone coatings will even tolerate re­ peated direct water injection. No other column manufacturer will make this claim.

LOWEST BLEED RATE: Means the lowest baseline rise on temper­ ature programming and longer column life.

GUARANTEED PERFORMANCE: Each column is tested to insure perform­ ance as specified and a chromatogram w i t h all test conditions and calculations is included. We guarantee a minimum coat­ ing efficiency, not just plate numbers which can be manipulated w i t h minute changes in the inner bore dimension, test compound and test temperature. Available in .25 mm diameter and, for GC/MS, .35 mm diameter in extra low bleed silicone "phases."

USE THE COLUMN THE EXPERTS USE: GLASS CAPILLARY COLUMNS MADE BY ELVES IN THE USA AT

J&W SCIENTIFIC. INC. >PFC Λι Ι / ΐ Ν ί ;

IN MICH RiSOLUTION GAS CHROMATOGRAPHY

Currently Available Through: Supelco Inc., and Supelco S.A. Supelco Park, Bellefonte, PA 16823 For More Information Write: Supelco Inc. or J&W Scientific Inc., P.O. Box 216, Orangevale, CA 95662